Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Similar documents
RIG RAT III. Wireless Multi-Point Gas Detection System. The Stand-Alone Solution

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Toxic Gas Detection. Model F12. Toxic Gas Detection

GasAlertMicroClip X3 Specifications

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ALTAIR 5X Multigas Detector Product Specification

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

SIL 2. Ultima X Series Gas Monitors CERTIFIED

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Model D12. Digital Gas Transmitter

Two-Channel Gas Controller

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Rig Rat III Detector. Wireless Multi-Point Gas Detection System. User Manual

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Sieger Apex. Flexibility that meets your requirements

Monitores Personales. Personal Monitor

IGD.CO.UK

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Warranty Registration

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Frequently Asked Questions

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

OLC(T) 100 FIXED GAS DETECTOR

APPLICATION DATA SHEET

Equipment. Model R002. Description. SF6 leak detector

3M Oldham OLCT 100. Description. Fixed Gas Detector

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Industrial Grade Gas Detection

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Industrial Grade Gas Detection

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

SAFESITE Multi-Threat Detection System

incontrol Systems Inc. Flame and Gas Detection

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

The Art of Gas Detection

RAE Systems Systems. User Presentation. October Protection Through Detection

Xgard. Fixed detectors For flammable, toxic or oxygen gases

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Micro III (Models G203, G203S, and G213) Operation Manual

MICRO III (G202 / G202s / G212) Single Gas Detector

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Combustible Gas Detection and Control System

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

FX-SMT Series INSTRUCTION MANUAL P/N THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

BM25 and BM25 Wireless

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

GAS DETECTOR ST400EC PART.NO

Gas Detection. Honeywell BW Solo. The next generation in portable single gas detection.

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Inc Series Digital Gas Detector/Controller. Operation Manual

Oxygen (O2) Single-Point Gas Detection System

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

G-TECTA TM. Portable Gas Detection Instruments

T82. Instruction Manual. Single Gas Monitor GUARANTEED. FOR LIFE. P/N REV 0 PRINTED ,000 Specifications Subject to Change

Hazardous Gas Detection System. [ for Homeland Security ]

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Stand Alone DYNAGARD SP Operation Manual

ALTAIR 5X Multigas Detector

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

GAS DETECTION International Gas Detectors CH4 NO

Toxic Smarter Transmitter Instruction Manual

VENTIS PRO SERIES. Product Guide

Industrial Grade Gas Detection Detecting The Difference

Model D12-IR. Digital Gas Transmitter...

User Manual. Single Gas Detector

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector.

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

ESD3000 ESD200 Combustible / Toxic Gas Detector

GLD-30 Gas Leak Detector

Pioneer-R16 Gas Monitor Operator s Manual

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

MICRO IV. Operation Manual. Single Gas Detector

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

ULTIMA X5000. MSAX5000.com

For the Safety of Your

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

M2 Transmitter Operator s Manual

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

ESD500. ESD500 Combustible / Toxic Gas Detector

(Vendor Signature) By Mail: Mark sealed proposal with Bid/Proposal No.2014'33' Vendor Contact I nformation :

FIXED POINT SINGLE OR DUAL GAS MONITOR WITH DUAL ANALOG OUTPUTS

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

An easy and flexible way to do gas detection.

Carbon Monoxide CO Transmitter ADT-X3-1110

Transcription:

Introduction United Safety applies the detection system as a multi-point monitoring for toxic gases, combustibles and oxygen hazards. Self-powered and solar-capable, the features unequaled versatility, with an extensive range of field configurations. With realtime, two-way data transmission and remote sensing capabilities, the represents the new generation of stand-alone system technology. Key Benefits is completely modular in design, with plug in ports for all system components and field interfaces. Microprocessor based operation and advanced sensor technology ensure reliability and performance. Cost effectiveness is a hallmark of the. Trenching and cabling costs are eliminated through wireless, two way digital RF data transmission. Maintenance free combustible sensors reduce the need for costly upkeep requirements. The standard controller allows the simultaneous display of readings and alarm state messages for up to eight remotely located sensors for optimal control. Two-way real-time communication with system elements located up to 1.8 miles (3 km) away.

Key Features Simple push-button interface for automatic calibration and setup choices. Signal Transmission: Digital, 2.4 GHz, license-free ISM band radio frequency (RF) transceiver provides two-way, real-time communication with the controller located up to 1.8 mi/3 km away. Encoded digital signal is RFI protected. Standard package uses a 200 mw radio. A 10 mw radio is available. Alphanumeric Display: Two continuous LCD gas readouts show local real-time concentrations present for, % LEL and/or O 2 % by volume. Security Keylock: Protects access to operations bay. Rugged and Durable: Stainless steel enclosure with mounting flanges and carrying handle. Audible Alarm: Built-in 85 db alarm. Power Port: Battery powered, solar and line-capable. Flashing Visual Alarms: Bright alarm light advises alarm levels, type and sensors affected. Two Sensor Ports: Install one or two sensors as needed. Two Option Ports: Plug-in ports accept remote alarms, relays, etc. Plug-in Sensor Cables: Place sensor at the optimal location, up to 250 ft / 76 m away from the detector. New Zero-maintenance Remote Sensors: Gas specific color coding. No sensor replacement required, no downtime. Intrinsically safe, combustible (% LEL), toxic gases and oxygen plug-in sensors.

Rugged and Durable: Rugged, stainless steel enclosure. Optional: Plug-in RS-485/MODBUS module. Alphanumeric Display: Real-time readings for all detectors and sensors. Channel alarm LCD indicator flashes and latches to indicate alarm condition. Channel Activation: Individual enable/disable channel control switches. Each channel receives unique digitally coded alarm signals from the detector. Audible: Built-in audible (85 db) and visual alarms. System Reset: Alarm acknowledgement/ alarm reset switch. Security Locks: Heavy duty stainless steel latches. Security ON/OFF Keylock: Protects access to operations bay. Two Option Ports: Two plug-in option ports: one for alarm bar and one for discrete relay option (future expansion). Power Port: Operate controller via line power, or connect to external emergency power supply. Battery backup with auto recharge. Status LED: Advises power status: Green - A/C Red - Battery.

Specifications Description System Gas Detector Alarms LCD Displays Controls Ports Modular Multi-Point Wireless Gas Detection System Signal Transmission: 2.4 GHz licence free, ISM band spreadspectrum RF transceiver. User-settable discrete codes. Distance: Up to 1.8 mi / 3 km, depending upon antenna configuration Independent detector with radio transceiver Power: 12 V, 3.4 amp hr. rechargeable battery Battery Life: Up to 30 days, without active recharge (dependent on sensors) Recharge: Via solar power; line (24 VDC direct, 110/230 VAC) or bench chargers Clearly advises alarm levels both audibly and visually Visual Alarms: Large, red flashing light LCD: Alarm level present, sensor affected and alarm type Audible Alarm: Oscillating 85 db at 3 ft / 1 m (typical) Gas Alarm Levels: Two per sensor (LOW, HIGH) with field-settable setpoints Other Alarms: Fault advises missing sensor, damaged cable and/or low battery alarm Two continuous, alphanumeric gas readouts and status displays (gas or %). Simultaneously and continuously displays gas concentration(s) present, and status indicators advise (transmitter status, battery level, sensor fault, alarm level setpoints). Power ON/OFF Transmitter (XMTR) DISABLE Transmission TEST Two sensor ports; two option ports; charger port; TNC antenna port Security Keylock access to control panel General Specifications 14 gauge stainless steel, NEMA 4, RFI/EMI shielded Size: 8.46 x 11.26 x 4.53 in / 21.49 x 28.6 x 11.51 cm Weight: 11 lb 6 oz / 5.15 kg Remote interchangeable plug-in units Type: combustibles, catalytic bead, toxics and oxygen, electrochemical Temperature Range: combustibles -40 to +50 C / -40 to +122 F Hydrogen Sulphide: -40 to +50 C / -40 to +122 F NH 3, Cl 2, HCl, ClO 2, O 3 : -20 to +40 C / -4 to +104 F other toxics and oxygen: -20 to +50 C / -4 to +122 F Physical: Toxic/O 2, stainless steel, NEMA 4 Combustible: maintenance-free, encapsulated, NEMA 4 Warranty: 2 years, including all sensors (except NH3 and PH3-1 year) Gases Monitored: Change the gas monitored and/or the measuring range at any time. Combustible gases/vapors Oxygen Toxics: Ammonia, Carbon Monoxide, Chlorine, Dioxide, Ethanol, Ethylene Oxide, Hydrogen, Hydrogen Chloride, Hydrogen Cyanide, Hydrogen Sulphide, Nitric Oxide, Nitrogen Dioxide, Ozone, Phosgene, Phosphine, Sulfur Dioxide MRK-COR-SP-250-EN-CAN-14-2

Specifications Description Combustibles (encapsulated) Hydrogen Sulfide LCD Increments 1% LEL Standard Measuring Ranges Available Units #1 #2 #3 #4 #5 #6 % 0-50 0-500 0-20 Sulfur Dioxide 0-20 0-10 Ammonia 0-50 Carbon Monoxide 0-500 Chlorine 0-5.0 0-10.0 Oxygen 0.1% %v/v 0-25.0% 0-30.0% Other Gases Contact BW Technologies Controllers Standard controller (RR-3C04) for up to 4 detectors Signal Output: MODBUS (RS-485) -optional Signal Input: Discretely coded radio signals from each detector Power: 110 VAC; 230 VAC (selectable) Battery Backup: Two 12 VDC rechargeable batteries (normal operation: up to 4 hrs.) Alarms Visual: LCD displays alarm level present, sensor affected and alarm type Audible: 85 db at 3 ft / 1 m (typical) Alarm Relay Outputs Four (4) SPDT relays; 10 amp at 110 VAC/24 VDC, 8 amp at 230 VAC Indicators LEDs (four / channel): 2 alarm indicators, 1 fault, 1 channel enable Controls One ON/OFF switch; one ENABLE/DISABLE switch per channel and one momentary reset/test switch Ports Antenna port: TNC (reverse polarity) Alarm bar port: 12 VDC output per channel External relay port: Alarm specific relay option Common relay port: Low, high and fault (latching configurable) Enclosure: Self-contained 14 gauge stainless steel with mounting flanges, NEMA/Type 4 Physical: 14.95 x 11.16 x 5.15 in/ 37.97 x 28.35 x 13.08 cm; weight 21 lb/ 9.53 kg Power Independence The following sensor configuration lists the duration of the internal, rechargeable battery life (per charge): 2 toxic sensors: Up to 30 days 1 toxic, 1 LEL: Up to 5 days 2 LEL sensors: Up to 3 days Note: Battery life will vary depending on transmission interval and temperature. MRK-COR-SP-250-EN-CAN-14-2