Liebert Datamate: R-407C Parts Manual

Similar documents
Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

Liebert CRV Parts Manual

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Liebert Mini-Mate2 1 To 8 Tons

Liebert Mini-Mate2 1 To 8 Tons

Liebert Mini-Mate2 1 To 8 Tons

Liebert Deluxe System (DH) Deluxe System Family

Liebert. Mini-Mate2 1 To 8 Tons Overhead Precision Cooling And Humidity Control

VertiCool Aurora Engineering Guide

Liebert OVERHEAD COOLING IN A VARIETY OF CAPACITIES AND CONFIGURATIONS. Mini-Mate2. 1 to 8 Tons. Provides Precision Cooling And Humidity Control

C13-Series Engineering Guide

Liebert CSU3000 Chiller

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Liebert CRV Warranty Inspection Check Sheet

Humidifiers Dealer Parts List

Liebert DataMate (1-3 Ton) Warranty Inspection Check Sheet

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Environmental Control

Humidifiers. Model 400/400M Humidifiers NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO.

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

CoolSpot Engineering Guide

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

ACHIEVING ENERGY-EFFICIENT DATA CENTER COOLING: DOES REDUCING FAN SPEED ALWAYS RESULT IN ENERGY SAVINGS?

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual

Handout Book Additional information with exercises charts forms, etc. TM /02

Liebert PDX and PCW Thermal Management Systems

IPAC Air Handling Units

mn Dometic KRA Refrigeration Price and Parts Guide

Humidifiers Dealer Parts List Model 400/400M Humidifiers

Liebert Mini-Mate Thermal Management Systems

REPLACEMENT PARTS MANUAL

Air Cooled Scroll Compressor Condensing Unit

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Ice Making Equipment Illustrated Parts Lists

Liebert Prop Fan Condensing Unit

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

VK 3-30 Tons. R407C Data. Vertical Comfort Cooling A/C s & Heat Pumps. 3 to 30 Tons. VK Veritical Cooling Comfort air conditioners (AVK-R7-L25)

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

ENGINEERING SPECIFICATIONS

C0322 and C0522 Service Parts

ENGINEERING SPECIFICATIONS

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Liebert Challenger 3000

(EE1500, EE2000, EE2500, EE3000)

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Flexible & Innovative. Cooling Solutions

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

CU0415, CU0715 and CU0920 Service Parts

SERVICE PARTS for ECO353N

Cleveland Range Inc. COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT. Cleveland General Specifications. Cleveland Standard Features

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

Air-Cooled Condensing Units with Compact Screw Compressors

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

RP8.1Y (ERRATA 1) (202) 2 of 8

NEXT DL NEXT DL. rcgroupairconditioning

Liebert Challenger 3000/Liebert Challenger ITR with Liebert icom Control. Operation & Maintenance Manual - 50 & 60Hz

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

AIR HANDLER DESIGN WORK SHEET

Installation Manual BCS 1000/1500

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

Liebert Mini-Mate2 Air-Cooled Model

CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION

Installation Manual BCS2000/3000

MAC N-407 Air-Cooled Chiller

CMS1402 SERVICE PARTS

Advance Release September 2009

REPLACEMENT PARTS MANUAL

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL

Next Generation Critical Cooling for Room and Row. Liebert PEX Ef ciency And Reliability For High Availability Cooling. Compressor Models User Manual

Marvel S MICROPROCESSOR CONTROLLER. Installation, Operation and Maintenance Manual Effective October 2018 DISCONTINUED. For Reference Only

Precision Air-Conditioning Units 60 Hz. Technical Data

Spare Parts Catalogue MV1006

MACH N-407 Heat Pump Air-Cooled Chiller

MDT2 Service Parts. Table of Contents Cabinet Page 2. Condensing System Page 3. Water and Dispensing Page 4. Water and Dispensing Part Numbers Page 5

REPLACEMENT PARTS MANUAL

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet

CME1856W Service Parts

Call us today! (800)

GUIDE SPECIFICATIONS AQUARIUS ii

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

RSMSD Technical Guide

Installation, Start-Up and Service Instructions

Transcription:

Liebert Datamate: R-407C Parts Manual While every precaution has been taken to ensure accuracy and completeness in this manual, Vertiv Co. asssumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 2016 Vertiv Co. All rights reserved throughout the world. Specifications subject to change without notice. Vertiv and the Vertiv logo are the registered trademarks of the Vertiv Corporation.

Table of Contents 1. Product Description... 1 2. Model Number Definition... 2 3. Coil Section... 3 3.1. DX... 3 3.2. CW... 3 4. Electrical Section... 4 4.1. Reheat and Humidifier... 4 4.2. DBMP... 5 5. Humidifier Section... 6 5.1. Main Assembly... 6 5.2. Humidifier Assembly... 7 6. Exterior Section... 8 7. Piping Section... 10 7.1. Chilled Water... 10 7.2. DX... 11 7.3. Water In Assembly... 11 7.4. Water Out Assembly... 12 8. Parts Gallery... 13 9. Revision Page... 15 ii Confidential Document Released 01/2011

Product Description 1. Product Description The DataMate is a split system air or water/glycol cooled unit or self-contained chilled water unit. The evaporator section includes the blower assembly, filter, microprocessor control, and electric reheat. All evaporator sections are 208/230 Volt 1-phase. A cooling-only model is also available. Air cooled units - include the evaporator section plus one of the following condensing units. (Design ambient 95 F (35 C).) MCD Centrifugal fan unit includes scroll compressor, factory mounted disconnect switch, condenser coil, centrifugal blower assembly, high pressure switch, Lee-temp head pressure control system, hot gas bypass, and filter drier. Unit must be mounted indoors. Duct flanges are provided. (See pricing for voltages). Prop fan unit which includes scroll compressor, condenser coil, prop fan, high pressure switch, Lee Temp head pressure control, filter dryer, hot gas bypass, and sight glass. Unit is designed for outdoor location (see pricing for voltages). (Consult the Prop Fan Condensing Unit Price Book for optional selections). DMC Water/Glycol cooled includes the evaporator section plus a water/glycol cooled condensing unit which includes compressor, condenser, two-way water regulating valve, filter dryer, and sight glass. Design pressure is 1034 kpa (50 psi). Condensing unit is designed to mate up to evaporator section to create a self-contained system. (See pricing for voltages.) Drycooler(s) and pump(s) selected separately. MCD Water/Glycol Condensing Unit includes a scroll compressor, factory mounted disconnect switch, coaxial condenser, two-way or optional three-way water regulating valve, hot gas bypass, and filter drier. Design pressure is 150 psi (1034 kpa) or optional 350 psi (2413 kpa). (See pricing for voltages and complete model number). Drycooler(s) and pump(s) selected separately for applications using glycol loop. Drycooler and pump selected separately. Chilled water fan/coil section includes chilled water coil and two-way slow close valve. Design pressure is 125 psi (862 kpa). Humidifier. Steam-generating type with electronic control and automatic flushing circuit, humidification and dehumidification control, strainer, inlet drain, and solenoid valves and controls for humidification and dehumidification. Condensate Pump. Can be field installed in the base of the unit. The pump is supplied with discharge check valve. Pre-charged refrigerant line set. Contains an insulated copper suction line and a copper liquid line for interconnection of the indoor and outdoor sections. Available in 15 foot (4.5m) and 30 foot (9m) sections. Refrigerant-Line sweat adapter kit. Contains two suction and two liquid line compatible fittings that allow field-supplied interconnecting refrigerant lines to be used. See Installation, Operation & Maintenance Manual for maximum recommended installed distances. Product Description March 2010 iii 277 Volt System requires two field installed transformers (37.5 amps each). One for evaporator module and one for condensing module. For self-contained water/glycol system: consult factory for required transformer. The transformer is epoxy encapsulated and is suitable for indoor/outdoor installation. Released 01/2011 Confidential Document 1

Liebert Datamate: R-407C 2. Model Number Definition 2 Confidential Document Released 01/2011

Coil Section 3. Coil Section 3.1. DX Item Part # Description 1.5T 2T 3T 124105G1 COIL EVAP DM 1.5T 12X29.31X3.5 1 1 1 1 124105G2 COIL EVAP DM 2T 12X47X2.62 1 1 1 124105G3 COIL EVAP DM 3T 12X47X3.5 1 1 1 3.2. CW Item Part # Description 1.5T 2T 3T 1 130886G1 COIL CW 2T DME 1 25 P02-0290 VALVE CORE REFRIGERANT 1 Released 01/2011 Confidential Document 3

Liebert Datamate: R-407C 4. Electrical Section 4.1. Reheat and Humidifier Item Part # Description 1.5T 2T 3T 3 1D16378P20 SAFETY STAT REHEAT DM 1 2 2 8 E03-0170 RELAY 1P2T 24V 50/60HZ 2 2 2 9 121187P1 PWRBLK 2PL 1)2:14X6)10:18 QC 1 1 1 11 E03-0010 XFMR 075VA 5060 208/30/77-24 1 1 1 12 E-276C CB 3.2A BRKT MNT ETA 1 1 1 13 E-362B TERM LUG MECH #14-2/0 1/4" 1 1 1 16 132487P2 TERMLSTRIP SECTION END BARRIER 2 2 2 17 132487P1 TERMLSTRIP SECTION 1 POS 19 19 19 38 131116P1 RELAY ELECTRIC HEAT 1 1 1 41 124133P1 BRKT CNTL BOX MTG DM 1 1 1 52 149749P1 STANDOFF.250" FOR.156" HOLE 2 2 2 53 415771G1 PWA CONTROL BOARD MM2 1 1 1 4 Confidential Document Released 01/2011

Electrical Section 4.2. DBMP Item Part # Description 1.5T 2T 3T 4 E-362B TERM LUG MECH #14-2/0 1/4" 1 1 1 5 1C21105P1 CONTACTOR 2PL 24V 1 1 1 11 1A19542P1 BRKT CAP MTG 2.00" DIA 1 1 1 E12-243A BRKT CAP MTG 2.00" DIA 1 1 1 12 132487P1 TERMLSTRIP SECTION 1 POS 19 19 19 13 132487P2 TERMLSTRIP SECTION END BARRIER 2 2 2 19 121187P1 PWRBLK 2PL 1)2:14X6)10:18 QC 1 1 1 Released 01/2011 Confidential Document 5

Liebert Datamate: R-407C 5. Humidifier Section 5.1. Main Assembly Item Part # Description Voltage 20E 27E 37E 44C 1 Humidifier Assembly on Page 4 124220P1 Hose Steam 0.88ID 10PSI 5 124216P2 CLAMP HOSE WORM DRIVE.31 X 1.25 6 Confidential Document Released 01/2011

Humidifier Section 5.2. Humidifier Assembly Item Part # Description Voltage 20E 27E 37E 44C 1 134562P1 PWA CNTL ELEC RELAY HUM 2STG 208/30-60- 1 2 127849P1 BOTTLE HUM 1PH 220/277 5 LBS 3 127853P1 XFMR TORROID HUM 5T MME 4 136812P1 VALVE SOL/STRNR HUM FILL 24V 208/30-60- 1 5 127992P1 VALVE SOL DRAIN KIT HUM 24V 6 E03-0170 Relay 1P2T 24V 50/60HZ 7 128759P1 BOOT RUBBER SG HUM TERM COVER 2 2 2 2 Released 01/2011 Confidential Document 7

Liebert Datamate: R-407C 6. Exterior Section Item Part # Description Voltage 20E 27E 37E 44C 1 131111P1 PANEL CAB TOP 16GA CRS 62.88 1 1 131111P2 PANEL CAB TOP 16GA CRS 45.25 1 2 131110P1 PANEL CAB UP FR 16GA CRS 62.88 1 1 1 131110P2 PANEL CAB UP FR 16GA CRS 45.25 1 3 132483P1 PANEL CABINET LOWER FR 63" DM 1 1 1 132483P2 PANEL CABINET LOWER FR 45 " DM 1 4 124079P1 PANEL CABINET LEFT SIDE DM 5 124079P2 PANEL CABINET RIGHT SIDE DM 6 124081P1 PANEL FRAME SERVICE 63 " DM 1 1 1 8 Confidential Document Released 01/2011

Exterior Section Item Part # Description Voltage 20E 27E 37E 44C 124081P2 PANEL FRAME SERVICE 45 " DM 1 8 183916P1 FILTER AIR ASSY BLACK 1.5T DME 1 183917P1 FILTER AIR ASSY BLACK 2&3T DME 1 1 1 9 131108G2 GRILL AIR RETURN ASSY DME 2/3T 1 1 1 131108G4 GRILL AIR RETURN ASSY DME 1.5T 1 10 131108G1 GRILL AIR DISCH ASSY DME 2/3T 1 1 1 131108G3 GRILL AIR DISCH ASSY DME 1.5T 1 13 1D16378P63 LOCK PANEL DMATE 2 2 2 2 17 124144P1 SUPPORT FRONT SERVICE PANEL DM 2 3 3 3 23 131109P1 BEZEL DM CONTROL Released 01/2011 Confidential Document 9

Liebert Datamate: R-407C 7. Piping Section 7.1. Chilled Water Item Part # Description 2T 3T 1 PIPG WATER IN DME CW 2/3T on Page 11 2 PIPING WATER OUT DME CW 2/3T on Page 12 3 S-0140 INSULATION TUBE 3/8"WALL 7/8" 4 4 8 P02-0290 VALVE CORE REFRIGERANT 1 1 10 Confidential Document Released 01/2011

Piping Section 7.2. DX Item Part # Description 2T 3T 1 PIPING WATER OUT DME CW 2/3T on Page 12 2 124164G2 SUCTION ASSY 1/2 1.5T DM R407C 1 1 3 F20-2300 BRKT COND PUMP ADJ-PART B 2 2 15 191314P1 TUBE STR CU1/4X.028X22.00 B/S 1 1 16 P-229C CLAMP INSULATED METAL 3/8" 1 1 7.3. Water In Assembly Item Part # Description 2T 3T 3 127585P2 VALVE H2O SLOW 2WAY 3/4" 8CV 1 1 4 P-0800 ELL 90 FTGXC 7/8" CU 1 1 5 187933G2 VALVE ACC BODY 1/4 EXT1" BEAD 1 1 Released 01/2011 Confidential Document 11

Liebert Datamate: R-407C 7.4. Water Out Assembly Item Part # Description 2T 3T 3 P-0800 ELL 90 FTGXC 7/8" CU 1 1 5 134648P1 TUBE FORM CU 7/8 WTR 1 1 199793P1 TUBE FORM CU 7/8 WTR 1 1 12 Confidential Document Released 01/2011

Parts Gallery 8. Parts Gallery Electrical Section 1C21105P1 1D16378P20 121187P1 124133P1 131116P1 132487P1 132487P2 415771G1 E03-0010 E03-0170 E-276C E-362B Humidifier Section 100281 124216P2 124220P1 127849P1 148250P2/3 127935P1 127935P5 167770P1 136812P1 E03-0170 P02-0020 Released 01/2011 Confidential Document 13

Liebert Datamate: R-407C Exterior Section 1D16378P63 124079P1 124079P2 124080P1 124081P1 124143P1 124144P1 124145P1 131108G1/3 131108G2/4 131109P1 131110P1 131111P1 132483P1 167442P1 183916P1 Piping Section 124164G2 127585P2 180716P3 180806P1 187933G2 191314P1 F20-2300 P02-0290 P03-0030 P-229C 14 Confidential Document Released 01/2011

Revision Page 9. Revision Page Revision Date Modification Details 01/2011 Manual Release Released 01/2011 Confidential Document 15