Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Similar documents
Wall Mounted Split Systems

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Models: A5HDC20AR A5HDC25AR. Horizontal Ducted Condensing Unit

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Horizontal Water Source Heat Pumps And Cooling Only Unit

Ducted Blower Split Systems

Highly Efficient,Powerful Heating and Cooling.

INVERTER Y SINGLE SPLIT SERIES II

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Concealed Ducted Split Series R-407C MBH

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

AIR-CONDITIONER SERVICE MANUAL

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Air conditioners Cooling only

2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller.

R407C TECHNICAL MANUAL. Packaged Air Conditioner Rooftop A series. UATP-A and UATYP-A Series. Cooling only & Heatpump [50Hz]

PAJ3. Product Specifications

ROOFTOP PACKAGE (GC201105) TECHNICAL SALES GUIDE-50&60Hz CAPACITY RANGE:3~30TON SUPER HIGH AMBIENT OPERATION TO 55

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

[U] Serie MHB / MHA Manual de Ingeniería

Models: A5LCY 30 ER A5LCY 40 ER A5LCY 50 ER A5LCY 60 ER A5LCY - II Inverter Y Single Split Series II

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

TM: MCCKCM - W B. Fan Coil Units. Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

R4H4. Product Specifications

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

R4H4. Product Specifications

MAC-120HE-03 Air-Cooled Chiller

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

LOW STATIC HYDRONIC DUCTED UNIT

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

DESIGN & TECHNICAL MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161

Floor-Standing Type(E Series)

EHH SERIES DRAW THROUGH FAN COILS CFM

N4H4. Product Specifications

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Air Conditioner SVC MANUAL(Exploded View)

GENERAL ELECTRIC AIR HANDLING UNITS DIRECT EXPANSION. ABQ Series ABQ03 thru ABQ TR thru 30 TR 9 kw thru 105 kw

Split Water Source Heat Pump And Cooling Only Unit

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Commercial High-Efficiency Condensing Units

WCH5**4. Product Specifications

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Technical Data Ducted Three Phase Split System Air Conditioner

WJH4 Product Specifications

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

RC-0219-A. Single-Split Non Inverter Series

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

VertiCool Aurora Engineering Guide

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A

E U R O V E N T CERTIFIED PERFORMANCE

DESIGN & TECHNICAL MANUAL

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

PACKAGE AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Wall Mounted Split Systems

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Table of Contents. Page 2

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

MAC N-407 Air-Cooled Chiller

next DX.U.S* 052.Z2.H6.DC

PAR5. Product Specifications

GENERAL ELECTRIC VERTICAL PACKAGED UNITS

C&H NORDIC Commercial 4 SERVICE MANUAL

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

DESIGN & TECHNICAL MANUAL

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

DESIGN & TECHNICAL MANUAL

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Transcription:

Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems

CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE... 22 6. SOUND DATA... 23 7. PERFORMANCE TABLE... 25 8. OUTLINES AND DIMENSIONS... 35 9. REFRIGERANT CIRCUIT... 37 10. WIRING DIAGRAMS... 38 11. INSTALLATION... 40 12. SERVICING AND MAINTENANCE... 43 13. TROUBLESHOOTING... 45 14. EXPLODED VIEW AND PARTS LIST... 51

1. NOMENCLATURE INDOOR Product Specification Variation A : First Issue Type of Connection B : For Brazed Electrical Characteristic A : 50Hz / 1Ph / 220-240V A CC 75 D R - A B A A Model Type R : Heatpump Omitted if Cooling Only Series D : D Series Capacity 75 : 75,000 Btu/h Model Name CC : Ceiling Concealed Refrigerant Blank : R22 4 : R407C Brand A : Acson 2

OUTDOOR Product Specification Variation A : First issue Type of Connection B : For Brazed Electrical Characteristic F : 50Hz / 3Ph / 220-240V P : 60Hz / 3Ph / 208-230V Q : 60Hz / 3Ph / 460V A MC 75 E R - F B A A Model Type R : Heatpump Omitted if Cooling Only Series E : E Series D : D Series Capacity 75 : 75,000 Btu/h Model Name MC : Single Split Condensing Unit Refrigerant Blank : R22 4 : R407C Brand A : Acson 3

2. FEATURES Invisible Operation The unit is installed concealed above the ceiling. ACC-D is designed to intelligently create a comfortable and healthy indoor air climate, while remaining invisible. This allows user to enjoy conditioned air without sacrificing room space or interior design creativity. Flexibility in System Design The unit offers fan motor that can operate up to 4 speeds, thus provide choices of external static pressure for designing ducting system. Easy Serviceability With the concept of easy serviceability in mind, ACC-D series is designed for easy access to internal components. The internal components, such as fan motor or blower, can be easily accessed for servicing through both sides or bottom of the unit. High Level of Protection The unit is incorporated with a unique safety feature, i.e. a float switch, to provide an additional protection from possible problems of condensate water over flow inside the unit. Once the condensate water reaches critical level, the level switch will be activated and signal will be sent to the microprocessor controller to stop the compressor as well as sending an error message to the wired controller, alerting the user, for further action. Wired Remote Controller The standard unit comes with the Netware III controller, which offers wide range of control features that, includes 7 days and 24 hours timer setting and more. The ACC-D series is able to communicate with the versatile NIM network control module and offers the opportunity of one centralized control for a system of multiple indoor units in a building. Auto Random Restart Auto random restart function allows the unit to automatic restart as the last setting condition when the power supply is resumed after power failure. However, the compressor will restart randomly if more than one unit is installed and sharing the same phase of power. Self Diagnosis The microprocessor provides the possibility to detect and diagnose any fault or malfunction that occurs in the system. The error will be reflected by the wired remote controller with a series of error code. 4

3. PRODUCT LINE UP INDOOR UNIT ACC-D SERIES PRODUCT LINE UP Classification ACC NONMENCLATURE Handset NETWARE III Control Module L2 Filtration Air Filter Marking CE Mark Refrigerant Control Cap. Tube TXV Level Switch Built-in Filter Rail Auto Random Restart Heat Pump Model 75DR 100DR ABAA X X X X X X X X ABAA X X X X X X X X 5

OUTDOOR UNIT AMC-D Series Product Line Up Classification Cooling Only Model AMC Nomenclature With Contactor Controller Without Contactor With 24Vac Control Circuit With Auto HP/LP With Manual HP/LP CE Mark Marking ETL Without Marking FBAF X X X X X X FBAG X X X X X X FBAH X X X X X X FCAA X X X X X X FCAB X X X X X X X 75D PBAB X X X X X 1/2 1 PBAC X X X X X X X PCAA X X X X X X QBAB X X X X X QBAC X X X X X X X QCAB X X X X X X X X FBAF X X X X X X FBAG X X X X X X FBAH X X X X X X FCAA X X X X X X FCAB X X X X X X X 100D PBAB X X X X X 5/8 1-1/8 PBAC X X X X X X X PCAA X X X X X X QBAB X X X X X QBAC X X X X X X X QCAB X X X X X X X X Compressor Scroll-Copeland Refrigerant Control TXV Without Expansion Device Rivet "Made In Malaysia" With Accumulator Others With Type Brazed Ball Valve Phase Protector Gold Fin (NA549) Liquid Pipe Size (in) Gas Pipe Size (in) A4MC-D Series Product Line Up Classification Cooling Only Model A4MC Nomenclature With Contactor Controller Auto HP/LP Marking CE Mark Compressor Scroll-Copeland Refrigerant Control TXV FBAA X X X X X X 75D FBAA X X X X X X X FCAA X X X X X X X 1/2 1 FCAB X X X X X X X X X FBAA X X X X X X 100D FBAA X X X X X X X FCAA X X X X X X X 5/8 1-1/8 FCAB X X X X X X X X X Without Expansion Device For Sequential Controller Others With Accumulator With Type Brazed Ball Valve Gold Fin (NA549) Liquid Pipe Size (in) Gas pipe size (in) 6

Outdoor Unit AMC-ER Series Product Line Up Classification HEATPUMP MODLES MSS Nomenclature With Contactor Controller With Auto HP/LP Marking CE Mark Compressor Scroll-Copeland Refrigerant Control TXV Without Expansion Device FBAA X X X X X X 75ER FBAB X X X X X X X FBAC X X X X X X X 1/2 1 FCAA X X X X X X X FBAA X X X X X X 100ER FBAB X X X X X X X FBAC X X X X X X X 5/8 1-1/8 FCAA X X X X X X X FBAA X X X X X X 125ER FBAB X X X X X X X FBAC X X X X X X X X 5/8 1-3/8 FCAA X X X X X X X FBAA X X X X X X 150ER FBAB X X X X X X X X 5/8 1-3/8 FCAA X X X X X X X For Sequential Controller Gold Fin (NA549) Others Rivet "Made In Malaysia" With Brazed Type Ball Valve Check valve Phase Sequencer Liquid Pipe Size (in) Gas Pipe Size (in) A4MC-ER Series Product Line Up Classification 4MSS Nomenclature With Contactor Controller With Auto HP/LP Marking CE Mark Compressor Scroll-Copeland Refrigerant Control TXV Without Expansion Device For Sequential Controller Others Gold Fin (NA549) With Accumulator With Brazed Type Ball Valve Liquid Pipe Size (in) Gas Pipe Size (in) Heatpump Models 75ER 100ER 125ER 150ER FBAA X X X X X X FCAA X X X X X X X FBAA X X X X X X FCAA X X X X X X X FBAA X X X X X X FCAA X X X X X X X FBAA X X X X X X FCAA X X X X X X X 1/2 5/8 5/8 5/8 1 1-1/8 1-3/8 1-3/8 7

4. SPECIFICATIONS General Data - Cooling Only (R22) MODEL NOMINAL CAPACITY INDOOR UNIT Btu/h ACC 75D 75,000 ACC 100D 95,000 OUTDOOR UNIT W AMC 75D 21,960 AMC 100D 27,820 NOMINAL TOTAL INPUT POWER W 8,471 10,822 NOMINAL RUNNING CURRENT A 16.3 19.4 POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 REFRIGERANT / CONTROL R22 / INDOOR TXV SUPER HIGH CFM / L/s 2420 / 1142 3150 / 1487 AIR FLOW HIGH CFM / L/s 2450 / 1156 3130 / 1477 MEDIUM CFM / L/s 2000 / 944 2840 / 1340 LOW CFM / L/s 1680 / 793 2240 / 1057 EXTERNAL STATIC PRESSURE (SH/H/M/L) mmaq(pa) 20 / 14 / 10 / 7 (196 / 137 / 98 / 69) OUTDOOR UNIT INDOOR UNIT SOUND PRESSURE LEVEL (SH/H/M/L) dba 52 / 52 / 48 / 43 55 / 54 / 52 / 48 HEIGHT 430 / 16.9 430 / 16.9 UNIT DIMENSION WIDTH 1426 / 56.1 1655 / 65.2 DEPTH 826 / 32.5 826 / 32.5 HEIGHT 612 / 24.1 612 / 24.1 PACKING DIMENSION WIDTH 1535 / 60.4 1765 / 69.5 DEPTH 974 / 38.3 974 / 38.3 UNIT WEIGHT kg/lb 92 / 203 119 / 262 CONDENSATE DRAIN SIZE 25.4 / 1.0 25.4 / 1.0 AIR FLOW SOUND PRESSURE LEVEL CFM / L/s dba 7000 / 3304 64 UNIT DIMENSION PACKING DIMENSION HEIGHT WIDTH DEPTH HEIGHT WIDTH DEPTH 1041 / 40.98 981 / 38.62 981 / 38.62 1224 / 48.2 1175 / 46.3 1150 / 45.3 UNIT WEIGHT kg/lb 170 / 374 184 / 405 BRAZING PIPE CONNECTION LIQUID 12.70 / 1/2 15.88 / 5/8 SIZE GAS 25.40 / 1 28.57 / 1-1/8 REFRIGERANT CHARGE kg/lb 6.7 / 14.77 10.5 / 23.15 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI 210/240-94. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 26.7 C DB / 19.4 C WB INDOOR AND 35.0 C DB / 23.9 C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 8

Electrical Data - Cooling Only (R22) MODEL INDOOR UNIT ACC 75D ACC 100D OUTDOOR UNIT AMC 75D AMC 100D INDUCTION INSULATION GRADE CLASS B POWER SOURCE V/Ph/Hz 220-240 / 1 / 50 INDOOR MOTOR RATED INPUT POWER W 1061 1254 RATED RUNNING CURRENT A 4.51 5.79 MOTOR OUTPUT W 750 1000 POLES 4 4 INDUCTION INSULATION GRADE CLASS F OUTDOOR MOTOR POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 RATED INPUT POWER W 600 RATED RUNNING CURRENT A 1.2 MOTOR OUTPUT W 350 SCROLL INSULATION GRADE N/A N/A POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 COMPRESSOR CAPACITOR µf NIL NIL RATED INPUT POWER W 6810 8968 RATED RUNNING CURRENT A 13.6 16.3 LOCKED ROTOR AMP. A 95 125 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI 210/230-94. 9

Components Data (R22) MODEL INDOOR FAN INDOOR FAN MOTOR OUTDOOR FAN OUTDOOR FAN MOTOR COMPRESSOR INDOOR COIL OUTDOOR COIL FILTRATION CASING INDOOR UNIT OUTDOOR UNIT Q'TY DRIVE DIAMETER LENGTH Q'TY INDEX OF PROTECTION (IP) Q'TY DRIVE DIAMETER Q'TY INDEX OF PROTECTION (IP) OIL ACC 75D AMC 75D 2 ZINC COATED STEEL DIRECT ACC 100D ALC 100D ZINC COATED STEEL DIRECT 228.6 / 9.0 228.6 / 9.0 177.8 / 7.0 228.6 / 9.0 1 N/A N/A SONTEX 200 LT N/A N/A SONTEX 200 LT OIL AMOUNT cm 3 2513 3253 TUBE FIN TUBE FIN SIZE DIAMETER THICKNESS ALUMINIUM ALUMINIUM THICKNESS 0.127 / 0.005 0.127 / 0.005 FACE AREA m 2 /ft 2 0.45 / 4.89 0.55 / 5.89 ROW FIN PER INCH DIAMETER THICKNESS 4 12 14 ALUMINIUM ALUMINIUM THICKNESS 0.127 / 0.005 0.127 / 0.005 FACE AREA m 2 /ft 2 2.29 / 24.72 2.29 / 24.72 1 20 16 WIDTH 665 / 26.1 780 / 30.7 HEIGHT 345 / 13.9 345 / 13.9 QUANTITY pc 2 INDOOR UNIT ROW OUTDOOR UNIT FIN PER INCH FINSIHING COLOUR FINISHING COLOUR CENTRIFUGAL INDUCTION PROPELLER 1 ALUMINIUM DIRECT 812.8 / 32.0 INDUCTION 1 SCROLL SEAMLESS COPPER 9.52 / 3/8 0.35 / 0.013 SEAMLESS COPPER 9.52 / 3/8 0.35 / 0.013 WASHABLE SARANET FILTER GALVANIZED MILD STEEL - - ELECTRO GALVANIZED STEEL EPOXY POLYESTER POWDER WHITE 2 1 4 2 2 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 10

General Data - Heat pump (R22) MODEL NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY INDOOR UNIT Btu/h Btu/h ACC 75DR 75000 84000 ACC 100DR 100000 110000 OUTDOOR UNIT W W AMC 75ER 21960 24600 AMC 100ER 29280 32210 NOMINAL TOTAL INPUT POWER (COOLING) W 7356 10200 NOMINAL TOTAL INPUT POWER (HEATING) W 7206 9800 NOMINAL RUNNING CURRENT (COOLING) A 13.6 17.9 NOMINAL RUNNING CURRENT (HEATING) A 13.3 17.2 POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 REFRIGERANT / CONTROL R22 / INDOOR & OUTDOOR TXV SUPER HIGH CFM / L/s 2420 / 1142 3150 / 1487 AIR FLOW HIGH CFM / L/s 2450 / 1156 3130 / 1477 MEDIUM CFM / L/s 2000 / 944 2840 / 1340 LOW CFM / L/s 1680 / 793 2240 / 1057 EXTERNAL STATIC PRESSURE (SH/H/M/L) mmaq(pa) 20 / 14 / 10 / 7 (196 / 137 / 98 / 69) INDOOR UNIT OUTDOOR UNIT SOUND PRESSURE LEVEL (SH/H/M/L) dba 52 / 52 / 48 / 43 55 / 54 / 52 / 48 HEIGHT 430 / 16.9 430 / 16.9 UNIT DIMENSION WIDTH 1426 / 56.1 1655 / 65.2 DEPTH 826 / 32.5 826 / 32.5 HEIGHT 612 / 24.1 612 / 24.1 PACKING DIMENSION WIDTH 1535 / 60.4 1765 / 69.5 DEPTH 974 / 38.3 974 / 38.3 UNIT WEIGHT kg/lb 92 / 203 119 / 262 CONDENSATE DRAIN SIZE 25.4 / 1.0 25.4 / 1.0 AIR FLOW SOUND PRESSURE LEVEL CFM / L/s dba 7000 / 3304 64 UNIT DIMENSION PACKING DIMENSION HEIGHT WIDTH DEPTH HEIGHT WIDTH DEPTH 1041 / 40.98 981 / 38.62 981 / 38.62 1224 / 48.2 1175 / 46.3 1150 / 45.3 UNIT WEIGHT kg/lb 170 / 374 184 / 405 BRAZING PIPE CONNECTION LIQUID 12.70 / 1/2 15.88 / 5/8 SIZE GAS 28.58 / 1-1/8 28.58 / 1-1/8 REFRIGERANT CHARGE kg/lb 6.80 / 14.99 7.50 / 16.54 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI 210/240-94. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7 C DB / 19.4 C WB INDOOR AND 35.0 C DB / 23.9 C WB OUTDOOR b) HEATING - 21.1 C DB INDOOR AND 8.3 C DB / 6.1 C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 11

Electrical Data - Heat pump (R22) MODEL INDOOR UNIT ACC 75DR ACC 100DR OUTDOOR UNIT AMC 75ER AMC 100ER INDUCTION INSULATION GRADE CLASS B POWER SOURCE V/Ph/Hz 220-240 / 1 / 50 INDOOR MOTOR RATED INPUT POWER W 1061 1254 RATED RUNNING CURRENT A 4.51 5.79 MOTOR OUTPUT W 750 1000 POLES 4 4 INDUCTION INSULATION GRADE CLASS F OUTDOOR MOTOR POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 RATED INPUT POWER W 600 RATED RUNNING CURRENT A 1.2 MOTOR OUTPUT W 350 SCROLL INSULATION GRADE N/A N/A POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 CAPACITOR µf NIL NIL COMPRESSOR RATED INPUT POWER (COOLING) W 5695 8346 RATED INPUT POWER (HEATING) W 5545 7966 RATED RUNNING CURRENT (COOLING) A 10.9 14.8 RATED RUNNING CURRENT (HEATING) A 10.6 14.1 LOCKED ROTOR AMP. A 95 125 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI210/240-94. 12

Components Data (R22) MODEL INDOOR FAN INDOOR FAN MOTOR OUTDOOR FAN OUTDOOR FAN MOTOR COMPRESSOR INDOOR COIL OUTDOOR COIL FILTRATION CASING INDOOR UNIT OUTDOOR UNIT Q'TY DRIVE DIAMETER LENGTH Q'TY INDEX OF PROTECTION (IP) Q'TY DRIVE DIAMETER Q'TY INDEX OF PROTECTION (IP) OIL ACC 75DR AMC 75ER 2 ZINC COATED STEEL DIRECT ACC 100DR AMC 100ER ZINC COATED STEEL DIRECT 228.6 / 9.0 228.6 / 9.0 177.8 / 7.0 228.6 / 9.0 1 N/A N/A Sontex 200 LT N/A N/A Sontex 200 LT OIL AMOUNT cm 3 2513 3253 TUBE FIN TUBE FIN SIZE DIAMETER THICKNESS ALUMINIUM ALUMINIUM THICKNESS 0.127 / 0.005 0.127 / 0.005 FACE AREA m 2 /ft 2 0.45 / 4.89 0.55 / 5.89 DIAMETER THICKNESS 4 12 14 ALUMINIUM ALUMINIUM THICKNESS 0.127 / 0.005 0.127 / 0.005 FACE AREA m 2 /ft 2 2.29 / 24.72 2.29 / 24.72 1 20 16 WIDTH 665 / 26.1 780 / 30.7 HEIGHT 345 / 13.9 345 / 13.9 QUANTITY pc 2 INDOOR UNIT ROW OUTDOOR UNIT FIN PER INCH ROW FIN PER INCH FINSIHING COLOUR FINISHING COLOUR CENTRIFUGAL INDUCTION PROPELLER 1 ALUMINIUM DIRECT 812.8 / 32.0 INDUCTION 1 SCROLL SEAMLESS COPPER 9.52 / 3/8 0.35 / 0.013 SEAMLESS INNER GROOVED COPPER 9.52 / 3/8 0.35 / 0.013 WASHABLE SARANET FILTER GALVANIZED MILD STEEL N/A N/A ELECTRO GALVANIZED STEEL EPOXY POLYESTER POWDER WHITE 2 1 4 2 2 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 13

Safety Devices MODEL SAFETY DEVICE INDOOR UNIT ACC 75D ACC 100D OUTDOOR UNIT AMC 75D AMC 100D HIGH PRESSURE SWITCH LOW PRESSURE SWITCH AUTO RESET AUTO RESET AUTO RESET AUTO RESET SETTING SETTING 426 psi OFF 18 psi OFF 426 psi OFF 18 psi OFF PHASE SEQUENCER AVAILABLE AVAILABLE DISCHARGE THERMOSTAT SETTING 130 o C 130 o C 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL SAFETY DEVICE INDOOR UNIT ACC 75DR ACC 100DR OUTDOOR UNIT AMC 75ER AMC 100ER HIGH PRESSURE SWITCH LOW PRESSURE SWITCH AUTO RESET AUTO RESET AUTO RESET AUTO RESET SETTING SETTING 426 psi OFF 7 psi OFF 426 psi OFF 7 psi OFF PHASE SEQUENCER AVAILABLE AVAILABLE DISCHARGE THERMOSTAT SETTING 130 o C 130 o C 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 14

General Data - Cooling Only (R407C) MODEL NOMINAL CAPACITY INDOOR UNIT Btu/h ACC 75D 75000 ACC 100D 100000 OUTDOOR UNIT W A4MC 75D 21980 A4MC 100D 29310 NOMINAL TOTAL INPUT POWER W 8892 10833 NOMINAL RUNNING CURRENT A 16.0 19.0 POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 REFRIGERANT / CONTROL R407C / INDOOR TXV SUPER HIGH CFM / L/s 2520 / 1189 3070 / 1449 AIR FLOW HIGH CFM / L/s 2320 / 1095 2620 / 1237 MEDIUM CFM / L/s 2095 / 989 2350 / 1109 LOW CFM / L/s 1660 / 783 2150 / 1015 EXTERNAL STATIC PRESSURE (SH/H/M/L) mmaq(pa) 20 / 14 / 10 / 7 (196 / 137 / 98 / 69) OUTDOOR UNIT INDOOR UNIT SOUND PRESSURE LEVEL (H/M/L) dba 52 / 52 / 48 / 43 55 / 54 / 52 / 48 HEIGHT 430 / 16.9 430 / 16.9 UNIT DIMENSION WIDTH 1426 / 56.1 1655 / 65.2 DEPTH 826 / 32.5 826 / 32.5 HEIGHT 612 / 24.1 612 / 24.1 PACKING DIMENSION WIDTH 1535 / 60.4 1765 / 69.5 DEPTH 974 / 38.3 974 / 38.3 UNIT WEIGHT kg/lb 92 / 203 119 / 262 CONDENSATE DRAIN SIZE 25.4 / 1.0 25.4 / 1.0 AIR FLOW SOUND PRESSURE LEVEL CFM / L/s dba 7000 / 3304 64 UNIT DIMENSION PACKING DIMENSION HEIGHT WIDTH DEPTH HEIGHT WIDTH DEPTH 1041 / 40.98 981 / 38.62 981 / 38.62 1224 / 48.2 1175 / 46.3 1150 / 45.3 UNIT WEIGHT kg/lb 170 / 374 184 / 405 BRAZING BRAZING PIPE CONNECTION LIQUID 12.70 / 1/2 15.88 / 5/8 SIZE GAS 25.40 / 1 28.57 / 1-1/8 REFRIGERANT CHARGE kg/lb 7.00 / 15.43 7.80 / 17.20 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI 210/240-94. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 26.7 C DB / 19.4 C WB INDOOR AND 35.0 C DB / 23.9 C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 15

Electrical Data - Cooling Only (R407C) MODEL INDOOR UNIT ACC 75D ACC 100D OUTDOOR UNIT A4MC 75D A4MC 100D INDUCTION INSULATION GRADE CLASS B POWER SOURCE V/Ph/Hz 220-240 / 1 / 50 INDOOR MOTOR RATED INPUT POWER W 1061 1254 RATED RUNNING CURRENT A 4.51 5.79 MOTOR OUTPUT W 750 1000 POLES 4 4 INDUCTION INSULATION GRADE CLASS F OUTDOOR MOTOR POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 RATED INPUT POWER W 600 RATED RUNNING CURRENT A 1.2 MOTOR OUTPUT W 350 SCROLL INSULATION GRADE N/A N/A POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 COMPRESSOR CAPACITOR µf NIL NIL RATED INPUT POWER W 7231 8979 RATED RUNNING CURRENT A 13.34 15.82 LOCKED ROTOR AMP. A 95 125 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI210/240-94. 16

Components Data (R407C) MODEL INDOOR FAN INDOOR FAN MOTOR OUTDOOR FAN OUTDOOR FAN MOTOR COMPRESSOR INDOOR COIL OUTDOOR COIL FILTRATION CASING INDOOR UNIT OUTDOOR UNIT Q'TY DRIVE DIAMETER LENGTH Q'TY INDEX OF PROTECTION (IP) Q'TY DRIVE DIAMETER Q'TY INDEX OF PROTECTION (IP) OIL ACC 75D A4MC 75D 1 ZINC COATED STEEL DIRECT ACC 100D A4MC 100D ZINC COATED STEEL DIRECT 228.6 / 9.0 228.6 / 9.0 177.8 / 7.0 228.6 / 9.0 1 N/A N/A SONTEX 200 LT N/A N/A SONTEX 200 LT OIL AMOUNT cm 3 2513 3253 TUBE FIN TUBE FIN SIZE S. I. G. C. SEAMLESS COPPER DIAMETER 9.52 / 3/8 9.52 / 3/8 THICKNESS 0.35 / 0.013 0.35 / 0.013 ALUMINIUM ALUMINIUM THICKNESS 0.127 / 0.005 0.127 / 0.005 FACE AREA m 2 /ft 2 0.45 / 4.89 0.55 / 5.89 ROW FIN PER INCH 4 12 14 S. I. G. C. SEAMLESS COPPER DIAMETER 9.52 / 3/8 9.52 / 3/8 THICKNESS 0.35 / 0.013 0.35 / 0.013 ALUMINIUM ALUMINIUM THICKNESS 0.127 / 0.005 0.127 / 0.005 FACE AREA m 2 /ft 2 2.29 / 24.72 2.29 / 24.72 1 20 16 WIDTH 665 / 26.1 780 / 30.7 HEIGHT 345 / 13.9 345 / 13.9 QUANTITY pc 2 INDOOR UNIT ROW OUTDOOR UNIT FIN PER INCH FINSIHING COLOUR FINISHING COLOUR CENTRIFUGAL INDUCTION PROPELLER 1 ALUMINIUM DIRECT 812.8 / 32.0 INDUCTION 1 SCROLL WASHABLE SARANET FILTER GALVANIZED MILD STEEL - - ELECTRO GALVANIZED STEEL EPOXY POLYESTER POWDER WHITE 2 1 4 2 2 17

General Data - Heat pump (R407C) MODEL NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY INDOOR UNIT Btu/h Btu/h ACC 75DR 75000 84000 ACC 100DR 100000 110000 OUTDOOR UNIT W W A4MC 75ER 21980 24620 A4MC 100ER 29310 32240 NOMINAL TOTAL INPUT POWER (COOLING) W 7827 11040 NOMINAL TOTAL INPUT POWER (HEATING) W 7827 9279 NOMINAL RUNNING CURRENT (COOLING) A 13.9 19.0 NOMINAL RUNNING CURRENT (HEATING) A 13.9 19.6 POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 REFRIGERANT / CONTROL R407C / INDOOR & OUTDOOR TXV SUPER HIGH CFM / L/s 2520 / 1189 3070 / 1449 AIR FLOW HIGH CFM / L/s 2320 / 1095 2620 / 1237 MEDIUM CFM / L/s 2095 / 989 2350 / 1109 LOW CFM / L/s 1660 / 783 2150 / 1015 EXTERNAL STATIC PRESSURE (SH/H/M/L) mmaq(pa) 20 / 14 / 10 / 7 (196 / 137 / 98 / 69) INDOOR UNIT OUTDOOR UNIT SOUND PRESSURE LEVEL (SH/H/M/L) dba 52 / 52 / 48 / 43 55 / 54 / 52 / 48 HEIGHT 430 / 16.9 430 / 16.9 UNIT DIMENSION WIDTH 1426 / 56.1 1655 / 65.2 DEPTH 826 / 32.5 826 / 32.5 HEIGHT 612 / 24.1 612 / 24.1 PACKING DIMENSION WIDTH 1535 / 60.4 1765 / 69.5 DEPTH 974 / 38.3 974 / 38.3 UNIT WEIGHT kg/lb 92 / 203 119 / 262 CONDENSATE DRAIN SIZE 25.4 / 1.0 25.4 / 1.0 AIR FLOW SOUND PRESSURE LEVEL CFM / L/s dba 7000 / 3304 64 UNIT DIMENSION PACKING DIMENSION HEIGHT WIDTH DEPTH HEIGHT WIDTH DEPTH 1041 / 40.98 981 / 38.62 981 / 38.62 1224 / 48.2 1175 / 46.3 1150 / 45.3 UNIT WEIGHT kg/lb 170 / 374 184 / 405 BRAZING PIPE CONNECTION LIQUID 12.70 / 1/2 15.88 / 5/8 SIZE GAS 28.58 / 1-1/8 28.58 / 1-1/8 REFRIGERANT CHARGE kg/lb 7.00 / 15.43 7.80 / 17.20 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI 210/240-94. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 26.7 C DB / 19.4 C WB INDOOR AND 35.0 C DB / 23.9 C WB OUTDOOR b) HEATING - 21.1 C DB INDOOR AND 8.3 C DB / 6.1 C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT. 18

Electrical Data - Heat pump (R407C) MODEL INDOOR UNIT ACC 75DR ACC 100DR OUTDOOR UNIT A4MC 75ER A4MC 100ER INDUCTION INSULATION GRADE CLASS B POWER SOURCE V/Ph/Hz 220-240 / 1 / 50 INDOOR MOTOR RATED INPUT POWER W 1061 1254 RATED RUNNING CURRENT A 4.51 5.79 MOTOR OUTPUT W 750 1000 POLES 4 4 INDUCTION INSULATION GRADE CLASS F OUTDOOR MOTOR POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 RATED INPUT POWER W 600 RATED RUNNING CURRENT A 1.2 MOTOR OUTPUT W 350 SCROLL INSULATION GRADE N/A N/A POWER SOURCE V/Ph/Hz 380-415 / 3 / 50 CAPACITOR µf NIL NIL COMPRESSOR RATED INPUT POWER (COOLING) W 6045 9186 RATED INPUT POWER (HEATING) W 6045 7425 RATED RUNNING CURRENT (COOLING) A 11.1 15.9 RATED RUNNING CURRENT (HEATING) A 11.1 16.5 LOCKED ROTOR AMP. A 95 125 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI210/240-94. 19

Components Data (R407C) MODEL INDOOR FAN INDOOR FAN MOTOR OUTDOOR FAN OUTDOOR FAN MOTOR COMPRESSOR INDOOR COIL OUTDOOR COIL FILTRATION CASING INDOOR UNIT OUTDOOR UNIT Q'TY DRIVE DIAMETER LENGTH Q'TY INDEX OF PROTECTION (IP) Q'TY DRIVE DIAMETER Q'TY INDEX OF PROTECTION (IP) OIL ACC 75DR A4MC 75ER 2 ZINC COATED STEEL DIRECT ACC 100DR A4MC 100ER ZINC COATED STEEL DIRECT 228.6 / 9.0 228.6 / 9.0 177.8 / 7.0 228.6 / 9.0 1 N/A N/A SONTEX 200 LT N/A N/A SONTEX 200 LT OIL AMOUNT cm 3 2513 3253 TUBE FIN TUBE FIN SIZE S. I. G. C. SEAMLESS COPPER DIAMETER 9.52 / 3/8 9.52 / 3/8 THICKNESS 0.35 / 0.013 0.35 / 0.013 ALUMINIUM ALUMINIUM THICKNESS 0.127 / 0.005 0.127 / 0.005 FACE AREA m 2 /ft 2 0.45 / 4.89 0.55 / 5.89 4 12 14 S. I. G. C. SEAMLESS COPPER DIAMETER 9.52 / 3/8 9.52 / 3/8 THICKNESS 0.35 / 0.013 0.35 / 0.013 ALUMINIUM ALUMINIUM THICKNESS 0.127 / 0.005 0.127 / 0.005 FACE AREA m 2 /ft 2 2.29 / 24.72 2.29 / 24.72 1 20 16 WIDTH 665 / 26.1 780 / 30.7 HEIGHT 345 / 13.9 345 / 13.9 QUANTITY pc 2 INDOOR UNIT ROW OUTDOOR UNIT FIN PER INCH ROW FIN PER INCH FINSIHING COLOUR FINISHING COLOUR CENTRIFUGAL INDUCTION PROPELLER 1 ALUMINIUM DIRECT 812.8 / 32.0 INDUCTION 1 SCROLL WASHABLE SARANET FILTER GALVANIZED MILD STEEL - - ELECTRO GALVANIZED STEEL EPOXY POLYESTER POWDER WHITE 2 1 4 2 2 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 20

Safety Devices MODEL SAFETY DEVICE INDOOR UNIT ACC 75D ACC 100D OUTDOOR UNIT A4MC 75D A4MC 100D HIGH PRESSURE SWITCH LOW PRESSURE SWITCH AUTO RESET AUTO RESET AUTO RESET AUTO RESET SETTING SETTING 426 psi OFF 18 psi OFF 426 psi OFF 18 psi OFF PHASE SEQUENCER AVAILABLE AVAILABLE DISCHARGE THERMOSTAT SETTING 130 o C 130 o C 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. MODEL SAFETY DEVICE INDOOR UNIT ACC 75DR ACC 100DR OUTDOOR UNIT A4MC 75ER A4MC 100ER HIGH PRESSURE SWITCH LOW PRESSURE SWITCH AUTO RESET AUTO RESET AUTO RESET AUTO RESET SETTING SETTING 426 psi OFF 7 psi OFF 426 psi OFF 7 psi OFF PHASE SEQUENCER AVAILABLE AVAILABLE DISCHARGE THERMOSTAT SETTING 130 o C 130 o C 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 21

5. OPERATING RANGE Ensure the operating temperature is in allowable range. Cooling only Outdoor temp. ( CDB) 54 46 35 19 High ambient unit Standard point Low ambient kit Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. -5 15 24 Indoor temp. ( CWB) Heatpump Heating Cooling Outdoor temp. ( CWB) 18 6 Standard point Outdoor temp. ( CDB) 54 46 35 19 High ambient unit Standard point Low ambient kit -9-5 15 21 Indoor temp. ( CDB) 27 15 24 Indoor temp. ( CWB) Note : Standard operating range. With High ambient unit. (Optional item) Please refer to local dealer for unit of this specification. With Low ambient kit. (Optional item) Please refer to local dealer for unit of this specification. 22

6. SOUND DATA ACC 75D/DR Ext. Static Speed 1/1 Octave sound Pressure Level (db, reference 20Pa) Overall Noise (mmaq) 125 250 500 1000 2000 4000 8000 (dba) Criteria 20 SH 52 49 49 48 45 40 33 52 47 14 Hi 51 49 48 47 44 40 33 52 46 10 Me 48 46 46 45 40 34 26 48 44 7 Lo 43 40 42 38 36 30 19 43 37 ACC 100D/DR Ext. Static Speed 1/1 Octave sound Pressure Level (db, reference 20Pa) Overall Noise (mmaq) 125 250 500 1000 2000 4000 8000 (dba) Criteria 20 SH 60 54 51 51 49 44 37 55 50 14 Hi 59 52 50 50 48 42 36 54 49 10 Me 55 51 49 47 44 38 31 52 46 7 Lo 55 47 47 43 40 33 26 48 43 Microphone position: 1.4m below the centre of the unit. (Tested with 2m length duct at the air discharge outlet and air return inlet) 23

NC CURVES 70 ACC 75D/DR NC CURVES 60 Sound Pressure Level (db, ref 20µPa) 50 40 30 20 SH FAN HI FAN ME FAN LO FAN NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) 70 ACC 100D/DR NC CURVES 60 SH FAN Sound Pressure Level (db, ref 20µPa) 50 40 30 20 HI FAN ME FAN LO FAN NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 10 0 125 250 500 1000 2000 4000 8000 Octave-band Frequency (Hz) 24

5. 7. PERFORMANCE TABLE Interpolation and Extrapolation method can be used to get the total capacity, TC and sensible capacity, SC at those temperatures which are not stated out in the table. Example: Model: ACC 75D AMC 75D Indoor Condition: 23 C DB, 15 C WB Outdoor Condition: 37 C DB Solution: Overall Based on the Performance table on Pg. 29, 1. Refer to the Indoor DB column, - 23 C is located between 20 C and 24 C (Thus, Interpolation need to be applied) 2. Refer to the Indoor WB column, - 15 C only available in the case of Indoor DB = 20 C. (Thus, Extrapolation between 16 C WB and 17 C WB during 24 C indoor DB is required) 3. Refer to the Outdoor DB column, - 37 C is located between 35 C and 40 C. (Thus, Interpolation need to be applied) Please follow the steps below in order to get the required capacity. 1 st Step Extrapolation of Indoor WB Find TC, SC for (a) Indoor: 24 C DB, 15 C WB Outdoor: 35 C DB (b) Indoor: 24 C DB, 15 C WB Outdoor: 40 C DB 2 nd Step Interpolation of Indoor DB Find TC, SC for (a) Indoor: 23 C DB, 15 C WB Outdoor: 35 C DB (b) Indoor: 23 C DB, 15 C WB Outdoor: 40 C DB 3 rd Step Interpolation of Outdoor DB Find TC, SC for (a) Indoor: 23 C DB, 15 C WB Outdoor: 37 C DB 25

Details: 1 st Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 24 C DB, 15 C WB Outdoor Condition: 35 C DB Indoor DB C Outdoor DB, C Indoor WB 35 C TC (kw) SC (kw) 24 15 x 1 y 1 16 20.229 15.040 17 20.744 14.517 Total capacity, TC x 1 = 19.713kW (Same as Total capacity at 20 C Indoor DB / 15 C Indoor WB & 35 C Outdoor WB)* Sensible capacity, SC Extrapolation Method: 17 C - 15 C 14.517kW - y1 17 C - 16 C 14.517kW - 15.040kW y 1 = 15.563kW (b) Indoor Condition: 24 C DB, 15 C WB Outdoor Condition: 40 C DB Indoor DB C Outdoor DB, C Indoor WB 40 C TC (kw) SC (kw) 24 15 x 2 y 2 16 18.776 13.808 17 19.366 13.463 Total capacity, TC x 2 = 18.186kW (Same as Total capacity at 20 C Indoor DB / 15 C Indoor WB & 40 C Outdoor WB)* Sensible capacity, SC Extrapolation Method: 17 C - 15 C 13.463kW - y 2 17 C - 16 C 13.463kW - 13.808kW y 2 = 14.153kW * This is due to 2 different conditions with same WB temperature, will have the same level of enthalpy. For more details, please refer to psychrometrics chart 26

2 nd Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23 C DB, 15 C WB Outdoor Condition: 35 C DB Indoor DB C Outdoor DB, C Indoor WB 35 C TC (kw) SC (kw) 20 15 19.173 11.110 23 15 x 3 y 3 24 15 19.173 15.563 Total capacity, TC x 3 = 19.173kW (Same as Total capacity at 20 C Indoor DB / 15 C Indoor WB & 35 C Outdoor WB)* Sensible capacity, SC Interpolation Method: 24 C - 20 C 15.563kW - 11.110kW 24 C - 23 C 15.563kW - y 3 = 14.450kW y 3 (b) Indoor Condition: 23 C DB, 15 C WB Outdoor Condition: 40 C DB Indoor DB C Outdoor DB, C Indoor WB 40 C TC (kw) SC (kw) 20 15 18.186 9.698 23 15 x 4 y 4 24 15 18.186 14.153 Total capacity, TC x 4 = 18.186kW (Same as Total capacity at 20 C Indoor DB / 15 C Indoor WB & 40 C Outdoor WB)* Sensible capacity, SC Interpolation Method: 24 C - 20 C 14.153kW - 9.698kW 24 C - 23C 14.153kW - y 4 = 13.039kW y 1 * This is due to 2 different conditions with same WB temperature will have the same level of enthalpy. For more details, please refer to psychrometrics chart 27

3 rd Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23 C DB, 15 C WB Outdoor Condition: 37 C DB Indoor DB C Outdoor DB, C Indoor WB 35 37 40 C TC (kw) SC (kw) TC (kw) SC (kw) TC (kw) SC (kw) 23 15 19.713 14.450 x y 18.186 13.039 Total capacity, TC Interpolation Method: 40 C - 35 C 18.186kW - 19.713kW 40 C - 37 C 18.186kW - x x = 19.102kW Sensible capacity, SC Interpolation Method: 40 C - 35 C 13.039kW - 14.450kW 40 C - 37 C 13.039kW - y y = 13.886kW 28

R22 MODELS (COOLING ONLY) MODEL : ACC 75D / AMC 75D Outdoor DB C ID DB C ID WB C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 15 24.294 15.345 22.767 13.934 21.240 12.522 19.713 11.110 18.186 9.698 16.354 8.004 16 24.586 14.284 23.133 13.052 21.681 11.819 20.229 10.587 18.776 9.354 17.033 7.875 16 24.586 18.738 23.133 17.505 21.681 16.273 20.229 15.040 18.776 13.808 17.033 12.329 17 24.877 17.677 23.500 16.623 22.122 15.570 20.744 14.517 19.366 13.463 17.713 12.199 24 18 25.169 16.616 23.866 15.742 22.563 14.867 21.260 13.993 19.956 13.119 18.392 12.070 19 25.461 15.555 24.233 14.860 23.004 14.164 21.775 13.469 20.546 12.774 19.072 11.940 20 25.750 14.484 24.572 13.887 23.393 13.290 22.215 12.693 21.036 12.096 19.622 11.380 18 25.169 21.069 23.866 20.195 22.563 19.321 21.260 18.447 19.956 17.572 18.392 16.523 19 25.461 20.008 24.233 19.313 23.004 18.618 21.775 17.923 20.546 17.228 19.072 16.394 20 25.750 18.938 24.572 18.341 23.393 17.744 22.215 17.147 21.036 16.550 19.622 15.833 28 21 26.038 17.860 24.893 17.308 23.748 16.755 22.603 16.202 21.459 15.649 20.085 14.986 22 26.325 16.783 25.214 16.274 24.103 15.766 22.992 15.257 21.882 14.749 20.549 14.138 23 26.612 15.706 25.535 15.241 24.458 14.777 23.381 14.313 22.304 13.848 21.012 13.291 24 26.899 14.629 25.856 14.208 24.813 13.788 23.770 13.368 22.727 12.948 21.476 12.443 20 25.750 21.164 24.572 20.567 23.393 19.971 22.215 19.374 21.036 18.777 19.622 18.060 21 26.038 20.087 24.893 19.534 23.748 18.982 22.603 18.429 21.459 17.876 20.085 17.213 30 22 26.325 19.010 25.214 18.501 24.103 17.993 22.992 17.484 21.882 16.976 20.549 16.365 23 26.612 17.933 25.535 17.468 24.458 17.004 23.381 16.539 22.304 16.075 21.012 15.518 24 26.899 16.855 25.856 16.435 24.813 16.015 23.770 15.595 22.727 15.174 21.476 14.670 MODEL : ACC 100D / AMC 100D Outdoor DB C ID DB C ID WB C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 15 30.592 19.623 28.908 18.136 27.224 16.650 25.540 15.163 23.856 13.676 21.835 11.892 16 31.345 18.451 29.695 17.179 28.046 15.906 26.396 14.634 24.747 13.362 22.767 11.835 16 31.345 23.736 29.695 22.464 28.046 21.192 26.396 19.919 24.747 18.647 22.767 17.120 17 32.098 22.565 30.483 21.507 28.868 20.448 27.253 19.390 25.638 18.332 23.700 17.062 24 18 32.851 21.393 31.270 20.549 29.690 19.705 28.109 18.861 26.529 18.017 24.632 17.004 19 33.603 20.222 32.057 19.592 30.512 18.962 28.966 18.332 27.420 17.702 25.565 16.946 20 34.351 19.034 32.801 18.482 31.251 17.930 29.700 17.378 28.150 16.825 26.290 16.163 18 32.851 26.679 31.270 25.835 29.690 24.991 28.109 24.146 26.529 23.302 24.632 22.290 19 33.603 25.507 32.057 24.877 30.512 24.247 28.966 23.617 27.420 22.988 25.565 22.232 20 34.351 24.319 32.801 23.767 31.251 23.215 29.700 22.663 28.150 22.111 26.290 21.448 28 21 35.096 23.120 33.515 22.555 31.935 21.990 30.354 21.425 28.773 20.859 26.876 20.181 22 35.841 21.922 34.230 21.343 32.618 20.765 31.007 20.186 29.396 19.608 27.462 18.914 23 36.586 20.723 34.944 20.131 33.302 19.539 31.660 18.948 30.018 18.356 28.048 17.646 24 37.331 19.524 35.659 18.919 33.986 18.314 32.314 17.709 30.641 17.105 28.634 16.379 20 34.351 26.962 32.801 26.410 31.251 25.858 29.700 25.306 28.150 24.753 26.290 24.091 21 35.096 25.763 33.515 25.198 31.935 24.632 30.354 24.067 28.773 23.502 26.876 22.824 30 22 35.841 24.564 34.230 23.986 32.618 23.407 31.007 22.829 29.396 22.250 27.462 21.556 23 36.586 23.365 34.944 22.774 33.302 22.182 31.660 21.590 30.018 20.999 28.048 20.289 24 37.331 22.166 35.659 21.562 33.986 20.957 32.314 20.352 30.641 19.747 28.634 19.022 29

R22 MODELS (HEATPUMP) MODEL : ACC 75DR / AMC 75ER COOLING MODE Outdoor DB C ID DB C ID WB C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 15 24.294 15.345 22.767 13.934 21.240 12.522 19.713 11.110 18.186 9.698 16.354 8.004 16 24.586 14.284 23.133 13.052 21.681 11.819 20.229 10.587 18.776 9.354 17.033 7.875 16 24.586 18.738 23.133 17.505 21.681 16.273 20.229 15.040 18.776 13.808 17.033 12.329 17 24.877 17.677 23.500 16.623 22.122 15.570 20.744 14.517 19.366 13.463 17.713 12.199 24 18 25.169 16.616 23.866 15.742 22.563 14.867 21.260 13.993 19.956 13.119 18.392 12.070 19 25.461 15.555 24.233 14.860 23.004 14.164 21.775 13.469 20.546 12.774 19.072 11.940 20 25.750 14.484 24.572 13.887 23.393 13.290 22.215 12.693 21.036 12.096 19.622 11.380 18 25.169 21.069 23.866 20.195 22.563 19.321 21.260 18.447 19.956 17.572 18.392 16.523 19 25.461 20.008 24.233 19.313 23.004 18.618 21.775 17.923 20.546 17.228 19.072 16.394 20 25.750 18.938 24.572 18.341 23.393 17.744 22.215 17.147 21.036 16.550 19.622 15.833 28 21 26.038 17.860 24.893 17.308 23.748 16.755 22.603 16.202 21.459 15.649 20.085 14.986 22 26.325 16.783 25.214 16.274 24.103 15.766 22.992 15.257 21.882 14.749 20.549 14.138 23 26.612 15.706 25.535 15.241 24.458 14.777 23.381 14.313 22.304 13.848 21.012 13.291 24 26.899 14.629 25.856 14.208 24.813 13.788 23.770 13.368 22.727 12.948 21.476 12.443 20 25.750 21.164 24.572 20.567 23.393 19.971 22.215 19.374 21.036 18.777 19.622 18.060 21 26.038 20.087 24.893 19.534 23.748 18.982 22.603 18.429 21.459 17.876 20.085 17.213 30 22 26.325 19.010 25.214 18.501 24.103 17.993 22.992 17.484 21.882 16.976 20.549 16.365 23 26.612 17.933 25.535 17.468 24.458 17.004 23.381 16.539 22.304 16.075 21.012 15.518 24 26.899 16.855 25.856 16.435 24.813 16.015 23.770 15.595 22.727 15.174 21.476 14.670 HEATING MODE Outdoor WB C ID DB C -9-6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 15.812 15.812 17.812 17.812 18.478 18.478 25.812 25.812 29.812 29.812 31.812 31.812 33.812 33.812 17 15.621 15.621 17.640 17.640 18.313 18.313 25.414 25.414 29.546 29.546 31.529 31.529 33.511 33.511 19 15.431 15.431 17.468 17.468 18.147 18.147 25.017 25.017 29.280 29.280 31.245 31.245 33.210 33.210 21 15.240 15.240 17.296 17.296 17.981 17.981 24.619 24.619 29.014 29.014 30.961 30.961 32.908 32.908 23 15.149 15.149 17.149 17.149 17.816 17.816 24.564 24.564 28.748 28.748 30.678 30.678 32.607 32.607 25 15.058 15.058 17.002 17.002 17.650 17.650 24.510 24.510 28.482 28.482 30.394 30.394 32.306 32.306 27 14.967 14.967 16.855 16.855 17.485 17.485 24.455 24.455 28.217 28.217 30.110 30.110 32.004 32.004 FROST REGION 30

R22 MODELS (HEATPUMP) MODEL : ACC 100D / AMC 100ER COOLING MODE Outdoor DB C ID DB C ID WB C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 15 30.592 19.623 28.908 18.136 27.224 16.650 25.540 15.163 23.856 13.676 21.835 11.892 16 31.345 18.451 29.695 17.179 28.046 15.906 26.396 14.634 24.747 13.362 22.767 11.835 16 31.345 23.736 29.695 22.464 28.046 21.192 26.396 19.919 24.747 18.647 22.767 17.120 17 32.098 22.565 30.483 21.507 28.868 20.448 27.253 19.390 25.638 18.332 23.700 17.062 24 18 32.851 21.393 31.270 20.549 29.690 19.705 28.109 18.861 26.529 18.017 24.632 17.004 19 33.603 20.222 32.057 19.592 30.512 18.962 28.966 18.332 27.420 17.702 25.565 16.946 20 34.351 19.034 32.801 18.482 31.251 17.930 29.700 17.378 28.150 16.825 26.290 16.163 18 32.851 26.679 31.270 25.835 29.690 24.991 28.109 24.146 26.529 23.302 24.632 22.290 19 33.603 25.507 32.057 24.877 30.512 24.247 28.966 23.617 27.420 22.988 25.565 22.232 20 34.351 24.319 32.801 23.767 31.251 23.215 29.700 22.663 28.150 22.111 26.290 21.448 28 21 35.096 23.120 33.515 22.555 31.935 21.990 30.354 21.425 28.773 20.859 26.876 20.181 22 35.841 21.922 34.230 21.343 32.618 20.765 31.007 20.186 29.396 19.608 27.462 18.914 23 36.586 20.723 34.944 20.131 33.302 19.539 31.660 18.948 30.018 18.356 28.048 17.646 24 37.331 19.524 35.659 18.919 33.986 18.314 32.314 17.709 30.641 17.105 28.634 16.379 20 34.351 26.962 32.801 26.410 31.251 25.858 29.700 25.306 28.150 24.753 26.290 24.091 21 35.096 25.763 33.515 25.198 31.935 24.632 30.354 24.067 28.773 23.502 26.876 22.824 30 22 35.841 24.564 34.230 23.986 32.618 23.407 31.007 22.829 29.396 22.250 27.462 21.556 23 36.586 23.365 34.944 22.774 33.302 22.182 31.660 21.590 30.018 20.999 28.048 20.289 24 37.331 22.166 35.659 21.562 33.986 20.957 32.314 20.352 30.641 19.747 28.634 19.022 HEATING MODE Outdoor WB C ID DB C -9-6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 23.133 23.133 24.838 24.838 25.406 25.406 31.659 31.659 35.069 35.069 36.775 36.775 38.480 38.480 17 23.140 23.140 24.669 24.669 25.178 25.178 31.852 31.852 34.756 34.756 36.447 36.447 38.137 38.137 19 23.147 23.147 24.500 24.500 24.951 24.951 32.046 32.046 34.444 34.444 36.119 36.119 37.794 37.794 21 23.154 23.154 24.330 24.330 24.723 24.723 32.239 32.239 34.131 34.131 35.791 35.791 37.451 37.451 23 22.720 22.720 24.051 24.051 24.495 24.495 31.455 31.455 33.818 33.818 35.463 35.463 37.108 37.108 25 22.285 22.285 23.772 23.772 24.267 24.267 30.670 30.670 33.505 33.505 35.135 35.135 36.765 36.765 27 21.851 21.851 23.492 23.492 24.039 24.039 29.886 29.886 33.192 33.192 34.807 34.807 36.422 36.422 FROST REGION 31

R407C MODELS (COOLING ONLY) MODEL : ACC 75D / A4MC 75D Outdoor DB C ID DB C ID WB C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 15 24.294 15.345 22.767 13.934 21.240 12.522 19.713 11.110 18.186 9.698 16.354 8.004 16 24.586 14.284 23.133 13.052 21.681 11.819 20.229 10.587 18.776 9.354 17.033 7.875 16 24.586 18.738 23.133 17.505 21.681 16.273 20.229 15.040 18.776 13.808 17.033 12.329 17 24.877 17.677 23.500 16.623 22.122 15.570 20.744 14.517 19.366 13.463 17.713 12.199 24 18 25.169 16.616 23.866 15.742 22.563 14.867 21.260 13.993 19.956 13.119 18.392 12.070 19 25.461 15.555 24.233 14.860 23.004 14.164 21.775 13.469 20.546 12.774 19.072 11.940 20 25.750 14.484 24.572 13.887 23.393 13.290 22.215 12.693 21.036 12.096 19.622 11.380 18 25.169 21.069 23.866 20.195 22.563 19.321 21.260 18.447 19.956 17.572 18.392 16.523 19 25.461 20.008 24.233 19.313 23.004 18.618 21.775 17.923 20.546 17.228 19.072 16.394 20 25.750 18.938 24.572 18.341 23.393 17.744 22.215 17.147 21.036 16.550 19.622 15.833 28 21 26.038 17.860 24.893 17.308 23.748 16.755 22.603 16.202 21.459 15.649 20.085 14.986 22 26.325 16.783 25.214 16.274 24.103 15.766 22.992 15.257 21.882 14.749 20.549 14.138 23 26.612 15.706 25.535 15.241 24.458 14.777 23.381 14.313 22.304 13.848 21.012 13.291 24 26.899 14.629 25.856 14.208 24.813 13.788 23.770 13.368 22.727 12.948 21.476 12.443 20 25.750 21.164 24.572 20.567 23.393 19.971 22.215 19.374 21.036 18.777 19.622 18.060 21 26.038 20.087 24.893 19.534 23.748 18.982 22.603 18.429 21.459 17.876 20.085 17.213 30 22 26.325 19.010 25.214 18.501 24.103 17.993 22.992 17.484 21.882 16.976 20.549 16.365 23 26.612 17.933 25.535 17.468 24.458 17.004 23.381 16.539 22.304 16.075 21.012 15.518 24 26.899 16.855 25.856 16.435 24.813 16.015 23.770 15.595 22.727 15.174 21.476 14.670 MODEL : ACC 100D / A4MC 100D Outdoor DB C ID DB C ID WB C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 15 30.592 19.623 28.908 18.136 27.224 16.650 25.540 15.163 23.856 13.676 21.835 11.892 16 31.345 18.451 29.695 17.179 28.046 15.906 26.396 14.634 24.747 13.362 22.767 11.835 16 31.345 23.736 29.695 22.464 28.046 21.192 26.396 19.919 24.747 18.647 22.767 17.120 17 32.098 22.565 30.483 21.507 28.868 20.448 27.253 19.390 25.638 18.332 23.700 17.062 24 18 32.851 21.393 31.270 20.549 29.690 19.705 28.109 18.861 26.529 18.017 24.632 17.004 19 33.603 20.222 32.057 19.592 30.512 18.962 28.966 18.332 27.420 17.702 25.565 16.946 20 34.351 19.034 32.801 18.482 31.251 17.930 29.700 17.378 28.150 16.825 26.290 16.163 18 32.851 26.679 31.270 25.835 29.690 24.991 28.109 24.146 26.529 23.302 24.632 22.290 19 33.603 25.507 32.057 24.877 30.512 24.247 28.966 23.617 27.420 22.988 25.565 22.232 20 34.351 24.319 32.801 23.767 31.251 23.215 29.700 22.663 28.150 22.111 26.290 21.448 28 21 35.096 23.120 33.515 22.555 31.935 21.990 30.354 21.425 28.773 20.859 26.876 20.181 22 35.841 21.922 34.230 21.343 32.618 20.765 31.007 20.186 29.396 19.608 27.462 18.914 23 36.586 20.723 34.944 20.131 33.302 19.539 31.660 18.948 30.018 18.356 28.048 17.646 24 37.331 19.524 35.659 18.919 33.986 18.314 32.314 17.709 30.641 17.105 28.634 16.379 20 34.351 26.962 32.801 26.410 31.251 25.858 29.700 25.306 28.150 24.753 26.290 24.091 21 35.096 25.763 33.515 25.198 31.935 24.632 30.354 24.067 28.773 23.502 26.876 22.824 30 22 35.841 24.564 34.230 23.986 32.618 23.407 31.007 22.829 29.396 22.250 27.462 21.556 23 36.586 23.365 34.944 22.774 33.302 22.182 31.660 21.590 30.018 20.999 28.048 20.289 24 37.331 22.166 35.659 21.562 33.986 20.957 32.314 20.352 30.641 19.747 28.634 19.022 32

R407C MODELS (HEATPUMP) MODEL : ACC 75DR / A4MC 75ER COOLING MODE Outdoor DB C ID DB C ID WB C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 15 24.294 15.345 22.767 13.934 21.240 12.522 19.713 11.110 18.186 9.698 16.354 8.004 16 24.586 14.284 23.133 13.052 21.681 11.819 20.229 10.587 18.776 9.354 17.033 7.875 16 24.586 18.738 23.133 17.505 21.681 16.273 20.229 15.040 18.776 13.808 17.033 12.329 17 24.877 17.677 23.500 16.623 22.122 15.570 20.744 14.517 19.366 13.463 17.713 12.199 24 18 25.169 16.616 23.866 15.742 22.563 14.867 21.260 13.993 19.956 13.119 18.392 12.070 19 25.461 15.555 24.233 14.860 23.004 14.164 21.775 13.469 20.546 12.774 19.072 11.940 20 25.750 14.484 24.572 13.887 23.393 13.290 22.215 12.693 21.036 12.096 19.622 11.380 18 25.169 21.069 23.866 20.195 22.563 19.321 21.260 18.447 19.956 17.572 18.392 16.523 19 25.461 20.008 24.233 19.313 23.004 18.618 21.775 17.923 20.546 17.228 19.072 16.394 20 25.750 18.938 24.572 18.341 23.393 17.744 22.215 17.147 21.036 16.550 19.622 15.833 28 21 26.038 17.860 24.893 17.308 23.748 16.755 22.603 16.202 21.459 15.649 20.085 14.986 22 26.325 16.783 25.214 16.274 24.103 15.766 22.992 15.257 21.882 14.749 20.549 14.138 23 26.612 15.706 25.535 15.241 24.458 14.777 23.381 14.313 22.304 13.848 21.012 13.291 24 26.899 14.629 25.856 14.208 24.813 13.788 23.770 13.368 22.727 12.948 21.476 12.443 20 25.750 21.164 24.572 20.567 23.393 19.971 22.215 19.374 21.036 18.777 19.622 18.060 21 26.038 20.087 24.893 19.534 23.748 18.982 22.603 18.429 21.459 17.876 20.085 17.213 30 22 26.325 19.010 25.214 18.501 24.103 17.993 22.992 17.484 21.882 16.976 20.549 16.365 23 26.612 17.933 25.535 17.468 24.458 17.004 23.381 16.539 22.304 16.075 21.012 15.518 24 26.899 16.855 25.856 16.435 24.813 16.015 23.770 15.595 22.727 15.174 21.476 14.670 HEATING MODE Outdoor WB C ID DB C -9-6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 15.812 15.812 17.812 17.812 18.478 18.478 25.812 25.812 29.812 29.812 31.812 31.812 33.812 33.812 17 15.621 15.621 17.640 17.640 18.313 18.313 25.414 25.414 29.546 29.546 31.529 31.529 33.511 33.511 19 15.431 15.431 17.468 17.468 18.147 18.147 25.017 25.017 29.280 29.280 31.245 31.245 33.210 33.210 21 15.240 15.240 17.296 17.296 17.981 17.981 24.619 24.619 29.014 29.014 30.961 30.961 32.908 32.908 23 15.149 15.149 17.149 17.149 17.816 17.816 24.564 24.564 28.748 28.748 30.678 30.678 32.607 32.607 25 15.058 15.058 17.002 17.002 17.650 17.650 24.510 24.510 28.482 28.482 30.394 30.394 32.306 32.306 27 14.967 14.967 16.855 16.855 17.485 17.485 24.455 24.455 28.217 28.217 30.110 30.110 32.004 32.004 FROST REGION 33

R407C MODELS (HEATPUMP) MODEL : ACC 100D / A4MC 100ER COOLING MODE Outdoor DB C ID DB C ID WB C 20 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 20 15 30.592 19.623 28.908 18.136 27.224 16.650 25.540 15.163 23.856 13.676 21.835 11.892 16 31.345 18.451 29.695 17.179 28.046 15.906 26.396 14.634 24.747 13.362 22.767 11.835 16 31.345 23.736 29.695 22.464 28.046 21.192 26.396 19.919 24.747 18.647 22.767 17.120 17 32.098 22.565 30.483 21.507 28.868 20.448 27.253 19.390 25.638 18.332 23.700 17.062 24 18 32.851 21.393 31.270 20.549 29.690 19.705 28.109 18.861 26.529 18.017 24.632 17.004 19 33.603 20.222 32.057 19.592 30.512 18.962 28.966 18.332 27.420 17.702 25.565 16.946 20 34.351 19.034 32.801 18.482 31.251 17.930 29.700 17.378 28.150 16.825 26.290 16.163 18 32.851 26.679 31.270 25.835 29.690 24.991 28.109 24.146 26.529 23.302 24.632 22.290 19 33.603 25.507 32.057 24.877 30.512 24.247 28.966 23.617 27.420 22.988 25.565 22.232 20 34.351 24.319 32.801 23.767 31.251 23.215 29.700 22.663 28.150 22.111 26.290 21.448 28 21 35.096 23.120 33.515 22.555 31.935 21.990 30.354 21.425 28.773 20.859 26.876 20.181 22 35.841 21.922 34.230 21.343 32.618 20.765 31.007 20.186 29.396 19.608 27.462 18.914 23 36.586 20.723 34.944 20.131 33.302 19.539 31.660 18.948 30.018 18.356 28.048 17.646 24 37.331 19.524 35.659 18.919 33.986 18.314 32.314 17.709 30.641 17.105 28.634 16.379 20 34.351 26.962 32.801 26.410 31.251 25.858 29.700 25.306 28.150 24.753 26.290 24.091 21 35.096 25.763 33.515 25.198 31.935 24.632 30.354 24.067 28.773 23.502 26.876 22.824 30 22 35.841 24.564 34.230 23.986 32.618 23.407 31.007 22.829 29.396 22.250 27.462 21.556 23 36.586 23.365 34.944 22.774 33.302 22.182 31.660 21.590 30.018 20.999 28.048 20.289 24 37.331 22.166 35.659 21.562 33.986 20.957 32.314 20.352 30.641 19.747 28.634 19.022 HEATING MODE Outdoor WB C ID DB C -9-6 -5 6 12 15 18 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 15 23.133 23.133 24.838 24.838 25.406 25.406 31.659 31.659 35.069 35.069 36.775 36.775 38.480 38.480 17 23.140 23.140 24.669 24.669 25.178 25.178 31.852 31.852 34.756 34.756 36.447 36.447 38.137 38.137 19 23.147 23.147 24.500 24.500 24.951 24.951 32.046 32.046 34.444 34.444 36.119 36.119 37.794 37.794 21 23.154 23.154 24.330 24.330 24.723 24.723 32.239 32.239 34.131 34.131 35.791 35.791 37.451 37.451 23 22.720 22.720 24.051 24.051 24.495 24.495 31.455 31.455 33.818 33.818 35.463 35.463 37.108 37.108 25 22.285 22.285 23.772 23.772 24.267 24.267 30.670 30.670 33.505 33.505 35.135 35.135 36.765 36.765 27 21.851 21.851 23.492 23.492 24.039 24.039 29.886 29.886 33.192 33.192 34.807 34.807 36.422 36.422 FROST REGION 34

8. OUTLINES AND DIMENSIONS INDOOR UNIT MODEL : ACC 75D/DR MODEL : ACC 100D/DR Note: Dimension in mm 35 Note: Dimension in mm

OUTDOOR UNIT MODEL : AMC / A4MC 75 / 100 D/ER Note: Dimension in mm 36

. 9. REFRIGERANT CIRCUIT MODEL : ACC 75/100D - AMC / A4MC 75/100D MODEL : ACC 75/100DR - AMC / A4MC 75/100ER 37

10. WIRING DIAGRAMS COOLING UNIT MODEL : ACC 75/100D - AMC / A4MC 75/100D 38

MODEL : ACC 75/100DR - AMC / A4MC 75/100ER 39

11. INSTALLATION PRELIMINARY SITE SURVEY Electrical supply and installation is to conform to local authority's codes and regulations. (e.g. National Electricity Board). Voltage supply fluctuation must not exceed +/- 10% of rated voltage. Electricity supply lines must be independent of welding transformers which can cause high supply fluctuation. Ensure that the location is convenient for wiring and piping. INSTALLATION OF INDOOR UNIT The indoor unit must be installed such that there is no short circuit of the cool discharge. Comply to the installation clearance recommended. Do not put the indoor unit where there is direct sunlight on unit. Make sure the location is suitable for piping and drainage. Precautions steps : i) Use the hanger supplied with the unit. ii) Ensure the support is strong enough to withstand the weight of the unit. 800.0 800.0 800.0 PIPINGS Do not use contaminated or damaged copper tubings. If pipings, evaporator or condenser are exposed or had been opened for 15 seconds or more, vacuum and purge with field supplied refrigerant. Generally, do not remove plastic/rubber plugs/caps from fittings, tubings and coils until ready to connect suction or liquid line into fittings. OPERATIONAL CHECK After all electrical wiring is completed and the system is charged with refrigerant, make sure unit is operating properly. Check that: a) Condenser fans are running, with warm air blowing off the condenser coil. b) Evaporator blowers are running and discharging cool air. c) Suction line inside condensing unit feels cool. d) Liquid line inside condensing unit feels warm. ELECTRICAL CONNECTION As wiring regulations differ from country to country, please refer to your LOCAL ELECTRICAL CODES for field wiring regulations and ensure that these are complied with. Besides, observe the following general precautions: a) Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work. b) Provide a power outlet to be used exclusively for each unit. A power supply disconnect and a circuit breaker for over-current protection should be provided in the exclusive line. c) The unit must be GROUNDED to prevent possible hazard due to insulation failure. d) All wiring must be firmly connected. e) Electrical wiring must not touch the refrigerant piping, compressor and any moving parts of the fan motors. 40

SPECIAL PRECAUTIONS WHEN DEALING WITH REFRIGERANT R40 7C UNIT 1) WHAT IS NEW REFRIGERANT R407C? R407C is a zeotropic refrigerant mixture which has Zero Ozone Depletion Potential (ODP = 0) and thus conformed to the Montreal Protocol regulation. It requires Polyol-ester oil (POE) oil for its compressor's lubricant. Its refrigerant capacity and performance are about the same as the refrigerant R22. 2) COMPONENTS Mixture weight composition R32(23%), R125(25%), R134a(52%) 3) CHARACTERISTIC R407C liquid and vapor components have different compositions when the fluid evaporates or condenses. Hence, when leak occurs and only vapor leaks out, the composition of the refrigerant mixture left in the system will change and subsequently affect the system performance. DO NOT add new refrigerant to leaked system. It is recommended that the system should be evacuated thoroughly before recharging with R407C. When refrigerant R407C is used, the composition will differ depending on whether it is in gaseous or liquid phase. Hence when charging R407C, ensure that only liquid is being withdrawn from the cylinder or can. This is to make certain that only original composition of R407C is being charged into the system. POE oil is used as lubricant for R407C compressor, which is different from the mineral oil used for R22 compressor. Extra precaution must be taken not to expose the R407C system too long to moist air. 4) CHECK LIST BEFORE INSTAL LATION/SERVICING Tubing Refrigerant R407C is more easily affected by dust of moisture compared with R22, make sure to temporarily cover the ends of the tubing prior to installation Compressor oil No additional charge of compressor oil is permitted. Refrigerant No other refrigerant other that R407C Tools Tools specifically for R407C only (must not be used for R22 or other refrigerant) i) Manifold gauge and charging hose ii) Gas leak detector iii) Refrigerant cylinder/charging cylinder iv) Vacuum pump c/w adapter v) Flare tools vi) Refrigerant recovery machine 5) HANDLING AND INSTALL ATION GUIDELINES Like R22 system, the handling and installation of R407C system are closely similar. All precautionary measures; such as ensuring no moisture, no dirt or chips in the system, clean brazing using nitrogen, and thorough leak check and vacuuming are equally important requirements. However, due to zeotropic nature of R407C and its hydroscopic POE oil, additional precautions must be taken to ensure optimum and trouble-free system operation. a) Filter-dryer must be installed along the liquid line for all R407C air conditioners. This is to minimise the contamination of moisture and dirt in the refrigerant system. Filter-dryer must be of molecular sieve type. For a heat-pump system, install a two-way flow filter dryer along the liquid line. b) During installation or servicing, avoid prolong exposure of the internal part of the refrigerant system to moist air. Residual POE oil in the piping and components can absorb moisture from the air. 41

c) Ensure that the compressor is not expose to open air for more than the recommended time specified by its manufacturer (typically less than 10 minutes). Removed the seal plugs only when the compressor is about to be brazed. d) The system should be thoroughly vacuumed to 1.0 Pa ( 700mmHg) or lower. This vacuuming level is more stringent than R22 system so as to ensure no incompressible gas and moisture in the system. e) When charging R407C, ensure that only liquid is being withdrawn from the cylinder or can. This is to ensure that only the original composition of R407C is being delivered into the system. The liquid composition can be different from the vapor composition. R32/R125/R134 23% / 25% / 52% 33% / 33% / 34% Composition of R407C in vapour phase is different from liquid phase. f) Normally, the R407C cylinder or can is being equipped with a dip pipe for liquid withdrawal. However, if the dip pipe is not available, invert the cylinder or can so as to withdraw liquid from the valve at the bottom. Dip-pipe Invert cylinder without dip-pipe Liquid withdrawal g) When servicing leak, the top up method, commonly practiced for R22 system, is not recommended for R407C system. Unlike R22 where the refrigerant is of a single component, the composition of R407C, which made up of three different components, may have changed during the leak. Consequently, a top up may not ensure that the R407C in the system is of original composition. This composition shift may adversely affect the system performance. It is recommended that the system should be evacuated thoroughly before recharging with R407C. 42

12. SERVICING AND MAINTENANCE Warning Disconnect from Main Supply before Servicing the air conditioner The unit is designed to give a long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. Components Maintenance Procedure Recommended Schedule Air Filters Indoor Unit Condensate Drain Pan & Pipe 1. Clean with a vacuum cleaner, or by tapping lightly and then washing in lukewarm water (below 40 C) With neutral soap. 2. Rinse well to dry before re-installing. 3. Note : Never use petrol, thinner, benzene or any other chemicals. 1. Clean away dirt or dust on grille or panel by wiping with a soft cloth soaked in lukewarm (or cold) water or neutral detergent solution. 2. Note: Never use petrol, thinner, benzene or any other volatile chemicals, which may cause plastic surface to deform. Every 2 weeks. More frequently if required. Every 2 weeks. More frequently if required. 1. Check and clean. Every 3 months. Indoor Fan 1. Check for unusual noise. As necessary. Indoor/Outdoor Coil 1. Check and remove dirt which are clogged between fins. 2. Check and remove obstacles which hinder air flow in and out of indoor/outdoor unit. Electrical 1. Check voltage, current and wiring. Compressor Compressor Lubrication Fan Motors Lubrication 2. Check faulty contacts caused by loose connections, foreign matters, etc. 1. No maintenance needed if refrigerant circuit remains sealed. However, check for refrigerant leak at joints & fittings. 1. Oil is factory charged. Not necessary to add oil if circuit remains sealed. Every month. Every month. Every 2 months. Every 2 months. Every 6 months. No maintenance required. 1. All motors pre-lubricated and sealed at factory. No maintenance required. PRE-START UP MAINTENANCE (AFTER EXTENDED SHUTDOWN) - Inspect thoroughly and clean indoor and outdoor units. - Clean or replace air filters. - Clean condensate drain line. - Clean clogged indoor and outdoor coils. - Check fan imbalance before operation. - Tighten all wiring connections and panels. - Check for refrigerant leakage. 43

The design concept of the Condensing Unit is such that all servicing can be done from the front and side of the unit. Upon removal of front and side panel, all the electrical "terminal box", fan and motor assembly and compressor are easily accessible. Under normal circumstances, these outdoor units only require a check and cleaning of air intake coil surfaces once quarterly. However, if a unit is installed in area subjected to much oil, mist and dust, the coil must be regularly cleaned by qualified Air Conditioner Service Technicians to ensure sufficient heat exchange and proper operation. Otherwise, the systems life span might be shortened. CAUTION When the compressor is to be stopped for a long time, the crankcase heater should be energized for at least 6 hours before start of operation. Do not charge OXYGEN, ACETYLENE or other flammable and poisonous gases into the refrigeration cycle when performing a leakage test or an airtight-test. These types of gases are extremely dangerous, because explosion can occur. It is recommended that nitrogen or refrigerant be charged for these types of tests. CAUTION FOR USE Bear the following points in mind to safeguard against malfunction and breakdown. Do not stick rods or other objects through the air outlet during operation since this may result to damage or injury The air conditioner must not re-start within 3 minutes after shutdown. (These models are equipped with a crankcase heater with the compressor). Make sure the air conditioner is properly grounded by checking the ground terminal. MAINTENANCE For superb performance and lasting durability, please do not forget to conduct proper and regular maintenance. Cleaning The Outdoor Unit Heat Exchanger If you use your air conditioner for prolonged period of time, the outdoor unit heat exchanger will become dirty impairing its function and reducing the performance of the air conditioned. Consult your local dealer about the cleaning of the heat exchanger. 44