Duct Type Fan Coil Unit Air flow: 680~4590m 3 /h Cooling capacity: 3.7~.6kW
Duct Type Fan Coil Unit Duct Type Fan Coil Unit Air flow: 680~4590m 3 /h Cooling capacity: 3.7~.6kW Cabinet and concealed duct type fan coil unit are optional; Two-pipe system and four-pipe system are optional. Model Nomenclature FC - NFCI TH 4 - L face to the air outlet side L - Left connection, R - Right connection No mark - - pipe 4-row, 4-4 - pipe 3+-row Model Code : High-static Duct Type Unit NFCI - Horizontal concealed type NFCU - Horizontal cabinet type Normal Air Flow Rate:.7m 3 /h Climaveneta Fan Coil Unit
Product configuration Coil: Super Heat Transfer-Coils are made of seamless high quality copper tubes and hydrophilic aluminum fins. To ensure leak free and perfect contact for themost efficient heat transfer rate, the coils are expanded. Draining Panel: Excellent steel draining panel is formed by mould, no Leakage.It is wholly insulated by 7mm PE insulating foam on the outside to prevent any condensation or leakage. Casing: Good Appearance and Solid Construction Frame is made of high quality galvanized sheet steel,which has solid construction. Meanwhile, casing of open types is made of corrosion resistant treated steel plate. It is coated with heat hardened polyester based powder paint for better appearance. Blower: Quiet Operation -fan blades are designed with forware-curved blades and material is galvanized.the scroll is fixed to the side plates by means of biting. Motor: High Efficiency and Low Energy Consumption-Ball bearings are used to ensure longer life. The accurate alignment of the bearings and the use of rubber shock absorber guarantee the most smooth and quiet operation.
Duct Type Fan Coil Unit Technical data -pipe 3-row Air Flow (m 3 /h) Cooling Capacity (kw) Heating Capacity (kw) Fan Coil Motor Model H M L H M L H M Water Flow (m3/h)water L Pressure Drop (kpa) ESP (Pa) Type Quantity Type Quantity Power Supply(V / Ph / Hz) Insulation Class Power Input (W) Running Current 680 50 340 3.7 3. 5.5 4.4 3 0.635 3.6 6 88 0.4 Cooling Coil Conn. (in/out) 3/4 FPT 3/4 FPT 3/4 FPT 3/4 FPT 3/4 FPT 3/4 FPT 3/4 FPT 3/4 FPT 3/4 FPT 3/4 FPT 3/4 FPT 3/4 FPT Drain Pipe Noise Level (db(a)) Net Weight (kg) 5 44 33 850 638 45 4.3 3.5.6 6.5 5. 3.6 0.744 8. 6 0 0.5 5 45 34 FC-NFCITH/NFCUTH 600 00 765 50 4.9 4.9 7.5 5.9 4. 0.848.9 6 800 360 00 680 7.5 6. 4.5.3 8.9 6.3.303 0.8 8 000 700 75 850 9.3 7.5 5.6 3.9 7.7.605 5.7 03 00 040 530 00.4 9. 6.8 6.9 3.4 9.4.968 6. 380 785 90.8 0.4 7.7 9. 5. 0.6.0 3. 7 600 70 040 360 4.6.8 8.8. 7.5..5 7.8 800 3060 95 530 5.9.9 9.5 4. 9. 3.4.736 9 3 000 3 550 700 7.7 4.3 0.6 6.7. 4.8 3.036 8.8 7 centrifugal fan (forward-curved galvanized steel fan wheel) 43 0.7 5 47 35 0 0.9 5 5 45 3-speed single phase motor *. The above cooling capacity is under entering air temp 7ºC DB/9.5 ºC WB, chilled water inlet 7ºC and water temperature difference is 5ºC. *. The above heating capacity is under entering air temp ºC DB and heating water inelt temp 60ºC, water flow and air flow same as cooling mode. 3. The above noise level is tested under back ground(<7db(a)). 56. 5 5 56 78.3 5 56 70 AC φ-0v-50hz B 333.5 5 60 70 385.8 5 60 90 485. 5 6 90 573.6 5 66 98 4080 3060 040 0. 6.3. 30.7 4.3 7 3.456. 75 3.3 5 66 98 700 4590 3443 95.6 8.3 3.6 34.5 7.3 9. 3.886.7 0 860 3.9 5 68 0 3
Model FC-NFCITH/NFCUTH 600 800 000 00 600 800 000 700 Length Width Height Hole Air inlet/outlet A B C D E L W mm 550 550 60 60 60 60 670 670 670 85 85 85 000 000 00 00 60 60 60 35 35 35 35 350 350 450 860 860 860 035 035 35 35 435 435 435 435 435 450 450 50 50 50 50 570 570 570 675 675 675 850 850 050 050 50 50 50 50 50 85 85 85 40 40 40 40 75 75 35 35 35 4
Duct Type Fan Coil Unit Installation And User Manual.INSTALLATION Pay attention to maintain the unit properly. The turning parts inside should not collide.make sure there are no large floating debris into fan, motor or coil. Also make sure that the outlet side of a draining panel keeps 3 to 5 mm lower than the opposite side at least and water discharges well..air DUCT CONNECTION In order to restrict vibration transmitting use flexible duct on inlet/outlet of unit. 3.WATER CONNECTION Fix the connections by tightening the fan coil fitting with the wrench against wrench system. Remember that the torque should not exceed.5kg.m. Make sure the correct direction of water flow. The cooling/heating water shall go through the coil from the bottom (inlet) to the top (outlet). The installation of flexible connector is advised to restrict vibration transmitting. To control room tempera use a room sensor connected with 3-way or -way valve actuator as on the diagram. Ball valves should be installed to adtjuurset water flow rate or stop up the flow if needed. The drain pipe shall keep a slope to make draining water goes freely. All pipes and regulating parts shall be installed. When connection is finished a leak test must be applied. Normally the testing pressure is.5 times more than working pressure. 5
4.WIRING Make sure of the correct color when connecting wires. Make sure that the unit is grounded properly. Red Taminal black Low User side 3-speed switch Motor Brown Black White Medium High neutral 5.TEDT RUN After installation, carry out the test run before decorate the interior. 6.OPERATIOM In summer time the cooling water temperature shall not be lower than 5, otherwise the dew can destroy the surface of insulation and the interior will be damaged. In winter time the heating water temperature shall not exceed 65. If the unit does not work for a long period in winter time the water must be discharged from the coils if there are no any special sntifreeze components. Otherwise it will break coils. 7.MAINTENANCE In order to keep the normal air flow rate clean the filter and the coil permanently. Pay extra attention in case the unit has no cooling/ heating effect. 6
Climaveneta Italy: 3606 BASSANO DEL GRAPPA (VICENZA) ITALIA - VIA SARSON 57/c TEL. +39 / 044 509 (r.a.) - TELEFAX +39 / 044 509 509 E-mail:info@climaveneta.com http://www.climaveneta.com Climaveneta China: No,88 Baiyun Road Xinghuo Developing Zone,Shanghai,China Post Code:049 TEL: +86--57505566 FAX: +86--57505797 E-mail:info@climaveneta.com.cn http://www.climaveneta.com.cn Climaveneta Hongkong: Room 003,CCT Telecom Building, Wo Shing Street,Fotan,Shatin,N.T.,Hongkong TEL: +85-687755 FAX: +85--6873078 E-mail:info@climaveneta.com.cn http://www.climaveneta.com Climaveneta Vietnam: 6th Floor, Room 6.6B, Etown, 364 Cong Hoa Street, Ward 3, Tan Binh District, Hochiminh City TEL: +848 66 9966 FAX: +848 66 9977 E-mail: info@climaveneta.com.cn http:// www.climaveneta.com All specification and data are subject to change without notice B76 CCU/0-07-05 EN-SH