Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Similar documents
Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

Model 600 Operation & Maintenance Manual

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

Operation & Maintenance Manual

ARCHITECTURAL SPECIFICATIONS

SECTION AIR DUCT ACCESSORIES

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SECTION INTRUSION DETECTION SYSTEM

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

SECTION (15767) - UNIT HEATERS

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

SECTION FIRE EXTINGUISHER CABINETS

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

DIVISION 10 SPECIALTIES

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION DOMESTIC WATER PUMPS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

DONALD H. BERG, ARCHITECT

SECTION FAN COIL UNITS

ARBOR SERIES WOOD WALLCOVERINGS

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SECTION ELECTRIC FLOOR HEATING AND SNOW MELTING EQUIPMENT

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

SECTION FIRE-RATED GLASS AND FRAME

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

UFGS (August 2008) UFGS (January 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS

ARBOR SERIES DIVISION FLEXIBLE WOOD VENEER WALLCOVERING

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

SECTION INTEGRATED DOOR ASSEMBLIES

Design & Construction Standards, Revised January

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

WALLCOVERINGS WALLCOVERINGS

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

FIRE & LIFE SAFTEY STANDARD

NFPA 80 Overview January 21, 2016

SECTION AIR DOORS

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

SECTION AIR COILS

CONTENTS AUTOMATIC TRANSFER SWITCHES

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

LIGHTING CONTROL DEVICES

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

15900 HVAC INSTRUMENTATION AND CONTROLS

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

DIVISION LOW VOLTAGE DE-ICING / SNOW MELTING SYSTEM IN EXISTING ASPHALT/CONCRETE

SECTION COMMERCIAL-KITCHEN HOODS

SECTION LIGHTING CONTROL DEVICES

Linear Heat Detection Engineering Specifications

PART GENERAL 1.01 SECTION INCLUDES

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Design & Construction Standards, Revised January

University of Rochester October 17, 2008 Brooks Landing Business Center

Product Guide Specification

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

SECTION OVERHEAD COILING FIRE DOORS

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

WEST VIRGINIA UNIVERSITY

EcoAisle Thermal Containment System

B. Section Identification for Fire Suppression Piping and Equipment.

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

SECTION ISOLATED POWER SYSTEMS

XRRS Specification Fire Ready Hood

SECTION OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION SPRINKLER SYSTEMS

Construction Standards Page

Addendum # 2 Wicomico County Circuit Court Second Floor Renovations Date of Addendum: 2/6/2017

SECTION Overhead Coiling Doors

Product Guide Specification

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

National Reach. Local Service.

FIRE/SMOKE BARRIER FUNDAMENTALS

1.3 REFERENCE STANDARDS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

SECTION ENCLOSED CONTROLLERS

Transcription:

SMOKE GUARD SYSTEM MODEL 200 SPECIFICATION Smoke Guard inc. 287 N. Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.639.7851 e-mail: info@smokeguard.com website: http://www.smokeguard.com/ MasterFormat 2005 Location: Recommended location under the current MasterFormat 2004 is Section 08 3483 Elevator Door Smoke Containment System. CSI does not recommend the Division 07 location 07 8700 Smoke Containment Barriers since this is for static smoke containment systems. Smoke Guard products are active smoke containment systems of operable doors tied into fire and smoke alarms systems very similar to overhead coiling fire doors. This recommendation has been vetted by a number of nationally recognized MasterFormat experts, active specification consultants, and the staff of CSI involved with maintaining MasterFormat. SECTION 08 3483 ELEVATOR DOOR SMOKE CONTAINMENT SYSTEM PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: Smoke detector activated elevator door smoke containment screen and control system designed to provide a tight-fitting, smoke- and draft-control assembly. B. Products Supplied But Not Installed Under This Section: 1. End-of-line diode (3.9V, 2W). Installed at smoke detector to monitor the circuit. C. Related Sections: 1. 09 2200 Non-Load Bearing Wall Framing: Metal backing in housing mounting area. 2. 09 9100 Paints: Field painting of specified components. 3. 28 3000 Detection and Alarm: Provision of smoke detectors. 4. 14 2100 Electric Traction Elevators. 5. 14 2400 Hydraulic Elevators. 6. Division 26 Sections for 120VAC and control circuit power including conduit, boxes, conductors, wiring devices, and emergency power. 1.02 REFERENCES A. ASTM A240/240M Standard Specification for Heat Resisting Chromium and Chromium- Nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels. Doc # 204_04, Rev 5, 3/5/2013 08 3483-1 Elevator Door Smoke Containment System

B. ICC Evaluation Service ES-AC77 Acceptance Criteria for Smoke-Containment Systems Used With Fire-Resistive Elevator Hoistway Doors and Frames. C. ICC Evaluation Service report ESR-1136 D. NFPA Codes and Standards: 1. 70 National Electrical Code. 2. 105 Recommended Practice for the Installation of Smoke-Control Door Assemblies. 3. 72-2002 and 2007 National Fire Alarm Code E. International Building Code 1. 2003. 2. 2006 3. 2009 4. 2012 F. UL Standards: 1. 268 Smoke Detectors for Fire Protective Signaling Systems. 2. 508 Industrial Control Equipment. 3. 864 Control Units for Fire Protective Signaling Systems. 4. 1784 Air Leakage Tests for Door Assemblies. 1.03 SUBMITTALS A. Reference Section 01 3300 Submittal Procedures; submit following items: 1. Product Data. 2. Shop Drawings: Include door width and height, jamb width, jamb and head projection, screen width, mounting height, and housing width. Show and identify related work performed under other sections of the specifications. 3. Quality Assurance/Control Submittals: a. Qualifications: 1) Proof of manufacturer qualifications. 2) Proof of Installer qualifications. b. Certifications: Copy of specified items. c. Manufacturer s installation instructions and testing procedures 1.04 CLOSEOUT SUBMITTALS A. Comply with Section 01 7700 Closeout Submittals; submit following items: 1. Operation and Maintenance [Manual][Video]. 2. Manufacturer s Warranties 1.05 QUALITY ASSURANCE A. Overall Standards: 1. Manufacturer shall maintain a quality control program in accordance with ICC-ES Acceptance Criteria 77. B. Qualifications: 1. Manufacturer Qualifications: Minimum seven years experience in producing smoke containment systems of the type specified. 2. Installer Qualifications: Factory trained by manufacturer. Doc # 204_04, Rev 5, 3/5/2013 08 3483-2 Elevator Door Smoke Containment System

C. Certifications: 1. Manufacturer s ICC Evaluation Service report ESR-1136 showing compliance with: a. ICC-ES AC77 b. UL standard 1784 c. AST, E84 d. NFPA 105 2. IAS (IAS is a trademark of International Accreditation Service) Accredited Testing Laboratory Labels for UL Standard 1784 3. IAS (IAS is a trademark of International Accreditation Service) Accredited Testing Laboratory Labels for UL Standard 864 4. California Department of Forestry and Fire Protection and Office of the State Fire Marshal Listing. 5. OSHPD Anchorage Pre-Approval No. OPA-0318 D. Pre-Installation Meeting: Include painting sub-contractor in following paragraph if auxiliary rails will be field painted. 1. Schedule and convene a pre-installation meeting prior to commencement of field operations with representatives of the following in attendance: Owner, Architect, General Contractor, smoke containment system sub-contractor, painting sub-contractor, and electrical sub-contractor. 2. Review substrate conditions, requirements of related work, installation instructions, storage and handling procedures, and protection measures. 3. Keep minutes of meeting including responsibilities of various parties and deviations from specifications and installation instructions. 1.06 DELIVERY, STORAGE, AND HANDLING A. Comply with Section 01 6600 Delivery, Storage, and Handling. B. Comply with manufacturer s instructions. 1.07 WARRANTY A. Provide manufacturer s standard one year warranty. B. Maintenance and Testing: 1. Perform minimum semi-annual maintenance and testing on each smoke containment system as required by the manufacturer s warranty, code agency evaluation reports, and as required by local authority having jurisdiction. 2. Provide test documentation. PART 2 - PRODUCTS 2.01 MANUFACTURED UNITS A. Model 200 B. Manufacturer: 1. Smoke Guard, 287 Maple Grove, Boise, Idaho 83704 http://www.smokeguard.com/ 2. Doc # 204_04, Rev 5, 3/5/2013 08 3483-3 Elevator Door Smoke Containment System

Insert name, address and phone numbers of local distributor. Local distributor can be found at www.smokeguard.com C. Label each smoke containment system with following information: 1. Manufacturer s name. 2. Maximum leakage rating at specified pressure and temperature conditions. 3. Label of quality control agency. 2.02 PERFORMANCE A. Air Leakage: Not to exceed 3 cfm (0.001416 m 3 /s) per sf of door opening at 0.1 in (25 Pa) water pressure differential at ambient temperature and 400 degrees F (204 degrees C) tested per IBC 2006, 2009, and 2012. 2.03 COMPONENTS A. Screen: 1. Film: Minimum 1 mil (0.025 mm) thick transparent polyimide film reinforced with minimum 100 denier Nomex yarn at.25 in (6.35 mm) each way. 2. Magnetic Strips: Flexible multi-pole strips attached to longitudinal edges of film with low modulus silicone adhesive. B. Housing: 20 gage, powder coated, cold rolled steel container with dust cover and door with concealed hinges and a latch. Housings are 55 inches or 64 inches in length, plus 1-1/2 inches for a junction box on the left side. Auxiliary rails are required if painting of rails is required, include following field painting requirement in section 09 9100: Paint must be heat resistant to 300 degrees f (149 degrees c) and be spray applied, maximum 5 mils (.13 mm) thick including primer. C. Mandatory Auxiliary Rails: 1. Material: 16 gage ASTM A 240/240M, Type 430, ferritic stainless steel. 2. Size: 2 in (51 mm) wide, 1 (25 mm) deep, as shown in Shop Drawings. D. Rewind Motor: NFPA 70, 90v DC. E. Release Mechanism: IAS ( IAS is a trademark of International Accreditation Service) Accredited Testing Laboratory Labels for UL Standard 864 F. Screen Rewind Switch: Include switch to rewind screen into housing. PART 3 - EXECUTION 3.01 EXAMINATION A. Examine substrates upon which work will be installed. 1. Verify related work performed under other sections is complete and in accordance with Shop Drawings. 2. Verify wall surfaces and elevator door frames are acceptable for installation of smoke containment system components. Doc # 204_04, Rev 5, 3/5/2013 08 3483-4 Elevator Door Smoke Containment System

B. Coordinate with responsible entity to perform corrective work on unsatisfactory substrates. C. Commencement of work by installer is acceptance of substrate. 3.02 INSTALLATION Manufacturer s installation instructions cover procedures for normal installation and assume the design and detailing complies with smoke guard system requirements. Unusual conditions or variations from Smoke Guard system requirements should be added to this article. A. Install smoke containment system components in accordance with manufacturer s installation instructions. 3.03 FIELD QUALITY CONTROL A. Field Test: Follow manufacturer s cycle test procedures. 1. Notify Owner s Representative, local Fire Marshal, alarm sub-contractor and [elevator sub-contractor] [elevator service company] minimum one week in advance of scheduled testing. 2. Complete maintenance service record. 3.04 DEMONSTRATION A. Demonstrate required testing and maintenance procedures to Owner s Representative. B. Maintenance and Testing: 1. Perform minimum semi-annual maintenance and testing on each smoke containment system as required by the manufacturer s warranty, code agency evaluation reports, and as required by local authority having jurisdiction. 2. Retain permanent record of tests. C. Future Painting: Paint elevator door frame and/or auxiliary rails in accordance with Operation and Maintenance Manual. D. Qualified Smoke Guard Inspector assesses unit(s) after exposure to a fire event. END OF SECTION Doc # 204_04, Rev 5, 3/5/2013 08 3483-5 Elevator Door Smoke Containment System