Smoke Detector and Siren. Manual

Similar documents
10 Year Smoke Detector and Siren

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

POP_ Smoke Detector

POP_ Smoke Detector

FIB_FGBS-001 Universal Binary Sensor

Devolo home Control Door/Window Contact MT 02648

SRT321 User and Installation Instructions

Instruction Manual Water Sensor

Mobeye CM2410 GSM fire alarm communicator

HSD-200Z Z-Wave Motion Sensor

Zigbee Smoke Sensor PSG03

SCS311 / SCS317 Installation Instructions

DCH-Z110/Z120. Function Compare DCH-Z110/DCH-Z120. Add to/remove from Z-Wave TM Network

Slim Multisensor PST02-A/B/C

Slim Multisensor PST02-A/B/C

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Operating Instructions Version 1.2

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

MOBILE CALL GSM Alarm System User s Manual

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Consultant Specification AGILE Wireless Fire Detection System

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ENGLISH. Recirculation with On-Demand Accessories User Guide 1

Always Connected. Always Covered. Siren DMS01. User Manual

USER MANUAL Mobeye ThermoGuard CM2200

External Wireless Sounder

PET IMMUNE PIR MOTION DETECTOR

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

SHARP. Multi Sensor User s Guide. Model: DN3G6JA069

Added password for IP setup page : Password must be in IP format!

Temporary wireless battery operated fire system from Channel Safety Systems

Instruction Manual Siren Alarm

SMART SMOKE DETECTOR

Z-Wave Network Inclusion/Exclusion/Reset

Intelligent Wireless GSM Alarm System

FieldServer Driver - Serial FS Notifier NCA

Instruction Manual Contact Sensor

1. Introduction. 2. Product overview

PIR sensor GR-302N GR SMART HOME

Instructions manual. By-alarm. By-alarm Manager software

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

abode Web app Functionality

GSM RFID VOICE Alarm System

D3D Wi-Fi GSM Smart Alarm System -User Manual

Ref.1067/032 Ref.1067/042

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

2G & 3G GSM Portable PIR Alarm

AG HOME ALARM Quick Start Guide

User Manual (LS-GSM-006)

status AW1 Plus WiFi Alarm System User Manual

S3 Sim Secual Alarm system with GSM transmitter

Integration Test Plan

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

SMOKE User Manual. NE v2.0

FCD-wire Contents. List of Figures

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Fire Command Keypad. XR5 User s Guide

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

1. Functions of GPS locator ETLOC-30S 3

Door/Window Sensor Installation Instructions

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Advisor Advanced User Guide

Radio fire warning panel SRC 3000

Elderly Care Alarm System

Tebis application software

ELT-KLED EliteSuite LED Keypad Installation Manual

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL

G34 AU1B (External Ultrasonic Sensor) Version 3

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

Halton SAFE / 7.14 user guide and installation instructions

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

Wireless Keypad GKP-S8M


IX30 - Z-Wave PIR Detector User Guide

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Operating instructions

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

SC-F3G User Manual 1.0

Yale Locks. Z-Wave+ System Integrators Guide. Yale nextouch Sectional Mortise Keypad Lock NTM 610/615/620/625/630/635/640/645

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Ion Gateway Cellular Gateway and Wireless Sensors

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Installation and Operation Manual. Wireless Indoor Strobe

AXI LED USER MANUAL (REV. 1.0)

Integrated Security Solutions

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

U ser's Guide PC6010

Connections, displays and operating elements C D E G H. Installing the control unit

Version 1.03 January-2002 USER S MANUAL

Laptop / PC Programming Manual

2000 Series. Program Entry Guide. Control Panels

Transcription:

Smoke Detector and Siren Manual 004001

Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device... 4 Node Information Frame... 4 Associations... 4 Configuration Parameters... 4 Command Classes... 5 Technical Data... 6 Explanation of Z-Wave specific terms... 6 Disposal Guidelines... 6 Support... 6 Quick Start This device is a combination of a Z-Wave Sensor (Smoke) and a Z-Wave Actuator (Siren). Pushing the internal button for 1 sec. includes and excludes the device. The device is either powered by battery or can be powered by an optional external power supply. It supports secure communication and will automatically recognize other smoke sensors sharing alarm messages to cover the whole home. Please refer to the following chapters for detailed information about all aspects of the product s usage. Product Description This product consists of a standard photo electric smoke detector with a pluggable Z-Wave wireless interface module. The smoke detector will also work as a stand alone product and is certified by VdS according to DIN EN 14604. The smoke chamber of the detector has a stainless steel reel with antistatic plastic chamber. A button allows on-device test of smoke chamber, electronics and battery. The device also offers a built-in self test and an electronic smoke chamber test to avoid the use of test aerosol. A low battery warning will last for 30 days but full function of the detector is guaranteed during this time. The Z-Wave module allows to report the smoke and low battery alarm wirelessly to a central controller. The detector can also be used as a wireless siren for alarm system or other applications. The wireless module is operated by the 9V battery of the smoke detector. An optional external power supply allows external powering the unit. According to VdS 3515 (smoke detectors with wireless communication) this device will automatically send alarm signals to all other POPP smoke detectors to turn on their siren. The same time all POPP smoke detectors will further relay the alarm signals to any other detectors in wireless range. This function ensures that all smoke detectors will issue noise if one of them detected a smoke. 2

Installation Guidelines Please refer to the installation manual of the smoke detector base device on where and how to mount the device. The installation guideline follows the European Norm EN 14676. Remove the bracket from the detector main unit by rotating it counter-clockwise. Place the bracket where you are going to install the detector. In each of keyhole slots, draw a mark to locate plastic anchor and screw. Using a 3/16-inch (5mm) drill bit, drills two holes at the marks and insert plastic anchor, and attached the bracket by using the screws. Plug the wireless module into the base device so that the three pins (4) in the center connect to the wireless interface. The battery compartment must be accessible. Open the battery compartment (1) to activate the battery, and then close the cover. The optional external power supply will connect to the connector (5). The internal battery must stay inside the detector even when the external power supply is connected. Mount the smoke detector to the mounting ring. Make sure the hooks of the detector are placed between the hook and the twist stopper (2) of the mounting base (arrows in image below). Then turn about 15 % clockwise. (Hint: If the detector hook is not placed right between the two mounting ring structures the detector can t be mounted to the ring). (1) Battery Compartment (2) Twist Stopper (3) Function Button (4) Connection Pins (5) Connector Box Behavior within the Z-Wave Network On factory default the device does not belong to any Z-Wave network. The device needs to join an existing wireless network to communicate with the devices of this network. This process is called Inclusion. Devices can also leave a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller will be turned into exclusion respective inclusion mode. 3

Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave the network. Leaving the network i.e. being excluded sets the device back to factory default. If the device already belongs to a network, follow the exclusion process before including it in your network. Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to be reset first. A simple click on the button of the wireless module (3) will include the device. Keeping the button (3) pressed for 2 seconds will force the device to be included without application level security. Single click or 2 seconds hold will exclude the device. A blinking LED indicates when the device is in inclusion or exclusion pending status. Operating the Device In case smoke is detected by the smoke detector the device will sound, the red LED will blink and the wireless module will issue a Z-Wave alarm command to the main controller and other associated devices. A low battery will be indicated on short siren noise plus the Z-Wave controller will be informed using Battery Low warning commands. Note: All communication of the wireless module is performed with application level security if the device was included securely and all communication partners support secure communication as well. In case a non-secure device is associated for switching on smoke alarm, the smoke detector will detect this and change its communication style with this very device to non-secure. This process happens one time and will take about 20 seconds. This delay will happen on first communication only. The siren can be used for other alarm indication. For this reason the device will be shown at graphical user interface as a simple on/off switch. Turning on this switch start the siren, turning it off will stop the noise. The generic siren alarm has a different acoustic pattern than the permanent sound caused by smoke. The configuration parameters 1 and 2 define the style of the sound. Wireless Alarm Meshing The wireless meshing is performed by secure exchange of alarm commands among all wireless POPP smoke detectors. In case an alarm (smoke or battery) is issued by one device, this very device will broadcast a respective alarm (using Alarm CC V2 encapsulated into security wrapper if applied) to all devices in range. Every device that receives an alarm command and did not receive an alarm within the last 10 seconds will broadcast the same alarm command. Using this algorithm every POPP smoke sensor will also indicate an alarm within few seconds. It is possible to wirelessly turn off the siren on all repeating smoke detectors but not on the detector that originally sent the alarm. You must find and remove the reason for the smoke detector to buzz. Factory Reset To reset the device keep the button pushed for 10 seconds. After 5 seconds the LED starts flashing and after another 5 seconds there is a short beep signaling the successful reset back to factory defaults. Node Information Frame The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out a Node Information Frame. Once included a simple click on button (3) will issue a Node Information Frame. Associations A Z-Wave device controls other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers,...). In case the event happens all devices stored in the respective association group will receive a common wireless command. Configuration Parameters Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features. 4

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256. For example: to set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too. Siren alarm sequence interval (Parameter number 1, Size 1) The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds. 3-129 Seconds (default 10) Siren alarm tone length (Parameter number 2, Size 1) The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. 3-129 Seconds (default 10) Value of On-Command (Parameter number 3, Size 1) 0-99 (Default 99) Value of Off-Command (Parameter number 4, Size 1) 0-99 (Default 0) Status of automated meshing of smoke alarms (Parameter number 5, Size 1) This smoke detector can automatically inform other smoke detectors of same type about smoke alarms. They will then also turn on the siren. This function is a requirement of wireless networked smoke detectors. 0 Inactive 1 Active (default) Status of automated meshing of battery alarms (Parameter number 6, Size 1) This smoke detector can automatically inform other smoke detectors of same type about battery alarms. They will then also turn on the siren. This function is a requirement of wireless networked smoke detectors. 0 Inactive 1 Active (default) Command Classes Supported command classes BASIC Version 1 BINARY SWITCH Version 1 BINARY SENSOR Version 2 ASSOCIATION GROUP Version 1 DEVICE RESET LOCALLY Version 1 Z-WAVE PLUS INFORMATION Version 2 CONFIGURATION Version 1 ALARM Version 4 MANUFACTURER SPECIFIC Version 1 POWERLEVEL Version 1 5

BATTERY Version 1 ASSOCIATION Version 2 VERSION Version 2 SECURITY Version 1 Controlled command classes BASIC Version 1 SECURITY Version 1 Technical Data IP Rating IP 20, VdS-Number: C208090, CPD Number: 0789-CPD-20474 Battery Type 1 * 9 V Battery Frequency 868.42 MHz (SRD Band) Wireless Range Up to 100 m outside, on average up to 20 m inside buildings Explorer Frame Support No Device Type Slave with routing capabilities Generic Device Class Alarm sensor Routing No FLiRS Yes Firmware Version 0.48 Explanation of Z-Wave specific terms Controller is a Z-Wave device with capabilities to manage the network. Controllers are typically gateways, remote controls or battery operated wall controllers. Slave is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls. Primary Controller is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network. Inclusion is the process of bringing new Z-Wave devices into a network. Exclusion is the process of removing Z-Wave devices from the network. Association is a control relationship between a controlling device and a controlled device. Wake up Notification is a special wireless message issued by a Z-Wave device to announce that is able to communicate. Node Information Frame is a special wireless message issued by a Z-Wave device to announce its capabilities and functions. Disposal Guidelines The product contains batteries. Please remove the batteries when the device is not used. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging health and well-being. Support Should you encounter any problem, please give us an opportunity to address it before returning this product. Most questions regarding Z-Wave wireless communication standard can be answered through the international community at www.z-wave.info. If your question can t be answered there, please contact us by email: info@popp.eu 6

2015 POPP & Co. While the information in this manual has been compiled with great care, it may not be deemed an assurance of product characteristics. Popp & Co. shall be liable only to the degree specified in the terms of sale and delivery. The reproduction and distribution of the documentation and software supplied with this product and the use of its contents is subject to written authorization from Popp & Co. We reserve the right to make any alterations that arise as the result of technical development. Phone: +44 (0) 20 7419 5726 email: info@popp.eu Web: www.popp.eu 8