Safety Electrical Equipment. Short Catalogue

Similar documents
Helyum. Feam Product Brochure LOCATION CERTIFICATES REFERENCES. Milan / ITALY ATEX, IECEX, EX GOST, INMETRO, NEC500-5

SOLUZIONI PER ATMOSFERA ESPLOSIVA

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

Basic Ex products / Zone 1, 21

Cable Glands DB Series: Drain, Breather Valves and Unions

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

DTS Light fittings for explosive atmospheres

LED lighting systems. Solutions for hazardous areas and safe area industry

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

The value of experience

XLFE-4/1. Borosilicate glass globe

Ex LED light fittings

Hazardous Area Products

ELECTRICAL EX EQUIPMENT

High bay LED lighting fixture

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

Industrial Hazardous Area Products

A2S s Company Profile

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

NERGYTOWER. energytower Leader in style, quality and safety. ground distribution turrets

your dust explosion protection experts

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Integrated Solutions Low Voltage Systems

Applications. Standard Materials

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

GUB. Ex d. Screw-on lid. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 8 sizes - IP66. Polyester coating. Cast mounting feet

Telephony & Communication

WHO WE ARE AND WHAT WE DO

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

LMV Series W Low Profile - Medium Base

Industrial & Hazardous Area Electrical Equipment

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

IECEx Certificate of Conformity

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

Explosion-proof Immersion Heater Type D-8660

300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug

Electrical Installations Design, Selection, Erection and Inspection

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

new new Industrial plugs and sockets

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

INTRINSICALLY SAFE LIGHTING RANGE

Transportation. Distribution

OPTIBAR DP 7060 Supplementary Instructions

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

MANUFACTURING PARTNER

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

PROFILE. industrial services rental trading

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

official distributor of Newson Gale Ltd.

distributing & controlling system solutions

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

ATM Lighting sp. z o.o

polar zone components and systems for extreme temperatures

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

SECTION EXTERIOR LIGHTING

ATM Lighting sp. z o.o

An Introduction to Barrier Ex Hazardous Area Solutions 2016/2017. Conformity Guaranteeing Safety

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

LTFX Electric Tank Immersion Heaters Installation Instructions

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Electrical Equipment & Systems

EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS

Ex Mark:Ex d eb ⅡB T6 Gb

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

ELSTA MOSDORFER- Energy Distribution with Competence

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

HAZARDOUS AREA SOLUTIONS

Description. Applications

Certificate of Compliance

Dräger Polytron 5700 IR Detection of flammable gases and vapours

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

Crouse-Hinds Enclosures. High performance, high reliability enclosures for global applications

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

Transcription:

Safety Electrical Equipment 2011 Short Catalogue

The value of dedicated specialisation. Founded in 1984, Nuova Asp established itself in the industrial plant security sector where work is carried out in potentially dangerous and areas with inflammable materials and explosive gases. In particular, the company designs and produces electrical security equipment for explosion-proof and waterproof electrical plant used in the chemical and petrochemical industries. The optimisation and constant updating of productive processes make it possible for the company to offer the best possible solutions for each client, from bulk production to limited and also personalised series. Nuova ASP today. Two companies now make up the Nuova Asp Group; a marketing company and the new productive unit, which was set up in 2006 with substantial resources. The result of this investment has been the competitive advantage that derives from a direct control of costs across all phases of production. Quality. The environment. Real security. Quality is the cornerstone of both the processes and the approach of Nuova Asp and operating in a logic centred on excellence has won the company a series of important certifications. In 1994, Nuova Asp was one of the first Italian companies to achieve CSQ certification, according to ISO 9002. The company subsequently received system quality certification UNI EN ISO 9001/2000. Moreover the production processes have Atex notification, for being realised and controlled thanks to advanced technologies. The norms make it possible to identify companies compliance in the production of equipment and protection systems designed for use in potentially explosive environments. In the area of environmental impact, Nuova Asp will soon obtain EMAS (2009) certification, thanks to its rigorous respect of environmental procedures. Moreover, research is being conducted into the development of alternatives to the sort of materials that can pose a threat to the environment, even if current norms continue to permit their use. A complete and secure range. The range of electro-mechanical equipment for potentially explosive environments designed and produced by Nuova Asp is both complete and subject to personalisation to meet with clients specific needs.

make them safe Productive range Lighting and receptacle socket outket panel boards Motor starters panel boards Control system earthing panel boards Marshalling, pulling and junction boxes in GRP, aluminium and stainless steel Instruments housings Ex ed control stations in GRP, aluminium and stainless steel enclosures Circuit breakers, on-load switch and selector switches Receptacle socket outlets in resin or aluminium with junction box Incandescent, fluorescent and discharge lamps lighting fixtures Emergency lighting fixtures Traffic lights Obstruction lights Warning lights Horns, bells and sirens Cable glands Sealing fittings Junction and pulling boxes Accessories for Ex zone as reducers, adaptors, elbows, flexibles etc. Materials used Aluminium alloy with less than 0.1% copper Stainless steel Fibreglass reinforced polyester Brass A variety of markets, a single interlocutor. Nuova Asp operates in a variety of market sectors and its interlocutors are equally varied, both domestically and in international markets. As an authentic partner to its customers, Nuova Asp offers products and support across the entire supply chain, from consulting services in the design stage - guaranteeing genuinely personalised solutions - to after-sales assistance. Nuova Asp s main interlocutors are: oil companies, companies engaged in the production and distribution of electricity, refineries, gas distribution companies, water purification companies, nuclear plants, engineering firms, municipal bodies, installation companies, the timber industry, the chemical industry, agribusiness companies, the pharmaceutical industry, mining companies, storage and warehousing companies, airports. The business of our clients are often in the front line of technological challenges. Nuova Asp is proud to support them, anywhere in the world. Great organisation, great partners. Choosing Nuova Asp means being able to depend on an organisation that can guarantee high quality intervention always and anywhere. Nuova Asp has a range of competent and qualified partners, able to develop not only the market but also to manage effective production, with the guarantee of the operational and productive excellence of Nuova Asp. To ensure this, the company conducts an authentic quality audit with ISO standards, in order to certify the phases that are contracted out to its partners. Thanks to its high level of specialisation, the Nuova Asp Group is a point of reference of absolute SECURITY for all of its customers.

Short Catalogue 2011 Safety Electrical Equipment EJB SERIES ALUMINIUM ENCLOSURES This enclosure is used as panel board or terminal box, with the installation of electrical equipment (switches, signals, circuit breakers, on-load switches transformers, ect). The cover, on request, will be equipped with glass to visualize instruments mounted inside. II 2 GD Ex d IIB + H2 code: EJB EJB SERIES AISI 316L ENCLOSURES This enclosure is used as terminal box or panel board, with the installation of electrical equipment (switches, signals, circuit breakers, on-load switches, transformers, ect). The cover may be equipped with trasparent glass to visualize instruments mounted inside. II 2 GD Ex d IIB + H2 Stainless steel AISI 316L body and cover. Hardware in stainless steel, AISI 316 standard. code: EJBX GUB SERIES ENCLOSURES This enclosure is used as panel board or terminal box, with the installation of electrical equipment (switches, signals, circuit breakers, on-load switches, transformers, ect). The cover, on request, will be equipped with glass to visualize instruments mounted inside. code: GUB GROUNDING SYSTEMS The earthing control system is made using our enclosures EJB or GUB, for tanker trucks during loading/unloading operations for flammable liquids inside hazardous locations. The system is complete with earthing clamp and connection cable. II 2 GD Ex d IIB + H2 code: EJB.SM - GUB.SM 04

GRP JUNCTION BOXES This enclosure is used as pulling box or terminal box, with the installation of terminals or bus-bars of different sizes. The size of boxes are modular so to joint together through specially designed flanges granting the IP protection. GRP (glass reinforced polyester) resin body and cover. Colours : black (Ex-e), blue (Ex-i) and light grey (Ex-n) code: AS II 2 GD Ex e II II 2 GD Ex ia IIC II 3GD Ex na II ZONE 2-22 AISI 316L STAINLESS STEEL JUNCTION BOXES This enclosure is used as pulling box or terminal box, with the installation of terminals or bus-bars of different sizes. The size of boxes are modular so to joint together through sealing gaskets granting the IP protection. This enclosure can be supplied also with removable flanges on each side. Stainless steel AISI 316L body and cover. Hardware in stainless steel AISI 316L standard code: ESX II 2 GD Ex e II II 2 GD Ex ia IIC II 3GD Ex na II ZONE 2-22 ALUMINIUM JUNCTION BOXES This enclosure is used as pulling box or terminal box, with the installation of terminals or bus-bars of different sizes. code: ESA II 2 GD Ex e II II 2 GD Ex ia IIC II 3GD Ex na II ZONE 2-22 INSTRUMENT HOUSINGS This enclosure is used as instrument housing such as digital or analogue ammeters and voltmeters. Can be also equipped with optical instruments such digital cameras and photoelectric lighting controls. Hardware in stainless steel Borosilicate glass window. code: EMH 05

Short Catalogue 2011 AISI 316L OR ALUMINIUM ENCLOSURE FOR CONTROL STATIONS This enclosure can be fitted with push buttons, pilot lights, emergency push buttorn with cover protection, mushroom with key and stayput, selector switches and analogic or digital instruments. Copper-free aluminium alloy epoxy coated or in stainlees steel AISI 316L body and cover. Hardware in stainless steel AISI 316 standard. Colours : grey (Ex-e and Ex-n), blue (Ex-i). Other colours on request. code: ESACS - ESXCS II 2 GD Ex ed IIC II 2 GD Ex ia IIC II 3GD Ex na II ZONE 2-22 GRP ENCLOSURE FOR CONTROL STATIONS This enclosure can be fitted with push buttons, pilot lights, emergency push buttorn with cover protection, mushroom with key and stayput, selector switches analogic or digital instruments. GRP (glass reinforced polyester) resin body and cover. Colours : black (Ex-e), blue (Ex-i)and light grey (Ex-n) code: ASCS II 2 GD Ex ed IIC II 2 GD Ex ia IIC II 3GD Ex na II ZONE 2-22 ALUMINIUM ENCLOSURE FOR CONTROL STATIONS This enclosure can be fitted with push buttons, pilot lights, emergency push buttorn with glass protection, mushroom with key and stayput and selector switches. code: EFDC ALUMINIUM ENCLOSURE FOR CIRCUIT BREAKER This enclosure can be fitted with thermomagnetic circuit breaker used for command and protection of three-phase motors. The circuit breaker has an adjustable thermomagnetic protection and an external control. II 2 GD Ex d IIB code: EFSC 218 06

ALUMINIUM ENCLOSURE FOR SWITCHES AND SELECTORS This enclosure can be fitted with rotary type switches, changeover switches and selectors with wide range of command cam equipment. code: EFSC GRP ENCLOSURE FOR RECEPTACLE SOCKET OUTLET The socket and plug serie APC is complete with interlocked disconnection switch for 16 and 32 Amps. Suitable for highly corrosive environments with a special self-cleaning feature. II 2 GD Ex ed IIC GRP (glass reinforced polyester) resin body and cover. Colours: black. code: APC ALUMINIUM RECEPTACLE SOCKET OUTLET The socket and plug serie SFQ is provided with on-load switch and plugging is possible, for safety reasons, only with open on-load switch. Power is switched on by means of a short twist of the plug. Available with 3 or 4 poles up to 16 Amp. Hardware in stainless steel. Ex-d IIC socket code: SFQP plug code: SFQS ALUMINIUM RECEPTACLE SOCKET OUTLET The socket and plug serie FSQCA is provided with on-load switch and plugging is possible, for safety reasons, only with open on-load switch. Power is switched on by means of a short twist of the plug. Available with 3 or 4 poles up to 32 Amp. socket code: SFQPa plug code: SFQS 07

Short Catalogue 2011 WELLGLASS LIGHTING FIXTURES This lighting fixture is normally fitted with incandescent and energy saving lamps. It s normally used for indoor and outdoor illumination areas which requires concentrated, diffuse or ambient light. Borosilicate glass globe. code: EVAC-IE WELLGLASS LIGHTING FIXTURES This lighting fixture is normally fitted with discharge lamps, such as metal halide, high pressure sodium vapour and mercury vapour. It s normally used for indoor and outdoor illumination areas which requires concentrated, diffuse or ambient light. Borosilicate glass globe. code: EVAC-D BULKHEAD LIGHTING FIXTURES This lighting fixture is normally fitted with incandescent and energy saving lamps. It s normally used for illumination of places which requires small and flat shape, such as tunnels and walking passages. Borosilicate glass globe. code: EVT TANK PORTHOLE LIGHTING FIXTURES This lighting fixture is normally fitted with incandescent and energy saving lamps. It s used, via a porthole, for illumination of the interior of tanks containing flammable products. Borosilicate glass window. code: EVO 08

GRP FLUORESCENT LIGHTING FIXTURES This lighting fixtures can be fitted with double bi-pin fluorescent tube. Also available as emergency unit complete with integrated battery pack. Specially indicated for highly corrosive environments and marine applications. II 2 GD Ex ed IIC Body in GRP (glass reinforced polyester) resin Trasparent diffuser in antistatic polycarbonate. Colours: black standard, grey colour on request. code: AVF FLUORESCENT LIGHTING FIXTURES This lighting fixtures can be fitted with double bi-pin fluorescent tube. Also available as emergency unit complete with integrated battery pack. Specially indicated for highly corrosive environments and marine applications. Borosilicate glass tube. code: EVF FLUORESCENT LIGHTING FIXTURES This lighting fixtures can be fitted with double bi-pin fluorescent tube. Also available as emergency unit complete with integrated battery pack. Specially indicated for highly corrosive environments and marine applications. II 3GD Ex na II ZONE 2-22 Body in polycarbonate. Trasparent diffuser in polycarbonate. Hardware in stainless steel, AISI 304 standard. Colour body: grey. code: AVNA FLOODLIGHTS AND WELLGLASS LIGHTING FIXTURES These floodlights and lighting fixtures are normally fitted with discharge lamps, such as metal halide, high pressure sodium vapour and mercury vapour. They are normally used for indoor and outdoor illumination of areas which requires concentrated, diffuse or ambient light. II 3GD Ex nr II ZONE 2-22 Copper-free aluminium alloy body. Temperated glass cover with closing clips in stainless steel. Epoxy coating grey. Other colours on request code: SFNR 09

Short Catalogue 2011 FLOODLIGHTS This floodlight can be equipped with incandescent lamp up to 500W and metal halide and high pressure sodium up to 400W. It s normally used for in-door and out-door illumination of areas which requires wide beam light. II 2 GD Ex d IIB Borosilicate glass window. code: SFD - SFDE FLOODLIGHTS This floodlight can be equipped with incandescent lamp up to 500W and metal halide and high pressure sodium up to 400W. It s normally used in marine and offshore platforms for illumination of areas that requires concentrated light. Borosilicate glass window. code: RCDE FLUORESCENT LIGHTING FIXTURES This compact model has been designed as emergency light source Equipped with different sign boards, it can be conveniently used for emergency or danger warnings. II 2 GD Ex d IIB Borosilicate glass window. code: EJB08 TRAFFIC LIGHTS The traffic light is made with EVT housing and is available in different combination of units coloured with additional prismatic lens. it s suitable to be used in any hazardous area, without any limitation of gas group or corrosive atmosphere. Borosilicate glass window and policarbonate lens. code: EVT 10

OBSTRUCTION LIGHTING FIXTURES This lighting fixture is normally fitted with incandescent and energy saving lamps. It s normally used for installation on towers or high buildings as obstruction signal. Borosilicate glass globe. Adjuntive FRESNEL globe in polycarbonate. code: EVAC-OL WARNING LIGHTING FIXTURES This lighting fixture is normally fitted with rotating or flashing lamps, with different colours and functioning. It s normally used for installation together acoustic equipment to signal breakdowns, alarms, warnings, ect. Borosilicate glass globe. code: EVAC-WL HORNS AND BELLS These acoustic signallers are equipped with sounds with different intensity and frequency so to cover the main warning regulations inside hazardous areas. They are normally used for installation together visual equipment to signal breakdowns, alarms, warnings, ect. code: ETH SIRENS These acoustic signallers are equipped with sounds with different intensity and frequency so to cover the main warning regulations inside hazardous areas. They are normally used for installation together visual equipment to signal breakdowns, alarms, warnings, ect. code: S2 11

Short Catalogue 2011 CABLE GLANDS These cable glands are used for connecting Ex equipment using unarmoured cables. When requested a mechanical protection to the cable with a rigid or flexible conduit, a special threaded entry is provided into the external termination of the cable gland (model PNAF - PNEF). Material: nickel plated brass - brass - stainless steel. Standard threads: NPT - ISO 228 - ISO 7.1 METRIC. Other type of threads on request. II 2 GD Ex e II code: PNS - PNA - PNE - PNAF - PNEF CABLE GLANDS These cable glands are used for connecting Ex equipment using armoured cables. Available with single and double sealing system. Material: nickel plated brass - brass - stainless steel. Standard threads: NPT - ISO 228 - ISO 7.1 METRIC. Other type of threads on request. II 2 GD Ex e II code: PS - PA - PE - PAS - PAP - PAE CABLE GLANDS These cable glands are used for connecting Ex equipment housed in GRP or stainless steel enclosures using unarmoured cables. Available in black (Ex-e) and blue (Ex-i) colour. Material: polyamid. Standard threads: ISO (pitch 1,5) - PG 40430. II 2 GD Ex e II II 2 GD Ex i II code: PCE SEALING FITTINGS Sealing fittings prevent passage of gas, vapours or flames through the conduit system, from one side to the other of the electrical installation. EZS is suitable for both horizontal/vertical installation while EYS is only for vertical one. The sealing fitting are supplied together the bi-component resin. Epoxy coating on request. code: EYS - EZS 12

JUNCTION AND PULLING BOXES These enclosures are used as terminal boxes or pulling boxes. They are made in round shape with a large combination of entries so to cover all the installation requirements of a conduit system. Epoxy coating on request. code: SB - SC - SL - ST - SX - SW - SD - SM - SJ ELBOWS These enclosures are used as pulling boxes, in a combination of different radius, so to cover all the installations requirements of a complete conduit system. II 2 GD Ex d IIB - IIC Epoxy coating on request. code: LBH - LBHS - LBY - ELF - ELM - ELMF FLEXIBLE AND RIGID CONDUITS The flexible conduits are used for connecting vibrating equipment, such as electrical motors, or as alternative to rigid conduit installation if this is too complicated. For rigid conduit installation system is available a wide range of accessories such as saddles, clamps, u-bolts, bushings, couplings and locknuts. II 2 GD Ex d IIB - IIC Material: galvanized steel - stainless steel. Standard threads: NPT - ISO 7.1 METRIC. Other type of threads on request. code: TFII - TR - GF - BU - CST - MP - MT - EM - MC - DL - DB CONDUIT FITTINGS These fittings are used in the conduit installations for connecting the different types of equipment. Three pieces unions, reducers, adaptors and nipples in a complete range of combinations of male/ female connection provides the solution to any problem given by this complicated system. II 2 GD Ex d IIB - IIC Material: galvanized steel or stainless steel. Standard threads: NPT - ISO 7.1 METRIC. Other type of threads on request. code: BMF - BMM - BFF - RE - REB - REM - REN - NP - PLG 13

Tailor made switchracks and panel boards Our Commercial and Technical staff can assist you in execution of switchracks and panel boards specially designed following customer s specifications. This service is provided directly by our factory in Italy and by our authorized assembly-points located in the most significant regions of the world. These special executions are made in accordance to the main types of protections such Ex d, Ex de suitable for heavy-duty enviroments. Quality and Protection The costant improvement of the quality of our services and our products represents our top priority. Our quality management system is certify as complying with ISO 9001:2008. This internationally recognized standard assures the quality of every stage, from design to shipment, in our Company since 1995. The reliability and high technical standard of our products are attested by the approval of international notified bodies in conformity with ATEX and IEC-EX standard. Our Company has been notified with certificate CESI 01 ATEX 073Q attesting the compliance to Atex Directive, and more recently, the first one in our country, with certificate IT/CES QAR06.0001/04 attesting the compliance to IEC- EX, the new international standard for EX equipment. 14

Service and Support The scope of the present broshure is to give an overview of our range of products and services. Our Company is oriented in improving and updating continuosly the commercial and technical informations and the level of services to our customers. The following instruments are actually at your disposal and some others will be available soon. GENERAL CATALOGUE A technical description of our full range of products. Safety Electrical Equipment Apparecchiature elettriche di sicurezza 2011 General Catalogue COMPANY PROFILE A general overwiew on our working capacity and customer service. Company Profile Safety Electrical Equipment OFFICIAL WEBSITE The interactive door to our company and our online electronic catalogue. PHOTOMETRIC CURVES COLLECTION The full collection of photometric curves of our lighting fixtures are at your disposal for lighting calculation. CERTIFIED FUNCTIONAL SYSTEM CONFIGBLOCK Guideline for configuration of complexes systems of the full range of our enclosures AS; ESA; ESX; GUB and EJB. 15

Main Office Via De Gasperi, 26 20090 Pantigliate - MI - Italy Tel. +39 02 90686013 Fax +39 02 90686179 Production unit Nuova ASP s.r.l. Via Giosuè Carducci, 16 34070 Moraro - GO - Italy Tel. +39 0481 881054 Fax +39 0481 809155 Middle East Nuova ASP Middle East LLC PO Box 49078 Dubai - United Arab Emirates Tel. +971 4 2587796 Fax +971 4 2587762 Far East Nuova ASP - Shanghai Representative Office No. 7 Hui Xian Yuan, Dalian High-Tech Industrial Zone #08-02, Dalian China 116025 Tel. +86-411-39668787*208 Fax +86-411-39668789 Malaysia Nuova ASP (M) Sdn. Bhd. Lot 6, Jalan RP, Rawang Industrial Estate, Rawang Perdana, 48000 Rawang, Selangor, Malaysia Tel. +603 6092 1730, 6093 1730 Fax +603 60935730 www.nuovaasp.net info@nuovaasp.net Agent