Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

Similar documents
ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EN54 INFORMATION UNPACKING...

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EMC COMPATIBILITY UNPACKING...

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

EXTINGUISHING AGENT RELEASE MODULE

Document No Issue 4 product manual

5000 INSTALLATION GUIDE

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

ZXSe Range Data Sheet

Product Data Sheet. Remote Terminals. Features:

Document No Issue 4 user manual

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

Intelligent Security & Fire Ltd

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Installation, Operating and Maintenance Manual

Touch 10. The operation and functions described in this manual are available from Software Version onwards.

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Intelligent Security & Fire Ltd

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Excel-EN Conventional Fire Control Panel

The EN54 Part 2 & 4 Fire System

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

Carbon Monoxide Transmitter

user manual Document No , Revision 03 November 2015

OPERATION / INSTALLATION

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

FEC403EN Installation Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

1X-F Series Installation Manual

FMR Installation Instructions. Addressable Fire System Controller

OPERATION AND INSTALLATION MANUAL

VSN PLUS VSN 4 PLUS ; VSN 8 PLUS ; VSN 12 PLUS

KM300 Carbon Monoxide Detection System Installation Manual

General Routing Interface

Application, Installation, Operation & Maintenance Manual

EN54 & ISO Zone Conventional Fire Control Panel

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

ID50/60. installation, commissioning & configuration manual

USER MANUAL FOR OPERATING SYSTEM

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

Installation and user manual for the BiWire / Conventional Repeater Panel

The EN54 Part 2, 4 and 13 Fire System

Control Panel Engineering and Commissioning Instructions

EN54 & ISO Zone Conventional Fire Control Panel

FEC400 Series. Installation Manual

Fire Alarm Panels. Product Manual.

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

5000 Series Rack Panels

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

Vocia VACIE. Reference Guide

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

VACIE REFERENCE GUIDE REVISION 1.2.6

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

KFP-AF Series Fire Alarm Control Panel Installation Manual

Operation and Maintenance Manual

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

ORION Mini-Rep INSTALLATION MANUAL

U ser's Guide PC6010

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

ID50series. intelligent fire alarm panels

System 800 Addressable Fire Detection & Alarm System

Networked Access Control Panel. Installation Guide

Door Release Power Supply

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

The supplier and installer of the system should be approved by the local civil defence authority.

ID2000. intelligent fire alarm panel

Analog Room Pressure Monitor RPC Series

Ax60+ Multi-Gas, Quick Connect Option

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Ax60 Carbon Dioxide Detector

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

10yr O2NE & Safe-Ox. User Manual

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

The EN54 Part 2 and 4 Fire System

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Fire control panels FC360

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Conventional Fire Alarm System 2014 V1.2

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

Transcription:

ZXr-A ZXr-P Document No. 996-144 Issue 02 operation & installation manual

MORLEY-IAS ZXr-A / ZXr-P Repeaters Table of Contents 1 INTRODUCTION... 3 1.1 NOTICE... 3 1.2 WARNINGS AND CAUTIONS... 3 1.3 NATIONAL APPROVALS... 3 2 DESCRIPTION... 4 3 INSTALLATION... 4 3.1 MOUNTING THE REPEATER TO THE WALL... 5 3.1.1 Using the Bezel Kit... 5 3.1.2 Direct Mounting... 6 3.2 FITTING THE LABEL INSERTS... 6 3.3 INSTALLATION WIRING... 7 3.3.1 DC Power... 7 3.3.2 RS485 Communications... 8 3.4 ADDRESS SETTING... 9 3.5 COMMISSIONING... 10 3.6 PRELIMINARY CHECKS... 10 3.7 POWERING THE REPEATER... 10 3.8 CONTRAST ADJUSTMENT... 10 4 OPERATION AND CONTROLS... 11 4.1 LIQUID CRYSTAL DISPLAY... 11 4.2 LED INDICATORS... 11 4.3 CONTROL PUSHBUTTONS AND KEY SWITCH... 12 4.3.1 Test Key (ZXr-A Only)... 12 4.4 BUZZER... 13 4.5 SPECIAL LCD MESSAGES... 13 5 SPECIFICATIONS... 14 Table of Figures FIGURE 1 - BACK BOX FIXING AND APERTURE DIMENSIONS... 5 FIGURE 2 - EARTH CONNECTIONS... 5 FIGURE 3 - REPEATER ENCLOSURE FIXING DIMENSIONS... 6 FIGURE 4 LABEL INSERT LOCATIONS... 6 FIGURE 5 EXTERNAL WIRING TERMINATION POINTS... 7 FIGURE 6 SAFETY EARTH TERMINATION POINT... 7 FIGURE 7 RS485 RE-LEGEND LABEL POSITION... 8 FIGURE 8 TYPICAL RS485 PERIPHERAL LINK ARRANGEMENT... 8 FIGURE 9 TERMINATION JUMPER POSITIONS... 8 FIGURE 10 CONTRAST ADJUST BUTTON... 10 Table of Tables TABLE 1 - ADDRESS SWITCH SETTINGS... 9 TABLE 2 - LED FUNCTIONS... 11 TABLE 3 CONTROL KEY FUNCTIONS... 12 TABLE 4 - ZXR-A / ZXR-P REPEATERS SPECIFICATIONS... 14 Page 2 of 16 Document No. 996-144, Revision: 02, Operation & Installation Manual

ZXr-A / ZXr-P Repeaters MORLEY-IAS 1 Introduction 1.1 Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be correct. However, the manufacturer assumes no responsibility for inaccuracies and reserves the right to modify and revise this document without notice. These instructions cover the operation and installation of the ZXr-A / ZXr-P Repeaters. Refer to the Fire Alarm Control Panel (FACP) Manuals for instructions on powering up, operating and programming the system. ZXr-A / ZXr-P Repeaters can be used on systems installed with ZXr4B / ZXr5B repeaters and there are no known compatibility issues. 1.2 Warnings and Cautions These instructions contain procedures to follow in order to avoid injury and damage to equipment. It is assumed that the user of this manual has been suitably trained and is familiar with the relevant regulations. All equipment is to be operated in accordance with the appropriate standards applicable This panel is CE Marked to show that it conforms to the requirements of the following European Community Directives: Electromagnetic Compatibility Directive 89/336/EEC (and the amending directive 92/23/EEC) Low Voltage Directive 73/23/EEC EN54! The ZXr-A / ZXr-P Repeaters have been designed to comply with the requirements of EN54-2:1997, when used as a secondary display. EN54! EN54-2 12.5 Integrity of The ZXr-A / ZXr-P Repeaters are connected to the FACP via the transmission paths: Peripheral Loop 2-wire RS485 communications circuit. The peripheral link Refer to the FACP installation manual for further information and does not provide for recommended cables. the required transmission path integrity. 1.3 National Approvals This equipment must be installed and operated in accordance with these instructions and the appropriate national, regional and local regulations specific to the country and location of the installation. Consult with the appropriate Authority Having Jurisdiction (AHJ) for confirmation of the requirements. Operation & Installation Manual Document No. 996-144, Revision: 02, Page 3 of 16

MORLEY-IAS 2 Description The Remote Repeater provides an extension to the operation of the Fire Alarm Control Panel (FACP). Both types of Repeater show (repeat) the operational state of the FACP using the 2x40 LCD and the LED indicators. The ZXr-P Passive Repeater will only show (repeat) the operational state of the FACP. The ZXr-A Active Repeater will show (repeat) the operational state of the FACP and can control the FACP using the SOUND ALARMS, SILENCE / RESOUND, MUTE BUZZER, ACCEPT and SYSTEM RESET functions. The Repeaters are connected to the FACP via the Peripheral Bus RS485 data link. The FACP supervises the ZXr-A Active Repeater. A Fault will be indicated, at the FACP, if communications is lost with the Repeater. The ZXr-A / ZXr-P Repeaters are compatible with the ZX1e, ZX2e, ZX5e and older ZX Range of Fire Alarm Control Panels 1. An optional Bezel Kit, containing back box and bezel, is available for pre-installation (P/N 002-600-002). The ZXr-A has in-built self-test functions that can be invoked using the buttons. The LCD contrast can be adjusted on both repeaters. ZXr-A / ZXr-P Repeaters ZXr-A (Active Repeater) ZXr-P (Passive Repeater) 3 Installation Ensure that the operating ambient temperature is in the recommended range +5 C to +35 C and that the relative humidity is between 5% and 95%. DO NOT locate the repeater where it may be exposed to high levels of moisture, vibration or shock. This equipment contains transient protection devices. Although no system is completely immune to lightning transients and interference, for these devices to function correctly, and to reduce susceptibility, this equipment MUST be earthed correctly. As with all solidstate devices, this system may operate erratically or can be damaged if subjected to lightning induced transients. The use of overhead or outside aerial wiring is not recommended due to the increased susceptibility of nearby lightning strikes. The installation process consists of 4 steps, as follows: 1. Mount the Bezel Kit (if required) OR fix the enclosure to the wall (if Bezel Kit is not required) 2. Fit the label inserts 3. Install and connect the wiring and set the repeater s address 4. Perform the commissioning checks Before attempting to install the ZXr repeater, remove it from the packaging and inspect for any damage that may have occurred during transit. In the unlikely event that damage has occurred, DO NOT install the repeater but return it to the supplier using the original packaging. 1 ZX Series comprises ZX1e, ZX2e, ZX5e, ZX1, ZXa, ZXe and ZXMi-EN. Does not include ZX50. Page 4 of 16 Document No. 996-144, Revision: 02, Operation & Installation Manual

ZXr-A / ZXr-P Repeaters MORLEY-IAS 3.1 Mounting the Repeater to the Wall The ZXr repeater should be wall mounted in a position that allows clear visibility of displays and easy access to operating controls. The height above floor level should be chosen such that the LCD is just above normal eye level (approximately 1.5 metres). DO NOT site the ZXr repeater where there would be restricted access to the internal equipment and cabling / wiring connections. 3.1.1 Using the Bezel Kit The Bezel Kit is supplied with a dedicated back box that has three fixing holes on the rear wall and two fixing holes on each side. This procedure covers the use of the rear fixing holes but can be applied to the side fixings. Make a recess in the wall large enough for the back box to be inserted easily and without unnecessary force. Allow for space required for cable entry into the back box. With the bezel still attached to the back box, offer the assembly to the recess to check for correct depth and clearance. Repeat this process until the correct depth and clearance have been achieved. Support the bezel / back box assembly in the desired position in the recess and mark the three screw fixing positions (X) as shown opposite. Remove the assembly from the recess. Using an appropriate sized drill bit, drill and plug the three holes to take up to No. 8 (4mm) wood screws. Alternatively, use the side fixing holes (Y). Prepare all required knockouts and fit cable glands as required (Refer to Wiring Installation Section). 175 130 22 88 58 Y Y Side View 22 92 X 307 263 Bottom View 219 110 X Rear View 90 267 Depth 179 Height & Width Recommended Aperture Dimensions Figure 1 - Back Box Fixing and Aperture Dimensions To avoid distortion of the back box when preparing knockouts, place the appropriate back box face on a supporting surface (e.g. work bench). X 218 Orientate the bezel / back box assembly correctly, off it to the recess, then feed the cables through the glands and take up any excess slack. Secure the assembly in position using appropriate sized screws do not use countersunk-headed screws. To avoid distorting the back box, do not over tighten. Prepare the repeater for fitting by removing the appropriate knockouts as required. Insert one of the supplied cable grommets into the upper knockout on the rear wall of the repeater (this knockout is required / used for an earth connection). Correctly orientate the repeater, hold the door open and off the repeater to the installed bezel / back box assembly. Feed all cables through the prepared knockouts and full insert the repeater into the bezel / back box aperture. Use the four M4 SEM screws supplied in the kit to secure the repeater to the assembly (for location of the repeater mounting holes, refer to the Direct Mounting instructions below). Connect the free end of the back box earth lead to the earth connector provided on the inside of the repeater enclosure (top left corner). Use a suitably sized cross-headed screwdriver to tighten at the earth point. Ensure good connection is made. Top Left of Enclosure Figure 2 - Earth Connections Operation & Installation Manual Document No. 996-144, Revision: 02, Page 5 of 16

MORLEY-IAS 3.1.2 Direct Mounting To ensure that the repeater electronics remain clean and undamaged, it is recommended that the front door of the enclosure be covered before the enclosure is fixed to the wall. Keep the cover in place until the repeater is ready for commissioning. To prevent distortion, the repeater enclosure MUST be mounted on a surface that is as flat a possible. If the wall is not flat use appropriate packing pieces to level it up. The drawings opposite show the enclosure fixing dimensions in millimetres. Fixing holes are 5mm in diameter. Mark the position of the fixing holes. Using an appropriate sized drill bit, drill and plug three holes in the mounting surface. Prepare the knockouts required for cable access. Using three 5mm screws (do not use countersunk headed screws), fix the enclosure to the mounting surface. 20 130 ZXr-A / ZXr-P Repeaters 253 126 161.5 51 Template for Mounting Repeater Directly to Wall 165 Use these holes if mounting Directly on Wall Use these holes if mounting in Bezel Kit Back Box Figure 3 - Repeater Enclosure Fixing Dimensions 3.2 Fitting the Label Inserts Disconnect ALL power and open the repeater door. The repeater is supplied with legends in one or more languages. Select the appropriate language set. At position A (see opposite), insert the LED legends label. Fold the perforated line (the fold rests against the side of the door). Ensure correct orientation. At position B, insert the push button legends label. Fold the perforated line (the fold rests against the side of the door). Ensure correct orientation. This label is not used on the ZXr-P. C B A At position C, insert the MORLEY-IAS logo legend label. Ensure correct orientation. Figure 4 Label Insert Locations Page 6 of 16 Document No. 996-144, Revision: 02, Operation & Installation Manual

ZXr-A / ZXr-P Repeaters MORLEY-IAS 3.3 Installation Wiring For further information on recommended cable types, refer to the relevant FACP Installation Manual. 3.3.1 DC Power Only terminate the repeater power cables at the FACP or external source after ALL precommissioning checks have been performed. Only connect power cables when the system power is OFF. The ZXr-A / ZXr-P Repeaters must be supplied with DC Power from an approved and compatible regulated 24-Volt DC Power Supply, suitable for Fire Protection use. If dc power is supplied from the FACP, do not exceed the maximum AUX current rating or the battery standby conditions in quiescent or alarm conditions (refer to FACP specifications). Connect the DC Power to the 28V IN (18-32V dc) and 0V IN terminals, from the previous repeater, peripheral, FACP or external source. If required the DC Power Supply can be daisy chained on to the next unit on the loop. Connect 28V OUT and 0V OUT to next repeater or peripheral. Ensure that the correct size of cable is used to maintain the required DC Supply Voltage at the furthest unit DO NOT connect any wires to the POWER FAIL and 0V terminals. 0V IN 28V IN 0V OUT 28V OUT 0V POWER FAIL RS485 IN RS485 OUT 0V 28V 0V 28V 0V PF Connect Power Cable Earth (Cable Shield) to Safety Earth Point A B A B RIBBON CABLE (INTERNAL) OPTIONAL RIBBON CABLE (INTERNAL RS232 BOARD) Route cables as shown and tie down to enclosure using cable ties to positions provided The terminal designations are clearly marked on the Connection Board. Figure 5 External Wiring Termination Points The enclosure MUST be connected to a safety earth. Connect the safety earth wire to the safety earth point. This is clearly marked on the inside top left of the enclosure rear wall (see diagram opposite). Top Left of Enclosure Figure 6 Safety Earth Termination Point Take care not to inadvertently connect the A & B RS485 terminals to the DC Power Supply. Otherwise, damage may occur to the RS485 input of the Repeater and / or to RS485 Interface Circuit in the FACP or other unit. Operation & Installation Manual Document No. 996-144, Revision: 02, Page 7 of 16

MORLEY-IAS ZXr-A / ZXr-P Repeaters 3.3.2 RS485 Communications Before commencing installation of the RS485 communications wiring, check to which type of panel the repeater is to be connected. 2 If the repeater is to be connected to a ZX Series FACP, peel off and affix the supplied re-legend label over the text on the Termination PCB (see opposite). RS485 IN RS485 OUT 0V 28V 0V 28V 0V PF B A B A For ZX Line, Place supplied label here over existing text. Figure 7 RS485 Re-legend label Position Connect the RS485 serial communications wires from the FACP or previous repeater / peripheral to the RS485 IN (A and B) terminals. Fire Alarm Control Panel Repeater 4-Way Sounder Repeater IN OUT IN OUT IN OUT IN OUT 0V 24V E A B A B A B A B 0V 24V E A B A B 0V 24V E A B A B If required, continue to wire the remainder of the peripheral link by connecting the outgoing cable to the RS485 OUT (A and B) terminals. EOL Figure 8 Typical RS485 Peripheral Link Arrangement EOL The maximum permitted length of the peripheral link is 1.2km (4000 ) for further information, refer to the FACP Installation Manual. If the repeater is at the end of the line, set the Termination Jumpers on the repeater chassis assembly PCB to TERM ON position (JP2/4/6). If the repeater is not at the end of the line, set the Termination Jumpers to TERM OFF position (JP1/3/5). Setting the jumpers to TERM ON effectively places an EOL resistor as shown in Figure 8. DO NOT use the 150ohm EOL resistors supplied with the FACP RS485 card. ADDRESS SWITCHES JP1 JP3 JP4 TERM OFF TERM ON JP2 JP4 JP6 TERMINATION JUMPERS Figure 9 Termination Jumper Positions ALL external wiring must be screened and terminated, using suitable plastic glands, to satisfy local wiring codes. Route the cables alongside the DC Power cables and tie down to the back box using cable ties to the positions provided (refer to figure 5). DO NOT connect the RS485 screen / drain wire to the safety earth point directly. The screen should only be connected to earth at one point connect the other end of the screen to earth via a 2.2uF (non-polarised) capacitor. Refer to the FACP Installation manual for further details. 2 ZX Series comprises ZX1e, ZX2e, ZX5e, ZX1, ZXa, ZXe and ZXMi-EN. Does not include ZX50. Page 8 of 16 Document No. 996-144, Revision: 02, Operation & Installation Manual

ZXr-A / ZXr-P Repeaters MORLEY-IAS 3.4 Address Setting Set the repeater address in binary using the address switch on the repeater chassis assembly PCB. (See Figure 9 above). The address can be set in the range 1 126. It is not necessary to set an address for the ZXr-P (passive) repeater. The address can be set to 0 (all switch positions OFF). In this mode, the passive repeater will listen to the RS485 communications and will update its Liquid Crystal Display and LED with the appropriate information. However, if the repeater becomes disconnected from the RS485 link, the FACP will not report a fault condition. To report a fault condition at the FACP, in the event that a passive repeater becomes disconnected, set the passive repeater to an address in the range 1 126. Refer to Table 1 for address positions. When commissioned, use the panel Auto-Learn function to learn / register the devices installed on the peripheral loop. ADDRESS SWITCH POSITION SW1:1 SW1:2 SW1:3 SW1:4 SW1:5 SW1:6 SW1:7 SW1:8 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF Etc. 126 OFF ON ON ON ON ON ON OFF Table 1 - Address Switch Settings ON 8 7 6 5 4 3 2 1 OFF Operation & Installation Manual Document No. 996-144, Revision: 02, Page 9 of 16

MORLEY-IAS ZXr-A / ZXr-P Repeaters 3.5 Commissioning 3.6 Preliminary Checks Carry out the following preliminary checks for EVERY repeater being commissioned prior to power up the system. 1. Check that all cables brought into the repeater have been terminated correctly. All power and signal cabling and wiring must conform to the appropriate local regulation. 2. Check that the address has been set correctly. 3.7 Powering the Repeater Power up the FACP and power up any Repeater that uses a local independent power supply. Check that the LCD shows the System Normal message. Adjust the contrast (see below) if required. To power down the Repeater, power down the FACP (including battery disconnection) and then power down any repeaters that use a local independent power supply. The repeater can be powered down first, but the FACP will then report a fault condition. 3.8 Contrast Adjustment The LCD contrast can be adjusted electronically to compensate for temperature and height. Open the enclosure door and then press and hold the contrast adjust pushbutton on the chassis assembly PCB (see opposite). Whilst the button is held down, the display will cycle through 11 preset contrast levels, numbered 5 to +5 (see sample LCD display below). Release the contrast adjust button when the desired contrast level is on the display. The repeater saves this setting in non-volatile memory so that it will be remembered even when power is removed. ZXr-P Only: When the button is released, the repeater will automatically enter a 30 second self test to check the LCD and LED Indicators. Contrast Adjust Button CNT Figure 10 Contrast Adjust Button = +1 Page 10 of 16 Document No. 996-144, Revision: 02, Operation & Installation Manual

ZXr-A / ZXr-P Repeaters MORLEY-IAS 4 Operation and Controls The ZXr-A / ZXr-P Repeaters are equipped with a backlit 2x40 Liquid Crystal Display and LED Indicators to show the status of the Fire Alarm Control Panel (FACP) and the installation. In addition, the ZXr-A is equipped with a key operated switch and five CONTROL keys and a TEST key. The operation of the Repeater is as follows: 4.1 Liquid Crystal Display The operation of the liquid crystal display is identical to the display on the FACP. Under normal conditions it will simply show the time and date, together with a message to show that the detectors are working normally. The backlight is normally off. It will turn on for 30 seconds whenever a key is pressed. It will always turn on during a fire alarm condition. If any fault or fire alarm conditions occur, these will be displayed on the display. If several faults or fires have occurred, then these will be scrolled on the display. Refer to the FACP Manuals for information on the messages that are displayed. 4.2 LED Indicators The LED indicators (except DC Power) will be illuminated in response to signals from the FACP. The LED Indicators are a sub-set of the indicators on the FACP. The following table indicates the function of each LED indicator. Refer to the FACP Manuals for further information on the function and operation of each LED indicator and on the operation of the system. FIRE Fault Accepted Disablement Silenced Comms. Fail Power Indicator Colour Function FIRE Red The panel has detected a fire alarm condition, or the Sound Alarms key has been pressed. Fault Yellow The panel has detected a fault. Accepted Yellow A fault or fire alarm has been acknowledged and the internal buzzer silenced. [After pressing the Mute Buzzer or Accept keys at either the FACP or the Repeater]. Disablement Yellow Part of the system, either input or an output, has been disabled. Silenced Yellow The sounder outputs have been silenced. [After pressing the Silence / Resound key at either the FACP or the Repeater]. Comms. Fail Yellow The repeater has lost contact / communications with the FACP and is unable to update its LCD and LED indicators. The control buttons on the ZXr-A will not function during this condition. Power Green ON: Indicates DC Power is present. Table 2 - LED Functions Operation & Installation Manual Document No. 996-144, Revision: 02, Page 11 of 16

MORLEY-IAS 4.3 Control Pushbuttons and Key Switch The ZXr-A Repeater is equipped with five control keys for SOUND ALARMS, SILENCE / RESOUND, MUTE BUZZER, ACCEPT and SYSTEM RESET and a TEST key. To enable the control keys, insert the key and turn the lock (clockwise) to the Enable position (open padlock). The operation of these keys is identical to the control keys on the FACP and is detailed in the following table. System Reset Mute Buzzer Accept ZXr-A / ZXr-P Repeaters Sound Alarms Silence / Resound Self Test Key Legend Symbol Function Sound Alarms Silence / Resound Press to Turn on ALL Sounder Outputs (i.e. evacuate building manually). Press to Turn off all activated sounders. Press again to re-activate the sounders. Mute Buzzer Press to silence the internal buzzer. 3 Accept Press to accept a Stage 1 Investigation Delay Alarm System Reset Press to cancel all alarm conditions and reset the panel. Self Test Press to exercise the in-built test functions. Table 3 Control Key Functions It is recommended that the control key be not left in the active state. Turn the key (anti-clockwise) and remove from the Repeater. 4.3.1 Test Key (ZXr-A Only) On pressing the TEST key, the repeater will perform a self-test exercising the LCD and LED indicators. The test function will remain active for 30 seconds (or 30 seconds after last button press) after which, the repeater indications will return to show the current system condition. The LED Indicators will be illuminated in sequence. The LCD will show a series of vertical stripes at each character position growing in width. If one of the control keys is pressed, the display shows a letter of the alphabet corresponding to the key. Reset = R, Mute Buzzer = M, Accept = A, Sound Alarms = E and Silence / Resound = S. Examples are shown below: 3 The ACCEPT key is not used on ZX1, ZXa, ZXe and ZXMi-EN panels. Use the MUTE BUZZER key instead. Page 12 of 16 Document No. 996-144, Revision: 02, Operation & Installation Manual

ZXr-A / ZXr-P Repeaters MORLEY-IAS Examples of LCD during display test: Example of LCD Test Display when Control Key pressed: MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM 4.4 Buzzer The internal buzzer will sound to indicate alarm or fault conditions as follows: FIRE ALARM The buzzer will sound continuously FAULT The buzzer will sound intermittently, 1 second ON, 1 second OFF In addition, the buzzer will emit a short beep whenever a control key is pressed. During Communications Failure, the buzzer will sound intermittently. 4.5 Special LCD Messages The LCD will show the software part number and version when communications is lost with the FACP and on power up of the repeater. For example: SW993-662 V1.0 The LCD will show the following message if the wrong type of membrane / fascia label is fitted or if no membrane / fascia label is detected on power up. The following message is shown. The buzzer will also sound a fault condition. MEMBRANE ERROR!! Operation & Installation Manual Document No. 996-144, Revision: 02, Page 13 of 16

MORLEY-IAS ZXr-A / ZXr-P Repeaters 5 Specifications Mechanical Construction Dimensions Weight Terminals Criteria Environmental Details Mild steel sheet enclosure with 3 mounting holes, 5 x 20mm knockouts in top and 3 x 20mm knockouts in rear wall. All displays and controls are carried on the enclosure door. 165.0mm (h) x 253.5mm (w) x 50.0mm (d) 1.7kg approx. Climatic Classification 3K5, (IEC 721-2-3) Operating Temperature Humidity Height above sea level Panel Sealing Vibration EMC Safety Electrical Operating Voltage External connections are made using screw terminals capable of accepting cable sizes between 0.5mm 2 to 2.5mm 2 (14-22AWG). -5 C to +45 C (recommended +5 C to +35 C) 5% to 95% R.H. non condensing 2000m IP30 (EN60529) EN60068-2-6, 10-150Hz at 0.981ms (meets the requirements of EN54-2/4) Emissions: EN50081-1. Immunity: EN50130-4 EN60950 18-32V dc Quiescent Current 60mA @ 24V (Backlight off) Alarm Current 90mA @ 24V (Backlight on), 100mA @ 18V Maximum Fault Current Communications Address Range Controls and Indications Display Status Indicators Push Buttons Buzzer Absolute maximum = 600mA. Resetting thermal fuse nominal 250mA. RS485 2-wire serial communications link 0, 1-126 (0 is unmonitored) 2 x 40 character liquid crystal display (LCD) with back light illumination LED Indicators for FIRE, FAULT, DISABLEMENT, ACCEPTED, SILENCED, COMMUNICATIONS FAILURE and POWER. Control keys for RESET, MUTE BUZZER, ACCEPT, TEST, SOUND ALARMS and SILENCE / RESOUND. Table 4 - ZXr-A / ZXr-P Repeaters Specifications -2 Page 14 of 16 Document No. 996-144, Revision: 02, Operation & Installation Manual

ZXr-A / ZXr-P Repeaters MORLEY-IAS NOTES Operation & Installation Manual Document No. 996-144, Revision: 02, Page 15 of 16

MORLEY-IAS ZXr-A / ZXr-P Repeaters MORLEY-IAS. All rights reserved. The MORLEY-IAS Logo is a registered trademark. MORLEY-IAS Fire Systems, Charles Avenue, Burgess Hill. West Sussex. RH15 9UF. England. Page 16 of 16 Document No. 996-144, Revision: 02, Operation & Installation Manual