R B10 Series : SMB CARLOCK

Similar documents
Weight / 003 -Z M5 (SUCOFEED ¼ HF) bulk 10 pcs g / 5.25 oz.

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

TECHNICAL DESCRIPTION

RF one-step BNC/TNC connectors for coaxial cable termination

NELSON HEAT TRACING SYSTEMS

Tools & Test Equipment

Jan05 Rev A EC

JUL 18 Rev A1

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Designer & Application Notes. Securtiy Termination. belfuse.com/cinch

Operating instructions ERGOCRIMP die set with positioner Locking TAB REC. 3.3

Platen Heater Pad Replacement

Two Circuit Heavy Duty Burner Connector

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

Dimension drawing. Main feature. Dimension (H x W x D) Cooling capacity *Note. Standalone temperature control. Rated voltage.

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

HMN-D2 Insert Series

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Installation Procedure for D-200 series Shielded Cable Splice Kits with MiniSeal Crimp Primary Splices

HEX200PB Heat Exchanger Instruction Manual

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

USB 3.0 Plug & Receptacle

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description


HOOD TYPE DISHWASHER WD-6. Spare parts manual

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

HEX050QA Heat Exchanger Instruction Manual

Part Lists & Exploded Views

569, 570, 571, 572 Series

Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler. Product Features. Product Description

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

JUL 17 Rev C

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Introducing Hermaphroditic Blade and Receptacle Connector

Apr06 Rev A

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Jun08 Rev C

TECHNICAL DESCRIPTION

Life insurance for your electronics

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

SM CONNECTOR. 1Certified LR R Specifications. Standards. 2.5mm pitch/disconnectable Crimp style wire-to-wire connectors

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

Tools for other contacts Tools for FOC contacts Crimping machine TK-M Crimping machine TC-C

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

M7100 Pressure Transducer

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

569, 570, 571, 572 Series

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

PRE-INSULATED CRIMPING TOOLS. YYT-1 - Ratchet crimping tool for pre-insulated terminals

Z-PACK TinMan 85 ohm Connector Overview

Cooktops - Integrated Modules

AlarmLine Addressable Linear Heat Detector

Hose. Propane Hose. 1 X-treme Low Temp Bobtail Hose. Large Transfer Hose. Construction Tube: Cover: Reinforcement: Temp. Range:

QUADRAX D-SUB CONNECTORS

Mar11 Rev C

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Jun08 Rev A

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

CC150 General Production Hose Crimper

TECHNICAL INSTRUCTIONS

568X, 587X, 588X Series

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Hydraulic Crimping Heads and

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

Helically wound resistance wire coil made

Service Parts Manual Integrated (700-(

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Crimping tools for D-Sub contacts Crimping tools for other contacts Crimping machine TC-C

Tools. Contents Tools for contacts Han D Tools for contacts Han E Tools for contacts Han C

TEMPORARY SPECIFICATION FOR REFERENCE

Reliable connections are your main concern Our stars provide crimping that lasts Let s connect. Connection technology and electrical installation

CR A-F-A-E-HQQE 3x400/ HZ

Power Eagle 1016/1020. Self Contained Carpet Extractor. Operator and Parts Manual

Hydraulic Crimping Head, PN

Heavy Head Hand Crimping Tools (HHHT) [ ]

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Product Alert September 20, 2012

Sprinkler Identification Numbers

PRM-100 INSTALLATION MANUAL OUTDOOR PARAPET ROOF MOUNT WITH ELL CONDUIT BOX MANUAL NUMBER

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

CR20-07 A-F-A-E-HQQE 3x400/ HZ

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

Transcription:

.. pn ao TECHNICAL DATA SHEET 1 / 5 All dimensions are in mm. COMPONENTS MATERIALS PLATINGS (µm) BODY CENTER CONTACT OUTER CONTACT INSULATOR GASKET OTHERS PARTS BRONZE - PTFE NICKEL 2 - - UL CLASSIFICATION COLOR HOUSING PA6.6 GF15 (POLYAMIDE) UL 94 V-2 CREAM WHITE RAL 9001

TECHNICAL DATA SHEET 2 / 5 PACKAGING Standard Unit Other 200 W option Contact us ELECTRICAL CHARACTERISTICS Impedance 50 Ω Frequency 0-4 GHz VSWR 1.20* + 0.000 x F(GHz) Maxi Insertion loss 0.05 F(GHz) db Maxi RF leakage - 45 - F(GHz)) db Maxi Voltage rating 335 Veff Maxi Dielectric withstanding voltage 1000 Veff mini Insulation resistance 1000 MΩ mini CABLE ASSEMBLY Stripping a b c d e Cable mm 2.4 5.5 9.4 0 7.00 RG174 mm 2.4 5.5 9.4 0 7.00 RG58 Assembly instruction : For RG174 cable : see page 3 & 4 For RG58 cable : see page 5 Recommended cable(s) RG 58 RG 174 RG 316 Characteristics indicated on this data sheet are those that can be achieved with the highest performance cable. Intrinsic limitations of the cable may diminish the performance of the assembly Cable retention MECHANICAL CHARACTERISTICS Center contact retention Axial force Mating end Axial force Opposite end Torque Recommended torque Mating Panel nut Clamp nut A/F clamp nut Mating life Weight 10 N mini 10 N mini mini 0.000 mm 100 Cycles mini 7.50 g ENVIRONMENTAL *** Depends on the cable used Operating temperature -40/+110 C *** Hermetic seal NA Atm.cm3/s Panel leakage NA SPECIFICATION SAE/USCAR-17 & Rev.1 USCAR-18 (October 2002) SAE/USCAR-2 Rev.3 (February 2001) SAE/USCAR-18 Rev.2 (January 2003) - pull off RG58 110 N mini RG174 JUDD CABLE 110 N mini RG316 110 N mini RG174 65** N mini TOOLING Référence Désignation Hexagone RG174 (2.6/50S) CABLE R282.293.000 CRIMPING TOOL R282.235.915 CRIMPING TOOL Square 0.72 R282.235.916 RIGHT CRIMPING Hex 3.25 TOOL R282.235.917 LEFT CRIMPING Hex 3.25 TOOL OR R282.281.000 CRIMPING TOOL 2x4pts 3pos R282.967.034 POSITIONER RG 58 (5/50S) CABLE R282.293.000 CRIMPING TOOL R282.235.910 CRIMPING DIES Square 1.1 R282.235.011 CRIMPING DIES Hex 5.41 OR R282.281.000 CRIMPING TOOL 2x4pts 7pos R282.967.034 POSITIONER OTHERS CHARACTERISTICS * VSWR : 1.20 maxi at 4 GHZ ** According to the cable used, for more details, please contact us.

TECHNICAL DATA SHEET 3 / 5 Recommended mounting procedure for RG174 cable e a 1 Slide the ferrule onto the cable Strip the cable 2 Slide the centre contact on until it bottoms against the cable dielectric Crimp the centre contact with crimping tool R282.293.000 (M22520/5-01) + dies R282.235.915 (square 0.72) or R282.281.000 (3 position) (2x4pts) with positioner R282.967.034. VIEW WITH DIES ONLY Center contact at the bottom After crimping

TECHNICAL DATA SHEET 4 / 5 Recommended mounting procedure for RG174 cable 3 Fan the braid 4 Slide the cable into the body until it bottoms against insulator 5 VIEW WITH DIES ONLY Slide the ferrule over the braid Crimp the ferrule as shown on the picture with crimping tool R282.293.000 (M22520/5-01) + dies R282.235.915 (Double crimping Hex 3.25). Check the position of the center contact between the top of the center contact and the SMB ref. plane : 0.57 ±0.165 Right tool orientation :after crimping the bump must be closer to the cable than to the body

TECHNICAL DATA SHEET 5 / 5 Recommended mounting procedure for RG58 cable COMPONENTS Centre contact STRIPPING DIMENSIONS Ferrule e a Heatshring sleeve (option) Body b c 1 4 Slide the heatshrink sleeve onto the cable (Option). Slide the ferrule onto the cable. Strip the cable. Slide the cable into the body until it bottoms against insulator. 2 5 Slide the centre contact on until it bottoms against the cable dielectric. Crimp the centre contact with crimping tool R282.235.910 (square 1.1) or with crimping tool R282.281.000 (7 position 2x4pts) + positioner R282.967.034. Slide the ferrule over the braid. Crimp the ferrule with crimping tool R282.235.011 (Hex 5.41). After crimping 3 Fan the braid. 6 Check the position of the center contact between the top of the center contact and the SMB ref. plane : 0.57 ±0.165.