MULTI-STAGE CHILLER CONTROL

Similar documents
TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

ELECTRONIC COMMUNICATING THERMOSTAT

CHR Inc. Custom Heaters & Research Digital Heating Jacket Instruction Manual

QUAD-PLATE CHILLER MODEL QPC

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

SC Installation, Operation & Application Guide

Operator: Save these instructions for future use!

Digital Pail Heater Instruction Manual

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

RCS Residential Control Systems Inc.

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

RC-2000 Thermostat Installation Instructions

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

Pump-Up Controller MODEL 4062

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

PARAGON Commercial Refrigeration Controls

Operator: Save these instructions for future use!

SC Installation, Operation & Application Guide

Pump-Down Controller MODEL 4052

HEAT HEAT HEAT COOL COOL

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Fan Coil Thermostat. Specification & Installation Instructions TFC54F3Y1. Technical Data

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

REC-8R Environmental Control. Operation and Installation Manual

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

B-40/B-41 Modulating Temperature Controller

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

T7079A,B Solid State Remote Temperature Controllers

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

OWNER S MANUAL Venstar Inc. 08/07

SC Installation, Operation & Application Guide

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

SC Installation, Operation & Application Guide

Operator: Save these instructions for future use!

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

ET10 Series Stand-alone LCD Fan Coil Thermostat

1 For All Programmable Digital Thermostat

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

T600MEP-2 Programmable Economizer Thermostat

Duct and Rough Service Carbon Monoxide Sensor

INSTALLER S & OWNER S MANUAL

OPERATING INSTRUCTIONS

MR3CCUHV Temperature/Defrost Control

YCIV Hz & Hz

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Beacon 800 Gas Monitor Operator s Manual

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Room thermostats with LCD for wall mounting

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Oxygen (O2) Single-Point Gas Detection System

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

WaterFurnace FX10 Application Guide Reversible Chiller

AH-Passport I/O (for CW systems)

Dryer Master DM510 Commissioning Guide

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Heat Pump Defrost Board Replacement Kit

Installation, Start-Up, and Operating Instructions

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

ACME ACME ENGINEERING & MANUFACTURING PB100 SPC-D INLET CONTROLLER. ACME ENGINEERING & MANUFACTURING CORP. PO BOX 978 Muskogee, OK 74402

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

AH-Elite Control (for CW systems)

Pioneer-R16 Gas Monitor Operator s Manual

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

Installation Instructions

Belt Conveyor Safety Monitoring Devices

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

Fluid Cooler Fan and Pump control panel

HAI Omni-Bus Network Installation. 5. Typical Application

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

CP CP

FPC-02 Series. Installation and Operating manual

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Transcription:

MULTI-STAGE CHILLER CONTROL Installation and Operation Manual MULTI-STAGE PUMP OFF CHILLER SENSOR A SENSOR B MODE STAGE 1 STAGE 2 STAGE 7 STAGE 8 STAGE 3 STAGE 9 STAGE 4 STAGE 10 STAGE 5 PUMP STAGE 6 ALARM CHILLER CONTROL 0603 8824809 Part No. 8825582 Effective December 6, 2006 DAIRY FARM EQUIPMENT

MULTI-STAGE CHILLER CONTROL Installation and Operation Manual TABLE OF CONTENTS Section 1.0 Introduction 1.1 General.............................................................................................................1 1.2 Technical Support..................................................................................................1 1.3 Regulatory Requirements..........................................................................................1 Section 2.0 Installation 2.1 Box Removal......................................................................................................2 2.2 Site Requirements.................................................................................................2 2.3 Electrical Requirements............................................................................................2 2.4 Mounting Instructions..............................................................................................2 Section 3.0 Electrical Wiring 3.1 Multi-Stage Temperature Control..................................................................................3 3.2 Digital Temperature Sensor Installation............................................................................3 3.3 Digital Temperature Sensor Wiring................................................................................3 3.4 Field Wiring........................................................................................................4 Figure 1: Multi-Stage Chiller Sensor/Remote Start/Flow Switch Wiring Diagram...................................4 Figure 2: Multi-Stage Chiller Relay Board...........................................................................5 Figure 3: 24-VAC Output..........................................................................................5 Figure 4: Dry Switch Closure Output..............................................................................6 3.5 Flow Switch and Remote Switch Wiring...........................................................................6 Section 4.0 Multi-Stage Chiller Control Programming 4.1 Programming Overview...........................................................................................7 4.2 Programming Parameters.........................................................................................7 4.3 Programming Parameters Table...................................................................................8 Section 5.0 Operating Instructions 5.1 General............................................................................................................9 5.2 Off/Pump/Chiller Rotary Selector Switch..........................................................................9 5.3 Operational Overview.............................................................................................9 5.4 Alarm Features...................................................................................................10 Section 6.0 Safety 6.1 General............................................................................................................1 1

TABLE OF CONTENTS Section 7.0 Disposal 7.1 General...........................................................................................................12 7.2 Chemical Disposal................................................................................................12 7.3 Solid Component Disposal........................................................................................12 Section 8.0 Manual Parameters Selection 8.1 Manual Parameters Selection Table...............................................................................13 Section 9.0 Wiring Schematics (Attached)................................................................... 15 9.1 Wiring Schematic for Falling Film Chiller and Compact Chiller, Single Phase......................................... 9.2 Wiring Schematic for Falling Film Chiller and Compact Chiller, Three Phase......................................... 9.3 Wiring Schematic for LS and LSC Chillers, Single Phase............................................................. 9.4 Wiring Schematic for LS and LSA Chillers, Three Phase.............................................................

SECTION 1.0 INTRODUCTION 1.1 General Information The Mueller multi-stage chiller control is custom designed and manufactured to provide programmable and automated staging of chiller refrigeration units. Easy to read front panel controls and two large displays allow the user to quickly and easily determine the status of the chiller equipment. Durable construction and enhanced control circuitry ensures maximum cooling and energy efficiency and superior long-term reliability.! IMPORTANT: Please read the entire manual before attempting installation of the Mueller multi-stage chiller control. 1.2 Technical Support This manual provides basic installation and operating information to ensure safe and optimum performance of the multi-stage chiller control system. Please contact your local Mueller Sales and Service Representative if you require additional technical assistance pertaining to installation or operation procedures. Manufacturer s support is available by contacting: Paul Mueller Company Dairy Farm Equipment Service Department 1600 West Phelps Street Springfield, Missouri 65802 Telephone: 1-800-756-5991 1-800-MUELLER (683-5537) Fax: 1-800-436-2466 Email: dairyfarm@paulmueller.com 1.3 Regulatory Requirements It is the responsibility of the purchaser and installer to seek the necessary regulatory pre-approval of an installation, ensuring that the site and method of installation meets all regulations for the locality. Local, state, and/or county regulations pertaining to the installation, operation, and service of the equipment may vary and must be followed accordingly. Installation and service must be performed by authorized service technicians who have the proper training and certification to install and service refrigeration and electrical equipment. Installation and Operation Manual, Part No. 8825582 1

SECTION 2.0 INSTALLATION 2.1 Box Removal 1. Remove all packaged parts. 2. Inspect all contents and report any damage to the transportation carrier. 3. Ensure all parts are present and contact Paul Mueller Company with any questions. 2.2 Site Requirements It is the responsibility of the installer and/or purchaser to provide adequate electrical service and to ensure the control is compatible with all refrigeration units and the chiller system. Please contact Paul Mueller Company prior to installation if any questions or concerns exist. 2.3 Electrical Requirements The multi-stage chiller control requires a 208V/240V/277V power supply, fused at 20 amps maximum; or a 380V/480V power supply, fused at 10 amps maximum. Install a lockable disconnect within view of the multistage chiller control between 0.6 and 1.9 meters from floor level and in accordance with CE Standard EN60947-3. See Section 9 for detailed wiring schematics. Electrical installation requirements for the refrigeration units should be obtained from the installation and operation manual specific to the refrigeration unit(s) being installed. NOTE: All wiring is to be performed in accordance with the National Electric Code and/or regulatory agency for the installation locality. All wiring that enters the multi-stage chiller control enclosure must be sealed with cord grips or liquid-tight conduit connectors. 2.4 Instructions for Mounting the Multi-Stage Chiller Control Enclosure Mount the Mueller multi-stage chiller control where it is easily accessible by the operator and protected from excessive wash down. Installation and Operation Manual, Part No. 8825582 2

SECTION 3.0 ELECTRICAL WIRING 3.1 Multi-Stage Temperature Control The Mueller multi-stage chiller control uses an electronic temperature control and one or two digital sensor(s). The following installation and calibration procedures are very important to ensure accurate sensing of the chilled water temperature.! IMPORTANT: Failure to properly follow these instructions could lead to non-warranted damage to the chiller or other system components. 3.2 Digital Temperature Sensor Installation The temperature sensors utilized by the multi-stage chiller control are extremely accurate, fast responding digital sensors also used by the Sentry III, HiPerForm II, and HiPerForm III. It is very important that the sensor(s) be installed in the provided wells in the chilled solution piping. The sensors should be adequately protected from mechanical damage and installed into the piping to ensure complete coverage at all times by the chilled solution. When sensors are installed in pipes discharging into a reservoir, Mueller recommends that the sensors be installed at the six o clock position. Care must be taken to never deform the sensor housing as damage to the enclosed circuit board could result. Mueller does not recommend the use of copper compression fittings on the digital temperature sensor.! IMPORTANT: The digital sensors must be installed into chilled solution stream for proper temperature sensing. Failure to follow these instructions could cause inaccurate temperature indication, degraded milk quality, and non-warranted damage to the chiller or other system components. 3.3 Digital Temperature Sensor Wiring If necessary, extension of the digital temperature sensor is possible by utilizing the appropriate length shielded extension wire (Part No. 8824887, sold by the foot) and three sealing splice connectors (Part No. 8825009). Do not strip the insulation from the individual connectors. Fully insert two like-colors into the splice and pinch closed with pliers. Splice green to green, red to red, black to black, and bare to bare. NOTE: Cut the aluminum foil and shield/drain wire back to the cable jacket and insulate with electrical tape inside the chiller cabinet. The foil and shield/drain wire must be insulated so that it does not make contact with any metallic surface inside the chiller cabinet. See Figure 1. Install the sensor cables together in conduit separate from all other wiring. Do not route sensor cable with other high-voltage cables or route sensor cable conduit parallel in close proximity with other high-voltage conduits. Route the sensor cables into the multi-stage chiller control enclosure. If using the shielded extension cable, cut the white wire and aluminum foil back to the cable jacket.! IMPORTANT: Do not cut off the shield/drain wires. The shield/drain wire must connect to the sensor terminal strip inside the chiller control cabinet. See Figure 1. Connect the red, black, green, and bare drain wires to the appropriate terminal connections on the logic board located on the back side of the door. Connect sensor A wires to sensor A terminals and sensor B wires to sensor B terminals. NOTE: If either of the temperature displays show? (question mark and degree symbol) you have a poor electrical connection at the sensor splice, a miss-wire of the sensor circuit, or the chilled solution is below 17 F. Installation and Operation Manual, Part No. 8825582 3

3.4 Field Wiring The Mueller multi-stage chiller control may be wired to provide 24-VAC output, dry switch closures, or any combination of the two. Please refer to the following diagrams for wiring procedures. Figure 1: Multi-Stage Chiller Sensor/Remote Start/Flow Switch Wiring Diagram PWR DATA GND GND PWR DATA GND GND SW1 COM SW2 COM RED BLK GRN SHLD RED BLK GRN SHLD SENSOR A SENSOR B REMOTE START SWITCH FLOW SWITCH N.O. IN 1 IN 2 SWITCH CABLE LOGIC BOARD SENSOR A RED BLACK GREEN SHIELD SENSOR B RED BLACK GREEN SHIELD REMOTE START SWITCH (INSTALL JUMPER IF NOT USING) N.O. FLOW SWITCH 3 NC NO 2 4 DFE00289 Installation and Operation Manual, Part No. 8825582 4

Figure 2: Multi-Stage Chiller Relay Board Figure 3: 24-VAC Output For installations requiring 24-VAC output, the 24-VAC signal is available by connecting to the bottom two terminals, terminals C and D. A B N (Constant) C D L (Switched) Installation and Operation Manual, Part No. 8825582 5

Figure 4: Dry Switch Closure Output Dry Switch Closure For installations requiring dry switch closure type output, connect to terminals A and B. NOTE: For most wiring schemes, the dry switch closure is factory wired to use 24-VAC. To use a voltage rating other than 24-VAC, remove the two wires from terminals A and B. Install the field wiring to terminals A and B of appropriate control voltage. A C B D 3.5 Flow Switch and Remote Switch Wiring The Mueller multi-stage chiller control is designed for operation with a normally open (N.O.) flow switch and a remote switch. The N.O. flow switch is an optional programmable feature (although installation is highly recommended). See Section 4.2 for flow switch programming. The flow switch should be wired between input SW2 and COM (see Figure 1 for field wiring) on the logic board (mounted to the door).! IMPORTANT: Check with your chiller manufacturer for specific flow switch requirements. Failure to follow the manufacturer s recommendations could lead to possible non-warranted damage to the equipment. The remote switch input must be made for normal chiller operation to occur (units to stage on and off). If no remote switch is to be installed, a jumper must be installed between input SW1 and COM for the control to operate (see Figure 1 for field wiring). If a remote switch is utilized, the switch must provide a dry closure for the input SW1 and COM on the logic board (mounted to the door). Installation and Operation Manual, Part No. 8825582 6

SECTION 4.0 MULTI-STAGE CHILLER CONTROL PROGRAMMING 4.1 Programming Overview The Mueller multi-stage chiller control is field programmable to allow for installation on most chiller systems utilizing one to ten independent stages. Each stage has a programmable setpoint temperature, differential, operation mode, and anti-short cycle feature; in addition, it monitors one of two system temperatures. These features allow for maximum possible flexibility. Care should be taken while selecting parameters that system operation, compressor life, and system limitations are not compromised. It is recommended that only Mueller Authorized Service Technicians adjust programming parameters.! IMPORTANT: The Mueller multi-stage chiller control ships from the factory with basic parameters. All stages are programmed OFF. It will be necessary for the technician installing the control to enter programming mode before system operation can begin. 4.2 Programming Parameters Before programming, it is recommended that you complete the programming worksheet (see Section 8.0) located at the end of the manual. Record your desired values in pencil on the worksheet and utilize this as a reference as you step through all of the parameters available. This method will save valuable time during the programming portion of the installation. To enter programming mode, press and hold the MODE button for ten seconds. Once the temperature displays change, release the button. Changes can be made to the displayed parameter. Use the MODE button to step between individual sections of the programming (i.e., Stage 1, Stage 2, Stage 3,, Alarms, etc.). Use the enter key ( ) to cycle to the individual parameters in each section. To change a parameter, press the up ( ) or down ( ) arrow keys to step through the values. Pressing and holding the up ( ) or down ( ) arrow keys will cause the values to step quickly. See 4.3, Programming Parameters Table, for a list and description of all parameters available. NOTE: Programming may be performed with the rotary switch in any position. Caution must be used during programming in the CHILLER position as to not cycle compressors on and off rapidly. Installation and Operation Manual, Part No. 8825582 7

4.3 Programming Parameters Table Parameter Parameter Code Parameter No. Section Code Description Option(s) Operational Description 1 Stages 1 10 on-off Stage Enable on or off Selects whether the particular stage should function. 2 SP Setpoint 29.0 to 99.5 F Setpoint temperature for the particular stage. ( 1.8 to 37.4 C) Cool Mode stage off temperature (opens output on fall). Heat Mode load temperature (opens output on rise) 3 DIF Differential 1.0 to 9.5 F Setpoint differential for the particular stage. Cool Mode stage on (0.4 to 5.4 C) temperature = SP+DIF. Heat Mode unload temperature = SP-DIF. 4 SEN Sensor Select A or b Selects which sensor the particular stage operates on. 5 H-C Mode Select H or C Selects whether the particular stage operates as a Cool (close on rise) or Heat (open on rise) application. Cool mode should be selected to operate compressor contactors. Heat mode should be selected to operate unloader coils. 6 ASC Anti-Short Cycle 0 to 10 Anti-short cycle restart feature for the particular stage. Indicates the length of time, in minutes, before a compressor can restart once it has been started. 7 Alarms HI High Alarm 28.0 to 99.5 F High temperature alarm setpoint. ( 2.2 to 37.4 C) 8 SEN Sensor A or b Selects which sensor will trigger a high temperature alarm. 9 LO Low Alarm 28.0 to 99.5 F Low temperature alarm setpoint. ( 2.2 to 37.4 C) 10 SEN Sensor A or b Selects which sensor will trigger a low temperature alarm. 11 Calibration A Sensor A Offset 9.5 to 9.5 F Calibration offset for temperature sensor A. ( 5.4 to 5.2 C) 12 B Sensor B Offset 9.5 to 9.5 F Calibration offset for temperature sensor B. ( 5.4 to 5.2 C) 13 Flow Flo Flow Switch y or n Selects whether a N.O. flow switch has been installed, yes or no. 14 Temperature T Degrees F/C f or c Selects Fahrenheit or Celsius temperature display. 15 Software SFT Software _ Displays installed software version. Version Examples of Heat/Cool Mode Settings Compressor #1 Stage 1 On-Off (on-off) On Setpoint (SP) 34 Off at 34 Differential (DIF) 2 On at 36 Sensor Select (SEN) A Mode Select (H-C) Cool Energizes on temperature increase. Anti-Short Cycle (ASC) 5 Min. Settings Unloader Compressor #1 Stage 2 On-Off (on-off) On Setpoint (SP) 35 35 (Loaded) Coil de-energizes. Differential (DIF) 2 33 (Unloaded) Coil energizes. Sensor Select (SEN) B Mode Select (H-C) Heat Energizes on temperature decrease. Anti-Short Cycle (ASC) 0 Min. Parameter Code: Sensor A, chilled water to PHE. Sensor B, chilled water from PHE. Installation and Operation Manual, Part No. 8825582 8

SECTION 5.0 OPERATING INSTRUCTIONS 5.1 General The multi-stage chiller control is designed for easy, touch-of-a-button operation and programming with simple visual indication of each operation mode by way of bright LED indicators. 5.2 Off/Pump/Chiller Rotary Selector Switch Select OFF when the chiller is not in operation or will not be started remotely using the remote-start feature (see Section 3.4 for remote-start wiring). The PUMP position enables the circulation pump(s), but will not allow the refrigeration unit(s) to stage on. The CHILLER mode energizes the circulation pump(s) and allows the refrigeration unit(s) to stage on and off automatically. When utilizing the remote start feature of the multi-stage chiller control, the selector switch should be placed in the CHILLER position and remain there for automatic operation via the optional remote-start switch. 5.3 Operational Overview Cool Mode Stages: The COOL mode is typically selected to operate compressor contactor coils. Stages programmed for the COOL mode operate just as a thermostat would for any cooling application. As the temperature rises past the cut-in temperature (setpoint plus differential), the output relay will close, providing either 24-VAC or a made switch closure (see Section 9 for wiring). Once the temperature falls below the cut-out temperature (setpoint), the output will reopen. Heat Mode Stages: The HEAT mode is typically selected to operate compressor unloader coils. Stages programmed for the HEAT mode operate just as a thermostat would for any heating application. As the temperature cools past the cut-in temperature (setpoint minus differential), the output relay will close, providing either 24-VAC or a made switch closure (see Section 9 for wiring). Once the temperature rises above the cut-out temperature (setpoint), the output will reopen. If we look at the operation of the unloader, the coil will be de-energized (compressor loaded) when the system temperature rises above the setpoint temperature. The coil will re-energize (compressor unloaded) when temperature falls below the setpoint temperature minus the differential. NOTE: All programmed heat stages are energized at startup to start the compressors unloaded. The compressors are then loaded according to temperature requirements. Anti-Short Cycle Feature: The Anti-Short Cycle (ASC) parameter for each stage selects the time, in minutes, which a compressor coil must wait to restart once it has been started. More simply stated, if the ASC for a particular stage is set to 5 minutes, once the stage is started (for example, at 1:00 p.m.) it cannot restart for another 5 minutes (at 1:05 p.m.). The Anti-Short Cycle parameter has no effect if a stage is programmed for HEAT mode operation. Pump Operation and Flow Switch Monitoring: The pump output is energized any time that the remote switch is made and the selector switch is in the PUMP or the CHILL position. When normal chiller operation is stopped (either by rotating the selector switch to OFF or by opening the remote switch), the pump will continue to run for an additional 20 seconds. After this time, there is an additional 4-second delay to allow loop circulation to stop before the flow switch monitoring will resume. Once this delay expires, any making of the flow switch (with the pump de-energized) will cause the alarm light on the front panel to light and the alarm output relay to close. Installation and Operation Manual, Part No. 8825582 9

5.3 Operational Overview (Continued) Pump Operation and Flow Switch Monitoring (continued): When the normal chiller operation is resumed (either by rotating the selector switch to CHILL or by closing the remote switch), the pump will restart and any required stages will begin to stage on. There is a 4-second delay from the time the pump starts until the flow switch monitoring begins. Once this delay expires, any breaking of the flow switch for longer than 1 second will cause the alarm light on the front panel to light and the alarm output relay to close as well as all COOL mode stages to open. 5.4 Alarm Features There are two separate alarm indications on the Mueller multi-stage chiller control. One is the red alarm LED on the control s front panel and the other consists of an alarm output on the relay board for remote indication. The alarm LED will light and provide an alarm output closure to indicate an alarm condition exists. Possible alarm conditions include: Temperature too high or too low, inadequate flow or flow switch malfunction, or loss of communication with one or both temperature sensors. In the event an alarm condition exists, the alarm output may be temporarily disabled to provide time to correct the condition. To utilize this function, press and release the enter key ( ). The alarm output will open and the alarm LED will begin to flash. If the alarm condition has not been corrected after 15 minutes, the alarm output will re-close and the alarm LED will once again be lit steady. Once all alarm conditions are corrected, alarm indications will clear and the operation will resume as before. The specific conditions necessary to cause an alarm are as follows: Temperature: Any time the temperature of sensor A or B is below the programmed low temperature alarm setpoint or above the programmed high temperature alarm setpoint, an alarm condition exists. Operation continues as before during a high temperature alarm condition with the alarm LED lit and the alarm output closed. In the case of a low temperature alarm, the control will immediately unload all stages and de-energize all compressor contactors in order to protect the heat transfer surfaces from damage. Also, any loss of communication with one or both temperature sensors will cause an alarm condition to exist. This is indicated by a? symbol in the appropriate sensor display. Flow Switch (with Flo programmed for Yes ): Any time the circulation pump is energized and the flow switch is open, an alarm condition exists. This alarm is displayed in the SENSOR A window as Flo. Conversely, anytime the circulation pump is de-energized and the flow switch is closed, an alarm condition exists. NOTE: There is a 4-second delay when the pump is energized or de-energized before flow switch monitoring is active to allow the flow of chilled solution to close the switch or open the switch. Installation and Operation Manual, Part No. 8825582 10

SECTION 6.0 SAFETY SAFETY/ALERT: See all Safety, Warning, and Caution labels displayed in Section 6.0. 6.1 General The Mueller multi-stage chiller control system should be operated by qualified personnel who are familiar with the equipment and all instructions. Improper handling, operation, or service of the equipment, electricity, or any chemicals can create a health hazard and possible non-warranted damage to the equipment. An authorized Mueller Service Representative who is trained and certified in electrical and refrigeration work must perform all service. This equipment can start automatically! Use extreme caution when servicing. All guards and covers must be in place during operation to prevent mechanical and electrical hazards. Installation and Operation Manual, Part No. 8825582 11

SECTION 7.0 DISPOSAL 7.1 General If the control is removed from the installation site, ensure the materials and any refrigerants and/or chemicals are disposed of according to applicable codes and regulations. 7.2 Chemical Disposal All refrigerants and oils can be harmful and toxic to the environment if not properly disposed of. Consult each chemical label and comply with all local environmental regulations and agencies. 7.3 Solid Component Disposal The controls basic components consist of steel, copper, rubber, and plastics which may be separated and recycled. Installation and Operation Manual, Part No. 8825582 12

SECTION 8.0 MANUAL PARAMETERS SELECTION 8.1 Manual Parameters Selection Sheet Parameter Parameter Parameter No. Section Code Code Description Option(s) Selection 1 Stage 1 on - off Stage Enable on or off 2 SP Setpoint 29.0 to 99.5 F ( 1.8 to 37.4 C) 3 DIF Differential 1.0 to 9.5 F (0.4 to 5.4 C) 4 SEN Sensor Select A or b 5 H-C Mode Select H or C 6 ASC Anti-Short Cycle 0 to 10 1 Stage 2 on - off Stage Enable on or off 2 SP Setpoint 29.0 to 99.5 F ( 1.8 to 37.4 C) 3 DIF Differential 1.0 to 9.5 F (0.4 to 5.4 C) 4 SEN Sensor Select A or b 5 H-C Mode Select H or C 6 ASC Anti-Short Cycle 0 to 10 1 Stage 3 on - off Stage Enable on or off 2 SP Setpoint 29.0 to 99.5 F ( 1.8 to 37.4 C) 3 DIF Differential 1.0 to 9.5 F (0.4 to 5.4 C) 4 SEN Sensor Select A or b 5 H-C Mode Select H or C 6 ASC Anti-Short Cycle 0 to 10 1 Stage 4 on - off Stage Enable on or off 2 SP Setpoint 29.0 to 99.5 F ( 1.8 to 37.4 C) 3 DIF Differential 1.0 to 9.5 F (0.4 to 5.4 C) 4 SEN Sensor Select A or b 5 H-C Mode Select H or C 6 ASC Anti-Short Cycle 0 to 10 1 Stage 5 on - off Stage Enable on or off 2 SP Setpoint 29.0 to 99.5 F ( 1.8 to 37.4 C) 3 DIF Differential 1.0 to 9.5 F (0.4 to 5.4 C) 4 SEN Sensor Select A or b 5 H-C Mode Select H or C 6 ASC Anti-Short Cycle 0 to 10 1 Stage 6 on - off Stage Enable on or off 2 SP Setpoint 29.0 to 99.5 F ( 1.8 to 37.4 C) 3 DIF Differential 1.0 to 9.5 F (0.4 to 5.4 C) 4 SEN Sensor Select A or b 5 H-C Mode Select H or C 6 ASC Anti-Short Cycle 0 to 10 Installation and Operation Manual, Part No. 8825582 13

8.1 Manual Parameters Selection Sheet (Continued) Parameter Parameter Parameter No. Section Code Code Description Option(s) Selection 1 Stage 7 on - off Stage Enable on or off 2 SP Setpoint 29.0 to 99.5 F ( 1.8 to 37.4 C) 3 DIF Differential 1.0 to 9.5 F (0.4 to 5.4 C) 4 SEN Sensor Select A or b 5 H-C Mode Select H or C 6 ASC Anti-Short Cycle 0 to 10 1 Stage 8 on - off Stage Enable on or off 2 SP Setpoint 29.0 to 99.5 F ( 1.8 to 37.4 C) 3 DIF Differential 1.0 to 9.5 F (0.4 to 5.4 C) 4 SEN Sensor Select A or b 5 H-C Mode Select H or C 6 ASC Anti-Short Cycle 0 to 10 1 Stage 9 on - off Stage Enable on or off 2 SP Setpoint 29.0 to 99.5 F ( 1.8 to 37.4 C) 3 DIF Differential 1.0 to 9.5 F (0.4 to 5.4 C) 4 SEN Sensor Select A or b 5 H-C Mode Select H or C 6 ASC Anti-Short Cycle 0 to 10 1 Stage 10 on - off Stage Enable on or off 2 SP Setpoint 29.0 to 99.5 F ( 1.8 to 37.4 C) 3 DIF Differential 1.0 to 9.5 F (0.4 to 5.4 C) 4 SEN Sensor Select A or b 5 H-C Mode Select H or C 6 ASC Anti-Short Cycle 0 to 10 7 Alarms HI High Alarm 28.0 to 99.5 F ( 1.8 to 37.4 C) 8 SEN Sensor A or b 9 LO Low Alarm 28.0 to 99.5 F ( 2.2 to 37.4 C) 10 SEN Sensor A or b 11 Calibration A Sensor A Offset 9.5 to 9.5 F ( 5.4 to 5.2 C) 12 B Sensor B Offset 9.5 to 9.5 F ( 5.4 to 5.2 C) 13 Flow Flo Flow switch y or n 14 Temperature T Degrees F/C f or c 15 Software SFT Software _ * *Displays installed software version. Installation and Operation Manual, Part No. 8825582 14

SECTION 9.0 WIRING SCHEMATICS (ATTACHED) Installation and Operation Manual, Part No. 8825582 15

9.1 Wiring Schematic for Falling Film Chiller and Compact Chiller, Single Phase LOGIC BOARD RELAY BOARD Installation and Operation Manual, Part No. 8825582

9.2 Wiring Schematic for Falling Film Chiller and Compact Chiller, Three Phase LOGIC BOARD RELAY BOARD Installation and Operation Manual, Part No. 8825582

9.3 Wiring Schematic for LS and LSC Chillers, Single Phase Installation and Operation Manual, Part No. 8825582

9.4 Wiring Schematic for LS and LSA Chillers, Three Phase LOGIC BOARD RELAY BOARD Installation and Operation Manual, Part No. 8825582

1600 West Phelps Street Springfield, Missouri 65802, U.S.A. 417-575-9000 1-800-MUELLER DFE Service: 1-800-756-5991 Fax: 417-575-9887 1-800-436-2466 dairyfarm@paulmueller.com Visit dfe.paulmueller.com to see all of our COOL products! 2006 2016 Paul Mueller Company (2/16) 8825582