RL with INNOVATOR Doors

Similar documents
RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

LifeLine Premier RLNIE

RL with INNOVATOR II No Heat Doors

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

RLNIE with INNOVATOR II

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLT with INNOVATOR Doors

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

Engineering Plan Views

RMN with INNOVATOR Doors Technical Data Sheet

P/N _F NSF Certified June 2010

RM with INNOVATOR Doors

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FG-L Technical Data Sheet

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

LWU Technical Data Sheet

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

PWEE Technical Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

Nosing Heater. Return Grill Heater

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

Installation & Service Manual

HGL- 1, 2 & 3 BS, TS Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers

Installation & Service Manual

Mini-Combo id. Model MCH. Installation and Operation Instructions. Induced Draft Residential Gas-Fired Space/Water Heater

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

Installation & Service Manual

NFW, NCW, NFWG, NCWG, NFWE, NCWE

Installation & Service Manual

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

F-6 Multi-deck Frozen Food Wall Merchandisers

Reach-in Merchandisers

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

Installation Instructions

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

Electric Heat Accessory

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

TO DO IF YOU SMELL GAS

Description/ Application

MD Medium Temperature Self Contained Open Vertical Merchandisers

SQ3CD, SQ4CD, SQ5CD, SQ6CD, SQ8CD

BCH Medium Temperature Merchandisers

Medium Temperature Bulk Produce and Bakery Merchandisers

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

FEDERAL INDUSTRIES IMSS60, IMSS84 & IMSS120 MODELS INSTALLATION & OPERATIONS MANUAL

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

LOW PROFILE UNIT COOLER

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

RFLNS, RFMNS & RFLTM Freedom Line

LOW PROFILE UNIT COOLER

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

MD Medium Temperature Self Contained Open Vertical Merchandisers

HIGH-EFFICIENCY CONDENSING UNITS

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT

Parallel Rack Systems

HGM-1, 2 & 3 BS, TS Bottom / Top Mount Medium Temperature Remote and Self Contained

N5FGA, N5NGA, N5FGNA, N5NGNA

Hoshizaki America, Inc.

IOM 410. Installation Operation Maintenance Information. UNIT COOLERS Super-Flo (SD Models) Easy-Flo (EF Models) Table of Contents

Service Merchandisers

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Installation and Operation Manual

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

Field Top Mounted Condensing Unit

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

Installation & Service Manual

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

Service Merchandisers

Transcription:

Merchandisers K L with INNOVATO Doors Technical Data Sheet /N 042544_M NSF Certified July 200 E Warning: Terminal block NOT for case-to-case wire connection! J A D F G C I H We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item art # Description Wiring Item # FAN ASSEMLIES, AND THEMOSTATS A. 12W Standard Fan Assembly 004000 Fan Motor, Evaporator (1) (MO.441010) 041805 Fan lade (F.48044) 12W Optional Energy Efficient Fan Assembly (1) 0455 Fan Motor, Evaporator (MO.441054) 041805 Fan lade (F.48044). 0440 Standard Non-adjustable (2) Defrost Thermostat (CT.44402) C. Optional Adjustable efrigeration Thermostat () D. 0442 Defrost Limit Thermostat (4) (CT.444021) E. 041814 elay Control Thermostat or (5) Fan and Anti-sweat Heater Thermostat (CT.448129) ELAS F. 042598 Anti-Sweat Control elay () (L.448028) G. 042599 Fan Control elay (208V) () (L.44802) HEATES H. Electric Defrost Heaters Front (208V) (8) 048412 (1) 1 Door Models (HE.48502) 044155 (1) 2 Door Models (HE.48504) 04415 (1) Door Models (HE.4850) 04415 (1) 4 Door Models (HE.48504) 044158 (1) 5 Door Models (HE.48502) NOTE: evision M adds more LED lighting data. 200 HUSSMANN COOATION IDGETON, MO 044-248 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM Item art # (Qty) Description Wiring Item # HEATES (CONTINUED) H. Electric Defrost Heaters ear (208V) (8) 04841 (1) 1 Door Models (HE.48504) 04891 (1) 2 Door Models (HE.485058) 04892 (1) Door Models (HE.485059) 0489 (1) 4 Door Models (HE.48500) 04894 (1) 5 Door Models (HE.48501) I. Drain an Heater (9) Electric & KoolGas 048908 (1) 1 Door Models (HE.48504) 080 (1) 2 Door Models (HE.485029) 080 (1) Door Models (HE.4850240) 0808 (1) 4 Door Models (HE.4850241) 0809 (1) 5 Door Models (HE.4850242) LAMS AND ALLASTS J. 04029 1 Lamp allast (A.448041) 0400 2 Lamp allast (A.448042) 045419 Lamp allast (A.448001) 042449 Export allast (A.042449) K. Standard Fluorescent Lamp eplace with like fixtures NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. lease have your model and serial number available. efer to INNOVATO EACH-IN GLASS DOO INSTALLATION AND SEVICE manual, /N 04258, for Innovator II door and frame replacement parts. /N 042544_M

Engineering 01-200 lan Views each In 2,, each-in 4, & 5 Door L-M-MF Dimensions shown as in. & (mm). 1, 2,, 4 & 5 Door lan View A C D 41 9 /1 (105) Skid/External ase Waste Outlet Electrical Wireway 48 (1219) (152) ottom Frt. Support efrig. Outlet 5 /8 (142) 2 (81) 4 5 /8 (89) 9 /8 (999) 41 5 /8 (105) 4 /4 (1110) 4 (102) () Front Water Seal (see note **) elay & Terminal lock Location 4 (102) () (see note *) 1 Dr 2 Dr Dr 4 Dr 5 Dr General (A) Case Length (without ends or partitions) 1 1 /2 (800) 2 (155) 92 1 /2 (250) 122 /8 (121) 15 /8 (89) Maximum O/S dimension of case back to front 4 /4 (1111) 4 /4 (1111) 4 /4 (1111) 4 /4 (1111) 4 /4 (1111) (Includes bumper) ack of case to rear of splashguard 9 /8 (1000) 9 /8 (1000) 9 /8 (1000) 9 /8 (1000) 9 /8 (1000) Width of Skidrail 4 1 /2 (114) 4 1 /2 (114) 4 1 /2 (114) 4 1 /2 (114) 4 1 /2 (114) Width of ottom Front Support (152) (152) (152) (152) (152) Stub-up area between front skidrail and splashguard /8 (12) /8 (12) /8 (12) /8 (12) /8 (12) Electrical Service H end of case to the center of nearest knockout 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) () H end of case to the center of LH knockout 2 1 /2 (98) 58 (14) 88 1 /2 (2248) 118 /8 (019) 149 /8 (94) ack O/S of case to center of knockout 41 5 /8 (1058) 41 5 /8 (1058) 41 5 /8 (1058) 41 5 /8 (1058) 41 5 /8 (1058) * NOTE: Electrical Field Wiring Connection oint is at terminal. Waste Outlet (C) ight end of case to center of waste outlet 15 /4 (400) 2 /4 (0) 54 1 /4 (18) 4 1 /4 (115) 5 /8 (194) ack O/S of case to center of waste outlet 4 5 /8 (89) 4 5 /8 (89) 4 5 /8 (89) 4 5 /8 (89) 4 5 /8 (89) Water Seal Edge of water seal to center of waste outlet 11 (29) 11 (29) 11 (29) 11 (29) 11 (29) Outside diameter of drip piping 1 1 /4 (2) 1 1 /4 (2) 1 1 /4 (2) 1 1 /4 (2) 1 1 /4 (2) ** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case efrigeration Outlet H end of case to center of H refrigeration outlet 5 /8 (1) 5 /8 (1) 5 /8 (1) 5 /8 (1) 5 /8 (1) ack O/S of case to center of refrigeration outlet 2 (81) 2 (81) 2 (81) 2 (81) 2 (81) (D) Outside bottom front supports from end of case /4 (10) /4 (10) /4 (10) /4 (10) /4 (10) Center bottom front support from Centerline NA 24 (10) 24 (10) 24 (10) 24 (10) Distance between Center and Outside supports will vary 2 of HUSSMANN COOATION, ridgeton, MO 044-248 U.S.A. L with Innovator Doors Technical Data Sheet

each-in 2,, 4 and 5 Door Models Dimensions shown as in. & (mm). Impact L With INNOVATO Doors Frozen Food & Ice Cream EFIGEATION DATA L/M/MF 82 /8 (2091) 2 (52) (100) Frame 2 1 /2 (1588) 40 /4 (105) 8 1 /2 (2120) Note: This data is based on store temperature and humidity that does not exceed 5 F and 55%.H. 2,, 4, 5 Door 1 Door FF IC FF IC Discharge Air ( F) 5 12 2 5 Evaporator ( F) 11 19 11 19 Unit Sizing ( F) 14 22 14 22 tu/hr/door* arallel 100 10 190 140 Conventional 125 1400 1420 1590 *Optional LED lighting reduces refrigeration load by 100 tu/hr/door. DEFOST DATA ALL FF IC Frequency (hr) 24 24 Defrost Water (lb/dr/day) 1.2 1.2 (± 15% based on case configuration and product loading.) 22 Shelf (559) ELECTIC FF IC Temp Term ( F) 48 48 Failsafe (minutes) 45 45 GAS Duration (minutes) 20 20 5 1 /2 (140) Electrical Field Wiring Connection is at Terminal /8 (9) 1 1 /2 (8) 2 5 /8 (02) efrigeration Outlet Fan Electrical Stub-up Area 2 (81) 4 5 /8 (89) 9 /8 (999) 41 5 /8 (105) 4 /4 (1110) NSF Certification These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ) Standard # requirements. 4 /4 (121) 2 5 /8 () OFFTIME Not ecommended CONVENTIONAL CONTOLS Low ressure ackup Control FF IC CI/CO (Temp F)** 18 / 4 2 / 45 Indoor Unit Only, ressure Defrost Termination (Temp F)** Not ecommended **Use a Temperature ressure Chart to determine SIG conversions. HSICAL DATA Drip ipe (in.) 1 1 /4 Liquid Line (in.) /8 Suction Line (in.) /8 Estimated Charge (lb)*** 1Dr 0.9 4Dr. 2Dr 1.8 5Dr 4. Dr 2. ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. Length Added to Lineup by each Standard End (in.) 2 Optional End with Window (in.) 1 1 /2 Optional artition (in.) 1 1 /2 /N 042544_M HUSSMANN COOATION IDGETON, MO 044-248 U.S.A. WWW.HUSSMANN.COM of

Impact L With INNOVATO Doors Frozen Food & Ice Cream Hussmann recommends against frame heater cycling with Innovator doors to prevent door seals from freezing to the frames and tearing. Electrical Data Number of Fans 12W 1 2 4 5 Amperes Watts Merchandiser 1Dr 2Dr Dr 4Dr 5Dr 1Dr 2Dr Dr 4Dr 5Dr Evaporator Fan 120V 0Hz Standard 0.5 1.0 1.95 2.0.25 50 100 150 200 250 120V 50Hz Standard 0.5 1.50 2.25.00.5 5 114 11 228 285 220V 0Hz Export NA 0. 0.99 1.2 1.5 NA 100 150 200 250 220V 50Hz Export NA 0. 1.14 1.52 1.90 NA 114 11 228 285 120V 0Hz Energy Efficient 0.0 0.0 0.90 1.20 1.50 18 54 2 90 220V 0Hz Energy Efficient NA 0.0 0.45 0.0 0.5 NA 54 2 90 Door Anti-sweat Heaters (on fan circuit) 120V 50/0Hz Standard 0. 1.54 2.1.08.8 92 185 28 0 4 220V 50/0Hz Export NA 0.84 1.2 1.8 2.10 NA 185 28 0 4 Frame Anti-sweat Heaters (on fan circuit) 120V 50/0Hz Standard 0.9 0.8 1.18 1.5 1.9 4 94 141 188 2 220V 50/0Hz Export NA 0.4 0.4 0.85 1.0 NA 94 141 188 2 Minimum Circuit Ampacity 120V 0Hz Standard.01.82 5.4.45 9.28 120V 50Hz Standard.01 4.02 5.94.85 9.8 220V 0Hz Export NA 2.1.09 4.05 5.02 220V 50Hz Export NA 2.2.24 4.25 5.2 120V 0Hz Energy Efficient NA.12 4.59.05.5 220V 0Hz Energy Efficient NA 1. 2.55. 4.12 Maximum Over Current rotection 120V 20 20 20 20 20 Maximum Over Current rotection 220V 15 15 15 15 15 Defrost Drain Heaters 1. 0. 1.25 2.00 2.5 200 5 150 240 00 (Export: 220V 50 hz) NA 0.4 0. 1.22 1.5 NA 84 18 29 208V Electric Defrost 2.88.2 10.08 1.4 1.82 00 1400 2100 2800 500 (Export: 220V 50 hz) NA.11 10. 14.24 1.9 NA 154 245 1 914 Standard Vertical Lighting 1Dr 2Dr Dr 4Dr 5Dr 1Dr 2Dr Dr 4Dr 5Dr Innovator* Doors 1.00 1.50 2.00 2.50.00 120 180 240 00 0 (Export: 220V 50 hz) NA 0.84 1.12 1.40 1.8 NA 185 24 08 0 Optional LED Lighting Gelcor 0.58 0.8 1.1 1.45 1.4 0 105 140 14 209 Optional LED Lighting Hussmann Always*right 0.41 0. 0.1 1. 1.55 50 89 140 14 18 * Innovator or Innovator II 4 of HUSSMANN COOATION, ridgeton, MO 044-248 U.S.A. L with Innovator Doors Technical Data Sheet

Fan and Heater Circuits - Electric Defrost (standard) Low Temperature CICLED NUMES = ATS LIST ITEM NUMES = ed = urple 2 = urple (2 ands) D = Dark lue = lack =rown =ellow O = Orange W = White THESE AE MAKE COLOS (WIE MA VA.) 208V 1 2 ear Defrost Heater Front Defrost Heater 8 8 Evaporator Fan elay 1 C 8 Defrost Limit 4 O.O.. 208V 4 5 CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the individual merchandiser s defrost circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240. 120V OWE 120V OWE 14 1 1 COM Fan elay F N.C. Fan elay F N.O. A.S. elay A.S. COM N.C. Switch 1 O L O 20 Defrost Termination FIELD WIED Thermostat 2 D D C.O.. elay Control NEUTAL 10 11 12 Evaporator Fans 1 5 od Heater (Drain) 9 2 A.S. elay 1 c N.C. Frame A.S. Heaters Door A.S. Heaters Terminal locks in aceway Low Temperature with Electric Defrost 2 O O 2 W C.O.. 1 2 4 5 8 10 11 12 1 14 1 1 W 2 25 24 22 20 21 22 24 25 2 NEUTAL 2 21 efer to Innovator each-in Glass Door, Installation and Service manual, /N 04258, for Innovator door and frame replacement parts. Defrost Termination 2 Thermostat efrigeration Thermostat (Optional) ink Dark lue } To Condensing Unit ermanent Internal DEFOST HEATES (208V) emovable External FANS & A.S. (Neutral) FANS & A.S. (Neutral) Electric Defrost Sequence - Low Temperature 1. ower from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan elay (). elay Contacts open the fan circuit and energizes the Drain an Heater. 2. If the Defrost Heater raises internal air temperature above 90 F, the Defrost Limit Thermostat (4) will open.. Temperature rise of the evaporator closes the elay Control Thermostat (5) at about 5 F, energizing 120V A.S. elay (). This relay s contacts open the Frame and Door Heater Circuits. 4. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator Fan elay Circuits. The Drain an Heater goes off and fans are on. 5. Temperature fall of the evaporator opens the elay Control Thermostat (5) at about 20 F, de-energizing 120V A.S. elay (). A.S. elay Contacts close the Frame and Door Heater Circuits. /N 042544_M HUSSMANN COOATION IDGETON, MO 044-248 U.S.A. WWW.HUSSMANN.COM 5 of

Fan and Heater Circuits - Gas Defrost (optional) Low Temperature CICLED NUMES = ATS LIST ITEM NUMES = ed = urple 2 = urple (2 ands) D = Dark lue = lack =rown =ellow O = Orange W = White THESE AE MAKE COLOS (WIE MA VA.) 120V OWE 14 1 1 COM Fan elay F N.C. Fan elay F N.O. A.S. elay A.S. COM N.C. Defrost Limit 4 elay Control O.O.. 10 12 Evaporator Fans 1 5 C.O.. 11 od Heater (Drain) 9 2 A.S. elay 1 c c Fan elay Frame A.S. Heaters Door A.S. Heaters W 2 NEUTAL 2 25 24 22 21 efer to Innovator each-in Glass Door, Installation and Service manual, /N 04258, for Innovator door and frame replacement parts. 120V OWE NEUTAL Switch 1 O L O 20 efrigeration Thermostat (Optional) Low Temperature with Gas Defrost Terminal locks in aceway 2 O O 2 W ink }To Condensing Unit 10 11 12 1 14 1 1 20 21 22 24 25 2 emovable External FANS & A.S. (Neutral) ermanent Internal FANS & A.S. (Neutral) Gas Defrost Sequence - Low Temperature 1. Defrost vapor enters evaporator causing a rise in temperature. At about 5 F the Control elay Thermostat (5) closes the Fan elay () and Control elay () circuit. The opens the Fan, Door Heater, and Frame Heater circuits, while energizing the Drain an Heater (9). 2. If the Drain an Heater (9) raises internal air temperature above 90 F, the Heater Limit Thermostat (4) will open.. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20 F, the Control elay Thermostat will open, de-energizing the Control elay and Fan elay (). Control and Fan elay s will open the Drain an Heater circuits, and will close the Fan, Door Heater, and Frame Heater circuits. of HUSSMANN COOATION, ridgeton, MO 044-248 U.S.A. L with Innovator Doors Technical Data Sheet