Certificate of Conformity

Similar documents
Certificate of Conformity

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Flameproof Manual Call Points Series MCP

IECEx Certificate of Conformity

UL HAZARDOUS LOCATIONS SERVICES

manual addendum DELPHI Ex

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Operating Instructions

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

TYPE APPROVAL CERTIFICATE

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

INSTRUCTION MANUAL (ATEX / IECEx)

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Explosion-proof Immersion Heater Type D-8660

Certification Supplement Manual

ATM Lighting sp. z o.o

Illumination unit For sight glass level indicator Model LGI

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

OPTIBAR DP 7060 Supplementary Instructions

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Manual Power relay SR853

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

DTS Light fittings for explosive atmospheres

OPTIWAVE X500 Supplementary Instructions

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

Flameproof Manual Call Points

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

Flameproof Manual Call Points Series MCP

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

User s Manual YTA610 and YTA710 NEPSI Certification

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Inductive slot sensor

Integrated Solutions Low Voltage Systems

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

TRASCO ATEX Couplings

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

Guide for hazardous areas

IECEx Certificate of Conformity

ATM Lighting sp. z o.o

Safety instructions VEGAPULS 64

ANNEX GD-CERT-EX-EN SIT

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

IECEx Certificate of Conformity

Rosemount 644 Temperature Transmitter

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Rosemount 248 Temperature Transmitter

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

INSTRUCTION & SERVICE MANUAL

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Survey of electrical equipment installed in hazardous areas on tankers

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Indoor/outdoor resistance thermometer Model TR60

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Electrical Installations Design, Selection, Erection and Inspection

Certificate of Compliance

Explosion Proof Manual Call Points Series MCP

Hazardous Area Portable Fan Heater The Bulldog

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

Rosemount 848T High Density Temperature Measurement Family

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Certificate of Compliance

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

Explosion Proof Combination Signal db (A) / 5 Joule

Drive systems for the chemical, oil and gas industry. Electric drives and systems

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

ELECTRICAL EX EQUIPMENT

XLFE-4/1. Borosilicate glass globe

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Rosemount 3144P Temperature Transmitters with FOUNDATION Fieldbus Protocol. Quick Start Guide , Rev DA June 2016

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Rosemount 3144P Temperature Transmitter

Dräger Polytron 5700 IR Detection of flammable gases and vapours

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Transcription:

AWARDED TO APPLICANT SCHLEMMER GROUP EINSTEINRING 10 85609 ASCHHEIM DEUTSCHLAND MANUFACTURER: S.I.B (SCHLEMMER INDUSTRY AND BUILDING PARTS) 25 RUE THÉOPHILE SOMBORN 57220 BOULAY FRANCE Bureau Veritas Certification certify that the product constant at scope of supply below specified, has been assessed and find in accordance with requirements of documents of reference. Documents of Reference ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-7:2008, ABNT NBR IEC 60079-31:2014 and ABNT NBR IEC 60529:2017 CERTIFICATE ISSUED BASED ON THE MANUFACTURER EVALUATION OF QUALITY MANAGEMENT SYSTEM AND PRODUCT TESTS MODEL, ACCORDING TO CLAUSE 6.1 OF THE CONFORMITY EVALUATION RULE, ATTACHED TO THE ORDINANCE N 179 FROM INMETRO,ISSUED IN MAY 18 TH 2010. CABLE GLAND TYPE ECx MODELS: CM, ECEA CM, CM M1, ECEA M1, ECEA M2, GSE and ECEA GSE MARKING: Ex eb IIC Gb IP66/IP68 (5 bar) Ex tb IIIC Db IP66/IP68 (5 bar) Initial date of this cycle: MARCH 22 TH 2017. Certificate valid until: MARCH 21 ST 2020. This Certificate of Conformity was issued according to the certification model 5 and is valid only accompanied by pages 1 to 7. The validity of this Certificate is linked to carrying out assessments maintenance and treatment of possible non-conformity in accordance with the Bureau Veritas Certification guidelines and in the specific Inmetro Ordinances (RAC). To check the updated condition of regularity of this Certificate must be obtained from the product database and Certificate Services on Inmetro site. Product Certification Contract: BR.2719935. Certificate Number: BR230665-X. Número do Certificado INMETRO: Original approval Date: JUNE 13 RD 2011. Vagner Valentino Coordenador Técnico de Certificação de Produto Bureau Veritas Certification Avenida Alfredo Egídio de Souza Aranha, 100, Torre C, 3º andar Centro Administrativo Santo Amaro 04726-170, Chácara Santo Antônio, São Paulo, SP, Brasil www.bureauveritascertification.com.br 1712201114001 1 tel.: 112655-9000 / fax: 112655-9322 Page 1 of 7 O uso da Identificação acima indica a acreditação com Relação às atividades cobertas pelo Certificado nº OCP-0018.

SPECIFICATION: The Cable glands are used for the entry of cables in electrical equipment (Boxes, light fixtures, outlets, etc...) or metallic plastics, ensuring the tightness between the cable and the electrical equipment. The cable glands can use in zones 1 and 2 for gas group IIA, IIB, IIC and for zones 21 and 22 for group IIIC for combustible dusts or not combustible. The cable glands can be manufactured with metric thread, NPT or PG and were approved with a degree of protection IP66/IP68 (5 bar). TECHNICAL DOCUMENTATION: Certificate of Conformity LCIE 01ATEX6006X/03 of 2008/11/14; Certificate of Conformity LCIE 01ATEX6006X/04 of 2015/05/06; Certificate of Conformity n IECEx LCIE 16.0014X de 2016/06/03; Test Report LCIE n 60000011-1 of 2003/05/21; Test Report LCIE n 60055106-555530/05 of 2007/08/31; Test Report LCIE n 85867-576728 of 2008/11/14; Test Report LCIE n 133536-668141-08 of 2015/05/06; Test Report LCIE n FR/LCIE/ExTR16.0021/00 de 2016/06/03; Technical Dossier n TR/011/01 of 2011/02/30; Analysis Report (RA) n 005/2011 of 2011/05/12; Analysis Report (RA) n 001/2014 of 2014/06/16; Analysis Report (RA) n 001/2017 of 2017/03/16; Factory Inspection performed in 2017/03/08; Manual in Portuguese. 1712201114002 2 Page 2 of 7

Drawing Description Revision Date C 1900 000 P-E Atex NPT Modèle Ex e CM C 1900 000 KV Atex NPT Model Ex e CM C 1900 000 C-G Atex NPT Model Ex e CM C 2000 008 P-E Atex PG & ISO Modèle Ex e CM I 2010/09/28 C 2000 008 KV Atex PG & ISO Model Ex e CM I 2010/09/28 C 2000 008 C-G Atex PG & ISO Model Ex e CM I 2010/09/28 C 2100 000 P-E Atex PG LANG Modèle Ex e CM C 2100 000 KV Atex PG LANG Model Ex e CM C 2100 000 C-G Atex PG LANG Model Ex e CM C 2200 002 Presse-Etoupe Atex Modèle Ex e GSE PG COURT C 2200 002 Kabelverschraubung Atex Model Ex e GSE PG KURZ C 2200 002 Cable-Glands Atex Model Ex e GSE PG SHORT C 2300 009 Presse-Etoupe Atex Modèle Ex e GSE PG C 2300 009 Kabelverschraubung Atex Model Ex e GSE PG LANG C 2300 009 Cable-Glands Atex Model Ex e GSE PG LANG C 2400 000 Presse-Etoupe Atex Modèle Ex e GSE Métrique Court D 2007/02/12 C 2400 000 Kabelverschraubung Atex Model Ex e GSE Metrisch Kurz D 2007/02/12 C 2400 000 Cable-Glands Atex Model Ex e GSE Metric Short D 2007/02/12 C 2500 000 Presse-Etoupe Atex Modèle Ex e GSE Metrique Long C 2500 000 Kabelverschraubung Atex Model Ex e GSE Metrisch Lang C 2500 000 Cable-Glands Atex Model Ex e GSE Metric Long C 2600 000 Presse-Etoupe Atex Modèle Ex e GSE NPT C 2600 000 Kabelverchraubung Atex Model Ex e GSE NPT C 2600 000 Cable-Glands Atex Model Ex e GSE NPT C 2600 800 Presse-Etoupe Atex Modèle Ex e GSE GAZ COURT C 2600 800 Kabelverchraubung Atex Model Ex e GSE GAZ KURZ C 2600 800 Cable-Glands Atex Model Ex e GSE GAZ SHORT 1712201114003 3 Page 3 of 7

C 2700 000 Presse-Etoupe Atex Modèle Ex e GSE GAZ C 2700 000 Kabelverchraubung Atex Model Ex e GSE GAZ LANG C 2700 000 Cable-Glands Atex Model Ex e GSE GAZ C 3200 001 Presse-Etoupe Atex Modèle Ex e ECEA GSE PG COURT Kabelverchraubung Atex Model Ex e ECEA GSE PG C 3200 001 KURZ C 3200 001 Cable-Glands Atex Model Ex e ECEA GSE PG SHORT C 3200 200 Presse-Etoupe Atex Modèle Ex e ECEA GSE À PAVILLON PG COURT Kabelverchraubung Atex Model Ex e ECEA GSE MIT C 3200 200 BIEGESCHUTZ PG KURZ C 3200 200 Cable-Glands Atex Model Ex e ECEA GSE WITH BEND PREVENTION PG SHORT C 3300 008 Presse-Etoupe Atex Modèle Ex e ECEA GSE PG Kabelverchraubung Atex Model Ex e ECEA GSE PG C 3300 008 LANG C 3300 008 Cable-Glands Atex Model Ex e ECEA GSE PG C 3300 200 Presse-Etoupe Atex Modèle Ex e ECEA GSE À PAVILLON PG Kabelverchraubung Atex Model Ex e ECEA GSE MIT C 3300 200 BIEGESCHUTZ PG LANG Cable-Glands Atex Model Ex e ECEA GSE With Bend C 3300 200 Prevention PG C 3400 000 Presse-Etoupe Atex Modèle Ex e ECEA GSE MÉTRIQUE COURT C 3400 000 Kabelverchraubung Atex Model Ex e ECEA GSE METRISCH KURZ Cable-Glands Atex Model Ex e ECEA GSE METRIC C 3400 000 SHORT C 3500 000 Presse-Etoupe Atex Modèle Ex e ECEA GSE MÉTRIQUE 1712201114004 4 Page 4 of 7

C 3500 000 Kabelverchrabung Atex Model Ex e ECEA GSE METRISCH LANG Cable-Glands Atex Model Ex e ECEA GSE METRIC C 3500 000 C 3600 000 Presse-Etoupe Atex Modèle Ex e ECEA GSE NPT C 3600 000 Kabelverchrabung Atex Model Ex e ECEA GSE NPT C 3600 000 Cable-Glands Atex Model Ex e ECEA GSE NPT C 3600 800 Presse-Etoupe Atex Modèle Ex e ECEA GAZ COURT Kabelverchrabung Atex Model Ex e ECEA GSE GAZ C 3600 800 KURZ C 3600 800 Cable-Glands Atex Model Ex e ECEA GSE SHORT C 3700 000 Presse-Etoupe Atex Modèle Ex e ECEA GSE GAZ Kabelverchrabung Atex Model Ex e ECEA GSE GAZ C 3700 000 LANG C 3700 000 Cable-Glands Atex Model Ex e ECEA GSE GAZ C 3800 000 Presse-Etoupe Atex Model Ex e ECEA CM D 2008/09/17 C 3800 000 Kv Atex Model Ex e ECEA CM D 2008/09/17 C 3800 000 Cable-Glands Atex Model Ex e ECEA CM D 2008/09/17 C 7000 003 P-E Atex PG Modèle Ex e ECEA M1 G 2008/09/17 C 7000 003 KV Atex PG Model Ex e ECEA M1 G 2008/09/17 C 7000 003 C-G Atex PG Model Ex e ECEA M1 G 2008/09/17 C 7000 100 P-E Atex PG Modèle Ex e CM M1 G 2008/09/17 C 7000 100 KV Atex PG Model Ex e CM M1 G 2008/09/17 C 7000 100 C-G Atex PG Model Ex e CM M1 G 2008/09/17 C 7100 200 P-E Atex Metrique Modèle Ex e CM M1 D 2008/09/17 C 7100 200 KV Atex Metrisch Model Ex e CM M1 D 2008/09/17 C 7100 200 C-G Atex Metric Model Ex e CM M1 D 2008/09/17 C 7100 300 P-E Atex Metrique Modèle Ex e ECEA M1 D 2008/09/17 C 7100 300 KV Atex Metrisch Model Ex e ECEA M1 D 2008/09/17 C 7100 300 C-G Atex Metric Model Ex e ECEA M1 D 2008/09/17 C 7200 007 P-E Atex Pg Modèle Ex e ECEA M2 E 2008/09/17 1712201114005 5 Page 5 of 7

C 7200 007 KV Atex PG Model Ex e ECEA M2 E 2008/09/17 C 7200 007 C-G Atex PG Model Ex e ECEA M2 E 2008/09/17 C 7300 200 P-E Atex Metrique Modèle Ex e ECEA M2 D 2008/09/17 C 7300 200 KV Atex Metrisch Model Ex e ECEA M2 D 2008/09/17 C 7300 200 C-G Atex Metric Model Ex e ECEA M2 D 2008/09/17 C 7500 008 P-E Atex PG Modèle Ex e ZA M1 F 2008/09/17 C 7500 008 KV Atex PG Model Ex e ZA M1 F 2008/09/17 C 7500 008 C-G Atex PG Model Ex e ZA M1 F 2008/09/17 C 7600 120 P-E Atex NPT Modèle Ex e CM M1 C 2008/09/17 C 7600 120 KV Atex NPT Model Ex e CM M1 C 2008/09/17 C 7600 120 C-G Atex NPT Model Ex e CM M1 C 2008/09/17 C 7600 130 P-E Atex NPT Modèle Ex e ECEA M1 C 2008/09/17 C 7600 130 KV Atex NPT Model Ex e ECEA M1 C 2008/09/17 C 7600 130 C-G Atex NPT Model Ex e ECEA M1 C 2008/09/17 C 7700 000 P-E Atex NPT Modèle Ex e ECEA M2 C 2008/09/17 C 7700 000 KV Atex NPT Model Ex e ECEA M2 C 2008/09/17 C 7700 000 C-G Atex NPT Model Ex e ECEA M2 C 2008/09/17 C 8000 100 P-E Atex PG Modèle Ex e ZV M1 E 2008/09/17 C 8000 100 KV Atex PG Model Ex e ZV M1 E 2008/09/17 C 8000 100 C-G Atex PG Model Ex e ZV M1 E 2008/09/17 C7442XXX Presse Etoupe CM /WADI-TEC ECEA METAL - Modèle : Ex e / tb ISO A 2016/04/22 OBSERVATIONS: 1. The letter X after the Certificate number means the following special conditions for safe use: For models CM, CM M1 e GSE the user must ensure proper locking of the cable near the cable entry. Using ambient temperature range: -20 C Ta +80 C -40 C Ta +100 C (NEOPREN) 1712201114006 6 Page 6 of 7

2. This Certificate is valid only for products with the same model and type as the tested prototype. Any modification in the project, as well as the use of components apart from those defined by the technical documentation, without previous authorization from Bureau Veritas Certification, will invalid this Certificate. 3. The cable glads shall be marked on the external surface and in a visible place, the conformity mark and the technical characteristics according to the specifications from standards ABNT NBR IEC 60079-0 / ABNT NBR IEC 60079-7 / ABNT NBR IEC 60529 and the conformity assessment requiremnts, attached to INMETRO Ordince n 179, published in May 18 th 2010. This marking must be readable and durable, taking into consideration possible chemical corrosion. 4. The equipment must be installed in compliance with the relevant standards in electrical installations in explosive atmospheres and the manufacturer's recommendations 5. The activities of installation, inspection, maintenance, repair, overhaul and recovery of equipment are the responsibility of users and must be implemented in accordance with the requirements of current technical standards and the manufacturer's recommendations. 6. The Manufacturer shall provide manual of installation and safe use written in Portuguese. REVISIONS HISTORY DATE DESCRIPTION 2011/06/13 Initial Issue 2014/06/17 Revision 1 Recertification 2017/03/20 Revision 2 - Recertification 2017/12/20 Revision 3 - Inclusion of the certificate of conformity IECEx LCIE 16.0014X 1712201114007 7 Page 7 of 7