Comfort. Description. Applications

Similar documents
Description. Applications

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Brasch Hazardous Location Unit Heaters

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

HLA Series Hazardous Location Fan Forced Unit Heater

Industrial Air Heaters

HLA Series Hazardous Location Fan Forced Unit Heater

Thermal Devices, Inc. Mount Airy, Maryland USA

Description. Applications

Ultra-Safe EXP Unit Heater

FX5 Series Explosion-Proof Electric Air Heaters

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

ULTRA-SAFE Explosion-proof Duct Heaters

LUH HORIZONTAL FAN-FORCED UNIT HEATER

FE1 Explosion-Proof Electric Air Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters

ULTRA-SAFE Explosion-proof Duct Heaters

Description. Construction

KUH. Horizontal Unit Heater. Applications. Description

CX1 ProVector Explosion-Proof Heaters

CXH-A Forced-Air Heater

CF1 ProVector Explosion-Proof Heaters

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

EXH Series Explosionproof Electric Air Heaters

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Explosion-Proof Forced Air Unit Heater - XGB

Explosion-Proof Forced Air Unit Heater - XGB

Electric Unit Heaters

COLD WEATHER PRODUCTS CATALOG

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

SUBMITTAL SCHEDULE & DATA

MAC-120HE-03 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

Chromalox PRECISION HEAT AND CONTROL. Cold Weather Electric Heat and Control Products

Circulation Heaters Selection Guidelines

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

ChromaStar. Comfort. Infra-Red Radiant Heaters. Description. Portable. Applications. Fixed Overhead. 1.5 to 13.5 kw. 5,118 to 46,062 BTU/Hr

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MACH N-407 Heat Pump Air-Cooled Chiller

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL INDOOR/OUTDOOR

Air-Cooled Global Chiller

Hazardous Area Portable Fan Heater The Bulldog

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

240 Series Unit Heater SameDay Shipping

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

X Series (Model B) Explosion Proof Heater

Circulation Heaters Selection Guidelines

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

5736 N. Michigan Road Indianapolis, IN 46228

HEAT. Industrial Ltd. Standard Products


5736 N. Michigan Road Indianapolis, IN 46228

Hazardous Area Portable Fan Heater The Bulldog

Owner s Manual. Electric Forced Air Heaters for Hazardous Locations. This manual covers the installation, maintenance, repair and replacement parts.

Powers Controls ET 134 Low Temperature Detection Thermostat

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

G /6000 BTU/Hr. 1172/1758 Watt

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

Explosion Proof Hazardous Location Roof Top A/C Units

MERIT SERIES Up Flow / Horizontal

Shipboard Electric Water Heater

Shipboard Electric Water Heater

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Hazardous Area Portable Fan Heater The Bulldog

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

CWA4 Chilled & Hot Water Fan Coil

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

MERIT Series R-410A - Upflow / Horizontal

Infrared Electric Heaters - General Product Information

VA G 052 S

HD3D Forced-Air Heater

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

STEAM/HOT WATER UNIT HEATERS

SECTION (15767) - UNIT HEATERS

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Tubular Industrial Process

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

EVLPF Series Compact Fluorescent

FX5 SD Series Electric Forced Air Heaters for Hazardous Locations

MERIT Series R-410A - Upflow / Horizontal

Screw Plug Immersion Heaters

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

N Volt 1800 BTU/Hr. 527 Watt

bring value to your space

Refer to page 9 for information regarding the Breeze TM AccuSpec Sizing and Selection Program

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Transcription:

Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary heating for comfort or freeze protection. Applications Sewage Treatment Plants Petrochemical Facilities Unattended Pumping Stations Chemical Storage and Handling Facilities Paint Storage Areas Grain Elevators Coal Preparation Plants Aircraft Servicing Areas Oil Refineries Areas Containing Metal Dusts Onshore and Offshore Oil and Gas Drilling Platforms Gas Turbine Enclosures Pipeline Metering Stations Standard Features Cabinet 14 gauge painted steel construction protects against damage and corrosion. Louvers Individually adjustable louvers provide targeted heat. Heat Exchanger Glycol filled, Bronz-Glow* coated steel provides a corrosion resistant means of efficient heat transfer. Motor Permanently lubricated, washdown, flameproof motor provides maintenance free operation. Built-In Controls Heavy duty magnetic contactors and low voltage transformer allows for quick and easy wiring. Enclosures Electrical enclosures are factory sealed, certified for hazardous locations and rated for IP ingress protected. Heating Element Rugged, seamless, copper elements protected with high temperature cutouts. Optional Features Thermostat Factory installed, unit mounted, corrosion resistant rated for 15 F to 140 F (-9 C to 0 C) Fan Only Switch Factory installed, unit mounted, corrosion resistant, rated for IP Disconnect Switch Factory installed, unit mounted, corrosion resistant, lockable Circuit Breaker Factory installed, 4V Shunt-trip with manual reset Pilot Lights Available for "Heat On", over temperature and motor overload F-1

Blower Heater (cont d.) Design Features General Power Ratings... to 35 kw Thermal Output... 10,00 to 119,40 Btu/hr Voltages, Europe... 40 to 90 Vac, 3 ph, 50/0 Hz Hazardous Location Classifications... ATEX: IIIG Exd IIB Temperature Codes... ATEX: T3 (39 F/00 C) Electromagnetic Compatibility... Directive 89/33/EEC/EMC Installation Maximum Mounting... 8 to 10ft (.4 to 3m) Height, Floor to normal when heat is required Bottom of Heater at floor level Ambient Temperature... -4 F (-0 C) min., 104 F (40 C) max. Optional Arctic design to -40 F (-40 C) min. available Operating Limits,500 ft (,8 m). Check Maximum Operational with local Chromalox sales Altitude Above office for recommendations Sea Level for higher elevations Protection High Limit... Manual reset quick-acting linear-type thermal cutout. Optional dual-automatic and manual reset. Pressure Relief... Pressure relief device Motor... Thermistor protection with motor overload relay Heat Exchanger General Description... Bronz-Glow*-coated carbon steel tubes with integral rolled aluminum find Core Material... Bronz-Glow*-coated carbon steel Heat Transfer Fluid... Propylene glycol (ethylene glycol available with Arctic design) Heating Element Assembly... Immersion heater assembly with seamless, copper sheathed heating elements Cabinet Construction... 14-gauge steel, polyester powder-coated. Optional type 31L stainless steel with or without epoxy paint. Fan Guard... Epoxy-coated steel Fasteners... Nickel-plated steel for corrosion resistance; cast aluminum (non copper alloy) Control Enclosure... IP cast aluminum Hanger Connections... Two()5/8 in.(1mm) UNC tapped holes Controls Control Circuit... Internally supplied 10 V (40 V on 90 V heaters). Optional 4 V internally supplied (N /A on 90 V heaters). Thermostat... 15 to 140 F (-9.4 to 18.3 C) & washdown (NEMA 4X & IP) Disconnect... Rotary-type unit or wall mountable washdown (NEMA 4X & IP) Fan Only Switch... Rotary-type unit or wall mountable & washdown (NEMA 4X & IP) Circuit Breaker w/ Shunt Trip... Manual reset, 4 V shunt-strip, control panel mounted Indicator Lights... Power On, heater overtempera- ture, or motor overload *Bronz-Glow is the registered trademark of Bronz-Glow Holdings, St. Augustine, FL. F-

Blower Heater (cont d.) Performance Data Heaters Operating on 0Hz Size (kw) Speed (RPM) Motor / Fan Fan Size In. (mm) Power hp (kw) Air Delivery cfm (m /min) Air Flow Horizontal Air Throw Air Velocity fpm (m/s) Temp Rise T Net Wt. lbs (kg) Weight Shipping Wt. lbs (kg) 3 1,00 1 (305) 1/ 00 (19.8) 8 (8.53) 890 (1) 14.5 135 () 15 (80) 5 1,00 1 (305) 1/ 00 (19.8) 8 (8.53) 890 (1) 4.1 135 () 15 (80).5 1,00 1 (305) 1/ 840 (3.8) 3 (9.5) 1,0 (38) 30. 135 () 15 (80) 10 1,00 1 (305) 1/ 840 (3.8) 3 (9.5) 1,05 (34) 40. 140 (4) 180 (8) 15 1,00 1 (40) 1/ 1,450 (41.1) 4 (14.33) 948 (89) 35 10 (3) 00 (91) 18 1,00 1 (40) 1/ 1,450 (41.1) 43 (13.1) 948 (89) 4 11 (3) 11 (9) 0 1,00 1 (40) 1/ 1,450 (41.1) 43 (13.1) 948 (89) 4. 11 (3) 11 (9) 5 1,00 0 (508) 1/,330 (5.9) 54 (1.5) 1,050 (30) 3.3 1 (98) 5 (11) 30 1,00 0 (508) 1/,330 (5.9) 54 (1.5) 1,050 (30) 43.5 1 (98) 5 (11) 33 1,00 0 (508) 1/,330 (5.9) 54 (1.5) 1,050 (30) 4.9 1 (98) 5 (11) 35 1,00 0 (508) 1/,330 (5.9) 54 (1.5) 1,050 (30) 50.8 1 (98) 5 (11) Heaters Operating on 50Hz Size (kw) Speed (RPM) Motor / Fan Fan Size In. (mm) Power hp (kw) Air Delivery cfm (m /min) Air Flow Horizontal Air Throw Air Velocity fpm (m/s) Temp Rise T Net Wt. lbs (kg) Weight Shipping Wt. lbs (kg) 3 1,500 1 (305) 1/ 18 (1.5) 8 (8.53) 85 (4) 1.5 135 () 15 (80) 5 1,500 1 (305) 1/ 18 (1.5) 8 (8.53) 85 (4).3 135 () 15 (80).5 1,500 1 (305) 1/ 41 (1) 3 (9.5) 950 (4.8) 34. 135 () 15 (80) 10 1,500 1 (305) 1/ 41 (1) 3 (9.5) 950 (4.8) 45. 140 (4) 180 (8) 15 1,500 1 (40) 1/ 1,9 (3.) 4 (14.33) 83 (4.) 39. 10 (3) 00 (91) 18 1,500 1 (40) 1/ 1,9 (3.) 43 (13.1) 83 (4.) 4. 11 (3) 11 (9) 0 1,500 1 (40) 1/ 1,9 (3.) 43 (13.1) 83 (4.) 5.9 11 (3) 11 (9) 5 1,500 0 (508) 1/,05 (58.) 54 (1.5) 9 (4.) 41.1 1 (98) 5 (11) 30 1,500 0 (508) 1/,05 (58.) 54 (1.5) 9 (4.) 49.3 1 (98) 5 (11) 33 1,500 0 (508) 1/,05 (58.) 54 (1.5) 9 (4.) 54.3 1 (98) 5 (11) 35 1,500 0 (508) 1/,05 (58.) 54 (1.5) 9 (4.) 5. 1 (98) 5 (11) F-3

Dimensions In. (mm) Comfort Blower Heater (cont d.) E D A B 11-1/1 (81) C Heater Dimensions In. (mm) Dimensions Heater A B C D E (Mtg. Holes) Disconnect Option -03 to -10 19-1/8 (488) 3-/8 (0) 1 (533) 3 (89) 13-5/8 (34) Add in. (18mm) to B dimension -03 to -10 5 (35) -/8 (08) 1 (533) 4-13/3 (11) 13-5/8 (34) -15 to -0 5 (35.0) -/8 (08) 1 (533) 4-13/3 (11) 1-5/8 (448) -5 to -35 3-5/39 (81.1) 31-/8 (810) 1- (55) 5-1/ (140) 1-5/8 (549) Mounting Kit Dimensions In. (mm) Model -03 to -10-10 to -9-5 to -35 Wall WMB-XD-1 PCN 0515 WMB-XD-1 PCN 0510 WMB-XD-0 PCN 0905 Ceiling (Hanging) HMK-XD-10 PCN 05195 HMK-XD-00 PCN 05195 HMK-XD-10 PCN 05195 Dimensions T (Min.) P Q R V W X Y Z* (15) (15) (15) 10 (54) 11-1/ (9) 14-1/ (38) 5-1/ (140) 5-1/8 (130) -3/8 (1) 4-9/1 (11) 4-9/1 (11) 4-9/1 (11) 3/3 3/3 3/3 9 (9) 13-1/3 (343) 18 (45) Ceiling Mounting Kit (HMK-XD) Simple and economical if adequate overhead structure exists. Requires 5/8" (15.8 mm) rod, cut and threaded. Wall Mounting Kit (HMK-XD) Ideal for use in buildings that have substantial walls. Arm only can also be bolted directly to structural steel. Wall Mounting Bracket Detail V W X Y T P Z Y R Q F-4

Blower Heater (cont d.) Ordering Information To Order Complete the Model Number using the Matrix Provided. Code Heating Element Rating (kw) 03 3 0 0 05 5 5 5 0.5 30 30 10 10 33 33 15 15 35 35 18 18 Code Heater Voltage 43 40 (3 ph only) 43 40 (3 ph only) 3 0 (3 ph only) 483 480 (3 ph only) 383 380 (3 ph only) 413 415 (3 ph only) 403 400 (3 ph only) 03 00 (3 ph only) 443 440 (3 ph only) 93 90 (3 ph only) Code Control Volts 30 4V 3* 10 V (Standard Control. See note below on 90 V heaters) Code Thermostat Option 00 Without Thermostat 40 Thermostat Code Heat Exchanger Fluid 1 Ethylene Glycol Groups C,D,E,F,G Propylene Glycol Groups C,D,E,F,G (Standard) Code High Limit Cutout Option H1 Redundant High Limit Cutouts (Automatic and Manual) Code Disconnect Option D1 Standard Disconnect D Disconnect Switch with 4 V Shunt Trip Code Pilot Light Option P1 Heat-On Pilot Light P Overtemperature Pilot Light P3 Heat-on and Overtemparature Pilot Lights P4 Heat-on, Overtemperature & Motor Fault Pilot Lights Code Fan Switch Option S1 Fan-only Switch Code Case C1 31L SST Case C Epoxy-Painted 31L SST Case Code Environment E1 Arctic Duty E High Altitude E3 Arctic Duty & High Altitude Code Special CE European Version (ATEX) CXH-XP -10 483 30 00 1 H1 D1 P1 S1 C1 E1 EP Typical Model Number Notes Standard with manual reset cutout Control Code 3 on 90V heaters indicates 40V control Heaters are not available with single phase voltage Artic duty design includes motor rated to -55 C and propylene glycol heat transfer fluid High altitude design includes special high limit cutout F-5