Daikin McQuay. Roofpak Evaporative Condensing Units. RPE, RDE Tons Vintage C. Replacement Parts List No Revision K 07/2016

Similar documents
McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

Air Cooled Scroll Compressor Condensing Unit

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

MEA. Self-contained Air Conditioning System. Installation and Maintenance. Type SWT C Vintage Sizes 18 thru 40. Group: Applied Systems

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

Installation and Maintenance Manual IM 988-1

RoofPak Singlezone Roof Mounted Heating and Cooling Units

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC)

RoofPak Singlezone Roof Mounted Heating and Cooling Units

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

RoofPak Applied Rooftop Systems Air Handler

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Installation and Maintenance Manual IM 893-6

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

AIR HANDLER DESIGN WORK SHEET

VariCool VAV Engineering Guide

RoofPak Singlezone Roof Mounted Heating and Cooling Units

Gas-Fired Indoor and Outdoor Duct Furnaces

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

RoofPak Singlezone Roof Mounted Heating and Cooling Units

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Installation Manual IM

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

MEA. Self-Contained Air Conditioning System. Installation and Maintenance. Type SWP Vintage Sizes 18 through 95, 105. Group: Applied Systems

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

Submittal Summary Page

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

48PGD/E/F/L/M/N PG20-28

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

RoofPak Applied Rooftop Systems

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

DCG Commercial. Submittal Data Form

Direct Fired Heater Model AD Specification

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

REPLACEMENT PARTS LIST

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

VertiCool Aurora Engineering Guide

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

Water-Cooled Self-Contained Units

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A

Modular Supply Make-Up Air Unit

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

RGE 13 A T - 1 A

Catalog RoofPak Applied Rooftop Systems with Energy Recovery Wheels

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62)

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Self-Contained Air Conditioning System

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

SECTION ROOFTOP REPLACEMENT AIR UNITS

SKYPAK II, 3 Ton Series, gives you a

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

SKYPAK II Heating & Cooling Self Contained Packages

Advance Release September 2009

Product Data. Features/Benefits. 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel. 6 to 35 Nominal Tons

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

RQ SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

TYPICAL CPA SPECIFICATIONS

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

Transcription:

Replacement Parts List No. 70009400 Revision K 07/06 Daikin McQuay Roofpak Evaporative Condensing Units RPE, RDE 076-50 Tons Vintage C To find your Daikin Applied parts distributor, call -800-377-787 or visit www.daikinapplied.com

Contents Parts List Revision History... 6 Nomenclature & Unit Layout Unit Model & Serial Number... 7 Unit Section Locations... 8 Control Component Locations... 9 Unit Model Number Code Index... 0 Unit Model Number- Complete... - 7 Electrical Legend... 8- Section A- Outdoor Air/Return Air/Economizer Section Notes... 3. 00% Outside Air Damper with Hood & No Return Air Plenum... 4 00% Outside Air Damper... 5 0-00% Economizer Section with Barometric Exhaust Damper & Return Air Fan... 6 0-00% Economizer Section with Prop Exhaust Fan & Damper... 7 0-00% Economizer Damper w/ Actuator ACT3... 8, 9 California Title 4 Assembly: Code 33= *F***... 30 Return Air Plenum Isolation Damper w/ Actuator ACT6... 3, 3 Prop Exhaust Fan & Damper... 33 Prop Exhaust Fan Inverters... 34 Prop Exhaust Fan Control Box... 35, 36 Design Flow... 37 Return Air Fan...38 Return Air Fan Fan Mounts: Code = 44B* (Until /04)... 39 Return Air Fan Fan Mounts: Code = 44B* (/04 & Later)... 40 Return Air Fan Motors... 4, 4 Section Mounted Controls- OAE, OAT, RAE, RAT, SD, LT, S, REC... 43 Section B- Draw-Thru Filter Section Notes... 44 Section Mounted Controls- PC5, LT3, S3, & REC3, Magnehelic/Differential Pressure Gauges... 44 Filters... 45, 46 Section C- Blank/Inverter (AFD/VFD) Section Notes... 47. Section Mounted Controls- LT9, S9, & REC9... 47 Section D- Draw-Thru Cooling Section Notes... 48 Evaporator Coils & Drain Pans Small Face DX Evaporator Coils: Code 03= S... 49. Large Face DX Evaporator Coils: Code 03= L... 50 Section E- Draw-Thru Spacer Section Notes... 5 Section E- Draw-Thru Heat Section for RDE Units Notes... 5 Section Mounted Controls- LT8, REC8, S8... 5 Hot Water & Steam Heat Coils, Mixing Valves, & Actuator VM... 5 Section F- Supply Air Section Notes... 53 Air Foil Fan, Double Width: Code 3= 33A*, 36A*, 40A*... 54 Air Foil Fan, Single Width: Code 3= 44B*, 49B*... 55 Fan Mounts- 33 Airfoil Double Width Fan: Code 3= 33A, 33A, 33A3... 56 Fan Mounts- 36 Airfoil Double Width Fan: Code 3= 36A, 36A, 36A3 (Until /04)... 57 Fan Mounts- 36 Airfoil Double Width Fan: Code 3= 36A, 36A, 36A3 (/04 & Later)... 58 Fan Mounts- 40 Airfoil Double Width Fan: Code 3= 40A, 40A, 40A3... 59 Fan Mounts- 44 Airfoil Single Width Fan: Code 3= 44B, 44B, 44B3... 60 Fan Mounts- 49 Airfoil Single Width Fan: Code 3= 49B, 49B, 49B3... 6 Supply Air Fan Motors... 6, 63 Belt Guards... 64 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Contents, Continued Section F- Supply Air Section, Continued Inverter Bypass Control Box (/06 & Earlier) Motor HP 5... 65, 66 Motor HP 7.5-5... 67, 68 Motor HP 30-75... 69, 70 Inverter Bypass Control Box (/07 thru 5/3) Motor HP 5... 7 Motor HP 7.5-5... 7, 73 Motor HP 30-75... 74, 75 Inverter Bypass Control Box (6/3 & Later) Motor HP 5... 76 Motor HP 7.5-5... 77, 78 Motor HP 30-75... 79, 80 Inverters... 8-85 Line Reactors... 86 Section Mounted Controls PC7, HL, LT0, S0, REC0, UV Lights... 87 MAT, EFT, SAT, DAT, OAT, SD... 88 SCB- Split Junction Box (TB5, TB7, TB8, PB0, PB9, PB0, PB9): Code 05= F... 89 Section G- Blow-Thru Heat Section for RPE Units Notes... 90 Section Mounted Controls- LT, S, REC... 90 Option - Blank Compartment: Code 04= Y Diffuser... 9 Option - Hot Water or Steam Coil Heat: Code 04= W, S Hot Water & Steam Heat Coils, Mixing Valves and Actuator (VM)... 9 Option 3- Electric Heat: Code 04= E Heaters, Hi Limit Cutouts, Diffusers... 93, 94 Electric Heat Control Box (5/3 & Earlier) Disconnect Switch DS3... 95 0-0KW Components... 96, 97 60-30KW Components... 98, 99 Electric Heat Control Box (6/3 & Later) Disconnect Switch DS3... 00 0-0KW Components...0, 0 60-30KW Components... 03, 04 Option 4- Gas Heat: Code 04= A Heat Exchangers & Vestibules: 500, 640, 650, 790, 800, 000, 00, 400MBH... 05 Heat Exchangers & Vestibules: 500, 000MBH... 06 Modulating Burner: Code 34= ****E*, ****R*, ****S*... 07-0 Hi Turn Down Burner: Code 34= ****H*, ****T*, ****U*... - 4 Modulating Burner Controls MicroTech II: Code = *D, *S... 5, 6 MicroTech III: Code = *E, *F, *W... 7 Hi Turn Down Burner Controls MicroTech II: Code = *D, *S... 8, 9 MicroTech III: Code = *E, *F, *W... 0 Gas Train Inlet- Modulating Burner... Gas Train Inlet- Hi Turn Down Burner... Modulating Burner Gas Train Controls GV, GV3... 3 Hi Turn Down Burner Gas Train Controls GV, GV4, GV5, GV6, GV7, GV8... 4 Gas Train- Outlet... 5 Gas Train- Modulating Burners w/ Actuator VM... 6 Cabinet Doors, Gasketing, Hardware, and Flue Box Mounting... 7, 8 Section H- Blow-Thru Heat Blank Access Section Notes... 9 Access Door Latching Assemblies (All Sections)... 9. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Contents, Continued Section I- Blow-Thru Cooling Section Notes... 30 Section Mounted Controls- LT6, S6, REC6... 30 Section J- Final Filter Section Notes... 3 Section Mounted Controls- HL3, PC6... 3 Filters... 3 Section K- Discharge Plenum Section for RPE Units Notes... 33 Section Mounted Controls- DAT, OAT, SD, LT5, S5, REC5... 34 Isolation Damper w/ Actuator ACT5... 35, 36 Section L- Vestibule/Access Section Notes... 37 Section Mounted Controls- LT0, S0, REC0... 37 Vestibule/Access Section Door Hardware & Wall Fan... 38 Sump Pump, Vestibule Damper, & Vestibule Heater: Code 43= B*, V*... 39 Water Treatment Controls without Water Make-Up... 40 Water Treatment Controls with Water Make-Up... 4 Section M- Condenser Section Notes... 4 Sump Water Temp. Sensor SWT, Water Level Switches WL63, WL64, & Sump Heater HTR65... 43 Fan Deck Assembly... 44, 45 Condenser Coils... 46 Compressors... 47, 48 Compressor Components... 49 Compressor Mounting... 50 Section N- Controls Notes... 5 MicroTech II: Code = *D, *S (3/05 & Earlier) Unit Control Layout Diagram... 5 Main Control Box... 53-55 Power Panel... 56-60. Control/Switch Panel... 6 Condenser Control Box... 6, 63 Compressor Control Box... 64, 65 MicroTech II: Code = *D, *S (4/05 thru /06) Main Control Box Diagram... 66 Common Components... 67-7 Supply Fan CB0, and Return Fan CB0 Circuit Breaker... 73, 74 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor... 75-80 Compressor MMP- 4 and Contactor M- 4... 8-84 Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB... 85 MicroTech II: Code = *D, *S (/07 thru /0) Main Control Box Diagram... 86 Control Box Component Label Diagram... 87 Main Control Box Common Components... 88-95. Supply Fan CB0, and Return Fan CB0 Circuit Breaker & Plugs... 96 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor... 97-0 Compressor MMP- 4 and Contactor M- 4... 03-05 Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB... 06 MicroTech III: Code = *E, *F, *W (/ thru 5/3) Main Control Box Diagram... 07 Control Box Component Label Diagram... 08 Main Control Box Common Components... 09-5. Supply Fan CB0, and Return Fan CB0 Circuit Breaker... 6 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor... 7- Compressor MMP- 4 Motor Protector & Contactor M- 4... 3-5 Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB... 6 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Contents, Continued MicroTech III: Code = *E, *F, *W (6/3 & Later) Main Control Box Diagram... 7 Control Box Component Label Diagram... 8 Main Control Box Common Components... 9-34. Supply & Return Fan Contactors, Circuit Breakers, & Fusing... 35-4 Compressor MMP- 4 Motor Protector & Contactor M- 4... 43-46 Condenser Fan Motor Protectors, Contactors, Circuit Breakers, & Fusing Components... 47, 48 Speedtrol Inverters... 49 Factory Supplied Line Voltage Box- T6, DS6, FU6A, FU6B, FU6C... 50 Oil Pressure Box... 5 Section O- Refrigeration Tubing Notes... 5. Refrigeration Circuit Diagram... 5 Refrigeration Tubing Layout Diagrams... 53, 54 Refrigeration Tubing Components... 55 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Parts List Revision History Rev. Date Description A- J 07/6 Archived Revs. A- J. K 07/6 Page : Rewrote footnote #. Page - 7: Misc. Coding updates. Page 3, 46 (OLD, 47 (NEW): Rewrote Notes. Page 40 (OLD) 37 (NEW): Moved pg. Updated the TOC. Updated dwg. Added Ref # 6 Adj. Bolt p/n to table. Page 4: Updated mtr. table. Rewrote pg. header. Page 4 (NEW): Added pg. for Shaft Grounded mtrs. Repaginated the form & updated the TOC. Page 43 (OLD) 44 (NEW): Updated Pressure Gauge dwg. & table. Page 44, 45 (OLD) 45, 46 (NEW): Updated Filter p/ns & dwg. Page 53 (OLD) 54 (NEW): Updated dwg. Page 54 (OLD) 55 (NEW): Updated dwg., bubs, & added p/ns. Page 6 (OLD) 6 (NEW): Updated mtr. table. Rewrote pg. header. Page 63 (NEW): Added pg. for Shaft Grounded mtrs. Repaginated the form & updated the TOC. Page 85 (OLD) 87 (NEW): Changed Lamp to Bulb or Fixture. Page 07, 08, (OLD) 09, 0, 3 (NEW): Misc. p/n updates. Added footnotes. Page 4, 7 (OLD) 6, 9 (NEW): Added TB Jumper p/n. Page 5, 8 (OLD) 7, 0 (NEW):Updated TBp/ns. Page 9, 0, 5 (OLD),, 7 (NEW): Updated misc. gas vlv. p/ns. Page 07, 7 (OLD) 09, 9 (NEW): Updated SPS, p/ns. Page 8 (OLD) 30 (NEW): Changed Tennant to Tenant. Page 9 (OLD) 3 (NEW): Updated T p/ns. Page 30 (OLD) 3 (NEW): Changed insure to ensure. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN 55440 (763) 553-5330 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

Nomenclature & Unit Layout Unit Model & Serial Number Unit Model Number R PE 076 C S A R = RoofPak Unit Configuration PE = Packaged Evaporative Condensing; Single Zone Unit DE = Packaged Drawthru Evaporative Condensing; Single Zone Unit Nominal Capacity (Tons) 076, 089, 00, 0, 30, 40, 50 Design Vintage Cooling Coil Size S = Small Face Area Coil L = Large Face Area Coil Heat Medium A = Natural Gas E = Electric S = Steam W = Hot Water Y = None (Cooling Only) Unit Serial Number FBO U 05 05 04800 Plant Identification FBO = Faribault, MN U= Unit Year of Manufacture 04 = 004 05 = 005 06 = 006 07 = 007 08 = 008 09 = 009 0 = 00 = 0 = 0 etc. Serial Number (build sequence) Month of Manufacture 0 = January 0 = February 03 = March 04 = April 05 = May 06 = June 07 = July 08 = August 09 = September 0 = October = November = December RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Nomenclature & Unit Layout Unit Section Locations Typical Section Locations for BlowThru RPE Units B F G I K L M A Typical Section Locations for RDE Units B D E F L M A The Unit Section Layout Diagrams shown above are to be used for reference only. Sections and Component locations vary depending on unit size, age, configuration, and options selected. Refer to the Unit Model Number Complete Section one page after next for section code information. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8

Nomenclature & Unit Layout Control Component Locations Typical Control Component Locations for RPE Units Condensor Section Discharge Plenum Section Service Section Exhaust Fan Water Treatment (Optional) Heat Section ReturnAir Economizer Water Level Switches (WL63, WL64) Sump Heater (Optional) Sump WaterTempSensor ACT5 (optional) Oil Pressure Box Water Pump Control Box VM (Optional) SD (Optional) Space Heater (Optional) HL (Optional) LT0 (Optional) S0, REC0 (Optional) ACT6 (optional) OAE S OAT LT REC (Optional) RAE (optional) Typical Control Component Locations for RDE Units Condensor Section Heat Section Supply Fan Discharge Plenum Section SV, Service Section Exhaust Fan Water Treatment (Optional) Economizer Return Air Filter Section Water Level Switches (WL63, WL64) Sump Heater (Optional) Sump Water Temp Sensor Oil Pressure Box Water Pump Control Box C9,0 (Optional) LT0 (Optional) S0, REC0 (Optional) SD (Optional) Space Heater (Optional) OAE OAT FS (Optional) LT (Optional) S, REC SD (Optional) The Control Component Layout Diagrams shown above are to be used for reference only. Sections and Component locations vary depending on unit size, age, configuration, and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 9

Nomenclature & Unit Layout Unit Model Number Code Index General Unit Options Primary Unit Model Codes that Pertain: 05, 06, 07, 50-54 (Mid 0 & Earlier), 60-66 (Mid 0 & Later) Miscellaneous Controls/Sensors Primary Unit Model Codes that Pertain: 3, 6, 7, 8 Section A= Return/Outside Air/Economizer Section Primary Unit Model Codes that Pertain: 9, 0,,, 3 (Mid 0 & Earlier), 4, 59 (Mid 0 & Later) Section B= Draw-Thru Filter Section Primary Unit Model Codes that Pertain: 5, 33 (Mid 0 & Later) Section C= Blank/Inverter (AFD/VFD) Section Primary Unit Model Codes that Pertain: 4, 5, 6 Section D= Draw-Thru Cooling Section Primary Unit Model Codes that Pertain: 03, 7, 8, 36 Section E= Draw-Thru Spacer/Blank Section Primary Unit Model Codes that Pertain: 6, 30 Section E= Draw-Thru Heat Section for RDE Units Primary Unit Model Codes that Pertain: 04, 30 Section F= Supply Air Section Primary Unit Model Codes that Pertain: 3, 3, 33 (Mid 0 & Earlier), 59 (Mid 0 & Later) Section G= Blow-Thru Heat Section for RPE Units Primary Unit Model Codes that Pertain: 04, 34 Section H= Blow-Thru Heat Blank Access Section Primary Unit Model Codes that Pertain: 34, 38 Section I= Blow-Thru Cooling Coil Section Primary Unit Model Codes that Pertain: 03, 35, 36 Section J= Final Filter Section Primary Unit Model Codes that Pertain: 39 Section K= Discharge Plenum Section Primary Unit Model Codes that Pertain: 08, 40 Section L= Vestibule/Access Section Primary Unit Model Codes that Pertain: 08, 4, 43 Section M= Condenser Section Primary Unit Model Codes that Pertain: 4, 43, 44, 45, 47 Section N= Main Control Panel Primary Unit Model Codes that Pertain: 08, 09,,, 3, 4, 5, 7, 8 Section O= Refrigeration Tubing Primary Unit Model Codes that Pertain: 45, 46 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 0

Nomenclature & Unit Layout Unit Model Number- Complete RPE 076C S A Y EU V 7 AL P LD Y 5 A CH R0 BB FE 44B JEY 50A Y AB S CYYS 4Z083D Code 03 04 05 06 07 08 09 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 YYYYYY BBBBBB 33A SEY 0890A 00SHC CYYY 4Z083D YYYYYY B B BB 6 EE H A Y Y 9 30 3 3 33 34 35 36 37 38 39 40 4 4 43 44 45 46 47 48 49 YY A A A 50 5 5 53 54 Code 03= Cooling Coil Size S= Small Face Area (076C thru 0C) L= Large Face Area (089C thru 50C) Code 04= Type of Heat Y= None A= Natural Gas Heat E= Electric Heat S= Steam Heat W= Hot Water Heat X= Special Code 05= Split Unit Y= None F= Split at Fan/Heat Section X= Special Code 06= Insulation and Liners =, 3/4# with liners on Doors = ½,.5# with solid liners on Doors & Ceilings 3= ½,.5# with perforated liners in Plenums, solid elsewhere 4= ½,.5# with solid liners on Doors, Ceilings and Floors 5= ½,.5# with perforated liners in Plenums, solid elsewhere (including Floors) 6= ½,.5# With StStl Solid Liners on Doors, Ceiling and Floors X= Special Code 07= Approval Agency Listing Digit : Unit Approval Y= None C= ETL- Canada E= ETL/MEA- USA X= Special Digit : Burner Approval Y= None (Code 04 CANNOT = A) C= ETL- Canada w/ Low Altitude Burner D= ETL- Canada w/ High Altitude Burner M, U= ETL X= Special Code 08= Main Control Box Location P= Standard Location (RPE only) S= Standard Location (RDE only) V= Vestibule X= Special Code 09= Unit Voltage = 08/60/3 9= 30/60/3 7= 460/60/3 37= 575/60/3 Code 0= Starting Option AL= Across-the-Line PW= Part Winding Start Compressors only XX= Special Code = Field Power Connection Digit : Type of Control A= One Disconnect: Complete Unit C= Two Disconnects: SAF, RAF, & Controls/Balance of Unit B= Two Disconnects: EH/Balance of Unit D= Three Disconnects: EH, SAF, RAF & CB/Balance of Unit P= One Power Block: Complete Unit Q= Two Power Blocks: EH/Balance of Unit R= Two Power Blocks - Fans & Controls/Balance of Unit X= Special Digit : Disconnect Mechanism Location = Internal (Code, Digit = P, Q, R) = Thru-the-door Disconnect (Code, Digit CANNOT= P, Q, R) X= Special Code = Temperature Controls Package MicroTech II Digit : Communication Type L= LonMark B= BACNet w/ MSTP E= BACNet w/ Ethernet S= Standalone (No Communication) X= Special Digit : Control Type D= Discharge Air Temp. Control S= Space or Zone Control X= Special MicroTech III Digit : Communication Type L= LonMark B= BACNet w/ MSTP E= BACNet w/ Ethernet S= Standalone (No Communication) C= BACNet w/ MSTP, VAV Contactor Configurable A= Daikin D3 VRV Gateway X= Special Digit : Control Type E= Discharge Air Temp. Control F= Space or Zone Control W= Discharge Air w/ Space Control XX= Special An "X" located in any position in a code string indicates a special feature. Contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). In mid 0 the code structure was changed from a 54 Code Index to a longer more detailed format. A sample 54 Code version is shown above. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code 3= Air Flow Controls Y= None = Duct Sensor = Duct Sensors 3= Duct & Space Sensor 4= Space Sensor X= Special Code 4= Inverters Y= None X= Special Separate Section = SA Fan only w/ Bypass = SA & RA Fans w/ Bypass 4= RA Fan only w/ Bypass No Separate Section 3= SA Fan only w/ Bypass 5= SA & RA Fans w/ Bypass 6= SA Fan only w/o Bypass 7= SA & RA Fans w/o Bypass 8= RA Fan only w/ Bypass 9= RA Fan only w/o Bypass Code 5= Inverter Vendor Y= None A= ABB G= Graham/Danfoss R= Reliance/Rockwell Q= Schneider S, B= Daikin Applied F= Field Installed Inverter controlled by MicroTech X= Special Code 6= Smoke Detectors Y= None = Return Air Smoke Detector = Supply Air Smoke Detector 3= Supply and Return Air Smoke Detectors X= Special Code 7= Miscellaneous Auxiliary Controls Digit : Type of Control Y= None (may include mechanical enthalpy) C= Differential Enthalpy X= Special Digit : Type of Control Y= None F= Freezestat (Steam, HW Heat) P= Phase Failure G= Ground Fault Protection L= Line Reactors w/ Inverter A= Freezestat & Phase Failure (Steam, HW Heat) B= Freezestat & Ground Fault (Steam, HW Heat) C= Phase Failure & Ground Fault D= Freezestat, Phase Failure & Ground Fault (Steam, HW Heat) E= Freezestat & Line Reactors (Steam, HW Heat w/ Inverter) H= Phase Failure & Line Reactors (w/ Inverter) J= Freezestat, Phase Failure, & Line Reactors (Steam, HW Heat w/ Inverter) K= Ground Fault, Phase Failure, & Line Reactors (Steam, HW Heat w/ Inverter) Code 7= Miscellaneous Auxiliary Controls Digit, Cont. = UV Lights = UV Lights & Freezestat (Steam, HW Heat) 3= UV Lights & Phase Failure 4= UV Lights & Line Reactors w/ Inverter 5= UV Lights, Freezestat, & Phase Failure (Steam, HW Heat) 6= UV Lights, Freezestat, & Line Reactors (Steam, HW Heat w/ Inverter) 7= UV Lights, Phase Failure & Line Reactors w/ Inverter 8= UV Lights, Freezestat, Phase Failure, & Line Reactors (Steam, HW Heat w/ Inverter) X= Special Code 8= Miscellaneous Controls/Unit Length (three digits) Y, A, S(***)= None ((***)= Air Handler Length [inches]) R, K(***)= Remote Keypad ((***)= Air Handler Length [inches]) M, P(***)= Phone Modem ((***)= Air Handler Length [inches]) W(***)= Wireless Modem ((***)= Air Handler Length [inches]) U(***)= Unit Pwr. Receptacle ((***)= Air Handler Length [inches]) V(***)= K plus Unit Pwr. Receptacle ((***)= Air Handler Length [inches]) Code 9= Return Air Plenum YY= None (No Return Air Section) BY= Bottom Return HY= Back Return LY, SY= Side (opp. drive) Return TY= Top Return BB= Bottom Return w/ Burglar Bars BE= Bottom Return w/ Isolation Damper & Actuator XX= Special Code 0= Outdoor Air Options AE= 00% Outside Air Damper w/ Hood & Actuator BE= 0-30% Outdoor Air w/ Actuator DE= 0-00% Economizer w/ Barometric Exhaust Damper w/ Actuator EE= 0-00% Economizer w/ Powered Closure Exhaust Damper w/ Actuator HE= 0-00% Economizer w/ Prop Exhaust Damper w/ Actuator FE= same as DE plus Design Flow GE= same as EE plus Design Flow JE= same as HE plus Design Flow XX= Special Code = Return Air Fan YYYY= None Digit - 3: Wheel Type 44B= 44 Airfoil (AFSW) Digit 4: Isolator type = Rubber-in-Shear (RIS) = Spring 3= Spring w/ Seismic Restraints RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code = Return Air Fan Motor YYY= None XXX= Special Digit : Motor Size H= 3.0 HP N= 0.0 HP R= 40.0 HP J= 5.0 HP M= 5.0 HP S= 50.0 HP K= 7.5 HP P= 5.0 HP T= 60.0 HP L= 0.0 HP Q= 30.0 HP (Prop Exhaust option is always J [5.0 HP]) Digit : Motor Type E= High Efficiency ODP F= High Efficiency VAV H= High Efficiency Totally-Enclosed J= Premium Efficiency ODP K= Premium Efficiency Totally-Enclosed Digit 3: Motor Options Y= None S= With With Shaft Grounding Kit Code 3= Return Air Fan Drive Selection (Mid 0 & Earlier) YYYYY= No Return Air Fan XXXXX= Special A Required RPM Service Factor/ Drive Type Service Factor/Pitch Type A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 3= Miscellaneous Electrical Options (Mid 0 & Later) Digit : UV Lights Y= None U= UV Lights X= Special Digit : Plenum Lights Y= None P= Plenum Lights X= Special Digit 3: Energy Recovery Inverter Y= None A= ABB ACH550 B= Daikin Applied Q= Schneider X= Special Digit 4: Not an RPE/RDE Code Item Y= None F= Unit powered Receptacle X= Special Digit 5: Intelligent Equipment Y= None A= IE Control X= Special Code 4= Exhaust Fans Y= None = Exhaust Fans w/ Hood 3= 3 Exhaust Fans w/ Hood X= Special Code 5= Draw-Thru Filter/Air Blender Section Digit : Section Type Y= None A= Angular 4 Section G= 4 Angular 4 Section D= Angular w/ LO CFM Blender 48/4 Section (Mid 0 & Earlier) D= Blank 4 Inch Section (Mid 0 & Later) E= Angular w/ HI CFM Blender 48/4 Section (Mid 0 & Earlier) E= Blank 48 Inch Section (Mid 0 & Later) F= Flat 4 Section H= Flat w/ HI CFM Blender 48/4 Section L= Large Staggered 48/4 Section S= Staggered 48 Section V= Staggered w/ HI CFM Blender 48/48 Section B= Blank 4 Section C= Blank 48 Section X= Special Digit : Filter Type Y= No Filters factory provided B= 30% Efficient, Throwaway C= 30% Efficient, Throwaway w/ Intersept H= 85% Efficient, Throwaway D= 65% Efficient Cartridge w/ Prefilters E= 95% Efficient Cartridge w/ Prefilters G= 95% Efficient Cartridge w/ Intersept & Prefilters X= Special Code 6= Blank Draw-thru Section Y= None E= Blank 4 Section F, S= Blank 48 Section X= Special Code 7= Draw-Thru Unit Coil Section YYYY= None CYYY= Cooling Coil Section w/ galvanized steel sloped Drain Pan CYYS= Cooling Coil Section w/ stainless steel sloped Drain Pan XXXX= Special Code 8= Draw-Thru Cooling Coil YYYYYY= No Cooling Coil 4Z 08 3 D H= Hi-F Aluminum Fin (5Z**** only) C= Hi-F Copper Fin J= Hi-F Aluminum Fin D= Lanced Aluminum 4Z= Type 4EZ 5Z= Type 5EZ XXXXXX= Special 3= 3 Row 5= 5 Row 4= 4 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch = Fins-per-inch Code 9= Not an RPE/RDE Code Item YYYYYY= None RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code 30= Draw-Thru Spacer Section YYYYYY= No Heating Section EEEEEE= Blank 4 Section BBBBBB, FFFFFF= Blank 48 Section XXXXXX= Special Code 30= Blow-Thru Heating Section (RDE only) Hydronic Heat W J 3 E E= ¼ Valve Pkg. F= ½ Valve Pkg. G=.0 Valve Pkg. H= ½ Valve Pkg. J= 3.0 Valve Pkg. = Way Steam Valve 3= 3 Way HW Valve S= 5JA060H (6FPI, Row Steam Coil) S= 5JA0H (FPI, Row Steam Coil) S3= 5JA060C (6FPI, Row Steam Coil) S4= 5JA0C (FPI, Row Steam Coil) W= 5WH090H (9FPI, Row HW Coil) W= 5WS090C (9FPI, Row HW Coil) XXXXXX= Special Code 30= Draw-Thru Heating Section (RDE only) Electric Heat E0 4 Y 4= 4 Stages 6= 6 Stages E= Electric Actuator Y= None E00= 0 KW Heater E60= 60 KW Heater E040= 40 KW Heater E00= 00 KW Heater E060= 60 KW Heater E40= 40 KW Heater E080= 80 KW Heater E80= 80 KW Heater E00= 00 KW Heater E30= 30 KW Heater E0= 0 KW Heater XXXXXX= Special Code 3= Supply Air Fan XXXX= Special Digit - 3: Wheel Type 33A= 33 Airfoil Double Width (RPE only) 33F= 33 Forward Curved, LP (RPE only) 33M= 33 Forward Curved, MP (RPE only) 36A= 36 Airfoil Double Width (RPE only) 36F= 36 Forward Curved, LP (RPE only) 36M= 36 Forward Curved, MP (RPE only) 40A= 40 Airfoil Double Width (RPE only) 40F= 40 Forward Curved, LP (RPE only) 40M= 40 Forward Curved, MP (RPE only) 44B= 44 Airfoil Single Width (RDE only) 49B= 49 Airfoil Single Width (RDE only) Digit 4: Isolator type = Rubber-in-Shear (RIS) = Spring 3= Spring w/ Seismic Restraints Code 3= Supply Air Fan Motor XXX= Special Digit : Motor Size J= 5.0 HP Q= 30.0 HP K= 7.5 HP R= 40.0 HP L= 0.0 HP S= 50.0 HP M= 5.0 HP T= 60.0 HP N= 0.0 HP U= 75.0 HP P= 5.0 HP Digit : Motor Type E= High Efficiency ODP F= High Efficiency VAV H= High Efficiency Totally-Enclosed J= Premium Efficiency ODP K= Premium Efficiency Totally-Enclosed Digit 3: Motor Options Y= None S= With With Shaft Grounding Kit Code 33= Supply Air Fan Drive Selection (Mid 0 & Earlier) XXXXX= Special A Required RPM Service Factor/ Drive Type Service Factor/Pitch Type A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 33= Miscellaneous Options (Mid 0 & Later) Digit : Gauges Y= None A= Magnehelic/Differential Filter Gauge in Draw-Thru section B= Magnehelic/Differential Filter Gauge in Blow-Thru section C= Magnehelic/Differential Filter Gauge in Draw-Thru & Blow-Thru sections Digit : California Title 4 Y= None F= Economizer with FDD Digit 3: Ebtron Air Flow Measuring Y= None S= Ebtron Air Flow (Hybrid) G= Ebtron Air Flow (Gold) Digit 4: Heating Coil Options Y= None E= Electrofin Coating Digit 5: Not an RPE/RDE Code Item Y= None Code 34= Blow-Thru Spacer Section YYYYYY= No section, cooling only BBBBBB= Blank 48 section, no heat, cooling only (RPE only) RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code 34= Blow-Thru Gas Heat Section (RPE only) 00 S H C A= Low CFM Baffle Position B= Medium CFM Baffle Position C= High CFM Baffle Position D= Extra High CFM Baffle Position Y= None E= Modulating 3: Burner, Maximum gas pressure= 0.5 psi R= Modulating Burner w/ H.P. Regulator Range= - 3 psi S= Modulating Burner w/ H.P. Regulator Range= 5-0 psi H= Hi Turn Down Burner 0: T= Hi Turn Down Burner 0: w/ H.P. Regulator Range= - 3 psi U= Hi Turn Down Burner 0: w/ H.P. Regulator Range= 5-0 psi A= Stainless Steel Primary, Aluminized Steel Secondary Heat Exchanger S= Stainless Steel Heat Exchanger 050= 500 MBH 00= 000 MBH 064= 640 MBH 0= 00 MBH 065= 650 MBH 40= 400 MBH 079= 790 MBH 50= 500 MBH 080= 800 MBH 00= 000 MBH XXXXXX= Special Code 34= Blow-Thru Steam/Hot Water Heat Section (RPE only) W J 3 E = Way Steam Valve 3= 3 Way HW Valve Y= No Valve E= ¼ Valve Pkg. F= ½ Valve Pkg. G=.0 Valve Pkg. H= ½ Valve Pkg. J= 3.0 Valve Pkg. E= Electric Actuator S= 5JA060H (6FPI, Row 5JA Steam Coil) S= 5JA0H (FPI, Row 5JA Steam Coil) S3= 5JA060C (6FPI, Row 5JA Steam Coil) S4= 5JA0C (FPI, Row 5JA Steam Coil) W= 5WH090H (9FPI, Row 5WH HW Coil) W= 5WS090C (9FPI, Row 5 WS HW Coil) XXXXXX= Special Code 34= Blow-Thru Electric Heat Section (RPE only) E00 Y None = Stage 4= 4 Stages = Stages 6= 6 Stages E00= 0 KW Heater E60= 60 KW Heater E040= 40 KW Heater E00= 00 KW Heater E060= 60 KW Heater E40= 40 KW Heater E080= 80 KW Heater E80= 80 KW Heater E00= 00 KW Heater E30= 30 KW Heater E0= 0 KW Heater Code 35= Blow-Thru Unit Coil Section YYYY= None CYYY= Cooling Coil Section w/ galvanized steel sloped Drain Pan CYYS= Cooling Coil Section w/ stainless steel sloped Drain Pan XXXX= Special Code 36= Cooling Coil (RPE only) YYYYYY= No Cooling Coil 4Z 08 3 D 4Z= Type 4EZ 5Z= Type 5EZ XXXXXX= Special 3= 3 Row 5= 5 Row 4= 4 Row 6= 6 Row 08= 8 Fins-per-inch 0= 0 Fins-per-inch = Fins-per-inch Code 37= Not an RPE/RDE Code Item YYYYYY= None H= Aluminum Fin D= Lanced Aluminum C= Copper Fin Code 38= Blow-Thru Blank/Attenuator Section Y= No section G= With 36 Std. Straight Attenuator K= With 36 Std. Straight Attenuator w/ Tedlar Coating H= With 60 Std. Straight Attenuator L= With 60 Std. Straight Attenuator w/ Tedlar Coating J= Std. Elbow Attenuator M= Std. Elbow Attenuator w/ Tedlar Coating B, F= Blank 48 Section E= Blank 4 Section RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code 39= Final Filter Section (RPE only) Y= No section A= Flat filter section, 95% cartridge, 4/4 section J= Flat filter section, 95% cartridge, 4 section B= Staggered filter section, 95% cartridge, 4/48 section K= Staggered filter section, 95% cartridge, 48 section E= Flat filter section, 95% cartridge w/ Intersept, 4/4 section L= Flat filter section, 95% cartridge w/ Intersept, 4 section W= Large Staggered section, 95% cartridge 48/4 section G= Flat filter section, 95% HEPA cartridge, 4/48 section N= Flat filter section, 95% HEPA cartridge, 48 section H= Flat filter section, 95% cartridge, 48/48 section C, Q= Blank 4/4 section D, R= Blank 4/48 section S= Blank 4 section T= Blank 48 section X= Special Code 40= Discharge Air Plenum Digit : Discharge Air Location B, G= Bottom Discharge H, L, S= LH Side (opposite Drive side) R= RH Side (Drive side) T= Top Discharge X= Special Digit : Options Y= None B= Burglar Bars (Code 40, Digit = B) E= Bottom Discharge w/ Isolation Damper & Actuator (Code 40, Digit = B) X= Special Code 4= Vestibule Compartment = 4/48 Section, out of airstream with Light X= Special Code 4= Compressor Capacity Control 4= 4 steps 6= 6 steps 8= 8 steps X= Special Code 43= Condenser Options Digit : Section Type E= Evaporative Condenser S= Evaporative Condenser w/ Sump Heater V= Evaporative Condenser w/ Heater in Vestibule B= Evaporative Condenser options w/ Sump Heater & Heater in Vestibule X= Special Digit : Water Treatment/Compressor Conduit Type Y= Bleed Off Only- Flex Conduit D= Bleed Off Only- Liquid Tight Conduit E= Dolphin, w/o Corr. Coupon, w/o Comm- Flex Conduit F= Dolphin, w/o Corr. Coupon, w/o Comm- Liquid Conduit H= Dolphin, w/o Corr. Coupon, w/ Comm- Flex Conduit J= Dolphin, w/o Corr. Coupon, w/ Comm- Liquid Conduit K= Dolphin, w/ Corr. Coupon, w/o Comm- Flex Conduit L= Dolphin, w/ Corr. Coupon, w/o Comm- Liquid Conduit M= Dolphin, w/ Corr. Coupon, w/ Comm- Flex Conduit N= Dolphin, w/ Corr. Coupon, w/ Comm- Liquid Conduit X= Special Code 44= Compressor Type H= Semi Hermetic Discus, R K= Semi Hermetic Discus, R407C Code 45= Compressor Isolation = Resilient Rubber-In-Shear (RIS) = Spring Isolation w/ Vibration Eliminators on piping X= Special Code 46= Piping Options Y= None = Hot Gas Bypass, Circuit # = Hot Gas Bypass, Circuits & 3= Replaceable Filter Drier Core 4= Hot Gas Bypass, Circuit # & Replaceable Filter Drier Core 5= Hot Gas Bypass, Circuits #, & Replaceable Filter Drier Core X= Special Code 47= Low Ambient Operation A= Speedtrol w/ ABB VFD B, S= Speedtrol w/ Daikin Applied VFD G= Speedtrol w/ Graham/Danfoss VFD Q= Speedtrol w/ Schneider VFD R= Speedtrol w/ Reliance VFD X= Special Code 48= IBC Seismic Construction/Compressor Power Factor Capacitors Y= None P= Power Factor Capacitors I= Seismic Construction X= Special Code 49= Fan Section Options Y= None A= SA Fan Belt Guard B= SA Fan Section Light C= SA Fan Belt Guard & SA Fan Section Light D= SA & RA Fan Belt Guard E= SA & RA Fan Section Light F= SA & RA Fan Belt Guard & Fan Section Light X= Special Code 50= Miscellaneous (Mid 0 & Earlier) YY= None XX= Special Code 50= Blender Section (Mid 0 & Later) Y= None L= Low CFM Blender H= High CFM Blender E= Blank 4 section F= Blank 48 section X= Special Code 5= Packaging (Mid 0 & Earlier) = Steel Skid = Consolidated Ship w/ Steel Skid F= Sheathed Crate D= Open Crate RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

Nomenclature & Unit Layout Unit Model Number- Complete, Continued Code 5= Draw-Thru Pre Heat Section (Mid 0 & Later) W J 3 E E= Electric Actuator Y= Less Actuator Code 58= Return Air Fan Drive Selection (Mid 0 & Later) YYYYY= No Return Air Fan XXXXX= Special A = Way Steam Valve 3= 3 Way HW Valve Y= No Valve E= ¼ Valve Pkg. F= ½ Valve Pkg. G=.0 Valve Pkg. H= ½ Valve Pkg. J= 3.0 Valve Pkg. S= 5JA060H (6FPI, Row 5JA Steam Coil) S= 5JA0H (FPI, Row 5JA Steam Coil) S3= 5JA060C (6FPI, Row 5JA Steam Coil) S4= 5JA0C (FPI, Row 5JA Steam Coil) W= 5WH090H (9FPI, Row 5WH HW Coil) W= 5WS090C (9FPI, Row 5 WS HW Coil) EEEEEE= Blank 4 section FFFFFF= Blank 48 section XXXXXX= Special Code 5= Parts Warranty (Mid 0 & Earlier) A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 5= Drain Pan/Humidifier Section (Mid 0 & Later) YY= None DY= Drain Pan only 48 section DH= Drain Pan & Humidifier 48 section Code 53= Compressor Warranty (Mid 0 & Earlier) A= Standard One Year Compressor Q= Extended Four Year Compressor, Five Year Total Z= Special Code 53= Custom Unit Specifications YY= None XX= Special Code 54= Heat Exchanger Warranty (Mid 0 & Earlier) Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special Code 54= Final Filter Section (RPE only) (Mid 0 & Earlier) Y= None A= Flat Section, 95% Cartridge Filters, 4/4 Section B= Staggered Section, 95% Cartridge Filters, 4/48 Section C= Blank 4/4 Section D= Blank 4/48 Section E= Flat Section, 95% Cartridge Filters w/ Intersept, 4/4 Section F= Staggered Section, 95% Cartridge Filters w/ Intersept, 4/48 Section X= Special Codes 54-57= Not RPE/RDE Code Items (Mid 0 & Later) YYYYYYYY= None Required RPM Service Factor/Pitch Type A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 59= Supply Air Fan Drive Selection (Mid 0 & Later) XXXXX= Special A Required RPM Service Factor/ Drive Type Service Factor/ Drive Type Service Factor/Pitch Type A= Std. SF/Fixed Pitch B= 50% SF/Fixed Pitch C= Std. SF/Variable Pitch D= 50% SF/Variable Pitch Code 60= Miscellaneous (Mid 0 & Later) YY= None XX= Special Code 6= Packaging (Mid 0 & Later) = Steel Skid = Consolidated Ship w/ Steel Skid F= Sheathed Crate D= Open Crate Code 6= Parts Warranty (Mid 0 & Later) A= Standard One Year Parts C= Extended One Year Parts, Two Year Total D= Extended Two Year Parts, Three Year Total E= Extended Three Year Parts, Four Year Total F= Extended Four Year Parts, Five Year Total Z= Special Code 63= Compressor Warranty (Mid 0 & Later) A= Standard One Year Compressor Q= Extended Four Year Compressor, Five Year Total Z= Special Code 64= Heat Exchanger Warranty (Mid 0 & Earlier) Y= None (Code 04 CANNOT= A) A= Standard One Year Heat Exchanger R= Extended Nine Year Heat Exchanger, Ten Year Total Z= Special Code 65= Factory Code (Mid 0 & Later) 077C= Unit Configurator Code 66= Drain Connection (Mid 0 & Later) R= RH (Drive side) L= LH (opposite drive side) Code 67= Not an RPE/RDE Code Item (Mid 0 & Later) Y= None Code 68= Short Circuit Current Rating (Mid 0 & Later) 0= 0 SCCR YY= None XX= Special RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Nomenclature & Unit Layout Electrical Legend Schematic Sym. Description Location ACT3, 4 Actuator Motors- Economizer Dampers Economizer Section ACT5 Actuator Motor- Discharge Isolation Damper Discharge Section ACT6 Actuator Motor- Return Air Isolation Damper Return Air Section ACT7 Actuator Motor- Heat Face/Bypass Coil Section, Heat ACT8 Actuator Motor- Cool Face/Bypass Coil Section, Cool ACT0, Actuator Motors- Exhaust Dampers Return Air Section ACT6 Actuator Motor- Sump Fill Vestibule Section ACT6 Actuator Motor- Sump Blow Down Vestibule Section ACT63 Actuator Motor- Auto System Drain Vestibule Section ACT64 Actuator Motor- Sump Purge Vestibule Section AFD0 Adjustable Frequency Drive- Supply Fan AFD/Supply Fan Sect. AFD Adjustable Frequency Drive- Condenser Fans Main/Cond. Control Box AFD0 Adjustable Frequency Drive- Return/Exhaust Fan AFD/Supply/Exhaust Sect. AS Blower Air Switch Gas Heat Section BM Burner Blower Motor Gas Heat Section C- C8 Power Factor Capacitors- Compressors Condenser Section C0 Power Factor Capacitors- Supply Fan Supply Air Section C Capacitor- SpeedTrol (Circuit #) Condenser Bulkhead C0 Power Factor Capacitors- Return Fan Return Air Section C Capacitor- SpeedTrol (Circuit #) Condenser Bulkhead CB0 Circuit Breaker- Supply Fan Main Control Box CB Circuit Breaker- Condenser Fans Main/Cond. Control Box CB0 Circuit Breaker- Return Fan Main Control Box CCB, Compressor Control Boards (MicroTech II) Main/Cond. Control Box COMPR- 4 Compressors Condenser Section CS, Control Switches- Refrigerant Circuits Main/Cond. Control Box DAT Discharge Air Temperature Sensor Discharge section DFLH Design Flow Sensor- Left Hand Return Section DFRH Design Flow Sensor- Right Hand Return Section DHL Duct High Limit Main Control Box Dolphin T Transformer, Sump Vestibule Dolphin T Transformer, Make Up Water Vestibule Dolphin CTL Conductivity Control Vestibule DS Disconnect- Total Unit or Condenser/Heat Main Control Box DS Disconnect- SAF/RAF/Controls Main Control Box DS3 Disconnect- Electric Heat Electric Heat Section DS6 Disconnect- Factory Powered Outlet Condenser Section EFT Entering Air Temperature Sensor Supply Fan Section EHB Staged Electric Heat Board (MicroTech II) Main Control Box EXPA- D Expansion Boards (MicroTech III) Main Control Box F, A Fuses- Control Circuit, T Primary Main Control Box FC Fuse- Control Circuit, T Secondary Main Control Box F Fuse- Control Circuit, T Primary Main Control Box F3 Fuse- Burner Motor Main Control Box F6A, B Fuses- T6 Transformer, Primary Condenser Section F6C Fuse- T6 Transformer, Secondary Condenser Section FB9, 0 Fuseblocks- Supply Fan Main/Cond. Control Box FB,,, 3, FS Fuseblocks- SpeedTrol Main/Cond. Control Box Component locations listed are are typical and are to be used for reference only. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8

Nomenclature & Unit Layout Electrical Legend, Continued Schematic Sym. Description Location FB9, 0 Fuseblocks- Exhaust/Return Fan Main/Cond. Control Box FB3-40 Fuseblocks- Electric Heat (Top Bank) Electric Heat Section FB4-50 Fuseblocks- Electric Heat (Bottom Bank) Electric Heat Section FB64 Fuseblock- Condenser Water Pump Main/Cond. Control Box FB65 Fuseblock- Condenser Sump Heater Main/Cond. Control Box FD Flame Detector Gas Heat Section FLC Fan Limit Control Gas Heat Section FP, Frost Protection- Refrigeration Circuits Coil Section, Cool FS, Freezestats Coil Section, Heat/Cool FSG Flame Safeguard Gas Heat Section GCB Generic Condenser Board (MicroTech II) Main Control Box GFS/GFR Ground Fault Sensor/Relay Main Control Box GFS/GFR Ground Fault Sensor/Relay Main Control Box GFS4/GFR4 Ground Fault Sensor/Relay Condenser Control Box GRD Ground All Control Boxes GV Gas Valve- Pilot Gas Heat Section GV Gas Valve- Main/Safety Gas Heat Section GV3 Gas Valve- Redundant/Safety Gas Heat Section GV4-8 Gas Valves- Main, Hi-Turn Down Gas Heat Section HL- 0 High Limits- Elec. Heaters, Power (Top Bank) Electric Heat Section HL- 0 High Limits- Elec. Heaters, Power (Bottom Bank) Electric Heat Section HL High Limit- Gas Heat (Prefilters) Supply Air Section HL3 High Limit- Gas Heat (Final Filter) Final Filter Section HL3-40 High Limits- Elec. Heaters, Control (Top Bank) Electric Heat Section HL4-50 High Limits- Elec. Heaters, Control (Bottom Bank) Electric Heat Section HP- 4 High Pressure Controls- Refrigerant On Compressors HP5 High Pressure Control- Gas Gas Heat Section HS Heat Switch- Electric Shutdown Main Control Box HS3 Heat Switch- Electric Heat Deadfront Interlock Electric Heat Section HTR- 4 Compressor Crankcase Heaters On Compressors HTR65 Heater- Sump Condenser Section HTR66 Heater- Vestibule Condenser Vestibule IT Ignition Transformer Gas Heat Section LP, Low Pressure Controls- Refrigerant On Compressors LP5 Low Pressure Control- Gas Gas Heat Section LR0 Line Reactor- Supply Fan Inverter Bypass CB LR, Line Reactors- SpeedTrol Condenser Section LR0 Line Reactor- Return/Exhaust Fan Inverter Bypass/Main CB LS, Limit Switches- Low Fire/High Fire Gas Heat Section LT0 Light- Supply Fan Supply Air Section LT Light- Return Fan Return Air Section LT Light- Heat Section Heat Section LT3 Light- Filter Section Filter Section LT4 Light- Final Filter Section Final Filter Section LT5 Light- Discharge Section Discharge Section LT6 Light- Blow-Thru Coil Section Blow-Thru Coil Section LT7 Light- Evaporator Coil Section Evaporator Coil Section LT8 Light- Preheat Section Preheat Section LT9 Light- Blank Section Blank Section Component locations listed are are typical and are to be used for reference only. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 9

Nomenclature & Unit Layout Electrical Legend, Continued Schematic Sym. Description Location LT0 Light- Blank Compartment Blank Compartment LT Light- Draw-Thru Coil Section Draw-Thru Coil Section LT Light- Condenser Section Condenser Section LT3 Light- Vestibule Condenser Vestibule M- 4 Contactors- Compressors Main/Cond. Control Box M0 Contactor- Supply Fan Main Control Box M- 8 Contactors- Condenser Fans, Circuit # Main/Cond. Control Box M0 Contactor- Return Fan Main Control Box M- 8 Contactors- Condenser Fans, Circuit # Main/Cond. Control Box M9 Contactor- Burner Motor Gas Heat Section M30 Contactor- Supply Fan Inverter Bypass Inverter Bypass Box M3-39 Contactors- Elec. Heaters (Top Bank) Electric Heat Section M40 Contactor- Return Fan Inverter Bypass Inverter Bypass Box M4-50 Contactors- Elec. Heaters (Bottom Bank) Electric Heat Section M64 Contactor- Sump Pump Main/Cond. Control Box M65 Contactor- Sump Heater Main/Cond. Control Box MCB Microprocessor Control Board Main Control Box MJ Mechanical Jumpers All Control Boxes MMP- 4 Manual Motor Protectors- Compressors Main/Cond. Control Box MMP0 Manual Motor Protector- Supply Fan Main Control Box MMP- 8 Manual Motor Protectors- Condenser Fans Ckt. Main/Cond. Control Box MMP0 Manual Motor Protector- Return Fan Main Control Box MMP- 8 Manual Motor Protectors- Condenser Fans Ckt. Main/Cond. Control Box MMP30 Manual Motor Protector- Supply Fan Inverter Bypass Inverter Bypass Box MMP40 Manual Motor Protector- Return Fan Inverter Bypass Inverter Bypass Box MMP5-53 Manual Motor Protectors- Prop Exhaust Fan Motors Return Air Section MMP64 Manual Motor Protector- Sump Pump Main/Cond. Control Box MP- 4 Motor Protectors- Compressors On Compressors OAE Outside Air Enthalpy Control Economizer Section OAT Outside Air Temperature Sensor Discharge Bulkhead OP- 4 Oil Pressure Controls- Compressors Condenser Section PB, Powerblocks- Power Distribution Main Control Box PB3 Powerblock- Electric Heat Electric Heat Section PB4 Powerblock- Condenser Condenser Control Box PB9, 0 Powerblocks- Supply Fan Unit Split Junction Box PB, Powerblocks- Power Distribution Main Control Box PB9, 0 Powerblocks- Return/Exhaust Fan Unit Split Junction Box PC5 Pressure Control- Clogged Filter Pre Filter Section PC6 Pressure Control- Clogged Final Filter Final Filter Section PC7 Pressure Control- Proof of Airflow Supply Air Filter PC8 Pressure Control- Minimum Airflow Coil Section, Cool PS- 3 Pumpdown Switches- Refrigerant Circuits Main/Cond. Control Box PT,,, Pressure Transducers- SpeedTrol Pressure/Cond. Section PVM, Phase Voltage Monitors Main Control Box PVM4 Phase Voltage Monitor- Condenser Condenser Control Box R, Relays- High Pressure Reset Main/Cond. Control Box R3, 4 Relays- Hi Pressure Delay Main/Cond. Control Box R5-8 Relays- Compressor, Safety/Cool Fail Main/Cond. Control Box R9, 0 Relays- Compressor Lockout Main/Cond. Control Box Component locations listed are are typical and are to be used for reference only. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 0

Nomenclature & Unit Layout Electrical Legend, Continued Schematic Sym. Description Location R, Relays- SpeedTrol Fan Cycling (MicroTech II) Main/Cond. Control Box R, 7 Relays- SpeedTrol Inverter Enable Main/Cond./Pressure Box R- 4 Relays- FanTrol Condenser Fan Cycling Main Control Box R0 Relay- Gas, Steam, Hot Water Heat Gas Section/Main CB R, Relays- Gas Heat, High Turndown Gas Heat Section R3 Relay- Gas/Electric Heat Gas Sect./Elec. Ht. CB R4 Relay- Gas Heat Alarm Main Control Box R5 Relay- Gas Heat Start, Supply Fan Inverter Main Control Box R6 Relay- Isol./Exh. Dampers Open/Close Main Control Box R8 Relay- Isolation Damper Safety Main Control Box R9 Relay- Remote Fire Alarm Main Control Box R30 Relay- Cool Valve w/ Face & Bypass Main Control Box R45 Relay- UV Lights Main Control Box R46, 47 Relays- Supply Fan Inverter increase/decrease Main Control Box R48, 49 Relays- Return Fan Inverter increase/decrease Main Control Box R56 Relay- Water Pipe Heater Main/Cond. Control Box R57 Relay- Sump Fill Main Control Box R6 Relay- Smoke Detector, Discharge Air Main Control Box R6, 63, 65 Relays- Specials Main Control Box R64 Relay- Sump Pump Main/Cond. Control Box R66 Relay- RA Smoke Detector Main Control Box R67 Relay- Supply Fan Enable Main Control Box R68 Relay- Return Fan Enable Main Control Box R69 Relay- Inverter Bypass VAV Box Interlock Main Control Box R70-79 Relays- Specials Main Control Box RAE Return Air Enthalpy Sensor Return Air Section RAT Return Air Temperature Sensor Return Air Section REC Receptacle- Main Box Main Control Box REC Receptacle- Condenser Box Condenser Section REC3 Receptacle- Field Power, 5V Discharge Bulkhead REC0-3 Receptacles- Cabinet Sections Cabinet Sections S Switch- System On/Off Main Control Box S3 Switch- Furnace On/Off Gas Heat Section S4 Switch- Inverter Bypass On/Off Main Control Box S7 Switch- Local On/Off/Auto to Controller Main Control Box S0-3 Switches- Cabinet Section Lights Cabinet Sections S40-45 Switches- Door Interlock, UV Lights Cabinet Sections SD Smoke Detector- Supply Air Discharge Section SD Smoke Detector- Return Air Return Air Section SHS Space Humidity Sensor Return Section/Field Inst. SPS, Static Pressure Sensors- Duct or Building Main Control Box SR- 3 Sequence Relays- Electric Heat Electric Heat Section SV, Solenoid Valves- Liquid Condenser Section SV5, 6 Solenoid Valves- Hot Gas Bypass Condenser Section SV6, 6 Solenoid Valves- Sump Fill Main/Cond. Control Box SV63 Solenoid Valve- Sump Drain Main/Cond. Control Box SWT Sensor- Sump Water Temperature Condenser Section T Transformer- Main Control, 5V Main Control Box Component locations listed are are typical and are to be used for reference only. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Nomenclature & Unit Layout Electrical Legend, Continued Schematic Sym. Description Location T Transformer- Control Input, 5/4V Main Control Box T3 Transformer- Control Output, 5/4V Main Control Box T4 Transformer- Exhaust Damper Actuator, 5/V Main Control Box T5 Transformer- Electric Heat Electric Heat Section T6 Transformer- Unit Supplied, 5V Condenser Section T9 Transformer- Refrigerant Circuit, 4V Main Control Box TB, 3 Terminal Blocks- Factory Main Control Box TB, 4 Terminal Blocks- Field Main/Cond. Control Box TB5, 6 Terminal Blocks Condenser Section TB7, 8 Terminal Blocks- 5V Convenience Outlet Main/Cond. Control Box TB Terminal Block- Heat Gas Sect./Elec. Ht. CB TB3 Terminal Block- Oil Pressure Box Condenser Vestibule TB5-8 Terminal Blocks- Split Unit Junction Box Unit Split Junction Box TC- 4 Temperature Controls- FanTrol Condenser Control Box TC56 Temperature Control- Water Pipe Heater Condenser Vestibule TC66 Temperature Control- Vestibule Exhaust Fan Condenser Vestibule TD, Time Delays- Compressor Lockout Main/Cond. Control Box TD3, 4 Time Delays- High Pressure Main/Cond. Control Box TD0 Time Delay- Hi-Turn Down Burner Gas Heat Section TD, Time Delays- Low Ambient Main/Cond. Control Box TD0 Time Delay- Return Air Fan Main Control Box TD64 Time Delay- Oil Pressure Condenser Section TR, Transducer- Pressure Main Control Box U, Unloaders- Compressors On Compressors UV Ultra Violet Lights Coil/Discharge Section VFD0 Adjustable Frequency Drive- Supply Fan Dr-Thru/Supply Fan Sect. VFD, Adjustable Frequency Drives- SpeedTrol Condenser Section VFD0 Adjustable Frequency Drive- Return/Exhaust Fan Dr-Thru/Ret/Exh Fan Sect. VM Valve Motor- Heating Heating Section VM5 Valve Motor- Cooling Coil Section, Cool VV Vent Valve Gas Heat Section WL63 Water Level- Sump Fill Condenser Section WL64 Water Level- Sump Low Water Condenser Section ZNT Zone Temperature Sensor- Control Field Installed Component locations listed are are typical and are to be used for reference only. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Section A- Outdoor Air/Return Air/Economizer Section Notes Primary Unit Model Codes that Pertain: 9, 0,,, 3 (Mid 0 & Earlier), 4, 58 (Mid 0 & Later) Additional Codes that pertain: 06, 09,, 6, 7, 49 Codes 9 and 0 determine the base section. Code 9 refers to the Return Air Plenum, and determines if the unit has bottom return air (Code 9= B*), back return air (Code 9= H*), or side return air (Code 9= S*). A Return Air Plenum is required for any outdoor air application with an Economizer (Code 0= D*, E*, F*, G*, H*, J*). The only case in which a Plenum is NOT required is when a 00% Outdoor Air Damper and Hood are ordered (Code 0= AE). Codes,, 3 (Mid 0 & Earlier), AND/OR 58 (Mid 0 & Later) determine the Return Air Fan, Motor, and Drive components. These codes only pertain to units with a 0-00% Economizer (Code 0= D*, E*, F*, G*, H*, J*). Return Air Fan section parts, Fan Wheels, and Motors are listed in this section. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it with the Drive Components Cross Reference, form number 57006, or contact Daikin Applied with model and serial number information for identification. Fan Motors range from 3-60 horsepower, and the Fan Wheel is a 44 Single Width Airfoil (AFSW). Code 4 indicates whether the unit is equipped with two or three Exhaust Fans and Exhaust Hoods. Code 06 determines the panels used in final cabinet assembly. For sheet metal components that make up the Outdoor/Return Air/Economizer Section, contact Daikin Applied with model and serial number information to ensure that the correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Code 09, unit voltage, is part of the Return Fan Motor part number identification. Code, the control system, comes into play when an Economizer is present by modulating airflow through the unit. If Code 6=, 3 a Smoke Detector (SD) is present in the Return Air Section. Code 7 determines the type of Enthalpy and Miscellaneous Auxiliary Controls included. The second digit of Code 7 lists the inclusion of Freezstats, Phase Failure, Line Reactors, and Ground Fault protection. See the Unit Code Index section to determine which options were specified. Code 49 determines if the Return Air Fan has a Fan Belt Guard and/or a Cabinet Light. If Code 49= D, the Return Air Section has a Fan Belt Guard. If Code 49= E the Return Air Section has a Cabinet Light. Code 49= F indicates both options have been selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Section A- Outdoor Air/Return Air/Economizer Section 00% Outside Air Damper with Hood & No Return Air Plenum Code 0= AE AND Code 9= YY 9 Air Flow 00 9 5 4 3 0 5 Ref. Part Part Qty. No. Description Number 00 Damper Assy. 0983380 9 Liner 056370 0 Panel- Hood Side 056303 Panel- Hood Side 056304 Panel- Hood Top 056380 3 Louver 056300 5 4 Channel- Support 0563403 5 Channel- Support 05630 This assembly includes the Damper and Linkage, but NO Actuator. For Damper & Actuator components refer to the following page. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Section A- Outdoor Air/Return Air/Economizer Section 00% Outside Air Damper Code 0= AE AND Code 9= YY (/07 & Earlier) 4 Motorized Linkage Detail 7 3 5 3 0 7 8 6 6 4 4 6 9 4 Ref. Part Part Qty. No. Description Number 4 Shaft- Linkage 05597970 6 Adapter Plate- CrankArm 0555400 3 Blade- Damper 0449503 3 4 Grille 0559860 6 Stop/Anti- Rotate- Damper 06577980 7 Support- Damper Motor 0559800 0 Crank Arm- Damper 037900 Ball Joint- Damper 000887000 4 Actuator- Motorized (ACT3) 059999804 3 Bushing- Linkage Bar, Nylon 046098300 4 Bushing- Damper Blade, Nylon 043730400 4 5 Gasket- Vinyl 044936 6 Gasket- Vinyl 04565576 7 Plug- Damper End 0400350 8 Plug- Damper End 0400350 6 9 Plug- Damper End 04003503 6 For units built /08 & Later contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Section A- Outdoor Air/Return Air/Economizer Section 0-00% Economizer Section with Barometric Exhaust Damper & Return Air Fan Code 0= DE, EE, FE, GE 60 4 6 5 4 00 Bottom Return (Code 9= B*) shown Ref. Part Part Qty. No. Description Number 00 Economizer Damper (Code 0= DE, EE, FE, GE) 60 Exhaust Damper Assy Powered (Code 0= EE, GE) 04040 Barometric (Code 0= DE, FE) 03960 4 Fan Guard 05595760 3 5 Fan Guard 0559576 6 Fan Guard 0559576 Contact Daikin Applied with model and serial number information so that the correct Damper Assembly can be identified. Economizer detail follows one page after next. Exhaust Damper detail follows five pages after next. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

Section A- Outdoor Air/Return Air/Economizer Section 0-00% Economizer Section with Prop Exhaust Fan & Damper Code 0= HE, JE AND Code 4=, 3 Fan Guard 40 30 40 4 40 3 Fan Arrangement w/ Hood Shown (Code 4= 3) Ref. Part Part Qty. No. Description Number N/S Economizer Damper w/ Actuator (Code 0= HE, JE) 4 Hood- Prop Exhaust 830 Grille- Prop Exhaust 80 30 Fan Guard 840 Grill- Fan Guard 890 40 Exhaust Fan Assembly 3 08/30/ 05660 4 Exhaust Fan Assembly 3 05660 4 N/S= Not Shown on diagram. Quantity is PER fan. Contact Daikin Applied with model and serial number information so that the correct Damper Assembly can be identified. Economizer detail follows on the next two pages. 3 Exhaust Fan detail follows four pages after next. 4 Quantity may be two (Code 4= ) OR three (Code 4= 3). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Section A- Outdoor Air/Return Air/Economizer Section 0-00% Economizer Damper w/ Actuator ACT3- Diagrams Code 0= DE, EE, FE, GE, HE, JE 4 6 3 7 5 3 8 8 6 4 9 Detail (/ & Later) Detail (/ & Earlier) 3 7 9 6 7 4 40 0 6 4 40 7 9 40 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8

Section A- Outdoor Air/Return Air/Economizer Section 0-00% Economizer Damper w/ Actuator ACT3- Components Code 0= DE, EE, FE, GE, HE, JE Ref. Part Part Qty. No. Description Number 4 Shaft Assembly 05839000 6 Plate- Crank Arm / & Earlier 0555400 Shaft Assy.- Damper Linkage / & Later 06630059 7 Shaft- Linkage 05838990 Channel- Actuator Mount / & Later 40363050 3 Blade- Damper 0449503 6 Stop/Anti-Rotate- Damper 06577980 4 7 Support- Damper Motor / & Earlier 05554660 8 Bar- Linkage 04494800 9 Drive Tab- Linkage Bar 04494900 0 Crank Arm- Damper / & Earlier 037900 Ball Joint- Damper 000887000 4 Actuator, ACT3, 0V / & Earlier 059999804 Actuator, ACT3, 4V / & Later 33950 3 Bushing- Linkage Bar 046098300 4 Bushing- Damper Blade 043730400 4 5 Gasket- Vinyl 044936 6 Gasket- Vinyl 04565576 7 End Plug- Damper 0400350 8 End Plug- Damper 0400350 6 9 End Plug- Damper 04003503 6 3 Bearing- Flange / & Later 04738504 40 Nut 040499904 4 N/S Gasket- Neoprene 05600350 4 N/S= Not Shown on Diagram. Applied from outer edge of assembly to inside edge of center support and flush with edge of the bottom channel. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 9

Section A- Outdoor Air/Return Air/Economizer Section California Title 4 Assembly Code 33 (Mid 0 & Later) = *F*** 3533 3534 3535 3536 Ref. Part Part Qty. No. Description Number 3533 Cover, Mounting Switch 4045956 3534 Bracket, Mounting Switch 4045956 3535 Switch, Push Button SPDT 033696300 3536 Bushing, Conduit 3630 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 30

Section A- Outdoor Air/Return Air/Economizer Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE Diagrams 0/ & Earlier ACT6 Actuator Detail 5 0 3 5 8 0 3 6 4 4 9 7 0/ & Later ACT6 Actuator Detail 5 0 3 5 8 0 8 3 6 4 4 7 9 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Section A- Outdoor Air/Return Air/Economizer Section Return Air Plenum Isolation Damper w/ Actuator ACT6 Code 9= BE Components Ref. Part Part Qty. No. Description Number Isolation Damper Assy- Motorized / & Earlier 05596 Isolation Damper Assy- Motorized / & Later 40376306 3 Motor Mount Assembly / & Earlier 05590 Motor Mount Assembly / & Later 0559370 4 Blade Assembly- Return, 4 055930 5 5 Angle- Linkage 0559790 3 6 Angle- Blade 0556380 45 7 Shaft- Damper Blade 05563780 30 8 Shaft- Linkage 05553660 9 Bearing, Flange, Nylon 003500 30 0 Actuator- Motorized- SPDT (ACT6), 0V / & Earlier 059999804 Actuator- Motorized- SPDT (ACT6), 4V / & Later 34490 Crank Arm- Damper / & Earlier 037900 Crank Arm- Damper / & Later 403770 Ball Joint 000887000 3 Bearing- Sleeve 04738507 45 4 Gasket, Vinyl 03005985 6 8 Bearing- Sleeve / & Later 04738504 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Section A- Outdoor Air/Return Air/Economizer Section Prop Exhaust Fan & Damper Code 0= HE, JE AND Code 4=, 3 6 54 5 B 6C A 6B 6H 6D 6E 6F 6G 6A Lube Line Detail 53 Control Box (see one page after next) 6I Voltage Ref. Sch. Part Part No. Sym. Description Number AFD0 Inverter see charts on following page A Resistor- Inverter 04469005 B Jumper- Inverter 0557973 3 3 3 3 6 Fan Assembly- Complete 08/30/ 05660 Fan Assembly- Complete 05660 6A Damper- Backdraft 3 6B Fan Prop, 36 30004407 4 4 4 4 6C Fan Shaft 30004408 4 4 4 4 6D Bearing 30004409 4 4 4 4 6E Fan Sheave 099400 4 4 4 4 6F Bushing- Fan Sheave 000804000 4 4 4 4 6G Belt 04960805 4 4 4 4 6H Motor Sheave 000607600 4 4 4 4 6I Motor 300046887 4 4 4 Motor 3000465 4 5 Tube- Plastic 00954800 5 5 5 5 53 Coupling- Tube.5 x.5 FPT 03800 4 4 4 4 54 Fitting- Grease 00009800 4 4 4 4 Quantity= when Inverter model 3500 (Code 5= G) is used. Quantity shown are for fans. Quantities for 3 fan units: Ref. 5= 3 ; Ref. 53= 6; Ref. 54= 6. 3 Contact Daikin Applied with model and serial number information so that the correct part can be identified. 4 Quantity is PER fan. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 33

Section A- Outdoor/Return Air Section Prop Exhaust Fan Inverters AFD0 Code 0= HE, HY, JE, JY AND Code 4=, 3 Inverter- Fan Units (Code 4= ) 05/3 & Earlier Voltage Code Inverter Model Part 5= Number A ACH550 04607 ACH550 046004 G 3500 09865698 3500 09865698 3500 098656905 R VTAC9 046870 VTAC9 046856 S MD 934758 MD 9347587 Inverter- 3 Fan Units (Code 4= 3) Voltage Code Inverter Model Part 5= Number A ACH550 04608 ACH550 046005 G 3500 09865699 3500 09865699 3500 098656906 R VTAC9 04687 VTAC9 046857 S MD 934758 MD 9347588 The Keypad Display for Model 550 Inverters is p/n 30004094. For Inverters, contact Daikin Applied with model and serial number information so that the correct Inverter can be identified. Inverter- Fan Units (Code 4= ) Voltage 4 Code Inverter Model Part 5= Number A ACH550 3 04607 ACH550 3 046004 B MD4 3 93557 MD4 3 935504 G 3500 09865698 3500 09865698 3500 098656905 Q MD 93555 MD 93550 R VTAC9 046870 VTAC9 046856 S, Q MD 934758 MD 9347587 06/3 & Later Inverter- 3 Fan Units (Code 4= 3) Voltage 4 Code Inverter Model Part 5= Number A ACH550 3 04608 ACH550 3 046005 B MD4 3 93558 MD4 3 935505 G 3500 09865699 3500 09865699 3500 098656906 R VTAC9 04687 VTAC9 046857 S, Q MD 3499566 MD 34995668 3 The Keypad Display for Model 550 AND MD4 Inverters is p/n 30004094. 4 For Inverters, contact Daikin Applied with model and serial number information so that the correct Inverter can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 34

MMP5 MMP5 Section A- Outdoor/Return Air Section Prop Exhaust Fan Control Box Until 3/05 0 3 35 36 Fan Unit shown Voltage Ref. Sch. Part Part No. Sym. Description Number 0 PB0 Power Block 03037705 3 M5, 5 Contactor 07540 35 OL5, 5 Overload 36 Heater- Overload 6 6 Heater- Overload 6 6 NOTE: Quantites for Contactors and Overloads shown are for a Fan unit (Code 4= ). PB0 is used on units where the Inverter is field installed (Code 5= F). Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. 3/05 thru 0/06 4 40 4 MMP5 and MMP5 Detail Voltage Ref. Sch. Part Part No. Sym. Description Number 40 MMP5, 5 MMP- Prop Exh. Motors 3499340 MMP- Prop Exh. Motors 34993400 MMP- Prop Exh. Motors 349934009 4 Line Shield 34993300 4 Short Circuit Alarm 349933903 NOTE: Quantity shown is for a Fan unit (Code 4= ). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 35

Section A- Outdoor Air/Return Air/Economizer Section Prop Exhaust Fan Control Box /06 thru 5/3 OL5 M5 OL5 M5 0 Contactors & Overloads Detail Voltage Ref. Sch. Part Part No. Sym. Description Number 0 OL5, 5 Overload 349934663 Overload 34993466 Overload 349934660 Overload 349934659 30 M5, 5 Contactor 349933 Contactor 34993 NOTE: Quantity shown is for a Fan unit (Code 4= ). Fan Units 30 06/3 & Later Prop Exhaust Fan Control Box 0 30 OL5 OL5 M5 M5 Fan Unit shown 0 30 Voltage Ref. Sch. Part Part No. Sym. Description Number 0 OL5, 5 Overload 9354800 Overload 93548009 Overload 9354790 Overload 93547909 30 M5, 5 Contactor 5A 93537304 Contactor 6A 9359006 Contactor 9A 9353406 Contactor 7A 9353405 NOTE: Quantity shown is for a Fan unit (Code 4= ). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 36

Section A- Outdoor Air/Return Air/Economizer Section Design Flow: Code 0= FE, GE, JE LH Louvered Door Assy 0 Louvered Door Assembly Detail Section Final Assembly RH Louvered Door Assy 9 09 3 05 7 04 06 04 0 0 30 Vane Panel Detail Adjuster Control Assy. Detail Spring Detail Ref. Part Part Qty. No. Description Number 9 Potentiometer 09866370 O Ring- Potentiometer 09866380 Louver Panel Left Hand Door 05959504 5 Louver Panel Right Hand Door 05959503 5 0 Grille 055930 04 Panel- Vane 09866803 05 Shaft- Upper 0986660 06 Bearing- Lower 0963450 09 Crank Arm Assy Left Hand Door 0965880 Crank Arm Assy Right Hand Door 0965880 0 Link Arm 0 Bearing 060040 7 Bearing 04738535 30 Spring- Main 09866470 3 Spring- Secondary 09866490 N/S Leveling Kit- Design Flow 0965930 N/S= Not shown on diagram. Quantity is PER door. P/N is unit specific. Contact Daikin Applied with overall length and bolt hole spacing so that the correct part can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 37

Section A- Outdoor Air/Return Air/Economizer Section Return Air Fan: Code = 44B* 7 6 35 9 7 8 3 4 37 3 63 48 6 36 6 4 5 Ref. Motor Part Part Qty. No. HP Description Number Motor see following page 4 All Mount- Motor 056340 5 All Channel Assembly 056340 6 All Adjustment Bolt Assy., Motor Base 0563390 All Clamp- Motor Channel 0563003 All Clamp- Motor Channel 0563003 3 All Shaft- Fan.438 dia. 0565503 7 All Tubing- Plastic 036745 8 All Coupling until /04 03700 All Coupling /04 & later 07674000 9 All Coupling 0767400 All Fitting- Grease /8 MPS 00009800 3 All Bearing- Ball, Flange.437 Opposite Drive End 00649905 4 All Bearing- Roller,.437 Drive End 04954704 6 All Key- Wheel 5/8 X 6½ 0360 7 All Key- Fan Sheave 5/8 x 5½ 03607 35 All Wheel- SISW 040 36 All Funnel- Inlet 09480 37 All Lock Collar.437 04959 48 All Lock Washer 0486484 63 All Cap Screw 04049950 Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it with the Drive Components Cross Reference, form number 57006, or contact Daikin Applied with model and serial number information for identification.. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 38

Section A- Outdoor Air/Return Air/Economizer Section Return Air Fan Fan Mounts: Code = 44B* Until /04 Mounting Layout Diagram 6 OR 6 6 OR 6 63 OR 63 64 OR 64 89 90 9 9 6 6 63 64 9 Rubber Mounts Rubber Mounts (Code = 44B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support 05550 4 6 5-40 Rubber Mount- Red 063970 50, 60 Rubber Mount- Black 0639704 6 5-40 Rubber Mount- Red 063970 50, 60 Rubber Mount- Black 0639704 63 All Rubber Mount- Red 063970 64 All Rubber Mount- Red 063970 89 All Screw- Cap, 3/8-6 X 0488788 8 90 All Washer- Lock, 3/8 048648 8 9 All Nut- /-3 03333305 9 All Screw- Cap, /-3 X 04049950 8 93 All Washer- Plain, / 04050030 8 88 89 90 3 60 55 6 6 56 63 64 Spring Mounts Spring Mounts (Code = 44B) & Seismic Spring (44B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Support Assembly 05560690 4 All Screw Adjust Assembly 055580 4 3 All Channel Assembly 05560680 4 55 All Plate- Gasket Retainer 055500 4 56 All Support- Spring Locator 055500 4 60 All Pad- Rubber Vibration 04844790 4 6 5-30 Mount- Spring, Red 048448503 40-60 Mount- Spring, Green 048448504 6 5-30 Mount- Spring, Red 048448503 40-60 Mount- Spring, Green 048448504 63 All Mount- Spring, Red 048448503 64 All Mount- Spring, Red 048448503 88 All Nut- 5/8-04050000 4 89 All Screw- Cap, 3/8-6 X 0488788 90 All Washer- Lock, 3/8 048648 8 N/S All Screw- Tapping, /4-0 046093809 8 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 39

Section A- Outdoor Air/Return Air/Economizer Section Return Air Fan Fan Mounts: Code = 44B* /04 & Later Mounting Layout Diagram 6 OR 6 6 OR 6 63 OR 63 64 OR 64 9 89 93 88 89 8 8 9 9 Rubber Mounts 6 6 Spring Mounts 63 64 Seismic strap used only when Code 3= 44B3. 6 6 63 64 Rubber Mounts (Code = 44B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support 05550 4 6 5-40 Rubber Mount- Red 063970 50, 60 Rubber Mount- Black 0639704 6 5-40 Rubber Mount- Red 063970 50, 60 Rubber Mount- Black 0639704 63 All Rubber Mount- Red 063970 64 All Rubber Mount- Red 063970 8 All Nut 059990 8 89 All Screw 0470 8 9 All Nut- /-3 03333305 9 All Screw- Cap, /-3 X 04049950 8 93 All Washer- Plain, / 04050030 8 Spring (Code = 44B) & Seismic Mounts (Code = 44B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code = 44B) 57830 4 Seismic (Code = 44B3) 578330 4 6 5-0 Spring Mount- Brown 578480 5-30 Spring Mount- Red 578490 40-60 Spring Mount- Red/Black 578500 6 5-0 Spring Mount- Brown 578480 5-60 Spring Mount- Red 578490 63 5-0 Spring Mount- Brown 578480 5-30 Spring Mount- Red 578490 40-60 Spring Mount- Red/Black 578500 64 5-0 Spring Mount- Brown 578480 5-60 Spring Mount- Red 578490 8 All Nut Spring (Code = 44B) 059990 Seismic (Code = 44B3) 05630 0 88 All Nut 04050000 4 89 All Screw Spring (Code = 44B) 0470 Seismic (Code = 44B3) 0470 0 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 40

Section A- Outdoor Air/Return Air/Economizer Section Return Air Fan Motors Standard Motors: Code = **Y H.P. Motor HP Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff C=**Y Voltage C= *EY C= *JY C= *GY C= *KY C09= 3 H*Y 08/60/3 039447500 0658700 04735800 06589400 5 J*Y 08/60/3 039447600 0658700 04986800 06589500 7.5 K*Y 08/60/3 037530300 06587300 047665900 06589600 0 L*Y 08/60/3 038999000 06587400 04766600 06589700 5 M*Y 08/60/3 03989600 06587500 04986900 06589800 0 N*Y 08/60/3 039895800 06587600 04987000 06589900 5 P*Y 08/60/3 039448900 06587700 0498700 06580000 30 Q*Y 08/60/3 0477500 05066500 0498700 05066800 40 R*Y 08/60/3 04775300 0506700 04987300 05070700 50 S*Y 08/60/3 04775400 05067500 04987400 0509600 60 T*Y 08/60/3 04775800 05067700 04987500 N/A C09= 9 3 H*Y 30/60/3 03944400 0658800 0496300 0658000 5 J*Y 30/60/3 03944500 0658800 040600 0658000 7.5 K*Y 30/60/3 039448700 06588300 04900500 06580300 0 L*Y 30/60/3 039446500 06588400 0446900 06580400 5 M*Y 30/60/3 039446600 06588500 038689700 06580500 0 N*Y 30/60/3 039448800 06588600 0406300 06580600 5 P*Y 30/60/3 03989600 06588700 0406400 06580700 30 Q*Y 30/60/3 04066800 05066600 04905300 05066900 40 R*Y 30/60/3 04770000 0506700 048448000 0506900 50 S*Y 30/60/3 03989900 05067600 0406600 05069400 60 T*Y 30/60/3 04775500 0658900 046748300 N/A C09= 7 3 H*Y 460/60/3 03944400 0658800 0496300 0658000 5 J*Y 460/60/3 03944500 0658800 040600 0658000 7.5 K*Y 460/60/3 039448700 06588300 04900500 06580300 0 L*Y 460/60/3 039446500 06588400 0446900 06580400 5 M*Y 460/60/3 039446600 06588500 038689700 06580500 0 N*Y 460/60/3 039448800 06588600 0406300 06580600 5 P*Y 460/60/3 03989600 06588700 0406400 06580700 30 Q*Y 460/60/3 04066800 05066600 04905300 05066900 40 R*Y 460/60/3 04770000 0506700 048448000 0506900 50 S*Y 460/60/3 03989900 05067600 0406600 05069400 60 T*Y 460/60/3 04775500 0658900 046748300 05069600 C09= 37 3 H*Y 575/60/3 04674600 0465700 04988300 04654500 5 J*Y 575/60/3 04674900 0568900 04988400 04654600 7.5 K*Y 575/60/3 047443300 0568800 04988500 04654700 0 L*Y 575/60/3 047443400 0568600 04988600 0658400 5 M*Y 575/60/3 047443500 0566600 0498500 0658500 0 N*Y 575/60/3 049800 0566800 04988700 0658600 5 P*Y 575/60/3 049800 0566900 04988800 0658700 30 Q*Y 575/60/3 0498300 05066700 04988900 05067000 40 R*Y 575/60/3 0498400 05067300 04989000 05069300 50 S*Y 575/60/3 0498500 0509800 0498900 05069500 60 T*Y 575/60/3 0498600 05069000 0498900 05069800 N/A= Not Available. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Section A- Outdoor/Return Air Section Return Air Fan Motors Shaft Grounded Motors: Code = **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C= **S Voltage C= *JS C= *KS 3 H*S 08/60/3 3000509 06589499 5 J*S 08/60/3 300058 06589599 7.5 K*S 08/60/3 06587399 06589699 0 L*S 08/60/3 06587499 06589799 5 M*S 08/60/3 06587599 06589899 0 N*S 08/60/3 06587699 06589999 5 P*S 08/60/3 06587799 06580099 30 Q*S 08/60/3 05066599 05066899 40 R*S 08/60/3 0506799 05070799 50 S*S 08/60/3 05067599 0509699 60 T*S 08/60/3 05067799 N/A 3 H*S 30/60/3 300049698 300049688 5 J*S 30/60/3 300049699 300049689 7.5 K*S 30/60/3 300049700 300049690 0 L*S 30/60/3 30004970 06580499 5 M*S 30/60/3 06588599 30004998 0 N*S 30/60/3 06588699 30004969 5 P*S 30/60/3 30004970 30004969 30 Q*S 30/60/3 300049703 05066999 40 R*S 30/60/3 300049704 300049693 50 S*S 30/60/3 300049705 300049694 60 T*S 30/60/3 0658999 05069699 3 H*S 460/60/3 300049698 300049688 5 J*S 460/60/3 300049699 300049689 7.5 K*S 460/60/3 300049700 300049690 0 L*S 460/60/3 30004970 06580499 5 M*S 460/60/3 06588599 30004998 0 N*S 460/60/3 06588699 30004969 5 P*S 460/60/3 30004970 30004969 30 Q*S 460/60/3 300049703 05066999 40 R*S 460/60/3 300049704 300049693 50 S*S 460/60/3 300049705 300049694 60 T*S 460/60/3 0658999 05069699 3 H*S 575/60/3 0465799 0568499 5 J*S 575/60/3 0568999 04654699 7.5 K*S 575/60/3 0568899 04654799 0 L*S 575/60/3 0568699 0658499 5 M*S 575/60/3 0566699 0658599 0 N*S 575/60/3 0566899 0658699 5 P*S 575/60/3 0566999 0658799 30 Q*S 575/60/3 098865399 05067099 40 R*S 575/60/3 05067399 05069399 50 S*S 575/60/3 0509899 05069599 60 T*S 575/60/3 05069099 05069699 N/A= Not Available. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Section A- Outdoor Air/Return Air/Economizer Section Section Mounted Controls OAE, OAT, RAE, RAT, SD, LT, S, REC Bottom Return Shown Code 9= BY, BE Bottom Return Shown Code 9= BY, BE OAT Sensor Back Return (Code 9= HY) Economizer Damper Economizer Damper 4 48 30 558 558 Return Air Opening RAT Sensor 30 40 40 Return Air Opening Bottom Return (Code 9= BY, BE) 84 85 86 87 88 89 4 4 OAE- Mechanical Enthalpy (Code 7= Y*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE The original control is obsolete & no longer available. For the OAE Control use p/n 30360 & Mount 904657. Minor field modifications are required for proper installation & operation when changing to the newer design. OAE & RAE Differential Enthalpy (Code 7= C*) Ref. Part Part Qty. No. Description Number 40 Mount- OAE Enthalpy 4 Control- OAE 4 Mount- RAE Enthalpy 48 Control- RAE Note that BOTH original controls are obsolete & no longer available. For the OAE Control use 30360 & Mount p/n 904657. For the RAE Control use 30370 & Mount p/n 0557330. When changing one of the older style controls BOTH CONTROLS MUST BE CHANGED TO THE NEWER VERSION since the old and new parts are NOT compatible with each other. Also, minor field modifications are required for proper installation & operation when changing to the newer design. RAT/OAT- Return/Outdoor Air Temperature Sensor Ref. Part Part Qty. No. Description Number 558 RA/OA Air Temp. Sensor- RAT (MTII) 060004705 RA/OA Air Temp. Sensor- RAT (MTIII) 934460 SD- Return Air Smoke Detector (Code 6=, 3) Ref. Part Part Qty. No. Description Number 30 Smoke Detector (SD) 0988730 When replacing SD, reuse existing Sampling Tubes or order pc. 0988730 for Standard Discharge OR pc. of 09887350 for Side or Top Discharge. LT- Return Fan Light/S- Return Fan Light Switch/ REC- Return Fan Receptacle Code 49= E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture 049500 85 Bulb- LT 0654940 86 Junction Box 0654990 87 Junction Box Cover 0654900 88 Light Switch- S 065490 89 Receptacle- REC 03087000 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 43

Section B- Draw-Thru Filter Section Notes & Section Mounted Controls Primary Codes that pertain: 5, 33 (Mid 0 & Later) Additional Codes that pertain: 06, 9, 0 Notes Code 5 determines all of the section characteristics. Refer to the Nomenclature, Unit Code Index section for an explanation of Filter codes. Code 33 (Mid 0 & Later) indicates the presence of Magnehelic/Differential Pressure Gauges. Code 06 determines the final assembly panel part numbers. For sheet metal components that make up the Draw-Thru Filter Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Codes 9 and 0 determine the Return Air Section which has an effect on the final assembly panels. Section Mounted Controls PC5, LT3, S3, REC3, Magnehelic/Differential Pressure Gauges Controls PC5 Ref. Part Part Qty. No. Description Number 65 PC5 Pressure Ctl 06549380 65 84 85 86 87 88 89 LT3- Filter Section Light; S3- Filter Section Light Switch; REC3- Filter Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture 049500 85 Bulb- LT3 0654940 86 Junction Box 0654990 87 Junction Box Cover 0654900 88 Light Switch- S3 065490 89 Receptacle- REC3 03087000 3396 Magnehelic/Differential Pressure Gauge Code 33= A****, B****, C**** (Mid 0 & Later) Ref. Part Part No. Description Number 3396 Differential Press. Gauge, 0-3 WC 09887303 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 44

Section B- Draw-Thru Filter Section Filters Typical Angular Filter Section Shown Code 5= A* Ref. Part Code Part Qty. No. Description 5= Number Angular Filter Section (Code 5= A*, D*, E*, G*) N/S Filter 30% Pleated, 6 x 5 x " MERV 8 *B 046306 33 30% Pleated, 6 x 5 x " w/ Intersept MERV 8 *C 039800 33 85% Disposable, 6 x 5 x MERV 3 *H 90050 33 N/S Filter 30% Pleated, 6 x 0 x MERV 8 *B 046305 30% Disposable, 6 x 0 x " w/ Intersept MERV 8 *C 046505 85% Disposable, 6 x 0 x MERV 3 *H 9005 N/S Media Filler Piece ALL 04840 N/S Angle Assembly ALL 05607730 33 Flat Filter Section (Code 5= F*, H*) N/S Filter, Cartridge 65% Cartridge, 4 x 4 x " MERV *D 06580704 95% Cartridge, 4 x 4 x " MERV 4 *E 0658070 95% Cartridge, 4 x 4 x " w/ Intersept MERV 4 *G 066305 85% Disposable, 4 x 4 x MERV 3 *H 900394 Gasket, Cartridge 5/8 x /6 x 4 ALL 076894 N/S Filter, Cartridge 65% Cartridge, x 4 x " MERV *D 06580703 4 95% Cartridge, x 4 x " MERV 4 *E 0658070 4 95% Cartridge, x 4 x " w/ Intersept MERV 4 *G 0663053 4 85% Disposable, x 4 x MERV 3 *H 900399 4 Gasket, Cartridge 5/8 x /6 x ALL 07689 4 N/S Pre Filter, 4 x 4 x ALL 0460 Gasket, Pre Filter ALL 05900 4 N/S Pre Filter, x 4 x ALL 04603 4 Gasket, Pre Filter ALL 05900 8 Note that MERV ratings have changed during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters. Optional- Angle is mounted on leaving air side. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 45

Section B- Draw-Thru Filter Section Filters, Continued Ref. Part Code Part Qty. No. Description 5= Number Staggered Filter Section (Code 5= S*, T*, V*) 65% Cartridge, 4 x 4 x MERV *D 06580704 6 95% Cartridge, 4 x 4 x MERV 4 *E 0658070 6 95% Cartridge, 4 x 4 x w/ Intersept MERV 4 *G 066305 6 85% Disposable, 4 x 4 x MERV 3 *H 900394 6 Gasket, Cartridge 5/8 x /6 x 4 ALL 076894 6 N/S Filter, Cartridge 65% Cartridge, x 4 x MERV *D 06580703 4 95% Cartridge, x 4 x MERV 4 *E 0658070 4 95% Cartridge, x 4 x w/ Intersept MERV 4 *G 0663053 4 85% Disposable, x 4 x MERV 3 *H 900399 4 Gasket, Cartridge 5/8 x /6 x ALL 07689 8 N/S Pre Filter, 4 x 4 x ALL 0460 6 Gasket, Pre Filter ALL 05900 3 Staggered Filter Section (Code 5= L*) 65% Cartridge, 4 x 4 x MERV *D 06580704 6 95% Cartridge, 4 x 4 x MERV 4 *E 0658070 6 95% Cartridge, 4 x 4 x w/ Intersept MERV 4 *G 066305 6 85% Disposable, 4 x 4 x MERV 3 *H 900394 6 Gasket, Cartridge 5/8 x /6 x 4 ALL 076894 8 N/S Filter, Cartridge 65% Cartridge, x 4 x MERV *D 06580703 8 95% Cartridge, x 4 x MERV 4 *E 0658070 8 95% Cartridge, x 4 x w/ Intersept MERV 4 *G 0663053 8 85% Disposable, x 4 x MERV 3 *H 900399 8 Gasket, Cartridge 5/8 x /6 x ALL 07689 8 N/S Pre Filter, 4 x 4 x ALL 0460 6 Gasket, Pre Filter ALL 05900 3 N/S Pre Filter, x 4 x ALL 04603 8 Gasket, Pre Filter ALL 05900 6 Note that MERV ratings have changed during the production run, so some lower rated filters may no longer be available. Higher MERV filters can be used as a substitute for lower rated filters. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 46

Section C- Blank/Inverter (AFD/VFD) Section Notes & Section Mounted Controls Primary Codes that pertain: 6, 4, 5 Additional Codes that pertain: 06 Notes Code 6 determines if a Blank/Inverter Section is installed. If Code 6= F, S there is a 48 section. If Code 6= E there is a 4 section installed. If Code 6= Y, there is no Blank/Inverter Section. Codes 4 & 5 determine if the unit has inverter(s) and if so where they are installed. If Code 4=,, 4 AND Code 6= E, F there is a separate Inverter Section. If Code 4= 3, 5, 6, 7, 8, 9, the inverter(s) are installed in the Supply Air Section. If Code 4= Y, there are no inverters. Code 5 identifies the inverter brand supplied. If Code 5= F, the unit is set up for a field supplied Inverter. If Code 5= F, contact Daikin Applied with the Inverter vendor and vendor part number to see if a replacement can be supplied. All components pertaining to the inverters are listed in the Supply Air Section (Section F). Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blank/Inverter Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Section Mounted Controls 84 85 86 87 88 89 LT9- Blank/Inverter Section Light; S9- Blank/ Inverter Section Light Switch; REC9- Blank/ Inverter Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture 049500 85 Bulb- LT9 0654940 86 Junction Box 0654990 87 Junction Box Cover 0654900 88 Light Switch- S9 065490 89 Receptacle- REC9 03087000 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 47

Section D- Draw-Thru Cooling Section Notes Primary Codes that pertain: 03, 7, 8, 36 Additional Codes that pertain: 06 Code 03 determines the Cooling Coil size. If Code 03= S there is a small face area Coil (4 section for unit sizes 076 thru 00C, or normally a 48 section for unit size 0C although a few units have a 4 section installed). If Code 03= L it is a large face area Coil (48 section for unit sizes 076 thru 00C, or 4/48 for unit sizes 0C thru 50C). Small face area Coils are not available on 30 thru 50C unit sizes. Code 7 determines the characteristics of the Draw-Thru Cooling Section. If Code 7= YYYY, there is no Section. For RPE units this indicates that the Cooling Coil is in the Blow-Thru position (see Section I); RDE units (typical RDE unit shown in the above diagram) always have a Draw-Thru Cooling Section. If the code is CYYY, CYYS then there is a unit Cooling Coil and Drain Pan. An S in the fourth position of Code 7 means the Drain Pan is stainless steel. A Y in the fourth position indicates that the Drain Pan is made of painted galvanized steel. Code 8 determines the Cooling Coil characteristics. Code 8 will apply only if Code 7= CYYY, CYYS AND Code 36= YYYYYY. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Draw-Thru Cooling Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. NOTE: The drawings and components listed in this section also apply to Section I Blow-Thru Cooling Section (RPE only). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 48

Section D- Draw-Thru Cooling Section Evaporator Coils & Drain Pans, Small Face DX Evaporator Coils: Code 03= S Small Face Area Coil 4 Section Unit Sizes 076 thru 0C 400 Ref. Part Part Qty. No. Description Number Coil 300 Drain Pan Galvanized (C7= CYYY) 0566775 Stainless (C7= CYYS) 0566775 400 Pan- Auxilliary Before /06 Stainless (C7= CYYS) 05735680 After /06 Stainless (C7= CYYS) 05735680 300 Small Face Area Coil 48 Section Unit Size 0C 490 450 Ref. Part Part Qty. No. Description Number Coil- Upper Coil- Lower 400 Drain Pan Galvanized (C7= CYYY) 05667755 Stainless (C7= CYYS) 05667756 450 Pan- Auxilliary 056740 480 Pan- Liner 055530 490 Drain Pan Galvanized (C7= CYYY) 05667755 Stainless (C7= CYYS) 05553354 400 480 Evaporator coils are serial number specific. Contact Daikin Applied with model and serial number information so that the correct coil(s) can be identified. 0C units may have either a 4 OR a 48 Section installed. Confirm section size before ordering or contact Daikin Applied with model and serial number information so that the correct coil(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 49

Section D- Draw-Thru Cooling Section Evaporator Coils & Drain Pans, Large Face DX Evaporator Coils: Code 03= L Large Face Area Coil 48 Section 490 450 Ref. Part Part Qty. No. Description Number Coil- Lower Coil- Upper 400 Drain Pan Galvanized (C7= CYYY) 05667755 Stainless (C7= CYYS) 05667756 450 Pan- Auxilliary 056740 480 Pan- Liner 055530 490 Drain Pan Galvanized (C7= CYYY) 0963500 Stainless (C7= CYYS) 05553354 400 480 Large Face Area Coil 4/48 Section 490 450 Ref. Part Part Qty. No. Description Number Coil- Lower Coil- Upper 400 Drain Pan Galvanized (C7= CYYY) 0566775 Stainless (C7= CYYS) 0566775 450 Pan- Auxilliary 056740 480 Pan- Liner 055530 490 Drain Pan Galvanized (C7= CYYY) 0963500 Stainless (C7= CYYS) 05553354 400 480 Evaporator coils are serial number specific. Contact Daikin Applied with model and serial number information so that the correct coil(s) can be identified. 089 thru 50C units may have either a 48 OR a 4/48 (7 OAL) section installed. Confirm section size before ordering or contact Daikin Applied with model and serial number information so that the correct coil(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 50

Section E- 48 Draw-Thru Spacer/Blank Section Notes Primary Codes that pertain: 6, 30 Additional Codes that pertain: 06 Code 6 & 30 determine all of the section characteristics. If Code 6= F, S AND/OR Code 30= BBBBBB there is a 48 Blank/Spacer Section. If Code 6= E AND/OR Code 30= EEEEEE there is a 4 Blank/Spacer Section. If Code 6= Y AND/OR Code 30= YYYYYY, there is no section. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the 48 Draw-Thru Spacer/Blank Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Section E- Draw-Thru Heat Section for RDE Units Notes Primary Codes that pertain: 04, 30 Additional Codes that pertain: 06 Code 04 determines what type of heat was specified. Draw-Thru Heat units typically are hydronic with Hot Water (Code 04= H) OR Steam (Code 04= S) heat. If Code 04= E (Electric Heat), contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Code 30 determines the Hydronic Heating Coil and associated Valve characteristics OR Electric Heat specifications. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the 48 RDE Draw-Thru Heat Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Section Mounted Controls 84 85 86 87 88 89 LT8- Draw-Thru Heat Light; S8- Draw-Thru Heat Light Switch; REC8- Draw-Thru Heat Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture 049500 85 Bulb- LT8 0654940 86 Junction Box 0654990 87 Junction Box Cover 0654900 88 Light Switch- S8 065490 89 Receptacle- REC8 03087000 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Section E- Draw-Thru Heat Section for RDE Units Hot Water & Steam Heat Coils, Mixing Valves, & Actuator VM Code 30= W***, W***, OR S***, S***, S3***, S4*** Coil Location Mixing Valve Detail Air Flow 3 65 64 63 Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 30= Type Height Number Hot Water Heat Coil- Bottom W*** 5WH090H 4 056053065 Hot Water Heat Coil- Bottom W*** 5WS090C 4 056053066 3 Hot Water Heat Coil- Top W*** 5WH090H 39 056053045 Hot Water Heat Coil- Top W*** 5WS090C 39 056053046 63 Valve, 3 Way- Hot Water Heat.5 W**E3* ALL ALL 047936505.50 W**F3* ALL ALL 04793650.00 W**G3* ALL ALL 04793650.50 W**H3* ALL ALL 047936506 3.00 W**J3* ALL ALL 047936503 64 Linkage-.5 thru.00 Valve *****E ALL ALL 0497640 Linkage-.50, 3.00 Valve *****E ALL ALL 04976403 65 VM Actuator 0V *****E ALL ALL 059999804 For Steam Heat Coils and Components (Code 30= S*****) contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Hot Water Heat 3.00 Valve uses Flange Gasket p/n: 0336000. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Section F- Supply Air Section Notes Primary Codes that pertain: 3, 3, 33 (Mid 0 & Earlier), 59 (Mid 0 & Later) Additional Codes that pertain: 04, 06, 08, 4, 5, 34, 40, 49 Code 3 determines the Supply Fan size, type, and mounting method. RPE units can have a 33, 36, 40 Airfoil OR Forward Curved Wheel. If the unit is equipped with a Forward Curved Wheel (Code 3= **F*, **M*) contact Daikin Applied so that the required part(s) can be identified. RDE units can have either a 44 OR a 49 Airfoil Wheel. Digit four of Code 3 indicates the Fan Mounting type. If digit four is a the unit has Rubber-In-Shear (RIS) isolators. If digit four is a the unit has Spring Isolators. If digit four is 3 the unit has Spring Isolators with Seismic Snubbers. Code 3 determines the Supply Fan Motor horsepower and type. Fan Motors range from 5.0-75 horsepower. Note that 75 horsepower Motors are NOT available in (Code 09= ) OR (Code 09= 9). Code 33 (Mid 0 & Earlier) OR Code 59 (Mid 0 & Later) determine the Drive Components selected. Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is required you may use the number from the part and cross reference it with the Drive Components Cross Reference, form number 57006, or contact Daikin Applied with model and serial number information for identification. Code 04 AND Code 34 determine the heat type, which can affect the final assembly part numbers, the location of the discharge plenum, as well as the section installed controls. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Supply Air Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Code 08 determines the location of the unit s Main Control Box. RDE units with no Blow-Thru Section have their Main Control Boxes in the Supply Air Section. Codes 4 & 5 determine if the unit has Inverter(s) and if so where they are installed. If Code 4= 3, 5, 6, 7, 8, 9 the Inverter(s) are installed in the Supply Air Section. If Code 4=,, 4 AND Code 6= E, F, S, there is a separate Inverter Section. If Code 4= Y, there are no factory supplied Inverters. Code 5 references which Inverter vendor was selected. If Code 5= F, the unit is set up for a field supplied Inverter. If Code 5= F, contact Daikin Applied with the Inverter vendor and vendor part number to see if a replacement can be supplied. All components pertaining to the Supply and Return Air Inverters are listed in this section. Code 40 determines the Discharge Plenum configuration. RDE units always have the Discharge Plenum located in Section F. If Code 40= BE, there is an Isolation Damper with Actuator ACT5. The Isolation Damper and related components are detailed in the Discharge Plenum Section (Section K). Code 49 determines if the Supply Air section is supplied with a Belt Guard (Code 49= A, D), a Fan Section Light (Code 49= B, E), or both (Code 49= C, F). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 53

Motor (See Motor list after Fan Mount section.) Section F- Supply Air Section Air Foil Fan, Double Width Code 3= 33A*, 36A*, 40A* 7 5 8 7 5 Inlet Funnel 3 6 4 5 Cut Off Plates Ref. Part Part Fan Size No Description Number 33 36 40 Housing Assy- Blower (Code 3= 33A*) 05557704 Inlet Funnel only 03940903 Cut Off Plate only 03636000 Housing Assy- Blower (Code 3= 36A*) 05557705 Inlet Funnel only 03940904 Cut Off Plate only 0363600 Housing Assy- Blower (Code 3= 40A*) 05557706 Inlet Funnel only 03940905 Cut Off Plate only 0363600 3 Wheel, Fan- Single Inlet Single Width CW 06654305 Wheel, Fan- Single Inlet Single Width CW 06654307 Wheel, Fan- Single Inlet Single Width CW 06654309 4 Wheel, Fan- Single Inlet Single Width CCW 06654306 Wheel, Fan- Single Inlet Single Width CCW 06654308 Wheel, Fan- Single Inlet Single Width CCW 0665430 5 Screw Adjust Assembly 055580 Shaft-.438 Diameter 0555570 Shaft-.688 Diameter 055667303 Shaft-.938 Diameter 0556440 5 Motor Mount Assembly 0560450 6 Angle- Motor Mount 055540 7 Holddown 047900 8 Angle, Clamping 05557660 Key- Fan 4.75 Long X 5/8 Diameter 0367 Key- Fan 0.00 Long X 5/8 Diameter 0363 Key- Fan 5.50 Long X 3/4 Diameter 0370 Key- Sheave 6.50 Long X / Diameter 0360 Key- Sheave 5.50 Long X 3/4 Diameter 0370 5 Bearing- Ball.437 Bore 00648655 Bearing- Ball.688 Bore 00648658 Bearing- Ball.938 Bore 00648659 Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is needed use the number from the part and cross reference it with the Cross Reference: Drive Components Form number: 57006, or contact Daikin Applied to ensure that the required part(s) are correctly identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 54

Section F- Supply Air Section Air Foil Fan, Single Width Code 3= 44B*, 49B* 3 6 4 4 5 7 38 5 7 Motor (See Motor list after Fan Mount section.) 6 5 Ref. Part Part Fan Size No. Description Number 44 49 3 Wheel, Fan- Single Inlet/Single Width 09400 Wheel, Fan- Single Inlet/Single Width 0940 4 Inlet Funnel Assembly 09480 Inlet Funnel Assembly 0948 5 Screw Adjust Assembly 0555803 Shaft-.438 Diameter 05553470 Shaft-.88 Diameter 05607980 5 Mount Assembly-Motor 0560450 6 Angle- Motor Mount 055540 7 Angle, Clamping 055570 Key- Fan, 6.50 Long X 5/8 Diameter 0360 Key- Fan, 6.00 Long X / Diameter 0350 Key- Fan, 5.50 Long X 5/8 Diameter 03607 Key- Fan, 6.00 Long X / Diameter 0350 4 Tubing- Plastic 036795 Tubing- Plastic 036798 5 Bearing- Ball,.437 Bore 00648655 Bearing- Ball,.88 Bore 00648654 6 Fitting- /4 OD X /8 MPT 07674000 7 Fitting- /4 OD X /8 FPT 0767400 38 Bearing- Ball,.437 Bore 00648655 Bearing- Roller,.88 Bore 0495408 Drive components (Fan Sheave, Motor Sheave, V-belt(s), and Sheave Bushing(s) [if required]) are NOT listed as they are unique to the unit. If a drive component is needed use the number from the part and cross reference it with the Cross Reference: Drive Components Form number: 57006, or contact Daikin Applied to ensure that the required part(s) are correctly identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 55

Section F- Supply Air Section Fan Mounts- 33 Airfoil Double Width Fan Code 3= 33A, 33A, 33A3 Mounting Layout Diagram 3 OR 3 33 OR 33 3 OR 3 34 OR 34 9 9 3 3 93 33 34 89 9 8 Rubber Mounts Rubber Mounts (Code 3= 33A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support 0983600 4 3 5, 7.5 Rubber Mount- Black 0639704 0-50 Rubber Mount- Red 063970 3 All Rubber Mount- Black 0639704 33 5-5 Rubber Mount- Red 063970 30-50 Rubber Mount- Green 0639703 34 5-5 Rubber Mount- Black 0639704 30-50 Rubber Mount- Red 063970 8 All Nut 059990 8 89 All Screw 0470 8 9 All Nut, /-3 03333305 9 All Screw- Cap, /-3 X 04049950 8 93 All Washer- Plain, / 048648 8 88 89 8 Spring Mounts Seismic strap used only when Code 3= 33A3. 3 3 33 34 Spring (Code 3= 33A) & Seismic Mounts (Code 3= 33A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code 3= 33A) 57830 4 Seismic (Code 3= 33A3) 578330 4 3 5, 7.5 Spring Mount- Green 578470 0-30 Spring Mount- Brown 578480 40, 50 Spring Mount- Red 578490 3 All Spring Mount- Brown 578480 33 5, 7.5 Spring Mount- Brown 578480 0-30 Spring Mount- Red 578490 40, 50 Spring Mount- Red/Black 578500 34 All Spring Mount- Red 578490 8 All Nut Spring (Code 3= 33A) 059990 Seismic (Code 3= 33A3) 05630 0 88 All Nut 04050000 4 89 All Screw Spring (Code 3= 33A) 0470 Seismic (Code 3= 33A3) 0470 0 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 56

Section F- Supply Air Section Fan Mounts- 36 Airfoil Double Width Fan Code 3= 36A, 36A, 36A3 Until /04 Mounting Layout Diagram 3 OR 3 33 OR 33 3 OR 3 34 OR 34 9 93 89 90 9 9 3 3 33 34 Rubber Mounts (Code 3= 36A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support 0983600 4 3 All Rubber Mount- Red 063970 3 0, 30-50 Rubber Mount- Red 063970 0, 60, 75 Rubber Mount- Black 0639704 33 0-5 Rubber Mount- Red 063970 30-50 Rubber Mount- Green 0639703 60, 75 Rubber Mount- Gray 0639705 34 All Rubber Mount- Red 063970 89 All Screw- Cap, 3/8-6 X 0488788 8 90 All Washer- Lock, 3/8 048648 8 9 All Nut, /-3 03333305 9 All Screw- Cap, /-3 X 04049950 8 88 89 90 3 55 56 60 3 3 33 34 Spring Mounts (Code 3= 36A, 36A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Support Assembly 05560690 4 All Screw Adjust Assembly 055580 4 3 All Channel Assembly 05560680 4 3 0-60 Mount- Spring, Red 048448503 75 Mount- Spring, Green 048448504 3 0 Mount- Spring, Red 048448503 5-60 Mount- Spring, Dk. Yellow 04844850 75 Mount- Spring, Blue 04844850 33 0-0 Mount- Spring, Red 048448503 5-75 Mount- Spring, Green 048448504 34 All Mount- Spring, Red 048448503 55 All Plate- Gasket Retainer 055500 4 56 All Support- Spring Locator 055500 4 60 All Pad- Rubber Vibration 04844790 4 88 All Nut, 5/8-04050000 4 89 All Screw- Cap, 3/8-6 X 0488788 90 All Washer- Lock, 3/8 048648 8 N/S All Screw- Tapping, /4-0 046093809 8 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 57

Section F- Supply Air Section Fan Mounts- 36 Airfoil Double Width Fan Code 3= 36A, 36A, 36A3 /04 & Later Mounting Layout Diagram 3 OR 3 33 OR 33 3 OR 3 34 OR 34 9 89 93 88 89 8 8 9 9 Rubber Mounts Spring Mounts 3 3 33 34 Seismic strap used only when Code 3= 36A3. 3 3 33 34 Rubber Mounts (Code 3= 36A, 36V) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support 0983600 4 3 All Rubber Mount- Red 063970 3 0, 30-50 Rubber Mount- Red 063970 0, 60, 75 Rubber Mount- Black 0639704 33 0-5 Rubber Mount- Red 063970 30-50 Rubber Mount- Green 0639703 60, 75 Rubber Mount- Gray 0639705 34 All Rubber Mount- Red 063970 8 All Nut 059990 8 89 All Screw 0470 8 9 All Nut, /-3 03333305 9 All Screw- Cap, /-3 X 04049950 8 93 All Washer- Plain, / 048648 8 Spring (Code 3= 36A) & Seismic Mounts (Code 3= 36A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code 3= 36A) 57830 4 Seismic (Code 3= 36A3) 578330 4 3 0, 5 Spring Mount- Brown 578480 0-50 Spring Mount- Red 578490 60, 75 Spring Mount- Red/Black 578500 3 All Spring Mount- Brown 578480 33 0, 5 Spring Mount- Red 578490 0-50 Spring Mount- Red/Black 578500 60, 75 Spring Mount- Red/Green 57850 34 0-0 Spring Mount- Red 578490 5-75 Spring Mount- Red/Black 578500 8 All Nut Spring (Code 3= 36A) 059990 Seismic (Code 3= 36A3) 05630 0 88 All Nut 04050000 4 89 All Screw Spring (Code 3= 36A) 0470 Seismic (Code 3= 36A3) 0470 0 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 58

Section F- Supply Air Section Fan Mounts- 40 Airfoil Double Width Fan Code 3= 40A, 40A, 40A3 Mounting Layout Diagram 3 OR 3 33 OR 33 3 OR 3 34 OR 34 9 89 93 88 89 8 8 9 9 Rubber Mounts Spring Mounts 3 3 33 34 Seismic strap used only when Code 3= 40A3. 3 3 33 34 Rubber Mounts (Code 3= 40A) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support 0983600 4 3 0-50 Rubber Mount- Red 063970 60, 75 Rubber Mount- Green 0639703 3 0-30 Rubber Mount- Red 063970 40-75 Rubber Mount- Black 0639704 33 0, 5 Rubber Mount- Red 063970 0-50 Rubber Mount- Green 0639703 60, 75 Rubber Mount- Gray 0639705 34 All Rubber Mount- Red 063970 8 All Nut 059990 8 89 All Screw 0470 8 9 All Nut, /-3 03333305 9 All Screw- Cap, /-3 X 04049950 8 93 All Washer- Plain, / 048648 8 Spring (Code 3= 40A) & Seismic Mounts (Code 3= 40A3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code 3= 40A) 57830 4 Seismic (Code 3= 40A3) 578330 4 3 0 Spring Mount- Brown 578480 5-30 Spring Mount- Red 578490 40-75 Spring Mount- Red/Black 578500 3 All Spring Mount- Brown 578480 33 0 Spring Mount- Red 578490 5-30 Spring Mount- Red/Black 578500 40-75 Spring Mount- Red/Green 57850 34 0-0 Spring Mount- Red 578490 5-75 Spring Mount- Red/Black 578500 8 All Nut Spring (Code 3= 40A) 059990 Seismic (Code 3= 40A3) 05630 0 88 All Nut 04050000 4 89 All Screw Spring (Code 3= 40A) 0470 Seismic (Code 3= 40A3) 0470 0 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 59

Section F- Supply Air Section Fan Mounts- 44 Airfoil Single Width Fan Code 3= 44B, 44B, 44B3 Mounting Layout Diagram 3 OR 33 OR 3 33 3 OR 3 34 OR 34 9 9 3 3 93 33 34 89 9 8 Rubber Mounts Rubber Mounts (Code 3= 44B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support 0983600 4 3 7.5-5 Rubber Mount- Black 0639704 30-60 Rubber Mount- Red 063970 3 All Rubber Mount- Red 063970 33 7.5, 0 Rubber Mount- Black 0639704 5-50 Rubber Mount- Red 063970 60 Rubber Mount- Green 0639703 34 All Rubber Mount- Red 063970 8 All Nut 059990 8 89 All Screw 0470 8 9 All Nut- /-3 03333305 9 All Screw- Cap, /-3 X 04049950 8 93 All Washer- Plain, / 048648 8 88 89 8 Spring Mounts Seismic strap used only when Code 3= 44B3. 3 3 33 34 Spring (Code 3= 44B) & Seismic Mounts (Code 3= 44B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code 3= 44B) 57830 4 Seismic (Code 3= 44B3) 578330 4 3 7.5-0 Spring Mount- Green 578470 5-50 Spring Mount- Brown 578480 60 Spring Mount- Red 578490 3 All Spring Mount- Brown 578480 33 7.5-5 Spring Mount- Brown 578480 30-50 Spring Mount- Red 578490 60 Spring Mount- Red/Black 578500 34 All Spring Mount- Red 578490 8 All Nut Spring (Code 3= 44B) 059990 Seismic (Code 3= 44B3) 05630 0 88 All Nut 04050000 4 89 All Screw Spring (Code 3= 44B) 0470 Seismic (Code 3= 44B3) 0470 0 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 60

Section F- Supply Air Section Fan Mounts- 49 Airfoil Single Width Fan Code 3= 49B, 49B, 49B3 Mounting Layout Diagram 3 OR 33 OR 3 33 3 OR 3 34 OR 34 9 9 3 3 93 33 34 89 9 8 Rubber Mounts Rubber Mounts (Code 3= 49B) Ref. Fan Motor Part Part Qty. No. HP Description Number All Channel- Mount Support 0983600 4 3 All Rubber Mount- Red 063970 3 All Rubber Mount- Red 063970 33 7.5-30 Rubber Mount- Red 063970 40-75 Rubber Mount- Green 0639703 34 7.5-30 Rubber Mount- Red 063970 40-75 Rubber Mount- Green 0639703 8 All Nut 059990 8 89 All Screw 0470 8 9 All Nut, /-3 03333305 9 All Screw- Cap, /-3 X 04049950 8 93 All Washer- Plain, / 048648 8 88 89 8 Spring Mounts Seismic strap used only when Code 3= 49B3. 3 3 33 34 Spring (Code 3= 49B) & Seismic Mounts (Code 3= 49B3) Ref. Fan Motor Part Part Qty. No. HP Description Number All Mount Spring (Code 3= 49B) 57830 4 Seismic (Code 3= 49B3) 578330 4 3 7.5-30 Spring Mount- Red 578490 40, 50 Spring Mount- Red/Black 578500 60, 75 Spring Mount- Red/Green 57850 3 All Spring Mount- Red/Black 578500 33 7.5-0 Spring Mount- Red 578490 5-75 Spring Mount- Red/Black 578500 34 All Spring Mount- Red/Black 578500 8 All Nut Spring (Code 3= 49B) 059990 Seismic (Code 3= 49B3) 05630 0 88 All Nut 04050000 4 89 All Screw Spring (Code 3= 49B) 0470 Seismic (Code 3= 49B3) 0470 0 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

H.P. Motor HP Unit ODP HiEff ODP PrEff. TEFC HiEff TEFC PrEff C3=**Y Voltage C3= *EY C3= *JY C3= *HY C3= *KY C09= 5 J*Y 08/60/3 039447600 0658700 04986800 06589500 7.5 K*Y 08/60/3 037530300 06587300 047665900 06589600 0 L*Y 08/60/3 038999000 06587400 04766600 06589700 5 M*Y 08/60/3 03989600 06587500 04986900 06589800 0 N*Y 08/60/3 039895800 06587600 04987000 06589900 5 P*Y 08/60/3 039448900 06587700 0498700 06580000 30 Q*Y 08/60/3 0477500 05066500 0498700 05066800 40 R*Y 08/60/3 04775300 0506700 04987300 05070700 50 S*Y 08/60/3 04775400 05067500 04987400 0509600 60 T*Y 08/60/3 04775800 05067700 04987500 N/A 75 U*Y 08/60/3 04775700 0506900 04987600 N/A C09= 9 5 J*Y 30/60/3 03944500 0658800 040600 0658000 7.5 K*Y 30/60/3 039448700 06588300 04900500 06580300 0 L*Y 30/60/3 039446500 06588400 0446900 06580400 5 M*Y 30/60/3 039446600 06588500 038689700 06580500 0 N*Y 30/60/3 039448800 06588600 0406300 06580600 5 P*Y 30/60/3 03989600 06588700 0406400 06580700 30 Q*Y 30/60/3 04066800 05066600 04905300 05066900 40 R*Y 30/60/3 04770000 0506700 048448000 0506900 50 S*Y 30/60/3 03989900 05067600 0406600 05069400 60 T*Y 30/60/3 04775500 0658900 046748300 05069600 75 U*Y 30/60/3 04775600 05070300 04987800 05069900 C09= 7 5 J*Y 460/60/3 03944500 0658800 040600 0658000 7.5 K*Y 460/60/3 039448700 06588300 04900500 06580300 0 L*Y 460/60/3 039446500 06588400 0446900 06580400 5 M*Y 460/60/3 039446600 06588500 038689700 06580500 0 N*Y 460/60/3 039448800 06588600 0406300 06580600 5 P*Y 460/60/3 03989600 06588700 0406400 06580700 30 Q*Y 460/60/3 04066800 05066600 04905300 05066900 40 R*Y 460/60/3 04770000 0506700 048448000 0506900 50 S*Y 460/60/3 03989900 05067600 0406600 05069400 60 T*Y 460/60/3 04775500 0658900 046748300 05069600 75 U*Y 460/60/3 04775600 05070300 04987800 05069900 C09= 37 5 J*Y 575/60/3 04674900 0568900 04988400 04654600 7.5 K*Y 575/60/3 047443300 0568800 04988500 04654700 0 L*Y 575/60/3 047443400 0568600 04988600 0658400 5 M*Y 575/60/3 047443500 0566600 0498500 0658500 0 N*Y 575/60/3 049800 0566800 04988700 0658600 5 P*Y 575/60/3 049800 0566900 04988800 0658700 30 Q*Y 575/60/3 0498300 05066700 04988900 05067000 40 R*Y 575/60/3 0498400 05067300 04989000 05069300 50 S*Y 575/60/3 0498500 0509800 0498900 05069500 60 T*Y 575/60/3 0498600 05069000 0498900 05069800 75 U*Y 575/60/3 0498800 05070400 04989300 05070000 N/A= Not Available. Section F- Supply Air Section Supply Air Fan Motors Standard Motors: Code 3= **Y RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

Section A- Outdoor/Return Air Section Supply Air Fan Motors Shaft Grounded Motors: Code 3= **S H.P. Motor HP Unit ODP PrEff. TEFC PrEff C3= **S Voltage C3= *JS C3= *KS C09= 5 J*S 08/60/3 300058 06589599 7.5 K*S 08/60/3 06587399 06589699 0 L*S 08/60/3 06587499 06589799 5 M*S 08/60/3 06587599 06589899 0 N*S 08/60/3 06587699 06589999 5 P*S 08/60/3 06587799 06580099 30 Q*S 08/60/3 05066599 05066899 40 R*S 08/60/3 0506799 05070799 50 S*S 08/60/3 05067599 0509699 60 T*S 08/60/3 05067799 N/A 75 U*S 08/60/3 0506999 N/A C09= 9 5 J*S 30/60/3 300049699 300049689 7.5 K*S 30/60/3 300049700 300049690 0 L*S 30/60/3 30004970 06580499 5 M*S 30/60/3 06588599 30004998 0 N*S 30/60/3 06588699 30004969 5 P*S 30/60/3 30004970 30004969 30 Q*S 30/60/3 300049703 05066999 40 R*S 30/60/3 300049704 300049693 50 S*S 30/60/3 300049705 300049694 60 T*S 30/60/3 0658999 05069699 75 U*S 30/60/3 30005354 3000574 C09= 7 5 J*S 460/60/3 300049699 300049689 7.5 K*S 460/60/3 300049700 300049690 0 L*S 460/60/3 30004970 06580499 5 M*S 460/60/3 06588599 30004998 0 N*S 460/60/3 06588699 30004969 5 P*S 460/60/3 30004970 30004969 30 Q*S 460/60/3 300049703 05066999 40 R*S 460/60/3 300049704 300049693 50 S*S 460/60/3 300049705 300049694 60 T*S 460/60/3 0658999 05069699 75 U*S 460/60/3 30005354 3000574 C09= 37 5 J*S 575/60/3 0568999 04654699 7.5 K*S 575/60/3 0568899 04654799 0 L*S 575/60/3 0568699 0658499 5 M*S 575/60/3 0566699 0658599 0 N*S 575/60/3 0566899 0658699 5 P*S 575/60/3 0566999 0658799 30 Q*S 575/60/3 098865399 05067099 40 R*S 575/60/3 05067399 05069399 50 S*S 575/60/3 0509899 05069599 60 T*S 575/60/3 05069099 05069699 75 U*S 575/60/3 05070499 N/A N/A= Not Available. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 63

Section F- Supply Air Section Belt Guards: Code 49= A, C, D, F 4 40 Air Foil Double Width (AFDW) OR Forward Curved Fans (FCLP, FCMP) Ref. Part Part Fan Size No. Description Number 33 36 40 40 Grille Assembly 055606004 Grille Assembly 055606005 Grille Assembly 055606006 4 Belt Guard Assembly 05560604 Belt Guard Assembly 05560605 Belt Guard Assembly 05560606 Air Foil Single Width (AFSW) with Side Discharge (Code 40= H*), Main Control Box (Code 08= S, F) The main control box is mounted in this section on RDE units (the Supply Air Section is mounted directly to the condenser section). Air Foil Single Width (AFSW) with Side Discharge (Code 40= S*), No Control Box (Code 08= P, D, Y) RPE units (Main Control Box is mounted in the Discharge Plenum Section K). 8 8 80 Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= G*), Main Control Box (Code 08= S, F) The main control box is mounted in this section on RDE units (the Supply Air Section is mounted directly to the Condenser section). 83 8 80 Air Foil Single Width (AFSW) with Bottom Discharge (Code 40= B*), No Control Box (Code 08= P, D, Y) RPE units (Main Control Box is mounted in the Discharge Plenum Section K). 83 8 80 Ref. Part Part Fan Size No. Description Number 44 49 80 Grille Assy 05659 Grille Assy 05659 8 Grille Assy 05659 Grille Assy 05659 8 Grille Assy 056593 83 Grille Assy 056594 8 80 8 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 64

Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP 5 (Code OR Code 3= J**) Diagrams Inverters may be located in a separate section (Code 4=,, 4), OR the Supply Air Section (Code 4= 3, 5, 6, 7, 8, 9). The Inverter and Bypass components are the same regardless of the installation location, although the sheet metal components differ. The diagrams shown below apply to either a Return Air OR Supply Air Inverter (both may be installed if Code 4= 5, 7). Even if Code 4= 8, 9 where only a Return Air Fan Inverter is called for the Inverter and Bypass controls are still normally installed in the Supply Air Section. MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) 40 50 Supply Air OR Return Air Fan Inverter with Bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) 70 75 78 73 7 74 MMP & Contactor Link Detail 76 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 65

Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP 5 (Code OR Code 3= J**) Components Motor HP 5 Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 50 Gasket 05594007 70 MMP30, 40 Motor Control 3000435 3000436 3000438 7 LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor 30004395 M40B, I 300043340 34993330 73 Alarm- Short Circuit 3000498 74 Alarm/Aux. Contact 34993390 75 Line Shield 34993300 76 Cover- Contactor 3499380 3499380 34993803 78 Link Module 3499390 34993903 30004308 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 66

Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP 7.5-5 (Code OR Code 3= K**, L**, M**, N**, P**) Diagrams MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) 40 50 Supply Air OR Return Air Fan Inverter w/ Bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) 70 75 70 73 78 78 7 73 74 76 7 77 77 MMP & Contactor Link Detail MMP p/n 34993409 70 79 MMP & Contactor Link Detail MMP p/n 3499340** 80 70 73 78 7 76 MMP & Contactor Link Detail MMP p/n 34993405,06,07,08 77 80 79 7 77 MMP & Contactor Link Detail MMP p/n 349938606 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 67

Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP 7.5-5 (Code OR Code 3= K**, L**, M**, N**, P**) Components Motor Horsepower 7.5 0 5 0 5 Ref. Sch. Part Part No. Sym. Description Number 40 AFD0,0 Inverter- see Inverter section 50 Gasket 05594007 70 MMP30,40 Motor Control 3000436 3499340 3000438 3000439 3000430 34993405 34993406 300043300 3000438 34993409 349938606 7 LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor 30004395 M40B, I 300043340 34993330 34993340 34993350 34993360 73 Alarm- Short Circuit 3000498 74 Alarm/Aux. Contact 34993390 75 Line Shield 34993300 76 Cover- Contactor 3499380 3499380 34993803 34993804 34993805 77 Aux. Contact Block 349933804 78 Link Module 3499390 34993903 30004308 34993906 34993907 79 Aux. Contact 34993870 80 Lug 34993880 6 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 68

Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP 30-75 (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Diagrams MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) 40 50 Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) 70 75 70 73 78 78 7 73 74 76 7 77 77 MMP & Contactor Link Detail MMP p/n 3000438, 09 70 79 MMP & Contactor Link Detail MMP p/n 3499340** 80 70 73 78 7 76 MMP & Contactor Link Detail MMP p/n 300043300 77 80 79 7 77 MMP & Contactor Link Detail MMP p/n 349938606, 07 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 69

Section F- Supply Air Section Inverter Bypass Control Box /06 & Earlier Motor HP 30-75 (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Components Motor Horsepower 30 40 50 60 75 Ref. Sch. Part Part No. Sym. Description Number 40 AFD0,0 Inverter- see Inverter section Also requires 3 field supplied ring terminals. 50 Gasket 05594007 70 MMP30 Motor Control 300043300 MMP40 3000438 34993409 349938606 349938607 7 LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor 34993350 M40B, I 34993350 34993360 34993360 34993370 73 Alarm- Short Circuit 3000498 76 Cover- Contactor 34993805 77 Aux. Contact Block 349933804 78 Link Module 34993907 79 Aux. Contact 34993870 80 Lug 34993880 6 6 3 3 6 6 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 70

Section F- Supply Air Section Inverter Bypass Control Box /07 thru 5/3 Motor HP 5 (Code OR Code 3= J**) MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) 40 50 Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) 70 Motor HP 5 73 74 7 MMP & Contactor Link Detail 75 Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 50 Gasket 05594007 70 MMP30, 40 Motor Control 349934049 349934050 34993405 7 LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor 349933 M40B, I 3499333 73 Contact- Auxiliary 3499339 Contact- Auxiliary 3499338 74 Link 349939 75 Spacer 34990650 Side Mounted, NO/ NC. Until 0/07. Front Mounted, NO OR NC. 0/07 & Later. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Section F- Supply Air Section Inverter Bypass Control Box /07 thru 5/3 Motor HP 7.5-5 (Code OR Code 3= K**, L**, M**, N**, P**) Diagrams MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) 40 50 Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) 70 77 70 76 70 73 73 77 74 75 7 MMP & Contactor Link Detail MMP p/n 3499340** 7 MMP & Contactor Link Detail MMP p/n 34993448, 34993449 7 MMP & Contactor Link Detail MMP p/n 349938606 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Section F- Supply Air Section Inverter Bypass Control Box /07 thru 5/3 Motor HP 7.5-5 (Code OR Code 3= K**, L**, M**, N**, P**) Components Motor Horsepower 7.5 0 5 0 5 Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 50 Gasket 05594007 70 MMP30, 40 Motor Control 349934050 34993405 34993405 349934053 349934054 349934055 34993447 34993448 34993449 349938606 7 LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor 349933 M40B, I 349933 3499333 3499333 3499333 3499335 3499335 34993353 3499336 73 Contact- Auxiliary 3499338 74 Link 349939 75 Spacer 34990650 76 Interlock- Trip 34993870 77 Lug Kit (3 per kit) 34993880 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 73

Section F- Supply Air Section Inverter Bypass Control Box /07 thru 5/3 Motor HP 30-75 (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Diagrams MMP30 (Supply) MMP40 (Return) 70 7 LR0 (Supply) LR0 (Return) 40 50 Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 3, 5, 8) (Two boxes installed if Code 4= 5) 7 Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) 70 70 73 73 74 7 75 MMP & Contactor Link Detail MMP p/n 349934055 77 70 76 77 7 MMP & Contactor Link Detail MMP p/n 34993447, 48, 49 70 76 77 7 7 MMP & Contactor Link Detail MMP p/n 349938606 MMP & Contactor Link Detail MMP p/n 349938607 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 74

Section F- Supply Air Section Inverter Bypass Control Box /07 thru 5/3 Motor HP 30-75 (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Components Motor Horsepower 30 40 50 60 75 Ref. Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see page after Inverters Also requires 3 field supplied ring terminals. 50 Gasket 05594007 70 MMP30 Motor Control 349934055 MMP40 34993447 34993448 34993449 349938606 349938607 7 LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor 3499333 M40B, I 3499335 3499335 34993353 3499336 3499337 3499337 73 Contact- Auxiliary 349933804 Contact- Auxiliary 3499338 74 Link 349939 75 Spacer 34990650 76 Interlock- Trip 34993870 77 Lug Kit (3 per kit) 34993880 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 75

Section F- Supply Air Section Inverter Bypass Control Box 6/3 & Later Motor HP 5 (Code = J** OR Code 3= J**) 40 50 70 MMP30 (Supply) MMP40 (Return) 7 7 LR0 (Supply) LR0 (Return) Bypass Controls Detail M30B/M30I (Supply) M40B/M40I (Return) Supply Air or Return Air Fan Inverter w/ Bypass Control Box shown. (Code 4= 3, 5, 8) Two boxes installed if Code 4= 5 Phase Barrier 70A Front Mtd. Aux. Contact MMP 70 Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 70B 70B Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) 40 40 Supply Air or Return Air Fan Inverter without Bypass. (Code 4= 6, 7, 9) Link 70C 7 7A Spacer Contactor MMP30/40 & M30/40 Link Detail 5 HP Motors- 08/ Link 70C 7 Contactor MMP30/40 & M30/40 Link Detail 5 HP Motors- 460/ Motor HP 5 Ref Sch. Part Part No. Sym. Description Number 40 VFD0, 0 Inverter- see Inverter section 50 Gasket 05594007 70 MMP30, 40 Motor Protector 93549 93543009 70A Phase Barrier 9354550 70B Aux. Contact 9354380 70C Link 9354600 7 LR0, 0 Line Reactor- see page after Inverters 7 M30B, I Contactor 935906 M40B, I 9353905 9353906 93539304 7A Spacer 9354580 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 76

Section F- Supply Air Section Inverter Bypass Control Box 6/3 & Later Motor HP 7.5-5 (Code OR Code 3= K**, L**, M**, N**, P**) Diagrams 40 Supply Air or Return Air Fan Inverter without Bypass. (Code 4= 7, 9) 40 50 MMP30 (Supply) 70 LR0 (Supply) 7 MMP40 (Return) 70 LR0 (Return) 7 40 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code4= 5 7 7 M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 Phase Barrier Front Mtd. Aux. Contact 70A MMP 70 70B 70B Link 70C 7 Link 70C 7A Spacer Contactor 7 Contactor MMP30/40 & M30/40 Link Detail 7.5 HP Motors- Front Mtd. Aux. Contact 70B Link 70C 7 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 08/ 5, 0 HP Motors- 0 HP Motors- 5 HP Motors- 460/ MMP30/40 & M30/40 Link Detail 7.5 HP Motors- 08/30/ 0, 5 HP Motors- Phase Barrier 70A Front Mtd. Aux. Contact 70B Link 70C 7 MMP 70 Contactor MMP30/40 & M30/40 Link Detail 0, 5 HP Motors- 08/ RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 77

Section F- Supply Air Section Inverter Bypass Control Box 6/3 & Later Motor HP 7.5-5 (Code OR Code 3= K**, L**, M**, N**, P**) Components Motor Horsepower 7.5 0 5 0 5 Ref Sch. Part Part No. Sym. Description Number 40 AFD0, 0 Inverter- see Inverter section 50 Gasket 05594007 70 MMP30,40 Motor Protector 935493 93543008 93543009 9354300 935430 935430 9354330 93543303 93543304 93543305 93543306 93543403 93543404 70A Phase Barrier 9354550 9354730 70B Contact- Auxiliary 9354380 935460 70C Link 9354590 9354600 9354740 9354750 7 LR0, 0 Line Reactor- see page after Inverters 7 M30B, I M40B, I Contactor 9A 9353906 A 935905 6A 935906 5A 93539304 3A 9353950 50A 9353950 65A 9353960 80A 9353960 7A Spacer 9354580 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 78

Section F- Supply Air Section Inverter Bypass Control Box 6/3 & Later Motor HP 30-75 (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Diagrams MMP30 (Supply) MMP40 (Return) 40 Supply Air or Return Air Fan Inverter without Bypass. (Code 4= 7, 9) 40 50 70 LR0 (Supply) 7 70 LR0 (Return) 7 40 Supply Air and Return Air Fan Inverter without Bypass. (Code 4= 7) Supply Air or Return Air Fan Inverter w/bypass Control Box. (Code 4= 5, 8) Two boxes installed if Code4= 5 7 7 M30B/M30I (Supply) M40B/M40I (Return) Bypass Controls Detail Front Mtd. Aux. Contact 70B MMP 70 Phase Barrier 70A Front Mtd. Aux. Contact 70B MMP 70 Link 70C Link 70C 7 7 Contactor Contactor MMP30/40 & M30/40 Link Detail 30 HP Motors- 460/ 40 HP Motors- Contactors 7 MMP30/40 & M30/40 Link Detail 30 HP Motors- 08/ 40 HP Motors- 50, 60 HP Motors- 460/ 75 HP Motors- Overload 78 Interlock 79 MMP30/40 & M30/40 Link Detail 40, 50, 60 HP Motors- 08/ 75 HP Motors- 08/30/ RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 79

Section F- Supply Air Section Inverter Bypass Control Box 6/3 & Later Motor HP 30-75 (Code = Q**, R**, S**, T** OR Code 3= Q**, R**, S**, T**, U**) Components Motor Horsepower 30 40 50 60 75 Ref Sch. Part Part No. Sym. Description Number 40 AFD0,0 Inverter- see next page 50 Gasket 05594007 70 MMP30 Motor Protector MMP40 70-90A 93543405 55-75A 93543404 45-63A 93543403 36-50A 9354340 8-40A 93543305-3A 93543304 70A Phase Barrier 9354730 70B Contact- Auxiliary 935460 70C Link 9354750 9354740 7 LR0,0 Line Reactor- see page after Inverters 7 M30B, I Contactor 5A 935990 M40B, I Contactor 85A 9359803 50A 935980 5A 935980 95A 93539603 80A 9353960 65A 9353960 50A 9353950 40A 9353950 78 OL30 Overload 50-50A 0994880 OL40 Overload 50-00A 9354970 80-00A 93548608 79 Mechanical Interlink 0994890 Mechanical Interlink 935860 N/S CB30,40 Circuit Breaker 5A 93550303 Circuit Breaker 50A 9355030 N/S= Not Shown on Diagram. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 80

Section F- Supply Air Section Inverters AFD0 (Return) AFD0 (Supply) 40 40 Supply Air and Return Air Fan Inverter without Bypass (Code 4= 7) Supply Air or Return Air Fan Inverter without Bypass (Code 4= 6, 7, 9) AFD0/AFD0 Ref. No. 40 Code 5= R: Model VTAC9 08/ Motor Horsepower 5 7.5 0 5 0 5 30 40 50 60 75 Part Number 09886468 09886454 09886469 09886455 09886470 09886456 09886457 09886458 09886459 09886460 0988646 0988646 09886463 09886464 Note that 60 & 75 HP motors are not available in 08/ (Code 09=, 9). 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8

Section F- Supply Air Section Inverters, Continued AFD0/AFD0 Ref. No. 40 Code 5= A: Model ACH550 08/ Motor Horsepower 5 7.5 0 5 0 5 30 40 50 60 75 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ Part Number 04605 04600 04607 04606 046003 04608 04607 046004 04609 04608 046005 046030 04609 046006 04603 04600 046007 04603 0460 046008 046033 0460 046009 046034 04603 04600 046035 0460 046036 0460 The replacement Keypad Display is p/n 30004094. Note that 60 & 75 HP motors are not available in 08/ (Code 09=, 9). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8

Section F- Supply Air Section Inverters, Continued AFD0/AFD0 Ref. No. 40 Code 5= G: Model 3500 Motor Horsepower 5 7.5 0 5 0 5 Part Number 09865696 09865696 098656903 098656943 09865697 09865697 098656904 098656944 09865698 09865698 098656905 098656945 09865699 09865699 098656906 098656946 09865690 098656930 098656907 098656947 0986569 09865693 098656908 098656948 Motor Horsepower 30 40 50 60 75 Part Number 0986569 09865693 098656909 098656949 09865693 098656933 09865690 098656953 098656940 0986569 09865695 0986569 098656954 09865693 Note that 60 & 75 HP motors are not available in 08/ (Code 09=, 9). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 83

AFD0/AFD0 Ref. No. 40 Code 5= S, Q: MD, MD3, MD6 Section F- Supply Air Section Inverters, Continued Motor Horsepower 5 7.5 0 5 0 5 30 40 50 60 5 75 5 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ 08/ Part Number 93475809 9347585 93456304,4 9347580 9347586 93456305,4 934758 9347587 93456306,4 934758 9347588 93456307,4 9347583 9347589 93456308,4 9347584 93475830 349956647 3 9347585 9347583 349956648 3 9347586 9347583 349956649 3 34995667 3 93475883 349956650 3 93475884 3 34995665 3 93475885 3 34995665 3 Units built late 00 & Earlier shipped with ATV VFDs. All ATV drives have been replaced with ATV drives as listed above. These new drives are drop in replacements with the exception of the Remote Keypad and Communication Cards. The ATV Remote Keypad is p/n 34995880. The ATV Lonworks communication card is p/n 3499703. The ATV Remote Keypad is p/n 349958805 and the Remote Keypad Mounting kit is p/n 349958803. The ATV Lonworks communication card is p/n 934860. All other ATV communication cards are integral to the VFD and are not available separately. Note that 60 & 75 HP motors are not available in 08/ (Code 09=, 9). MD3 Remote Keypad p/n is 34995880. 3 MD6 Remote Keypad p/n is 349958805 plus Mount p/n 349958803. 4 For units with an MD3 Inverter and Motor under 5 HP a Line Reactor will be installed regardless of whether one is specified in Code 7 (see nomenclature page). See one page after next for Line Reactor part numbers. 5 Note that 60 & 75 HP motors are not available in 08/ (Code 09=, 9). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 84

AFD0/AFD0 Ref. No. 40 Code 5= B: MD4, MD5 08/ Section F- Supply Air Section Inverters, Continued Motor Horsepower 5 7.5 0 5 0 5 30 40 50 60 75 08/ 08/ 08/ 08/ 08/ 08/ 08/ Part Number 93555 93550 935537 93556 935503 935538 93557 935504 935539 93558 935505 9355330 935539 935506 935533 935530 935507 935533 93553 935508 9355333 93553 9355309 9355334 935533 935530 9355335 93553 9355336 93553 9355337 The replacement VFD Keypad Display is p/n 30004094. Note that 60 & 75 HP motors are not available in 08/ (Code =, 9). 08/ 08/ 08/ RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 85

Section F- Supply Air Section Line Reactors / Motor Horsepower 5 7.5 0 5 0 5 30 40 50 60 75 / / / / / / / / / / Part Number 0733358 07333503 34996499 0733359 07333504 34996493 0733350 07333505 34996497 073335 07333506 349964930 07333534 07333507 34996493 073335 07333508 34996496 073335 07333509 349964954 0733353 07333509 349964955 07333535 349964956 0733350 07333557 07333536 07333558 Line Reactors are optional for all voltages and motor sizes except for MD3 Inverters (Code 5= S, Q ) - 0 HP. These will always have a Line Reactor installed regardless of Code 7. These are 5% impedance Line Reactors. Some units may have had 3% impedance Line Reactors installed. The 5% is to be used in place of the 3% Reactors. If replacing a 3% impedance Line Reactor, due to dimensional differences, minor field modifications may be required for proper installation. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 86

Section F- Supply Air Section Section Mounted Controls PC7, HL, LT0, S0, REC0, UV Lights 0 5 9 PC7- Proof of Airflow Pressure Control Ref. Part Part Qty. No. Description Number 5 Bracket, 9 PC7 Pressure Control 0 Pneumatic Fitting In 6/ the design of PC7 was changed. Units equipped with the old style PC7 require Retrofit Kit 9043 for proper installation as old and new parts are NOT interchangeable. The Switch only is p/n 905489, the Pneumatic Fitting is p/n 9044, and the Support Bracket is p/n 9090. 66 67 HL- Gas Heat Hi Limit Switch Code 04= A Ref. Part Part Qty. No. Description Number 66 Support 05837940 67 T-stat- HL Hi Limit 04793880 84 85 86 87 88 89 LT0- Supply Fan Light/S0- Supply Fan Light Switch/REC0- Supply Fan Receptacle Code 49= B, E, F Ref. Part Part Qty. No. Description Number 84 Light Fixture 049500 85 Bulb- LT0 0654940 86 Junction Box 0654990 87 Junction Box Cover 0654900 88 Light Switch- S0 065490 89 Receptacle- REC0 03087000 98 UV Lights Code 7= C thru C8 AND Y thru Y8 99 Ref. Part Part Qty. No. Description Number 98 Light Fixture- 8 Bulb 0548400 Light Fixture- 4 Bulb 054840 Light Fixture- 36 Bulb 054840 99 Bulb/Lamp, UV- 8 0548450 Bulb/Lamp, UV- 4 0548460 Bulb/Lamp, UV- 36 0548470 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 87

Section F- Supply Air Section Section Mounted Controls MAT, EFT, SAT, DAT, OAT, SD 5 66 Entering Fan Temperature Sensor- EFT Ref. Part Part Qty. No. Description Number 5 EF Temp. Sensor MicroTech II 060004705 MicroTech III 934460 66 Support Bracket 0557340 8 Discharge Air Temperature Sensor- DAT Ref. Part Part Qty. No. Description Number 8 DA Temp. Sensor MicroTech II 060004705 MicroTech III 934460 7 Outdoor Air Temperature Sensor- OAT Ref. Part Part Qty. No. Description Number 7 OA Temp. Sensor MicroTech II 060004705 MicroTech III 934460 5 50 Smoke Detector- SD Ref. Part Part Qty. No. Description Number 50 Smoke Detector- SD 0988730 5 Sensing Tube 0988790 For Standard Discharge applications. For other options, contact Daikin Applied with model and serial number information so that the correct part can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 88

Section F- Supply Air Section Section Mounted Controls SCB- Split Junction Box, TB5, TB7, TB8, PB0, PB9, PB0, PB9 Code 05= F TB8 TB7 TB5 PB 9 PB 0 PB 9 PB 0 Typical Split Junction Box Location Across- The- Line Start (Code 0= AL) Motor HP - 5 30 40, 50 60-75 Sch. Part Part Sym. Description Number Terminal Blocks TB5 Terminal Block- SCB 059984 TB7 Terminal Block- SCB 0599830 TB8 Terminal Block- SCB 059984 PB0 Power Block- Supply Fan 95A, 600V, 3P 03037707 75A, 600V, 3P 0303770 PB9 Power Block- Supply Fan 95A, 600V, 3P 03037707 PB0 Power Block- Return Fan 95A, 600V, 3P 03037707 PB9 Power Block- Return Fan 95A, 600V, 3P 03037707 If Code 0= PW AND Code 05= F, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 89

Section G- Blow-Thru Heat Section for RPE Units Notes & Section Mounted Controls Primary Codes that pertain: 04, 34 Additional Codes that pertain: 06, 07, 08, 09,, 3 This section is divided into four subsections:. Blank Compartment;. HW/Steam Heat; 3. Electric Heat; and 4. Natural Gas Heat. Code 04 determines what type of heat, if any, the unit employs, and Code 34 defines the Heat Section s characteristics. If Code 04= Y, AND Code 34= YYYYYY there is no section. See the Unit Model Number- Complete section at the beginning of this form for specific Heat Section coding. If Code 04= Y AND Code 34= BBBBBB, then there is a 48 Blank Spacer Section installed. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the RPE Blow-Thru Heat Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Code 07 is the Gas Heat Burner Approval Code and affects many of the parts in the Gas Heat Section depending on whether the unit is UL approved (USA) or ETL approved (Canada). Code 08 determines which generation of controls are installed which determines which Electric Heat Controls are used. Code 09 determines the Unit Voltage, which will have an effect on the Electric Heaters and their Controls. Code determines the Control type and will affect the Gas Heat Actuator Motor. Code 3 is the Supply Fan size which affects the Heat Section s Diffusers. Section G pertains to the RPE, but not the RDE. Notes Section Mounted Controls 84 85 86 87 88 89 LT- BT Heat Section Light/S- BT Heat Section Light Switch/REC- BT Heat Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture 049500 85 Bulb- LT 0654940 86 Junction Box 0654990 87 Junction Box Cover 0654900 88 Light Switch- S 065490 89 Receptacle- REC 03087000 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 90

Section G- Blow-Thru Heat Section for RPE Units Option : Blank Compartment Code 34= BBBBBB AND Code 04= Y Diffuser Factory Mounted Diffuser Field Mounted Diffuser (Split Unit) Ref. Part Part Qty. No. Description Number Diffuser Code 3= 33** 055988003 Code 3= 36** 055988004 Code 3= 40** 055988005 The drawing above left shows a Diffuser factory mounted on a unit split at the condenser (Code 05= C), or not split (Code 05=Y). When a unit is split at the Supply Fan (Section F) and Heat Section (Section G) the Diffuser is packaged for field mounting as shown on the drawing on the right. The part numbers are the same in either case. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 9

Section G- Blow-Thru Heat Section for RPE Units Option : Hot Water & Steam Heat Coils, Mixing Valves, & Actuator VM Code 34= W***, W***, OR S***, S***, S3***, S4*** Coil Location Mixing Valve Detail Air Flow 3 65 64 63 Ref. Sch. Part Code Coil Coil Part Qty. No. Sym. Description 34= Type Height Number Hot Water Heat Coil- Bottom W*** 5WH090H 4 056053065 Hot Water Heat Coil- Bottom W*** 5WS090C 4 056053066 3 Hot Water Heat Coil- Top W*** 5WH090H 39 056053045 Hot Water Heat Coil- Top W*** 5WS090C 39 056053046 Valve/Actuator /0 & Earlier 63 Valve, 3 Way- Hot Water Heat.5 W**E3* ALL ALL 047936505.50 W**F3* ALL ALL 04793650.00 W**G3* ALL ALL 04793650.50 W**H3* ALL ALL 047936506 3.00 W**J3* ALL ALL 047936503 64 Linkage-.5 thru.00 Valve *****E ALL ALL 0497640 Linkage-.50, 3.00 Valve *****E ALL ALL 04976403 65 VM Actuator, 0V *****E ALL ALL 059999804 Valve/Actuator / & Later 63 Valve, 3 Way w/ Actuator- HW.5 W**E3* ALL ALL 366703.50 W**F3* ALL ALL 366704.00 W**G3* ALL ALL 366705.50 W**H3* ALL ALL 366706 3.00 W**J3* ALL ALL 366707 65 VM Actuator only, 4V *****E ALL ALL 34960 For Steam Heat Coils and Components (Code 30= S*****) contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. Hot Water Heat 3.00 valve has a flange gasket p/n: 0336000. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 9

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Heaters, Hi Limit Cutouts, Diffusers 300 Air Flow 7 7A 400 Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout Only 300 Heater Assy- Top 80 E080 80 0496906 049695 Heater Assy- Top 80 E080 80 049694 0496933 Heater Assy- Top 80 E080 80 N/A 049694 Heater Assy- Top 00 E00 00 0496905 049694 Heater Assy- Top 00 E00 00 049693 049693 Heater Assy- Top 00 E00 00 N/A 049694 Heater Assy- Top 0 E0 0 0496904 049693 Heater Assy- Top 0 E0 0 04969 049693 Heater Assy- Top 0 E0 0 N/A 0496940 Heater Assy- Top 60 E60 60 0496903 04969 Heater Assy- Top 60 E60 60 04969 0496930 Heater Assy- Top 60 E60 60 N/A 0496939 Heater Assy- Top 00 E00 0 0496904 049693 Heater Assy- Top 00 E00 0 04969 049693 Heater Assy- Top 00 E00 0 N/A 0496940 Heater Assy- Top 40 E40 0 0496904 049693 Heater Assy- Top 40 E40 0 04969 049693 Heater Assy- Top 40 E40 0 N/A 0496940 Heater Assy- Top 80 E80 60 0496903 04969 Heater Assy- Top 80 E80 60 04969 0496930 Heater Assy- Top 80 E80 60 N/A 0496939 Heater Assy- Top 30 E30 60 0496903 04969 Heater Assy- Top 30 E30 60 04969 0496930 Heater Assy- Top 30 E30 60 N/A 0496939 N/A= Not Applicable. Units ETL/MEA USA approval (Code 07= EY) or no approval (Code 07= YY). Heater Assy. includes Hi Limit auto and manual Reset Switches. Units ETL Canada approval (Code 07= CY). Heater Assy. includes Hi Limit auto Reset Switches. 08/ RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 93

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Heaters, Hi Limit Cutouts, Diffusers, Continued Hi Limit Cutout Unit with with Voltage Auto and Auto Ref. Sch. Part Total Code Heater Manual Cutout No. Sym. Description KW 34= KW Cutout Only 400 Blank Assy- Bottom 80-60 E/080-60 0559360 0559360 Heater Assy- Bottom 00 E00 80 0496906 049695 Heater Assy- Bottom 00 E00 80 049694 0496933 Heater Assy- Bottom 00 E00 80 N/A 049694 Heater Assy- Bottom 40 E40 0 0496904 049693 Heater Assy- Bottom 40 E40 0 04969 049693 Heater Assy- Bottom 40 E40 0 N/A 0496940 Heater Assy- Bottom 80 E80 0 0496904 049693 Heater Assy- Bottom 80 E80 0 04969 049693 Heater Assy- Bottom 80 E80 0 N/A 0496940 Heater Assy- Bottom 30 E30 60 0496903 04969 Heater Assy- Bottom 30 E30 60 04969 0496930 Heater Assy- Bottom 30 E30 60 N/A 0496939 7 HL- 0 Hi Limit- Manual Cutout All All All 0654960 N/A 7A HL3-50 Hi Limit- Auto Cutout All All All 0658450 0658450 Diffuser All All All 05565840 05565840 N/A= Not Applicable. Units ETL/MEA USA approval (Code 07= EY) or no approval (Code 07= YY). Heater Assy. includes Hi Limit auto and manual Reset Switches. Units ETL Canada approval (Code 07= CY). Heater Assy. includes Hi Limit auto Reset Switches. 08/ RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 94

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 5/3 & Earlier Disconnect Switch DS3 FB33 FB3 FB3 M33 M3 M3 FB33 FB3 FB36 FB3 FB35 FB33 FB3 FB3 FB44 FB34 M33 M3 M36 M3 M35 M33 M3 M3 M44 M34 FB34 H S 3 FB34 H S 3 FB43 FB4 FB4 H S 3 M34 08/ 0KW- 0KW T B M34 460/ 0KW- 60KW T B M43 M4 M4 460/ 00KW- 30KW T B PB3 PB3 PB3 DS3 or PB3 DS3 or PB3 DS3 or PB3 Sch. Part Disconnect Switch Components Sym. Description Amps Switch Handle Shaft Ground Lug DS3 Disconnect Switch 00 Amp 3499355 34993553 34996 34993800 Disconnect Switch 50 Amp 3499356 349935533 34996 34993800 Disconnect Switch 50 Amp 3499356 349935533 34996 34993800 Disconnect Switch 400 Amp 34993535 3499356 349963 34993800 Disconnect Switch 600 Amp 9343805 4 3, 4 3499643 4 34993800 Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS3 size. Includes mechanism (except 600A switch, see footnote #3). 3 Handle only p/n 349960; Mechanism only p/n 9345500; Shaft only p/n 34996403. 4 Note that the original Disconnect Switch is obsolete. If replacing an original Disconnect Switch, due to dimensional differences, minor field modifications may be required for proper installation. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 95

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 5/3 & Earlier 0-0KW Components Heater KW= 0 40 60 80 00 0 Sch. Part Part Sym. Description Number PB3 Power Block 03037777 Power Block 03037785 PB3 Power Block- DS3 used w/00a, 50A DS3 03037777 used w/50a DS3 03037783 used w/400a DS3 03037785 used w/600a DS3 030377 3 - Cover- PB3 Power Block 3 349938345 HS3 Switch 033696300 TB Terminal Block 3499306 M3 Contactor 349933 Contactor 349933 M3 Contactor 349933 Contactor 349933 M33 Contactor 349933 Contactor 349933 M34 Contactor 349933 Contactor 349933 M35 Contactor 349933 M36 Contactor 349933 Part number is for one section. The number of sections used is determined by the options installed. Not used when PB3 power block connection is present. 3 Cover- PB3 Power Block is used ONLY when 600A DS3 p/n 030377 is supplied. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 96

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 5/3 & Earlier 0-0KW Components, Continued Heater KW= 0 40 60 80 00 0 Sch. Part Part Sym. Description Number FB3 Fuse Block 037809 Fuse Block 037805 Fuse Block 0378030 FB3 Fuse Block 037809 Fuse Block 037805 Fuse Block 0378030 FB33 Fuse Block 037809 Fuse Block 037805 FB34 Fuse Block 037809 Fuse Block 037805 FB35 Fuse Block 037809 FB36 Fuse Block 037809 F3 Fuse- FB3 0586054 3 3 3 3 3 3 3 3 3 3 Fuse- FB3 058605 3 Fuse- FB3 058605 3 Fuse- FB3 05860409 3 3 3 Fuse- FB3 05860408 3 3 3 Fuse- FB3 058604 3 Fuse- FB3 058604 3 Fuse- FB3 0586044 3 3 Fuse- FB3 0586043 3 3 F3 Fuse- FB3 0586054 3 3 3 3 3 3 3 3 Fuse- FB3 058605 3 Fuse- FB3 058605 3 Fuse- FB3 05860409 3 3 3 Fuse- FB3 05860408 3 3 3 Fuse- FB3 058604 3 Fuse- FB3 058604 3 Fuse- FB3 0586044 3 Fuse- FB3 0586043 3 F33 Fuse- FB33 058605 3 Fuse- FB33 058605 3 Fuse- FB33 0586054 3 3 3 3 3 3 Fuse- FB33 05860409 3 3 3 Fuse- FB33 05860408 3 3 3 F34 Fuse- FB34 058605 3 Fuse- FB34 058605 3 Fuse- FB34 0586054 3 3 3 3 3 3 Fuse- FB34 05860409 3 3 3 Fuse- FB34 05860408 3 3 3 F35 Fuse- FB35 0586054 3 3 3 3 F36 Fuse- FB36 0586054 3 3 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 97

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 5/3 & Earlier 60-30KW Components Heater KW= 60 00 40 80 30 Sch. Part Part Sym. Description Number PB3 Power Block 03037785 PB3 Power Block used w/00a, 50A DS3 03037777 used w/50a DS3 03037783 used w/400a DS3 03037785 used w/600a DS3 030377 3 - Cover- PB3 Power Block 3 349938345 HS3 Switch 033696300 TB Terminal Block 3499306 M3 Contactor 349933 M3 Contactor 349933 M33 Contactor 349933 Contactor 34993 M34 Contactor 349933 Contactor 34993 M4 Contactor 349933 Contactor 349933 M4 Contactor 349933 Contactor 349933 M43 Contactor 349933 Contactor 349933 M44 Contactor 349933 Contactor 349933 Part number is for one section. The number of sections used is determined by the options installed. Not used when PB3 power block connection is present. 3 Cover- PB3 Power Block is used ONLY when 600A DS3 p/n 030377 is supplied. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 98

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 5/3 & Earlier 60-30KW Components, Continued Heater KW= 60 00 40 80 30 Sch. Part Part Sym. Description Number FB3 Fuse Block 0378030 FB3 Fuse Block 0378030 FB33 Fuse Block 0378030 Fuse Block 037805 FB34 Fuse Block 0378030 Fuse Block 037805 FB4 Fuse Block 0378030 Fuse Block 037805 FB4 Fuse Block 0378030 Fuse Block 037805 FB43 Fuse Block 0378030 Fuse Block 037805 FB44 Fuse Block 0378030 Fuse Block 037805 F3 Fuse- FB3 0586044 3 3 3 3 3 Fuse- FB3 0586043 3 3 3 3 3 F3 Fuse- FB3 0586044 3 3 3 3 3 Fuse- FB3 0586043 3 3 3 3 3 F33 Fuse- FB33 0586044 3 3 3 Fuse- FB33 0586043 3 3 3 Fuse- FB33 05860409 3 3 Fuse- FB33 05860408 3 3 F34 Fuse- FB34 0586044 3 3 3 Fuse- FB34 0586043 3 3 3 Fuse- FB34 05860409 3 3 Fuse- FB34 05860408 3 3 F4 Fuse- FB4 05860409 3 3 3 Fuse- FB4 05860408 3 3 3 Fuse- FB4 0586044 3 Fuse- FB4 0586043 3 F4 Fuse- FB4 05860409 3 3 3 Fuse- FB4 05860408 3 3 3 Fuse- FB4 0586044 3 Fuse- FB4 0586043 3 F43 Fuse- FB43 05860409 3 Fuse- FB43 05860408 3 Fuse- FB43 0586044 3 3 3 Fuse- FB43 0586043 3 3 3 F44 Fuse- FB44 05860409 3 Fuse- FB44 05860408 3 Fuse- FB44 0586044 3 3 3 Fuse- FB44 0586043 3 3 3 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 99

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 6/3 & Later Disconnect Switch DS3 FB33 FB37 FB3 FB36 FB3 FB35 FB33 FB3 FB3 FB33 FB3 FB3 M33 M37 M3 M36 M3 M35 FB34 FB38 H S 3 M33 M3 M3 FB34 H S 3 M33 FB43 M3 FB4 M3 FB4 H S 3 T B M34 T B M43 M4 M4 T B M34 M38 PB3 PB3 PB3 DS3 or PB3 08/ 0KW- 60KW DS3 or PB3 460/ 0KW- 60KW DS3 or PB3 460/ 00KW- 40KW DS3- Disconnect Switch Sch. Part Disconnect Switch Component Sym. Description Switch Mechanism Handle Shaft Lugs DS3 Disconnect Switch- 00A 93444703 N/A 9340 9359640 N/A Disconnect Switch- 50A 935850 9355080 9340 9359640 9355330 4 Disconnect Switch- 50A 935560 935500 9359570 30004993 3 9355380 4 Disconnect Switch- 400A 935570 935500 9359570 30004993 3 9355400 4 Disconnect Switch- 600A 935580 935500 9359570 30004993 3 935540 4 Disconnects are sized according to various unit specifications. Check installed Switch to verify the correct DS3 size, or contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. This shaft is 4.5 OAL and is designed to be cut to length in the field. 3 This shaft is 7. (83mm) OAL and is designed to be cut to length in the field. For a 9.69 (500mm) OAL use p/n 30004099. 4 Three Lugs are included with each p/n. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 00

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 6/3 & Later 0-0KW Components Heater KW= 0 40 60 80 00 0 Sch. Part Part Sym. Description Number PB3 Power Block 75A 03037777 Power Block 40A 03037785 PB3 Power Block 3 used w/00a, 50A DS3 03037777 used w/50a DS3 03037783 used w/400a DS3 03037785 used w/600a DS3 030377 4 DS3 Disconnect Switch HS3 Switch 033696300 TB Terminal Block 34993064 M3 Contactor 40A 935960 Contactor A 9359005 M3 Contactor 40A 935960 Contactor A 9359005 M33 Contactor 40A 935960 Contactor A 9359005 M34 Contactor 40A 935960 Contactor A 9359005 M35 Contactor 40A 935960 M36 Contactor 40A 935960 Part number is for one section. The number of sections used is determined by the options installed. See the chart on the previous page. 3 Not used when PB3 power block connection is present. 4 Cover- PB3 used with 600A DS3 is p/n 349938345. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 0

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 6/3 & Later 0-0KW Components, Continued Heater KW= 0 40 60 80 00 0 Sch. Part Part Sym. Description Number FB3 Fuse Block 037809 Fuse Block 037805 Fuse Block 0378030 FB3 Fuse Block 037809 Fuse Block 037805 Fuse Block 0378030 FB33 Fuse Block 037809 Fuse Block 037805 FB34 Fuse Block 037809 Fuse Block 037805 FB35 Fuse Block 037809 FB36 Fuse Block 037809 F3 Fuse- FB3 0586054 3 3 3 3 3 3 3 3 3 3 Fuse- FB3 058605 3 Fuse- FB3 058605 3 Fuse- FB3 05860409 3 3 3 Fuse- FB3 05860408 3 3 3 Fuse- FB3 058604 3 Fuse- FB3 058604 3 Fuse- FB3 0586044 3 3 Fuse- FB3 0586043 3 3 F3 Fuse- FB3 0586054 3 3 3 3 3 3 3 3 Fuse- FB3 058605 3 Fuse- FB3 058605 3 Fuse- FB3 05860409 3 3 3 Fuse- FB3 05860408 3 3 3 Fuse- FB3 058604 3 Fuse- FB3 058604 3 Fuse- FB3 0586044 3 Fuse- FB3 0586043 3 F33 Fuse- FB33 058605 3 Fuse- FB33 058605 3 Fuse- FB33 0586054 3 3 3 3 3 3 Fuse- FB33 05860409 3 3 3 Fuse- FB33 05860408 3 3 3 F34 Fuse- FB34 058605 3 Fuse- FB34 058605 3 Fuse- FB34 0586054 3 3 3 3 3 3 Fuse- FB34 05860409 3 3 3 Fuse- FB34 05860408 3 3 3 F35 Fuse- FB35 0586054 3 3 3 3 F36 Fuse- FB36 0586054 3 3 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 0

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 6/3 & Later 60-30KW Components Heater KW= 60 00 40 80 30 Sch. Part Part Sym. Description Number PB3 Power Block 03037785 PB3 Power Block 4 used w/00a, 50A DS3 03037777 used w/50a DS3 03037783 used w/400a DS3 03037785 used w/600a DS3 030377 3 DS3 Disconnect Switch HS3 Switch 033696300 TB Terminal Block 34993064 M3 Contactor 40A 935960 M3 Contactor 40A 935960 M33 Contactor 40A 935960 Contactor A 9359005 M34 Contactor 40A 935960 Contactor A 9359005 M4 Contactor 40A 935960 Contactor A 9359005 M4 Contactor 40A 935960 Contactor A 9359005 M43 Contactor 40A 935960 Contactor A 9359005 M44 Contactor 40A 935960 Contactor A 9359005 FB3 Fuse Block 0378030 FB3 Fuse Block 0378030 FB33 Fuse Block 0378030 Fuse Block 037805 FB34 Fuse Block 0378030 Fuse Block 037805 FB4 Fuse Block 0378030 Fuse Block 037805 FB4 Fuse Block 0378030 Fuse Block 037805 FB43 Fuse Block 0378030 Fuse Block 037805 FB44 Fuse Block 0378030 Fuse Block 037805 Part number is for one section. The number of sections used is determined by the options installed. See chart 3 pages prior. 3 Cover- PB3 used with 600A DS3 is p/n 349938345. 4 Not used when PB3 power block connection is present. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 03

Section G- Blow-Thru Heat Section for RPE Units Option 3: Electric Heat: Code 04= E AND Code 34= E***** Electric Heat Control Box 6/3 & Later 60-30KW Components, Continued Heater KW= 60 00 40 80 30 Sch. Part Part Sym. Description Number F3 Fuse 0586044 3 3 3 3 3 Fuse 0586043 3 3 3 3 3 F3 Fuse 0586044 3 3 3 3 3 Fuse 0586043 3 3 3 3 3 F33 Fuse 0586044 3 3 3 Fuse 0586043 3 3 3 Fuse 05860409 3 3 Fuse 05860408 3 3 F34 Fuse 0586044 3 3 3 Fuse 0586043 3 3 3 Fuse 05860409 3 3 Fuse 05860408 3 3 F4 Fuse 05860409 3 3 3 Fuse 05860408 3 3 3 Fuse 0586044 3 Fuse 0586043 3 F4 Fuse 05860409 3 3 3 Fuse 05860408 3 3 3 Fuse 0586044 3 Fuse 0586043 3 F43 Fuse 05860409 3 Fuse 05860408 3 Fuse 0586044 3 3 3 Fuse 0586043 3 3 3 F44 Fuse 05860409 3 Fuse 05860408 3 Fuse 0586044 3 3 3 Fuse 0586043 3 3 3 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 04

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Heat Exchangers & Vestibules 500, 640, 650, 790, 800, 000, 00, 400MBH Code 34= 050***, 064***, 065***, 079***, 080***, 00***, 0**, 40*** 3 Burner 4 Burner Control Box 5 Gas Train 6 Ref. Part 500/640 650/790 800/000 00/400 Qty. No. Description MBH MBH MBH MBH 3 Heat Exch.- Aluminized Sec. C34= ***A** Heat Exch. Kit- S.S. Sec. C34= ***S** 09839 09835 098353 098354 Vestibule- Top Panel 05563636 05563636 05563636 05563636 Vestibule- Side Panel 0556363 05563633 05563634 05563635 N/S Turbulator 0583870 0583870 0583870 0583870 3 N/S= Not shown on diagram. Aluminized Secondary Heat Exchangers are no longer available. Use the comparable Stainless Steel Secondary Kit p/n instead. Kit includes the Heat Exchanger, Flue Front Cover, Flue Back Cover, Inspection Door, and Inspection Door Gasket. 3 Quantity varies depending upon the size of the Heat Exchanger. For 500/640 MBH order 9 pc.; for 650/790 MBH order pc.; for 800/000 MBH order 5 pc.; for 00/400 MBH order pc. Note that the required Turbulators are NOT included in the Heat Exchanger Kits. 4 Parts detail follows this section. 5 Parts detail follows Burner section. 6 Parts detail follows Burner Control Box section. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 05

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Heat Exchangers & Vestibules 500, 000MBH Code 34= 50***, 00*** 3 Burner 4 Burner Control Box 5 Gas Train 6 Ref. Part 500/000 Qty. No. Description MBH 3 Heat Exchanger- Aluminized Secondary C34= ***A** Heat Exchanger Kit- Stainless Steel Secondary C34= ***S** 098355 N/S Turbulator 0583870 3 7 N/S= Not shown on diagram. Aluminized Secondary Heat Exchangers are no longer available. Use the comparable Stainless Steel Secondary Kit p/n instead. Kit includes the Heat Exchanger, Flue Front Cover, Flue Back Cover, Inspection Door, and Inspection Door Gasket. 3 Note that the required Turbulators are NOT included in the Heat Exchanger Kit. 4 Parts detail follows this section. 5 Parts detail follows Burner section. 6 Parts detail follows Burner Control Box section. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 06

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Diagrams Code 34= ****E*, ****R*, ****S* Burner Control Box 5 5 0 49 3 09 9 500-000 MBH Burners 47 06 30 0 3 6 4 4 7 6 0 04 07 08 05 03 7 8 Pilot Valve / Pressure Regulator Assy. Detail Housing Detail:00-000 MBH Burners 0 49 60 6 50 5 6 4 4 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 07

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Components Code 34= ****E*, ****R*, ****S* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL 0 Burner Housing 500-000 MBH Furnace 0593630 0593630 00-000 MBH Furnace 06667370 06667370 03 Scroll 500-000 MBH Furnace 03574070 03574070 00-000 MBH Furnace 03574090 03574090 04 Wheel-.5 bore, CCW 500-000 MBH Furnace 034860 034860 00-500 MBH Furnace 03449005 03449005 000 MBH Furnace 03449004 03449004 05 Motor 500-000 MBH Furnace 0344900 0344900 00-500 MBH Furnace 0348600 0348600 000 MBH Furnace 0348400 0348400 06 Gun Assembly 500 MBH Furnace 03488000 03488000 640, 650 MBH Furnace 03488000 03488000 790, 800 MBH Furnace 034880003 034880003 000 MBH Furnace 034880004 034880004 00 MBH Furnace 035700 035700 400 MBH Furnace 035700 035700 500 MBH Furnace 0357003 0357003 000 MBH Furnace 03635700 03635700 07 Inlet Funnel 500-000 MBH Furnace 0347430 0347430 00-000 MBH Furnace 0347430 0347430 08 Fan Guard 03474800 03474800 09 Blast Tube 500-650 MBH Furnace 0340703 0340703 790-000 MBH Furnace 0340707 0340707 00, 400 MBH Furnace 0340706 0340706 500, 000 MBH Furnace 0356470 0356470 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 08

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Components, Continued Code 34= ****E*, ****R*, ****S* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL 0 Pilot Mixer 500-000 MBH Furnace 0365640 0365640 00-000 MBH Furnace 0365640 0365640 Pilot Assembly 03509600 03509600 Damper Assembly 500-000 MBH Furnace 035750 0487940 00-000 MBH Furnace 035750 0487940 3 Blast Tube Gasket 500-000 MBH Furnace 0340000 0340000 00, 400 MBH Furnace 0340900 0340900 500, 000 MBH Furnace 0340900 0340900 4 Right Side Damper 500 MBH Furnace 05859430 05859430 640 MBH Furnace 0585950 0585950 650-000 MBH Furnace 05859450 05859450 00 MBH Furnace 05936630 05936630 400 MBH Furnace 0593660 0593660 500, 000 MBH Furnace 05936550 05936550 5 Left Side Damper 500, 640 MBH Furnace 05859500 05859500 650-000 MBH Furnace 05859440 05859440 00 MBH Furnace 05936650 05936650 400 MBH Furnace 05936640 05936640 500, 000 MBH Furnace 0593650 0593650 6 Slide Damper 500 MBH Furnace 058594805 05859485 640 MBH Furnace 058594806 05859486 650 MBH Furnace 058594807 05859487 790 MBH Furnace 058594808 05859488 800 MBH Furnace 058594809 05859489 000 MBH Furnace 05859480 05859480 00 MBH Furnace 05859483 05859483 400 MBH Furnace 058594837 058594837 500 MBH Furnace 058594843 058594843 000 MBH Furnace 058594849 058594849 7 Blower Gasket 03509500 03509500 8 Burner Cover 500-000 MBH Furnace 0339700 0339700 00-000 MBH Furnace 0339730 0339730 9 Ignition Assembly 500-000 MBH Furnace 00-000 MBH Furnace 0 Glass Cover 036557000 036557000 Contact Daikin Applied with model and serial number information so that the correct part can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 09

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Components, Continued Code 34= ****E*, ****R*, ****S* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL Glass Cover Support 036009600 036009600 Orifice 500 MBH Furnace 0585990 0585990 640 MBH Furnace 0585990 0585990 650 MBH Furnace 05859903 05859903 790 MBH Furnace 05859904 05859904 800 MBH Furnace 05859904 05859904 000 MBH Furnace 0585990 0585990 00 MBH Furnace 05936460 05936460 400 MBH Furnace 05936460 05936460 500 MBH Furnace 059364603 059364603 3 Clip 03499400 03499400 4 Flange Bearing 0345000 0345000 5 Air Switch Tube 500-000 MBH Furnace 034080 034080 00-000 MBH Furnace 034070 034070 6 Pilot Burner Tube 500-000 MBH Furnace 0363600 0363600 00, 400 MBH Furnace 0363600 0363600 500, 000 MBH Furnace 03659900 03659900 7 Compression Fitting 034097500 034097500 30 Pilot Tube 034060 034060 47 Torsion Spring not used 03758600 49 Burner Box Baffle 500-000 MBH Furnace 05859790 05859790 00-000 MBH Furnace 05936580 05936580 50 Damper, Slide- Top 00 MBH Furnace 058594830 not used 400 MBH Furnace 058594836 not used 500 MBH Furnace 05859484 not used 000 MBH Furnace 058594848 not used 60 Valve- Pressure Regulator 034077600 034077600 6 Valve- Solenoid 034488400 034488400 N/S Flame Rod 036557700 036557700 N/S Ignition Electrode Assy. 3000390 3000390 N/S= Not shown on diagram. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 0

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Diagrams Code 34= ****H*, ****T*, ****U* 38 4 0 09 9 358 06 3 95 6 0 358 8 0 05 300 30 7 38 375 34 35 45 08 03 3 3 33 04 07 30 44 Detail: Orifice, Control Rod, Control Arm, Linkage, Plate 97 99 0 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Components Code 34= ****H*, ****T*, ****U* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL 0 Burner Housing 500-000 MBH Furnace 0598603 0598603 00-000 MBH Furnace 0598633 0598633 03 Scroll 500 thru 800 MBH Furnace 096434806 096434806 000-000 MBH Furnace 0598636 0598636 04 Wheel-.5 bore, CCW 500-800 MBH Furnace 034860 034860 000-500 MBH Furnace 03449005 03449005 000 MBH Furnace 03449004 03449004 05 Motor-.5 HP, 5/60/ 500-800 MBH Furnace 0344900 0344900 000-500 MBH Furnace 0348600 0348600 000 MBH Furnace 0348400 0348400 06 Gun Assembly 500 MBH Furnace 09644805 09644805 640, 650 MBH Furnace 09644806 09644806 790, 800 MBH Furnace 09644808 09644808 000 MBH Furnace 0964480 0964480 00 MBH Furnace 096448 096448 400 MBH Furnace 096448 096448 500 MBH Furnace 0964483 0964483 000 MBH Furnace 0964484 0964484 07 Inlet Funnel 500-800 MBH Furnace 0347430 0347430 000-000 MBH Furnace 0347430 0347430 08 Fan Guard 03474800 03474800 09 Blast Tube 500, 640 MBH Furnace 0340703 0340707 650-000 MBH Furnace 0340707 0340707 00, 4000 MBH Furnace 0340706 0340706 500, 000 MBH Furnace 0356470 0356470 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Components, Continued Code 34= ****H*, ****T*, ****U* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL 0 Orifice Assembly 500 MBH Furnace 09644705 0964475 640 MBH Furnace 09644706 0964476 650 MBH Furnace 09644707 0964477 790, 800 MBH Furnace 09644708 0964478 000 MBH Furnace 0964470 09644730 00 MBH Furnace 096447 0964473 400 MBH Furnace 096447 0964473 500 MBH Furnace 096447 09644733 000 MBH Furnace 0964474 09644734 3 Gasket- Blast Tube 500-000 MBH Furnace 0340000 0340000 00-000 MBH Furnace 0340900 0340900 4 Air Box Assy 500-000 MBH Furnace 05986 05986 00-000 MBH Furnace 059864 059864 6 Plate- Actuator Scale 05964500 05964500 7 Gasket- Blower 03509500 03509500 8 Panel- Burner Box Cover 500-000 MBH Furnace 05938850 05938850 00-000 MBH Furnace 05964940 05964940 9 Ignition Wire Assy 500-000 MBH Furnace 00-000 MBH Furnace 0 Glass Cover- Burner 036557000 036557000 Support- Glass Cover 036009600 036009600 44 Grommet- Flat 0600770 0600770 45 Box- Conduit (500-800 MBH only) 036558800 036558800 95 Motor- Actuator 04770 04770 97 Control Arm 500-000 MBH Furnace 059864 059864 00-000 MBH Furnace 0598644 0598644 99 Control Rod 500-000 MBH Furnace 059860 059860 00-000 MBH Furnace 05965050 05965050 300 Crank Arm 500-000 MBH Furnace 0596450 0596450 00-000 MBH Furnace 0346300 0346300 Contact Daikin Applied with model and serial number information so that the correct part can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Components, Continued Code 34= ****H*, ****T*, ****U* Burner Approval Code Qty. Ref. Part C07= EU, EF, EI C07= CC, CD No. Description UL/ETL ETL 30 Extension- Crank Arm 059860 059860 38 Bushing- Control Rod 0598630 0598630 30 Linkage 0964490 0964490 3 Plate- Adjustable 500 MBH Furnace 06008640 096490 640 MBH Furnace 0964770 0964780 650 MBH Furnace 0964630 0964630 790 MBH Furnace 0600970 0600970 800 MBH Furnace 0600970 096470 000 MBH Furnace 0600940 06009730 00 MBH Furnace 096450 096450 400 MBH Furnace Until 7/06 09640 09640 400 MBH Furnace 7/06 & Later 096400 096400 500 MBH Furnace 096400 096400 000 MBH Furnace 0964030 0964030 3 Plate- Profile 500 MBH Furnace 0600860 0600860 640 MBH Furnace 0964790 0964790 650 MBH Furnace 0964530 0964800 790 MBH Furnace 0964650 0964650 800 MBH Furnace 06009690 06009700 000 MBH Furnace 0600960 0600970 00 MBH Furnace 05964880 096440 400 MBH Furnace 09640 096430 500 MBH Furnace 0964980 0964990 000 MBH Furnace 0964970 0964000 33 Plate- Slide Damper 500 MBH Furnace 06008630 06008630 640, 650 MBH Furnace 0964760 0964760 790, 800, 000 MBH Furnace 0600950 0600950 00, 400, 500 MBH Furnace 0596490 0596490 000 MBH Furnace 0964040 0964050 34 Box- Air 500-000 MBH Furnace 060090 060090 00-000 Furnace 060090 060090 35 Gasket- Air Box 500-000 MBH Furnace 0600930 0600930 00-000 Furnace 096470 096470 38 Grommet 00049800 00049800 358 Bearing- Sleeve 04676000 04676000 375 Grommet 500-000 MBH Furnace 059988700 059988700 00-000 Furnace 059988800 059988800 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Controls: MicroTech II Code = *D, *S AND Code 34= ****E*, ****R*, ****S* Diagrams 5 4 3 4 30 7 39 6 63 FSG Detail 6 3 34 9 5 Gas Control Box RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Controls: MicroTech II Code = *D, *S AND Code 34= ****E*, ****R*, ****S* Components Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 00/50 30 400-000 GV Pressure Reg. Assy. 06530300 06530300 03974000 Valve Only 034077600 034077600 034077600 Manual Cock Valve 034077300 034077300 not used Solenoid Valve not used not used 034488400 Support 05938870 05938870 not used 4 Flame Safeguard Subbase 07330070 07330070 07330070 5 FSG Flame Safeguard Until 4/07 07330080 07330080 07330080 Flame Safeguard 4/07 & Later 073300803 073300803 073300803 6 Amplifier 07330090 07330090 07330090 7 Flame Safeguard T.D. 90 Sec. Modulating Burner/UL Units 0733000 0733000 0733000 Flame Safeguard T.D. 30 Sec. Modulating Burner/ETL 0733000 0733000 0733000 9 S3 Toggle Switch- 4PST 033536700 033536700 033536700 30 IT Ignition Transformer 03448600 03448600 03448600 3 Air Switch- Gas Burner 033003800 033003800 033003800 3 FLC Fan Limit Control Until 9/08 0733370 0733370 0733370 Fan Limit Control 9/08 & Later 9343703 9343703 9343703 34 TB Terminal Block- 4 Pole 059984 059984 059984 Jumper, Terminal Block 0035400 0035400 0035400 39 Fitting 0679770 0679770 0679770 4 Bushing 004600 004600 004600 6 R0 Relay Until /0 0609403 0609403 0609403 N/S R0A Relay /0 & Later 349934764 349934764 349934764 N/S Relay Socket 34996470 34996470 34996470 63 R3 Pilot Relay Until 5/08 044465500 044465500 044465500 R3 Pilot Relay 6/08 thru /0 09643000 09643000 09643000 N/S R3A Pilot Relay /0 & Later, ETL only 349934764 349934764 349934764 N/S Mounting Adapter 34996470 34996470 34996470 N/S R3B Pilot Relay /0 & Later 9345470 9345470 9345470 N/S Relay Socket 9345480 9345480 9345480 N/S= Not shown on diagram. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Controls: MicroTech III Code = *E, *F, *W AND Code 34= ****E*, ****R*, ****S* 64 6 63 6 3 30 3 34 5 4 9 Gas Control Box 6 5 7 FSG Detail Gas Valve Detail Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 500-000 00-000 GV Pressure Reg. Assy 03974000 03974000 Valve Only 034077600 034077600 Solenoid Valve 034488400 034488400 4 Flame Safeguard Subbase 07330070 07330070 5 FSG Flame Safeguard 073300803 073300803 6 Amplifier 07330090 07330090 7 Flame Safeguard T.D. 90 Sec. UL Units 0733000 0733000 Flame Safeguard T.D. 30 Sec. ETL Units 0733000 0733000 9 S3 Toggle Switch- 4PST: S3 033536700 033536700 30 IT Ignition Transformer 03448600 03448600 3 AS Air Switch- Gas Burner 033003800 033003800 3 FLC Fan Limit Control 9343703 9343703 34 TB Terminal Block 34993064 34993064 9 Terminal Block End Stop 34993084 34993084 Terminal Block End Plate 34993074 34993074 Jumper Terminal 34993094 34993094 6 R0A Relay- High Amp DPDT/0V 349934764 349934764 6 R3A Relay- High Amp DPDT/0V 349934764 349934764 63 R3B Relay- Low Amp DPDT/0V 934434 934434 64 M9 Contactor- Motor DPDT/0V not used 349934764 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: MicroTech II Code = *D, *S AND Code 34= ****H*, ****T*, ****U* Diagrams 4 30 34 66 65 39 3 5 4 6 63 6 7 64 3 FSG Detail 3 9 33 4 6 66 65 00-000 MBH Panel Detail 34 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: MicroTech II Code = *D, *S AND Code 34= ****H*, ****T*, ****U* Components Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 500-000 00-000 Support 05938870 05938870 3 Support 05938860 05964970 4 Subbase- Flame Safeguard 07330070 07330070 5 FSG Control- Flame Safeguard 07330080 07330080 6 Amplifier 07330090 07330090 7 Time Delay- Flame Safeguard 07330003 07330003 9 S3 Switch- Toggle 033536700 033536700 30 IT Transformer- Ignition 03448600 03448600 3 AS Switch- Air 033003800 033003800 3 FLC Control- Fan Limit until 9/08 0733370 0733370 Control- Fan Limit 9/08 & later 9343703 9343703 33 LS/LS Switch- Limit 05997530 05997530 34 TB Terminal Block 059984 059984 Jumper, Terminal Block 0035400 0035400 39 Fitting 0679770 0679770 4 Bushing 004600 004600 4 Bushing 0497590 0497590 6 R0 Relay, 4V/DPDT 0650800 0650800 N/S R0A Relay 0V /0 & Later 349934764 349934764 N/S Mounting Adapter 34996470 34996470 N/S R0B Relay 0V /0 & Later 9345470 9345470 Relay Socket 9345480 9345480 6 M9 Contactor- Motor not used 07400700 63 R3 Relay- 0V/DPDT 3/0 & Earlier 09643000 09643000 N/S R3B Relay- 0VSPST 4/0 & Later 9345470 9345470 Relay Socket 9345480 9345480 64 R Relay- 0V/DPDT 3/0 & Earlier 09643000 09643000 64 R Relay- 0V/DPDT 4/0 & Later 9345470 9345470 Relay Socket 9345480 9345480 65 R Relay- 0VSPST 3/0 & Earlier 07400700 07400700 65 R Relay- 0VSPST 4/0 & Later 349964764 349964764 N/S Mounting Adapter 34996470 34996470 66 TD0 Relay- Time Delay 0.0 Sec. 08006 08006 N/S= Not shown on diagram. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 9

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Controls: MicroTech III Code = *E, *F, *W AND Code 34= ****H*, ****T*, ****U* 66 65 6 63 64 30 3 6 3 34 5 4 33 6 9 7 5 FSG Detail Ref. Sch. Part Furnace MBH Qty. No. Sym. Description 500-000 00-000 4 Subbase- Flame Safeguard 07330070 07330070 5 FSG Control- Flame Safeguard 07330080 07330080 6 Amplifier 07330090 07330090 7 Time Delay- Flame Safeguard 0733000 0733000 9 S3 Switch- Toggle 033536700 033536700 30 IT Transformer- Ignition 03448600 03448600 3 AS Switch- Air 033003800 033003800 3 FLC Control- Fan Limit 9343703 9343703 33 LS, LS Switch- Limit 05997530 05997530 34 TB Terminal 34993064 34993064 Terminal Block End Stop 34993084 34993084 Terminal Block End Plate 34993074 34993074 6 R0A Relay- High Amp DPDT/0V 349934764 349934764 6 R0B Relay- Low Amp DPDT/0V 934434 934434 63 R, Relay- Low Amp DPDT/0V 934434 934434 64 R3A Relay- High Amp DPDT/0V not used 349934764 65 R3B Relay- Low Amp DPDT/0V not used 934434 66 M9 Relay- High Amp DPDT/0V not used 349934764 Quantity varies. Determine quantity required BEFORE ordering, or contact Daikin Applied with model and serial number information so that the correct number of parts can be supplied. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 0

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Gas Train Inlet- Modulating Burner Code 34= ****E*, ****R*, ****S* Units without Pressure Regulator Valve Code 34= ****E* 34 05 05 34 500-500 MBH 000 MBH Ref. Part Part Qty. No. Description Number 05 Shutoff Valve 500-000 MBH 034077300 34 Gas Valve 500 MBH 904486 640-000 MBH 904487 00-500 MBH 904488 000 MBH 904489 8 Units with Pressure Regulator Valve Code 34= ****R*, ****S* 8 8 8 34 05 05 34 05 34 8 05 34 34 05 500, 640, 650 or 800 MBH Furnaces 000 MBH Furnaces 00, 400 MBH Furnaces 500 MBH Furnaces 000 MBH Furnaces Ref. Part Pressure Regulator Qty. No. Description - 3 PSI 5-0 PSI 05 Shutoff Valve 034077300 034077300 8 Pressure Regulator 500 MBH 0366994 0366995 640, 650 MBH 0366993 0366995 790, 800 MBH 036699 0366994 000 MBH 0733870 0366993 00 MBH 07338730 0366993 400 MBH 07338730 073387303 500 MBH 07338730 07338730 000 MBH 073387306 07338730 34 Gas Valve 500 MBH 07338740 07338740 640-500 MBH 073387403 073387403 000 MBH 073387404 073387403 Code 34= ****R*. Code 34= ****S*. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Gas Train Inlet- Hi Turn Down Burner Code 34= ****H*, ****T*, ****U* Units without Pressure Regulator Valve Code 34= ****H* 6 Ref. Part Part Qty. No. Description Number 6 Gas Valve 500 MBH 904486 640-000 MBH 904487 00-500 MBH 904488 000 MBH 904489 Units with Pressure Regulator Valve Code 34= ****T*, ****U* 6 3 Ref. Part Pressure Regulator Qty. No. Description - 3 PSI 5-0 PSI 6 Shutoff Valve 500 MBH 07338740 07338740 640-500 MBH 073387403 073387403 000 MBH 073387404 073387403 3 Pressure Regulator 500 MBH 0366994 0366995 640, 650 MBH 0366993 0366995 790, 800 MBH 036699 0366994 000 MBH 0733870 0366993 00 MBH 0733870 0366993 400 MBH 07338730 073387303 500 MBH 07338730 07338730 000 MBH 073387306 07338730 Code 34= ****T*. Code 34= ****U*. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Modulating Burner Gas Train Controls GV, GV3 Code 34= ****E*, ****R*, ****S* 53 GV 56 48 6 55 GV3 Ref. Part Part Qty. No. Description Number 48 Gas Valve (GV, GV3) 500 MBH 07338780 640-000 MBH 07338780 00-500 MBH 073387803 000 MBH 073387804 53 Pressure Regulator 500 MBH 03407800 640-000 MBH 034077804 00-500 MBH 03407780 000 MBH 034077803 55 Junction Box 0076600 56 Junction Box Cover 0007300 6 Gas Pipe Modulating Burner 500 MBH 05596400 640 MBH 05596408 650, 790 MBH 05596403 800, 000 MBH 0559640 00, 400 MBH 0336400 500 MBH 0560090 000 MBH 056008 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Hi Turn Down Burner Gas Train Controls GV, GV4, GV5, GV6, GV7, GV8 Code 34= ****H*, ****T*, ****U* 500-650 MBH Furnaces 790-000 MBH Furnaces 00 MBH Furnaces 54 GV4 GV5 GV4 GV6 54 GV 54 GV 54 GV GV5 54 54 GV4 400, 500 MBH Furnaces 000 MBH Furnaces 54 GV7 GV 54 GV7 GV8 54 54 54 GV6 54 GV6 54 GV5 54 GV4 GV5 54 GV4 54 54 GV Ref. Part Part Qty. No. Description Number 54 Gas Valve (GV, GV4) 400-650 MBH 073336504 Gas Valve (GV, GV4, GV5) 790-000 MBH 073336504 3 Gas Valve (GV, GV4, GV5, GV6) 00 MBH 073336504 4 Gas Valve (GV, GV4, GV5, GV6, GV7) 400, 500 MBH 073336504 5 Gas Valve (GV, GV4, GV5, GV6, GV7, GV8) 000 MBH 073336504 6 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Gas Train- Outlet 500, 640 MBH Burners 75 Actuator & Linkage (See next page) 650-000 MBH Burners 75 Actuator & Linkage (See next page) 77 77 83 83 Modulating Burners Code 34= ****E*, ****R*, ****S* Ref. Part Part Qty. No. Description Number 75 Pipe w/ Valve Mount 500 MBH 03509800 640-000 MBH 03635500 00, 400 MBH 03509900 500, 000 MBH 03635600 77 Butterfly Valve 500 MBH 034488303 640-400 MBH 034488304 500, 000 MBH 034488305 83 Shutoff Valve 500 MBH 05946880 640-800 MBH 059468803 000 MBH UL 058968804 000 MBH ETL 059468803 00-500 MBH 059468804 000 MBH 059468805 650, 000 MBH Burners 500, 640 MBH Burners 75 75 Hi Turn Down Burners Code 34= ****H*, ****T*, ****U* Ref. Part Part Qty. No. Description Number 75 Gas Valve 500 MBH 904486 640-000 MBH 904487 00-500 MBH 904488 000 MBH 904489 790-500 MBH Burners 75 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat: Code 04= A Gas Train- Modulating Burners w/ VM Actuator (09/08 & Earlier) Code 34= ****E*, ****R*, ****S* Burner Box 95 Butterfly Valve (See previous page) 3 98 97 99 300 30 Ref. Part Furnace MBH Qty. No. Description 500-650 790-000 00, 400 500, 000 95 Actuator Motor 04770 04770 04770 04770 97 Crank Arm 03450600 03450600 03450600 03450600 98 Ball Joint 03450500 03450500 03450500 03450500 99 Linkage Arm 05859840 05859840 0593760 05936870 300 Crank Arm 0346300 0346300 0346300 0346300 30 Air Damper Lever Arm 05936500 0585980 0585980 not used 3 Gas Valve Arm 05859860 05859860 05859860 05859860 For units built 0/08 & Later contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat w/ 30MBH thru 000 MBH Furnace Code 04= A AND Code 34= 050***,064***,065***,079***,080***, 00***, 0***, 40*** Cabinet Doors, Gasketing, Hardware, & Flue Box Mounting 65 650 663 66 669 665 664 668 668 667 673 658 Ref. Part Part Qty. No. Description Number 650 Door Assembly 500, 640 MBH 096845 650, 790 MBH 096844 800, 000 MBH 0968453 00, 400 MBH 0968444 65 Inspection Door Assy. 03409580 658 Back- Flue Box 500, 640 MBH 40339980 650, 790 MBH 4034000 800, 000 MBH 40340040 00, 400 MBH 40340070 66 Angle- Flue Box 500, 640 MBH 40339990 650, 790 MBH 4034000 800, 000 MBH 40340050 00, 400 MBH 40340080 663 Drip Shield 033487300 664 Sleeve Bearing 04738507 3 665 Door Catch 0555060 3 667 Gasket 0559409 668 Gasket 055940 669 Gasket- Inspection Door 0394900 673 Hinge 034005900 Note that individual parts of the Inspection Door Assembly are not available separately. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Section G- Blow-Thru Heat Section for RPE Units Option 4- Gas Heat w/ 500 MBH & 000 MBH Furnace Code 04= A AND Code 34= 50***, 00*** Cabinet Doors, Gasketing, Hardware, & Flue Box Mounting 665 664 65 663 66 650 658 669 667 668 Ref. Part Part No. Description Number Qty. 650 Door Assembly 0968445 65 Inspection Door Assy. 03409580 658 Back- Flue Box 4034000 66 Angle- Flue Box 05594500 663 Drip Shield 033487300 664 Sleeve Bearing 04738507 3 665 Door Catch 0555060 3 667 Gasket 0559409 668 Gasket 055940 669 Gasket- Inspection Door 0394900 Note that individual parts of the Inspection Door Assembly are not available separately. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8

Section H- Blow-Thru Heat Blank Access Section Notes, Access Door Hardware, & Section Mounted Controls Primary Codes that pertain: 34, 38 Additional Codes that pertain: 06 Code 34 determines the Blow-thru Heat Section (Section G). There has to be a Section G in order for there to be a Section H, therefore Code 34 cannot= YYYYYY. Code 38 determines all of the section characteristics. If Code 38= B, F there is a 48 Blow-Thru Blank Section. If Code 38= E there is a 4 Blow-Thru Blank Section. If Code 38= Y, there is no Section. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blow-Thru Heat Blank Access Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. Note that the Access Door Hardware part numbers listed below are the same for ALL RPE and RDE units regardless of the particular section s function or location EXCEPT for the Vestibule/ Access Section. See Section L for Vestibule/Access Section Door hardware. Section H pertains to the RPE, but not the RDE. Notes Access Door Latching Assemblies (All Sections) Ref. Part Part Qty. No. Description Number 0 Access Door Latching Assy., LH 4 0 Access Door Latching Assy., RH 4 N/S Sleeve Bearing 04738507 8 N/S Door Catch 0555060 8 N/S Gasket- Horizontal 0559408 4 N/S Gasket- Vertical 05594 4 N/S= Not Shown on diagram. These Door Latching Assemblies are used on Standard Unit Section Access Doors. When replacing a Latch Assembly, first determine the handing of the door. Door handing is dependent upon the door s location on the unit. For Handing identification, refer to the drawings below. If unable to determine the hand of the door, contact Daikin Applied with model and serial information AND the location of the door. If the unit is split at the Fan and Heat Sections (Code 05= F) use p/n 0559409. 0 0 Door Latching Assy. Left Hand Door Latching Assy. Right Hand RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 9

Section I- Blow-Thru Cooling Section Notes & Section Mounted Controls Primary Codes that pertain: 03, 35, 36 Additional Codes that pertain: 06 Code 03 determines the Cooling Coil size. If Code 03= S there is a small face area Coil (4 section for unit sizes 076 thru 00C, or normally a 48 section for unit size 0C although some units may have a 4 section installed). Small face area Coils are not available on 30 thru 50C unit sizes. If Code 03= L it is a large face area Coil (48 section for unit sizes 076 thru 00C, or 4/48 for unit sizes 0 thru 50C). Code 35 determines if there is a Section I. If Code 35= YYYY, then there is no Section. If the code is CYYY, CYYS then there is a unit Cooling Coil and Drain Pan. An S in the fourth position of this code means the Drain Pan is stainless steel. A Y in the fourth position indicates that the Drain Pan is made of painted galvanized steel. Code 36 determines Cooling Coil characteristics. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Blow-Thru Cooling Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Section I pertains to the RPE, but not the RDE. Notes NOTE: See Section D for all parts used in Section I. Although the section location is different within the unit configuration, the components are identical. Section Mounted Controls 84 85 86 87 88 89 LT6- Blow-Thru Cooling Section Light/S6- Blow-Thru Cooling Light Switch/ REC6- Blow-Thru Cooling Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture 049500 85 Bulb- LT6 0654940 86 Junction Box 0654990 87 Junction Box Cover 0654900 88 Light Switch- S6 065490 89 Receptacle- REC6 03087000 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 30

Section J- Final Filter Section Notes & Section Mounted Controls Primary Codes that pertain: 39 Additional Codes that pertain: 04, 33 (Mid 0 & Later), 34 Code 39 determines all of the Section characteristics. If Code 39= A, B, E, F there is a Final Filter Section with factory supplied Filters. If Code 39= C, D there is a blank/empty compartment. If Code 39= Y, there is no Section. In order for there to be a Section J, Code 34 CANNOT be YYYYYY AND Code 35 MUST be YYYY (no Blow-Thru Coil Section). Codes 04 and 34 determine what type of heat the unit uses. The type of heat influences the filter media and associated parts. Code 33 (Mid 0 & Later) indicates the presence of Magnehelic/Differential Pressure Gauges. See Section B (Filter Section) for Gauge part number and description. Section J pertains to the RPE, but not the RDE. Notes Section Mounted Controls HL3 Gas Hi Limit Control: Code 04= A AND Code 39= A, B, C, D, E, F PC6 Clogged Filter Control: Code 39= A, B, E, F Control HL3 Gas Heat Hi-Limit (Firestat) Clogged Filter Pressure Switch- PC6 387 386 Unit Air Flow 345 Ref. Part Part Qty. No. Description Number 386 Stat Support 05837940 387 Firestat- HL3 047938804 Ref. Part Part Qty. No. Description Number 345 Pressure Ctl.- PC6 06549380 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Section J- Final Filter Section Filters 5 5A 4 4A Flat Filter Rack- Code 39= A, E Ref. Part Code Code Part Qty. No. Description 04= 5 = Number 4 Filter- 95% Eff- Cartridge High Heat 4 A, E A 073380 Filter- 95% Eff- Cartridge Standard 4 S, W A 0658070 4A Gasket- Filter High Heat 4 A, E A 07333704 Gasket- Filter Standard 4 S, W A 076894 5 Filter- 95% Eff- Cartridge 3 High Heat 4 A, E A 073380 4 Filter- 95% Eff- Cartridge 3 Standard 4 S, W A 0658070 4 5A Gasket- Filter High Heat 4 A, E A 0733370 4 Gasket- Filter Standard 4 S, W A 07689 4 If Code 5= E (Intersept) Contact Daikin Applied. Filter size= 4 x 4 x. 3 Filter size= x 4 x. 4 High Heat filters are used on units with Gas or Electric heat. Standard filters are used with Steam, HW Heat. 4 4A Staggered Filter Rack- Code 39= B, F 4 4A Ref. Part Code Code Part Qty. No. Description 04= 5 5 = Number 4 Filter- 95% Eff- Cartridge 6 High Heat 7 A, E B 073380 6 Filter- 95% Eff- Cartridge 6 Standard 7 S, W B 0658070 6 4A Gasket- Filter High Heat 7 A, E B 07333704 6 Gasket- Filter Standard 7 S, W B 076894 6 5 If Code 5= F (Intersept) Contact Daikin Applied. 6 Filter size= 4 x 4 x. 7 High Heat filters are used on units with Gas or Electric heat. Standard filters are used with Steam, HW Heat. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Section K- Discharge Plenum Section for RPE Units Notes Primary Codes that pertain: 08, 40 Additional Codes that pertain: 6,, 6, 34, 35, 36, 38, 39, 4. Code 08 determines the location of the Main Control Box. If Code 08= P, D the Main Control Box is located in the Discharge Plenum Section (Section K). If Code 08= C, V the Main Control Box is located in The Vestibule/Access Section (Section L). If Code 08= H, T the Main Control Box is located in the Heat Section (Section E, G). Code 40 determines the discharge direction. Options include Bottom Discharge (Code BE, BY) OR side discharge (Code LY, RY, SY). If Code 40= BB then the unit has Bottom Discharge with Burglar Bars. If Code 40= BE, the unit has Bottom Discharge with an Isolation Damper and Actuator ACT5. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Discharge Plenum Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. For Standard Door Latching Assemblies, see Section H- Blow-Thru Heat Blank Access Section. Code, Disconnect Switch option, influences Access Door part numbers. Code 6 determines Smoke Detectors. If Code 6=, 3 there is a Supply Air Smoke Detector (SD). For RPE units with heat SD is in Section K. Codes 34, 35, 36, 38, 39, the Blow-thru/Final Filter Section codes, and Code 4, the Standard Service Vestibule code, pertain to some of the final assembly part numbers. Section K pertains to the RPE, but not the RDE. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 33

Section K- Discharge Plenum Section for RPE Units Section Mounted Controls 7 Discharge Air Temperature Sensor- DAT & Outdoor Air Temperature Sensor- OAT Unit Air Flow OAT Ref. Part Part Qty. No. Description Number 7 OA Temp. Sensor MicroTech II 060004705 MicroTech III 934460 8 DA Temp. Sensor MicroTech II 060004705 MicroTech III 934460 8 DAT 5 50 Smoke Detector- SD Ref. Part Part Qty. No. Description Number 50 Smoke Detector 0988730 5 Sensing Tube 0988790 For Standard Discharge applications. For other options, contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 84 85 86 87 88 89 LT5- Discharge Plenum Section Light/ S5- Discharge Plenum Section Light Switch/ REC5- Discharge Plenum Section Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture 049500 85 Bulb- LT5 0654940 86 Junction Box 0654990 87 Junction Box Cover 0654900 88 Light Switch- S5 065490 89 Receptacle- REC5 03087000 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 34

Section K- Discharge Plenum Section for RPE Units Isolation Damper w/ Actuator ACT5 Code 40= BE Diagrams 0/ & Earlier ACT6 Actuator Detail 5 0 3 5 8 0 3 6 4 4 9 7 0/ & Later ACT6 Actuator Detail 5 0 3 5 8 0 8 3 6 4 4 9 7 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 35

Section K- Discharge Plenum Section for RPE Units Isolation Damper w/ Actuator ACT5 Code 40= BE Components Ref. Part Part Qty. No. Description Number Isolation Damper Assy- Motorized / & Earlier 05596 Isolation Damper Assy- Motorized / & Later 40376306 3 Motor Mount Assembly / & Earlier 05590 Motor Mount Assembly / & Later 0559370 4 Blade Assembly- Return, 4 055930 5 5 Angle- Linkage 0559790 3 6 Angle- Blade 0556380 45 7 Shaft- Damper Blade 05563780 30 8 Shaft- Linkage 05553660 9 Bearing, Flange, Nylon 003500 30 0 Actuator- Motorized- SPDT (ACT6), 0V / & Earlier 059999804 Actuator- Motorized- SPDT (ACT6), 4V / & Later 34490 Crank Arm- Damper / & Earlier 037900 Crank Arm- Damper / & Later 403770 Ball Joint 000887000 3 Bearing- Sleeve 04738507 45 4 Gasket, Vinyl 03005985 6 8 Bearing- Sleeve / & Later 04738504 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 36

Section L- Vestibule/Access Section Notes & Section Mounted Controls Codes that pertain: 08, 4, 43 Additional Codes that pertain: 06, 09 Notes Code 08 determines the location of the Main Control Box. If Code 08= V the Main Control Box is located in the Vestibule/Access Section. Inverters for the Condenser Fans (Speedtrol Inverters) are located next to the Main Control Box when Code 08= V. For Main Control Box Components and Speedtrol Inverters see Section N. Code 4, Vestibule Compartment option, is always. The Vestibule/Access Section consists of a 4 Section plus a 48 Access Section which houses the unit s Water Treatment components. Code 43 determines the characteristics of the unit s Water Treatment system and Compressor Conduit type. If Code 43= E*, the unit has no Vestibule OR Sump Heater. If Code 43= S*, the unit has a Sump Heater. If Code 43= V*, the unit has a Vestibule Heater. If Code 43= B*, the unit has both a Sump AND a Vestibule Heater. The second digit of Code 43 defines Water Treatment features and Compressor Conduit type. Refer to the Unit Model Number- Complete section of this form for more detailed information. Code 06 determines the liners and insulation, and will affect the final assembly panels. For sheet metal components that make up the Vestibule/Access Section, contact Daikin Applied to ensure that correct liners, insulation and hardware are ordered. Note that Door Hardware for Section L is DIFFERENT from the rest of the unit. Vestibule/Access Section Door Hardware is listed on the following page. Code 09, unit voltage, affects Transformers, Contactors, Motor Protectors, Pumps, and other electrical components. Section Mounted Controls 84 85 86 87 88 89 LT0- Vestibule/Access Light/S0- Vestibule/ Access Light Switch/REC0- Vestibule/ Access Receptacle Ref. Part Part Qty. No. Description Number 84 Light Fixture 049500 85 Bulb- LT0 0654940 86 Junction Box 0654990 87 Junction Box Cover 0654900 88 Light Switch- S0 065490 89 Receptacle- REC0 03087000 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 37

Section L- Vestibule/Access Section Vestibule/Access Section Door Hardware & Wall Fan 868 879 887 89 3 886 Handle Detail Ref. Part Part Qty. No. Description Number Access Door Latching Assy., RH 4 3 Access Door Latching Assy., LH 4 868 Fan, Wall 0988760 879 Roller Cam 03470 886 Fastener, Non-Locking 05500 887 Fastener, Locking Mechanism 09887540 89 Handle Locking 09887560 Non-Locking (not shown) 09887550 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 38

Section L- Vestibule/Access Section Sump Pump, Vestibule Damper, & Vestibule Heater: Code 43= B*, V* Sump Pump & Vestibule Damper 0 50 5 5 Ref. Part Part Qty. No. Description Number 0 Sump Pump- Unit sizes 076-00C 08/30/ 03070 03080 Sump Pump- Unit sizes 0-50C 08/30/ 03780 03790 N/S Sump Pump Shaft Seal Kit 30004479 50 Damper- Vent 933660 5 Intake Screen 0380 5 Bearing, Flange 04738507 4 N/S= Not Shown on Diagram. Vestibule Heater 4793 Ref. Schematic Part Part Qty. No. Symbol Description Number 4793 HTR66 Heater- Vestibule Code 43= B*, V* 03680 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 39

Section L- Vestibule/Access Section Water Treatment Controls without Water Make-Up 700 705 70 75 640 64 647 643 64 73 7 70 64 7 940 939 59 Ref. Schematic Part Part Qty. No. Symbol Description Number 59 Valve, Water 7/8 ODS 04070 64 ACT64 Actuator- Purge 90753 640 Valve, Water 3/4 FPT 0530 64 Valve, Water 7/8 ODS 04070 64 Valve, Water- Drain 3/4 FPT 04080 643 Valve, Water 3/4 FPT 0530 647 ACT6 Actuator- Sump Fill 90753 700 Water Treatment Pipe Coil- Sump /07 & Earlier 05300 /07 & Later 33590 705 Dolphin T Transformer- Sump /07 & Earlier 0530 /07 & Later 33570 70 Dolphin CTL Conductivity Control /07 & Earlier 0530 /07 & Later 33580 7 Electrical Box 049700 7 Receptacle- GFCI 039003600 73 Cover, Electrical Box 066793800 75 Cyclone Centrifugal Separator 05080 70 Pressure Gauge 0-30 psi 0570 939 Valve, Water /07 & Earlier FPT 5730 /07 & Later 3/4 FPT 0530 940 ACT6 Actuator- Blowdown 90753 The above diagrams show standard component layouts. Not all components are used in every situation. Visually confirm the piping configuration and component placement before ordering or, contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Note that the Make Up Water option was first offered in 009. On 08/0 the original Actuator p/n 0540 was discontinued and replaced with functional replacement p/n 90753. Overall dimensions differ slightly, but function is equivalent. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 40

Section L- Vestibule/Access Section Water Treatment Controls with Water Make-Up 700 647 643 70 705 644 704 75 640 64 70 940 939 59 5 50 64 64 Ref. Schematic Part Part Qty. No. Symbol Description Number 50 Valve, Water 3/4 FPT 0530 5 ACT6 Actuator- Blowdown 90753 59 Valve, Water 7/8 ODS 04070 64 ACT64 Actuator- Purge 90753 640 Valve, Water 3/4 FPT 0530 64 Valve, Water 7/8 ODS 04070 64 Valve, Water- Drain 3/4 FPT 04080 643 Valve, Water 3/4 FPT 0530 644 Water Treatment Pipe Coil- Make Up Water 9007754 647 ACT6 Actuator- Sump Fill 90753 700 Water Treatment Pipe Coil- Sump 33590 704 Dolphin T Transformer- Make Up Water 9007755 705 Dolphin T Transformer- Sump 33570 70 Dolphin CTL Conductivity Control /07 & Earlier 0530 /07 & Later 33580 75 Cyclone Centrifugal Separator 05080 70 Pressure Gauge 0-30 psi 0570 939 Valve, Water 3/4 FPT 0530 940 ACT63 Actuator- Auto System Drain 90753 The above diagrams show standard component layouts. Not all components are used in every situation. Visually confirm the piping configuration and component placement before ordering or, contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified. Note that the Make Up Water option was first offered in 009. On 08/0 the original Actuator p/n 0540 was discontinued and replaced with functional replacement p/n 90753. Overall dimensions differ slightly, but function is equivalent. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Section M- Condenser Section Notes Primary Codes that pertain: 4, 43, 44, 45, 47 Additional Codes that pertain: 09, 0 Code 4 affects Compressor capacity control. This code determines the number of Compressor unloaders specified. Note that replacement compressors are shipped with maximum unloading capability. Code 43 determines the characteristics of the unit s Condenser options and Compressor Conduit type. Refer to the Unit Model Number- Complete section of this form for more detailed information. Code 44 determines the Compressor refrigerant used. Code 44= H indicates R and Code 44= K specifies R407C. Note that ALL Evaporative Condensing units use Semi Hermetic Discus Compressors. Code 45 determines the way the Compressors are mounted. Code 47 determines the Inverter vendor for low ambient operation. Code 47= A means that ABB Inverters were specified. Code 47= G indicates Graham/DanFoss brand Inverters were installed. Code 47= Q shows Schneider Inverters were furnished. Code 47= R shows Reliance brand Inverters were chosen. Code 47= B, S indicates that Daikin Applied brand Inverters were used. Note that ALL Evaporative Condensing units are equipped for low ambient operation (Code 47 CANNOT = Y). Code 09, Unit voltage, & Code 0, Compressor starting options, affect Compressor, Compressor Contactor, and Condenser Motor selection. For Main Control Box components see Section N. For refrigeration components see Section O. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Section M- Condenser Section Sump Water Temp. Sensor SWT, Water Level Switches WL63, WL64, & Sump Heater HTR65 Code 43= B*, S* 0A 0B 6 Ref. Schematic Part Part Qty. No. Symbol Description Number SWT Sensor- Sump Water Temperature MicroTech II (Code = *D, *S) 060004705 MicroTech III (Code = *E, *F, *W) 9344603 0A WL63 Switch- Level 09/08 & Earlier 8660 0/08 & Later 8660 0B WL64 Switch- Level 09/08 & Earlier 8660 0/08 & Later 8660 6 HTR65 Heater- Sump (Code 43= B*, S*) 84840 The Sensor for this Level Switch CANNOT be ordered separately. If the Switch s Sensor fails, the Switch must be replaced. This Switch is normally open (NO) in the dry position. To make it a normally closed (NC) valve, rotate the Switch Assembly 80 degrees to change the Switch logic from NO to NC. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 43

Section M- Condenser Section Fan Deck Assembly- Diagrams Fan Deck Assy. 076-00C Fan Deck Assy. 0-50C 6 34 6 34 7 7 Fan Motor Mounting Detail 37 35 Condenser Fan Arrangement Fan # Fan # Fan #3 Fan # Fan # Fan # Fan # Fan #3 Fan # Fan # RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 44

Section M- Condenser Section Fan Deck Assembly- Components Ref. Part Part Unit Size No. Description Number 076 089 00 0 30 40 50 7 Panel, Fan Shroud /04 & Before 57090 4 4 4 6 6 6 6 /05 & Later 933080 4 4 4 6 6 6 6 6 Guard, Fan 09866830 4 4 4 6 6 6 6 34 Screw, Tapping 046093809 6 6 6 4 4 4 4 35 Motor, Fan 08/30/ 300 4 4 4 6 6 6 6 Motor, Fan 06889 4 4 4 6 6 6 6 37 Prop, Fan 6 8450 4 4 4 6 6 6 6 A different motor was used in units built 005 & Earlier. Motor 300 is the specified replacement for ALL 08- Condenser Fans regardless of build date. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 45

Section M- Condenser Section Condenser Coils A Ref. Part Part Unit Size No. Description Number 076 089 00 0 30 40 50, A Coil, Evaporative Condenser 847690 Coil, Evaporative Condenser 84760 Coil, Evaporative Condenser 847635 Spray Nozzle 84830 4 4 4 4 4 4 4 Contact Daikin Applied with model and serial number information so that the correct coil can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 46

Section M- Condenser Section Compressor Layout Diagrams Two Compressor Layout 076-00C Compressor # 00 00 Compressor # Four Compressor Layout 0-50C Compressor #4 400 #4 Compressor # 00 #3 # # 300 Compressor #3 00 Compressor # RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 47

Section M- Condenser Section Compressors Unit Size 076 089 00 0 30 40 50 Ref. Part Part No. Description Number 4 Compressors 5HP R 0 or unloader 5 30004800 4 0 or unloader 5 3000480 4 5HP R407C 3 0 or unloader 5 3000480 4 0 or unloader 5 3000480 4 08/ 08/ 08/ 08/ 08/ 08/ 30HP R 0- unloaders 5 30004803 0- unloaders 5 300048033 0 or unloader 5 30004805 4 0 or unloader 5 30004807 4 30HP R407C 3 0 or unloader 5 30004803 0 or unloader 30004803 0 or unloader 30004806 4 0 or unloader 30004808 4 35HP R 0- unloaders 5 300048036 4 0- unloaders 5 30004804 4 35HP R407C 3 0- unloaders 5 300048037 4 0- unloaders 5 30004804 4 40HP R 0- unloaders 5 30004805 0- unloaders 5 300048048 0- unloaders 5 300048050 40HP R407C 3 0- unloaders 5 300048053 0- unloaders 5 300048049 0- unloaders 5 30004805 For units (Code 09= 37) contact Daikin Applied so that the correct compressor(s) can be identified. Note that starting early in 0 there was a vendor change in the Compressors. Compressors built 0 and later utilize a CoreSense Controller and related components. Replacement Compressors will NOT come equipped with a Controller; therefore the Controller from the previous Compressor will need to be reused. If the CoreSense Controller needs to be replaced, contact Daikin Applied for more information. Code 44= H. 3 Code 44= K. 4 For unit size 40C: Compressors Ref. # 00 & 00 are 30HP, and Compressors Ref. # 300 & 400 are 35HP. 5 All 4 cylinder compressors 30HP and smaller are equipped with one Unloader and all 30-40HP 6 cylinder Compressors are equipped with two Unloaders. Note that ALL Compressors come with maximum unloading capacity standard. If a replacement Unloader is needed, refer to the following page. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 48

Section M- Condenser Section Compressor Components 4 K J L H M N P G 00 00 300 400 Oil Equalization Detail Unit Size Ref. Part Part No. Description Number 076 089 00 0 30 40 50 G Crankcase Heater Liquid Tite Conduit 05947900 Flex Conduit 05944300 All Conduits 03078400 H High Pressure Control 0473560 J Valve- Unloader 046497300 3 3 3 3 3 3 3 K Gasket- Unloader 046498800 3 3 3 3 3 3 3 L Gasket 0707048 M Low Pressure Control 047356 N Valve- Oil Equalization 04970 P Cap- Oil Equal. Valve 000600 Code 43= D, *F, *J, *L, *N. Code 43= *E, *H, *K, *M, *Y. 3 Quantity of Unloader Valve is as required. There are Gaskets PER Valve. Note that ALL Compressors come with maximum unloading capacity standard. Order replacement parts as needed. 4 For Suction and Discharge Service Valves see Refrigeration Tubing Section (Section O). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 49

Section M- Condenser Section Compressor Mounting Resilient Mount (Code 45= ) 0 4 4 3 0 Ref. Part Comp. Part Qty. No. Description HP Number 4 Channel- Rubber Mount All 05556550 4 0 Spacer Pad- Lower All 04763300 4 Spacer Pad- Upper All 04763400 4 Spacer- Rubber All 0994000 4 0 Screw- Cap, 3/8-6 X All 0488788 8 Nut- Hex, Flanged All 03333304 8 Bolt- Hex 5/8- X.75 All 04049955 4 3 Nut- Hex, 5/8- All 04050000 8 4 Washer- Flat, 5/8 All 0405003 4 Spring Mount (Code 45= ) 9 4 0 Ref. Part Comp. Part Qty. No. Description HP Number 4 Channel- Spring Mount All 05564600 4 9 Spring Isolator Kit 0 0040900 Spring Isolator Kit 5, 30 00403600 Spring Isolator Kit 35 0943900 Spring Isolator Kit 40 03489500 0 Screw- Cap, 3/8-6 X All 0488788 8 Nut- Hex, Flanged All 03333304 8 Kit contains 4 Springs. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 50

Section N- Controls Notes Primary Codes that pertain: 08, 09,,, 3, 4, 5, 7, 8 Additional Codes that pertain: 04, 0,, 3, 34, 40, 47 There have been four generations of Main Control Boxes offered:. The original MicroTech II Control Box (Code 08= P, S AND Code = *D, *S) was used from the start of production in 004 until the end of March, 005. This Control Box had the Main Processor (MCB) mounted in the Control Panel with the Keypad mounted in the Dead Front Door.. The redesigned MicroTech II Control Box (Code 08= V AND Code = *D, *S) was used April, 005 until the end of December, 00. There is a MCB as well as two Compressor Control Boards (CCB, CCB) in the Control Box. In January, 007 a vendor change was made for Contactors, MMPs, Relays, and related components. Form and function are identical, however these components and related accessories are NOT directly interchangeable. 3. The MicroTech III (Code 08= V AND Code = *E, *F, *W) Control Box was introduced in January, 0. The Controller (MCB) changed and the Compressor Control Boards were replaced with Expansion Modules (EXPA- D), however the majority of components are the same as the later MicroTech II design. 4. In May of 03 the entire MicroTech III Control Box underwent a major redesign. This design change not only changed components, but some Contactor, Motor Protector, and Inverter circuiting changed. Note that components and component accessories such as Auxiliaries, Links, etc. are NOT interchangeable with any previous design. Code 08 determines the location of the Main Control Box. If Code 08= V the Main Control Box is located in the Vestibule/Access Section (Section L). If Code 08= P, S, the Main Control Box is located in the Supply Air/Discharge Plenum Section (Section F). Components are the same in both cases. Code 9, unit voltage, affects Transformers, Overloads/MMPs, Contactors, Fuses, etc. Code determines whether the main power connection is a Terminal Block or a through-the-door Disconnect Switch. Code selects the unit s control type (MicroTech version), communication protocol, and whether the unit is set up for Discharge Air, Space Control, or Zone control. Evaporative Condensing units MUST be sold with MicroTech Controls. Code 3 determines the presence of Duct and/or Space Sensors. Codes 4 and 5 determine Supply and Return Air Inverter options. For Inverter part numbers refer to the Supply Air Section (Section F). Code 7 determines whether the unit is equipped with a PVM (Phase Voltage Monitor), Freezestat, UV Lights, Ground Fault Protection, and/or Line Reactors. Code 8 indicates whether a unit has a Remote Keypad Display, Unit Powered Receptacle, and/or a Modem. Codes 04 and 34 determine the heat type, which impacts Transformers and Heating/Cooling Circuit Relays. Codes 0, are Return Air codes that impact several controls options. The presence of an OA hood, the horsepower of the Return Air Motor, etc. have an impact on Contactors, Overloads/MMPs, Fuses, and Duct Sensors. Code 3 determines horsepower of the Supply Air Fan Motor which, like the Return Air Motor, affects Contactors, Fuses, Overloads/MMPs, etc. Code 40 determines if there is an Isolation Damper and associated Relay. Code 47 determines Condenser Fan Inverter selection. Inverters for the Condenser Fans are located next to the Main Control Box. Note that ALL Evaporative Condensing units are set up for Low Ambient operation (Code 47 CANNOT = Y). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Section N- Controls MicroTech II Controls: Code = *D, *S Unit Control Layout Diagram- 3/05 & Earlier Speedtrol Inverter/VFD (AFD/VFD) Main Control Box Electronic Control Panel Condenser Control Box Deadfront Door Keypad Display Power Panel Main Disconnect (DS) Compressor Control Box Control/Switch Panel Oil Pressure Box The above diagram shows a typical Unit Control layout and is to be used for reference only. Specific unit configuration may differ depending upon unit options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Main Control Box Layout Diagram See Power Panel Section The above diagram shows a typical Main Control Box layout and is to be used for reference only. Specific unit components, component quantity, and Control Box configuration may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 53

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Main Control Box Components Sch. Part Part Qty. Sym. Description Number Switches S Toggle Switch- Control: Units with Gas Heat (Code 04= A) 08446400 Toggle Switch- Control: Units w/o Gas Heat (Code 04= E, W, S, Y) 80005045 S4, S5 Toggle Switch- Inverters (Code 4= - 9) 08798400 Connector Bar- Inverter on Supply and Return Air Fan 0335000 S7 Rocker Switch- On/Off 074080 PS3 Pumpdown Switches- Refrigeration Circuits 80005045 Fusing F Fuseholder- Control Circuit 08690600 Fuse- Control Circuit 05954700 F3 Fuse Block- Gas Heat Units 037800 Fuse, Gas Heat Units: 500-000 MBH furnaces 05860505 Fuse, Gas Heat Units: 00-000 MBH furnaces 05860507 Receptacle REC Receptacle- GFI 039003600 Receptacle- Std. 5A 0583700 Terminal Blocks TB Terminal Block- 30 Terminals 04330 TB3 Terminal Block- 30 Terminals 0599830 TB4 Terminal Block- 0 Terminals 059980 TB5, 6 Terminal Block, 4 Terminals 059984 TB0 Terminal Block- Terminals: Electric, Gas Heat (Code 04= E, A) 05998 Terminal Block- Terminals: Hot Water, Steam, No Heat (Code 04= W, S,Y) 043 NB, Terminal Block- Neutral Block 037530800 Transformers T, T3 Transformer- Control Circuit 06000460 T9 Transformer- Refrigerant Circuit 06063080 Relays R, Relay- High Pressure Reset 035080 R3, 4 Relay- High Pressure 035080 R0 Relay- Gas, Steam, Hot Water Heat (Code 04= W, S, A) 063000 R4 Relay- Gas Heat 035080 R5 Relay, Gas Heat: Units with Inverters (Code 4= - 9) 035080 R6 Relay- Iso Damper 07330540 R8 Relay- Isolation Damper (Code 40= BE OR Code 9= BE) 063000 R45 Relay- UV Lights 063000 R46,47 Relay- Supply Fan 077896 R48,49 Relay- Exhaust Fan Inverter 077896 R64 Relay- Sump Pump 063000 R67 Relay, Control: units with inverters (Code 4= - 9) 07330540 Relay, Control: units w/o inverters (Code 4= Y) 063000 R68 Relay- Return Fan w/ Inverter or Exhaust Fan 07330540 Relay- Return Fan w/o inverter 063000 R69 Relay- Inverters w/ Bypass (Code 4=,, 3, 4, 5, 8) 035080 TD3, 4 Relay, Time Delay- High Pressure 05670 Not Shown on diagram. Relay Assembly. Consists of: Relay- p/n 060070; Socket Only- p/n 0600690; Clip Only- p/n 0600700. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 54

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Main Control Box Components, Continued Sch. Part Part Qty. Sym. Description Number MicroTech II Controller and Associated Boards MCB Main Control Board 0600060 CCB, Auxiliary Cooling Control Board 060 Fuse, Auxiliary Cooling Control Board 0650 Com Module- Bacnet MSTP (RS-485) (Code = B*) 0600060 Standoff- RS-485 Comm Module 04866707 4 Com Card- Bacnet with Ethernet (Code = E*) 0600060 Com Card- LonMark with Space Control (Code = LS) 06000603 Com Card- LonMark with Discharge Control (Code = LD) 06000604 Standoff- Com Card 04866706 4 Kit- Connector Repair 300036605 PWR Power Supply 5VDC 04960 Serial Port Ribbon Cable 0470 Battery 04975450 EHB Electric Heat Board (Code 04= E) 060 Standoff EHB 04866705 7 Communication Module 0600060 Standoff- Comm Module 04866707 4 Keypad Keypad Assy. (Code 9= R, Y) 06000630 Board- Remote Keypad Interface (Code 9= R) 060 Cable- Keypad 04460 - MicroTech II Remote Keypad Kit 300040364 Transducers and Pressure Controls SPS Static Pressure Transducer- Duct/Building (Code 3=,, 3) 049545007 SPS Static Pressure Transducer- Duct (Code 3= ) 049545007 Static Pressure Transducer- Building (Code 3= 3, 4) 049545006 DHL Duct Hi-Limit Pressure Control 06549380 Pressure Fitting- DHL 04976300 Sensors ZNT Sensor- Zone Temperature w/ Tenant Override 0480 Sensor- Zone Termp. w/ Tenant Override & Remote Setpoint Adjustment, 3 0480 DAT Sensor- Discharge Air Temperature 060004705 ENT Sensor- Entering Air Temperature 060004705 OAT Sensor- Outside Air Temperature 060004705 RAT Sensor- Return Air Temperature 060004705 This Controller must be programmed in order to function correctly. When ordering a replacement, provide the unit model and serial number so the unit specific software code can be loaded before shipment. Not Shown on diagram. 3 SCC Units only- Code = BS, LS, ES, SS. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 55

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Power Panel Diagram The above diagram shows a typical Power Panel layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 56

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Power Panel Components Sch. Part Part Voltage Sym. Description Number Disconnect Switch (Code = A, B, C, D) DS, Disconnect Switch 60A/600V 0344600 Handle Mechanism- 60A Switch 033400 Disconnect Switch 00A/600V 0586060 Handle Mechanism- 00A Switch 0586400 Disconnect Switch 50A/600V 0474404 Handle Mechanism- 50A Switch 03990300 Disconnect Switch 400A/600V- inlet holes 04744 Handle Mechanism- 400A Switch 0586500 Disconnect Switch 400A/40V- inlet holes 0586070 Handle Mechanism- 400A Switch 0586500 Disconnect Switch 400A/600V- inlet hole 0474409 Handle Mechanism- 400A Switch 0586500 Disconnect Switch 400A/40V- inlet hole 0474408 Handle Mechanism- 400A Switch 0586500 Disconnect Switch 600A/600V 0707060 Handle Mechanism- 600A Switch 0839900 Disconnect Switch 800A/600V- inlet holes 030940 Handle Mechanism- 800A Switch 030600 Disconnect Switch 800A/600V- inlet hole 03094 Handle Mechanism- 800A Switch 0306 Disconnect Switch 00A/600V 030950 Handle Mechanism- 00A Switch 030700 The Disconnect Switch used on a given unit is contingent upon unit voltage, Motor horsepower, and other options. Check the part in the unit to size up the replacement, or contact Daikin Applied with the unit model and serial number information so that the correct part(s) can be identified. Note that DS is used only when Code = B, C, D. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 57

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Power Panel Components, Continued 0 Horsepower Motor- Code OR 3= N** Sch. Part Part Voltage Sym. Description Number Contactors M0, 0 Contactor- Supply (M0), Return (M0) Fan Motor Fuse Blocks and Fuses FB0, 0 Fuse Block- Supply (FB0), Return (FB0) Fan Motor Fuse Block- Supply (FB0), Return (FB0) Fan Motor 03780 Fuse- FB0 OR FB0 3 3 3 Fuse- FB0 OR FB0 80A, 600V 0586046 3 Overloads and Heaters OL0, 0 Overload- Supply (OL0), Return (OL0) Fan Motor Overload- Supply (OL0), Return (OL0) Fan Motor Overload Heater- OL0,0 Overload Heater- OL0,0 NOTE: Quantities Listed are PER motor. Contact Daikin Applied with the unit model and serial number information so that the correct part(s) can be identified. Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 58

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Power Panel Components, Continued 40 Horsepower Motor- Code OR 3= R** Sch. Part Part Voltage Sym. Description Number Contactors M0, 0 Contactor- Supply (M0), Return (M0) Fan Motor Contactor- Supply (M0), Return (M0) Fan Motor 0754406 Fuse Blocks and Fuses FB0, 0 Fuse Block- Supply (FB0), Return (FB0) Fan Motor Fuse Block- Supply (FB0), Return (FB0) Fan Motor 03780 Fuse- FB0 OR FB0 3 3 3 Fuse- FB0 OR FB0 80A, 600V 0586046 3 Overloads and Heaters OL0, 0 Overload- Supply (OL0), Return (OL0) Fan Motor Overload- Supply (OL0), Return (OL0) Fan Motor Overload Heater- OL0,0 Overload Heater- OL0,0 NOTE: Quantities Listed are PER motor. Contact Daikin Applied with the unit model and serial number information so that the correct part(s) can be identified. Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 59

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Power Panel Components, Continued 50 Horsepower Motor- Code OR 3= S** Sch. Part Part Voltage Sym. Description Number Contactors M0, 0 Contactor- Supply (M0), Return (M0) Fan Motor Fuse Blocks and Fuses FB0, 0 Fuse Block- Supply (FB0), Return (FB0) Fan Motor Fuse Block- Supply (FB0), Return (FB0) Fan Motor 03780 Fuse- FB0 OR FB0 3 3 3 Fuse- FB0 OR FB0 00A, 600V 0586048 3 Overloads and Heaters OL0, 0 Overload- Supply (OL0), Return (OL0) Fan Motor Overload- Supply (OL0), Return (OL0) Fan Motor Overload Heater- OL0,0 Overload Heater- OL0,0 NOTE: Quantities Listed are PER motor. Contact Daikin Applied with the unit model and serial number information so that the correct part(s) can be identified. Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 60

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Control/Switch Panel Sch. Part Part Qty. Sym. Description Number CS, Switch- Control Stop 80005045 PS, Switch- Pumpdown 80005045 REC Receptacle- GFI 039003600 The above diagram shows a typical Control/Switch Panel layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Condenser Control Box- Diagrams The above diagram shows a typical four Fan Condenser Control Box layout (sizes 076-00C) and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size, and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Condenser Control Box- Components Unit Sizes Sch. Part Part 076-00 0-50 Sym. Description Number Transformer T Transformer- Main Transformer- Main, Gas Heat (Code 04= A) 03853904 Transformer- Main, No Heat (Code 04= Y) 0385393 Fuse Blocks & Fuses FB8 Fuse Block- T Transformer P, 30A 0378003 Fuse- FB8 Fuse Block Fuse- FB8 Fuse Block, Gas Heat (Code 04= A) 05860437 Fuse- FB8 Fuse Block, No Heat (Code 04= Y) 05860433 FB, Fuse Block- Condenser Fan 037800 Fuse- FB, FB 6 6 6 6 6 6 Fuse- FB, FB 5A, 600V 05860405 6 6 FB, 3 Fuse Block- Condenser Fan 037800 Fuse- FB, FB3 6 6 6 6 6 6 Fuse- FB, FB3 5A, 600V 05860405 6 6 FB64 Fuse Block- Water Pump 0378005 Fuse- FB64 5A, 600V 05860405 3 3 3 3 3 3 3 3 FB65 Fuse Block- Sump Heater 0378004 Fuse- FB65 5A, 80V 05860505 3 3 3 3 3 3 3 3 Terminal Block TB Terminal Block- Receptacle 6P, 0A 04306 Phase Voltage Monitor PVM Phase Voltage Monitor 09886040 Overloads OL,, OL, Overload- Condenser Fans 3 4 4 4 4 4 4 4 4 OL3, 3 Overload- Condenser Fans 3 OL64 Overload- Water Pump 3 Heater- Cond. Fan/Water Pump Overload 3 5 5 5 5 7 7 7 7 Contactors M, Contactor- Condenser Fan Motor 0476960 M3, 3 Contactor- Condenser Fan Motor 0476960 M64 Contactor- Water Pump 075440 Phase Voltage Monitor is used when Code 7= *P, *A, *C, *D, *H, *J, *K. Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 3 Note that there have been two different series of Overloads and Overload heaters used during the production run. When replacing an Overload OR the matching Overload Heater it is VITAL to obtain vendor p/n and amperage rating from BOTH parts. When replacing ONLY an Overload Heater, it is VERY IMPORTANT to first obtain vendor information and amperage rating from the existing Overload, Overload Heater, and Motor. It is important to obtain this information to ensure that the correct Overload Heater is selected since Overload Heaters are chosen based upon Motor amperage draw, AND Overload Heaters are NOT interchangeable between series. Also, Overload Heaters DO NOT automatically come with Overloads. OVERLOAD HEATERS MUST BE ORDERED SEPARATELY. Once vendor and amperage information is obtained, contact Daikin Applied for p/ns. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 63

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Compressor Control Box- Diagram The above diagram shows a typical four Compressor Control Box layout (sizes 0-50C) and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 64

Section N- Controls MicroTech II: Code = *D, *S- 3/05 & Earlier Compressor Control Box- Components 08/ Unit Size 076 089 00 0 30 40 50 08/ 08/ 08/ 08/ 08/ 08/ Sch. Part Part Sym. Description Number Fuse Blocks & Fuses FB, Fuse Block- Compressor Fuse Block- Compressor 03780 Fuse Block- Compressor 037800 Fuse- FB OR FB 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Fuse- FB OR FB 80A 0586046 6 6 FB3, 4 Fuse Block- Compressor Fuse Block- Compressor 03780 Fuse Block- Compressor 037800 Fuse- FB OR FB 6 6 6 6 6 6 6 6 6 6 Fuse- FB OR FB 60A 0586044 6 Fuse- FB OR FB 80A 0586046 6 Contactors M, Contactor- Compressor Contactor- Compressor 60A 0754405 Contactor- Compressor 50A 0754404 M3, 4 Contactor- Compressor Contactor- Compressor 50A 0754404 Contactor- Compressor 60A 0754405 There is one component PER compressor. Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 65

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Diagram The above diagram shows a typical four compressor (size 0-50C) Main Control Box layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 66

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller 0600060 Com Card- Bacnet (Code = B*) 0600060 Com Card- Bacnet with Ethernet (Code = E*) 0600060 Com Card- LonMark Space Control (Code = LS) 06000603 Com Card- LonMark Discharge Control (Code = LD) 06000604 Standoff- Com Card 04866706 4 Kit- Connector Repair 300036605 Serial Port Ribbon Cable 0470 Battery 04975450 Grounding Bar 34993690 Keypad Keypad Keypad 06000630 Remote Keypad Interface Board 060 Cable- Interface 34993850 Compressor Controller CCB, Expansion Board- Compressor Controller 060 Fuse- Expansion Board 0650 Standoff- Expansion Board 04866705 4 Comm. Card- Bacnet 0600060 Standoff- Comm. Card 04866707 8 RES Resistor- CCB 06000390 Electric Heat Board EHB Expansion Board- Electric Heat 060 Standoff- Expansion Board 04866705 7 Expansion Board Comm. Card- Bacnet 0600060 Standoff- Comm. Card 04866707 4 Switches- Control HS Switch- Electric Heat Shutdown (Code 04= E) 80005045 PS, Switch- Pumpdown 80005045 CS, Switch- Control 08446400 S Switch- System On/Off Gas Heat Units (Code 04= A) 08446400 Elec.,Steam,HW, No Heat (Code 04= E,S,W,Y) 80005045 S4 Switch- Inverter Bypass On/Off 08798400 S7 Switch- Local On/Auto/Off to Controller 349930 Serial Cables Serial Serial Cable 0470 Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch 06549380 SPS Pressure Transducer- Duct Sensor (Code 3=,, 3) 049545007 SPS Pressure Transducer- Duct Sensor (Code 3= ) 049545007 Pressure Transducer- Space Sensor (Code 3= 3, 4) 049545006 This Controller must be programmed in order to function correctly. When ordering a replacement, provide the unit model and serial number so the unit specific software code can be loaded before shipment. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 67

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R, Relay- Hi Pressure Reset 349934704 R3, 4 Relay- Hi Pressure Delay 349934704 R5.,5. Relay- Safety 349934704 R6.,6. Relay- Safety 349934704 R7., 7. Relay- Safety 349934704 R8., 8. Relay- Safety 349934704 R9, 0 Relay- Compressor Lockout 349934704 R, Relay- Speedtrol Fan Cycling (Code 47= ) 349934704 R3.,3. Relay- Safety 349934704 R4.,4. Relay- Safety 349934704 R8, 9 Relay- Cooling Failure Indicator 34993470 R0 Relay- Steam or Hot Water Heat (Code 04= S, W) 34993490 Relay- Electric Heat (Code 04= E) 34993470 Relay- Gas Heat (Code 04= A) Hi Turn Down Burner (Code 34 [Digit 5]= H, T,U) 0650800 Modulating Burner (Code 34 [Digit 5]= E, R, S 063000 R4 Relay- Gas Heat Alarm (Code 04= A) 349934704 R5 Relay- Gas Heat, Start Supply Fan Inverter (Code 4=,,3,5,6,7) 349934704 R6 Relay- Isolation Damper- Open/Close 34993490 R8 Relay- Isolation Damper Safety 34993470 R30 Relay- Cool Valve w/ Face Bypass 349934704 R45 Relay- UV Lights 34993470 R46 Relay- Inverter, Supply Fan increase/decrease (Code 4= -3,5-7) 03350 R48 Relay- Inverter, Return Fan increase/decrease (Code 4=,4,5,7-9) 03350 R6 Relay- Discharge Air Smoke Detector 34993470 R63 Relay- Specials 34993490 R64 Relay- Sump Pump 34993470 R66 Relay- Return Air Smoke Detector (Code 6=, 3) 34993470 R67 Relay- Supply Fan Enable 34993470 R68 Relay- Return Fan Enable 34993470 R69 Relay- Inverter Bypass VAV Interlock (Code 4= - 9) 349934704 R70 Relay- Specials 34993470 All R0 options are detailed here but for units with Gas Heat (Code 04= A), R0 is located in the Gas Heat Control Box (see Section G). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 68

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components, Continued Sch. Part Qty. Sym. Description Number Time Delays TD Time Delay- Compressor Lockout 300 Sec. 08038 TD Time Delay- Compressor Lockout 300 Sec. 08038 TD3 Time Delay- Hi Pressure 5 Sec. 05670 TD4 Time Delay- Hi Pressure 5 Sec. 05670 TD Time Delay- Low Ambient 65 Sec. 03358500 TD Time Delay- Low Ambient 65 Sec. 03358500 Transformers- Controls T Transformer- Control Input 5-4V 3000436 T3 Transformer- Control Output 5-4V 3000436 T4 Transformer- Exhaust Damper Actuator 5- VDC 3499380 T9 Transformer- Refrigerant Circuit 4V 3499370 Terminal Blocks TB Terminal Block- Internal 349930605 3 Sensors ZNT Sensor- Zone Temperature w/ Tenant Override 0480 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., 0480 DAT Sensor- Discharge Air Temperature 060004705 ENT Sensor- Entering Air Temperature 060004705 OAT Sensor- Outside Air Temperature 060004705 RAT Sensor- Return Air Temperature 060004705 Plugs 4 5 4 Pin Plug 3499300 varies 6 6 Pin Plug 349930403 varies 7 Pin Plug 349930405 varies 8 3 Pin Cap Kit 34993050 varies 9 6 Pin Cap Kit 349930503 varies 0 9 Pin Cap Kit 349930504 varies 5 Pin Cap Kit 349930506 varies SCC Units only- Code = BS, LS, ES, SS. Not Shown on diagram. 3 Varies depending on unit options. Part number is for one individual section. Ground Block is p/n 349930606. 4 All possible Plugs used are listed. Check actual unit to verify which Plug is required. Not shown on diagram. 5 Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 6 Used with Strain Relief (p/n 3000473) & 6 pin Cap Kit (p/n 349930503). Used for PL0, PL. 7 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n 3000475 & Cap Kit p/n 349930505). 8 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 9 Used for PL9, PL0. 0 Used for PL8, PL9, PL35, PL36, PL43. Used for PL7, PL8. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 69

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Terminal Blocks TB Terminal Block- Field 349930603 TB3 Terminal Block- Factory 349930603 TB4 Terminal Block- Field 349930603 TB7 Terminal Block- Field Convenience Outlet 349930603 Transformer- Main T Transformer- Main Control Electric, Hydronic, No Heat (Code 04= E,S,W,Y) Units without UV Lights.5KVA 03853966 Units without UV Lights.5KVA 0385399 Gas Heat (Code 04= A) Units without UV Lights.5KVA 03853967 Units without UV Lights.5KVA 0385399 Fuses- T FA, B Fuse- T Transformer, Primary Electric, Hydronic, No Heat (Code 04= E,S,W,Y) Units without UV Lights 0A 30004980 Units without UV Lights 5A 3000433 Units without UV Lights 8A 04975984 Units without UV Lights 7A 3499377 Gas Heat (Code 04= A) Units without UV Lights 5A 34993736 Units without UV Lights A 3499373 Units without UV Lights 9A 04975985 FC Fuse- T Transformer,Secondary 04753 F3 Fuse- Burner Blower Motor (Code 04= A) Fuse Block 037803 Fuse 00-000 mbh furnace 349937035 Fuse 00-000 mbh furnace 349937036 Fuse Cover 34993807 PWR Power Supply Board 5VDC 04960 Ground Fault Protection (Code 7 [Digit ]= G,B,C,D,K) GFR, Ground Fault Relay- SPDT 34993750 GFS, Ground Fault Sensor 349937407 Water Pump/Sump Heater Components M64 Contactor- Water Pump 9A 3499340 MMP64 Motor Protector- Water Pump 4-6.3A 3000435 Motor Protector- Water Pump.5-4.0A 3000434 Motor Protector- Water Pump.6-.5A 3000433 - Spacer 34990650 - Link 3499390 M65 Contactor- Sump Heater 3A 300048 Contactor- Sump Heater A 300045 Contactor- Sump Heater 7.5A 3499303 FB65 Fuse Block- Sump Heater 03780 Fuse 5A 34993736 Fuse 0A 34993735 Fuse A 3499373 Fuse 0A 3499373 Fuse Guard 34993807 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930604. For units with UV Lights (Code 7, Digit = - 9) contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 70

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Phase Voltage Monitor (Code 7 [Digit ]= P,A,C,D,H,J,K) PVM, Phase Voltage Monitor 000 Phase Voltage Monitor 000 Power Blocks PB, PB Power Block- Main (Code = P, Q) Power Block- 75A 0303770 Cover- 75A Block 34993830 Lug- 75A Block 34993800 Power Block- 55A 03037734 Cover- 55A Block 34993830 Lug- 55A Block 34993800 Power Block- 380A 0303775 Cover- 380A Block 34993830 Lug- 380A Block 34993800 Power Block- 40A 0303775 Cover- 40A Block 34993830 Lug- 40A Block 34993800 Power Block- 60A 0303770 Cover- 60A Block 349938303 3 3 3 3 Lug- 60A Block 34993800 Power Block- 760A 03037760 Cover- 760A Block 349938303 3 3 3 3 Lug- 760A Block 349938003 Power Block- 840A 0303774 Cover- 840A Block 349938303 3 3 3 3 Lug- 840A Block 349938003 PB Power Block- Power Distribution Power Block- 75A 03037705 Cover- 75A Block 34993830 Power Block- 30A 03037749 Cover- 30A Block 34993830 Power Block- 40A 0303775 Cover- 40A Block 34993830 Power Block- 760A 0303778 Cover- 760A Block 349938303 PB Power Block- Power Distribution (Code 04= E) 0, 40 KW Electric Heat 03037730 60, 80, 00 KW Electric Heat 03037744 60, 80, 00 KW Electric Heat 03037730 0 KW Electric Heat 0303775 0, 60 KW Electric Heat 03037744 00, 40, 80, 30 KW Electric Heat 0303775 PB0 Power Block- Supply Fan (Code 5= F) 0303779 PB0 Power Block- Return Fan (Code 5= F) 0303779 Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. PB is installed when code = Q. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Receptacle REC Receptacle 03900300 Disconnect Switch DS Disconnect Switch- Main (Code = A, C, D) DS Disconnect Switch- RAF/SAF (Code = C, B, D) Switch- 00A, 3 3499350 Lugs 34993590 3 3 3 3 Lug 30004488 Handle 34993550 Ground Lug 34993800 Switch- 50A 3499350 Lugs 34993590 6 6 6 6 Handle 34993550 Ground Lug 34993800 Switch- 50A 3499350 Lugs 34993600 6 6 6 6 Handle 34993550 Ground Lug 34993800 Switch- 400A 34993530 Lugs 3499360 Handle 34993560 Ground Lug 34993800 Switch- 600A 34993530 Lugs 3499360 Handle 34993560 Ground Lug 34993800 Switch- 800A 34993540 Lugs 34993640 6 6 6 6 Handle 34993570 Ground Lug 349938003 Switch- 00A, 4 349935403 Lugs 34993650 6 6 6 6 Handle 34993570 Ground Lug 349938003 Any of the listed disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and/or GO number to ensure correct replacement is selected. The Lug quantites listed are for the DS. DS use ½ the quantity plus an additional Lug: 50A Lug p/n 30004488; 50A Lug p/n 3499360; 400A Lug p/n TACL40PD3; 600A Lug p/n 34993630. 3 DS only. 4 DS only. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply Fan CB0, and Return Fan CB0 Circuit Breaker Detail Motor Horsepower 5 thru 5 Lugs Circuit Breaker 3 Plug Voltage Ref. Sch. Part Part No. Sym. Description Number Lugs 34993590 6 6 6 6 CB0 Circuit Breaker- Supply Fan CB0 Circuit Breaker- Return Fan Motor HP= 5, 7.5 34993660 Motor HP= 0, 5 34993660 Motor HP= 0, 5 34993660 Motor HP= 0, 5 349936603 Motor HP= 0, 5 34993660 Motor HP= 0 34993660 Motor HP= 5 34993660 3 Plug- Rating Motor HP= 5 34993670 Motor HP= 5, 7.5 34993670 Motor HP= 7.5 349936704 Motor HP= 0 349936705 Motor HP= 0 34993670 Motor HP= 0 34993670 Motor HP= 5 349936707 Motor HP= 5 349936704 Motor HP= 5 34993670 Motor HP= 0 349936709 Motor HP= 0 349936708 Motor HP= 5 34993670 Motor HP= 5 349936709 Motor HP= 0, 5 349936705 Motor HP= 0 349936704 Motor HP= 5 349936705 Circuit Breakers are only used when a Fan Motor has an Inverter (Code 4= - 9). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 73

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply Fan CB0, and Return Fan CB0 Circuit Breaker Detail Motor Horsepower 30 thru 75 Lugs Circuit Breaker 3 Plug Voltage Ref. Sch. Part Part No. Sym. Description Number Lugs 34993590 6 6 6 6 CB0 Circuit Breaker- Supply Fan CB0 Circuit Breaker- Return Fan Motor HP= 30 34993660 Motor HP= 30 349936603 Motor HP= 30, 40 349936604 Motor HP= 40 349936604 Motor HP= 40, 50 349936603 Motor HP= 30, 40, 50 34993660 Motor HP= 60, 75 349936603 3 Plug- Rating Motor HP= 30 349936705 Motor HP= 30 349936706 Motor HP= 30 3499367 Motor HP= 30 3499367 Motor HP= 40 34993674 Motor HP= 40 349936708 Motor HP= 40 349936706 Motor HP= 50 349936707 Motor HP= 50 349936709 Motor HP= 60 349936709 Motor HP= 60 34993670 Motor HP= 75 3499367 Circuit Breakers are only used when a Fan Motor has an Inverter (Code 4= - 9). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 74

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Diagrams Short Circuit 3C Alarm Aux. Contact NO/NC Aux. Contact 3D D MMP 3 Line 3A Shield 3B Link Contactor A Cover Short Circuit Alarm 3C NO/NC Aux. Contact D 3 MMP 3E 3B Front Mounted Contact Link Contactor A Cover MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- All Voltages 7.5 HP Motor- 30/460/ 0, 5 HP Motors- 460/ MMP0 & M0 Link Detail MMP0 & M0 Link Detail 7.5 HP Motors- 0, 5 HP Motors- 08/ 0, 5, 30 HP Motors- 460/ 40 HP Motors- 3 MMP 3E Front Mounted Contact 3G Lug 3 MMP 3G 3 Lug MMP Short Circuit Alarm 3C Contactor NO/NC Aux. Contact D 3F Trip Ind. Interlock Contactor 3F Trip Ind. Interlock 3G Lug NO/NC Aux. Contact D Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 0 HP Motors- 08/ 5 HP Motors- 40 HP Motors- 50 HP Motors- 460/ 60 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 30 HP Motors- 08/ 40 HP Motors- 60 HP Motors- 75 HP Motors- 460/ MMP0 & M0 Link Detail 40 HP Motors- 50 HP Motors- 08/ 60 HP- 08/ The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 75

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components 5 HP Motor- Code OR 3= J** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499330 Contactor- Supply (M0) OR Return (M0) Fan 349930 Contactor- Supply (M0) OR Return (M0) Fan 349930 A Cover- Contactor 34993803 Cover- Contactor 3499380 Cover- Contactor 3499380 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 3000438 MMP- Supply (MMP0) OR Return (MMP0) Fan 3000436 MMP- Supply (MMP0) OR Return (MMP0) Fan 3000435 3A Line Shield 34993300 3B Link 30004308 Link 3499390 3C Short Circuit Alarm 3000498 3D Aux. Interlock- NO/ NC 34993390 7.5 HP Motor- Code OR 3= K** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499340 Contactor- Supply (M0) OR Return (M0) Fan 3499330 Contactor- Supply (M0) OR Return (M0) Fan 349930 A Cover- Contactor 34993804 Cover- Contactor 34993803 Cover- Contactor 3499380 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993405 MMP- Supply (MMP0) OR Return (MMP0) Fan 3000430 MMP- Supply (MMP0) OR Return (MMP0) Fan 3499340 MMP- Supply (MMP0) OR Return (MMP0) Fan 3000436 3A Line Shield 34993300 3B Link 34993906 Link 30004308 Link 3499390 3C Short Circuit Alarm 3000498 3D Aux. Interlock- NO/ NC 34993390 3E OL Circuit Alarm- Front 349933804 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 76

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 0 HP Motor- Code OR 3= L** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499350 Contactor- Supply (M0) OR Return (M0) Fan 349930 Contactor- Supply (M0) OR Return (M0) Fan 349930 A Cover- Contactor 34993805 Cover- Contactor 3499380 Cover- Contactor 3499380 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993406 MMP- Supply (MMP0) OR Return (MMP0) Fan 3000438 MMP- Supply (MMP0) OR Return (MMP0) Fan 3499340 3A Line Shield 34993300 3B Link 34993907 Link 34993903 Link 3499390 3C Short Circuit Alarm 3000498 3D Aux. Interlock- NO/ NC 34993390 3E OL Circuit Alarm- Front 349933804 5 HP Motor- Code OR 3= M** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499350 Contactor- Supply (M0) OR Return (M0) Fan 3499330 A Cover- Contactor 34993805 Cover- Contactor 34993803 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 3000438 MMP- Supply (M0) OR Return (M0) Fan 3000430 MMP- Supply (M0) OR Return (M0) Fan 3000439 3A Line Shield 34993300 3B Link 34993907 Link 30004308 3C Short Circuit Alarm 3000498 3D Aux. Interlock- NO/ NC 34993390 3E OL Circuit Alarm- Front 349933804 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 77

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 0 HP Motor- Code OR 3= N** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499360 Contactor- Supply (M0) OR Return (M0) Fan 3499350 A Cover- Contactor 34993805 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 34993409 MMP- Supply (M0) OR Return (M0) Fan 3000438 MMP- Supply (M0) OR Return (M0) Fan 34993406 MMP- Supply (M0) OR Return (M0) Fan 34993405 3B Link 34993907 3C Short Circuit Alarm 3000498 3E OL Circuit Alarm- Front 349933804 5 HP Motor- Code OR 3= P** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499360 Contactor- Supply (M0) OR Return (M0) Fan 3499350 A Cover- Contactor 34993805 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938606 MMP- Supply (M0) OR Return (M0) Fan 34993409 MMP- Supply (M0) OR Return (M0) Fan 300043300 MMP- Supply (M0) OR Return (M0) Fan 34993406 3B Link 34993907 3C Short Circuit Alarm 3000498 3E OL Circuit Alarm- Front 349933804 3F Trip Indicator Interlock 34993870 3G Lug (3 per kit) 34993880 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 78

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 30 HP Motor- Code OR 3= Q** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499360 Contactor- Supply (M0) OR Return (M0) Fan 3499360 Contactor- Supply (M0) OR Return (M0) Fan 3499350 Contactor- Supply (M0) OR Return (M0) Fan 3499350 A Cover- Contactor 34993805 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938606 MMP- Supply (M0) OR Return (M0) Fan 300043300 3B Link 34993907 3C Short Circuit Alarm 3000498 3E OL Circuit Alarm- Front 349933804 3F Trip Indicator Interlock 34993870 3G Lug (3 per kit) 34993880 40 HP Motor- Code OR 3= R** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499370 Contactor- Supply (M0) OR Return (M0) Fan 3499360 Contactor- Supply (M0) OR Return (M0) Fan 3499360 Contactor- Supply (M0) OR Return (M0) Fan 3499350 A Cover- Contactor 34993805 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 349938607 MMP- Supply (MMP0) OR Return (MMP0) Fan 3000438 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993409 3B Link 34993907 3C Short Circuit Alarm 3000498 3E OL Circuit Alarm- Front 349933804 3F Trip Indicator Interlock 34993870 3G Lug (3 per kit) 34993880 Also requires 3 field supplied ring terminals. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 79

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 50 HP Motor- Code OR 3= S** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499370 Contactor- Supply (M0) OR Return (M0) Fan 3499360 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 349938607 MMP- Supply (MMP0) OR Return (MMP0) Fan 3000438 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993409 3C Short Circuit Alarm 3000498 3E OL Circuit Alarm- Front 349933804 3F Trip Indicator Interlock 34993870 3G Lug (3 per kit) 34993880 Also requires 3 field supplied ring terminals. 60 HP Motor- Code 3 OR 3 = T** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499370 Contactor- Supply (M0) OR Return (M0) Fan 3499360 Contactor- Supply (M0) OR Return (M0) Fan 3499360 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 349938608 MMP- Supply (MMP0) OR Return (MMP0) Fan 349938606 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993409 3C Short Circuit Alarm 3000498 3E OL Circuit Alarm- Front 349933804 3F Trip Indicator Interlock 34993870 3G Lug 34993880 3 3 6 Also requires 3 field supplied ring terminals. 75 HP Motor- Code 3= U** Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 3499360 3 MMP0 MMP- Supply Fan 349938606 3F Trip Indicator Interlock 34993870 3G Lug 34993880 6 6 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 80

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Compressor MMP- 4 and Contactor M- 4 Diagrams Short Circuit 3C Alarm Aux. Contact NO/NC Aux. Contact 3D D NO Front Aux. Contact MMP 3 Line 3A Shield 3B C Link MMP- 4 & M- 4 Link Detail 0C- Contactor A Cover B NC Front Aux. Contact Short Circuit Alarm 3C NO/NC Aux. Contact D NO Front Aux.Contact 3 MMP C 3E 3B Front Mounted Contact Link Contactor A B MMP- 4 & M- 4 Link Detail 076C, 30C- All Voltages 089C- 30/460/ 00C- 0C- 08/30/ 40C Cir. #- All Voltages 40C Cir. #- 30/460/ 50C- 30/460/ Cover NC Front Aux. Contact 3 MMP 3E Front Mounted Contact 3G Lug 3 MMP Short Circuit Alarm 3C Contactor NO/NC Aux. Contact D 3F Trip Ind. Interlock Contactor NO/NC Aux. Contact D NO Front Aux. Contact C B NC Front Aux. Contact MMP- 4 & M- 4 Link Detail 089C- 00C- 30/ 40C Cir. #- 50C- NO Front Aux. Contact C B NC Front Aux. Contact MMP- 4 & M- 4 Link Detail 00C- The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Compressor MMP- 4 and Contactor M- 4 Components Unit Size 076 089 00 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor 80A 3499360 Contactor 68A 34993503 Contactor 6A 30004 Contactor 48A 3499350 A Cover- Contactor 34993805 B Aux. Contact, Front- NC 3000407 C Aux. Contact, Front- NO 3000408 Compressor MMP s & Parts 3 MMP, Manual Motor Protector 63-00A 349938606 Manual Motor Protector 50-63A 34993409 Manual Motor Protector 40-50A 3000438 Manual Motor Protector 5-40A 300043300 3B Link 34993907 3C Short Circuit Alarm 3000498 3E Front Mounted Contact- NO 34993380 3F Trip Indicator 34993870 3G Lug Kit (3 lugs per kit) 34993880 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Compressor MMP- 4 and Contactor M- 4 Components, Continued Unit Size 0 30 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor 6A 30004 4 4 4 4 4 Contactor 48A 3499350 4 4 Contactor 3A 300048 4 A Cover- Contactor 34993805 4 4 4 4 4 4 4 Cover- Contactor 34993803 4 B Aux. Contact, Front- NC 3000407 4 Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector 40-50A 3000438 4 4 4 Manual Motor Protector 5-40A 300043300 4 4 4 4 Manual Motor Protector 4-3A 300040948 4 3A Line Shield 30004300 4 3B Link 34993907 4 4 4 4 4 4 4 3C Short Circuit Alarm 3000498 4 4 4 4 4 4 4 4 3D Front Mounted Contact- NO/NC 3000496 4 3E Front Mounted Contact- NO 34993380 4 4 4 4 4 4 4 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 83

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Compressor MMP- 4 and Contactor M- 4 Components, Continued Unit Size 40 50 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor 68A 34993503 Contactor 6A 30004 Contactor 48A 3499350 M3, 4 Contactor 68A 34993503 Contactor 6A 30004 Contactor 48A 3499350 A Cover- Contactor 34993805 4 4 4 4 4 4 Compressor MMP s & Parts 3 MMP, Manual Motor Protector 50-63A 34993409 Manual Motor Protector 40-50A 3000438 Manual Motor Protector 5-40A 300043300 MMP3, 4 Manual Motor Protector 50-63A 34993409 Manual Motor Protector 40-50A 3000438 Manual Motor Protector 5-40A 300043300 3B Link 34993907 4 4 4 4 4 4 3C Short Circuit Alarm 3000498 4 4 4 4 4 4 4 4 3E Front Mounted Contact- NO 34993380 4 4 4 4 4 4 4 4 For unit size 40C, M, & MMP, are for the 30HP Compressors; M3, 4 & MMP3, 4 are for the 35HP Compressors. 4pc. used on Circuit # only. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 84

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB MMP 3 3A Line Shield 6 Lugs Short Circuit Alarm 3C 3B Link 5 Circuit Breaker Spacer 4 Contactor 7 Plug Unit Size 076-00 0-50 Ref. Sch. Part Part No. Sym. Description Number Fan Contactors M, Contactor- Condenser Fan 9A 3499340 M3, 3 Contactor- Condenser Fan 9A 3499340 Fan MMP s & Parts 3 MMP, Manual Motor Protector 4.0-6.3A 3000435 Manual Motor Protector.5-4.0A 3000434 Manual Motor Protector.6-.5A 3000433 MMP, Manual Motor Protector 4.0-6.3A 3000435 Manual Motor Protector.5-4.0A 3000434 Manual Motor Protector.6-.5A 3000433 MMP3, 3 Manual Motor Protector 4.0-6.3A 3000435 Manual Motor Protector.5-4.0A 3000434 Manual Motor Protector.6-.5A 3000433 3A Line Shield- MMP 30004300 4 4 4 6 6 6 3B Link- MMP 3499390 4 4 4 6 6 6 3C Short Circuit Alarm- MMP 3000498 4 4 4 6 6 6 4 Spacer- Contactor 34990650 8 8 8 Fan Circuit Breaker & Parts 5 CB Circuit Breaker- Condenser Fan 3000485 6 Lugs- Circuit Breaker 300040959 7 Plug- Circuit Breaker 34993670 Also requires 3 field supplied ring terminals. 08/ 08/ RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 85

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Diagram The above diagram shows a typical four compressor (size 0-50C) Main Control Box layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 86

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Control Box Component Label Diagram Note that starting in late 00 all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 87

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller 0600060 Com Card- Bacnet (Code = B*) 0600060 Com Card- Bacnet with Ethernet (Code = E*) 0600060 Com Card- LonMark Space Control (Code = LS) 06000603 Com Card- LonMark Discharge Control (Code = LD) 06000604 Standoff- Com Card 04866706 4 Kit- Connector Repair 300036605 Power Supply- 5 VDC 04960 Serial Port Ribbon Cable 0470 Battery 04975450 Grounding Bar 34993690 Keypad Keypad Keypad 06000630 Remote Keypad Interface Board 060 Cable- Interface 34993850 Compressor Controller CCB, Expansion Board- Compressor Controller 060 Fuse- Expansion Board 0650 Standoff- Expansion Board 04866705 4 Comm. Card- Bacnet 0600060 Standoff- Comm. Card 04866707 8 RES Resistor- CCB 06000390 Electric Heat Board EHB Expansion Board- Electric Heat 060 Standoff- Expansion Board 04866705 7 Expansion Board Comm. Card- Bacnet 0600060 Standoff- Comm. Card 04866707 4 Switches- Control HS Switch- Electric Heat Shutdown (Code 04=E) 80005045 PS, Switch- Pumpdown 80005045 CS, Switch- Control 08446400 S Switch- System On/Off Gas Heat Units (Code 04= A) 08446400 Elec.,Steam,HW, No Heat (Code 04= E,S,W,Y) 80005045 S4 Switch- Inverter Bypass On/Off 08798400 S7 Switch- Local On/Auto/Off to Controller 349930 Serial Cables Serial Serial Cable 0470 Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch 06549380 SPS Pressure Transducer- Duct Sensor (Code 3=,, 3) 049545007 SPS Pressure Transducer- Duct Sensor (Code 3= ) 049545007 Pressure Transducer- Space Sensor (Code 3= 3, 4) 049545006 This Controller must be programmed in order to function correctly. When ordering a replacement, provide the unit model and serial number so the unit specific software code can be loaded before shipment. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 88

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R, Relay- Hi Pressure Reset 34993474 R3, 4 Relay- Hi Pressure Delay 34993474 R5., 5. Relay- Safety 34993474 R6., 6. Relay- Safety 34993474 R7., 7. Relay- Safety 34993474 R8., 8. Relay- Safety 34993474 R9, 0 Relay- Compressor Lockout 34993474 R, Relay- Speedtrol Fan Cycling (Code 47= ) 34993474 R3.,3. Relay- Safety 34993474 R4.,4. Relay- Safety 34993474 R8, 9 Relay- Cooling Failure Indicator 3499347 R0 Relay- Steam or Hot Water Heat (Code 04= S, W) 3499349 Relay- Electric Heat (Code 04= E) 3499347 Relay- Gas Heat (Code 04= A) Hi Turn Down Burner (Code 34 [Digit 5]= H,T, U) 0650800 Modulating Burner (Code 34 [Digit 5]= E, R,S) 063000 R4 Relay- Gas Heat Alarm (Code 04= A) 34993474 R5 Relay- Gas Heat, Start Supply Fan Inverter (Code 4=,,3,5,6,7) 34993474 R6 Relay- Isolation Damper- Open/Close 3499349 R8 Relay- Isolation Damper Safety 3499347 R30 Relay- Cool Valve w/ Face Bypass 34993474 R45 Relay- UV Lights 3499347 R46 Relay- Inverter, Supply Fan increase/decrease (Code 4= -3, 5-7) 03350 R48 Relay- Inverter, Return Fan increase/decrease (Code 4=,4,5,7-9) 03350 R6 Relay- Discharge Air Smoke Detector 3499347 R63 Relay- Specials 3499349 R64 Relay- Sump Pump 34993470 R66 Relay- Return Air Smoke Detector (Code 6=, 3) 3499347 R67 Relay- Supply Fan Enable 3499347 R68 Relay- Return Fan Enable 3499347 R69 Relay- Inverter Bypass VAV Interlock (Code 4= - 9) 3499347 R70 Relay- Specials 3499347 All R0 options are detailed here but for units with gas heat, the R0 is located in the Gas Heat Control Box (see section G). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 89

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Qty. Sym. Description Number Time Delays TD Time Delay- Compressor Lockout 300 Sec. 08038 TD Time Delay- Compressor Lockout 300 Sec. 08038 TD3 Time Delay- Hi Pressure 5 Sec. 05670 TD4 Time Delay- Hi Pressure 5 Sec. 05670 TD Time Delay- Low Ambient 65 Sec. 03358500 TD Time Delay- Low Ambient 65 Sec. 03358500 Transformers- Controls T Transformer- Control Input 5-4V 3000436 T3 Transformer- Control Output 5-4V 3000436 T4 Transformer- Exhaust Damper Actuator 5- VDC 3499380 T9 Transformer- Refrigerant Circuit 4V 3499370 Terminal Blocks TB Terminal Block- Internal 34993064 3 TB, 7 Terminal Block 34993064 4 TB3, 4 Terminal Block 34993064 5 Sensors ZNT Sensor- Zone Temperature w/ Tenant Override 0480 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., 0480 DAT Sensor- Discharge Air Temperature 060004705 ENT Sensor- Entering Air Temperature 060004705 OAT Sensor- Outside Air Temperature 060004705 RAT Sensor- Return Air Temperature 060004705 SCC Units only (Code = *S). Not Shown on diagram. 3 Varies depending on unit options. Part number is for one individual section. Ground Block is p/n 349930647. Jumpers are p/n 349930945 (TBA:5), 349930943 (TBB:4), 34993094 (TBC:0,TBD:5 & TBE:30). 4 Varies depending on unit options. Part number is for one individual section. Ground Block is p/n 349930647. 5 Varies depending on unit options. Part number is for one individual section. When required, Jumpers are p/n 3499309 ( pole), 34993093 (3 pole), 34993094 (4 pole), 34993095 (5 pole). RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 90

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Transformer- Main T Transformer- Main Control Electric, Hydronic, No Heat (Code 04= E,S,W,Y) Units without UV Lights 03853975 Units without UV Lights 03853957 Units without UV Lights 03853984 Units with UV Lights (Code 7 [Digit ]= - 8) 03853976 Units with UV Lights (Code 7 [Digit ]= - 8) 03853958 Units with UV Lights (Code 7 [Digit ]= - 8) 03853985 Gas Heat (Code 04= A) Units without UV Lights 03853976 Units without UV Lights 03853958 Units without UV Lights 03853985 Units with UV Lights (Code 7 [Digit ]= - 8) 34993989 Units with UV Lights (Code 7 [Digit ]= - 8) 349939809 Units with UV Lights (Code 7 [Digit ]= - 8) 34993989 Fuses- T FA,B Fuse- T Transformer, Primary Electric, Hydronic, No Heat (Code 04= E,S,W,Y) Units without UV Lights 34993734 Units without UV Lights 34993733 Units without UV Lights 3499379 Units without UV Lights 3499375 Units with UV Lights (Code 7 [Digit ]= - 8) 34993735 Units with UV Lights (Code 7 [Digit ]= - 8) 3499373 Units with UV Lights (Code 7 [Digit ]= - 8) 3499379 Gas Heat (Code 04= A) Units without UV Lights 34993735 Units without UV Lights 3499373 Units without UV Lights 3499379 Units with UV Lights (Code 7 [Digit ]= - 8) 34993737 3 3 Units with UV Lights (Code 7 [Digit ]= - 8) 34993733 3 Units with UV Lights (Code 7 [Digit ]= - 8) 3499373 3 FC Fuse- T Transformer, Secondary 349937038 Fuse- T Transformer, Secondary 349937036 Fuse- T Transformer, Secondary 349937035 Water Pump/Sump Heater Components M64 Contactor- Water Pump 9A 34993 MMP64 Motor Protector- Water Pump 4-5.9A 349934049 Motor Protector- Water Pump.5-3.9A 349934048 Motor Protector- Water Pump.6-.4A 349934047 - Spacer 34990650 - Link 349939 M65 Contactor- Sump Heater 5A 349933 Contactor- Sump Heater 8A 349933 Contactor- Sump Heater 9A 34993 FB65 Fuse Block- Sump Heater 03780 Fuse 5A 34993736 Fuse 0A 34993735 Fuse A 3499373 Fuse 0A 3499373 Fuse Guard 3499387 T Transformers also use a Cover kit p/n 34995590 & a Fuse Puller kit p/n 34995580 (not used on Transformer p/ns 34993989, 349939809, 34993989). Fuse depends on heat type and presence of UV lights. 349937038= Gas Heat Unit w/uv lights; 349937036= Gas Heat Unit with no UV lights OR Non-Gas Heat Unit with UV lights; 349937035= Non- Gas Heat Units with no UV lights. 3 Fuses used on Gas Heat Unit w/uv lights also use Fuse Block p/n 037803 & 3 Pullers p/n 3499387. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 9

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Fuses F,F3, F5 Fuses Fuse Block 037803 /fuse /fuse /fuse /fuse Fuse Cover 3499387 /fuse /fuse /fuse /fuse F Fuse- 000+VA Transformer 349937035 F3 Fuse- Blower Motor 00-500 mbh furnace 349937035 F3 Fuse- Blower Motor 000 mbh furnace 349937036 F5 Fuse- UV Lights (Code 7 [Digit ]= - 8) 34993703 Phase Voltage Monitor (Code 7= P,A,C,D,H,J,K) PVM, Phase Voltage Monitor 000 Phase Voltage Monitor 000 Ground Fault Protection (Code 7= G,B,C,D,K) GFR, Ground Fault Relay- SPDT 34993750 GFS, Ground Fault Sensor 349937407 Power Blocks PB, PB Power Block- Main (Code = P, Q) Power Block, Non- Electric Heat Units- 75A 03037776 Power Block, Electric Heat Units- 75A 03037780 Lug- 75A Block 34993800 Power Block, Non- Electric Heat Units- 55A 03037778 Lug- 55A Block 34993800 Power Block, Non- Electric Heat Units- 380A 03037779 Power Block, Electric Heat- 380A 0303778 Lug- 380A Block 34993800 Power Block, Non- Electric Heat Units- 60A 0303770 Cover- 60A Block 349938345 3 3 3 3 Lug- 60A Block 34993800 Power Block, Non- Electric Heat Units- 760A 03037760 Power Block, Electric Heat Units, 08/- 760A 0303777 Power Block, Electric Heat Units, 460/- 760A 03037760 Cover- 760A Block 349938345 3 3 3 3 Lug- 760A Block 349938003 Power Block, Non- Electric Heat Units- 840A 0303774 Cover- 840A Block 349938345 3 3 3 3 Lug- 840A Block 349938003 PB Power Block- Power Distribution Power Block- 40A 03037785 Power Block- 760A 030377 Cover- 760A Block 349938345 PB Power Block- Power Distribution (Code 04= E) 0, 40 KW Electric Heat 03037777 60, 80, 00, 0 KW Electric Heat 03037785 60, 80, 00, 0 KW Electric Heat 03037777 60, 00, 40, 80, 30 KW Electric Heat 03037785 Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. PB is installed when Code = Q. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 9

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Power Blocks, continued PB0 Power Block- Supply Fan (Code 5= F) 03037776 PB0 Power Block- Return Fan (Code 5= F) 03037776 Receptacles REC Receptacle 039003600 Power Supply Board PWR Power Supply Board 5VDC 04960 Disconnect Switch DS Disconnect Switch- Main Gas, Steam, HW, No Heat (Code 04= A, S, W, Y) Switch- 00A 3499355 Handle Kit 3499355 Shaft 3499604 Ground Lug 34993800 Switch- 50A 3499356 Handle Kit (with operating mechanism) 34993553 Shaft 3499605 Ground Lug 34993800 Switch- 50A 3499356 Handle Kit (with operating mechanism) 34993553 Shaft 3499605 Ground Lug 34993800 Switch- 400A 34993535 Handle Kit (with operating mechanism) 3499356 Shaft 3499606 Ground Lug 34993800 Switch- 600A,, 3 9343805 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 3499607 Ground Lug 34993800 Switch- 800A, 3 934380 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 349964 Ground Lug 349938003 Switch- 000A, 3 9343806 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 349964 Ground Lug 349938003 Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. The 600A switch listed is used on units with one Disconnect or two Disconnects EH/balance of unit (code = A or B). If unit has two Disconnects where the second Disconnect controls the fans (Code = C) or 3 Disconnects (Code = D) then use Switch p/n 9343800, Handle kit p/n 9343790, Shaft p/n 3499633, and Ground Lug p/n 34993800. 3 Note that the original Disconnect is obsolete. If replacing an original part, due to dimensional differences, minor field modifications may be required for proper installation. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 93

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Disconnect Switch, continued DS Disconnect Switch- Main Electric Heat (Code 04= E) Switch- 00A 349935 Handle Kit 3499355 Shaft 3499604 Ground Lug 34993800 Load Lug 3499560 Cover- Load Lug 349957003 Switch- 50A 349935 Handle Kit 34993553 Shaft 3499605 Ground Lug 34993800 Load Lug 3499560 Cover- Load Lug 34995700 Switch- 50A 349935 Handle Kit 34993553 Shaft 3499605 Ground Lug 34993800 Load Lug 34995630 Cover- Load Lug 34995700 Switch- 400A 34993535 Handle Kit 3499356 Shaft 3499606 Ground Lug 34993800 Switch- 600A,, 3 9343805 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 3499607 Ground Lug 34993800 Switch- 800A, 3 934380 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 349964 Ground Lug 349938003 Switch- 000A, 3 9343806 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 349964 Ground Lug 349938003 Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. The 600A Switch listed is used on units with one Disconnect OR two Disconnects EH/balance of unit (Code = A, B). If unit has two Disconnects where the second Disconnect controls the fans (Code = C) OR 3 Disconnects (Code = D) then use Switch p/n 9343800, Handle kit p/n 9343790, Shaft p/n 3499633, and Ground Lug p/n 34993800. 3 Note that the original Disconnect is obsolete. If replacing an original part, due to dimensional differences, minor field modifications may be required for proper installation. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 94

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Disconnect Switch, continued DS Disconnect Switch- SAF/RAF (Code = C, D) Switch- 00A 349935 Handle Kit 3499355 Shaft 3499604 Ground Lug 34993800 Load Lug 3499560 Cover- Load Lug 349957003 Switch- 50A 349935 Handle Kit 34993553 Shaft 3499605 Ground Lug 34993800 Load Lug 3499560 Cover- Load Lug 34995700 Switch- 50A 349935 Handle Kit 34993553 Shaft 3499605 Ground Lug 34993800 Load Lug 34995630 Cover- Load Lug 34995700 Switch- 400A 3499353 Handle Kit 3499356 Shaft 3499606 Ground Lug 34993800 Load Lug 34995640 3 3 3 3 Cover- Load Lug 349957004 Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 95

Section N- Controls MicroTech II: Code = *D, *S- 4/05 thru /06 Supply Fan CB0, and Return Fan CB0 Circuit Breaker & Plugs Sch. Part Part Voltage Sym. Description Number Circuit Breakers- Supply & Return Fan CB0 CB0 Circuit Breaker- Supply Fan Circuit Breaker- Return Fan Motor HP= 5, 7.5, 0 34993960 Motor HP= 5 3499396 Motor HP= 5, 7.5 3499396 Motor HP= 7.5 34993964 Motor HP= 0 34993966 Motor HP= 0 3499396 Motor HP= 5 34993969 Motor HP= 5 34993964 Motor HP= 5, 0 349939604 Motor HP= 0 34993963 Motor HP= 0 349939630 Motor HP= 0, 5 34993966 Motor HP= 5 34993963 Motor HP= 5 34993963 Motor HP= 5, 30 349939606 Motor HP= 30 34993970 Motor HP= 30 349939633 Motor HP= 30 34993968 Motor HP= 40 349939703 Motor HP= 40 349939630 Motor HP= 40 349939608 Motor HP= 50 34993963 Motor HP= 50 34993960 Motor HP= 60 34993963 Motor HP= 60 3499396 Motor HP= 75 34993970 Plugs 4 Pin Plug 3499300 varies varies varies varies 3 6 Pin Plug 349930403 varies varies varies varies 4 Pin Plug 349930405 varies varies varies varies 5 3 Pin Cap Kit 34993050 varies varies varies varies 6 6 Pin Cap Kit 349930503 varies varies varies varies 7 9 Pin Cap Kit 349930504 varies varies varies varies 8 5 Pin Cap Kit 349930506 varies varies varies varies All possible Plugs used are listed. Check installed part to verify. Not shown on diagram. Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 3 Used with Strain Relief (p/n 3000473) & 6 pin cap kit (p/n 349930503). Used for PL0, PL. 4 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n 3000475 & Cap kit p/n 349930505). 5 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 6 Used for PL9, PL0. 7 Used for PL8, PL9, PL35, PL36, PL43. 8 Used for PL7, PL8. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 96

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Diagrams Front Mtd. Contact 3E Aux. Contact Line Shield 3D 3A 3 MMP Front Mounted Contact 3E Link 3B 4 Spacer MMP 3 Contactor Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 3-0 HP Motors- All Voltages 5, 0 HP Motor- 460/ 5, 30 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5, 0 HP Motors- 08/ 5 HP Motors- 30/ 30 HP Motors- 40 HP Motors- 460/ 50 HP Motors- 460/ 60HP Motors- MMP 3 Lug 3G 3G 3 Lug MMP Trip Indicator Alarm 3F 3F Trip Ind. Interlock 3G Lug Contactor Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 30, 40 HP Motors- 08/ 50 HP Motor- 60HP Motors- 75 HP Motors- 460/ MMP0 & M0 Link Detail 50HP Motors- 60HP Motors- 08/ The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 97

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components 3 HP Motor- Code = H** Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Return Fan 34993 Contactor- Return Fan 34993 3 MMP0 MMP- Return Fan 349934050 MMP- Return Fan 349934049 MMP- Return Fan 349934048 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 5 HP Motor- Code OR 3= J** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 34993 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993405 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993405 MMP- Supply (MMP0) OR Return (MMP0) Fan 349934050 MMP- Supply (MMP0) OR Return (MMP0) Fan 349934049 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 7.5 HP Motor- Code OR 3= K** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 34993 Contactor- Supply (M0) OR Return (M0) Fan 34993 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 349934053 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993405 MMP- Supply (MMP0) OR Return (MMP0) Fan 349934050 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 98

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 0 HP Motor- Code OR 3= L** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 34993 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 349934055 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993405 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 5 HP Motor- Code OR 3= M** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349935 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 349933 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 34993448 MMP- Supply (M0) OR Return (M0) Fan 34993447 MMP- Supply (M0) OR Return (M0) Fan 349934053 MMP- Supply (M0) OR Return (M0) Fan 34993405 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 0 HP Motor- Code OR 3= N** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499353 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 349933 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 34993449 MMP- Supply (M0) OR Return (M0) Fan 34993448 MMP- Supply (M0) OR Return (M0) Fan 349934054 MMP- Supply (M0) OR Return (M0) Fan 349934053 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 99

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 5 HP Motor- Code OR 3= P** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349936 Contactor- Supply (M0) OR Return (M0) Fan 349935 Contactor- Supply (M0) OR Return (M0) Fan 349933 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938606 MMP- Supply (M0) OR Return (M0) Fan 34993449 MMP- Supply (M0) OR Return (M0) Fan 349934055 MMP- Supply (M0) OR Return (M0) Fan 349934054 3B Link 349939 3E Aux. Contact- NO or NC 3499338 3F Trip Indicator Alarm 34993870 3G Lug (3 per kit) 34993880 30 HP Motor- Code OR 3= Q** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349937 Contactor- Supply (M0) OR Return (M0) Fan 349936 Contactor- Supply (M0) OR Return (M0) Fan 349935 Contactor- Supply (M0) OR Return (M0) Fan 349933 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938606 MMP- Supply (M0) OR Return (M0) Fan 34993447 MMP- Supply (M0) OR Return (M0) Fan 349934055 3B Link 349939 3E Aux. Contact- NO or NC 3499338 3F Trip Indicator Alarm 34993870 3G Lug (3 per kit) 34993880 4 Spacer 34990650 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 00

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 40 HP Motor- Code OR 3= R** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349937 Contactor- Supply (M0) OR Return (M0) Fan 349937 Contactor- Supply (M0) OR Return (M0) Fan 349935 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938607 MMP- Supply (M0) OR Return (M0) Fan 349938606 MMP- Supply (M0) OR Return (M0) Fan 34993448 MMP- Supply (M0) OR Return (M0) Fan 34993447 3E Aux. Contact- NO or NC 3499338 3F Trip Indicator Alarm 34993870 3G Lug (3 per kit) 34993880 Also requires 3 field supplied ring terminals. 50 HP Motor- Code OR 3= S** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499370 Contactor- Supply (M0) OR Return (M0) Fan 349937 Contactor- Supply (M0) OR Return (M0) Fan 349936 Contactor- Supply (M0) OR Return (M0) Fan 3499353 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938607 MMP- Supply (M0) OR Return (M0) Fan 34993449 3E MMP- Supply (M0) OR Return (M0) Fan 34993448 3E Aux. Contact- NO or NC 3499338 3F Trip Indicator Alarm 34993870 3G Lug (3 per kit) 34993880 Also requires 3 field supplied ring terminals. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 0

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 60 HP Motor- Code OR 3= T** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499370 Contactor- Supply (M0) OR Return (M0) Fan 349936 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938608 MMP- Supply (M0) OR Return (M0) Fan 349938607 MMP- Supply (M0) OR Return (M0) Fan 349938606 MMP- Supply (M0) OR Return (M0) Fan 34993449 3E Aux. Contact- NO or NC 3499338 3F Trip Indicator Alarm 34993870 3G Lug (3 per kit) 34993880 Lug (3 per kit) 34993880 Also requires 3 field supplied ring terminals PER kit. 75 HP Motor- Code 3= U** Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 349937 3 MMP0 MMP- Supply Fan 349938606 3F Trip Indicator Alarm 34993870 3G Lug 34993880 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 0

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Compressor MMP- 4 and Contactor M- 4 MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- & M- Link Detail 076C- 08/ 089C, 00C- 08/30/ MMP- & M- Link Detail 076C- 460/ 089C, 00C- Unit Size 076 089 00 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor 3 3 3 Contactor 50A 349937 Contactor 4 5A 349937 Contactor 4 80A 349936 Contactor 4 65A 3499353 Compressor MMP s & Parts 3 MMP, Motor Protector 50-0A 349938608 Motor Protector 90-50A 349938607 Motor Protector 4 60-00A 349938606 Motor Protector 4 50-65A 34993449 Motor Protector 40-50A 34993448 3E Aux. Contact- NO or NC 4 34993870 Front Mounted Contact- NO 4 3499338 3G Lug Kit (3 lugs per kit) 4 34993880 The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. 3 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. 4 On 7/09 the amp ratings for Compressor Contactors and Motor Protectors were revised. When replacing an original Contactor OR MMP, it is recommended that the Contactor and MMP be replaced with the above listed uprated components. For 35 and 40HP compressors, in addition to the Contactor and MMP, the Auxiliary and Lug Kit MUST also be ordered. Refer to the Compressor listing in Section M to determine Compressor horsepower. 4 4 4 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 03

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Compressor MMP- 4 and Contactor M- 4, Continued MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- 4 & M- 4 Link Detail 0C, 30C- 08/ MMP- 4 & M- 4 Link Detail 0C, 30C- 460/ Unit Size 0 30 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor 50A 349937 4 4 Contactor 5A 349937 4 4 Contactor 3 65A 3499353 4 4 Contactor 3 50A 349935 4 4 Compressor MMP s & Parts 3 MMP- 4 Motor Protector 90-50A 349938607 4 4 4 Motor Protector 60-00A 349938606 4 Motor Protector 3 50-65A 34993449 4 Motor Protector 3 40-50A 34993448 4 4 Motor Protector 30-40A 34993447 4 3E Aux. Contact- NO or NC 34993870 4 4 Front Mounted Contact- NO 3 3499338 4 4 4 4 3G Lug Kit (3 lugs per kit) 34993880 4 4 4 4 3 3 The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. 3 On 7/09 the amp ratings for Compressor Contactors and Motor Protectors were revised. When replacing an original Contactor OR MMP, it is recommended that the Contactor and MMP be replaced with the above listed uprated components. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 04

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Compressor MMP- 4 and Contactor M- 4, Continued MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- 4 & M- 4 Link Detail 40C Circuit #- 08/ 40C Circuit #, 50C- 08/30/ MMP- 4 & M- 4 Link Detail 40C Circuit #- 460/ 40C Circuit #, 50C- Unit Size 40 50 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor 50A 349937 4 4 4 4 Contactor 7 80A 349936 4 Contactor 7 65A 3499353 4 4 4 M3, 4 Contactor 50A 349937 4 4 4 4 Contactor 7 80A 349936 4 4 Contactor 65A 3499353 4 4 Compressor MMP s & Parts 3 MMP- Motor Protector 90-50A 349938607 4 4 4 4 Motor Protector 7 60-00A 349938606 4 Motor Protector 7 50-65A 34993449 4 4 Motor Protector 40-50A 34993448 4 MMP3, 4 Motor Protector 90-50A 349938607 4 4 4 4 Motor Protector 7 60-00A 349938606 4 4 Motor Protector 50-65A 34993449 4 4 3E Aux. Contact- NO or NC 7 34993870 4 4 4 4 4 4 4 Front Mounted Contact- NO 7 3499338 4 3 4 4 3G Lug Kit (3 lugs per kit) 7 34993880 4 6 4 6 8 5 4 4 4 The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage 7 7 combination. For unit size 40C, M, & MMP, are for the 30HP compressors; M3, 4 & MMP3, 4 are for the 35HP compressors. 3 Used on Circuit # only. 4 Used on Circuit # only. 5 Used on Circuit # only and does NOT require 3 field supplied ring terminals 6 Also requires 3 field supplied ring terminals. 7 On 7/09 the amp ratings for Compressor Contactors and Motor Protectors were revised. When replacing an original Contactor OR MMP, it is recommended that the Contactor and MMP be replaced with the above listed uprated components. For 35 and 40HP compressors, in addition to the Contactor and MMP, the Auxiliary and Lug Kit MUST also be ordered. Refer to the Compressor listing in Section M to determine Compressor horsepower. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 05

Section N- Controls MicroTech II: Code = *D, *S- /07 thru /0 Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB MMP 3 3B Link Circuit Breaker 5 4 Spacer Contactor Unit Size 076-00 0-50 Ref. Sch. Part Part No. Sym. Description Number Fan Contactors M, Contactor- Condenser Fan 9A 3499340 M3, 3 Contactor- Condenser Fan 9A 3499340 Fan MMP s & Parts 3 MMP, Manual Motor Protector 4.0-6.3A 349934049 Manual Motor Protector.5-4.0A 3000434 Manual Motor Protector.6-.5A 349934047 MMP, Manual Motor Protector 4.0-6.3A 349934049 Manual Motor Protector.5-4.0A 3000434 Manual Motor Protector.6-.5A 349934047 MMP3, 3 Manual Motor Protector 4.0-6.3A 349934049 Manual Motor Protector.5-4.0A 3000434 Manual Motor Protector.6-.5A 349934047 3B Link- MMP 349939 4 4 4 6 6 6 4 Spacer- Contactor 34990650 4 4 4 6 6 6 Fan Circuit Breaker 5 CB Circuit Breaker- Condenser Fan 3499396 The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. 08/ 08/ RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 06

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Diagram COM MCB Deadfront Door (Closed view) The above diagrams show a typical two compressor (size 076-00C) Main Control Box layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 07

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Control Box Component Label Diagram Note that all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 08

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components Sch. Part Part Qty. Sym. Description Number Main Controller MCB Main Controller w/ HMI Display 9340730 Terminal Block, MCB- Pole 934030 Terminal Block, MCB- 3 Pole 9340303 6 Terminal Block, MCB- 5 Pole 9340305 Terminal Block, MCB- 6 Pole 9340306 Terminal Block, MCB- 7 Pole 9340307 Terminal Block, MCB- 8 Pole 9340308 Expansion Module EXPA- D Expansion Module 9340750 Board to Board Connector, 4 Pin 3 9340970 /board Terminal Block, Board to Wire Connector EXP- Pole 3 934030 /board Terminal Block, Board to Wire Connector EXP- 3 Pole 3 9340303 /board Terminal Block, Board to Wire Connector EXP- 7 Pole 3 9340307 /board Terminal Block, Board to Wire Connector EXP- 8 Pole 3 9340308 /board Communication Card COM Bacnet- MSTP (Code = BE, BF, BW) 0900670 Bacnet- IP (Code = EE, EF, EW) 09006709 LonWorks- Discharge (Code = LE, LW) 090067 LonWorks- Constant Volume (Code = LF) 090067 Resistors 4 RES Resistor- Refrigeration Circuit # 500 OHM 0446905 RES Resistor- Refrigeration Circuit # 000 OHM 0446900 RES3 Resistor- Freezestat (FS) 000 OHM 0446900 RES4 Resistor- OAE 500 OHM 0446905 RES6-8 Resistor- SPS, SPS, SPS3 500 OHM 04469046 /switch Switches- Control HS Switch- Electric Heat Shutdown (Code 04= E) 80005045 S Switch- System On/Off Gas Heat Units with no UV Lights DPST/5A 08446400 Gas Heat Units with UV Lights 4PST/30A 033536700 Electric, Steam, HW, No Heat with no UV Lights SPST/0A 80005045 Electric, Steam, HW, No Heat with UV Lights DPST/5A 08446400 S4 Switch- Inverter Bypass On/Off DPST/5A 08798400 S7 Switch- Local On/Auto/Off to Controller SPDT/5A 9340 Transformers T Transformer- Control 0-4V 3000436 T3 Transformer- Control 0-4V 3000436 Duct Hi Limit and Static Pressure Sensors DHL Duct Hi Limit Switch 06549380 SPS, Pressure Transducer Kit- Duct Sensor (9/ & Earlier) 5, 6 90458 Pressure Transducer- Duct Sensor (0/ thru 5/3) 5 90746 Pressure Transducer Kit- Space Sensor (9/ & Earlier) 5, 6 90459 Pressure Transducer- Space Sensor (0/ thru 5/3) 5 907463 The Main Controller must be programmed in order to function correctly. When ordering a replacement MCB, provide the unit model and serial number so the unit specific software code can be loaded before shipment. Quantity varies depending upon unit options selected. 3 This part does NOT come with the Expansion Module; order separately if needed. 4 Not Shown on diagram. 5 SPS Duct Sensor Code 3=,, 3. SPS Duct Sensor Code 3=. SPS Space Sensor Code 3= 3, 4. 6 As of 09/ the original Pressure Transducer is no longer available. The Transducer Kit includes Transducer, Dinrail, Resistor, Sampling Tube, and Installation Instructions. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 09

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Qty. Sym. Description Number Relays R Relay- Condenser Fan 34993474 R3 Relay- Condenser Fan 3 34993474 R4 Relay- Condenser Fan 3 34993474 R0 Relay- Heat 34993474 R5 Relay- Gas Heat, Start Supply Fan Inverter 3 (Code 4=,,3,5,6,7) 34993474 R6 Relay- Isolation Damper- Open/Close 3 3499347 R8 Relay- Isolation Damper Safety 3499347 R63 Relay- Duct Hi Limit Units with Supply Fan Inverter Code 4=, 3, 6 0 OR Duct Sensor Code 3= Y, 34993494 Duct & Space Sensor OR Space Sensor Code 3= 3, 4 34993493 DHL Sensor Code 3= 5 3499349 Units with Return Fan Inverter Code 4= 4, 8, 9 Space Sensor Code 3= 4 34993493 Units with Supply & Return Fan Inverters Code 4=, 5, 7 Vars. Code 3=,, 3, 4, Y 34993473 R64 Relay- Sump Pump 34993474 Time Delays TD3 Time Delay- Hi Pressure 3 5 Sec. 05670 TD4 Time Delay- Hi Pressure 3 5 Sec. 05670 TD0 Time Delay- Return Air Fan 08006 Terminal Block TB Terminal Block 34993064 Phase Voltage Monitor 3 PVM Phase Voltage Monitor 08/30/ 000 Phase Voltage Monitor 000 Sensors/Switches ZNT Sensor- Zone Temperature w/ Tenant Override 3 3770 Sensor- Zone Temp. w/ Tenant Override & Remote Setpoint Adj., 3 3780 DAT Sensor- Discharge Air Temperature 3 934460 EFT Sensor- Entering Air Temperature 3 934460 OAT Sensor- Outside Air Temperature 3 934460 RAT Sensor- Return Air Temperature 3 934460 EAT Sensor- Exhaust Air Temperature 3 934460 LAT Sensor- Leaving Air Temperature 3 934460 Remote Display KEYPAD Remote Interface Display 4 9340800 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930647. SCC Units only- Code = BF, LF, EF, SF. 3 Not Shown on diagram. 4 Used with Controller (MCB) w/o Display (HMI) p/n: 934070. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 0

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Transformer- Main T Transformer- Main Control Electric, Hydronic, No Heat (Code 04= E, S, W, Y) Units without UV Lights 03853975 Units without UV Lights 03853957 Units without UV Lights 03853984 Units with UV Lights (Code 7 [Digit ]= - 8) 03853976 Units with UV Lights (Code 7 [Digit ]= - 8) 03853958 Units with UV Lights (Code 7 [Digit ]= - 8) 03853985 Gas Heat Code 04= A Units without UV Lights 03853976 Units without UV Lights 03853958 Units without UV Lights 03853985 Units with UV Lights (Code 7 [Digit ]= - 8) 34993989 Units with UV Lights (Code 7 [Digit ]= - 8) 349939809 Units with UV Lights (Code 7 [Digit ]= - 8) 34993989 Fuses- T FA,B Fuse- T Transformer, Primary Electric, Hydronic, No Heat (Code 04= E,S,W,Y) Units without UV Lights 34993734 Units without UV Lights 34993733 Units without UV Lights 34993730 Units without UV Lights 3499375 Units with UV Lights (Code 7 [Digit ]= - 8) 34993735 Units with UV Lights (Code 7 [Digit ]= - 8) 3499373 Units with UV Lights (Code 7 [Digit ]= - 8) 3499379 Gas Heat (Code 04= A) Units without UV Lights 34993735 Units without UV Lights 3499373 Units without UV Lights 3499379 Units with UV Lights (Code 7 [Digit ]= - 8) 34993737 3 3 Units with UV Lights (Code 7 [Digit ]= - 8) 34993733 3 Units with UV Lights (Code 7 [Digit ]= - 8) 3499373 3 FC Fuse- T Transformer, Secondary 349937038 Fuse- T Transformer, Secondary 349937036 Fuse- T Transformer, Secondary 349937035 Water Pump/Sump Heater Components M64 Contactor- Water Pump 9A 34993 MMP64 Motor Protector- Water Pump 4-5.9A 349934049 Motor Protector- Water Pump.5-3.9A 349934048 Motor Protector- Water Pump.6-.4A 349934047 - Spacer 34990650 - Link 349939 M65 Contactor- Sump Heater 5A 349933 Contactor- Sump Heater 8A 349933 Contactor- Sump Heater 9A 34993 FB65 Fuse Block- Sump Heater 03780 Fuse 5A 34993736 Fuse 0A 34993735 Fuse A 3499373 Fuse 0A 3499373 Fuse Guard 3499387 T Transformers also use Cover kit p/n 34995590 & Fuse Puller kit p/n 34995580 (not used on Transformer p/ns 34993989, 349939809, 34993989). Fuse depends on heat type and presence of UV lights. 349937038= Gas Heat Unit w/uv lights; 349937036= Gas Heat Unit with no UV lights OR Non-Gas Heat Unit with UV lights; 349937035= Non- Gas Heat Units with no UV lights. 3 Fuses used on Gas Heat Unit w/uv lights also use Fuse Block p/n 037803 & 3 Pullers p/n 3499387. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Terminal Blocks TB, 7 Terminal Block 34993064 TB3, 4 Terminal Block 34993064 Fuses F, F3, F5 Fuses 4 Fuse Block 037803 /fuse /fuse /fuse /fuse Fuse Cover 3499387 /fuse /fuse /fuse /fuse F Fuse- 000+VA Transformer 4 349937035 F3 Fuse- Blower Motor 4 00-500 mbh furnace 349937035 F3 Fuse- Blower Motor 4 000 mbh furnace 349937036 F5 Fuse- UV Lights 4 (Code 7 [Digit ]= - 8) 34993703 F- 3 Fuse Blocks- Condenser Fan 0378033 /fan /fan /fan /fan Fuse- Condenser Fan 0475309 /fan /fan /fan /fan Fuse Cover/Puller- Condenser Fan 3499387 /fuse /fuse /fuse /fuse Power Blocks PB, PB Power Block- Main 4 (Code = P, Q) Power Block, Non- Electric Heat Units- 75A 3 03037776 Power Block, Electric Heat Units- 75A 3 03037780 Lug- 75A Block 34993800 Power Block, Non- Electric Heat Units- 55A 3 03037778 Lug- 55A Block 34993800 Power Block, Non- Electric Heat Units- 380A 3 03037779 Power Block, Electric Heat- 380A 3 0303778 Lug- 380A Block 34993800 Power Block, Non- Electric Heat Units- 60A 3 0303770 Cover- 60A Block 349938345 3 3 3 3 Lug- 60A Block 34993800 Power Block, Non- Electric Heat Units- 760A 3 03037760 Power Block, Electric Heat Units, 08/- 760A 3 0303777 Power Block, Electric Heat Units, 460/- 760A 3 03037760 Cover- 760A Block 349938345 3 3 3 3 Lug- 760A Block 349938003 Power Block, Non- Electric Heat Units- 840A 3 0303774 Cover- 840A Block 349938345 3 3 3 3 Lug- 840A Block 349938003 PB Power Block- Power Distribution 3 Power Block- 40A 03037785 Power Block- 760A 030377 Cover- 760A Block 349938345 Varies depending on unit options. Part number is for one individual section. Ground Block is p/n 349930647. Varies depending on unit options. Part number is for one individual section. When required, Jumpers are p/n 3499309 ( pole), 34993093 (3 pole), 34993094 (4 pole), 34993095 (5 pole). 3 Any of the listed parts may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. PB is installed when Code = Q. 4 Not shown on diagram. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Power Blocks, continued 4 PB Power Block- Power Distribution (Code 04= E) 0, 40 KW Electric Heat 03037777 60, 80, 00, 0 KW Electric Heat 03037785 60, 80, 00, 0 KW Electric Heat 03037777 60, 00, 40, 80, 30 KW Electric Heat 03037785 PB0 Power Block- Supply Fan (Code 5= F) 03037776 PB0 Power Block- Return Fan (Code 5= F) 03037776 Receptacles 4 REC Receptacle 039003600 Disconnect Switches 4 DS Disconnect Switch- Main Gas, Steam, HW, No Heat (Code 04= A, S, W, Y) Switch- 00A 3499355 Handle Kit 3499355 Shaft 3499604 Ground Lug 34993800 Switch- 50A 3499356 Handle Kit (with operating mechanism) 34993553 Shaft 3499605 Ground Lug 34993800 Switch- 50A 3499356 Handle Kit (with operating mechanism) 34993553 Shaft 3499605 Ground Lug 34993800 Switch- 400A 34993535 Handle Kit (with operating mechanism) 3499356 Shaft 3499606 Ground Lug 34993800 Switch- 600A,, 3 9343805 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 3499607 Ground Lug 34993800 Switch- 800A, 3 934380 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 349964 Ground Lug 349938003 Switch- 000A, 3 9343806 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 349964 Ground Lug 349938003 Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. The 600A switch listed is used on units with one Disconnect or two Disconnects EH/balance of unit (Code = A, B). If unit has two Disconnects where the second Disconnect controls the fans (Code = C) or 3 Disconnects (Code = D) then use Switch p/n 9343800, Handle kit p/n 9343790, Shaft p/n 3499633, and Ground Lug p/n 34993800. 3 Note that the original Disconnect is obsolete. If replacing an original part, due to dimensional differences, minor field modifications may be required for proper installation. 4 Not shown on diagram. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Disconnect Switches, continued DS Disconnect Switch- Main Electric Heat (Code 04= E) units Switch- 00A 349935 Handle Kit 3499355 Shaft 3499604 Ground Lug 34993800 Load Lug 3499560 Cover- Load Lug 349957003 Switch- 50A 349935 Handle Kit 34993553 Shaft 3499605 Ground Lug 34993800 Load Lug 3499560 Cover- Load Lug 34995700 Switch- 50A 349935 Handle Kit 34993553 Shaft 3499605 Ground Lug 34993800 Load Lug 34995630 Cover- Load Lug 34995700 Switch- 400A 34993535 Handle Kit 3499356 Shaft 3499606 Ground Lug 34993800 Switch- 600A,, 3 9343805 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 3499607 Ground Lug 34993800 Switch- 800A, 3 934380 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 349964 Ground Lug 349938003 Switch- 000A, 3 9343806 Handle 349960 Operating Mechanism 3 9345500 Shaft 3499630 Shaft- Mod 3 349964 Ground Lug 349938003 Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. The 600A Switch listed is used on units with one Disconnect or two Disconnects EH/balance of unit (Code = A, B). If unit has two Disconnects where the second Disconnect controls the fans (Code = C) or 3 Disconnects (Code = D) then use Switch p/n 9343800, Handle kit p/n 9343790, Shaft p/n 3499633, and Ground Lug p/n 34993800. 3 Note that the original Disconnect is obsolete. If replacing an original part, due to dimensional differences, minor field modifications may be required for proper installation. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Main Control Box Common Components, Continued Sch. Part Part Voltage Sym. Description Number Disconnect Switches, continued DS Disconnect Switch- SAF/RAF (Code = C, D) Switch- 00A 349935 Handle Kit 3499355 Shaft 3499604 Ground Lug 34993800 Load Lug 3499560 Cover- Load Lug 349957003 Switch- 50A 349935 Handle Kit 34993553 Shaft 3499605 Ground Lug 34993800 Load Lug 3499560 Cover- Load Lug 34995700 Switch- 50A 349935 Handle Kit 34993553 Shaft 3499605 Ground Lug 34993800 Load Lug 34995630 Cover- Load Lug 34995700 Switch- 400A 3499353 Handle Kit 3499356 Shaft 3499606 Ground Lug 34993800 Load Lug 34995640 3 3 3 3 Cover- Load Lug 349957004 Any of the listed Disconnects may be used, depending on unit options. Check installed part to verify, or contact Daikin Applied with unit serial and GO number to ensure correct replacement is selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Sch. Part Part Voltage Sym. Description Number Circuit Breakers- Supply & Return Fan CB0 CB0 Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply Fan CB0, and Return Fan CB0 Circuit Breaker Circuit Breaker- Supply Fan Circuit Breaker- Return Fan Motor HP= 5, 7.5, 0 34993960 Motor HP= 5 3499396 Motor HP= 5, 7.5 3499396 Motor HP= 7.5 34993964 Motor HP= 0 34993966 Motor HP= 0 3499396 Motor HP= 5 34993969 Motor HP= 5 34993964 Motor HP= 5, 0 349939604 Motor HP= 0 34993963 Motor HP= 0 349939630 Motor HP= 0, 5 34993966 Motor HP= 5 34993963 Motor HP= 5 34993963 Motor HP= 5, 30 349939606 Motor HP= 30 34993970 Motor HP= 30 349939633 Motor HP= 30 34993968 Motor HP= 40 349939703 Motor HP= 40 349939630 Motor HP= 40 349939608 Motor HP= 50 34993963 Motor HP= 50 34993960 Motor HP= 60 34993963 Motor HP= 60 3499396 Motor HP= 75 34993970 Plugs 4 Pin Plug 3499300 varies varies varies varies 3 6 Pin Plug 349930403 varies varies varies varies 4 Pin Plug 349930405 varies varies varies varies 5 3 Pin Cap Kit 34993050 varies varies varies varies 6 6 Pin Cap Kit 349930503 varies varies varies varies 7 9 Pin Cap Kit 349930504 varies varies varies varies 8 5 Pin Cap Kit 349930506 varies varies varies varies All possible Plugs used are listed. Check installed part to verify. Not shown on diagram. Used for PL, PL,, PL3, PL4, PL5, PL6, PL,PL3, PL4, PL37, PL38. 3 Used with Strain Relief (p/n 3000473) & 6 Pin Cap Kit (p/n 349930503). Used for PL0, PL. 4 Used for PL, PL, PL5, PL6, PL7, PL8, PL9, PL30 (PL & also use Strain Relief p/n 3000475 & Cap Kit p/n 349930505). 5 Used for PL6, PL7, PL3, PL3, PL33, PL34, PL39, PL40, PL4, PL4. 6 Used for PL9, PL0. 7 Used for PL8, PL9, PL35, PL36, PL43. 8 Used for PL7, PL8. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Diagrams Front Mtd. Contact 3E Aux. Contact Line Shield 3D 3A 3 MMP Front Mounted Contact 3E Link 3B 4 Spacer MMP 3 Contactor Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 3-0 HP Motors- All Voltages 5, 0 HP Motor- 460/ 5, 30 HP Motors- MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5, 0 HP Motors- 08/ 5 HP Motors- 30/ 30 HP Motors- 40 HP Motors- 460/ 50 HP Motors- 460/ 60HP Motors- MMP 3 Lug 3G 3G 3 Lug MMP Trip Indicator Alarm 3F 3F Trip Ind. Interlock 3G Lug Contactor Contactor MMP0 & M0 Link Detail MMP0 & M0 Link Detail 5 HP Motors- 30, 40 HP Motors- 08/ 50 HP Motor- 60HP Motors- 75 HP Motors- 460/ MMP0 & M0 Link Detail 50HP Motors- 60HP Motors- 08/ The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components 3 HP Motor- Code = H** Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Return Fan 34993 Contactor- Return Fan 34993 3 MMP0 MMP- Return Fan 349934050 MMP- Return Fan 349934049 MMP- Return Fan 349934048 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 5 HP Motor- Code OR 3= J** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 34993 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993405 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993405 MMP- Supply (MMP0) OR Return (MMP0) Fan 349934050 MMP- Supply (MMP0) OR Return (MMP0) Fan 349934049 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 7.5 HP Motor- Code OR 3= K** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 34993 Contactor- Supply (M0) OR Return (M0) Fan 34993 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 349934053 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993405 MMP- Supply (MMP0) OR Return (MMP0) Fan 349934050 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 0 HP Motor- Code OR 3= L** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 34993 3 MMP0, 0 MMP- Supply (MMP0) OR Return (MMP0) Fan 349934055 MMP- Supply (MMP0) OR Return (MMP0) Fan 34993405 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 5 HP Motor- Code OR 3= M** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349935 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 349933 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 34993448 MMP- Supply (M0) OR Return (M0) Fan 34993447 MMP- Supply (M0) OR Return (M0) Fan 349934053 MMP- Supply (M0) OR Return (M0) Fan 34993405 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 0 HP Motor- Code OR 3= N** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499353 Contactor- Supply (M0) OR Return (M0) Fan 349933 Contactor- Supply (M0) OR Return (M0) Fan 349933 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 34993449 MMP- Supply (M0) OR Return (M0) Fan 34993448 MMP- Supply (M0) OR Return (M0) Fan 349934054 MMP- Supply (M0) OR Return (M0) Fan 349934053 3B Link 349939 3E Aux. Contact- NO OR NC 3499338 4 Spacer 34990650 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 9

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 5 HP Motor- Code OR 3= P** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349936 Contactor- Supply (M0) OR Return (M0) Fan 349935 Contactor- Supply (M0) OR Return (M0) Fan 349933 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938606 MMP- Supply (M0) OR Return (M0) Fan 34993449 MMP- Supply (M0) OR Return (M0) Fan 349934055 MMP- Supply (M0) OR Return (M0) Fan 349934054 3B Link 349939 3E Aux. Contact- NO or NC 3499338 3F Trip Indicator Alarm 34993870 3G Lug (3 per kit) 34993880 30 HP Motor- Code OR 3= Q** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349937 Contactor- Supply (M0) OR Return (M0) Fan 349936 Contactor- Supply (M0) OR Return (M0) Fan 349935 Contactor- Supply (M0) OR Return (M0) Fan 349933 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938606 MMP- Supply (M0) OR Return (M0) Fan 34993447 MMP- Supply (M0) OR Return (M0) Fan 349934055 3B Link 349939 3E Aux. Contact- NO or NC 3499338 3F Trip Indicator Alarm 34993870 3G Lug (3 per kit) 34993880 4 Spacer 34990650 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 0

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 40 HP Motor- Code OR 3= R** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 349937 Contactor- Supply (M0) OR Return (M0) Fan 349937 Contactor- Supply (M0) OR Return (M0) Fan 349935 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938607 MMP- Supply (M0) OR Return (M0) Fan 349938606 MMP- Supply (M0) OR Return (M0) Fan 34993448 MMP- Supply (M0) OR Return (M0) Fan 34993447 3E Aux. Contact- NO or NC 3499338 3F Trip Indicator Alarm 34993870 3G Lug (3 per kit) 34993880 Also requires 3 field supplied ring terminals. 50 HP Motor- Code OR 3= S** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499370 Contactor- Supply (M0) OR Return (M0) Fan 349937 Contactor- Supply (M0) OR Return (M0) Fan 349936 Contactor- Supply (M0) OR Return (M0) Fan 3499353 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938607 MMP- Supply (M0) OR Return (M0) Fan 34993449 3E MMP- Supply (M0) OR Return (M0) Fan 34993448 3E Aux. Contact- NO or NC 3499338 3F Trip Indicator Alarm 34993870 3G Lug (3 per kit) 34993880 Also requires 3 field supplied ring terminals. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Supply MMP0 Motor Protector, M0 Fan Contactor & Return MMP0 Motor Protector, M0 Fan Contactor Components, Continued 60 HP Motor- Code OR 3= T** Voltage Ref. Sch. Part Part No. Sym. Description Number M0, 0 Contactor- Supply (M0) OR Return (M0) Fan 3499370 Contactor- Supply (M0) OR Return (M0) Fan 349936 3 MMP0, 0 MMP- Supply (M0) OR Return (M0) Fan 349938608 MMP- Supply (M0) OR Return (M0) Fan 349938607 MMP- Supply (M0) OR Return (M0) Fan 349938606 MMP- Supply (M0) OR Return (M0) Fan 34993449 3E Aux. Contact- NO or NC 3499338 3F Trip Indicator Alarm 34993870 3G Lug (3 per kit) 34993880 Lug (3 per kit) 34993880 Also requires 3 field supplied ring terminals PER kit. 75 HP Motor- Code 3= U** Voltage Ref. Sch. Part Part No. Sym. Description Number M0 Contactor- Supply Fan 349937 3 MMP0 MMP- Supply Fan 349938606 3F Trip Indicator Alarm 34993870 3G Lug 34993880 RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Compressor MMP- 4 and Contactor M- 4 MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- & M- Link Detail 076C- 08/ 089C, 00C- 08/30/ MMP- & M- Link Detail 076C- 460/ 089C, 00C- Unit Size 076 089 00 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor 3 3 3 Contactor 50A 349937 Contactor 5A 349937 Contactor 80A 349936 Contactor 65A 3499353 Compressor MMP s & Parts 3 MMP, Manual Motor Protector 50-0A 349938608 Manual Motor Protector 90-50A 349938607 Manual Motor Protector 60-00A 349938606 Manual Motor Protector 50-65A 34993449 Manual Motor Protector 40-50A 34993448 3E Aux. Contact- NO or NC 34993870 Front Mounted Contact- NO 3499338 3G Lug Kit (3 lugs per kit) 34993880 The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. 3 Contact Daikin Applied with model and serial number information so that the correct part(s) can be identified. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 3

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Compressor MMP- 4 and Contactor M- 4, Continued MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- 4 & M- 4 Link Detail 0C, 30C- 08/ MMP- 4 & M- 4 Link Detail 0C, 30C- 460/ Unit Size 0 30 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M- 4 Contactor 50A 349937 4 4 Contactor 5A 349937 4 4 Contactor 65A 3499353 4 4 Contactor 50A 349935 4 4 Compressor MMP s & Parts 3 MMP- 4 Manual Motor Protector 90-50A 349938607 4 4 4 Manual Motor Protector 60-00A 349938606 4 Manual Motor Protector 50-65A 34993449 4 Manual Motor Protector 40-50A 34993448 4 4 Manual Motor Protector 30-40A 34993447 4 3E Aux. Contact- NO or NC 34993870 4 4 Front Mounted Contact- NO 3499338 4 4 4 4 3G Lug Kit (3 lugs per kit) 34993880 4 4 4 4 The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 4

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Compressor MMP- 4 and Contactor M- 4, Continued MMP 3 3G Lug Aux. Contact 3E Front Mounted Contact 3E Contactor MMP 3 Contactor MMP- 4 & M- 4 Link Detail 40C Circuit #- 08/ 40C Circuit #, 50C- 08/30/ MMP- 4 & M- 4 Link Detail 40C Circuit #- 460/ 40C Circuit #, 50C- Unit Size 40 50 Ref. Sch. Part Part No. Sym. Description Number Compressor Contactors & Parts M, Contactor 50A 349937 4 4 4 4 Contactor 80A 349936 4 Contactor 65A 3499353 4 4 4 M3, 4 Contactor 50A 349937 4 4 4 4 Contactor 80A 349936 4 4 Contactor 65A 3499353 4 4 Compressor MMP s & Parts 3 MMP- Manual Motor Protector 90-50A 349938607 4 4 4 4 Manual Motor Protector 60-00A 349938606 4 Manual Motor Protector 50-65A 34993449 4 4 Manual Motor Protector 40-50A 34993448 4 MMP3, 4 Manual Motor Protector 90-50A 349938607 4 4 4 4 Manual Motor Protector 60-00A 349938606 4 4 Manual Motor Protector 50-65A 34993449 4 4 3E Aux. Contact- NO or NC 34993870 4 4 4 4 4 4 4 Front Mounted Contact- NO 3499338 4 3 4 4 3G Lug Kit (3 lugs per kit) 34993880 4 6 4 6 8 5 4 4 4 The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. For unit size 40C, M, & MMP, are for the 30HP compressors; M3, 4 & MMP3, 4 are for the 35HP compressors. 3 Used on Circuit # only. 4 Used on Circuit # only. 5 Used on Circuit # only and does NOT require 3 field supplied ring terminals 6 Also requires 3 field supplied ring terminals RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 5

Section N- Controls MicroTech III: Code = *E, *F, *W- / thru 5/3 Condenser Fan Motor Protector MMP- 3, Contactors M- 3 & Circuit Breaker CB MMP 3 3B Link Circuit Breaker 5 4 Spacer Contactor Unit Size 076-00 0-50 Ref. Sch. Part Part No. Sym. Description Number Fan Contactors M, Contactor- Condenser Fan 9A 3499340 M3, 3 Contactor- Condenser Fan 9A 3499340 Fan MMP s & Parts 3 MMP, Manual Motor Protector 4.0-6.3A 349934049 Manual Motor Protector.5-4.0A 3000434 Manual Motor Protector.6-.5A 349934047 MMP, Manual Motor Protector 4.0-6.3A 349934049 Manual Motor Protector.5-4.0A 3000434 Manual Motor Protector.6-.5A 349934047 MMP3, 3 Manual Motor Protector 4.0-6.3A 349934049 Manual Motor Protector.5-4.0A 3000434 Manual Motor Protector.6-.5A 349934047 3B Link- MMP 349939 4 4 4 4 Spacer- Contactor 34990650 4 4 4 6 6 6 Fan Circuit Breaker 5 CB Circuit Breaker- Condenser Fan 3499396 The above diagrams show ALL possible parts. Not every part shown applies to every unit size/voltage combination. Also requires 3 field supplied ring terminals. 08/ 08/ RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 6

Section N- Controls MicroTech III: Code = *E, *F, *W- 6/3 & Later Main Control Box Diagram COM MCB Deadfront Door (Closed view) The above diagrams show a typical two compressor (size 076-00C) Main Control Box layout and is to be used for reference only. Specific unit components, component quantity, and component layout may differ depending upon unit size and options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 7

Section N- Controls MicroTech III: Code = *E, *F, *W- 6/3 & Later Control Box Component Label Diagram GOI Number: H090030000R0 MB= Main Box; BB= Bypass Box; EB= Electric Heat Box; GB= Gas Box; PB= Prop Exhaust Box; Location Device ID McQuay Part # Description BB FB0 34996453 Fuse Holder, 3 Pole, 00A, 600V, Cl BB FB0 934037 Fuse 00A 600V Class J Fast Acti BB FB0 34996463 Cover, Fuse Holder, 3 Pole, 00A, C BB FB0 93403 Fuse 50A 600V Class J Fast Actin BB M30I 9353950 Contactor IEC Reversing 40A 0VAC BB M30I 935480 Contactor Auxiliary Contact NO NC BB M30I 9354740 MMP to Contactor Link Module Size S BB M40I 93539304 Contactor IEC Reversing 5A 0VAC BB M40I 9354600 MMP to Contactor Link Module Screw BB M40I 9354580 MMP to Contactor Spacer Size S0 BB M40I 34993906 SCREW, PANHEAD B-type, #8 X " BB MMP30 93543305 MMP Class 0 Size S 8 to 40A BB MMP30 935460 MMP Auxiliary Contact Sizes S and BB MMP40 9354300 MMP Class 0 Size S0 4 to 0A Scre BB MMP40 9354380 MMP Auxiliary Contact Sizes S00 and BB MMP40 9354550 MMP Type E Phase Barrier Sizes S00 GB AS 033003800 Ctrl-press air switch gas burner GB AS 0679770 Conduit fitting nipple - 3-4 GB FLC 9343703 Control Temp Fan Limit Gas Heat GB FSG 07330070 Ctrl-temp flame safegrd base GB FSG 073300803 Ctrl-temp Flame Safegrd Control GB FSG 07330090 Ctrl-temp flame safegrd amplifier GB FSG 0733000 Ctrl-temp flame safegrd timer 90 GB IT 03448600 Transformer Ignition GB LS 05997530 Limit switch GB LS 05997530 Limit switch GB R0A 349934764 DPDT Relay 5A 0VAC GB R0A 34996470 Mounting Adapter P Relay to Dinra GB S3 033536700 Switch Toggle 4PST 5V MB BNMS 9340830 Communication Card, BACnet-MSTP, MT MB DS 935850 Circuit Breaker Molded Case Switch MB DS 935560 lug kit, 3 pcs with power control t MB DS 934040 Connector -4 quick connect tab MB DS 9355330 lug kit, 3 pcs, T3 Frame, 5A MB DS 34993905 SCREW, PANHEAD AB-type, #8-8 X 3" MB DS 9355080 Circuit Breaker Operating Mechanism MB DS 9340 HANDLE, PISTOL, ABB DISCONNECT, RED MB DS6 9344380 Fuse holder, Circuit Protector, P MB DS6 3499373 Fuse 0A Rejection Type MB EXP-B 9340750 Extension I-O 5 Points MB EXP-B 9340970 Connector for extension I-O - Direc MB EXP-C 9340750 Extension I-O 5 Points MB EXP-C 9340970 Connector for extension I-O - Direc MB F 34993707 Fuse A Midget Non-Rejection Typ MB FS 0994886 Fuse, 5A 600V Class CC Type T Fast MB F 34993707 Fuse A Midget Non-Rejection Typ MB FA 3499373 Fuse 0A Rejection Type MB FB 3499373 Fuse 0A Rejection Type MB FC 349937036 Fuse 0A Midget Non-Rejection Ty MB F 349937035 Fuse 5A Midget Non-Rejection Ty MB F 34993707 Fuse A Midget Non-Rejection Typ MB F 34993707 Fuse A Midget Non-Rejection Typ MB F3 349937035 Fuse 5A Midget Non-Rejection Ty MB F6C 349937036 Fuse 0A Midget Non-Rejection Ty MB FB65 3499373 Fuse A Rejection Type MB GRD 349930647 Terminal x spring Green row MB KEYPAD 9340800 REMOTE HMI, PANEL MOUNT MB M 935970 Contactor IEC 80A 0VAC Coil Screw MB M 935470 Contactor Auxiliary Contact NO NC MB M 9354750 MMP to Contactor Link Module Size S MB M 9353405 Contactor IEC 7A 0VAC Coil Spring MB M 93540 Contactor Auxiliary Contact NO NC MB M 9353405 Contactor IEC 7A 0VAC Coil Spring MB M 9354590 MMP to Contactor Link Module Screw MB M 93540 Contactor Auxiliary Contact NO NC MB M 935970 Contactor IEC 80A 0VAC Coil Screw MB M 935470 Contactor Auxiliary Contact NO NC MB M 9354750 MMP to Contactor Link Module Size S MB M 9353405 Contactor IEC 7A 0VAC Coil Spring MB M 93540 Contactor Auxiliary Contact NO NC MB M 9353405 Contactor IEC 7A 0VAC Coil Spring MB M 9354590 MMP to Contactor Link Module Screw MB M 93540 Contactor Auxiliary Contact NO NC MB M64 9353405 Contactor IEC 7A 0VAC Coil Spring MB M64 9354590 MMP to Contactor Link Module Screw MB M65 9353405 Contactor IEC 7A 0VAC Coil Spring MB MCB 934070 Base Controller with IP MB MMP 93543404 MMP Class 0 Size S3 57 to 75A MB MMP 935460 MMP Auxiliary Contact Sizes S and MB MMP 9354908 MMP Class 0 Size S00. to 3.A S MB MMP 9354380 MMP Auxiliary Contact Sizes S00 and MB MMP 9354550 MMP Type E Phase Barrier Sizes S00 MB MMP 93543404 MMP Class 0 Size S3 57 to 75A MB MMP 935460 MMP Auxiliary Contact Sizes S and MB MMP 9354908 MMP Class 0 Size S00. to 3.A S MB MMP 9354380 MMP Auxiliary Contact Sizes S00 and MB MMP 9354550 MMP Type E Phase Barrier Sizes S00 MB MMP64 9354908 MMP Class 0 Size S00. to 3.A S MB MMP64 9354550 MMP Type E Phase Barrier Sizes S00 MB OAER 3499347 DPDT Relay 0A 4VAC MB OAER 3499348 Relay Socket DPDT MB OL 93547906 Overload Relay Class 0 Size S00. MB OL 93547906 Overload Relay Class 0 Size S00. MB PB 03037785 Distribution Power Terminal Brd 4 MB PS 00355000 Switch Toggle SPST-0A 5va MB PS 00355000 Switch Toggle SPST-0A 5va MB PVM 000 3PH Monitor 90-480VAC MB R 34993474 DPDT Relay 0A 0VAC MB R 3499348 Relay Socket DPDT MB R 34993474 DPDT Relay 0A 0VAC MB R 3499348 Relay Socket DPDT MB R4 34993474 DPDT Relay 0A 0VAC MB R4 3499348 Relay Socket DPDT MB R5 34993474 DPDT Relay 0A 0VAC MB R5 3499348 Relay Socket DPDT MB R56 34993474 DPDT Relay 0A 0VAC MB R56 3499348 Relay Socket DPDT MB R57 34993474 DPDT Relay 0A 0VAC MB R57 3499348 Relay Socket DPDT MB R63 34993493 3PDT Relay 0A 0VAC MB R63 3499350 Relay Socket 3PDT MB R64 34993474 DPDT Relay 0A 0VAC MB R64 3499348 Relay Socket DPDT MB R66 34993473 DPDT Relay 0A 4VDC MB R66 3499348 Relay Socket DPDT MB RES4 0446905 RESISTOR 500 Ohm -8 Watt % Pr MB S 08446400 Switch Toggle DPST 5V MB S4 00355000 Switch Toggle SPST-0A 5va MB S4 08798400 Switch Toggle 3position ON-OFF-O MB S7 9340 Switch Toggle position ON-ON S MB SPS 90746 SENSOR, AIR PRESSURE/VELOCITY, DIN MB SPS 907463 SENSOR, AIR PRESSURE/VELOCITY, DIN MB T 09947707 MICRON Transformer, CPT, W/ FB, 00 MB T 09947760 Cover, Terminals, Micron 6-terminal MB T 09947740 Cover, Fuseholder, Micron Type Tr MB T 04050030 Washer, /4" Flat MB T 93444904 Washer, Split Lock MB T 349937303 Transformers 75va 0V-4Vac MB T3 349937303 Transformers 75va 0V-4Vac MB T6 0994774 MICRON Transformer, CPT, WO/ FB, 0 MB T6 09947760 Cover, Terminals, Micron 6-terminal MB T6 04050030 Washer, /4" Flat Note that all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options selected. RoofPak, Evaporative Condensing Units; RPE, RDE 076-50 C Rev. K 07/6 RPL 700094 / Page 8