compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Similar documents
3M Oldham OLCT 100. Description. Fixed Gas Detector

OLC(T) 100 FIXED GAS DETECTOR

GAS DETECTOR ST400EC PART.NO

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Sieger Apex. Flexibility that meets your requirements

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

ALTAIR 5X Multigas Detector Product Specification

DEGA NBx-yL III INSTRUCTION MANUAL. Gas Detection Transmitter

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Monitores Personales. Personal Monitor

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

MICRO III (G202 / G202s / G212) Single Gas Detector

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Model D12. Digital Gas Transmitter

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Micro III (Models G203, G203S, and G213) Operation Manual

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

ESD500. ESD500 Combustible / Toxic Gas Detector

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Toxic Gas Detection. Model F12. Toxic Gas Detection

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

ESD3000 ESD200 Combustible / Toxic Gas Detector

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

SP-220. Features. Combustible handheld gas leakage detector

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Frequently Asked Questions

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Stand Alone DYNAGARD SP Operation Manual

Transmitters/Sensors. OLCT Series

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Fixed Gas & Flame Detection International Product Range Overview

APPLICATION DATA SHEET

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

ALTAIR 5X Multigas Detector

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

KAE Gas Alarm Operation Manual

MICRO IV. Operation Manual. Single Gas Detector

Warranty Registration

Dräger X-am 7000 Multi-Gas Detection

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

MSA Portable Gas Detection

testo 316-EX gas leak detector Instruction manual

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

incontrol Systems Inc. Flame and Gas Detection

GMA 36 Pro. Operation Manual. Stand Alone Monitor

Explosion protection Marijan Gorše, dipl. ing.

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Two-Channel Gas Controller

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Micro IV Operation Manual

Gas Detection For Life

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

The Art of Gas Detection

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

ALTAIR 5X Multigas Detector

portable gas analyser

GS100M Gas Detection Controller

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

GMA 36 Pro. Operation Manual. Stand Alone Monitor

Safe Operation Manual. Honeywell IQ Force Gas Detector

Model D12-IR. Digital Gas Transmitter...

1.1 Definitions of alert icons. For your safety

MSA XCell Sensors. Because every life has a purpose

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

IGD.CO.UK

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER

Industrial Grade Gas Detection Detecting The Difference

DETCON MODEL SERIES 700 GAS DETECTORS

Model Series 700. detcon. Environmentally Bulletproof Gas Detection Sensors. Multi-Layer Surge Protection Water-Proof Corrosion-Proof

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Transcription:

iso 9001:2008 Quality Management Systems Systéme de Qualité www.sgs.com possibility of additional functions detection of critical temperature detection of flooding electrochemical sensor catalytic sensor infrared sensor semicoductor sensor Detection of more than 200 flammable and toxic gases DEGA 05L-2-AC-x-yL compact detector Products in accordance with Regulation n.361/2007 Coll. Regulation n.312/2005 Coll. n.268/2011 Decree no., and standards: CSN EN 50402 (2011) and CSN 73 6058 (2009)

Compact detector A digital compact gas detector with a built-in sensor selected in accordance with the type of gas, including evaluation, with an LCD display showing the values measured, with an acoustic alarm and a reset button for the acoustic alarm on the control panel, provided with the function of monitoring the calibration dates and with auto-control, with the option for connecting an additional transmitter, an internal temperature sensor, an external flood sensor and a circuit for controlling the valve using a current pulse. Recommended accessories: DEGA NBx-yl II - external additional transmitter DEGA Zc II - external flood sensor DEGA05L-Tc - internal critical temperature sensor DEGA05L-V - a circuit for controlling emergency valves DEGA05L-12VDC - Special circuit for 12V DC DEGA05L-24VDC - Special circuit for 24V DC The transmitter is not intended for detection and sensing in industrial or commercial premises that require the ATEX certification nor for Ex environments. For these areas, we recommend transmitters of the DEGA NSx-yL types. The DEGA 05L-2-AC-x-yL detector is available with the following sensors: (whereby x= the symbol for a specific gas, y= the symbol for the type of sensor) DEGA05-2-AC-x-EL with an electrochemical sensor This operates on the principle of measurement of the change in the electrical parameters of electrodes placed in electrolyte, due to the redox reaction of detected gas on their surface. These sensors have a favourable selectivity and the capacity to detect very low concentrations of gases. In the DEGA systems they are utilised primarily for the detection of toxic gases. DEGA05-2-AC-x-CL with a catalytic sensor (Pelistor) These work on the principle of catalytic combustion the gas concentration is measured in accordance with the amount of heat released during a controlled combustion reaction. The reaction is prompted by a suitable temperature and the presence of a catalyst. These sensors can be used for the detection of a wide range of combustible gases. The sensors are characterised by their fast response, long life and high degree of stability. For their proper functioning they require at least 10% of the oxygen in the air. In an environment containing corrosive substances (alkaline and/or acidic compounds, silicon, sulphur, lead, etc.) the degradation of the sensor is accelerated. DEGA05-2-AC-x-IL with an infrared sensor (IR) The highest-quality detecting method, which works on the principle of infrared spectroscopy. These sensors excel in the high level of their selectivity and their resistance in environments containing corrosive substances and, under ideal conditions, their theoretically unlimited operating life. DEGA05-2-AC-x-SL with a semiconductor sensor The least expensive method of sensing. They work on the principle of the measurement of the change in the electrical conductivity of semiconductors that occurs in the event of a change in the concentration of the gas detected. Its advantages are its long operating life when it is used in a clean environment and also the wide range of models available for different types of gases and vapours. Its disadvantages are its low degree of selectivity (a lesser ability to distinguish between the different types of gases in the mixture) and in environments containing corrosive substances (alkaline and acidic compounds, silicones, sulphur compounds, etc.) an accelerated degradation of the sensor takes place. Basic types Identification system of the transmitter: Gas transmitter DEGA05L-2-AC-x yl The product type (DEGA 05L) 2-level detection Power supply 230 V AC The type of gas detected A type of sensor with a linear output 2

DEGA05L-2-AC-x-CL (catalytic sensor) The type of sensor Detected gas Measuring range Standard alarm setting on the controller DEGA05-2-AC-M-CL DEGA05-2-AC-P-CL Methane (CH4) / Natural Gas (CH4) / CNG (CH4) / Biogas (CH4) Butane (C4H10) / LPG (C4H10) / Propane-butane (C4H10) 0 100% LEL level 1: 10% LEL, level 2: 20% LEL 0 100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-H-CL Hydrogen (H2) 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-A-CL Amonia (NH3) 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-B-CL Gasoline 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-L-CL Other flammable and explosive gases and vapours, in accordance with the selectivity of the sensor 0-100% LEL level 1: 10% LEL, level 2: 20% LEL Note: LEL - Lower Explosion Limit Alarm settings on the controller can be freely selected (within the measuring range) in accordance with the customer s requirements DEGA05L-2-AC-x-CL (semiconductor sensor) The type of sensor Detected gas Measuring range Standard alarm setting on the controller DEGA05-2-AC-C-SL Carbon monoxide (CO) 0-10.000 ppm level 1: 80 ppm, level 2: 130 ppm DEGA05-2-AC-M-SL DEGA05-2-AC-P-SL Methane (CH4) / Natural Gas (CH4) / CNG (CH4) / Biogas (CH4) Butane (C4H10) / LPG (C4H10) / Propane-butane (C4H10) 0 100% LEL level 1: 10% LEL, level 2: 20% LEL 0 100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-A-SL Amonia (NH3) 0-1.000 ppm (accuracy +/- 50ppm) level 1: 300ppm, level 2: 400 ppm DEGA05-2-AC-B-SL Gasoline 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-F-SL Freon 100 600 ppm level 1: 300ppm, level 2: 600ppm DEGA05-2-AC-R-SL Refrigerants: R401A, R404A, R407C, R32, R410A, R12, R22 0 20.000 ppm In accordance with the type of refrigerant DEGA05-2-AC-HFO-SL Refrigerant: HFO-1234yf; R1234yf; 2,3,3,3-Tetrafluoropropylene 0 20.000 ppm level 1: 10 ppm, level 2: 20 ppm DEGA05-2-AC-H-SL Hydrogen (H2) 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-Y-SL Acetylene (C2H2) 0-100% LEL level 1: 10% LEL, level 2: 20% LEL DEGA05-2-AC-L-SL Other flammable and explosive gases and vapours, in accordance with the selectivity of the sensor 0-100% LEL (0 1% vol.) level 1: 10% LEL, level 2: 20% LEL Note: LEL - Lower Explosion Limit Alarm settings on the controller can be freely selected (within the measuring range) in accordance with the customer s requirements 3

DEGA05L-2-AC-x-EL (electrochemical sensor) The type of sensor Detected gas Measuring range Standard alarm setting on the controller DEGA05-2-AC-C-EL Carbon monoxide (CO) 0-300 ppm (0-1.000ppm) level 1: 45 ppm, level 2: 130 ppm, ALARM PEL : in accordance with CSN 50 291: 120mi n./30ppm Application: Detection in residential buildings If required the PEL ALARM can also be set: a) in accordance with CSN 73 6058: 30min/87 ppm Application: Underground Garages b) in accordance with Government Regulation No. 321/2007: 8 hours/26 ppm Application: The working environment of employees DEGA05-2-AC-A-EL Amonia (NH3) 0-50ppm (0-1000ppm) level 1: 18 ppm, level 2: 47 ppm Regulation No. 321/2007: 8hod./ 20 ppm DEGA05-2-AC-CL-EL Chlorine (Cl2) 0-20 ppm DEGA05-2-AC-O-EL Oxygen (O2) 0-25% vol. level 1: 1 ppm, level 2: 3 ppm Regulation No. 321/2007: 8hod./0,2 ppm NPK-P: 0,516 ppm level 1: 18% vol., level 2:15% vol. If required the PEL ALARM can also be set: 1 st. 23% vol., level 2:25% vol. DEGA05-2-AC-O3-EL Ozone (O3) 0-5 ppm (0-100 ppm) level 1: 0,1 ppm, level 2: 0,3 ppm Regulation No. 321/2007: 8hod./0,05 ppm NPK-P: 01018 ppm DEGA05-2-AC-HCL-EL Hydrogen chloride (HCl) 0-20 ppm level 1: 7 ppm, level 2: 9,3 ppm Regulation No. 321/2007: 8hod./5,43 ppm DEGA05-2-AC-H2S-EL Hydrogen sulfide (H2S) 0-50 ppm (0-200ppm) (0-2000ppm) level 1: 10 ppm, level 2: 13 ppm Regulation No. 321/2007: 8hod./7,1 ppm DEGA05-2-AC-NO2-EL Nitrogen dioxide (NO2) 0-20 ppm (0-1 00 ppm) level 1: 8 ppm, level 2: 10 ppm Regulation No. 321/2007: 8hod./4,94 ppm DEGA05-2-AC-NO-EL Nitric oxide (NO) 0-250 ppm (0-1 000 ppm) level 1: 7 ppm, level 2: 10 ppm Regulation No. 321/2007:8hod./7,57 ppm DEGA05-2-AC-SO2-EL Sulfur dioxide (SO2) 0-20 ppm level 1: 2,5 ppm, level 2: 3,5 ppm Regulation No. 321/2007: 8hod./1,91 ppm DEGA05-2-AC-CH2O-EL DEGA05-2-AC-C2H4-EL DEGA05-2-AC-C2H4O-EL DEGA05-2-AC-H-EL DEGA05-2-AC-HCN-EL DEGA05-2-AC-PH3-EL Formaldehyde (CH2O) Ethene (Ethylene) (C2H4) Ethylenoxide (oxirane) (C2H4O) Acetaldehyd, Vinyl alcohol (ethenol) Hydrogen (H2) Hydrogen cyanide (HCN) Fosfan/Fosfin (PH3) 0-10 ppm (0-2000 ppm) 0-10 ppm (0-1 500 ppm) level 1: 0,3 ppm, level 2: 0,7 ppm level 1: 7 ppm, level 2: 10 ppm 0 10 ppm level 1: 0,8 ppm, level 2: 1,5 ppm 0-1000 ppm (0-4000ppm) 0-50ppm (0-100ppm) 0-5 ppm (0-20 ppm) level 1: 200 ppm, level 2: 400 ppm level 1: 5 ppm, level 2: 8,3 ppm 1. st. 0,1 ppm, 2. st. 0,2 ppm 4

The type of sensor Detected gas Measuring range Standard alarm setting on the controller DEGA05-2-AC-SIH4-EL Silane (SiH4) 0-50 ppm level 1: 3 ppm, level 2: 5 ppm DEGA05-2-AC-CLO2-EL Chlorine dioxide (ClO2) 0-1 ppm (0-50ppm) level 1: 0,1 ppm, level 2: 0,2 ppm DEGA05-2-AC-BR2-EL Bromine (Br2) 0-20ppm level 1: 0,1 ppm, level 2: 0,2 ppm DEGA05-2-AC-HBR-EL Hydrobromic acid (HBr) 0-20ppm level 1: 8 ppm, level 2: 9,3 ppm DEGA05-2-AC-L-EL Other chemical substances, in accordance with the customer s requirements In accordance with the type of sensor In accordance with the chemical substance Note: LEL - Lower Explosion Limit Alarm settings on the controller can be freely selected (within the measuring range) in accordance with the customer s requirements DEGA05L-2-AC-x-IL (infrared sensor) The type of sensor Detected gas Measuring range Standard alarm setting on the controller DEGA05-2-AC-CO2-IL DEGA05-2-AC-M-IL DEGA05-2-AC-PB-IL DEGA05-2-AC-PP-IL DEGA05-2-AC-B-IL Carbon Dioxide (CO2) /Biogas (CO2) Methane (CH4) / Natural Gas (CH4) / CNG (CH4) / Biogas (CH4) Butane (C4H10) / LPG (C4H10) / Propane-butane (C4H10) Propane (C3H8) Gasoline 0-5 % vol. (0-100 % vol.) 0 100% LEL 0 100% LEL 0 100% LEL 0-100% LEL level 1: 1,0%, level 2: 2,5% DEGA05-2-AC-N2O-IL Nitrous oxide (N2O) 0 1% vol. level 1: 0,5% vol., level 2:1% vol. DEGA05-2-AC-L-IL Other flammable and explosive gases and vapours, in accordance with the selectivity of the sensor 0-100% LEL Note: PEL ALARM: Permissible Exposure Limit (PEL) of the chemical substance, i.e. the maximum permissible value of the time-weighted average (TWA) of the concentration of the gas in air LEL - Lower Explosion Limit 5

Supply Voltage DEGA05L: Cable for the power supply of DEGA05: Cable for the connection Flood sensor DEGA Zc II Cable for the connection additional transmitter DEGA NBx-yL II: Note: In case of connecting sensors with detector DEGA05L at greater distances, please contact the manufacturer. Input: Output: Relay contact ampacity: Technical data and information Ingress protection: IP 43 Working environment: Degree of accuracy: 2,5 Response time (T90): DEGA05-2-AC-x-EL DEGA05-2-AC-x-CL DEGA05-2-AC-x-IL DEGA05-2-AC-x-SL Warm-up time: DEGA05-2-AC-x-EL DEGA05-2-AC-x-CL DEGA05-2-AC-x-IL DEGA05-2-AC-x-SL Stabilisation period: DEGA05-2-AC-x-EL DEGA05-2-AC-x-CL DEGA05-2-AC-x-IL DEGA05-2-AC-x-SL Dimensions (W x H x D): Weight: Type os sensor Expected operational life of the sensor in a clean environment 230 V AC/50Hz cable 3 x 1,5 mm2 cable 4 x 1 mm2 (max.100m) or UTP cat. 5e shielded cable 3 x 1 mm2 (max. 600 m) shielded cable 3 x 1,5 mm2 (max. 1 100 m) 7W 5x relay- a potential-free switching contact resistance load: 8 A / 250 V/50Hz 8 A / 30 VDC inductive load: 1,6 A / 30 VDC BE1 on-explosive atmosphere BNV (CSN EN 60079 10) max. 180 seconds (in accordance with the type of sensor) max. 20 seconds max. 15 seconds max. 30 seconds max. 1 min. max. 3 min. 10 sekund max. 3 min. Operating temperature range: -20 to + 60 C Relative humidity of the ambient air: max. 1 hod. (5 dnů bez napájení) max. 6 hod. (5 dnů bez napájení) max. 5 minut (5 dnů bez napájení) max. 6 hod. (5 dnů bez napájení) 225 x125 x57 mm 0,6 kg catalytic, electrochemical, infrared, semiconductor catalytic (3-6 years) electrochemical (1-3 years) infrared (at least 5 years or more) semiconductor (3-6 years) max. 95% with air pressure 86-108 kpa. 6

Accessories DEGA Zc II External flood sensor DEGA NBx-yL II adittional gas transmitter 7

Manufacturer: DEGA CZ s.r.o., K Žižkovu 640/9, 190 00 Prague 9, Czech Republic TAX ID: CZ 279 029 43; Company ID: 279 02 943; Phone (cz): +420 774 447 661-2, Fax: +420 227 203 512 E-mail: info@dega.cz, Website: www.dega.cz 2012 DEGA CZ S.R.O.