CIRCUIT BREAKER - GAS

Similar documents
Installation Instructions

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

IEEE Transformer Committee PC Distribution Transformer Monitoring - User

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7

TRANS ATLANTIC TRADING ENTERPRISE INC.

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

www. ElectricalPartManuals. com INSTRUCTIONS DRY TYPE TRANSFORMERS OPERATION AND MAINTENANCE OF

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School

Cook - Wissahickon Elementary School

THRU-THE-WALL AIR CONDITIONERS

SECTION STEAM CONDENSATE PUMPS

Installation Instructions

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

WHISPA III 5000 WM & 9000 WM. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual. Part Number: Issue 1

Electric Coils. Blower Coils. Product Information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Installation Instructions

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

Inventory List for Abilene Location

C. Samples for Initial Selection: For units with factory-applied color finishes.

Property risk solutions

ANNEX A-1 GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BOILER BALANCE OF PLANT STEAM TURBINE GENERATOR MISCELLANEOUS - GEOTHERMAL EXTERNAL

State College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT

Installation Instructions

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

L A signature series TA T N E RE O, A L L A T S IN

GUIDE SPECIFICATIONS AQUARIUS ii

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

Appendix B9 Geothermal Unit Cause Codes

SECTION DOMESTIC WATER HEATERS

SERVICING S-15 CHECKING CAPACITOR

Glossary. Carbon Dioxide (CO 2

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

GARCIA GALUSKA DESOUSA Consulting Engineers

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

ASME Packaged Electric Water Heater

TM Series. Induced Draft, Counter Flow Optional Accessories

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

Control and power circuit fusing to meet N.E.C.

National Electrical Code

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Comfort Survey Aquila Investment Gr A oup. quila Investment Group.

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

MODELS B1PA024, 030 AND 036

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

Installation Instructions

How to reduce exposure to arc flash hazards

Exhibit A. Mechnical, Plumbing, and Electrical Plan Check and Inspection Fees. Total Cost Per Unit FEE TYPES MECHANICAL PERMIT FEES

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Requirements for Electrical Installations

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Installation Instructions

FACILITY CONNECTION STANDARD

Smart Grid Tables. Exploring the Electrical Infrastructure Grades 9-12

30GN FLOTRONIC II AIR-COOLED CHILLERS

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

MARVAIR SCHOLAR III HEAT PUMPS & AIR CONDITIONERS MODELS VAIA & VAISA EXPLODED VIEW PARTS ID

Construction Electrical

SECTION EXTERIOR LIGHTING

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

48PGD/E/F/L/M/N PG20-28

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

DOCUMENT TABLE OF CONTENTS

DANFOSS OPTYMA PLUS INVERTER UNITS

ULTRA-SAFE Explosion-proof Duct Heaters

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Jr. Tech (JT-1, 2, 3) Knowledge Areas

50TM TFF COMBINATION HEATING/COOLING UNITS

UEE30811 Q-Tracker Work Tasks

2 X 1996 Wartsila 18V mw Each 50hz HFO Generator Sets

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Paragon. Induced Draft, Counter Flow Optional Accessories

30GT FLOTRONIC AIR-COOLED CHILLERS

Electrical Inspection Service & Distribution

50TM COMBINATION HEATING/COOLING UNITS

Company Directive STANDARD TECHNIQUE : SP1N

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

UNIFIED FACILITIES GUIDE SPECIFICATIONS

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

ELECTRICAL POWER SYSTEMS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Monitoring of Electrical Equipment Failure Indicators and Alarming

GUIDE SPECIFICATIONS AQUARIUS ii

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

CxA to Answer this Section

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Drexan Energy Systems Inc.

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing

Transcription:

CIRCUIT BREAKER - GAS Capabilities: In a large substation, circuit breakers are used to interrupt any short-circuits or overload currents that may occur on the network. A 345 kv, high voltage, three position/phase gas circuit breaker. Description:. Circuit Breaker Gas A 345 KV Three Position Serial Numbers: N/A, N/A, 214, 215, 213, 207, 216, 212, 204, 205, N/A, N/A, 201, 0283A7944-201, 0283A7944-202 In Service: 5/31/1983 thru 8/31/1988 Quantity: 15 units Weight: 51,000 lbs Original Cost: 13 were $281,830.05 and 2 were $349,818.70 Condition: They appear to be in fair condition. Should be inspected for functionality. Location: X-533A Switch Yard 1

TRANSFORMER POWER McGraw-Edison Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 330/13.8 KV 100,000 Serial Numbers: 26201-2, 26201-1 In Service: 1 in 2/28/1955. 1 in 1/31/1975. Quantity: 2 units Size: Untanking Height 22 5 Weight: Serial #26201-2 #26201-1 To be lifted untanking: 244900 253500 lbs Tank and Fittings: 99600 89100 lbs Type 442 LTC Mechanism: 1600 1600 lbs Oil 15865 Main & Selector Comp:119000 Oil 15825 118700 lbs Oil 700 Contactor Compartment: 5200 Oil 700 5200 lbs Total: 470,000 468,100 lbs Original Cost: $758,897.97 and $658,305.55 Condition: All but one transformer exceeds life cycle. Location: X-533A Switch Yard. 2

TRANSFORMER POWER Large Westinghouse Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 330/13.8 KV 100 000 Serial Numbers: 6530371, 5069361, 6530372, 5069360 In Service: 2/28/1955. There are tags to indicate an upgrade in 1976. Quantity: 4 units. Weight: Core and coils 275,000 lbs Case 128,000 lbs Oil 195,000 lbs Total 598,000 lbs Original Cost: $807,358.00 Condition: All transformers do not exceed life cycle. Location: X-533A Switch Yard. 3

TRANSFORMER POWER - Westinghouse Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 330/14.4 KV 125 MVA Serial Numbers: 7002476, 7002477, 7002449, 7002358, 7002363, 7002418, 7002419 In Service: 6/30/1979 Quantity: 7 units. Weight: Core and coils 202,000 lbs Case 50,000 lbs Oil 75,200 lbs Total 327,200 lbs Shipping 232,970 lbs Original Cost: Varied from $701,226.01 to $730,102.20 Condition: All transformers do not exceed life cycle. Location: X-533A Switch Yard. 4

TRANSFORMER POWER - GE Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 330/13.8 KV 100,000 Serial Numbers: C155609, C155607 In Service: 2/28/1958 Quantity: 2 units Weight: When untanking 146,500 lbs Tank & Fitting 108,500 lbs Main tank No. 10-C 7810 132,700 lbs Top selector No. 10-C 790 5,900 lbs Contactor No. 10-C 520 3,900 lbs Total 397,500 lbs Original Cost: $757,197.36 and $706,142.57 Condition: According to identified markings all transformers exceed life cycle. Location: X-533A Switch Yard. 5

TRANSFORMER POWER Allis-Chalmer Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 330/13.8 KV 100,000 Serial Numbers: 1-0140-24891-2, 1-0140-24891-5 In Service: The one located in the switchyard 12/31/1954. Quantity: 2 units. Size: Height 460 inches Weight: Core and coil 296,700 lbs Oil 20888 157,000 lbs Tank & Fitting 105,300 lbs Total 559,000 lbs Original Cost: $963,480.01 for one in Switch Yard. Condition: According to identified markings all transformers exceed life cycle. Location: One transformer is in X-533A Switch Yard and one transformer is on a concrete pad behind the X-533A Switch Yard. 6

TRANSFORMER POWER BBC Capabilities: It is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power HV 13.8 KV/LV 2.4 KV Serial Number: SB77582-0101 In Service: Unknown Life Cycle: Unknown Quantity: 1 unit. Weight: Core and coils 2,934 lbs Oil 20888 1,582 lbs Tank & Fitting 1,087 lbs Total 5,603 lbs Original Cost: Unknown Condition: Unknown Location: It is setting disconnected on a concrete pad behind X-533A Switch Yard. 7

TRANSFORMER POWER PowerZone Capabilities: It is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power KVA 1500/1932 13800 Volts Serial Number: 820749-2 In Service: Unknown. Life Cycle: Unknown. Quantity: 1 unit. Size: Untanking height of 150 inches. Weight: Core and coil 4,055 lbs Oil 20888 4,342 lbs Tank & Fitting 3,743 lbs Total 12,140 lbs Original Cost: Unknown. Condition: Unknown. Location: It is setting disconnected on a concrete pad behind X-533A Switch Yard. 8

TRANSFORMER POWER Fayetteville Capabilities: It is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power KVA 6000 OA / 7500 FA 13800 Delta Volts Serial Number: 95156-01 In Service: Unknown. Life Cycle: Unknown. Quantity: 1 unit. Size: Untanking height of 150 inches. Weight: Core and coil 14,000 lbs Tank & Fitting 9,595 lbs Oil 960 gallons 7,105 lbs Total 30,700 lbs Original Cost: Unknown. Condition: Unknown. Location: It is setting disconnected on a concrete pad behind X-533A Switch Yard. 9

TRANSFORMER POWER GE Capabilities: It is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power KVA 6000 OA / 7500 FA 13800 Delta Volts Serial Number: B686511 In Service: Unknown. Life Cycle: Unknown. Quantity: 1 unit. Weight: Untanking 191,000 lbs Tank & Fitting 108,500 lbs Oil 1700 gallons Main 127,000 lbs Oil 790 Gallons 5,900 lbs Oil 520 gallons Contactor 3,900 lbs Total 436,500 lbs Original Cost: Unknown. Condition: Unknown. Location: It is setting disconnected on a concrete pad behind X-533A Switch Yard. 10

TRANSFORMER POWER Square D Company Capabilities: It is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power Serial Number: 796006843 In Service: Unknown. Life Cycle: Unknown. Quantity: 1 unit.. Weight: Core and coil 2,540 lbs Tank & Fitting 2,765 lbs Oil 280 gallons 2,100 lbs Untanking 2,540 lbs Total 7,405 lbs Original Cost: Unknown. Condition: Unknown. Location: It is setting disconnected on a concrete pad behind X-533A Switch Yard. 11

TRANSFORMER GROUNDING GE Zig Zag Capabilities: Grounding transformers are used in utility distribution networks and in some power electronic converters in order to provide a neutral point in a three-wire system. Description: Transformer Grounding Zig Zag GE OA-JT. Serial Numbers: H-885175A, H-885175B In Service: 6/30/1979 Quantity: 2 units. Weight: Untanking 3,800 lbs Tank & Fitting 1,850 lbs 10C Oil 425 Gallon 3,150 lbs Total 8,800 lbs Original Cost: $24,520.79 Condition: They appears to be in fair condition with over 9 years of life cycle remaining. Location: X-533A Switch Yard. 12

TRANSFORMER GROUNDING GE Capabilities: A grounding transformer is used to provide a ground path to either an ungrounded "Y" or a delta connected system. Description: Transformer Grounding Zig Zag GE OA-J. Serial Numbers: C155653, C155654, C155655, C155651, C155656, C155649, C155648, C155643, C155647, C155645, C155646, C155642, C155644, C155650 In Service: 2/28/1955 Quantity: 15 units. Weight: Untanking 5,875 lbs Tank & Fitting 1,850 lbs 10C Oil 400 Gallon 3,000 lbs Total 10,725 lbs Original Cost: $24,520.79 Condition: They appears to be in good condition. Location: One transformer is on the concrete pad behind the X-533A Switch Yard and all others are in the X-533A Switch Yard. 13

BUS DUCT SYSTEM Capabilities: This configuration offers superior strength as well as reduced weight when compared to steel or copper rectangular designs. Provides equalization of reactance between phases no phase transposition is required on long runs. Description: A 13.8 KV bus duct system from transformer to building. Serial Numbers: N/A In Service: 5/31/1955 Quantity: 1 system. Original Cost: $2,455,204.84 Condition: Good working condition. However, it is past its life cycle. Location: X-533A Switch Yard. 14

A HEATING AND VENTILATING SYSTEM Capabilities: Uses a fan to force air through air ducts to create ventilation. Steam coils are routed near the fan to produce heat when it is cold. Steam can be turn on or off according to the need. Oil is used as a filtering system. Description: Heating and ventilation system. In Service: 2/28/1955 Life Cycle: 35 yrs. Quantity: 2 systems and unknown number of feet for ventilation duct. Weight: Original Cost: $162,251.07 Condition: They appear to be in fair condition and is currently in working condition. However, they are past their life cycle. Location: One in each Switch House of X-533B. 15

LIGHTING SYSTEM Capabilities: To provide adequate lighting throughout the switchyard for work to be performed during limited visibility periods. Description: An interior electric lighting system. In Service: 3/31/1957 Life Cycle: 30 yrs. Quantity: 1 system. Weight: N/A Original Cost: $285,732.01 Condition: It appears to be in fair condition and is currently in working condition. However, it is past its life cycle. Location: Both X-533B Switch House buildings and control building. 16

FIRE ALARM SYSTEM Capabilities: System contains manual and automatic alarm initiators. The system contains an audible warning and uses water for fire suppression and/or containment. Description: Fire Alarm System (Switchhouse). Two separate systems tied together for alarm. In Service: 2/28/1955 Life Cycle: 35 yrs. Quantity: 1 system. Original Cost: $147,822.37 Condition: Appears to be in fair condition and is still being relied on. However, it is past its life cycle. Location: X-533 Complex. 17

CONDENSER SYNCHRONOUS - Large Capabilities: An apparatus for controlling voltage flicker in power distribution in a substation, comprising a synchronous condenser, a field adjuster for the synchronous condenser and a compensation circuit, apparatus being adapted to compensate the distribution voltage flicker due to a large load variation in substation and being able to adjust a predetermined distribution voltage within an allowable range. Description: Condenser Synchronous Serial Numbers: 6999723, 6920463, 6920464, 6999724 In Service: 6/30/1955 Quantity: 4 units. Weight: Estimated 240,000 lbs Original Cost: $855,948.22 Condition: Appears to be in fair condition. Location: X-533B. There are two at the top of each Switch House. 18

SWITCHGEAR UNIT SUBSTATION 480 VOLTS Capabilities: A switchgear is used both to de-energize equipment to allow work to be done and to clear faults downstream. Description: Switchgear Unit Substation 480 Volt 3/phase Serial Number: 31525 In Service: 6/30/1955 Quantity: 2 systems. Original Cost: $17,876.86 Condition: Appears to be in good condition. Location: One in each Switch House at X-533B. 19

CONDENSER SYNCHRONOUS Capabilities: An apparatus for controlling voltage flicker in power distribution in a substation, comprising a synchronous condenser, a field adjuster for the synchronous condenser and a compensation circuit, apparatus being adapted to compensate the distribution voltage flicker due to a large load variation in substation and being able to adjust a predetermined distribution voltage within an allowable range. Description: Condenser Synchronous 25000 to 31250 Serial Numbers: 6-S-10088, 6-S-10088, 3-S-10088, 2-S-10088, 5-S-10088, 4-S-10088 In Service: 6/30/1955 Quantity: 6 units.. Weight: Estimated 140,000 lbs Original Cost: $287,743 to $295,657 Condition: Appears to be in fair condition. Location: X-533B. There are three at the top of the East/West Switch House. 20

SYNCHROSCOPE Capabilities: In AC electrical power systems, a synchroscope is a device that indicates the degree to which two systems (generators or power networks) are synchronized with each other. Synchroscopes measure and display the frequency difference and phase angle between two power systems. Description: Synchroscope (including meters fuses) Serial Numbers: N/A In Service: 6/30/1955 Life Cycle: 25 yrs. Quantity: 3 units. Original Cost: $1,291.85 Condition: 2 appear to be in fair condition and one is in poor condition. Location: X-533B Control Room. 21

INVERTER W/ 5 HP MOTOR Capabilities: This inverter is capable of running any load within its wattage range. Description: Inverter with 5HP Motor MODEL 5A51-25 Serial Number: 6931331 In Service: 6/30/1955 Life Cycle: 15 yrs. Quantity: 1 unit. Original Cost: $2,199.16 Condition: It appears to be in fair condition. Location: X-533B Carrier Room, West Switch House. 22

TRANSFORMER DRY TYPE Capabilities: Dry type simply means it is cooled by normal air ventilation. The dry type transformer does not require a liquid such as oil or silicone or any other liquid to cool the electrical core and coils. Description: Transformer - A 2400/480 Dry Type Transformer Serial Numbers: KY In Service: 4/30/1986 Quantity: 2 system. Original Cost: $12,111.60 Condition: Appears to be in good working order with a life cycle that expires in 2026. Location: One in each X-533B Switch House. 23

GENERATOR - DC Capabilities: In a direct current generator, the purpose is to change the alternating current (AC), which flows into its armature, into direct current. Description: Generator DC Motor Emergency 250 VDC Serial Numbers: 74415, 74416 In Service: 6/30/1955 Life Cycle: 20 yrs. Quantity: 1 unit. Original Cost: $3623.01 Condition: It appears to be in fair condition and is past original life cycle. Location: Downstairs of X-533B Control Building 24

DIRECT WRITING OSCILLOGRAPH Capabilities: A recorder in which the permanent record of varying electrical quantities or signals is made on paper, directly by a pen attached to the moving coil of a galvanometer or indirectly by a pen moved by some form of motor under control of the galvanometer. Also known as mechanical oscillograph. Description: Oscillograph Direct Writing 12-Channel In Service: 5/31/1970 Life Cycle: 25 yrs. Quantity: 1 unit. Original Cost: $66,090.71 Condition: It appears to be in good condition. Location: X-533B Control Room. 25

TRANSFORMER 2500 KVA Capabilities: Each transformer is large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer Power 2500 KVA 13.8 KV/2 Serial Numbers: 31126TRANS-1, 31126TRANS-2 In Service: 6/30/1955 Quantity: 2 units. Original Cost: $14,348.10 Condition: They appear to be in good condition even though past life cycle Location: X-533B East/West Switch House. 26

TRANSFORMER 2300/480 Volt Capabilities: Each transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer 2300/480 VOLT 300 KVA In Service: 6/30/1955 Quantity: 2 units Original Cost: $7,257.46 Condition: They appear to be in good condition even though past life cycle Location: X-533B East/West Switch House. 27

TRANSFORMER 150 KVA Capabilities: Each Transformer is a large encased group of metal plates about the size of a small house with 2 sets of insulated copper wires wrapped around the plates -an input and output - to convert a very high supply line voltage to a lower voltage. Description: Transformer 150 KVA Lighting Stockwell, Serial Numbers: 15606, 15607, 15608 15609, 15605 In Service: 6/30/1955 Quantity: 5 units. Original Cost: $2,727.39 Condition: They appears to be in good condition even though past life cycle Location: X-533B East/West Switch House. 28

OSCILLOGRAPH RECORDING FAULT Capabilities: An oscillograph measures variations of electric current by having it go through a magnetic coil. Variations in current induce momentum in the coil, which can be directly measured. Description: Oscillograph A Recording Fault System Serial Number: 16658 In Service: 10/31/1986 Life Cycle: 25 yrs. Quantity: 1 units. Size: In a cabinet Original Cost: $88,960.67 Condition: Appears to be in good working condition Location: X-533B Control Building 29

AIR COMPRESSOR UNIT Capabilities: A compressor takes in air at atmospheric pressure and delivers it at a higher pressure. This pressure is used to operate the three phase switchgears in a substation. Contains pump and air tank. Description: Air Compressor Unit With Compressor Serial Numbers: 10120, 10121, 10126, 10124, 10123, 10122, 10125, 10127, 10137, 10138, 10140, 10139, 10142, 10141, 10131, 10135, 10135, 10136, 10132, 10134, 10133, 10130, 10128, 10129, 10143. In Service: 6/30/1955 Quantity: 24 units. Original Cost: $9,442.46 Condition: They appear to be in fair working condition. Location: East/West X-533B Switch Houses. 30

MAIN CONTROL BOARDS Capabilities: Monitors and controls the power of the switchyard. Description: Main Control Boards - A System of Control In Service: 6/30/1955 Quantity: 1 system. Original Cost: $1,395,613.95 Condition: Appears to be in good condition. Location: X-533B Control Room. 31

SWITCHGEAR 13800 VOLTS Capabilities: Each high voltage switchgear is any switchgear used to connect or disconnect a part of a high-voltage power system. These switchgear are essential elements for the protection and safe operation, without interruption, of a high voltage power system. This type of equipment is important because it is directly linked to the quality of the electricity supply. Description: Switchgear 13,800 VOLT W/11 Air Receiver In Service: 6/30/1955 Quantity: 13 units. Original Cost: Varies from $418,288.69 to $503,167.69 Condition: They appear to be in fair condition. Location: X-533A. On top of East/West Switch House. 32

OIL TANK 15,000 GALLON Capabilities: They purpose is to store mineral oil in order to be used by transformers. Description: Tank Oil Storage 15000 gallon capacity In Service: 2/28/1955 Quantity: 2 units Original Cost: $6,001.50 Condition: They appear to be in good shape. Location: X-533A (West End) 33

OIL TANK 34,000 GALLON Capabilities: They purpose is to store mineral oil in order to be used by transformers. Description: Tank Oil Storage 34000 gallon capacity In Service: 2/28/1955 Quantity: 2 units. Original Cost: $10,923.50 Condition: They appear to be in good condition. Location: X-533A (West End) 34

OIL FILTERING SYSTEM Capabilities: Contained mineral oil to heat and pump oil through transformers in order to filter out impurities. Description: Oil Filtering System with minor tank In Service: 8/31/1974 Life Cycle: Unknown Quantity: 1 system Original Cost: $65,696.07 Condition: It appears to be in good working condition Location: X-533A (West End) 35

AIR CONDITIONER - WINDOW Capabilities: They re-circulate and cool air to regulate temperature in Control Room. Description: Air Conditioner 220 Volt Friedrich In Service: Unknown Life Cycle: Unknown Quantity: 2 units. Original Cost: Unknown Condition: They appear to be in good working condition and are working. Location: X-533A Control Building 36

LUBE OIL PUMPS Capabilities: Pump oil and create oil pressure into the synchronous condenser. It moves middle of synchronous condenser into place until the rotation speed will hold it by itself. Description: Lift and lube oil pumps In Service: Unknown Life Cycle: Unknown Quantity: 8 systems Original Cost: Unknown Condition: They appear to be in fair working condition. Location: X-533B East/West Switch House. 37

Heating and Vent Fan Capabilities: The substation ventilation is designed to optimize air circulation over and around the transformers and through the panel compartment so that the substation operates at lower temperatures. Description: Heating and Vent Fan In Service: 3/31/1957 Life Cycle: 30 yrs.. Quantity: 1 system Original Cost: $162,251.07 Condition: It appears to be in good working condition Location: X-533B West Switch House 38

Hot Water Heater Capabilities: A heating system that uses steam generated from a boiler. The steam heating system conveys steam through pipes to heat exchangers, such as radiators, convectors, radiant panels, or fan-driven heaters, and returns the resulting condensed water to the boiler. Such systems normally operate at pressure not exceeding 15 lb/in.2 gage or 103 kilopascals gage, and in many designs the condensed steam returns to the boiler by gravity because of the static head of water in the return piping. With utilization of available operating and safety control devices, these systems can be designed to operate automatically with minimal maintenance and attention. Description: Steam Fan In Service: Unknown Life Cycle: Unknown Quantity: 16 yrs. Original Cost: Unknown Condition: Condition varies from poor to good. Location: X-533B East/West Switch House 39

ELECTRIC HEATER Capabilities: A device for heating rooms that converts electric current to heat by means of resistors that emit radiant energy. Resistors may be composed of metal-alloy wire, nonmetallic carbon compounds, or printed circuits. Heating elements may have exposed resistor coils mounted on insulators, metallic resistors embedded in refractory insulation and encased in protective metal, or a printed circuit encased in glass. Fins may be used to increase the area that dissipates the heat. Description: 480 Volt Heater In Service: Unknown Life Cycle: Unknown Quantity: 16 yrs. Original Cost: Unknown Condition: They appear to be in good working condition Location: X-533B East/West Switch House. 40