Indoor Air Handlers with Compressors MVS and MVW

Similar documents
Self-Contained Reverse Cycle Air Conditioners

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Self-Contained & Split System Reverse Cycle Air Conditioners SAB Self-Contained Units, CAB Condensers and DEAH Air Handlers

General Description. Operation

Reverse Cycle Chiller Models CHA24, 36, 48 & 60

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

Wall Mounted Air Conditioners with Gas Heat Models AVGA

General Description. Safety Listed

Hazardous Location Certified

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

General Description. Safety Listed

10EER 7.5 Ton Vertical Wall Mount Air Conditioners Model AVHDA90 (Dual Compressor)

ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

MAC N-407 Air-Cooled Chiller

Installation and Operation Manual

MACH N-407 Heat Pump Air-Cooled Chiller

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

2 to 5 Ton Vertical Packaged Wall Mount Heat Pumps

9-11+ EER 2-5 Ton Vertical Packaged Wall Mount Heat Pumps

Commercial High-Efficiency Condensing Units

MAC-120HE-03 Air-Cooled Chiller

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Condensing Units & Air Handlers

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

2 shp 13 lc 1 36 t - 1 a

TECHNICAL SPECIFICATIONS

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

PRODUCT DATA SHEET. General Description

9-11+ EER 1-6 Ton Vertical Packaged Wall Mount Air Conditioners

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

MERIT SERIES Up Flow / Horizontal

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

WCH5**4. Product Specifications

MERIT Series R-410A - Upflow / Horizontal

Advance Release September 2009

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

CommStat 4 Controller

PRODUCT SPECIFICATIONS

GreenPac and GreenPac HGR Vertical Wall Mount Heat Pumps and Air Conditioners. Manufactured By:

MERIT Series R-410A - Upflow / Horizontal

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Commercial High-Efficiency Condensing Units

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

R4H4. Product Specifications

C13-Series Engineering Guide

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

PAJ3. Product Specifications

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

Portable Vertical Air-Conditioning and Heating Systems

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

GREEN REFRIGERANT R-410A

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

Product Guide. Wallmount. Air Conditioners & Heat Pumps

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

R4H4. Product Specifications

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL SPECIFICATIONS

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

TECHNICAL SPECIFICATIONS

GUIDE SPECIFICATIONS AQUARIUS ii

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

Installation & Operation Manual 9-11 EER Vertical Wall-Mount Air Conditioners

13 SEER CONDENSING UNITS

N4H4. Product Specifications

TECHNICAL SPECIFICATIONS

Owner s and Installation Manual

TECHNICAL SPECIFICATIONS

Transcription:

Indoor Air Handlers with Compressors MVS60-90-120-144 and MVW60-90-120-144 General Description The Marvair Marine self-contained water and air cooled air conditioners are designed for both new installations and for replacement of older, less efficient units in marine applications. The air conditioners are available in cooling capacities of 5, 7½, 10 and 12 tons (60,000, 90,000, 120,000 & 144,000 BTUH s) and are controlled by a conventional 24 VDC wall mounted, HVAC type thermostat. The vertical configuration minimizes floor space and blends into a variety of working environments. The cool, dry air can be discharged directly into the room or ducted into adjacent rooms. All service and maintenance is performed from the front or side of the unit- no need to move the unit for service or maintenance. To ensure years of dependable performance, all components are housed in a superior corrosion resistant steel cabinet. The galvaneal steel is bonderized and followed by a heat cured enamel neutral gray finish. Air Cooled Units The MVS air cooled units have an indoor air mover, coil, compressor and controls. A remote condenser (not provided by Marvair) connects to the MVS unit with field installed refrigerant lines. The units are shipped with a dry nitrogen charge and may be used with either R-22 or R-407c refrigerant. Water Cooled Units The MVW water cooled air conditioners are packaged units shipped from the factory with R-407c refrigerant and an internal condenser and ready to run. The coaxial tube-in-tube condenser is constructed of corrosion resistant cupronickel water tubing and copper refrigerant tubing for use in either fresh or sea water. High Efficiency Model MVS144 The latest in scroll compressor technology combine with a lanced fin and rifled tube evaporator coil for low power consumption. The 10 and 12 ton air conditioners have two compressors, allowing for staged operation. The dual compressors can be programmed to start sequentially, minimizing start-up amps. In addition to better humidity control and comfort, the dual compressors provide back-up protection, increased operating efficiencies and energy savings. The MVW water source units use a heat exchanger constructed of an eight volute, multi-lead cupronickel inner tubing. The convolutions increase transfer and refrigerant turbulence, further enhancing the thermal performance while inhibiting the accumulation of deposits in the water tubing. MVS/MVW PDS rev.3 10/2011 1 MVS/MVW PDS 10/2011

Ease of installation and maintenance The units are pre-piped and wired, minimizing installation time. The readily accessible control center contains all the control components. On the MVS (air cooled) units, a 24 VAC relay is included for the condenser fans. Two condensate drain locations allow the installer to best match the location of the drain to the condensate openings. A secondary drain is standard, provides protection against a clogged primary drain and may eliminate the requirement of a drain pan under the unit. Rotolock valves on the compressor permit the compressor to be removed and replaced without brazing or recharging the system. Shut-off isolation valves with flare connections on the discharge and liquid lines on air source units facilitate the connection of the remote condenser. Washable return air filters are conveniently located behind the return air grille. Engineered for Reliability The air conditioners are designed for years of dependable operation. High and low pressure switches with a lock out relay protect the compressors under abnormal operating conditions. A three minute delay on make safeguards the compressors from destructive short cycling. The evaporator coils have a baked polyester coating rated to 1,000 hours salt spray test. Electronic Control Board The internal control board in the air conditioners simplifies wiring, consolidates several of the electrical functions onto one device and improves the reliability of the air conditioner. In addition, the control board has LED s that indicate operational status and fault conditions. COLOR TYPE STATUS DESCRIPTION Green Power Constant On 24 VAC power has been applied Red Status Constant On Modes of Operation Normal Operation 1 Blink High Pressure Switch has opened twice 2 Blinks Low Pressure Switch has opened twice 3 Blinks Freeze sensor (optional) indoor coil temperature is below 35 F (1 C) Normal Start-up: On a call for cooling, and the with the high pressure switch closed, the cooling system (compressor, indoor blower motor and outdoor fan motor) will be energized. (Note: See the Delay on Make feature. Outdoor fan motor on air source units only). The cooling system will remain energized during the three minute low pressure switch bypass cycle. If the low pressure is closed, the cooling system will continue to operate after the three-minute bypass. If the low pressure switch is open after the three minute bypass, the cooling system will be de-energized. Lockout Mode: If either the high or low pressure switch opens twice on the same call for cooling, the control board enters into the lockout mode. In the lockout mode, the compressor is turned off, the alarm output is energized and the status LED s will blink to indicate which fault has occurred. If there is a call for air flow, the indoor blower will remain energized. When the lockout condition has cleared, the unit will reset if the demand of the thermostat is removed or when power is reset. The MVS and MVW air conditioners are factory wired for normally open contacts. The user can now have normally closed contacts by moving a wire on the control board. Delay on Make: On initial power up or on resumption of power, the air conditioner will wait.03 to 10 minutes (field adjustable) from a call for cooling before allowing the contactor to energize. Built in compliance with UL standards The MVS and MVW air conditioners are built in compliance with UL standard 1995, 2nd edition and CAN/CSA C22, No. 236-5, 2nd edition. The MVS and MVW air conditioners are marine units and are not intended for use in residential applications. MVS/MVW PDS 10/2011 2

Field Installed Accessories Thermostat: To control the 10 and 12 ton air conditioners with dual compressors, we recommend the Marvair 50107 digital thermostat. This thermostat is designed for control of 2-stage air conditioners and is 7 day programmable. The thermostat allows for either continuous fan or fan operation only when the compressor is operating. It has status LED s, a backlit display and nonvolatile program memory. For air conditioners with a single compressor (the 5 and 7½ ton units) we recommend the Marvair 50123 digital thermostat. Model Identification AC Refrigerant N = Nitrogen charge C = R-407c MVS = Marine Vertical Split (air source) MVW = Marine Vertical Water (water source) Nominal Cooling Capacity (BTUH) 60 = 60,000 90 = 90,000 120 = 120,000 144 = 144,000 Air Conditioner Power Supply C = 208-230V, 3ø, 60Hz D = 460V, 3ø, 60Hz Cabinet Color 216 = Gray Cabinet (standard) 116 = Beige Cabinet (optional) Nominal Cooling Capacity Model Nominal Cooling (BTUH) MVS/MVW60 60,000 MVS/MVW90 90,000 MVS/MVW120 120,000 MVS/MVW144 144,000 Electrical Characteristics - MVSxxxAC Indoor Air Handlers with Compressors (Air cooled) MODEL COMPRESSOR INDOOR BLOWER MOTOR Type Qty VOLTS-HZ-PH RLA 1 LRA 2 Qty VOLTS-HZ-PH RPM 3 FLA 4 HP 5 MVS60ACC Scroll 1 200/230-60-3 17.3 123.0 1 230/60/1 1500 4.3 3/4 MVS90ACC Scroll 1 200/230-60-3 18.6 156.0 2 208-230/60/1 1075 4.8 3/4 MVS120ACC Scroll 2 200/230-60-3 17.3 123.0 2 208-230/60/1 1075 7.2 1 MVS144ACC Scroll 1 200/230-60-3 17.3 123.0 2 208-230/60/1 1075 7.2 1 Scroll 1 200/230-60-3 18.6 156.0 MVS60ACD Scroll 1 460-60-3 8.2 62.0 1 230/60/1 1500 4.3 3/4 MVS90ACD Scroll 1 460-60-3 9.0 75.0 2 208-230/60/1 1075 4.8 3/4 MVS120ACD Scroll 2 460-60-3 8.2 62.0 2 208-230/60/1 1075 7.2 1 MVS144ACD Scroll 1 460-60-3 8.2 62.0 Scroll 1 460-60-3 9.0 75.0 2 208-230/60/1 1075 7.2 1 1 RLA = Rated Load Amps 2 LRA = Locked Rotor Amps 3 RPM = Revolutions per Minute 4 FLA = Full Load Amps 5 HP = Horse Power All 460 v. units have a step down transformer for 230v. motors. This chart should only be used as a guideline for estimating conductor size and overcurrent protection. For the requirements of specific units, always refer to the data label on the unit. 3 MVS/MVW PDS 10/2011

Summary Ratings (Wire Sizing) Amps - MVSxxxAC Indoor Air Handlers with Compressors (Air cooled) MODEL CIRCUIT #1 CIRCUIT #2 MCA MFS MCA MFS MVS60ACC 25.9 40 n/a n/a MVS90ACC 32.9 50 n/a n/a MVS120ACC 28.8 45 28.8 45 MVS144ACC 30.5 45 28.8 45 MVS60ACD 12.4 20 n/a n/a MVS90ACD 16.1 25 n/a n/a MVS120ACD 13.9 20 13.9 20 MVS144ACD 14.9 20 13.9 20 MCA = Minimum Circuit Ampacity MFS = Maximum Fuse or HACR circuit breaker. MFS & MCA calculated at 240v. For 460v. models ( D models), MCA & MFS calculated at 460v. All 460 v. units have a step down transformer for 230v. motors. This chart should only be used as a guideline for estimating conductor size and overcurrent protection. For the requirements of specific units, always refer to the data label on the unit. Electrical Characteristics - MVWxxxAC (Water cooled air conditioners) MODEL COMPRESSOR INDOOR BLOWER MOTOR Type Qty VOLTS-HZ-PH RLA 1 LRA 2 Qty VOLTS-HZ-PH RPM 3 FLA 4 HP 5 MVW60ACC Scroll 1 200/230-60-3 17.3 123.0 1 230/60/1 1500 4.3 3/4 MVW90ACC Scroll 1 200/230-60-3 18.6 156.0 2 208-230/60/1 1075 4.8 3/4 MVW120ACC Scroll 2 200/230-60-3 17.3 123.0 2 208-230/60/1 1075 7.2 1 MVW144ACC Scroll 1 200/230-60-3 17.3 123.0 2 208-230/60/1 1075 7.2 1 Scroll 1 200/230-60-3 18.6 156.0 MVW60ACD Scroll 1 460-60-3 8.2 62.0 1 230/60/1 1500 4.3 3/4 MVW90ACD Scroll 1 460-60-3 9.0 75.0 2 208-230/60/1 1075 4.8 3/4 MVW120ACD Scroll 2 460-60-3 8.2 62.0 2 208-230/60/1 1075 7.2 1 MVW144ACD Scroll 1 460-60-3 8.2 62.0 Scroll 1 460-60-3 9.0 75.0 2 208-230/60/1 1075 7.2 1 1 RLA = Rated Load Amps 2 LRA = Locked Rotor Amps 3 RPM = Revolutions per Minute 4 FLA = Full Load Amps 5 HP = Horse Power All 460 v. units have a step down transformer for 230v. motors. This chart should only be used as a guideline for estimating conductor size and overcurrent protection. For the requirements of specific units, always refer to the data label on the unit. MVS/MVW PDS 10/2011 4

Summary Ratings (Wire Sizing) Amps - MVWxxxAC (Water cooled air conditioners) MODEL CIRCUIT #1 CIRCUIT #2 MCA MFS MCA MFS MVW60ACC 25.9 40 n/a n/a MVW90ACC 32.9 50 n/a n/a MVW120ACC 28.8 45 28.8 45 MVW144ACC 30.5 45 28.8 45 MVW60ACD 12.4 20 n/a n/a MVW90ACD 16.1 25 n/a n/a MVW120ACD 13.9 20 13.9 20 MVW144ACD 14.9 20 13.9 20 MCA = Minimum Circuit Ampacity MFS = Maximum Fuse or HACR circuit breaker. MFS & MCA calaculated at 240v. For 460v. models ( D models), MCA & MFS calculated at 460v. All 460 v. units have a step down transformer for 230v. motors. This chart should only be used as a guideline for estimating conductor size and overcurrent protection. For the requirements of specific units, always refer to the data label on the unit. Dimensional Drawings - MVx60 5 MVS/MVW PDS 10/2011

Dimensional Drawings - MVx90 MVS/MVW PDS 10/2011 6

Dimensional Drawings - MVx120/144 REFRIGERANT OR WATER LINE CONNECTION REFRIGERANT OR WATER LINE CONNECTION UNIT X MVS/MVW120 56 3/8 MVS/MVW144 63 1/2 REFRIGERANT OR WATER LINE CONNECTION REFRIGERANT OR WATER LINE CONNECTION 7 MVS/MVW PDS 10/2011

Notes Please consult the Marvair website at www.marvair.com for the latest product literature. Detailed dimensional data is available upon request. A complete warranty statement can be found in each product s Installation or Owner s manual, on the website or by contacting Marvair. As part of the Marvair Continuous improvement program, all specifications are subject to change without notice. P.O. Box 400 Cordele, Georgia 31010 156 Seedling Drive Cordele, Georgia 31015 Ph: 229-273-3636 Fax: 229-273-5154 Email: marvair@airxcel.com www.marvair.com MVS/MVW PDS 10/2011 8 Marvair Marine UK Unit 6 Benridge Park Holyrood Close Poole, Dorset BH17 7BD. +44 (0)1202 650700 www.marvair.co.uk Marvair, Division of AIRXCEL, Inc. 10/2011