Ex Mark:Ex d eb ⅡB T6 Gb

Similar documents
LED Explosion proof Por table light

LED Explosion proof Torch Light. Ex Marking:Ex ibⅡc T4 Gb Ex ib ⅢC T130 Db IP 68. KHJ-LED Explosion Proof Lighting

INTRINSICALLY SAFE LIGHTING RANGE

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

High bay LED lighting fixture

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Dräger Polytron 5700 IR Detection of flammable gases and vapours

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

BC9700 series High Power LED Explosion Proof Light

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Manual Power relay SR853

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

Electrical Installations Design, Selection, Erection and Inspection

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

LUXCOMFO TM LED Flood Light Datasheet

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

EVLPF Series Compact Fluorescent

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Certificate of Compliance

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

LED ECO PANEL.

OLUX LED IN-GROUND OSRAM. Datasheet

LED ECO PANEL.

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

INSTRUCTION MANUAL (ATEX / IECEx)

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

Urbanlite. We light your world IK08 IP

0118M Series. Vision For Future LED SURFACE MOUNTED PANEL LIGHT WITH SENSOR OPTION. High light efficiency Energy saving Long life

Fan Heaters Type VLEx

Applications. Standard Materials

Glacial. COB Inground

WARRANTY LED ECO PANEL.

XLFE-4/1. Borosilicate glass globe

Dräger Polytron 5720 IR Toxic Gas Detection

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

DESIGNED SPECIFICALLY FOR QUICK AND EASY WATERPROOF INSTALLATION.

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

D O M E S T I C LED. Lighting C O M M E R C I A L

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

DTS Light fittings for explosive atmospheres

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

LED ECO PANEL.

N2MVF Series Compact Fluorescent

Premium. Universal LED Vapor Tight T20G. Commercial lighting Industrial lighting Vapor tight light Linear High Bay Canopy

Operating Instructions

WARRANTY LED ECO PANEL.

100W High Bay. Pendant style High Bay with Premium Performance

Ex LED light fittings

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

LED ECO PANEL.

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

LED Tri-proof Light. LED Tri-proof Light SPEC. Microwave Motion Sensor. Option: Remote control. Suitable for a variety of scenes

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

OLC(T) 100 FIXED GAS DETECTOR

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

SOLUZIONI PER ATMOSFERA ESPLOSIVA

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Dräger Polytron 8700 IR Detection of flammable gases and vapors

ipanel LED Panel Light

CoreLine Waterproof the clear choice for LED

Explosion Proof Combination Signal db (A) / 5 Joule

ADVANCED HIGH CEILING Tetriss Series

manual addendum DELPHI Ex

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Transcription:

Swordfish Series ED Explosion proof Floodlight Ex Mark:Ex d eb ⅡB T6 Gb Ex tb ⅢC T80 Db KHJ-ED Explosion Proof ighting 1

INTRODUCTION Features and benefits 1.Energy saving. Reduce the number of luminaires you need, providing excellent efficacy-more light where you need it. 2.Anti-glare.reduces glare in applications where the user may have direct visual contact with the light source. 3.Shock- and vibration-resistant- tempered glass, reduces the risk of premature failure. 4.SEOU ED source. High efficacy lumen output and high CRI. 5.Driver module assembly -High efficiency ED drivers are designed to provide reliable operation in even the harshest environments. 6.Copper -Free Aluminum enclosure, can endure 10J impact. IP66, can be used in marine and wet locations-robust construction suitable for saltwater and corrosive applications. 7. Different installation methods. 8.Safety chain design. Prevent any fall-off. 9.High power factor,energy saving. 10.Ambient temperature from -20ºC to 55ºC. Applications: 1.Petroleum Industry, Petrochemical Industry, Metallurgical Industry, Power Generation Industry, Power Transmission Industry, Machine Manufacturing. etc. 2.Drilling platform, single point moorings, oil tanks, workover platform, production platform, field tank, manifold center, pumping station, gasoline station, transformer station, coating plant,warehouse.etc. Executive standard: IEC 60079-0:2007 IEC 60079-1:2007 IEC 60079-7:2006 EN 60079-0:2009 EN 60079-1:2007 EN 60079-7:2007 EN 60598-1:2008+A11:2009 EN 55015:2013 IEC 62321:2008 Division: ATEX Zone 1 & 21 and 2 & 22 Class Ⅰ Divison 1&2 Groups C D Class Ⅱ Divison 1 Groups E F G Class Ⅱ Divison 2 Groups F G Class Ⅲ Divison 1 Class Ⅲ Divison 2 12 Certifications & Ratings: Ex d eb ⅡB T6 Gb Ex tb ⅢC T80 Db ATEX Compliant IECEx Compliant ABS Compliant CE Compliant RoHS Compliant IP 66 Rated

CHARACTERISTIC DETAIS SEOU ED source,high efficacy and lumen output. Industrial aluminium alloy enclosure, high performance of anti- impact. Can endure 10J impact. Copper -Free Aluminum enclosure, anti-corrosion. Suitable for different application. ED clung to the enclosurewhich make heat dissipation fast.ower the junction Temp. Characteristic details 13

PERFORMANCE PARAMETER Product Definition Ex- K SF XX XX XX XX XX -U -E Type Brand Series Power Input voltage Size(mm) Candela CCT(K) Type Area Distribution Ex-Explosion SF-Swordfish AC-100~277V WM-2700~3300K Proof A- AC DC 24~48V NH-3700~4300K U-Update E-English K-KHJ 18-18W 36-36W 48-48W 56-56W 72-72W B- DC 10~30V CH-5400~7000K 600-600mm 1200-900mm H7V7-120 Electrical Parameter: Product type Rated input voltage(vac) Rated input voltage(vdc) Rated input current(a) Frequency (Hz) Ex-KSF18600 100~277 0.18~0.07 5060 Rated power (W) ED input current (ma) Ex-KSF18A600 24~48 24~48 0.77~0.38 18 60 Ex-KSF18B600 10~30 1.84~0.61 18 60 Ex-KSF36600 100~277 0.37~0.13 5060 36 60 >0.98 Ex-KSF36A600 24~48 24~48 1.53~0.77 36 60 Ex-KSF36B600 10~30 3.67~1.22 36 60 Ex-KSF48600 100~277 0.49~0.18 5060 48 60 >0.98 Ex-KSF48A600 24~48 24~48 2.04~1.02 48 60 Ex-KSF48B600 10~30 4.9~1.63 48 60 Ex-KSF361200 100~277 0.37~0.13 5060 36 60 >0.98 Ex-KSF36A1200 24~48 24~48 1.53~0.77 36 60 Ex-KSF36B1200 10~30 3.67~1.22 36 60 Ex-KSF481200 100~277 0.49~0.18 5060 48 60 >0.98 Ex-KSF48A1200 24~48 24~48 2.04~1.02 48 60 Ex-KSF48B1200 10~30 4.9~1.63 48 60 Ex-KSF561200 100~277 0.57~0.21 5060 56 65 >0.98 Ex-KSF56A1200 24~48 24~48 2.38~1.19 56 65 Ex-KSF56B1200 10~30 5.71~1.9 56 65 Ex-KSF721200 100~277 0.73~0.27 5060 72 60 >0.98 Ex-KSF72A1200 24~48 24~48 3.06~1.53 72 60 Ex-KSF72B1200 10~30 7.35~2.45 72 60 PF THD 18 60 >0.98 14

PERFORMANCE PARAMETER Performance Parameter Product type PN Color temp. CCT(K ) CRI uminous flux(lm) Beam angle( ) Ex-KSF18*600H7V7WM-U-E Warm white 2700~3300 80 1822 120 Ex-KSF18*600 Ex-KSF18*600H7V7NH-U-E Natural white 3700~4300 80 2277 120 Ex-KSF18*600H7V7CH-U-E Cool white 5400~7000 80 2277 120 Ex-KSF36*600H7V7WM-U-E Warm white 2700~3300 80 3640 120 Ex-KSF36*600 Ex-KSF36*600H7V7NH-U-E Natural white 3700~4300 80 4554 120 Ex-KSF36*600H7V7CH-U-E Cool white 5400~7000 80 4554 120 Ex-KSF48*600H7V7WM-U-E Warm white 2700~3300 80 4858 120 Ex-KSF48*600 Ex-KSF48*600H7V7NH-U-E Natural white 3700~4300 80 6072 120 Ex-KSF48*600H7V7CH-U-E Cool white 5400~7000 80 6072 120 Ex-KSF36*1200H7V7WM-U-E Warm white 2700~3300 80 3640 120 Ex-KSF36*1200 Ex-KSF36*1200H7V7NH-U-E Natural white 3700~4300 80 4554 120 Ex-KSF36*1200H7V7CH-U-E Cool white 5400~7000 80 4554 120 Ex-KSF48*1200H7V7WM-U-E Warm white 2700~3300 80 4858 120 Ex-KSF48*1200 Ex-KSF48*1200H7V7NH-U-E Natural white 3700~4300 80 6072 120 Ex-KSF48*1200H7V7CH-U-E Cool white 5400~7000 80 6072 120 Ex-KSF56*1200H7V7WM-U-E Warm white 2700~3300 80 5667 120 Ex-KSF56*1200 Ex-KSF56*1200H7V7NH-U-E Natural white 3700~4300 80 7084 120 Ex-KSF56*1200H7V7CH-U-E Cool white 5400~7000 80 7084 120 Ex-KSF72*1200H7V7WM-U-E Warm white 2700~3300 80 7286 120 Ex-KSF72*1200 Ex-KSF72*1200H7V7NH-U-E Natural white 3700~4300 80 9108 120 Other parameter Ex-KSF72*1200H7V7CH-U-E Cool white 5400~7000 80 9108 120 Remarks: *Stands for Rated input voltage, including Default -AC-100~277V,A-ACDC 24~48V,B-DC 10~30V. Product type Size(mm) Weight (Kg) Ambient temp ( ) Max. surface temp.(test in 25 ) Temp.classification IP Code Insulation Ex-KSF18600*-U 600*136*85 6.4-20~+55 33 T6 IP66 Ⅰ Ex-KSF36600*-U 600*136*85 6.4-20~+55 37 T6 IP66 Ⅰ Ex-KSF48600*-U 600*136*85 6.4-20~+55 48 T6 IP66 Ⅰ Ex-KSF361200*-U 900*136*85 8.7-20~+55 37 T6 IP66 Ⅰ Ex-KSF481200*-U 900*136*85 8.7-20~+55 39 T6 IP66 Ⅰ Ex-KSF561200*-U 900*136*85 8.7-20~+55 42 T6 IP66 Ⅰ Ex-KSF721200*-U 900*136*85 8.7-20~+55 46 T6 IP66 Ⅰ 15

INSTAATION METHOD Candela Distribution 105 105 90 90 75 75 60 60 400 45 600 45 30 15 0 15 30 cdklm C0 - C180 C90 - C270 Installation method 292 Φ40~Φ60 550 500 850 500 180 T 30 625 575 925 575 620 570 920 570 T(Max) 40 5 T(Min) 146 104 128 257 625 575 925 575 Pipe clamp Wall mount Stanchion mount Clamp mount 550 500 850 500 550 500 850 500 Ceiling Mount 16 Pendant Mount

ACCESSORIES Size 600 Unit: mm 900 Unit: mm 136 136 85 85 18W 36W 48W 36W 48W 56W 72W Optional parts NO. Installation accessories Material Weight (Unit: kg) QTY Remarks 1 Bracket Q235 0.8 2 2 oop Q235 1.2 2 3 Pipe Clamp Q235 1.8 2 4 Stanchion bracket Q235 2.6 2 5 Clamp mount Q235 3.0 2 Accessories Bracket oop Pipe Clamp Stanchion bracket Clamp mount Optional Parts 7

SERVICE Caution 1.To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes. 2.To avoid electric shock: Be certain electrical power is OFF before and during installation and maintenance. uminaire must be supplied by a wiring system with an equipment grounding conductor. 3.To avoid burning hands: Make sure lens and housing are cool when performing maintenance. 4.To avoid explosion: 1)Make sure the supply voltage is the same as the luminaire voltage. 2)Do not install where the marked operating temperatures exceed the ignition temperature of the hazardous atmosphere. 3)Do not operate in ambient temperatures above those indicated on the luminaire nameplate. 4)All gasket seals must be clean. 5)Before opening, electrical power to the luminaire must be turned off. Keep tightly closed when in operation. Package Check 1. Check the carton and all the components according to the packing list. 2.Make sure the product is in good conditions. Transportation Please keep this product from heavy mechanical shock, exposure to strong sunshine, throwing, rolling and stress during transport Storage Kept in dry,clean and well-ventilated,non-corrosive medium warehouse,the ambient temperature should be -40 to 55. After-sales service Installation and maintenance must be according to the instruction. If customer can not deal with it by themselves,please contact with sales department. Contact HYGROW SDN BHD -------------------------------------------------------------------------------- Address: No.18, Jalan KP13, Kajang Prima, 43000 Kajang, Selangor. Malaysia. Tel: +603 8739 4663 Fax: +603 8739 4662 E-mail: info@hygrow.com.my Website: www.hygrow.com.my 8