Operating Instructions

Similar documents
Operating Instructions

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

Certification Supplement Manual

INSTRUCTION & SERVICE MANUAL

Certification Supplement Manual

INSTRUCTION MANUAL (ATEX / IECEx)

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

standards: standards:

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Flameproof Manual Call Points

Earth-Rite II PLUS Static Earthing System

IECEx Certificate of Conformity

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

Certificate of Compliance

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Manual Power relay SR853

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Inductive slot sensor

4) Intrinsic Safety Certification

Gas cylinder scale Model GCS-1

Manual for QX0201 Push Button

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Certificate of Compliance

OPTIWAVE X500 Supplementary Instructions

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Snifter ATEX22 VERSION. User Manual. Distributor

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

DTS Light fittings for explosive atmospheres

IECEx Certificate of Conformity

Certification Supplement Manual

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

INSTRUCTION MANUAL (ATEX / IECEx)

Important Safety Instructions. Important Safety Instructions

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

High bay LED lighting fixture

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

ATM Lighting sp. z o.o

AZN ATEX INSTALLATION AND MAINTENANCE

INSTRUCTION MANUAL (ATEX / IECEx)

Explosion-proof Immersion Heater Type D-8660

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Flameproof Manual Call Points Series MCP

official distributor of Newson Gale Ltd.

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

Centurion Guided Radar HAWK CGR SERIES

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Annubar Flowmeter Series

Explosion Proof Combination Signal db (A) / 5 Joule

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

14300 MAINS SEPARATOR ALARM MANUAL

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

SOLUZIONI PER ATMOSFERA ESPLOSIVA

IECEx Certificate of Conformity

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Dräger Polytron 5720 IR Toxic Gas Detection

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Rosemount 3490 Series

Performance Data. curus Component Recognized; File No. E IP 20

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5100 EC Detection of toxic gases and vapors

VERSAFLOW VORTEX Supplementary instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

XLFE-4/1. Borosilicate glass globe

Technical Data. Dimensions

Guide for hazardous areas

INSTRUCTION MANUAL (ATEX / IECEx)

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Operating Instructions

Hazardous Area Portable Fan Heater The Bulldog

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Transcription:

Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect installation, operation or maintenance Operating Instructions Languages English

Safety Instruction: The installation, operation and maintenance must be carried out by an electrician suit ably trained in hazardous areas with knowledge of increased safety explosion protection IEC 60079-07 The technical data indicated on the LED fixtures are to be observed. Changes of the design and modifications to the LED fixture are not permitted Repairs must only be carried out by a qualified electrician with hazardous area knowledge Observe the national safety rules and regulations during installation. NO user serviceable Parts inside. NO field replaceable parts. DO NOT open when energized or when an Explosive atmosphere may be present Potential electrostatic charging hazard REFER TO INSTRUCTIONS WARNING: Cable entry may reach 93 C Clean only with damp cloth Technical Data Category of Application: Ex II 3GD Ex na nc IIC T4 Gc Ex tc IIIC T130 C Dc IP66 Operating Temp: T4 = -40 C to +65 C IECEx: IECEx SIR 14.0042X ATEX: Sira 14ATEX4097X Input Voltage: Input Power: Housing Material: Finish: Lens: Weight: Without J/BOX Single with J/BOX 100-277 VAC 50/60Hz 21W (HZB0, HZB1, HZJB0, HZJB1) 38W (HZB2, HZB3, HZJB2, HZJB3) 47W (HZB4, HZB5, HZJB4, HZJB5) 57W (HZB8, HZB9, HZJB8, HZJB9) 68W (HZBE, HZBF, HZJBE, HZJBF) Powder Coated Aluminum Epoxy Powder Coat Gray RAL 7040 Glass 7.44kg 7.67kg Dimensions: See figure 1 Conformity with Standards This equipment conforms to the standards specified in the Declaration of Conformity. It has been designed, manufactured and tested in accordance with BS EN 9001. ATEX Directive 2014/34/EU Equipment and protective systems intended for use in potentially explosive atmospheres. EMC Directive 2014/30/EU for electromagnetic compatibility. Equipment Application This lighting equipment is intended for use in a potentially explosive atmosphere in Zones 2 and 22 to the requirements of ATEX Directive 2014/34/EU. Installation Ensure that the mains voltage supply is disconnected before connecting the luminaire. Install the equipment in accordance with the manufacturer s instructions as well as any other applicable electric codes. Always transport and store the equipment in its original packaging and keep in a dry location. When unpacking check for any cracks or damage in the housing, glass, and glass frame. If in doubt, do not install. Electrical Connection: COLOURED CABLE NUMBERED CABLE LIVE BROWN 1 NEUTRAL BLUE 2 GROUND GRN/YEL 3 Mounting Luminaire Secure the luminaire using the four fixing locations on the stirrup bracket using fixing bolts not supplied. *When installing on or over an existing junction box, a cable gland must be used when routing cable through centre wiring hole on stirrup bracket. Conditions for use Improper installation and operation of this luminaire may invalidate the warranty. For maximum long term reliability and light output, the luminaire must be installed in free air. Installation (Junction Box Versions) Ensure that the mains voltage supply is disconnected before connecting the luminaire. Install the equipment in accordance with the manufacturer s instructions as well as any other applicable electric codes. Pay attention when re-fitting the lid to the enclosure; make sure the seals are clean and undamaged. Do not allow any cables to become trapped between the lid and the enclosure and tighten all four screws evenly to 1.7Nm. Cable Entries When assembling the cable entries for the mains connection, always observe the manufacturer s specifications for the glands used. Unused cable entries must be closed and sealed by a suitably certified Ex e/ex tb blanking element which includes a sealing o-ring. The cable entries should be securely tightened to ensure that the minimum protection rating is achieved. The cable entry device should be a suitably certified Ex e/ex tb cable gland which includes a sealing o-ring to maintain the protection level of the fixture. Cable glands and blanking elements must be fitted with a locknut in order to maintain certification. Threaded entries are intended for guidance only. Electrical Connection The terminal block is suitable for multi-stranded and single core cables up to a maximum of 4mm 2, strip length 10mm. Single Fixture Electrical Connections: Push down at the cross point on the terminal block, insert correct wire lead and release, ensuring the wire lead has been securely retained. The cable used must be suitable for the site application and/or the site requirements. Loop Thru Electrical Connections: Connect incoming cable then connect the outgoing cable to the associated adjoining connection to pass to the next luminaire. ONLY SINGLE CABLES TO BE USED ON EACH CONNECTION. Taking into Operation Prior to operating, check the luminaire for its correct installation in compliance with these operating instructions and other applicable regulations. Do not over tighten as the protection rating may be compromised. The glands must be suitable for use within an operating temperature range of -40 C to +90 C. The gland is required for increased safety protection, the entry thread shall be suitable sealed (in accordance with IEC 60079-14) to maintain the ingress protection rating of the fixture. Electrical Connection When connecting the conductors extra care should be taken in order to maintain the hazardous protection. The insulation of the conductors shall reach up to the terminal block. The conductor itself shall not be damaged. The connectible minimum and maximum conductor cross sections shall be observed (see electrical connection data). Remove any foreign bodies from the fixture Taking into operation Prior to operating, check the luminaire for its correct installation in compliance with these operating instructions and other applicable regulations. Attention: Only fully certified equipment may be put into operation. Improper installation and operation of this luminaire may invalidate the warranty.

Maintenance Disconnect the power supply to the luminaire before maintenance or repair. Wait at least 10 minutes before opening the lid of the luminaire after de-energizing. This LED Luminaire should require a minimum amount of maintenance. If any unforeseen repairs are required then always observe explosion protection regulations and requirements. Inspection Within the scope of maintenance or inspection routine the following should be included. Protective hoses covering the connection cables, Cable entries must be free of corrosion. Perform visual mechanical and electrical inspections on a regular basis. We recommend routine checks to be made on a yearly basis. Frequency of use and environment should determine this. It is recommended to follow an Electrical Preventive maintenance Program as described in NFPA 70B: Recommended Practice for Electrical Equipment. Chemical Compatibility Guide The chemical compatibility data referenced in this manual was supplied by the raw material manufacturers and is intended as a general guide. The data represents the basic material properties and does not necessarily represent the performance of the final product due to manufacturing process and design variations for each final product. Chemical compatibility is highly dependent on concentration, temperature, humidity, and other environmental conditions and therefore the customer assumes responsibility for evaluation of gaseous or direct contact chemical compatibility at their site prior to product installation. For general guidelines describing chemical compatibility, visit us at: www.dialight.com/pubs/mdtfchemrflx001.pdf Inspect cooling fins on the luminaire to ensure that they are free of any obstructions or contamination (i.e. excessive dust build up). Clean with non abrasive cloth if needed Repairs / Overhaul / Modification The relevant national regulations which apply to the maintenance / servicing of electrical apparatus in explosive atmospheres shall be observed. Should the Luminaire enclosure be damaged, only a replacement will be permitted. In case of doubt, the equipment should be returned to Dialight Corporation for inspection/repair. Modifications to the device or changes of its design are not permitted. The equipment must be operated according to the intended purpose in a perfect and undamaged condition. Disposal Recycling When the apparatus is disposed of, the respective national regulations on waste disposal should be observed.