Utility Battery Chargers DC Power Systems Custom Design

Similar documents
R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

EPIC SERIES CONSOLE 2.0 EPIC YOUR DC SYSTEM ANYWHERE. hindlepowerinc.com JF Rev

FLOAT BATTERY CHARGERS

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Intelligent Single Loop Fire Alarm Control Panel

Intelligent 2 & 4 Loop Fire Alarm Control Panels

ENGINE GENERATORS AND ACCESSORIES

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

B. Section Transfer Switches: Automatic transfer switch.

Digital Control Systems & Remote Communications Options

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

4Up to 40kW per sq. ft. (24 kw per sq. ft.) 4Modulating, ON/OFF or staging 4Standard from 0.5 to 1000 kw, larger loads available

Rack Mount Series Installation Guide

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Variable Frequency Drive SERIES MP800 VFD

For Complete Fire and Gas Solutions

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

DIESEL Engine Fire Pump Controllers Features

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

BLAZE 400G TURBO & BLAZE 600D TURBO I & Input BTU/h: 399,000 (400G), 575,000 (600GT & 600GTII) Indirect NG/LP Beckett Burner

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

SECTION POWER SUPPLIES AND DISTRIBUTION

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

Annunciation, Remote Monitoring, Control Industrial Control Panels

TPSD. Installation and Operation Manual. Filtered Battery Charger Power Supply / Battery Eliminator

Industrial Grade Gas Detection

21-light Remote Annunciator. Owner s Manual

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual

Industrial Grade Gas Detection

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

RACO's Verbatim Gateway keeps you in touch, and in control, no matter where you are.

CommStat 4 Controller

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

La Marche Manufacturing Company A36D. Battery Charger / Power Supply. Installation and Operation Manual

Across-the-Line SERIES MP300 Combined Manual and Automatic

INSTALLATION INSTRUCTIONS

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

Security CCTV System Construction Checklist

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

To find your nearest dealer go to: LEBE /13

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Technical Data Submittal Documents

VA301C CONTROLLER WITH BACnet OPTION

DIESEL Engine Fire Pump Controllers Features

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Soft Start Series MP700 Solid State, Reduced Voltage

STATEMENT OF WORK I. SCOPE OF WORK:

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Power Supplies. Overview

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

for Drinking Water Systems

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Control Panel with Across The Line Starters

Commercial and Light Industrial Fire Alarm Control Panel

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

Blower-YEFB-020-3R-1maxVel

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

your dust explosion protection experts

Spectron LSN (Life Safety Network) Suggested Specifications

SP40S-D. Kingfisher Company, inc. Features: Description:

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

FTA550 JOCKEY PUMP CONTROLLERS

Circulating Water Temperature Controller

MULTIFUNCTIONAL SYSTEM

Model 4001 Series Single Channel Controller

WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

SEALED ENCLOSURE COOLING

Industrial Grade Gas Detection Detecting The Difference

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

GasGard 100 Control System

NOTIFIER TECH TIPS. The Fire Panel displays an isolate that is listed as an Unknown Point or Unnamed Point

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Model A2100 Series Annunciator

Transcription:

Utility Battery Chargers DC Power Systems Custom Design

Hindle Transformer Company founded 1948 Hitran Corporation Flemington, NJ HindlePower, Inc. Easton, PA, Incorporated 2000 40,000 sq. ft. Facility 75 Employees

Product Line Portfolio

Quality Charger Products Made in U.S.A. AT Series- Microprocessor Controlled AT10.1 Single-phase input AT30 Three-phase input SCR Analog controlled single & three-phase UMC Universal Maintenance Charger Single Cell Service Charger EPIC Series Consoles DC Power Cabinets Mobile DC Power Systems Trailers Custom Engineering

Charger Overview

Classic Workhorse Single and 3 Phase 12-260 Vdc 6-1,000 Adc Quality Charger Products Made in U.S.A.

The AT Series Microprocessor Controlled Battery Charger Single (AT10.1) and 3 Phase (AT30) models for almost any application Communications Module for Remote Monitoring Can Include a Breaker Panel for Power Distribution (AT-DC)

Many Output Options 12, 24, 48, 130 Vdc Single Phase Current (AT10.1) 6, 12, 16, 20, 25, 30, 40, 50, 75, 100 3 Phase (AT30) Current 25, 30, 40, 50, 75, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000

The AT Series Standard Product Features Microprocessor Controlled with Digital LED Display Universal Control Board Standard Alarms: High DC and Low DC, DC Output Failure, AC Input Failure, (+) Ground,( - ) Ground Forced Load Share Remote Voltage Sense Patented Safety Shield 5-Year Standard Warranty

Selectable Meter Settings or auto cycle through configuration Feature Rich and Easy to Use 1% digital meter indicate voltage, current, equalize time and error codes. Selectable Float or Equalize setting or a mode indicator. Equalize method manual or automatic LEDs Alarm Indicators Simple adjustments Easy Edit Charger Settings

Communications Module: Full SCADA Integration and Remote Capabilities DNP3 Level 2 and Modbus Protocols Serial or Modem Communication Simple add-on card

Battery Charger Communications What functionality does the communications option provide? Provides status of DC system to SCADA (Supervisory Control and Data Acquisition) system voltage, current, temperature, alarms, charger status/error codes Permits remote control of the charger including set point changes

The PlexiShield The ONLY Patented Safety Shield in the industry Offers secure access to the inside of the

The HindlePower Microprocessor Pioneered Microprocessor Advantage Charger technology in 1992 Universal Control Board for the entire AT SERIES product line Easiest charger to use on the market: No hidden menus or codes Front panel control lock out standard Individual Alarm Lamps standard Remote Voltage Sense and Load Share included Complete Self-Diagnostics from Start-Up through Operation Superior Customer Service Proudly manufactured in the USA Standard 5 -Year Product Warranty

UMC Universal Maintenance Charger Works with any Battery from 24 130 VDC 25 or 50 Amp Output Current Limit 10%- 110% Built-in Battery Eliminator

The Single-Cell Charger Charge a Battery Cell Without Removing it From Service Restore Battery Cell Balance

EPIC CONSOLE EPIC ENGINEERED POWER INTEGRATED SYSTEM

EPIC CONSOLE DESIGNED FOR STATION BATTERIES AND CHARGER FULLY ENGINEERED, ASSEMBLED TESTED PRIOR TO SHIPPING 5 YEAR LIMITED WARRANTY

EPIC CONSOLE RUGGED ALL STEEL CONSTRUCTION DURABLE POWDER COAT PAINT EPOXY FINISH DESIGNED IN CONFORMANCE WITH NEMA 1, 2 AND 3R SEISMIC ZONE 4 QUALIFIED

EPIC CONSOLE TOP AND BOTTOM VENT FOR CONVECTION AIR CIRCULATION THERMOSTATICALLY CONTOLLED FAN AND HEATER STRIPS OPTIONAL AIR CONDITIONER SIDE-MOUNTED INTERIOR SEALED LED LIGHTING

Mobile DC Power System

Primary Applications Battery and DC System Maintenance & Testing - NERC Compliance Disaster Recovery / Black Start DC Power System Redundancy

AC Annunciator Control Panel External Wall-Mount AC Power Diagnostics: Voltmeter Ammeter Alarm Indicators Mimic Panel Format AC Power Receptacles Circuit Breaker Protection Trailer equipped with 240Vac, single-phase input Supplemental 120Vac input option available

DC Annunciator Control Panel External Wall-Mount DC Power Diagnostics: Voltmeter Ammeter Alarm Indicators Mimic Panel Format DC Power Receptacles Circuit Breaker Protection

Generator Tongue-mounted with clam-shell, padlockable enclosure 5-6KW typical 240Vac, 1-phase. Other output voltages available

Climate Control Thermostat-controlled convection heating and/or optional roofmounted A/C available

For more product details visit us at... www.hindlepowerinc.com or call us at 610-330-9000