Product Data. 58VLR LOW --- BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES VLR FEATURES/BENEFITS

Similar documents
Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Product Data 58VMR FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data 369AAN FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. S UTEC ignition control and fan timer board provide. S S Cabinet features an insulated enclosure for the burner

Product Data. S Unit may also be sidewall vented with an approved A S OVM units equipped with ECM 2.3 Variable Speed

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 367AAN Low --- Boy Oil Furnace Input Capacities: 70,000 thru 154,000 BTUH Series E 367AAN FEATURES/BENEFITS

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data STANDARD FEATURES

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58CVA/CVX INFINITY 80 VARIABLE SPEED 4---WAY MULTIPOISE GAS FURNACE Input Capacities: 70,000 thru 155,000 Btuh Series 160

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Wt. Lbs Model Number (BTUH) Hz

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

TSTAT0201CW Recommended (sold separately)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. Comfort Heatt technology, the ultimate in heating comfort...

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Cooling Capacity CFM range

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Product Data. IdealComfortt technology, the ultimate in heating comfort...

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TSTAT0101SC Recommended (order separately)

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

395CAV Sizes 045 thru 155 Series H and J

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

TECHNICAL SPECIFICATIONS

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

MERIT SERIES Downflow

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Product Data. 59TN6A InfinityR Two---Stage, Variable Speed Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 59MN7A Infinityr Modulating Way Multipoise Condensing Gas Furnace Series 100

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

ELITE SERIES Downflow - High Efficiency Blower Motor

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

PREMIUM OIL Furnaces. Variable Speed Option. Up to 87.5% Efficiency Optional Cooling Up to 4 Tons High-Grade Stainless Steel Heat Exchanger FEATURING

TECHNICAL SPECIFICATIONS

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Product Data. ERVCCLHA Energy Recovery Ventilators

T9MPV SmartComfort VS90 Product Specifications

TECHNICAL SPECIFICATIONS

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. Infinity 96 Model 58MVB Deluxe 4-Way Multipoise Variable-Speed Condensing Gas Furnace. Series 100 Input Rates: 40,000 thru 120,000 Btuh

355MAV Sizes 040 thru 120 Series E

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

8+* Bulletin No November 1997

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Transcription:

LOW --- BOY OIL FURNACE INPUT RATE: 70,000 thru 154,000 BTUH ERIE 110 Product Data THE LATET IN OIL FURNACE TECHNOLOGY A06626 The model combines variable -speed high efficiency and quiet operation with oil heating technology. The is available in 2 sizes. Each size can be fired at 3 different rates by a simple nozzle and pump pressure change. Unit 105 covers input ranges from 70,000 to 105,000 Btuh. Unit 120 covers input ranges from 119,000 to 154,000 Btuh. The furnace design is a low -boy style for upflow applications, where overhead space is limited. The components of the are the finest in the industry. The unit uses a Riello oil burner with an electronic air damper. The is a standard part of a quality -built home. This high - efficiency furnace will provide years of quality service to home builders and homeowners alike. As with other Carrier furnaces, this model is designed to work as part of a total home comfort system which includes elements for cooling, air cleaning, humidification, ventilation, and zoning. This unit is not approved for use in mobile home installations. FEATURE/BENEFIT Riello Oil Burner High quality Riello oil burner allows safe and efficient combustion of oil. Casing Made of 18 gauge painted steel for years of durability. Cabinet features an insulated enclosure for the burner and controls. Insulation and oundproofing Unique sound trap along with insulated walls efficiently captures most combustion noise and vibrations and makes this unit one of the quietest on the market. Flue silence baffle ensures quiet operation. Combustion Products Venting Rear flue outlet. Unit may be vented using Type L vent material and a factory -built metal or masonry chimney. Unit may also be sidewall vented with an approved power venter. Variable peed Blower Variable speed blower for precise airflow selection of heating or cooling operation. Ignition Control and Electronic Fan Control Ignition control and fan control board provide reliable operation and easy connection of thermostat and accessory wiring. Combustion Chamber/Heat Exchanger Certifications Composed mainly of stainless and aluminized steel, the unique combination combustion chamber/heat exchanger resists corrosion, overheating, and deterioration. Heat transfer properties make it highly efficient. All seams are tightly welded for leak -free operation. unit is CA certified. The efficiency is AHRI efficiency rating certified. 1

W1 W2 HEAT COOL A A ON OFF B ON OFF B OFF ON C OFF ON C ON ON D ON ON D ON ON W1 W2 OFF OFF W3 W4 ADJ DELAY A A ON OFF B ON OFF B OFF ON C OFF ON C ON ON D ON ON D ON ON OFF W3 OFF P1 R14 LED7 GRN JW5 R2 W4 JW7 R12 D17 D18 D19 R1 D6 D7 D8 D9 D10 D11 D12 D14 JW6 JW3 JW4 120 VAC D20 JW1 LED4 LED3 LED5 LED7 LED8 LED1 R3 C2 U2 R23 R13 LED RED D21 D1 D3 D15 D16 JW2 01 D13 D02 D04 U1 C1 R22 KJ P3 C 120 VAC NEUTRAL HUM P2 24 VAC 1 2 OFF OFF 1 2 OFF OFF F1 1 2 OFF OFF 1 2 OFF OFF GRN R21 R20 GRN GRN GRN MO V1 GRN GRN HC 1 1168-83-1 Y Y/Y2 G DH O W R C NOTE 1. The Red LED to the right of P-1 will illuminate whenever the limit switch is open. 2. The Green LED below the left end of P-1 will flash when the blower motor is operating. The LED will flash one time for each 100 RPM. 3. The Green LEDs above Y1, Y/Y2, G, O, and W will illuminate whenever there is a 24V input from the thermostat. 4. The Green LED above DH will illuminate whenever there is not a 24VAC input applied. A96369 COMBUTION CHAMBER/ HEAT EXCHANGER CONTROL CENTER A96370 OIL BURNER A06115 MODEL NUMBER NOMENCLATURE 105 120 12 Variable peed Riello Burner Low --- Boy Oil Furnace Cooling ize Airflow (Nominal 400 CFM per 12,000 Btuh Cooling) 12 --- 1200 CFM Input Capacity 105 --- 70,000 Btuh with 0.40 gph nozzle 91,000 Btuh with 0.50 gph nozzle 105,000 Btuh with 0.65 gph nozzle 120 --- 119,000 Btuh with 0.75 gph nozzle 140,000 Btuh with 0.85 gph nozzle 154,000 Btuh with 1.00 gph nozzle eries Always Ask For C U Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org. 2

UNUED 3 1 2 3 4 5 H UM LEAD 2 6 7 E CON C H AC OO EA T L T N X C ON 1 2 5 6 8 7 9 10 4 3 11 G W R Y C 2 1 13 12 A06109 1. Variable -speed blower circulates air across the heat exchanger to transfer heat into the home. 2. Access door to air filters and blower. 3. Air filters. 4. Unique silencer system controls combustion noise. 5. Return -air plenum. 6. tainless steel combustion chamber. 7. Heat exchanger designed and shaped to efficiently transfer heat from furnace into the home. 8. upply -air plenum. 9. Fully insulated internal walls to minimize heat loss. 10. High limit control to prevent overtemperature. 11. Adjustable electronic fan control (inside) has low voltage electrical terminal strip for easy connection of thermostat, cooling control, electronic air cleaner, and humidifier. 12. Aesthetic removable cover. Hides and protects burner and controls. 13. High -performance oil burner. 3

CLEARANCE TO COMBUTIBLE UNIT APPLICATION LOW --- BOY Furnace 1 IDE upply Plenum and Warm---Air Duct Within 6 Ft of Furnace 1 BACK ervice Clearance 19 Furnace Casing or Plenum 2 TOP Horizontal Warm---Air Duct Within 6 Ft of Furnace 2 BOTTOM* 0 FLUE PIPE Horizontally or Below Pipe 4 Vertically Above Pipe 9 FRONT 8 *Floor may be combustible. NOTE: Adequate service clearance should be provided over and above these dimensions as required. PHYICAL DATA UNIT IZE 105---12 120---20 INPUT (BTUH) 70,000 91,000 105,000 119,000 140,000 154,000 HEATING CAPACITY* 57,000 74,000 85,000 99,000 115,000 127,000 NOZZLE 0.40 --- 70A 0.50 --- 70W 0.65 --- 70W 0.75 --- 70B 0.85 --- 70W 1.00 --- 70W FIRING RATE (GPH){ 0.50 0.65 0.75 0.85 1.00 1.10 AFUE% 83.5 83.5 83.5 83.5 83.5 83.0 OIL PUMP TAGE/PREURE (PIG) 1/160 1/170 1/135 1/130 1/140 1/125 HEATING TEMP RIE _F 55---85 55---85 55---85 55---85 55---85 55---85 HIPPING WEIGHT (LB) 235 235 235 260 260 260 BURNER MODEL (3450 RPM) RIELLO 40 --- F3 RIELLO 40 --- F3 * Capacity and AFUE in accordance with U.. Government DOE test procedures. { For rating purposes only. haded cells are as factory shipped. RIELLO 40 --- F3 RIELLO 40 --- F5 RIELLO 40 --- F5 RIELLO 40 --- F5 4

PERFORMANCE DATA UNIT IZE 105---12 120---20 BLOWER WHEEL DIAMETER X WIDTH (In.) 10 x 8 12 x 10 FILTER IZE (In.) --- (Disposable) (2) 12 x 20 x 1 (2) 16 x 20 x 1 ELECTRICAL DATA UNIT IZE 105---12 120---20 UNIT VOLT --- HERTZ --- PHAE 115 --- 60 --- 1 115 --- 60 --- 1 OPERATING VOLTAGE RANGE (Min---Max)* 104 --- 132 104 --- 132 MAXIMUM UNIT AMP 12.2 15.7 MINIMUM WIRE IZE (AWG) 14 12 MAXIMUM WIRE LENGTH (Ft){ 26 26 MAXIMUM FUE IZE OR CKT BKR (Amps)} 15 20 TRANFORMER (24v) 40va 40va EXTERNAL CONTROL POWER AVAILABLE Heating 40va 40va Cooling 30va 30va AIR CONDITIONING RELAY tandard tandard * Permissible limits of the voltage range at which the unit will operate satisfactorily. { Length is as measured one way along wire path between unit and service panel for maximum 2% voltage drop. } Time---delay fuse type is recommended. 5

IZE 105 AIRFLOW DATA (CFM) W1 --- HEAT *A (1=OFF,2=OFF)*** *B (1 = ON, 2 = OFF)*** C (1=OFF,2=ON)** D(1=ON,2=ON) HEAT INPUT (UGPH) 0.75 0.65 0.50 OIL HEATING MODE 24 VAC INPUT (R) ON W ONLY 1252 1268 1260 1013 1415 1433 1424 1145 1064 1078 1071 861 1019 1047 1064 1019 1151 1183 1202 1151 866 890 904 866 826 854 854 854 933 965 965 965 702 726 726 726 AME VALUE A A DIP WITCH POITION CONTINUOU FAN 24 VAC INPUT (R) ON G ONLY (TON) 778 813 808 795 *A 3.0 856 894 889 875 (1=OFF,2=OFF)*** 700 732 727 716 658 678 674 674 *B 2.5 724 746 741 741 (1 = ON, 2 = OFF)*** 592 610 607 607 559 577 567 543 C 2.0 615 635 567 543 (1=OFF,2=ON)** 503 519 624 597 D(1=ON,2=ON)* 483 477 450 413 D(1=ON,2=ON)** 1.5 531 525 495 454 D (1 = ON, 2 = ON)*** 435 429 405 372 COOLING OR HEAT PUMP HEATING MODE---INGLE PEED OR 2---PEED HIGH 24 VAC INPUT (R) ON Y/Y2 AND O (FOR COOLING) Dip switch position (TON) 1030 1070 1075 1019 * 3.0 1133 1177 1183 1121 ** 927 963 968 917 868 886 890 894 * 2.5 955 975 979 983 B (1 = ON, 2 = OFF)*** 781 797 801 805 696 719 729 720 2.0 766 791 802 792 626 647 656 648 D(1=ON,2=ON)* 567 587 572 551 D(1=ON,2=ON)** 1.5 624 646 629 606 D (1 = ON, 2 = ON)*** 510 528 515 496 NOTE: In cooling---dehumidification mode, with no 24VAC input to DH, the CFM is reduced 15% 6

IZE 105 AIRFLOW DATA (CFM) (CONTINUED) * ** * B (1 = ON, 2 = OFF)*** D(1=ON,2=ON)* D(1=ON,2=ON)** D (1 = ON, 2 = ON)*** COOLING OR HEAT PUMP HEATING MODE---2---PEED LOW 24 VAC INPUT (R) ON Y1 AND O (FOR COOLING) (TON) 598 613 608 596 3.0 658 674 669 656 538 552 547 536 536 550 531 511 2.5 590 605 584 562 482 475 478 460 485 473 450 398 2.0 534 520 495 438 437 426 405 358 420 420 364 337 1.5 462 462 400 371 378 378 328 303 NOTE: In cooling---dehumidification mode, with no 24VAC input to DH, the CFM is reduced 15%. DELAY PROFILE FOR OIL HEATING MODE W4 --- DELAY HEAT INPUT (U GPH) PreRun On --- Delay CFM Level --- Time hortrun On --- Delay CFM Level --- Time Off --- Delay CFM Level --- Time** A(1=OFF,2=OFF) 0.75 13% --- 45 sec. 19% --- 30 sec 38% --- 3 min. B(1=ON,2=OFF) 0.65 13% --- 45 sec. 19% --- 60 sec 38% --- 3 min. C(1=OFF,2=ON) 0.5 13% --- 60 sec. 13% --- 60 sec 38% --- 3 min. D(1=ON,2=ON) All 13% --- 30 sec. 100% --- 0 sec 100% --- 2 min. DELAY PROFILE FOR COOLING OR HEAT PUMP HEATING MODE No adjustment PreRun On --- Delay hortrun On --- Delay Off --- Delay A/C size required CFM --- Level --- Time CFM Level --- Time CFM Level --- Time All 13% --- 30 sec. 75% --- 2.5 min. 50% --- 3 min. * CFM with W3---ADJ Dip witch A Position ** CFM with W3---ADJ Dip witch B Position. *** CFM with W3---ADJ Dip witch C Position. { PreRun is the time with 0 CFM after the call for cooling or heating. The hortrun come after the PreRun. } hortrun is the time before the blower starts at normal speed, with very low CFM to minimize cool draft in the air distribution system. {{ Off---delay is the time required to cool down the coil (heating mode) with low CFM to minimize cool draft in the air distribution system. 7

IZE 105 POWER DRAW (WATT) W1 --- HEAT HEAT INPUT (UGPH) OIL HEATING MODE 24 VAC INPUT (R) ON W ONLY POWER DRAW (WATT) A(1=OFF,2=OFF) 0.75 341 448 516 394 B(1=ON,2=OFF) 0.65 207 302 368 394 C(1=OFF,2=ON) 0.50 132 204 246 297 D(1=ON,2=ON) AME VALUE A A DIP WITCH POITION NOTE: W3---ADJ set in witch position A. (TON) CONTINUOU FAN 24 VAC INPUT (R) ON G ONLY POWER DRAW (WATT) A(1=OFF,2=OFF) 3.0 113 186 225 270 B(1=ON,2=OFF) 2.5 84 140 179 219 C(1=OFF,2=ON) 2.0 64 117 151 182 D(1=ON,2=ON) 1.5 53 96 128 169 NOTE: W3---ADJ set in witch position A. COOLING OR HEAT PUMP HEATING MODE---INGLE PEED OR 2---PEED HIGH 24 VAC INPUT (R) ON Y/Y2 AND O (FOR COOLING) (TON) POWER DRAW (WATT) A(1=OFF,2=OFF) 3.0 211 309 371 400 B(1=ON,2=OFF) 2.5 144 216 264 317 C(1=OFF,2=ON) 2.0 92 154 201 241 D(1=ON,2=ON) 1.5 65 116 153 187 NOTE: W3---ADJ set in witch position A. (TON) COOLING OR HEAT PUMP HEATING MODE---2---PEED LOW 24 VAC INPUT (R) ON Y1 AND O (FOR COOLING) POWER DRAW (WATT) A(1=OFF,2=OFF) 3.0 72 125 161 197 B(1=ON,2=OFF) 2.5 62 111 143 178 C(1=OFF,2=ON) 2.0 53 98 126 168 D(1=ON,2=ON) 1.5 45 89 124 150 NOTE: W3---ADJ set in witch position A. 8

IZE 120 AIRFLOW DATA (CFM) OIL HEATING MODE 24 VAC INPUT (R) ON W ONLY W1 --- HEAT * ** *B (1 = ON, 2 = OFF)*** C (1=OFF,2=ON)** D(1=ON,2=ON) * ** * B (1 = ON, 2 = OFF)*** D(1=ON,2=ON)* D(1=ON,2=ON)** D (1 = ON, 2 = ON)*** HEAT INPUT (UGPH) 0.85 1.00 1.10 (TON) 5.0 4.0 3.5 3.0 1388 1426 1426 1426 1568 1611 1611 1611 1180 1212 1212 1212 1682 1697 1674 1666 1901 1918 1892 1883 1430 1442 1423 1416 1839 1839 1839 1852 2078 2078 2078 2093 1563 1563 1563 1574 AME VALUE A A DIP WITCH POITION CONTINUOU FAN 24 VAC INPUT (R) ON G ONLY 1229 1278 1262 1246 1352 1406 1388 1371 1106 1150 1136 1121 979 985 973 949 1077 1113 1099 1072 881 887 876 854 866 845 826 787 953 930 909 866 779 761 743 708 780 734 711 519 858 807 782 571 702 661 640 467 COOLING OR HEAT PUMP HEATING MODE---INGLE PEED OR 2---PEED HIGH 24 VAC INPUT (R) ON Y/Y2 AND O (FOR COOLING) (TON) 1747 1747 1733 1733 * 5.0 1922 1922 1906 1906 ** 1572 1572 1560 1560 1339 1378 1378 1359 * 4.0 1473 1516 1516 1495 B (1 = ON, 2 = OFF)*** 1205 1240 1240 1223 1151 1186 1151 1142 3.5 1266 1305 1266 1256 1036 1067 1036 1028 D(1=ON,2=ON)* 1014 997 985 954 D(1=ON,2=ON)** 3.0 1195 1097 1084 1049 D (1 = ON, 2 = ON)*** 913 897 887 859 NOTE: In cooling---dehumidification mode, with no 24VAC input to DH, the CFM is reduced 15%. 9

IZE 120 AIRFLOW DATA (CFM) (CONTINUED) COOLING OR HEAT PUMP HEATING MODE---2---PEED LOW 24 VAC INPUT (R) ON Y1 AND O (FOR COOLING) (TON) 911 898 878 853 * 5.0 1002 988 966 938 ** 820 808 790 768 767 720 685 645 * 4.0 844 792 754 710 B (1 = ON, 2 = OFF)*** 690 648 617 581 677 636 592 549 3.5 745 700 651 604 609 572 533 494 D(1=ON,2=ON)* 596 560 515 474 D(1=ON,2=ON)** 3.0 656 616 567 521 D (1 = ON, 2 = ON)*** 536 504 464 427 NOTE: In cooling---dehumidification mode, with no 24VAC input to DH, the CFM is reduced 15%. DELAY PROFILE FOR OIL HEATING MODE W4 --- DELAY HEAT INPUT (UGPH) PreRun On --- Delay CFM Level --- Time hortrun On --- Delay CFM Level --- Time Off --- Delay CFM Level --- Time** A(1=OFF,2=OFF) 0.85 13% --- 45 sec. 44% --- 30 sec. 38% --- 3 min. B(1=ON,2=OFF) 1.00 13% --- 30 sec. 44% --- 30 sec. 38% --- 3 min. C(1=OFF,2=ON) 1.10 13% --- 30 sec. 50% --- 30 sec. 38% --- 3 min. D(1=ON,2=ON) All 13% --- 30 sec. 100% --- 0 sec. 100% --- 2 min. DELAY PROFILE FOR COOLING OR HEAT PUMP HEATING MODE No adjustment required A/C size PreRun On --- Delay CFM --- Level --- Time hortrun On --- Delay CFM Level --- Time Off --- Delay CFM Level --- Time All 13% --- 30 sec. 75% --- 2.5 min. 50% --- 3 min. * CFM with W3---ADJ Dip witch A Position. **CFM with W3---ADJ Dip witch B Position. ***CFM with W3---ADJ Dip witch C Position. { PreRun is the time with 0 CFM after the call for cooling or heating. The hortrun come after the PreRun. } hortrun is the time before the blower starts at normal speed, with very low CFM to minimize cool draft in the air distribution system. {{ Off---Delay is the time required to cool down the coil (heating mode), with low CFM to minimize cool draft in the air distribution system. 10

IZE 120 POWER DRAW (WATT) W1 --- HEAT HEAT INPUT (UGPH) OIL HEATING MODE 24 VAC INPUT (R) ON W ONLY POWER DRAW (WATT) A(1=OFF,2=OFF) 0.85 278 406 485 562 B(1=ON,2=OFF) 1.00 472 594 668 752 C(1=OFF,2=ON) 1.10 605 731 823 933 D(1=ON,2=ON) AME VALUE A A DIP WITCH POITION NOTE: W3---ADJ set in witch position A. (TON) CONTINUOU FAN 24 VAC INPUT (R) ON G ONLY POWER DRAW (WATT) A(1=OFF,2=OFF) 5.0 222 341 400 464 B(1=ON,2=OFF) 4.0 131 218 287 335 C(1=OFF,2=ON) 3.5 107 188 242 278 D(1=ON,2=ON) 3.0 90 159 202 242 NOTE: W3---ADJ set in witch position A. COOLING OR HEAT PUMP HEATING MODE---INGLE PEED OR 2---PEED HIGH 24 VAC INPUT (R) ON Y/Y2 AND O (FOR COOLING) POWER DRAW (WATT) (TON) A(1=OFF,2=OFF) 5.0 525 641 743 832 B(1=ON,2=OFF) 4.0 269 394 469 529 C(1=OFF,2=ON) 3.5 193 298 348 406 D(1=ON,2=ON) 3.0 149 226 291 347 NOTE: W3---ADJ set in witch position A. COOLING OR HEAT PUMP HEATING MODE---2---PEED LOW 24 VAC INPUT (R) ON Y1 AND O (FOR COOLING) POWER DRAW (WATT) (TON) A(1=OFF,2=OFF) 5.0 120 197 252 300 B(1=ON,2=OFF) 4.0 92 155 197 244 C(1=OFF,2=ON) 3.5 71 135 173 210 D(1=ON,2=ON) 3.0 67 121 152 192 NOTE: W3---ADJ set in witch position A. 11

DIMENION 21 1 4 20" 20" 20" VENT CONN D 3" E 10" C B A A98009 DIMENION (IN.) UNIT DIMENION RETURN UPPLY UNIT FLUE HEIGHT OPENING OPENING VENT DEPTH HEIGHT IZE WIDTH CONN A B C D E 105---12 21---1/4 53---3/4 31---1/2 26---1/2 20 20 5 120---20 21---1/4 60---5/32 34---3/4 28---11/32 22 24 6 12

ACCEORIE A97432 CONTROL: THERMOTAT AND ZONING Available in programmable and non---programmable models, Carrier thermostats maintain a constant, comfortable temperature level in the home. For the ultimate in home comfort, Carrier s 2, 4, and 8---zone systems allow temperature control of individual zones of the home. This is accomplished through a series of electronic dampers and remote room sensors. The 4---zone system is shown. ENERGY/HEAT RECOVERY VENTILATOR A94336 Carrier s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level. Especially useful for today s tighter constructed houses. Energy recovery ventilator is shown. A97380 ELECTRONIC OR MECHANICAL AIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. aves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner. Electronic air cleaner is shown. HUMIDIFIER A91365 By adding moisture to winter--- dry air, Carrier humidifier can often improve comfort and keeps woodwork, wallpaper, and paint in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperatures. KLABV0201DET Blocked Vent hutoff Kit FURNACE ACCEORIE TP --- PRH01 --- A TC --- PAC01 TC--- PHP01 TP --- NRH01 --- A TC --- NAC01 TC --- NHP01 ZONECC2KIT01--- B ZONECC4KIT01--- B ZONECC8KIT01--- B HUMCCBP2312 HUMCABP2312 HUMCCLBP2317 HUMCALBP2317 HUMCCLFP1318 HUMCALFP1318 HRVCCHA1100 PROGRAMMABLE THERMOTAT ELECTION Thermostat, Auto changeover 7--- Day Programmable, F/ C, 3 --- tage Heat/2 --- tage Cool, Relative Humidity Thermostat, Auto Changeover, 5--- 2--- Day Programmable, F/ C, 1 --- tage Heat/1 --- tage Cool Thermostat, Auto Changeover, 5--- 2--- Day Programmable, F/ C, 2 --- tage Heat/1 --- tage Cool NON---PROGRAMMABLE THERMOTAT ELECTION Thermostat, Auto Changeover, Non--- Programmable, F/ C, 3 --- tage Heat/2 --- tage Cool, Relative Humidity Thermostat, Auto Changeover, Non--- Programmable, F/ C, 1 --- tage Heat/1 --- tage Cool Thermostat, Auto Changeover, Non--- Programmable, F/ C, 2 --- tage Heat/1 --- tage Cool ZONING CONTROL ELECTION Comfort Zone II--- B --- 2 Zone Kit/Temperature and Humidity Control Comfort Zone II--- B --- 4 Zone Kit/Temperature and Humidity Control Comfort Zone II--- B --- 8 Zone Kit/Temperature and Humidity Control HEALTHY HOME OLUTION Humidifier --- 12 g./day, 24V tandard, mall Bypass Humidifier --- 12 g./day, 24V Automatic, mall Bypass Humidifier --- 17 g./day, 24V tandard, Large Bypass Humidifier --- 17 g./day, 24V Automatic, Large Bypass Humidifier --- 18 g./day, 24V tandard, Fan Powered Humidifier --- 18 g./day, 24V Automatic, Fan Powered Heat Recovery Ventilator --- mall Horizontal Unit, 100 CFM 13

ACCEORIE (CONTINUED) HRVCCVA1100 Heat Recovery Ventilator --- mall Vertical Unit, 100 CFM HRVCCLHA1150 Heat Recovery Ventilator --- Large Horizontal Unit, 150 CFM HRVCCLHA1250 Heat Recovery Ventilator --- Large Horizontal Unit, 250 CFM HRVCCVU1150 Heat Recovery Ventilator --- mall Vertical Unit, 150 CFM HRVCCVU1200 Heat Recovery Ventilator --- mall Vertical Unit, 200 CFM HRVCCLVU1150 Heat Recovery Ventilator --- Large Vertical Unit, 150 CFM HRVCCLVU1200 Heat Recovery Ventilator --- Large Vertical Unit, 200 CFM HRVCCLVU1330 Heat Recovery Ventilator --- Large Vertical Unit, 330 CFM ERVCCHA1100 Energy Recovery Ventilator --- mall Horizontal Unit, 100 CFM ERVCCVA1100 Energy Recovery Ventilator --- mall Vertical Unit, 100 CFM ERVCCLHU1150 Energy Recovery Ventilator --- Large Horizontal Unit, 150 CFM ERVCCLHU1200 Energy Recovery Ventilator --- Large Horizontal Unit, 200 CFM EZXCABCC1016 Media Filter Cabinet --- 1600 CFM (Replacement Filter: EXPXXFIL0016) EZXCABCC1020 Media Filter Cabinet --- 2000 CFM (Replacement Filter: EXPXXFIL0020) TYPICAL INTALLATION AIR CONDITIONER OR HEAT PUMP UPPLY-AIR DUCT RETURN-AIR DUCT OIL TANK A/C COIL CHIMNEY LOW-BOY OIL FURNACE FLUE PIPE AIR FLOW A98010 Copyright 2010 Carrier Corp. 7310 W. Morris t. Indianapolis, IN 46231 Printed in U..A. Edition Date: 11/10 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: ---5PD Replaces: ---4PD 14