PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Similar documents
PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VP 18 BY NILAN. Sanitary hot water production. Heating. Active heat recovery. Comfort heating. Ventilation < 300 m 3 /h.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

VENTILATION = WELL-BEING

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Comfortable indoor climate regardless of the season

Technical specifications

PRODUCT DATA NILAIR BY NILAN. Air distribution. Domestic. Ventilation

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

PRODUCT DATA COMPACT P RANGE BY NILAN. Heating. Sanitary hot water production. Ventilation < 300 m 3 /h. Passive heat recovery.

Installation Instruction

VEX100 series Air handling units with cross-flow heat exchanger

Endura Delta. Demand- and app-controlled ventilation system with heat recovery

Technical Information HXV - HRV Ventilation

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

USER MANUAL CTS700 TOUCH BY NILAN. Compact P / Compact P Polar (English)

Decentralised comfort ventilation unit Zehnder ComfoSpot 50

KOMFORT EC DB Suspended heat recovery air handling units

TSEK VHR EC HEAT RECOVERY UNITS

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Healthy, comfortable and energy-efficient ventilation

CONTENT: VEX308 Decentralised ventilation VEX308

Healthy, comfortable and energy-efficient ventilation

Energy recovery unit. Projection documents

The new Xcell EC High Efficiency Range Fresh air pure and simple

TopMaster Air Handling unit. Technical data

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Energy-efficient heat source provides comfort in large rooms

Heat and energy recovery ventilators

Zehnder ComfoAir 550. Ventilation unit

RoofVent Design Handbook

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

CLIMASTER ZCF AIR HANDLING UNITS

User manual. CTS 602 by Nilan VPL 15 VPL 15 TOP. Version: 9.02, Software-version: 2.21

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

TopVent Design Handbook

Ventilation in balance

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

SOFTWARE MANUAL CTS700 TOUCH BY NILAN. Compact P / Compact P Polar GEO (English)

Technical Information HCV - HCH Demand-controlled home ventilation

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

VERSO Air Handling Units

CI/SfB (57.5) November 2008

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

Operation and maintenance instructions

DEMAND-CONTROLLED HOME VENTILATION

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

VERSO Air Handling Units

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

User manual. User manual. CTS 600 by Nilan. Comfort Comfort Version: 10.00, Software-version: 2.30

Auxiliary Equipment and Accessories

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

VENTILATION WITH HEAT RECOVERY

INSTALLATION INSTRUCTIONS

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Installation instruction

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation

l i nda b we si mpl i f y c onstr u ction Conforms ErP Ecodesign Lot 6 Residential and non-residential air handling units

InspirAIR Home RESIDENTIAL AIR PURIFICATION

User Manual. Vanvex Optima 180 Domestic Hot Water. Version

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

MRXBOXAB-ECO3 MRXBOX-ECO3

Heat recovery unit RDKS

MRXBOXAB-ECO2 MRXBOX-ECO2

CTS 602 by Nilan. Compact P. Compact P Sun. Compact P Cool. Compact P Cool Sun. Version: 5.00, Software-version: 2.11

Sentinel Demand Energy Recovery Ventilation

User's Guide. CTS6000 control panel

Series VENTS VUT R WH ЕС

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Flexit air handling units C2 and UNI 2, 3,4

TURBO HOODS. Product Brochure

Technical Data Ducted Three Phase Split System Air Conditioner

CONTENT: VEX300C Ceiling units VEX320C/330C

Heat recovery unit. Installation Manual

Transcription:

PRODUCT DATA COMFORT 450 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 450 m 3 /h

COMFORT 450 Product description The Comfort 450 is an energy-efficient ventilation unit with heat recovery for homes and smaller commercial buildings with a ventilation requirement of up to 450 m 3 /h. This unit has been thoroughly tested, with improvements being continually made during its manufacture for more than 15 years. These have focused on low energy consumption, easy user operation and maintenance. The Comfort 450 is a compact unit which can be ordered as a left- or right-handed model. The Comfort 450 is factory tested and ready for use. Installation and commissioning must be performed by an authorised electrician. Comfort 450 A A B C D E F G A 48 db 525 m 3 /h ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE ENERGI 2016 1254/2014 2

COMFORT 450 BY NILAN The large door provides easy access for changing filters and cleaning the unit. Counterflow heat exchanger made of polystyrene, which has a higher temperature efficiency than aluminium exchangers. The unit comes with a clear and user-friendly operating panel. The modern CTS 602 control panel runs Modbus communication. Intelligent humidity sensors provide an option for controlling the ventilation as required, based on the average air humidity in the home. A CO 2 sensor can be purchased as an accessory. The powder-coated condensate drain prevents the formation of acid water and allows the condensate to be drained away. The efficient fans are powered by energy-saving EC motors. They provide a constant air volume with a four-step adjustment. Filter monitor with timer G4 filters are supplied as standard, but it is also possible to buy a F pollen filter as an accessory. Prepared for an integrated or external water heating element. The automatic bypass damper makes the outdoor air bypass the heat exchanger when heat recovery is not required, thereby saving energy. Bypass cooling as an option. 3

TECHNICAL DATA Technical specifications Dimensions (W x D x H) 1100 x 650 x 640 mm Supply voltage 230 V (±10 %), 50/60 HZ Weight (1*) 2/51.5 kg Max. input/power 30 W/2.9 A Plate type casing Aluzinc steel plate Tightness class IP31 Heat exchanger type Polystyrene counterflow heat exchanger Standby power 3 W Fan type EC, constant volume Ambient temperature -20/40 C Filter class Standard G4 Heat loss (3*) 0,82 W/m 2 K Duct connections Ø 200 mm Heat loss classification T2 Condensate drain Leakage classification (2*) PVC, Ø 20 1,5 mm A1 *1 33 kg is without side plates and exchanger *2 Testet according to EN13141- *3 Testet according to EN1886 Data ecodesign SEC* average climate -39,8 kwh/(m 2.a) AEC - annual electricity consumption 5,0 kwh/år SEC* cold climate -, kwh/(m 2.a) AHS** average climate 45,2 kwh SEC* warm climate -15,5 kwh/(m 2.a) AHS** cold climate 88,5 kwh SEC-Class A AHS** warm climate 20,4 kwh Type Residential ventilation unit ** Annual heating saved Type of drive Variable speed drive Type of heat recovery system Thermal efficiency of heat recovery Recuperative (counterflow heat exchanger) 86 % Maximum flow rate Electric power input of fan drive, including any motor control equipment, at maximum flow rate Sound power level L WA) Reference flow rate Reference pressure difference SPI 525 m 3 /h (100 Pa) 190 W 48 db(a) 0,102 m 3 /s (36 m 3 /h) 50 Pa Central demand control 0,85 Maximum internal leakage 1,9 % Maximum external leakage 0, % 0,22 W/(m 3 /h) A A B C D E F G Comfort 450 A A yellow light flashes on the user panel when filters need changing. 48 db 525 m 3 /h Visual filter warning To maintain the performance and energy efficiency of the unit it is very important to change filters regularly. Disassembly instructions www. nilan.dk * Specific energy consumption ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE ENERGI 2016 1254/2014 4

COMFORT 450 BY NILAN Dimensional drawing All dimensions are in mm. Left model Ø200 1100 650 3 1 640 2 4 650 Ø200 1100 Ø650 200 1 195 6 3 1 5 453 3 2 4 5 6 650Ø 200 650 Ø200 1 3 640 4 2 640 4 5 195 Right model 453 6 195 3 2 640 640 2 453 1 4 6 195 453 5 1100 6 195 453 5 Connections 1: Fresh air 2: Supply air 3: Extract air 4: Discharge air 5: Condensate drain 6: Electric and water heating : Primary side (heat exchanger) 5

PLANNING DATA Nilan units are tested in accordance with the valid standards of accredited independent test institutes. Capacity p t,ext (Pa) Capacity of standard unit as a function of q v and P t, ext. 350 SFP values according to EN 13141- are for standard units with G4 filters and without heating element. 300 250 200 SFP values comprise the unit s total power comsumption incl. control. 150 100 1000 J/m 3 Max Pa Conversion factor: J/m 3 = W/m 3 /h 3600 50 800 J/m 3 0 250 300 350 400 450 500 550 0 80 90 100 110 120 130 140 150 q v (m 3 /h) q v (l/s) η t (%) Temperature efficiency Temperature efficiency for units with counterflow heat exchanger according to EN308 (dry). 100 98 96 94 92 Temperature efficiency EN308: ɳ t = (t supply air-t fresh air)/(t extract air-t fresh air) 90 88 86 84 82 80 0 50 100 150 200 250 300 350 400 450 q v (m 3 /h) 0 20 40 60 80 100 120 q v (l/s) Sound data Sound data for q V = 300 m 3 /h and P t, ext = 100 Pa according to EN 9614-2 for surfaces and EN 5136 for ducts. Sound output level L WA drops with falling air volume and falling back pressure. Sound output level L pa at a given distance will depend on acoustic conditions in the place of installation. Sound output level (L WA ) Octave band Hz Surface db(a) Supply air db(a) Extract air db(a) 63 29 56 38 125 40 56 40 250 41 5 3 500 46 61 32 1000 40 59 22 2000 29 58 22 4000 1 55 1 8000 14 54 15 Total ±2 db(a) 48 66 44 6

COMFORT 450 BY NILAN Capacity - Heating element (accessory) Electrical heating surface The electrical heating surface is fitted in the air inlet duct at a distance of min. 2 x duct diameter from the system s fresh air inlet connection pipe (normally min 320 mm.) and connected to the CTS 602 control panel and power supply. Electric heating element can be ordered for the Comfort 450, with an output of 3.0 kw (230V). Water heating element for internal fitting The water heating element is designed to be built into the system and must be connected to the primary heating supply and the CTS 602 control. The water heating element includes copper pipes and aluminium fins. Capacities can be seen in the table below. Capacity water heating element Water side Air side Temperature input/output [ C] Flow [m 3 /h] Pressure drop [kpa] Output [kw] Flow [m 3 /h] Temperature before WHE* [ C] Temperature after WHE* [ C] Pressure drop over WHE* [Pa] 0.05 1.6 0.61 100 16 34 2 40/30 0.1 5 1.13 220 16 31.1 3 0.14 8. 1.6 350 16 29.3 5 0.18 13.5 2.03 500 16 2.9 9 0.05 1.3 1.11 100 16 48.6 2 60/40 0.09 3.8 2.05 220 16 43.3 3 0.13 6.9 2.8 350 16 40 5 0.16 10. 3.66 500 16 3.5 9 0.04 0.8 1.28 100 16 53.6 2 0/40 0.0 2.3 2.34 220 16 4.1 3 0.09 4.1 3.24 350 16 43.1 5 0.12 6.3 4.12 500 16 40.1 9 * Water heating element.

AUTOMATION CTS602 Control The Comfort 450 is controlled using its CTS 602 operating panel, featuring a wide range of functions, e.g., menu-controlled operation, weekly programme settings, filter monitor with timer, fan speed adjustment, summer bypass (free cooling), post-heating element control, error messages etc. The CTS 602 comes with factory settings, including a default setting which can be customised to operational requirements to achieve optimum operation and utilisation of the system. The operating panel must be placed in a dry, frost-free location, at least 1.5 m above floor level and at least 0.5 m from any corner. Avoid placing the panel on an external wall or in areas in direct sunlight. Operating instructions for the CTS 602 can be found in a separate user manual supplied with the unit. Functional diagram 1 T8 T3 3 T10 4 T4 T9 T2 T 2 TC 5 6 Connections 1: Fresh air 2: Supply air 3: Extract air 4: Discharge air 5: Condensate drain 6: Electric and water heating Automation T2/T: Supply air sensor T9/TC: Heating element frost protection T3: Extract air sensor T4: Discharge air and defrost sensor T8: Fresh air sensor T10: Room sensor 8

COMFORT 450 BY NILAN Functional overview Standard - Accessories 3 levels The control function is divided into 3 levels: User/Service/Factory with various options at each level Weekly plan User option 1 User option 2 The unit has 3 weekly programmes (with a factory setting of off ) Programme 1: for working families Programme 2: for stay-at-home families Programme 3: for businesses There is also an option for you to set your own weekly programme. This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor. With an Expansion PCB mounted, allows you to make additional connections, e.g. User option 2 overrides User option 1 (e.g. connecting an EM box) Up to 500 W direct Output relai Switching the central heating system on/off Alarms Alarm log featuring the last 16 alarms. Datalog Possible to log data. Kapacity 46.000 logs Adjustable between 1 and 120 minutes If OFF, only events and alarms are logged Filter monitor Filter monitor with timer (factory setting of 90 days). Adjustable to 30/90/180/360 days. Bypass Bypassing the outdoor air reduces heat recovery when heat recovery are not needed. Air quality Allows you to choose whether to switch humidity sensors and/or CO 2 sensors on and off. /- Humidity control Allows you to set a higher or lower ventilation step in the case of high/low air humidity. CO 2 control Allows you to set a higher or lower ventilation step in the case of a high CO 2 level. - - Summer/Winter operation Possible to set operation for summer and vinter Winter low Allows you to select a low ventilation step in the case of low outside temperatures Defrost function Temperature-based automatic function for defrosting the heat exchanger. Frostprotection Temperature control Room low Air volume In case of failing heating system, the unit is turned off to avoid further cooling with a risk of the water heating coil frost bursting. Allows you to select the temperature sensor which will control the unit. T15 ROOM (panel sensor) T10 EXT (fitted in a representative extraction valve) T3 EXHAUST (extract air) Stops the unit at a low room temperature. Hereby is cooling of the home avoided in case of a failing central heating system. Standard set to OFF. Can be set from 1 to 20 degrees and is controlled by: T15 ROOM (panel sensor) T10 EXT (fitted in a representative extraction valve) T3 EXHAUST (extract air) Allows you to set four ventilation steps stepless. Supply air and extract air are set individually. Step 1 < 25% - Step 2 < 45% - Step 3 < 0% - Step 4 < 100% External firealarm Possible to connect the unit to external firealarm. Joint alarm Outlet for joint alarm Constant pressure control Allows control from both the extract air and supply air side. - Cooling Intake air control External heating element External electric heating element Via bypass (can only cool with outdoor temperature) and cool recovery (can only cool with indoor temperature). This allows you to choose whether to run the system at a higher or the highest ventilation step during cooling. The weekly programme has an option for setting cooling at night. Allows you to set the regulator to control the intake air temperature/supply air (only available if the control unit has been configured for a supply-heating element). Temperature sensor T is an supply air sensor Integrated frost protection for external water heating element Motorised valve and circulation pump control unit Temperature sensor T is an supply air sensor Overheating protection Delayed start-up There is a possibility for a delayed start-up by the fans, when a closing damper is installed. Reset Allows you to restore the factory settings. Manual test Allows you to test the unit s functions manually. Language Option for setting the relevant language (Danish/Finnish/Norwegian/Swedish/German/English/ French). - - 9

COMMUNICATION External communication The CTS 602 control unit communicates by default with Modbus RTU RS485 communication. A CTS system using this form of communication can easily be connected to the unit. Nilan units have an open Modbus communication, i.e. not only can the unit be monitored, but its operation can also be set in the same way as it can via the operating panel. CTS / Computer Konverter Modbus The protocol is set up by default for a Modbus RTU 30 address, but can be set to a value between 1 and 24. A Modbus converter allows you to connect one or more units to a computer to monitor and control the unit. OPERATION Intelligent humidity control Nilan s humidity control automatically adapts to the needs of the family or the building. The intelligent CTS 602 control unit does not need to have a set level input for air humidity (RH) to control the air exchange. By using the integrated humidity sensor, the control unit calculates the average level itself for the last 24 hours. The average level provides a basis for deciding whether to change the air exchange if the air humidity fluctuates. This ensures that the unit always runs at its most efficient, based on the actual air humidity level and not on a theoretical one. Immediately change in % of RH 11 10 9 8 6 5 4 3 2 1 Reduced ventilation Forced ventilation Normal ventilation This helps save energy because it automatically adapts to the requirements in the home. Whether a large family or a single person is living in the building has a considerable influence on how much humidity is produced. The unit also adjusts automatically to summer and winter level. 10 20 30 40 50 60 0 80 90 100 Average RH (the last 24 hours) If the air humidity changes by more than 5-10% in relation to the average level, the unit responds with a higher rate of air exchange accordingly. At an air humidity below 30% is reduced ventilation stp activated (adjustable between 15 and 45%) 10

OPERATION COMFORT 450 BY NILAN Frost protection All ventilation units with a counterflow heat exchanger will ice up if the outdoor temperature is below freezing for a prolonged period. ɳt[%] The extracted air condenses when it is cooled down during heat recovery. The high temperature efficiency will slowly turn the condensate to ice, which will block up the counterflow heat exchanger unless action is taken to remedy this. Consideration must be given to whether the unit s operation can be protected during a lengthy period of frost or whether it is acceptable to decrease its operation. Temperature efficiency With pre-heater Defrost function t Außen > -3 C t Außen < -3 C In homes which are occupied at night, it would be advisable to protect the unit against frost when the outdoor temperature is coldest by using a pre-heating element. On the other hand, if the ventilation is for an office, it may be acceptable to decrease the operating level at night. Operation Ice building Defrost Ice building Defrost The energy used for the preheating is not wasted, as it ensures a constant high temperature efficiency Frost protection Normal operation No Outdoor temperature < -3 C After 30 min. Yes Pre-heater installed Yes No Normal operation secured until outdoor temp. < -12 C Defrost function starts when: Outdoor temp < 1 C (T8) Discharge air < 3 C in 5 min. When outdoor temp. < -12 C reduced air volume 1. Bypass damper opens 2. The intake motor switches off 3. Warm extracted air will flow through the heat exchanger 4. The ice is melting The example below shows the energy used to frost protect versus defrosting. Air volume 126 m 3 /h 216 m 3 /h Frost protection when outside temperature is -2 C -2 C Hours during the year 66 66 Energy used to frost protection via pre-heating 10 kwh/a 183 kwh/a Loss of energy when icing 105 kwh/a 180 kwh/a Loss of energy when deicing 200 kwh/a 343 kwh/a Energy savings by using frost protection 198 kwh/a 340 kwh/a Defrosting stops when: Discharge air > C (T4) Average calculation by Danish dry weather data. 11

ACCESSORIES CO 2 -sensor With a CO 2 -sensor installed, the ventilation speed can be pre-programmed with CTS602 to run at a higher ventilation steps when CO 2 reaches high level in the extract air. CO 2 -level is programmable. Water heating element incl. regulation The supply temperature can always be raised to the required level using a water heating element. The water heating element is designed to be built into the unit and must be connected to the primary heating supply. Supplied with two-way adjustment valve, temperature sensor and frost thermostat. Electrical heating surface incl. regulation When you fit an electrical heating surface, you can raise the fresh air temperature to the desired level at any time. The electrical heating surface is supplied ready to fit into the fresh air duct and, for easy fitting, the device is pre-fitted with all the required sensors. Electrical pre-heating element (Frost protection) An electrical pre-heating element heats up the outdoor air before it enters the unit. This avoids having to defrost the unit, resulting in a loss of power. There are temperature sensors supplied to be fitted in the ducts. EM-box An EM-box allows heat recovery from the air from the range hood and thereby helps to heat the supply air. The EM-box is equipped with a special filter which efficiently cleans the range hood air of fat particles and thereby protects the system. Expansion PCB The expansion PCB provides additional functions for the CTS 602 control unit, e.g., controlling the EM box (see list of functions on page ). Pollen filter F A pollen filter in class F can be fitted in the unit. The pollen filter is fitted with the G4 plate filter. Installation kit The installation kit comprises of four vibration absorbers and a water trap for the condensation outlet. The water trap can be ordered separately. Heating cable To protect the condensation outlet against frost, a 3 metre-long self-regulating heating cable can be ordered. 12

DELIVERY AND HANDLING COMFORT 450 BY NILAN Transport and storage Comfort 450 comes in factory packaging that protects it during transport and storage. Comfort 450 must be stored in a dry place in its original packaging until installation. The packaging should only be removed immediately prior to installation. Installation conditions During installation, future service and maintenance should be taken into account. We recommend a minimum gap in front of and behind the unit of 60 cm. The unit must be installed level for the sake of the condensate drain. The condensate drain requires clearance of min. 12,5 cm under the drain nozzle. Min. 60 cm Min. 12,5 cm Installation of electric heating element Electric heating elements (accessories) are fitted in the duct. The fitter should ensure that there is a safe distance of at least 15 cm between the electric heating element and any inflammable material. The heating element must be insulated using fire-resistant insulation material. The electric heating element must be connected by an authorised electrician. Min. 15 cm Electric pre-heating element with temperature sensor Electric heating element Min. 40 cm Min. 40 cm 13

NILAIR NilAIR is installed together with a ventilation unit,which in simple terms consists of distribution boxes from which tubes are led out to air extraction and air supply boxes in the individual rooms. NilAIR can be installed in ceilings, walls or floors. The lightweight tubes can be used for even the most complicated tube alignments, where e.g. traditional spiral ducts cannot be used. Advantages Enabling the impossible Flexible and space-saving solution Rapid and simple installation with a click system Dimensionally stable and corrosion-resistant quality material Simple regulation of the air supply volume Low weight Airtight Easy to clean Easy to handle and transport Prevents sound travelling from room to room Traditional air distribution systems take up a lot of space and often make special building structures impossible. NilAIR virtually eliminates this problem, due to the tubes size and flexibility. NilAIR is already installed in thousands of European homes and since its introduction more than ten years ago its use has steadily increased, due to the rapid and easy installation without any special tools being required. Installation examples 14

NILAIR PRINCIPLE NILAIR BY NILAN Air extraction (mounted in wall or ceiling) Kitchen Ventilation unit Utility room Bathroom Bathroom Distribution manifold extract air (mounted in floor or ceiling) Soundflex Distribution manifold supply air (mounted in floor or ceiling) Living room Room Room Family room Bedroom Air supply (mounted in floor, wall or ceiling) 15

INFORMATION FROM A TO Z Nilan develops and manufactures premium-quality, energy-saving ventilation and heat pump solutions that provide a healthy indoor climate and low-level energy consumption with the greatest consideration for the environment. In order to facilitate each step in the construction process from choosing the solution through to planning, installation and maintenance we have created a series of information material which is available for download at www.nilan.dk. Brochure General information about the solution and its benefits. Product data Technical information to ensure correct choice of solution. WWW.NILAN.DK Nilan A/S Nilanvej 2 822 Hedensted DEnmark Tel. 45 6 5 25 00 Fax 45 6 5 25 25 nilan@nilan.dk www.nilan.dk Installation instructions Detailed guide for installation and initial adjustment of the solution. User manual Detailed guide for regulation of the solution to ensure optimum day-to-day operation. Visit us at www.nilan.dk to find out more about our company and solutions, download further information and find your nearest dealer. 6 650 453 453 Drawings Tender documents and 3D drawings are available to download for planning purposes. 2 1 4 5 640 640 Ver. 3.00-2015.12 Nilan A/S assumes no responsibility for any errors or omissions in the printed information material or for loss or damage that may follow from the use of such published materials - whether such loss of damage is caused by errors or inexpediencies in the material or otherwise. Nilan A/S reserves the right without prior notice to change products and information material. All trademarks are the property of Nilan A/S. All rights reserved.