... with Knowledge Solutions Lightning Protection Standards

Similar documents
P-16 ENGINEER NO. DATE DESCRIPTION 1 01/19/2016 FOR CONSTRUCTION 2 03/11/2016 REVISION # 2 DRAWN BY: CHECKED BY: DATE: SCALE: DRAWING NUMBER

6. ENGINEERING SYSTEMS REQUIREMENTS H50 WATERFRONT UTILITIES

IFGC-2012 AMENDED IFGC-2015 IFGC-2018 CHAPTER 1 SCOPE AND

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

SOUTH AFRICAN NATIONAL STANDARD

Dear Concessionaire,

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Bonding Requirements For Gas Piping Systems

Fire is No Accident Fire is No Accident It can be prevented.

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

Electrical Tech Note 107

Electrical Grounding For Oil and Gas Applications

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

Builders Risk - Fire Prevention Inspection Checklist

NFPA 54 UPDATE. Paul Cabot American Gas Association

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

Electrical Protection of CSST Gas Piping Systems. Bob Torbin, PE Omega Flex, Inc.

CADDY CORPORATION. Utility Distribution Systems

On-Call General Contractor Specifications University of Maryland College Park June 2013

2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016)

ORDINANCE NO

EVALUATION RISK ACCORDING UNE :2 / UNE 21186:2011 / NFC :2011 SELECTION OF PROTECTIVE MEASURES AGAINST LIGHTNING

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

IAS Accreditation Number Applied Research Laboratories of South Florida, LLC 5371 Northwest 161st Street Miami, Florida 33014

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

WARNING CAUTION. Approval Marks. Protection Class I TECHNICAL DATA. CCA certified

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL XP DRUM KIT PATENT PENDING UTILITY 35 USC 111(A)

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14

RISKTOPICS. Photovoltaic systems

SECTION GAS-FIRED RADIANT HEATERS

Document Number: HSP Prepared by: Jim Landry Manager Approval: Hillary Garner HEALTH AND SAFETY PROGRAM HSP 506 FIRE PREVENTION PLAN

S U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: ARTICLE I ELECTRICAL CODE

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

Should you have further questions, please feel free to contact the Fire Prevention Branch.

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes

SECTION WET-PIPE SPRINKLER SYSTEMS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

B. Section Identification for Fire Suppression Piping and Equipment.

and SHUTTERS Made to Work. Built to Last.

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

HEAT & SMOKE VENT INSPECTION AND MAINTENANCE PACKET

Yellow Corrugated Stainless Steel Tubing (CSST) Questions and Considerations

*************************************************************************** SECTION D50 ELECTRICAL 02/18

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Installation Instructions Remote Blowers

CHIMNEYS AND VENTS CHAPTER 8

TABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater

SECTION DUCTWORK

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

SECTION EXTERIOR LIGHTING

Teflon Rotary Drum Pump

Part#: 26B113 HEAVY DUTY CAST IRON ROTARY DRUM PUMP

SECTION ISOLATED POWER SYSTEMS

ARGENTA INOX. IP66 Stainless steel wallmounting. ARGENTA INOX Technical Specifications (Stainless steel) ARGENTA INOX Certifications (Stainless steel)

SECTION ELECTRICAL GENERAL PROVISIONS

INTERNATIONAL STANDARD

UNIFIED FACILITIES CRITERIA (UFC)

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

DOD FUELS LABORATORY STANDARDS UFC

PART 2. Basic Code Requirements - Semiconductor & Microelectronic Facilities using HPM s

nimbus new ESE LIGHTNING ROD NF C :2011 standard Designed and tested in full accordance with the new

Commercialon Premium Adhesives and Sealers

Revitalize Building Mechanical Systems (4619)

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Installation Instructions

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Burn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:

ARTICLE 25. FUEL GAS CODE

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

Network Speed Dome Installation Manual

SECTION PLUMBING EQUIPMENT

NFPA 96, 2017 REVIEW SUMMARY

Installation Instructions

TABLE OF CONTENTS. Part I Administrative... 1

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

UNIFIED FACILITIES GUIDE SPECIFICATIONS

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Installation Instructions

FMP-DVS. Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions

The Residences at Christina Landing Wilmington, DE

Transcription:

Lightning Protection Standards

Richard Bouchard Employed With UL for 24 Years Technical Advisor for UL s Lightning Protection Services Member of NFPA 780 Technical Panel Certification for Residential Building Inspector to the International Building Code for Single and Multi Family Dwellings Pending Slide 2

Objectives Standards Actively Used Design and Inspection NFPA 780 UL 96A UFC 3-570-01 AFMAN 91-201 NAVSEA OP-5, Vol. 1 DA Pamphlet 385-64 First Three Used for Ordinary Buildings Last Three Referenced for Ordnance / Explosive Facilities Slide 3

Standard Used for System Design NFPA 780 UFC 3-570-01 Slide 4

Standard Used for System Inspection UL 96A Slide 5

NFPA 780 Relationship Between the Standards Base Document Used by UFC 3-570-01 & UL96A UL96A Designed to Meet All the Min Requirements UFC 3-570-01 Provides Guidance for Areas Not Covered in NFPA 780 UL96A Intended As an Inspection Standard Defined Requirements Less Interpretations. Slide 6

Relationship Between the Standards UFC 3-570-01 Unified Basic Requirements Between Service Branches Expansion of Requirements for Special Types of Structures Guideline Requirements for Ordnance / Explosive Facilities Slide 7

Major Differences Between the Standards UFC 3-570-01 & NFPA 780 Section 5-3 refers to NFPA 780 Appendix H for risk assessment to identify structures not needing coverage. 5-4.1 Capped air terminals are not permitted. 5-4.1.2 Air Terminals gives specific distances for exhausting hazardous vapors Air terminals installed on rubber (EPDM) type roofs Slide 8

Major Differences Between the Standards UFC 3-570-01 & NFPA 780 5-4.1.3 Conductors. Bolted Connections Are Not Allowed on the Roof and Down Conductors. Roof and Down Conductors Shall Be Exothermically Welded or Shall Use High Compression Fittings There Are No Listed High Compression Fittings Listed by UL for This Application. 5-4.2 Mast System. The down conductors need to be protected from grade level to a point 3 m (10ft) above grade. Slide 9

Major Differences Between the Standards UFC 3-570-01 & NFPA 780 5-4.2.7 Joint Design. Not covered in NFPA 780 5-4.2.8 Joint Test. Not covered in NFPA 780 5-4.4 Faraday Shield System. Not covered in NFPA 780 5-5 NONCONVENTIONAL SYSTEMS. Dissipation Arrays and Those Using Early Streamer Emission Air Terminals Are Not Acceptable and Are Not Be Used. Slide 10

Major Differences Between the Standards UFC 3-570-01 & NFPA 780 5-6.2 Bonding Installation Guidelines For Design And Construction. Basic Requirements for Bonding of LPS Are in AFI 32-1065 and NFPA 780. 5-7.1 Ground Resistance. 5-7.2 Not Covered in NFPA 780 With a Specific Value but Techniques. Plate Electrodes Is Discouraged Slide 11

Major Differences Between the Standards UFC 3-570-01 & NFPA 780 5-10.2 Reinforced Concrete Buildings. Reinforcement Steel May Be Used for Down Conductors, in Conformance With NFPA 780. This Is Not Allowed in NFPA 780 5-10.3 Steel Frame Building With Non-conducting Roof and Sides. At Least One Steel Column Must Be Grounded at Each Corner of the Building. 5-10.4 Through 5-10.6 Installation Techniques Not Covered in NFPA 780 Slide 12

Major Differences Between the Standards UFC 3-570-01 & NFPA 780 5-10.9 Post Tensioning Systems. The Post Tension Rods Shall Not Be Used As a Path for Lightning to Ground. 5-10.10 Through 5-10.20 These Cover Special Types of Ordinary Structures Slide 13

Questions Slide 14

Thank You for Attending