MODEL 6200 ANALOGUE ADDRESSABLE OPTICAL BEAM SMOKE DETECTOR

Similar documents
Motorised Infrared Optical Beam Smoke Detector. User Guide

Reflective Optical Beam Smoke Detector User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Line Smoke Detector LRMX

Installation and Operation Manual

Beam Detectors. The 6500 Series

FIRERAY 5000 range USER GUIDE

Laser Distance Sensor Type M Analog-Output

Table of Contents. 1. Mounting Tips... 2

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Conventional Detectors

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Reflective Beam Smoke Detector

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

FEC400 Series. Installation Manual

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

C-9105R Conventional Reflective Beam Detector Installation and Operation Manual. (Issue 2.01, February 2006)

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

LASER ASPIRATED SMOKE DETECTOR

DI601AM Outdoor PIR/AM Detector Installation Sheet

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

English. Series. Installation and Use Manual

Control Panel User Guide

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Consultant Specification AGILE Wireless Fire Detection System

Installation, Operating and Maintenance Manual

D-Tect 2 GJD300 Quad PIR Movement Detector

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

LASER ASPIRATED SMOKE DETECTOR

mod. ERHSO712 mod. ERRHSO712 ENGLISH CONTROLLER mod. CSRLS MAINTENANCE ADDITIONAL CONTROLS

PHOTO-ELECTRIC BEAM DETECTOR MODEL SPB-ET INSTALLATION PROCEDURE

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Analogue Detectors. Series 200 plus

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. (Issue 2.03 February 2006)

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Model 5610 Infra-red Transit Heat Sensor

INSTALLATION AND MAINTENANCE INSTRUCTIONS TC866E Series LASER ASPIRATED SMOKE DETECTOR

Open-area Smoke Imaging Detector. Engineering Specification

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

LS800S Intruder Alarm System. Engineering Manual

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. The Intelligent Solution CONTENTS

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

Public Safety DAS Annunciator Panel

PHOTOELECTRIC REFLECTIVE BEAM DETECTOR MODEL SRA-ET. Mounting Guidelines

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Analog Room Pressure Monitor RPC Series

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

DUAL OPTIC. Installation manual

Direct Dim Microwave Presence/Absence Detector

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

D2E Duct Smoke Detector

Active Infrared Multi Beam Sensors. R Series

Intelligent addressable fire alarm control panel

FR-A180 FR-A360. Occupancy detector. Use

DYGIZONE GJD910 Lighting Controller & Enunciator

Open-area Smoke Imaging Detection (OSID)

FL2011EI-HS FL2012EI-HS FL2022EI-HS

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

RS Pro Infrared Temperature Sensor

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Software Version 2.01 LEVEL MONITOR MODEL 220

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Installation and user manual for the BiWire / Conventional Repeater Panel

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Fire detection and alarm

FEC403EN Installation Manual

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Snifter ATEX22 VERSION. User Manual. Distributor

New Silent Alert Fire Safe System

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

FDL241-9 Linear smoke detector Mounting Commissioning

End To End Optical Beam Smoke Detector. Additional Information

IR FLAME DETECTOR RIV-601/F

Beacon 800 Gas Monitor Operator s Manual

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

The supplier and installer of the system should be approved by the local civil defence authority.

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Transcription:

MODEL 600 OPTICAL BEAM SMOKE DETECTOR ADDRESS CODING SW0 ON 4 8 4 8 UNITS TENS DIGIT REQUIRED Switch 8 Switch 4 Switch Switch 0 off off off off off off off on off off on off 3 off off on on 4 off on off off 5 off on off on 6 off on on off 7 off on on on 8 on off off off 9 on off off on TABLE - SETTING THE DEVICE ADDRESS ON A 600 Switch setting Chosen sensitivity Relative sensitivity SW5 SW4 SW3 SW SW level Most sensitive = off off off off on maximum off off off on off.3 off off on off off medium.6 off on off off off.0 on off off off off minimum.5 any other Default (minimum).5 TABLE - SENSITIVITY ADJUSTMENT CAUTION Fire detection system components must be installed in accordance with the manufacturers stated operating parameters and with applicable recognised international and national standards or local codes of practice. Design, installation, commissioning and maintenance should be undertaken by competent organisations. Service should be undertaken on a regular basis in line with accepted codes of practice. Detection may not be effective if local conditions change or if equipment is not properly maintained. System sensor warrants this product to be free of manufacturing defects or component failure for three years from original supply but accepts no responsibility for claims of consequential loss as a result of such failures or defects. Defective product will be repaired or replaced when returned via the original distributor. MODEL 600 ANALOGUE ADDRESSABLE OPTICAL BEAM SMOKE DETECTOR Pittway Tecnologica SpA, Via Caboto 9/3, 3447 Trieste, Italy D00-70-00 8 I56-669-00EN

ELECTRICAL SPECIFICATIONS REFERENCES AND DESIGNATIONS Reference Description 600 Analogue Addressable Intelligent linear beam detector 600R Conventional linear beam detector with dry relay contact REFL0 Short to medium range reflector REFL30 Medium range reflector REFL50 Medium to long range reflector 600-BR Remote unit for 600 (refer to Accessory Data sheet) 600-OBK Orientation bracket kit (refer to Accessory Data sheet) 600-C Heating pad kit (refer to Accessory Data sheet) REFL0-C REFL0 Heating pad kit (refer to Accessory Data sheet) REFL30-C REFL30 Heating pad kit (refer to Accessory Data sheet) REFL50-C REFL50 Heating pad kit (refer to Accessory Data sheet) 600 FILTER Filter for alarm test GENERAL The 600 is a reflector-type Linear Optical Beam smoke detector designed to operate as a component of an intelligent analogue addressable fire detection system, powered directly from the loop itself. The detector operates primarily on the principle of light obscuration, i.e. the alarm is triggered as a result of the change in the optical transmission of a beam of light beyond a set threshold. The beam is designed to comply with the requirements of the draft European standard pren54- (998 edition) and is third party tested and approved to that standard. The detector comprises two parts:. A unit containing all the electronics associated with the detector: Light Beam Emitter, Receiver, Signal Processing, and System Communication.. A high-efficiency reflector, which returns the light beam emitted. INSTALLATION RECOMMENDATIONS Installation should be undertaken in accordance with recognised international standards or required codes of practice. See the System Sensor Guide for Proper Use of Projected Beam Smoke Detectors, reference I56-506, for installation guidelines. The following recommendations should also be taken into account: Height of premises (H) Distance of beam to ceiling (D) Area of effective detection (width from beam centre).5 m H 5 m 0.3 D 0.5 m 5 m 5 m H m 0.5 D m 7 m Note : We recommend that simulated fire tests should be conducted to ensure that an adequate speed of response is achieved with the detector spacingutilised on each specific installation. When designing the location and layout of the detectors, the following factors must be taken into account:. No obstruction should obscure the beam. The beam is narrow, but can move across the reflector. Make sure a cone of view is clear for the beam from the 600, the base of which is at Clear cone of view least equal to the overall dimension of the reflector.. Do not place the beam in a location where it may be interrupted by site activity (conveyor belts, fork lift trucks etc.), which can cause unwanted alarms and fault conditions. 3. Ensure the led indicators are clearly visible, unless a remote indicator or repeater unit has been provided. 4. Ensure freedom of access to the detector for installation and maintenance operations. 5. Do not expose the detector or its reflector to radiated light from other beams, or other intense sources of light. 6. It is critical that the transmitter/receiver part of the detector be installed on a rigid support, to prevent unwanted alarms and faults being triggered by structural movement of the building. The size of the reflector must be chosen in relation to the possible movement of the 600 (see the curves on page 7 of this document). The reflector is not subject to the same restrictions. 7. Centre the red spot (visible when unit is switched to installation mode) emitted by the beam onto the reflector in order to provide for maximum tolerance to any structural movement of the building. 8. Install the 600 onto an even vertical surface, which avoids any possible twisting of the termination box. Uneven mounting surfaces can create problems. If necessary, use an intermediate plate, or the optional mounting bracket (600-OBK). 9. Use round headed screws (not countersunk), ø3.5 mm, to mount the termination box. The 600 is light, so avoid excessive screw tightening which might stress the plastic termination box. PARAMETERS 600 Power supply Via intelligent loop (5 to 8 Vdc) Power consumption in standby 3. ma at 0V Power consumption in alarm mode ma at 0V Power consumption in fault mode ma at 0V Power consumption in contamination mode ma at 0V Power consumption in installation mode < 40 ma at 0V Note: Set only one unit per loop to this mode simultaneously MECHANICAL SPECIFICATIONS PARAMETERS 600 REFLEX 0 REFLEX 30 REFLEX 50 Weight kg 0.5 kg kg 3.5 kg Overall dimensions (mm) 95(h) x 55(l) x50(w) 05(h) x 05(l) x 30(w) 305(h) x 305(l) x 30(w) 548(h) x 508(l) x 0(w) Protection number IP4 - - - Material ABS Aluminium Aluminium Aluminium Colour Grey, eggshell finish Grey Grey Grey Mounting Screws at housing fixing Screw fixing lugs Screw fixing lugs Screw fixing lugs points indicated Cable termination Via 5 knock-outs with appropriate cable glands - - - CLIMATIC SPECIFICATIONS PARAMETERS 600 Temperature Operating -0 to +55 C Storage -0 to +70 C Admissible relative humidity Operating Storage OPTICAL SPECIFICATIONS < 95% non-condensing < 95% non-condensing PARAMETERS 600 REFLEX 0 (*) REFLEX 30 REFLEX 50 Range 0 to 00 m 0 to 30 m 30 to 50 m 30 to 00 m Wavelength 670 nm (red) - - - Horizontal/Vertical adjustment ± 0 by screws none None none Allowable movement during normal operation Acceptable angle (±, in degrees) 0.60 0.50 0.40 0.30 0.0 0.0 Refer to table below (*) ± 5 ± 5 ± 5 Acce ptable mov e me nt of the transmitte r/re ce iv e r in re lation to the range and size of reflector used REFLEX 0 REFLEX 60 REFLEX 30 0.00 0 m 0 m 30 m 40 m 50 m 60 m 70 m 80 m 90 m 00 m Range (in m etres) (*) The admissible movement of the beam depends on the range and the surface area of the reflectors. Pittway Tecnologica SpA, Via Caboto 9/3, 3447 Trieste, Italy D00-70-00 7 I56-669-00EN

4 FUNCTIONAL TESTS To test the fault condition Completely obstruct the beam between the transmitter and reflector with a non-reflective material, such as a sheet of cardboard, for example. After approximately 0 seconds:. The yellow fault LED should light. A fault condition should be signalled to the control panel Clear the obstruction from the beam path. After a few seconds:. The yellow fault LED should go out. The device returns to standby on the indicator panel To test the alarm condition Obstruct the beam at or close to the transmitter/receiver unit, using the appropriate ALARM end of the filter supplied (600 FILTER). Insert the filter into the path of the beam at an oblique angle (not perpendicular to the beam path) otherwise it may act as a reflector instead of an obscuration filter. After approximately 0 seconds:. The red alarm led should light. An alarm condition should be signalled to the control panel Remove the filter from the beam path, then reset at the control panel. After a few seconds:. The red alarm LED should go out. The device returns to standby on the indicator panel 30s Obstruct the beam again, this time using the end of the filter marked NO ALARM, checking that the beam and panel do not signal an alarm. OPERATION Standby condition BEAM TEST FILTER This is the normal status for the detector. No LED indicators should be lit. Alarm condition The red alarm LED (under the 600) is lit continuously. The alarm LED will remain lit until the unit is reset under command from the control panel. On the control panel, the relevant visual and audible indicators will operate (see the instructions for the control panel):. Acknowledge the alarm signal. Follow the fire instructions 3. When the cause of the alarm has been investigated and resolved, reset the control panel, which resets the detector (and switches off the red LED). Fault condition The cause of a fault may be due to:. Obstruction / mis-alignment of the beam: In this case, the yellow fault LED is turned on steady. To return to standby status remove the obstruction or re-align to ensure the path of the beam remains clear to the reflector.. Incorrect start-up or detector failure: This fault occurs immediately after exiting the installation mode. The yellow fault LED illuminates continuously. The installation procedure should be repeated and all parameters checked for this fault to be cancelled. 3. Excessive contamination of the optical parts: The yellow fault led flashes. The 600 is capable of compensating the signal for contamination up to a preset limit. Carefully wipe the beam window and the reflector surface clean with a damp cloth then revert to installation mode to check signal strength and beam alignment. The detector should then return to standby. On the control and indicating panel, the relevant visual and audible warnings are triggered.. Acknowledge the warning signals. Go to the zone related to the fault condition and identify the possible cause 3. Inform service personnel, and follow the agreed safety procedures for the installation. REFLEX 0: L = 80 REFLEX 30: L = 8 REFLEX 0 and 30 REFLEX 50 Fastening lugs for 5 mm Ø screws (not included in supply) (Rear view) N.B.: Provision is made to connect several reflectors together if required 53 0 INSTALLATION MOUNTING LIMITS Internal adjustment of the optical assembly within the 600 housing allows the beam to be installed on flat surfaces, inclined up to 0 from the required beam path. Similarly the reflector can accommodate an offset of up to 5 from the beam path. If the angle is greater than those indicated, use the 600-OBK orientation bracket kit for improved alignment. ALIGNMENT RECOMMENDATIONS < 5 The model 600 offers significant set-up advantages by providing easy alignment when using the installation mode, which generates a visible < 0 targeting spot of light. However when setting up at distances greater than 50 meters:. Try to choose the time of installation when the (natural) lighting in the premises is reduced to emphasise spot intensity. Use structural elements (ceilings, girders, partitions etc.) to identify the trajectory of the beam. If necessary, use a largedimension back-up reflector surface to aid the alignment with the final installed reflector. EXAMPLE Flat surface to track spot (upright) 450 Note: The spot has to be centred diagonally on the reflector Final alignment STEP : Finalise setup of the beam using the adjustment screws to centre the red spot on the reflector and optimise signal strength. Sight by eye at the same height as the beam. Pittway Tecnologica SpA, Via Caboto 9/3, 3447 Trieste, Italy D00-70-00 6 3 I56-669-00EN

INSTALLATION It is recommended to use the following steps for set-up: A. Disassemble the beam as shown B. Mount securely to a fixed vertical surface C. Connect field wiring and assemble optical module D. Set the switch configuration as required E. Connect system loop wiring to panel and apply power F. Engineers switch - set to installation position G. Align beam and centre on reflector H. Assemble housing cover I. Engineers switch - set to operating position J. Close the bottom access door WARNING Alarm conditions may be generated during the set-up phase thus the control panel should be switched to engineering mode with outputs isolated until beam detector commissioning has been completed. A. DISASSEMBLE MAJOR COMPONENTS Remove housing cover by releasing captive screws (shown X), then carefully separate optical assembly from rear termination box after releasing captive screws (shown Y) and disconnecting plugs from sockets marked J, J and B on the termination PCB. B. FIX TO VERTICAL SURFACE Maintain minimum clearance distances around beam as indicated in diagram above. Ensure termination back box is fixed securely to a rigid vertical surface directly opposite to the mounted reflector. Do not distort the box moulding by over-tightening fixing screws. (Note: an adjustable mounting bracket is available if required as a special order accessory). C. CONNECT FIELD WIRING AND REFIT OPTICAL MODULE Terminate cables through knock-outs provided in bottom plate (use glands provided or compatible alternatives) Connect to terminals in accordance with details shown. 4 Screws for wall fixing ø5mm required (not included with product) Termination Box J sensitivity configuration to receiver PCB address configuration to laser diode J 34 5 6 7 8 SW0 - B + S.MAX 3 4 5 ON TENS UNITS STANDARD S.MIN SW5 Screen 6 Terminal block 5 for remote 4 box option 3 TERMINATION PCB SW ON J Set configuration ON if remote indicator box is connected, otherwise leave set to OFF Loop connection terminal block BR NC IND - IND + B4 SCR B OUT - OUT + IN - IN + To INDICATOR PCB Intelligent loop connections All dimensions in mm. Note: Z = Screwdriver clearance area (depends on length of screwdriver) Remote Indicator connection Remove protective film before operation Housing Cover D. SWITCH CONFIGURATION Standard (sensitivity) settings recommended Level or, the fastest detection, and the most sensitive, for areas subject to rapid air movement Level 4 or 5, the least sensitive, and the slowest response, for areas with higher contamination (e.g. dust, condensation), or long beam lengths (<70m) Do not select several switches at once otherwise minimum sensitivity is adopted by default; refer to TABLE Set the unit address The address is set in the range 0-99 according to the coding scheme indicated in TABLE and inside the 600 housing cover. E. CONNECT TO PANEL AND APPLY POWER Y X Beam Alignment adjustment screws Optical Module INST OP INDICATOR PCB X Y Alarm and Fault LEDs (underneath) To Socket B Engineer s switch To connector J B J To connector J F. ENGINEERS SWITCH To optimise beam alignment, set switch SW on the Indicator PCB at the bottom of the 600 to the INSTALLATION position. This provides rapid pulsing of laser beam, making visible adjustment easy, in conjunction with the signal LEDs, which indicate the following: SIGNAL HIGH LED ON: The signal is saturated; the reflector must be too close for the sensitivity setting (fit cover onto beam as it adds a little attenuation or use lower sensitivity setting) SIGNAL LOW LED ON: The signal received is too weak, the reflector is too far away or too small, or alignment is not correctly adjusted (ensure separation <00m and align) NO SIGNAL LED ON: No signal detected, the beam is not correctly aligned with the reflector (check alignment). When the beam is aligned correctly only the green SIGNAL OK led should be on. G. BEAM ALIGNMENT AND CENTERING ONTO REFLECTOR Accurate adjustment of the beam may be made in both the vertical and horizontal planes by use of the two adjustment screws indicated (use hex Allen key/wrench no.8). Ensure the focus of the beam is central on the reflector. Line - Line + B4 B 6 5 4 3 NC IND - IND + OUT - OUT + IN - IN + 600 to 600-BR connection B B NOTE : Continuity is only ensured whilst the Detector is powered 600 NC IND - IND + OUT - OUT + IN - IN + 6 5 4 3 Line - Line + 600-BR SW ON BR 600 SW position to ON H. COVER INSTALLATION Replace the housing cover, attaching it using the relevant captive screw marked X. I. ENGINEERS SWITCH - NORMAL OPERATION Only return the Indicator PCB switch SW to the operating position when the cover is correctly refitted. The green led should light up for a few seconds (do not disturb the beam during this time). All indicators should be off in the normal monitoring state. J. CLOSE THE BOTTOM ACCESS DOOR Close the lower Indicator PCB door and fix using the captive screw marked X. B NC IND - IND + OUT - OUT + IN - IN + Remote LED - + Pittway Tecnologica SpA, Via Caboto 9/3, 3447 Trieste, Italy D00-70-00 4 5 I56-669-00EN

600BR Installation and Operating Instructions GENERAL DESCRIPTION 600BR is a Remote Annunciator and Control unit for the 600 range of reflector type linear optical beam smoke detectors permitting easier operation and maintenance of the detector. It is particularly recommended for use in installations where access to the detector is restricted, or if the detector is out of sight. The 600BR offers the following features: LED Indication of a Fire Alarm. LED Indication of Faults. Test points permit monitoring of dirt build up or condensation on the optical parts within the detector hence enabling easy scheduling of maintenance. Alarm Test (key on Test Alarm position). Detector Disabled (key on Disable ). Detector Reset (key from Disable to Normal ) Dry contacts (normally closed or normally open) that indicate the Detector is disabled. WARNING One 600BR should be fitted for each detector to be monitored. The 600BR must not be connected to more than one detector. WALL MOUNTING x 3 mm screws (not included) Installation height:,3 to,5 m The 600BR uses similar mountings to standard electrical back boxes, giving flexibility in mounting the Remote Annunciator and Control unit and allowing the unit to be mounted unobtrusively. Easy access to the 600BR enables all personnel to ascertain the status of the Detector enabling appropriate action to be taken. WIRING CONNECTIONS DETECTOR CONNECTION: B DRY CONTACTS CONNECTOR: B PIN Function 0 V (line -) Fire Alarm lamp control 3 Fault/Dirty lamp control 4 Test point 5 Alarm test 6 Detector disabling 7 Screen PIN Label Function NO Normally open contact C Common 3 NC Normally closed contact Page of Pittway Technologica SpA, Via Caboto 9/3, 3447, Trieste, Italy D00-73-00 I56-734-00

600BR Installation and Operating Instructions KEY SWITCH The key switch has three positions that permit testing or disablement of the Alarm during routine maintenance: NORMAL OPERATION. Normal position of the key switch, allowing normal fire detection system operation ALARM TEST. Tests the operation of the detector s optical parts and electronics. The test simulates fire conditions and gives reasonable assurance that the Beam Detector is operating correctly. DETECTOR DISABLED. Disables the detector if the beam is going to be obstructed. Whilst the detector is disabled, a fault signal is sent to the panel. The yellow LEDs on both the detector and the remote box will be continuously lit whilst the detector is disabled. Briefly turning the key to this position will also reset the 600R following an alarm or alarm test. Note: The Control Panel resets Alarms on the 600 The Key can only be removed in the "Normal Operation" position. Note: All 600BR keys are the same OPERATION STANDBY CONDITION No LED s lit and the key is on Normal Operation YELLOW LED ILLUMINATED If the key is set to Normal operation : then the Detector is in fault status. The yellow LED is turned on continuously when an obstruction to the detector beam or detector failure occurs. FLASHING YELLOW LED Indicates excessive contamination of detector optical parts. If the key is set to Disable then the Detector is disabled. Once the fault is cleared, the yellow LED will automatically turn off. RED LED ILLUMINATED If the key is in the Normal Operation Position, the detector is in alarm. If the key in the Alarm test position, the detector is in alarm test. Following an alarm, or an alarm test, it is necessary to reset the detector either from the control panel ( 600 ) or by briefly switching from the Normal to the Disable position ( 600R ). Note: The Control Panel controls the illumination of the RED LED ( 600 ) SPECIFICATIONS MECANICAL SPECIFICATIONS PARAMETERS Weight Overall dimensions Protection index Colour Mounting Roof fixing Cable termination ENVIRONMENTAL SPECIFICATIONS PARAMETERS Temperature Operating Storage Admissible relative humidity Operating Storage 00 g 08(H)x08(L)x57(W) mm IP55-5 Cool grey RAL7035, blue, yellow x Ø3mm Screws Clips knock-outs - 0 to + 55 C + 0 to + 50 C < 95 % without condensation < 85 % without condensation ELECTRICAL SPECIFICATIONS Power for the 600BR is derived from the detector; maximum cable length 00 m. Note: The use of a 600BR does not increase the power consumption of the detector. TEST POINTS Two 4mm diameter test connectors provide a DC voltage relating to the light power received by the photodiode. These test points must only be used for the connection of a suitable meter capable of reading up to VDC. (Red positive, Black negative) DETECTOR STATUS Detector status is reported by LEDs: A red LED indicates Alarm: In alarm, this LED will be illuminated until the detector is reset. A yellow led indicates a fault: In fault this is continuously lit when an obstruction to the detector beam occurs, and flashes to indicate a dirty Optical Chamber DRY CONTACTS OUPUTS Normally open and normally closed contacts are used to signal alarm disabled. Page of Pittway Technologica SpA, Via Caboto 9/3, 3447, Trieste, Italy D00-73-00 I56-734-00

INSTALLATION MANUAL FOR HEATING ELEMENTS 600-C, REFL-C AND REFL50-C 600-C Heater Kit Mounted on 600 Emitter Receiver Mounting: Power Supply: Wiring: Size: Adhesive: The 600-C Heating Kit should be mounted on the interior of the cover as shown, without obscuring the window. 4VAC or 4VDC +/- 4VDC, 70mA Two V elements wired in series Each element 50mm x 5mm 3M966 REFL-C Heater Kit Mounted on REFL0 or REFL30 Reflectors Mounting: Power Supply: Wiring: Size: Adhesive: The REFL-C Heating Kit should be mounted on the rear of the reflector, in the centre of the area as shown 4VAC or 4VDC +/- 4VDC, 700mA Two V elements wired in series Each element 50mm x 00mm 3M966 REFL50-C Heater Kit Mounted on REFL50 Reflector Mounting: A pair of heating elements should be mounted in the centre of each quarter of the reflector. Power Supply 4VAC or 4VDC +/- 4VDC,.8A Wiring: Size: Adhesive: Eight V elements wired as pairs in series, then in parallel. Each Element 50mm x 00mm 3M966 INSTALLATION Clean the surface on the detector or reflector where the heating elements are to be positioned (see diagrams above). Remove the protective sheet on the self adhesive pads 3 Position the heating elements and press them firmly into place over the whole of the heater surface to ensure good thermal contact is made. 4 Connect the two elements in series to a suitable 4VAC or 4VDC power supply. Do not mix different heating elements series together. Power supply current rating must be a minimum of (70 x n + 700 x m) ma where n is the number of detector heating kits and m the number of reflector kits. RECOMMENDATIONS Do not bend, cut or scratch the heating elements If a heating element has been incorrectly positioned, it is possible to carefully un-stick and reposition it. However this operation may reduce the effectiveness of the adhesive pad, therefore it is advised to add a thin layer of silicon adhesive. 3. Do not connect two different sized heating elements in series. D00-7-00 System Sensor I56-733-00

600-OBKORIENTATIONKIT INSTALLATIONINSTRUCTIONS BEAM DETECTORMOUNTING ONTO 600-OBKORIENTATIONKIT PivotBracket Seebelowfor mountingdetails. OrientationKitBack Plate Mountingontopivotbracket 4xM4x0panheadscrews Detectorbasemountingonto orientationkitback plate 3xM4x0Panheadscrews 3xM4Nuts 3xM4Washers PIVOTBRACKET WALLMOUNTING REFL-0 REFLECTORMOUNTING ONTO 600-OBKORIENTATIONKIT 3xØ6mmholes 30mmThreaded spacer 70mm REFL-0Reflectormountedto pivotbracket: 3xM4x0Panheadscrews xm4nut xm4x30mmthreadedspacer M4Lockwasher PittwayTecnologicaSpA,ViaCaboto9/3, 3447Trieste,ITALY D00-74-00 Lockwasher fitted betweenpivot bracket andreflector SystemSensor 00 I56-748-000