Operating Instructions

Similar documents
Operating Instructions

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Engineering Guideline. pac- Carriers Type Universal

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Wideband Optical Couplers

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

MicroCoat Flow Guard Operating Manual

OPTIBAR DP 7060 Supplementary Instructions

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Premier External TD. Installation Manual INS352-3

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

PEPPERL+FUCHS GmbH

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Operating Instruction OI/TSC400-EN. SensyTemp TSC400 Industrial thermometer. For plug-in connection For screw-in connection For surface measurement

HEP Tech Co., Ltd. Company Profile

INSTRUCTION MANUAL (ATEX / IECEx)

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Flameproof Manual Call Points

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

Integrated IR Datasheet

Instrumentation Products and Applications

OPTIWAVE X500 Supplementary Instructions

Certificate of Compliance

Features. Figure 1. Recommended Application

SCHMIDT LED Measured Value Display MD Instructions for Use

Annubar Flowmeter Series

ETH1000-MKII. User manual

SF100 User Manual Version 1.0

Inductive slot sensor

SONAR PROCESS MONITORING SYSTEM SUPPLEMENT FOR ATEX CLASS I, ZONE 2 SAFETY

Certificate of Compliance

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

HRX Technical Manual. Version 1.2

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Rosemount 3490 Series


DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

AND INSTALLATION MANUAL

HRX3000. Technical Manual

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Record of Amendments. Version Date Amendment Section/page affected

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Installation and Operating Instruction

Earth-Rite II PLUS Static Earthing System

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

Installation Manual. Premier IXP-W INS538

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Operating Manual MS220DA

Installation Manual Premier Elite IXP-W

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Gas cylinder scale Model GCS-1

INSTRUCTION & SERVICE MANUAL

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Technical Data. Dimensions

USER MANUAL DIAGNOSTIC MODULE

Smart BUS (S-BUS) Home Automation System Simplified Specification

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Insulation fault evaluator EDS460-DG

Translation of the assembly instructions with operating instructions and technical appendix

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

Owner & Operator s Manual. Table of Contents

Snifter ATEX22 VERSION. User Manual. Distributor

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

PQS performance specification

PROCESSING UNIT II V Hz V Hz. Table of Contents

Indoor/outdoor resistance thermometer Model TR60

Model 144H. Product Data Sheet , Rev DB February Content

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Technical Data. Dimensions

Operating Instructions

2 WOW MOP COMPONENTS. Spray Button Power Button Nozzle. Pad Attach (Shadowed Area) Handle. Reservoir. Base

RT FLOW RATE TOTALISER

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

Dräger Polytron 7000 Fixed gas detector

Transcription:

Operating Instructions ProVicom MT-65, MT-125 R. STAHL HMI Systems GMBH Im Gewerbegebiet Pesch 14 50767 Köln Version 1.7 Issue: 21.07.2008 R. STAHL HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008 Page 1 of 15

Preface Operating Instructions ProVicom Table of contents Description Page 1 Preface 3 2 Provicom MT-65, MT-125 3 2.1 Device function 3 2.2 Product identification 4 2.2.1 For Zone 2 4 2.2.1.1 Identification number 4 2.2.2 For Zone 22 5 2.2.2.1 Product identification for MT-65 / MT-125 5 2.3 Special conditions 6 2.3.1 Zone 2 6 2.3.2 Zone 22 6 2.4 Warnings / notes 6 2.4.1.1 Note concerning use in Zone 22 6 2.5 Power supply 7 2.6 Type code 7 3 Installation and operation 8 3.1 General information 8 3.2 Installation in Zone 2 and Zone 22 8 3.3 MT-65, MT-125 8 4 Application 8 5 Assembly and disassembly 9 5.1 General information 9 5.2 MT-65, MT-125 9 5.3 Cut-out MT-xxx 9 6 Operation 10 6.1 Connections MT-xxx 10 6.2 Dip switch settings S1 and S3 11 7 Maintenance, service 12 7.1 Servicing 12 8 Troubleshooting 12 9 Disposal 13 9.1.1 ROHS directive 2002/95/EC 13 9.1.2 China ROHS 13 10 Certificates 14 10.1 Provicom MT-65, MT-125 14 10.1.1 Declaration of EC conformity 14 11 Release notes 15 Page 2 of 15 R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008

Operating Instructions ProVicom Preface 1 Preface These operating instructions also cover Ex-relevant aspects. 2 Provicom MT-65, MT-125 2.1 Device function The MT-65 and MT-125 operator interfaces are intelligent display and operating devices with text or graphic display for use in hazardous environments of zones 2 and 22 according to ATEX guideline 94/9/EC. The easy and simple functions of the MT-65 guarantee less configuration time for your application and reduce the workload of your PLC. The MT-125 operator interface offers many different styles of graphic display. Its many integrated functions also reduce the workload of your PLC. LCD monochrome graphic display, 240x64 dot resolution (MT-65), 240x128 dot resolution (MT-125) LED (MT-65) or CFL (MT-125) backlight Keyboard: extended 10 block MT-65 16 blank function keys that can be customised, 4 softkeys MT-125 12 blank function keys that can be customized, 4 set function keys, 8 soft keys Winbond W77IC32 processor, 22 MHz Program memory 512 kbyte RAM, data memory 512 kbyte RAM (with 64 kbyte boot part), main memory 128 kbyte RAM RS-232-C programming and printer interface Either RS-232, RS-422 or RS-485 communication interface 2nd serial interface: optional Profibus DP or MPI module Reader interface via module if required MT-65 temperature range: 20... +70 C MT-125 temperature range: 10... +60 C 24V DC power supply with reverse voltage protection MT-65 4 freely controllable LEDs and 16 function keys with LEDs in the frontplate MT-125 4 freely controllable LEDs and 12 function keys with LEDs in the frontplate Real time clock and data retention capacitor are buffered. R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008 Page 3 of 15

Provicom MT-65, MT-125 Operating Instructions ProVicom 2.2 Product identification The operator interfaces may only be installed according to the specifications on the type plate. 2.2.1 For Zone 2 Manufacturer: Type code: Ex classification: R.STAHL HMI Systems GMBH MT-65 / MT-125 MT-65: e II 3 G Ex na II T4 X -20 C Ta +70 C MT-125: e II 3 G Ex na II T4 X -10 C Ta +60 C 2.2.1.1 Identification number Id. number / description: e II 3 G Ex na II T4 X -20 C Ta +70 C Ambient temperature Note special conditions Temperature class 4 (135 C) Gas group: Application in groups A, B and C Non-transmitting device Type of protection normal operation Surrounded by gas Device category 3 (normal protection type) Device group II (for all devices NOT used underground or in mines and thus NOT surrounded by mine gas or flammable dust particles) Page 4 of 15 R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008

Operating Instructions ProVicom Provicom MT-65, MT-125 2.2.2 For Zone 22 Non-conductive dust Manufacturer: R. STAHL HMI Systems GmbH Type code: MT-65 Ex classification: e II 3 D EEx IP65 T85 C X -20 C Ta +70 C e II 3 D EEx IP65 T65 C X -20 C Ta +50 C Type code: MT-125 Ex classification: e II 3 D EEx IP65 T75 C X -10 C Ta +60 C e II 3 D EEx IP65 T65 C X -10 C Ta +50 C 2.2.2.1 Product identification for MT-65 / MT-125 Product identification e II 3 D EEx IP65 T85 C X -20 C Ta +70 C Ambient temperature Note special conditions Maximum surface temperature Protection against dust ingress (IP6X) Surrounded by non-conductive dust Device category 3 (normal protection type) Device group II (for all devices NOT used underground or in mines and thus NOT surrounded by mine gas or flammable dust particles) Note concerning Zone 22: MT-65: When the device is in operation in an ambient temperature range of Ta = -20 C to +70 C, the surface temperature will not exceed +85 C. When the device is in operation in an ambient temperature range of Ta = -20 C to +50 C, the surface temperature will not exceed +65 C. MT-125: When the device is in operation in an ambient temperature range of Ta = -10 C to +60 C, the surface temperature will not exceed +75 C. When the device is in operation in an ambient temperature range of Ta = -10 C to +50 C, the surface temperature will not exceed +65 C. R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008 Page 5 of 15

Provicom MT-65, MT-125 Operating Instructions ProVicom 2.3 Special conditions 2.3.1 Zone 2 1. This device is classified as a non-sparking apparatus with low power consumption. 2. The device housing must be of at least protection type IP54 at the point of assembly. 3. The devices must not be exposed to direct sunlight permanently. 4. The error output (relay contact) must NOT be connected. 2.3.2 Zone 22 The device housing must adhere to the EN 50281 requirements (such as the type 8146 or 8125 housings by R. STAHL Schaltgeräte GmbH). 2.4 Warnings / notes Warning! The error output (relay contact) must NOT be connected if the operator interfaces are installed in zone 2! Warning! Do not open device when switched on Warning! Do not remove fuse when device is switched on Warning! Do not remove connector when device is switched on Note: External leads must not be connected under strain 2.4.1.1 Note concerning use in Zone 22 Note: During assembly and operation of the operator interface electrostatic surface voltages must not exceed those caused by manual rubbing. Page 6 of 15 R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008

Operating Instructions ProVicom Provicom MT-65, MT-125 2.5 Power supply Operator interface MT-65 MT-125 2.6 Type code Power supply Current consumption Minimum Nominal voltage Maximum Maximum 19,2 VDC 24 VDC 28,8 VDC 105 ma 215 ma Type code: Provicom MT-xxx 65 / 125 Product type: Version MT-xxx-RS232 MT-xxx-RS422 MT-xxx- RS422-DP MT-xxx- RS422-MPI MT-xxx-RS MT-xxx-WCR Description Type with RS-232 interface RS-422 interface RS-422 and Profibus-DP interface RS-422 and MPI interface RS interface for barcode or proximity reader WCR interface for Wiegand Effect reader R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_ en_1_7.doc / 21.07.2008 Page 7 of 15

Installation and operation Operating Instructions ProVicom 3 Installation and operation 3.1 General information Electrical installations are subject to the relevant regulations for installation and operation. 3.2 Installation in Zone 2 and Zone 22 The users of electrical installations in hazardous environments must ensure that the equipment is kept in proper condition, is operated according to instructions and that maintenance and repairs are carried out. (RL 1999/92/EC, RL 94/9EC, IEC/EN 60079-14 are some of the regulations that apply). However, any repairs should always be carried out by the manufacturer. 3.3 MT-65, MT-125 The operator interfaces may be installed in zones 2 and 22 (non-conductive dusts). The devices are constructed according to protection type IP65 and must be protected accordingly from adverse environmental conditions such as splashed water or dirt exceeding pollution degree 2. Users must adhere to the Special Conditions. Also of importance are the authorized electrical operating values. The external PA/l must be connected. The PA-connector had to be connected to the equipotential bonding system. A connection is provided on the back of the terminal housing for this purpose. The PA-connector must be connected to the equipotential bonding conductor of the hazardous area. 4 Application The devices may only be used for the purposes detailed above and in accordance with current regulations; otherwise, the manufacturer s warranty shall become null and void! In case of incorrect or unauthorised use or non-compliance with the instructions in this manual the manufacturer s warranty will become null and void! No changes may be made to the devices or their components that compromise explosion protection. The devices may only be installed and operated in an undamaged, dry and clean condition. Page 8 of 15 R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008

Operating Instructions ProVicom Assembly and disassembly 5 Assembly and disassembly 5.1 General information Assembly and disassembly are subject to general technical rules. Additional, specific safety regulations apply to electronic and pneumatic installations. In Germany, for example, these include the BGI 547 (Information on and principles of workplace safety and health issued by the Government Safety Association). 5.2 MT-65, MT-125 When installing the device, particular care shall be taken that: the device has been properly installed according to instructions, the device is undamaged, all screws are tightened fast, the device s external bonding terminal is properly connected to the exponential bonding system at its place of use. 5.3 Cut-out MT-xxx Make a cut-out with the following dimensions: Device Width Height Installation depth Material thickness MT-65 275.0 ± 0.5 mm 131.0 ± 0.5 mm max. 80 mm up to 10 mm MT-125 300.0 ± 0.5 mm 180.0 ± 0.5 mm max. 80 mm up to 10 mm R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008 Page 9 of 15

Operation Operating Instructions ProVicom 6 Operation 6.1 Connections MT-xxx Plug Pin Definition Connection X1 1 Power supply operator interface + 24V Power supply 2 N.C. * of operator 3 Power supply operator interface GND interface X2 1 N.C. * Programming and 2 RxD Printer interface 3 TxD RS-232 4 N.C. * 5 GND 6 CTS X3 1 Relay contact Error output ** 2 Relay contact X4 RS-232 RS-422 / RS-485 1 N.C. * N.C. * 2 TxD N.C. * 3 RxD TxD-B 4 N.C. * RxD-B 5 GND N.C. * 6 N.C. * RxD-A 7 CTS N.C. * 8 RTS N.C. * 9 N.C. * TxD-A Communication interface RS-232 or RS-422/485 * Not Connected ** Warning: The error output (relay contact) must NOT be connected if the operator interfaces are installed in zone 2. X14 Plug Pin Definition Connection Version 3 RxD/TxD-P Communication L2DP 4 RTS Profibus-DP 5 M5V2 6 P5V2 8 RxD/TxD-N Version MPI 3 RxD/TxD-P 4 RTS/AS 5 GND 6 P5V2 8 RxD/TxD-N 9 RTS PG Communication MPI Page 10 of 15 R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008

Operating Instructions ProVicom Operation 6.2 Dip switch settings S1 and S3 S1.1 S1.2 S1.3 S1.4 S1.5 S1.6 S1.7 S1.8 Definition on Configuration menu released / activated on Delete text memory X Reserve off off off off off on off off Standard settings S3.1 S3.2 S3.3 S3.4 S3.5 S3.6 Definition on off RS-232 off on RS-422/RS-485 RS-4xx RxD on on Terminating bus resistor and termination switched on RS-4xx RxD off off Terminating bus resistor and termination switched off RS-4xx TxD on on Terminating bus resistor and termination switched on RS-4xx TxD off off Terminating bus resistor and termination switched off R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008 Page 11 of 15

Maintenance, service Operating Instructions ProVicom 7 Maintenance, service Because the transmission of the devices remains reliable and stable over long periods of time, regular adjustments are not required. Only original parts provided by the manufacturer must be used. Fuses may only be replaced by equivalent fuse types. System maintenance should focus on the following: a. Seal wear b. Monitor damage c. All screws are tightened fast d. All cables and lines are properly connected and undamaged Note: Associated equipment is subject to maintenance, service and testing according to guidelines 1999/92/EC, IEC 60079-19 and EN 60079-17 as well as EN 50281-1-2 (Zone 22)! 7.1 Servicing In accordance with IEC 60079-19 and EN 60079-17, operators of electric plants in hazardous areas are obliged to have them serviced by qualified electricians. 8 Troubleshooting Devices operated in hazardous areas must not be modified. Repairs may only be carried out by qualified, authorized staff specially trained for this purpose. Repairs may only be carried out by specially trained staff who are familiar with all basic conditions of the applicable user regulations and if requested have been authorized by the manufacturer. Page 12 of 15 R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008

Operating Instructions ProVicom Disposal 9 Disposal Disposal of packaging and used parts is subject to regulations valid in whichever country the device has been installed. The disposal of equipment sold after August 13 th, 2005, and installed in countries under the jurisdiction of the EU is governed by directive 2002/96/EC on waste electrical and electronic equipment (WEEE). Under this directive, operator interfaces are classified as part of category 9 (monitoring and control instruments). We shall take back our equipment according to our General Terms and Conditions. 9.1.1 ROHS directive 2002/95/EC The prohibition of hazardous substances as detailed in directive 2002/95/EC on the restriction of the use of certain hazardous substances (ROHS) does not apply to electronic equipment of categories 8 and 9, and is therefore not applicable to the equipment described in these operating instructions. 9.1.2 China ROHS According to a new administrative rule introduced in China 01.03.2007 all devices containing hazardous substances must be labelled accordingly. The following applies to the MT-65 / MT-125 operator interfaces: Names and Contents of Toxic or Hazardous Substances or Elements Part Name Lead Toxic or hazardous Substances and Elements Mercury Cadmium Hexavalenbrominated Poly- Chromium biphenyls (Hg) (Cd) (Cr (VI)) (PBB) Polybrominated diphenyl ethers (PBDE) (Pb) Housing O O O O O O Display O O O O O O all PCBs X O O O O O Misc. O O O O O O O X Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006. Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006. R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008 Page 13 of 15

Certificates Operating Instructions ProVicom 10 Certificates 10.1 Provicom MT-65, MT-125 10.1.1 Declaration of EC conformity Page 14 of 15 R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008

Operating Instructions ProVicom Release notes 11 Release notes Starting with the version 1.7 of these operating instruction the chapter "Release notes" is implemented. In this chapter you can find the respective changes which was done regarding this document version. Version 1.7 Changing the marking of the operator interfaces according to ATEX Replacement of EC - Declaration of Conformity Changing of the definition from the type code to the actual one Changing information to BGI 547 Formal improvement R. Stahl HMI Systems GmbH / OperatingInstruction_Provicom_Falcon_en_1_7.doc / 21.07.2008 Page 15 of 15