CUH-11 CABINET UNIT HEATERS

Similar documents
BCUH-14R. Cabinet Unit Heaters. STEAM and HOT WATER

BCUH-15. Cabinet Unit Heaters. STEAM and HOT WATER

Cabinet Unit Heaters Steam / Hot Water

Cabinet Unit Heater Options Booklet

TCV-1. Convector Steam and Hot Water Unit Heaters

Product Specifications. Vertical Floor Consoles By First Co.

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-13

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

SeasonMaker ThinLine Fan-coil Units

Convectors Steam / Hot Water November, 2009

FAS Fresh Air Supply Units

SeasonMaker ThinLine Fan-coil Units

VERTICAL STEAM AND HOT WATER UNIT HEATERS

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

Cabinet Unit Heaters Type CHF & CHB

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Incremental Comfort Conditioners

VERTICAL FAN COIL UNITS

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS

CWA4 Chilled & Hot Water Fan Coil

Modular Supply Make-Up Air Unit

SECTION CONVECTION HEATING AND COOLING UNITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

STEAM/HOT WATER UNIT HEATERS

Hydronic Heating Solutions

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

KIC Air Curtains. Technical Guide

Direct Gas-Fired Make-Up Air

Refer to page 9 for information regarding the Breeze TM AccuSpec Sizing and Selection Program

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Indirect Gas-Fired Make-Up Air

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Cabinet Unit Heaters

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

PACKAGE AIR CONDITIONER

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Concealed Ducted Split Series R-407C MBH

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

MAC-120HE-03 Air-Cooled Chiller

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Econo-Line Enclosures

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

Boiler & Water Heater

HYDRONIC HEATING CATALOG

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

VertiCool Aurora Engineering Guide

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

WALL-MOUNT HEAT PUMPS - (60HZ)

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Q-TEC QC-Series Chilled Water Air Conditioner

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

JCseries EVAPORATIVE CONDENSER. engineering data

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

SKYPAK II, 3 Ton Series, gives you a

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

FCC Fan-Coil Units High-Performance, Vertical

EHH SERIES DRAW THROUGH FAN COILS CFM

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Vertical V*B Series Fan Coil Technical Catalog

SAS Steadyair Make-Up Air Units Technical Guide

Q-Tec TM QC-Series Chilled Water Air Conditioner

JH Series Installation

GREEN REFRIGERANT R-410A

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Commercial High-Efficiency Condensing Units

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

COMMERCIAL AIR HANDLER

SKYPAK II, 3 Ton Series, gives you a

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Direct Fired Heater Model AD Specification

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

MACH N-407 Heat Pump Air-Cooled Chiller

Commercial High-Efficiency Condensing Units

Transcription:

CUH- CABINET UNIT HEATERS Steam and Hot Water

CABINET UNIT HEATERS SELECTION AND "ROUGH IN" MADE EASY - ONLY THE LENGTHS VARY The Beacon-Morris Cabinet Unit Heater is the industry s most recent design. Years of manufacturing and engineering experience combined with a concern for appearance have resulted in a crisply styled unit that will blend with almost any room decor and provide reliability, durability, individual control and quiet operation. As unit size increases, only the length changes. The depth and height remain constant, thus allowing the designer to have uniformity of appearance when units of various sizes are installed in adjacent areas. The wide selection of floor, wall and ceiling units with a variety of air flow arrangements allows for exactly matching design requirements. The pedestal base for floor models is the height of most mop boards. Field repainting to match the decor is possible and factory applied decorator colors are available as an option. Recessed models are provided with a field installed wall seal that allows for full or partial recessing depending on the model. The wall seal kit is also available as an option for full or partial recessing of most other models. The solid state speed control provides infinite variations from high to low speed, giving the occupant finger tip control over fan speed and room temperature. All units are CSA certified. The standard 6 gauge front panel is rugged enough to withstand harsh treatment. Exposed cabinetry is provided with a prime coat of neutral eggshell baked enamel, which in many instances can serve as the finish. Back and side panels are 8 gauge. 2

0 MODELS - 28 ARRANGEMENTS - 8 CFM SIZES F FI FLOOR TYPE FLOOR TYPE, INVERTED FLOW FS FSI FLOOR TYPE SLOPE TOP FLOOR TYPE SLOPE TOP, INVERTED FLOW W & WI RW & RWI WALL TYPE and INVERTED FLOW RECESSED WALL and INVERTED FLOW C RC CEILING MOUNTED RECESSED CEILING MOUNTED See page 6 for arrangements. 3

CABINET UNIT HEATER STANDARD FEATURES - Adjustable wall seal to suit recessing requirements. - Copper Aluminum coil for steam or hot water. - Support bracket to wall. - Whisper quiet blowers. - Cabinet finish neutral eggshell baked powder. - Leveling legs optional. - Motors - Permanent split capacitor. - 6 Gauge steel front panel with insulation, standard. - Permanent washable filter, aluminum fiber media. - Outside air knockout provided standard on F and FS models. - Speed Control / Access doors - Standard on all floor and wall models. - Steam Coil (Standard) - Brazed copper tube and header with aluminum fin. Factory tested to 250 PSI. - Access Area. - Optional High Capacity 2 row coil. 4

CABINET UNIT HEATERS RATINGS AND SPECIFICATIONS WALL SEAL - The optional wall seal kit with gasket is designed to allow for easy installation and permanent protection for the wall board, plaster or sheet rock surrounding the unit on recessed models. COILS - STANDARD ONE ROW - The durable mechanically bonded copper/aluminum coil presents the best of todays hydronic technology. Providing 2 fins per inch with /2" nominal diameter tubes, the ultimate in BTU capacity is provided without sacrificing noise, vibration or amp draw. All element assemblies are submersion tested at factory at 250 P.S.I. and are rated at a working pressure of 50 pounds of saturated steam pressure at 298 F. All units are designed so that field modifications can be made to reverse the coil position if required. HIGH CAPACITY COIL - This is a hot water coil designed to provide increased capacity when the required load exceeds that of the standard coil for a given size. Its construction is similar to the standard coil; however, fins are double depth and there are two rows of tubes. Element assemblies are submersion tested at 250 p.s.i. and are rated at a working pressure of 50 p.s.i. and 298 F. BLOWER FAN HOUSING - The blower fan assembly provides one of the industry s best CFM output per unit size. Operating amperage ranges from.9 amps on the 200 CFM unit up to 3.2 amps on the 400 CFM unit at 5 volts. The whisper quiet blower assembly is made with electro galvanneal steel, providing long life and durability. MOTOR - All motors are (PSC) permanent split capacitor. This provides the ultimate in motor life, operating cost, noise levels and dependability. A standard shaft size of /2" diameter is the same on all motors. By using a solid state variable speed switch, a range of speeds can be achieved. Motors are either /5 or /0 H.P. FILTER - The standard permanent filter is made of durable aluminum which has an average arrestance of 69%. Light and easy to handle, the filter slides into its locating channel and is permanently held in position with a factory supplied cotter pin. FRONT PANEL - #6 gauge front panel is standard with " - -/2 lb. density, neoprene one side insulation in front of the coil. Full panel insulation is available as an option. Tamper resistant fasteners are also available. MOTOR/BLOWER SHELF - Support shelf adds support to units strength and structural integrity. A support gusset is supplied with 600 CFM units and up. FINISH - Standard finish is an aesthetically pleasing neutral eggshell baked powder, which is suitable for field repainting if necessary. Optional colors available as shown on color chart. LEVELING LEG - Optional leveling legs are available. Four (4) legs per unit allow adjustment for pitch and yaw when unit is mounted on uneven floors. SPEED CONTROL / ACCESS DOOR - The solid state speed control allows infinite speed selection for comfort control. Located under the finger touch access door, the speed control is out of view yet easily accessible. The access door requires just the pressure of a finger to open and swings 20 to a stay open position. The access door comes with a standard knurled knob fastener and is available with optional tamper resistant fastener. Speed control switch is not mounted on C or RC units. ACCESS AREA - A spacious rough-in area is provided between the unit ends and the internal cabinet at both ends. The removable front panel allows full access to the piping and valve area (left-hand standard) and to the wiring, switch area. Right hand shown. The rear portion is enclosed with sheet metal. HINGED PANEL / CEILING UNIT - The hinged panels on all ceiling units are standard. Stop chains are standard. Speed control switches are shipped inside unit with wiring diagram. Switch can be mounted internal or remote from unit. CONSTANT CABINET DIMENSIONS - Throughout the design of the cabinet unit heater, one feature has been a primary concern - "uniformity." The cabinet depth is one dimension on all unit sizes. Along with that, the cabinet height is constant on all units except FS and FSI. Only the length changes on these models. The internal cabinet allows for all controls and piping to be reversible by making all locator and fastener holes in mirror image. SLOPING TOP CABINETS - Best feature for areas that cannot tolerate accumulations of books, cups, paper, etc. 5

CABINET UNIT HEATERS MODELS AND AIRFLOW ARRANGEMENTS MODEL ARRANGEMENT NUMBER FLOOR F F-000 F-00 F-020 F-030 25% F.A. See options 8 & 9 25% F.A. FLOOR INVERTED FLOW FI FI-040 FI-050 SLOPE FS FS-005 FS-05 FS-025 FS-035 25% F.A. See options 8 & 9 25% F.A. SLOPE INVERTED FLOW FSI FSI-045 FSI-055 WALL W W-060 W-070 W-080 WALL INVERTED FLOW RECESSED WALL WI RW WI-090 WI-00 WI-0 RECESSED WALL INVERTED FLOW RWI RW-20 RWI-30 CEILING C C-40 C-50 C-60 C-70 C-80 RECESSED CEILING RC RC-90 RC-200 RC-20 CAT00207 MODELS, ARRANGEMENTS AND SIZES ARE DESIGNATED AS FOLLOWS: EXAMPLE - RC - 90-08 SIZE 6 MODEL ARRANGEMENT SIZE CFM 02 03 04 06 08 0 2 4 200 300 400 600 800 000 200 400

CABINET UNIT HEATERS RATINGS AND SPECIFICATIONS TABLE I UNIT SIZE HEATING CAP. - HOT WATER MBH 20 WTD GPM HIGH CAP. - COIL 2 ROW HEATING CAP. MBH HOT WATER GPM 20 WTD. HEATING CAP. - STEAM 2 PSIG MBH STANDARD EDR COIL COND. LB/HR COIL: NUMBER FINS PER INCH FACE AREA-FT 2 COIL CONNECTIONS BLOWERS: NUMBER DIAMETER/WIDTH DRIVE HI RPM - LOW CFM: HIGH LOW MOTOR: H.P. NUMBER VOLTS/PHASE/HERTZ AMPERES CONTROLS - STD. FILTER: NO. TYPE LENGTH WIDTH THICKNESS db. LEVEL 8" FROM UNIT LENGTH HEIGHT DEPTH 02 6.4.64 25.8 2.58 22.6 94 23.4 2.97 -/4CU 5-3/4 / 7 DIRECT 050 875 230 85 /5 5//60.8 VAR. PERM. 9-3/4 8-/6 /2 50 35 25 9-/2 ENTERING WATER - 200 ENTERING AIR - 60 03 04 06 08 0 2 4 22.8 2.28 35.4 3.54 3.4 3 32.5 2.5 -/4CU 5-3/4 / 7 DIRECT 050 875 335 270 /5 5//60.8 VAR. PERM. 27-3/4 8-/6 /2 52 43 25 9-/2 29.8 2.98 46.3 4.63 4.0 7 42.4 2.8 -/4CU 2 5-3/4 / 7 DIRECT 050 875 430 345 /0 5//60.4 VAR. PERM. 3-3/4 8-/6 /2 53 47 25 9-/2 48.0 4.80 69.8 6.98 66. 276 68.4 2 2.6 -/4CU 2 5-3/4 / 7 DIRECT 050 875 630 505 /0 5//60.4 VAR. PERM. 43-3/4 8-/6 /2 54 59 25 9-/2 CABINET UNIT HEATERS SHIPPING WEIGHT (LBS) 54.5 5.46 87.6 8.76 75. 33 77.7 2 2.8 -/4CU 3 5-3/4 / 7 DIRECT 050 875 860 685 @ /0 @ /5 2 5//60 2.2 VAR. PERM. 45-3/4 8-/6 /2 55 6 25 9-/2 62.0 6.20 0.8 0.8 85.4 356 88.4 2 3. -/4CU 3 5-3/4 / 7 DIRECT 050 875 060 845 @ /0 @ /5 2 5//60 2.2 VAR. PERM. 50-3/4 8-/6 /2 55 66 25 9-/2 75.6 7.56 9.8.98 04. 434 07.7 2 3.6 -/4CU 4 5-3/4 / 7 DIRECT 050 875 230 985 /0 2 5//60 2.8 VAR. PERM. 57-3/4 8-/6 /2 56 73 25 9-/2 78.5 7.85 28.6 2.86 08.2 45 2 2 4.4 -/4CU 4 5-3/4 / 7 DIRECT 050 875 40 30 /0 2 5//60 2.8 VAR. PERM. 69-3/4 8-/6 /2 56 85 25 9-/2 SIZE STYLE 02 03 04 06 08 0 2 4 F-FI 92 09 22 48 66 76 96 22 FS-FSI 94 24 50 68 78 98 223 W-WI-RW-C 97 5 28 57 75 85 207 234 RC 02 2 35 64 83 94 25 243 7

47.2 27.6 20.0 6. 3.8 38.2 26.4 20. 6.6 4. 38.0 23.9 20.5 3.7.3 35.7 26.5 2.0 7.5 5.0 42.0 3.0 24.2 6.4 2.8 33.5 26.8 8.2 4..8 32.6 22.2 7.0 3.8.6 37.9 34.2 23.3 4.5 2.2.8 3.8 5.0 6. 7.3 9. 9.8 20. 20.7 2. 9.0 23.9 25.8 27.4 28.3 35.7 39.8 4.9 43.6 44.6 42.0 46.5 48.3 49. 5.2 50.2 53.5 54.7 56.3 58.9 65. 66.6 68.0 69.0 69.7 66.3 68.4 69.9 72.5 73.0 20 25 30 35 8 20 22 25 26 06 7 22 26 29 9 25 29 32 34 0 5 7 20 22 09 2 4 6 7 3 6 7 8 9 06 08 3 3 5.2 30.2 2.6 7.4 5.0 42.6 26.6 22.7 8.8 5.8 43.6 26.6 23.2 5.4 2.9 40.4 29.8 23.6 9.8 6.9 47. 34.8 26.9 8.6 4.4 32.7 30.2 20.7 6.0 3.2 35.7 24.8 9. 5.5 3. 40.6 37.0 25.9 6.2 3.6 2.8 5. 6.2 7.4 8.8 2.3 22.0 22.7 23.5 23.8 2.8 26.6 29.0 30.9 32.3 40.4 44.8 47.2 49.4 50.7 47. 52.2 53.9 56.0 57.8 55.8 60.4 62.2 64. 66.0 7.5 74.5 76.7 77.7 78.6 7.0 74. 77.6 80.9 8.7.02.06.5.24.36.07.6.26.39.55.07.27.4.00.45.30.63.0.60 2.25.3.64.0 2.25 3.85.65.5 2.35 4.00 6.00.20 2.50 4.20 6.30 8.85.00.30 2.70 6.80 9.55.5.0.5 2.0 2.5.0.5 2.0 2.5 3.0.0 2.0 2.5 4.0 5.0 2.0 3.0 4.0 5.0 6.0 2.0 3.0 4.0 6.0 8.0 3.0 4.0 6.0 8.0 0.0 4.0 6.0 8.0 0.0 2.0 3.5 4.0 6.0 0.0 2.0 LOW FAN SPEED TABLE II STANDARD COIL UNIT SIZE GPM HIGH FAN SPEED MBH WTD FAT CFM MBH WTD FAT 02 03 04 06 08 0 2 4 85 270 345 505 685 845 985 30 CFM 9 29 35 40 46 25 28 29 3 32 24 29 33 36 25 33 36 40 42 7 23 25 26 29 5 8 20 2 24 3 33 34 35 36 4 6 7 9 20 CABINET UNIT HEATERS HEATING CAPACITIES 230 335 430 630 860 060 230 40 8 WATER P.D./FT. ENTERING WATER - 200 ENTERING AIR - 60

6.5 9.9 2.4 22.5 23.5 28.3 28.9 29.7 30.3 30.8 29.5 35.8 37.8 39.7 40.8 52.7 57.0 59.7 6.2 62.0 58. 68.2 7.6 73.4 75.8 75.9 8.2 84.0 86.3 88.9 93.3 00.4 02.8 05.0 06.7 00.2 03.5 06.6.4 2.2 44 62 70 75 80 58 6 63 65 67 4 58 64 69 72 58 66 7 74 75 39 53 58 60 63 44 50 53 56 59 49 55 58 60 6 43 46 49 52 53 66.0 39.8 28.5 22.5 8.8 56.6 38.5 29.7 24.2 20.5 59.0 35.8 30.2 9.9 6.3 52.7 38.0 29.9 24.5 20.7 58. 45.5 35.8 24.5 9.0 50.6 40.6 28.0 2.6 7.8 46.7 33.5 25.7 2.0 7.8 50. 4.4 35.5 22.3 8.7 7.6 43.4 3. 24.8 20.6 60.2 42.5 33. 27.4 23.3 63.0 39.5 33.9 22.7 8.7 57.6 42. 33.0 27.6 23.2 67. 50.5 39.7 27.5 2.6 56.4 45.3 3.5 24.7 20.3 52.7 37.2 28.8 23.6 20.0 54.9 45.9 39.4 25.2 2.3 33 49 55 62 65 44 49 52 56 57 29 47 53 60 63 46 54 58 63 64 33 43 46 50 54 35 40 44 47 50 40 45 48 50 5 33 36 39 44 45.03.09.22.34.50.0.25.38.56.77..44.59.4 2.04.45.93.60 2.30 3.30.46.95.65 3.35 5.60.00.75 3.50 5.90 8.85.85 3.75 6.30 9.45 3.20 2.05 3.00 4.5 0.45 4.55 ENTERING WATER - 200 ENTERING AIR - 60.5.0.5 2.0 2.5.0.5 2.0 2.5 3.0.0 2.0 2.5 4.0 5.0 2.0 3.0 4.0 5.0 6.0 2.0 3.0 4.0 6.0 8.0 3.0 4.0 6.0 8.0 0.0 4.0 6.0 8.0 0.0 2.0 4.0 5.0 6.0 0.0 2.0 LOW FAN SPEED TABLE III HIGH CAPACITY 2 ROW COIL UNIT SIZE GPM HIGH FAN SPEED MBH WTD FAT CFM MBH WTD FAT 02 03 04 06 08 0 2 4 80 265 335 495 675 830 970 0 CFM 7.9 2.7 23.3 24.8 25.7 30. 3.9 33. 34.3 34.9 3.5 39.5 42.4 45.4 46.8 57.6 63. 66.0 69. 69.5 67. 75.8 79.3 82.6 86.5 84.6 90.6 94.6 98.6 0.6 05.3.6 5.3 8. 9.8 09.8 4.8 8.3 25.8 27.9 CABINET UNIT HEATERS HEATING CAPACITIES 225 330 420 620 845 040 20 385 9 WATER P.D./FT.

SELECTION SELECTION PROCEDURE. Determine job requirements Formulas: BTU/HR at rated conditions = a. Type of heating (steam or hot water). BTU/HR at required conditions b. Minimum heating capacity (BTU/HR or EDR). CONVERSION FACTOR 2. Select unit size F.T. (Final Air Temperature) = a. If necessary convert the required BTU/hr to rated conditions as specified in the capacity Entering Air Temp. F + BTU/HR tables. (Refer to the formulas at right). CFM x.085 b. Select unit(s) from tables with capacities equal to or slightly higher than the BTU/HR GPM (Gallons Per Minute) = required. Read directly the motor HP and BTU/HR fan RPM. Water Temperature Drop x 500 HOT WATER COIL CAPACITY EXAMPLE: EXAMPLE: STEAM COIL CAPACITY Heating load Entering air temp Entering water temp Water Flow 34,000 BTUH 60 F 80 F 2 Gpm From Table "A", page 2 Correction Factor 0.857 for 80 F water temp Equivalent capacity = 34,000 0.857 = 39673 BTUH Table II on page 8 shows selection of size 06 with 40,400 BTU at 2 GPM, sufficient for application. Heating Load 34,000 BTUH Entering Air Temp 60 F Entering Steam Pressure 0 psig From Table "A" Page correction is.3 for 0 psig. Equivalent Capacity = 34,000 = 30,088 BTUH.3 Table on Page 7 shows selection of size 03 with 3400 BTUH is sufficient for application. Actual Capacity = 3,400 x.3 = 35,482 BTUH Actual capacity = 40,400 x 0.857 = 34,622 BTUH Condensate Rate = Actual Capacity Latent Heat of Steam Final air temp 34,622 + 35,482 + 60 =0 F 630 x.085 953 = 37 lbs./hr. Final Air Temp = 35,482 + 60 = 57 F 335 x.085 STATIC PRESSURE CORRECTION FACTORS FOR BTU OUTPUT/WITH STANDARD MOTOR UNIT 0.0 ESP 0.05 ESP 0. ESP 0.25 ESP SIZE CFM BTU FACTOR CFM BTU FACTOR CFM BTU FACTOR CFM BTU FACTOR 02 230.00 205.92 65.82 45.79 03 335.00 290.92 240.82 20.79 04 430.00 390.92 35.82 275.79 06 630.00 560.92 450.82 400.79 08 860.00 750.92 620.82 540.79 0 060.00 925.92 755.82 660.79 2 230.00 060.92 865.82 750.79 4 40.00 20.92 980.82 850.79 EXAMPLE: Unit - C-50-08 output at 200 /60 = 56 MBH at 6 GPM. Static Pressure =.25, Correction factor =.79 56000 x.79 = 44,240 BTU corrected. 0 NOTE: Option 20, high static motor, maintains standard air flow with external static pressure up to 0.4'' water column.

STEAM CALCULATIONS AND CORRECTION FACTORS I. CAPACITY A. For 2 lbs. steam, 60 entering air temp. Read output directly from table I on page 7. B. For higher steam pressures and or Multiply output from table I on page 7 by E.A.T.'s above or below 60 F appropriate correction factor from table A (below). II. FINAL AIR TEMPERATURE A. For 2 lbs. steam, 60 entering air temp. See table I on page 7 for Steam MBH Capacity. See page 0 for Steam Coil Capacity example. B. For capacities calculated in I.B. (above) Output from I.B. (above).085 x CFM from Table I p.7 + E.A.T. = Final Air Temp. III. FINAL AIR VOLUME A. For 2 lbs. steam, 60 entering air temp. Read volume directly from table I on page 7. B. For final air temperatures calculated 460 + Final Air Temp from II.B. CFM @ 60 E.A.T. Final in II.B. (above) 530 x from = Air Table I on p.7 Volume IV. CONDENSATE PER HOUR A. For 2 lbs. steam, 60 entering air temp. Read lbs. per hour from table I on page 7. B. For capacities calculated in I.B. (above) Output from I.B. (above) Latent Heat From Table B = lbs. per hour of condensate TABLE A - STEAM CORRECTION FACTORS BASED ON 2 LBS. STEAM 60 E.A.T. ENTERING AIR TEMPERATURE 0 30 40 50 60 70 80 90 00.9..03 0.96 0.88 0.8 0.74 0.67 STEAM PRESSURE LBS. PER SQ. IN. (SATURATED) 2.24.6.08.00 0.93 0.85 0.78 0.7 5.29.2.3.05 0.97 0.90 0.83 0.76 0.38.29.2.3.06 0.98 0.9 0.84 5.44.34.28.9.2.04 0.97 0.89 20.50.42.33.25.7.0.02 0.95 30.60.5.43.35.27.9.2.04 40.68.60.5.43.35.27.9.2 50.70.60.58.50.42.34.26.9 TABLE B - PROPERTIES OF SATURATED STEAM STEAM PRESSURE IN POUNDS PER SQUARE INCH GAUGE 0 2 5 0 5 20 30 40 Steam Temperature- F 22.0 28.5 227. 239.4 249.8 258.8 274.0 286.7 50 297.7 Latent Heat of Steam 970 966 96 953 946 940 929 920 92

HOT WATER CALCULATIONS AND CORRECTION FACTORS I. CAPACITY @ 20 TD: A. FOR 200 E.W.T., 60 E.A.T. Read output directly from table I on page 7. B. For E.W.T. and/or E.A.T. above Multiply output from table I on page 7 or below Standard by factor from table A (below). II. CAPACITY AT OTHER TD'S Multiply output obtained in I.A. or I.B. A. For TD's from 5 to 60 F (above) by appropriate factor from table B (below). III. GPM AT OTHER TD'S Multiply GPM of unit for 20 TD A. For TD's from 5 to 60 F by appropriate factor from table B (below). IV. PRESSURE LOSS AT OTHER TD'S Multiply P.D. of unit for 20 TD A. For TD's from 5 to 60 F by appropriate factor from table B (below). TABLE A HOT WATER CONVERSION FACTORS BASED ON 200 ENTERING WATER 60 ENTERING AIR 20 TEMPERATURE DROP ENTERING AIR ENTERING WATER TEMPERATURE 20 WATER TEMPERATURE DROP TEMPERATURE 00 30 0.58 40 0.439 50 0.36 60 0.286 70 80 90 00 0.22 0.40 0.069 0 20 0.666 0.585 0.506 0.429 0.353 0.279 0.207 0.37 40 0.84 0.73 0.65 0.57 0.494 0.49 0.345 0.273 60 0.963 0.878 0.796 0.75 0.636 0.558 0.483 0.409 80.20.025 0.94 0.857 0.777 0.698 0.62 0.546 200.260.72.085.000 0.98 0.837 0.759 0.682 0.5 220.408.37.23.43.060 0.977 0.897 0.88 5.08 20.00 240.555.464.375.286.20.7.035 0.955 25.94 260.702.609.58.429.342.257.73.094 To obtain the BTU capacity for conditions other than those in the basic capacity tables, multiply the basic rating (200 when entering water, 60 entering air,) by the proper constant from the above tables. 30.90 280.850.755.663.57.483.397.3.230 TABLE B HOT WATER BTU, GPM AND PRESSURE LOSS FACTORS BASED ON STANDARD CONDITIONS OF 200 F ENTERING WATER 60 F ENTERING AIR & 20 F WATER DROP USE FACTORS FROM THIS TABLE TO OBTAIN APPROXIMATE RESULTS To obtain BTU for other Water Temperature Drops, multiply basic BTU rating by applicable Factor. 5.25 TEMPERATURE DROP F 40.83 50.76 300.997.908.824.77.630.545.462.37 60.72 To obtain GPM for other Water Temperature Drops, multiply basic GPM rating by applicable Factor. 5.00 2.30.44.00.74.59.40.30.24 To obtain Pressure Loss Feet of Water for other temperature Drops, multiply Basic loss at 20 drop by Factor. 0.00 5.00 2.00.00.60.40.20.3.07 CFM AT VARIOUS E.A.T. Entering Air Temp F 30 40 50 60 70 80 90 Conversion Factor.06.04.02.00 0.982 0.964 0.945 2

STANDARD EQUIPMENT OPTIONS & ACCESSORY EQUIPMENT BASIC UNIT 6 gauge front panel, 8 gauge ends, tops, and internal casing of electro galvanneal steel for all units; steam or hot water coil with -/4" copper tube stub ends, 5 volt PSC motor of (/0 or /5 HP.); centrifugal forward curved double width galvanized fan wheel with galvanized fan housing; variable speed fan control located right hand; permanent aluminum filter, cleanable; left hand piping (field reversible, fan switch must also be reversed); stamped louvered inlet and outlet as shown in catalog; baked enamel eggshell finish suitable for field re-painting. Air flow arrangements do not affect price. ACCESS DOORS - F, FI, FS, FSI, W, WI, units, 2 top access doors; RW, RWI units, 2 front panel access doors. Model C and RC provide no access doors in hinged front panel. FACTORY ASSEMBLED OPTIONS OPTION 0 - Limited Access Fasteners - for front panel for all models. Special tool required for opening panel. OPTION - Limited Access Fasteners - for access doors. Not applicable to models C and RC. Special tool required for opening doors. OPTION 2 - Aluminum Grille - in place of standard louver. Heavy duty bar grille has clear anodized finish and can be painted to match decorator colors if so specified. OPTION 3 - Decorator Color - may be selected from color selector. A prime coat of neutral eggshell baked powder enamel is standard unless otherwise specified. This may be the final finish or it may be painted in the field if necessary. OPTION 7 - Louvered Inlet Grille - available on models F. Recommended for aesthetics when option 8,9, 8 or 9 is ordered (standard with models FI and FSI). OPTION 8-25% Manual Outside Air Damper - outside air intake can be adjusted from 0 to 25%. Control is by manual quadrant. See Option 7. Available for field installation - see option 8. Must be ordered with models F00, FS05, F030 and FS035. Consult factory for 50% fresh air. OPTION 9-25% Motorized Outside Air Damper - opens outside air intake to 25% when blower starts. Closes when blower stops. Override switch is provided to prevent damper operation when desired. See Option 7. Available for field installation - see option 9. Must be ordered with models F00, FS05, F030 and FS035. Consult factory for 50% fresh air. OPTION 20 - High Static Motor - /H.P. -550 RPM 5//60.2 amp PSC motor. Will maintain standard air flow against 0.4'' W.C. max. See options 4 and 5. OPTION 2 - Plug In Motor - heavy duty grounded plug in cord set for connection to convenience outlet. Not CSA approved. OPTION 22 - Motor Starter - manual reset toggle switch with thermal overload. Unit must be turned off and then back on if overload trips. OPTION 23 - Disconnect Switch DPST - provides a handy means of disconnecting both hot and neutral power lines. OPTION 24F - Return Air Temperature Control - provides return air thermostat to cycle unit blower(s) if return temperature is too low. Blower shuts off when thermostat is satisfied (adjustable from 55-75 F). For Celcius order OPTION 24C. OPTION 26 - Right hand coil connection. OPTION 28 - Insulated panels applied to inside of all external panels OPTION 29 - High Capacity Coil - two row high capacity coil for hot water only. FIELD INSTALLED ACCESSORIES OPTION 4 - Inlet Duct Collar - provides flange pieces and hardware for field installation of inlet duct collar over existing louver area. Louvered area to be removed prior to installation OPTION 5 - Outlet Duct Collar - provides flange pieces and hardware for field installation of outlet duct collar over existing louver area. Louvered area to be removed prior to installation OPTION 6 - Leveling Legs - for floor mounted units - 2 per pedestal, 4 per unit. OPTION 8-25% Manual Outside Air Damper kit for field installation. See option 8 for description. Consult factory for 50% fresh air. OPTION 9-25% Motorized Outside Air Damper kit for field installation. See option 9 for description. Consult factory for 50% fresh air. OPTION 25F - Aquastat Control - strap-on aquastat keeps blower(s) off until return water temperature reaches setpoint (adjustable from 00-240 F). For Celcius order OPTION 25C. OPTION 26A & B - Wall Seal - for recessed installation, either fully or 2-/4" partial. Models where full recess would interfere with inlet and/or outlet airflow may be recessed 2-/4". See schedule below. NOTE: Wall Seal kits are furnished with models RC, RW and RWI. Kits must be ordered under this option number for all other models. WALL SEAL SCHEDULE* (see page 9) FULLY 2 /4" PARTIAL MODEL RECESSED F F 020, F 030 FI FI 050 W, RW RW 20 WI, RWI RWI 30 C, RC C 70, RC 200 RECESS F 000, F 00 FI 040 W 060, W 070 WI 090, WI 00 C 40, C 50 C 60, C 80 RC 90, RC 20 *Not Applicable to models FS or FSI. OPTION 27 - Line Voltage Room (Wall) Thermostat - T22AAA-, S.P.S.T. heating only with Off-Auto selector switch. Range 40-90 F. Rated 6.0 amps @ 20 VAC. OPTION 29 - Extra Filter - provides an additional filter (permanent aluminum mesh). One required per unit, all sizes. OPTION 26 A A B B B 3

DIMENSIONAL DATA Floor Mounted Units Models F and FI *With Top Discharge SEE PAGE 6 for other air flow arrangements. MAXIMUM RECESS DEPTH MODELS F000, F00, FI040 ONLY. 4 CAT00200

DIMENSIONAL DATA Floor Mounted Units Models FS and FSI /4" NOMINAL TYPE "L" COPPER TUBING HOT WATER RETURN /4" NOMINAL TYPE "L" COPPER TUBING HOT WATER RETURN /4" NOMINAL TYPE "L" COPPER TUBING HOT WATER SUPPLY 23 5/8" /4" NOMINAL CAT0020 TYPE "L" COPPER TUBING HOT WATER SUPPLY *With Top Discharge 9 /2" PLUMBING ACCESS DOOR TOP DISCHARGE GRILLE ELECTRICAL CONTROL ACCESS DOOR 5 7/8" 9 /8" TOP VIEW 3/8" 2 /4" 6 3/8" TWO ROW COIL PIPING DIMENSIONS. /4" 7 3/8" /4" NOMINAL TYPE "L" COPPER TUBING STEAM SUPPLY HOT WATER RETURN 5 /2" "L" SPEED CONTROL /4" NOMINAL TYPE "L" COPPER TUBING - STEAM SUPPLY - HOT WATER RETURN /4" NOMINAL TYPE "L" COPPER TUBING - STEAM RETURN - HOT WATER SUPPLY 22 3/4" 6 3/8" /4" NOMINAL TYPE "L" COPPER TUBING STEAM RETURN HOT WATER SUPPLY 28 /2" 7 /2" OPEN REF. 20" REF CL ELECTRICAL CONTROL BOX - CAN BE WIRED FROM BACK OR BOTTOM OF UNIT. 8 /4" 7/8" 4" MODEL FSI SIDE VIEW ARRANGEMENT FSI-045* /2" NOM. 9" MODEL FS SIDE VIEW ARRANGEMENT FS-005* LOUVERED INLET GRILLE IS STANDARD ON "FSI" MODELS OPTIONAL ON "FS" MODELS MODEL FS FRONT VIEW STANDARD ONE ROW COIL PIPING DIMENSIONS. "A" 6 /2" (TYP.) SIZE DIM "L" MOUNTING BRACKET SLOTS ALLOW FOR 7/6" LATERAL ADJUSTMENT 02 03 04 06 08 0 2 4 35" 43" 47" 59" 6" 66" 73" 85" H3 H2 H LOUVERED INLET GRILLE IS STANDARD ON "FSI" MODELS OPTIONAL ON "FS" MODELS SECTION "A"-"A" MODEL DIM. H FS 9 /8" FSI 9 /2" DIM. H2 2 /8" 2 /2" DIM. H3 5 /8" 5 /2" "A" REAR VIEW MOUNTING BRACKET SLOTS ALLOW FOR " VERTICAL ADJUSTMENT 5

DIMENSIONAL DATA Wall Mounted Units Models W and WI *With Top Discharge SEE PAGE 6 for other air flow arrangements. MAXIMUM RECESS DEPTH MODELS W060, W070, WI090, WI00 ONLY. 6 CAT0020

DIMENSIONAL DATA Recessed Wall Mounted Units Models RW and RWI SEE PAGE 6 for other air flow arrangements. SEE PAGE 9 for Wall Seal Kit. CAT00203 7

DIMENSIONAL DATA Ceiling Mounted Unit (Non Recessed Only) Model C SEE PAGE 6 for other air flow arrangements. MAXIMUM RECESS DEPTH MODELS C40, C50, C60, C80 ONLY. 8 CAT00202

DIMENSIONAL DATA Recessed Ceiling Unit Model RC SEE PAGE 6 for other air flow arrangements. SEE PAGE 9 for Wall Seal Kit. CAT00204 9

DIMENSIONAL DATA ACCESSORIES WALL SEAL CAT00206 20

DIMENSIONAL DATA ACCESSORIES DUCT COLLAR OUTLET AND DISCHARGE CAT00206 FRESH AIR INLET CAT00205 2

OPTIONAL FEATURES LOUVERED INLET GRILLE FOR MODEL "F" The optional louvered inlet grille provides a continuous closed floor line on the Model "F". It hinders build up of dust, papers or other materials found in the normal work area. This feature is standard with Model "FI". ARCHITECTURAL BAR GRILLE Architectural clear anodized aluminum bar grille is optional on all sizes. The rugged aluminum vanes provide a strong lineal appearance preferred in professional offices and other feature areas (may be painted to match cabinet unit heater color). In place of standard louvers. Is not to be used in place of option 7. OPTIONAL MANUAL OUTSIDE AIR DAMPER OPTIONAL MOTORIZED OUTSIDE AIR DAMPER OPTIONAL TAMPER RESISTANT FASTENER FOR ACCESS DOOR (OPTION ) OPTIONAL LEVELING LEGS 22

TECHNICAL DATA ALTITUDE FACTORS Approximate factors for convective heat value at varying altitudes Altitude Ferrous Units Copper Alum. Units Sea Level.000.000,000 ft..984.969 2,000 ft..968.938 3,000 ft..952.908 4,000 ft..936.878 5,000 ft..920.850 6,000 ft..904.822 7,000 ft..889.795 8,000 ft..874.768 9,000 ft..859.743 0,000 ft..844.78 5,000 ft..77.603 20,000 ft..703.502 Note: The heat output of standard heat distributing units is not affected enough to be considered in sizing the units, when theflow rate has been increased as shown at left. If not increased, apply appropriate heat transfer correction factor indicated. WIRING DIAGRAMS Standard Wall and Floor Units COIL CAPACITIES OF WATER Values shown below are decimal equivalent of a U.S. gallon Standard High Capacity Unit Size (One Row Coil) (Two Row Coil) 02 0.208 0.35 03 0.263 0.404 04 0.285 0.448 06 0.35 0.58 08 0.362 0.603 0 0.390 0.660 2 0.428 0.737 4 0.500 0.866 WATER IN OUNCES PER UNIT Example: If the unit size is 04 with standard coil, then multiply.285 x 28 ounces = 36.48 ounces CORRECTIONS WHEN USING GLYCOL SOLUTION IN SYSTEM Standard Ceiling Units Ethylene Propylene Glycol Glycol. Heat transfer 20% Solution.946*.982* @ 80 F, with 30% Solution.93*.96* no increase in 40% Solution.879*.934* flow rate 50% Solution.842*.902* 2. G.P.M. req d. 20 t 4%* 0%* @ 80 F, (no correction to pump curve) 3. Pump head req d. 23%* 23%* @ 80 F, with increase in G.P.M. 4. Freezing Point 50% by volume -37 F -28 F 40% -4 F -3 F 30% + 2 F + 4 F 20% +5 F +7 F *Compared To Water. 23

SPECIFICATIONS & WARRANTY* *STANDARD CABINET UNIT ONLY The contractor shall furnish and install Beacon-Morris Cabinet Unit Heaters as selected to meet or exceed job requirements. The Cabinet Unit Heaters will conform to the items listed below and be certified under CSA guidelines. CABINETS All cabinets will be constructed with 8 gauge electro galvanneal steel internal cabinets, side panels and top. The front panel shall be furnished in 6 gauge electro galvanneal steel. Adequate work area for installation of control valves or electrical equipment shall be provided on both sides of the internal cabinet. The cabinet shall be provided with a neutral eggshell baked enamel prime coat as standard. (Provided if not specified) Powder coated baked enamel, color selected from standard Color Chart. All cabinets shall be supplied with adjustable rear mounting brackets which will provide adjustment to correct alignment of the unit at installation to non square or out of true walls, joists, studs or surfaces. Adjustable leveling legs (two each base leg) are available when specified. RECESSED UNITS All recessed units shall be supplied with a "Wall Seal" assembly. This assembly shall provide protection to the wall or ceiling construction material. The "Wall Seal" shall be supplied in an eggshell baked enamel prime coat as standard. (When specified) Baked enamel colors may be selected from standard Color Chart. CEILING MOUNT OR RECESSED UNITS All "RC" units shall be supplied with a continuous hinged front panel. The continuous hinge shall provide full swing through 90. A safety chain shall be provided as standard to prevent the face panel from swinging fully open accidentally. This chain can be easily detached to allow full access for servicing. Speed control switch will be shipped with wiring diagram for installation where desired. FILTERS All filters supplied as standard shall be reusable aluminum media with a 69% arrestance level. Filters shall be slide in type which are locked into position with two cotter pins. FANS Fan wheels shall be centrifugal, forward curved, double width of electro galvanneal steel. Fan housings shall be of formed, galvanized sheet metal. MOTORS All motors shall have integral thermal protection and start at 78 per cent of rated voltage. All motors shall be of p.s.c. design and be capable of operating in high static conditions. All motors shall be factory run-tested and assembled in unit prior to shipping. ELECTRICAL All primary internal wiring shall be done at the factory and every unit shall be factory tested for reliability. FRESH AIR DAMPERS When desired specify either of the following:. Where noted 25% Manual Outside Air Dampers shall be provided. A manually operated damper quadrant shall provide from 0% to 25% outside air through the use of a single blade damper. 2. Where noted 25% Motorized Outside Air Dampers shall be provided. A synchronous motor (5/60/) interlocked with the blower shall automatically open the outside air damper when blower starts. The single blade damper shall be adjustable from 0% to 25% outside air. When the blower stops or there is a loss of power, the damper shall return to the closed position. A damper override switch shall be provided to prevent damper operation when desired. WARRANTY The products in this catalog are warranted by Beacon-Morris, to be free from defects in material and workmanship for a period of one () year from the date of shipment from Beacon's plant. Beacon's liability under this warranty is limited to replacing or repairing at our option, F.O.B. our plant any defective component or assembly returned to our factory prepaid and with proper return authorization document. All repairs or replacements are made subject to factory inspection. In the interest of product improvement, Beacon-Morris reserves the right to make changes without notification. Beacon/Morris 260 North Elm Street 7555 Tranmere Drive Westfield, MA 0085 Mississauga, Ontario L5S L4 Tel: (43) 562-5423 Tel: (905) 672-299 Fax: (43) 572-3764 Fax: (905) 672-2883 www.beacon-morris.com