instant hot water no waiting & no waste benefits Hot water recirculation solutions Astro hwr

Similar documents
ASTRO 2 SERIES HOT WATER RE-CIRCULATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

ASTRO 2 SERIES HOT WATER RE-CIRCULATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

Astro Express 2 - Hot Water Delivery System

Domestic Hot Water Systems and Plumbing Products

Astro 2 circulator models. Installation and operating instructions

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

The smart way to instant hot water comfort.

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

E.2 series high efficiency circulator. Installation and operating instructions

Taco 00 Series Cartridge Circulators

Condensing boiler plant (vp)

6800 Design Envelope Booster. Technical overview

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed

dualarm Vertical In-Line Pumps

NR-20DU. Keep this manual near this remote controller for future reference whenever maintenance or service is required.

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

ACT D MAND KONTROLS System FACTS AND QUESTIONS (FAQ)

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

Installation and operating instructions. E.2 Series high efficiency circulator

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

Domestic Hot Water Application manual

Indirect-Fired Water Heaters

Installation and Operating Instructions

Indirect-Fired Water Heaters

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

Indirect-Fired Water Heaters

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

ADMS. AERCO Digital Mixing Station. AERCO.com

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

THE INNOVATION LEADER IN HOT WATER RECIRCULATION

JH Series Installation

Packaged Semi-Instantaneous Steam Fired Water Heater

CAUTION. Installation Manual

TANKLESS PRODUCT GUIDE

Hydronic Mechanical Panels

opti-visor ultra-efficient chiller plant automation Typical specification

Sequence of operation

Automatic Temperature Controller (ATC)

TURBOMAX USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR

DigiTemp. Digital Water Tempering System. PVI.com

Honeywell Water Solutions. Thermostatic Mixing Valves

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Hot-Water Circulation

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1

Product Manual. Companion Water Heater. Maintenance Parts. Installation Startup. for WM97+ Gas-Fired Boilers

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

HL45, HL80 Thermostatic High-Low Valves

GRUNDFOS PLUMBING & HVAC PRODUCTS

Solar Indirect Water Heater

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

SECTION PLUMBING EQUIPMENT

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

TMV45 & TMV80 Standard Thermostatic Mixing Valves

2.A MANIFOLD SHUNTS MINI SHUNTS

Circuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.

"Best Practices in Modern Hydronic Heating - THE DETAILS

Allcan TM Installation Manual

SECTION WATER HEATERS

Semi-Instantaneous Indirect Fired Water Heater

energy-efficient Hot Water Never Looked So Good

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

Solar Thermal Planning Worksheet Date: / /

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

Solar Storage Tank with Electric Backup Instruction Manual

propanel Series Installation Manual

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions


Solar heating systems

Standard Assessment Procedure Instantaneous Waste Water Heat Recovery Systems Design Checklist for 'System A' Installation Configuration

SECTION SECTION DESIGN REQUIREMENTS

GOLD Plus 30/40/60/80

DUKE UNIVERSITY DESIGN GUIDELINES

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

DIGITAL HOT WATER SOLUTIONS

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Moon Visions Lighting

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

SECTION ELECTRIC WATER HEATERS

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

VERTICAL FAN COIL UNITS

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

SECTION DOMESTIC WATER PUMPS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS

Transcription:

Astro hwr Hot water recirculation solutions 37 CM solution outline file no: 10.13 date: september 017 supersedes: 10.13 date: june 016 instant hot water no waiting & no waste benefits 3 Complete packaged product Plug and play installation Covers a wide range of applications from 100 3500 sq ft

opportunities to add value Customers are looking for reliable hot water recirculation solutions that deliver instant comfort and adhere to industry codes. The Astro Hot Water Recirculation system from Armstrong includes everything contractors and building owners want: A complete, dependable solution Compliance with code requirements and minimized environmental impact Low installed cost Easy installation, with no call-backs required for adjustment choose your type The Astro Express system for homes or buildings where no dedicated recirculation lines are available Use hwr solutions where dedicated recirculation lines are used three-speed switch immediate value & lasting satisfaction The Astro Hot Water Recirculation (hwr) system from Armstrong is the perfect solution to help contactors build your installed base and add long-term satisfaction for your customers. It s a no hassle hwr system with great performance flexibility.

upgraded comfort & efficiency for owners for contractors The Astro hwr system eliminates the wasted water and the wait time, delivering hot water to the tap in 3 5 seconds. Looking beyond the luxury of instant hot water, the Astro hwr system helps home owners/ buildings owners with: Minimal inconvenience on installation Easy adjustment of settings Performance reliability based on a longproven product design and construction For contractors, the Astro hwr offers even more value: Simplified ordering Sizes to serve a wide range of home or buildings designs Easy installation with no requirement for specialized tools or materials how it works: hwr In normal operation, the Astro automatically starts recirculating water throughout the hot water distribution system whenever the timer enables activation. The timer can be set for one or more activation periods per day. An activation period consists of up to 96, 15-minute intervals. The timer includes manual on and off overrides to normal automatic operation. Some models are equipped with an Aquastat, intended for use on metallic piping. The Aquastat enables operation only when the sensed water temperature is below 85 f (5 c). Once activated, the circulator operates until either the water temperature reaches 105 f (41 c), or the current timed activation period ends. nd floor 1st floor cold water inlet basement dhw tank re-circulation pump timer & aquastat check valve legend cold water pipe domestic hot water pipe re-circulation hot water pipe

value- ba sed design choices Astro hwr systems offer a complete set of performance features including: Three different product versions 4/7 operation, pre-set timer for operation and pre-set timer plus aquastat (for temperature activation) 45 mounting of integrated timer front facing for easy access Compatibility with both tankless and tanked residential hot water solutions Plug-and-play product design fabricated as a complete, assembled package (timer, aquastat and circulator) with no requirement for assembly or internal wiring Performance that permits installation in applications with up to 50 ft piping runs from tank to outlet technical data Power connection: 6.0 ft (1.8 m) power cord, molded duplex plug with ground Environment: Indoor use only Max. working pressure: 150 psi (1034 kpa) Ambient temperature: 39 f (4 c) to 104 f (40 c) Max. water temperature: 30 f (110 c) Low temperature switchpoint: 85 f (9 c) ± 10% High temperature switchpoint: 105 f (40 c) ± 10% Clock/timer: 1-hour analog clock with am/pm indication Timer settings: Individual mechanical toggle for each 15 minute interval in the 4 hour cycle Manual override: Three position slide switch; on/auto/off * High/low temperature switchpoints are as presented on pipe surface with the Aquastst (ta models only) model selection model Astro 0ssu ta/t/lc Astro 5bs/ 5ssu ta/t/lc Astro 30ss/ ta/t/lc Astro 50ss/ ta/t/lc length of pipe from the dhw tank to the furthest fixture Up to 60 ft (18. m) 60 ft to 100 ft (18. m to 30.5 m) 100 ft to 150 ft (30.5 m to 45.7 m) 150 ft to 50 ft (45.7 m to 76. m) * Above table applies to hot water re-circulation systems in residential buildings with one kitchen and two bathrooms. For residential applications with more than two bathrooms, choose the next largest size of circulations.

Dimensions and weights model a b c d e f Astro sweat Astro 0ssu** union Astro 0ssu** flanged 5.0 0 (17) 5.9 8 (15) 6. 3 8 (16) Note: all dimensions are in inches (mm) 5.46 (139) 5.6 (143) 6.49 (165) 4. 59 (117) 4. 3 8 (111) 4. 5 (115).7 (69).7 (69).7 (69) 1.87 (48) 1.87 (48) 1.8 (46) 5.43 (138) 5.43 (138) 5.43 (138) f astro 30ss/50ss flanged e b d a c astro 5bs sweat astro 0ssu/5ssu union f e b f e b d d a a c c pump with 4-hour timer, aquastat and line cord model part no. connection size Astro 0ssu050s-ta* 1103b-140 Sweat ½" Astro 0ssu075s-ta* 1103b-141 Sweat ¾" Astro 5bs050s-ta 1103b-14 Sweat ½" Astro 5bs075s-ta 1103b-143 Sweat ¾" Astro 0ssu-ta 1103b-144 npsm union 1¼" Astro 5ssu-ta 1103b-145 npsm union 1¼" Astro 30ss-ta 1103b-148 -bolt flange Astro 50ss-ta 1103b-149 -bolt flange pump with 4-hour timer, and line cord model part no. connection size Astro 0ssu050s-t* 1103b-40 Sweat ½" Astro 0ssu075s-t* 1103b-41 Sweat ¾" Astro 5bs050s-t 1103b-4 Sweat ½" Astro 5bs075s-t 1103b-43 Sweat ¾" Astro 0ssu-t 1103b-44 npsm union 1¼" Astro 5ssu-t 1103b-45 npsm union 1¼ Astro 30ss-t 1103b-48 -bolt flange Astro 50ss-t 1103b-49 -bolt flange pump with line cord model part no. connection size Astro 0ssu050s-lc* 1103-340 Sweat ½" Astro 0ssu075s-lc* 1103-341 Sweat ¾" Astro 5bs050s-lc 1103-34 Sweat ½" Astro 5bs075s-lc 1103-343 Sweat ¾" Astro 0ssu-lc 1103-344 npsm union 1¼" Astro 5ssu-lc 1103-345 npsm union 1¼" Astro 30ss-lc 1103-348 -bolt flange Astro 50ss-lc 1103-349 -bolt flange *Union pump with sweat hardware kit.

how it works: astro express system The Astro Express System is designed for a pipe plumbing system (one hot and one cold) and to deliver the convenience and comfort of Hot Water as soon as you open the tap. The patented Astro Express Valve is thermostatically controlled and will allow cooled water in the hot water supply side to be pushed back down the cold water lines until hot water reaches the valve. The Valve requires no external power and is installed at the furthest fixture from the water heater, while the Astro Circulator is conveniently located near the water heater where electric power is readily available. The Astro Express System includes a timer (with multiple activation periods) so that maximum energy savings can be achieved by only running the recirculation loop at times when it is most likely needed. Armstrong Express Valve nd floor Armstrong Express Valve 1st floor Re-circulation pump Timer and aquastat dhw tank Cold water pipe Domestic hot water pipe Cold water inlet basement

accessories You can customize your installation with these components: timer old 8103-130 Kit includes box and timer Fits Astro Circulators made prior to 015 new 8103b-130 Kit includes replacement and timer For all Astro Circulators made in 015 or later astro express valve You can use up to five valves on one system for long branches off the primary distribution system 561100lf 001 Made from leadfree bronze and nsf 37 certified aquastat controls Mounts to copper pipe only part numbers model part number ½" Aquastat 11013-10 ¾" Aquastat 11013-11

Performance curves astro 5bs, 5ssu astro 0, 30, 50 head - feet 0 0.13 0.5 0.38 0.50 0.63 0.76 0.88 14 4.3 1 10 8 6 4 flow - l/s astro 5bs astro 5ssu 0 0 0 4 6 8 10 1 14 flow - usgpm 3.7 3.0 3 16.4 1 1 3 1.8 1. 0.6 head - metres head - feet 0 0.13 0.5 0.38 0.50 0.63 0.76 0.88 1.01 1.14 8 8.5 astro 50 4 7.3 astro 30 3 astro 0 0 6.1 1 flow - l/s 3 4.9 3.7 8.4 4 3 1 1 1 1. 0 0 0 4 6 8 10 1 14 16 18 flow - usgpm head - metres toronto +1 416 755 91 buffalo +1 716 693 8813 birmingham +44 (0) 8444 145 145 For more information, contact your Armstrong representative or visit us at: www.armstrongfluidtechnology.com/ ContactUs manchester +44 (0) 8444 145 145 bangalore +91 (0) 80 4906 3555 shanghai +86 (0) 1 537 0909 são paulo +55 11 4781 5500 armstrong fluid technology established 1934 armstrongfluidtechnology.com tm