CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Ls Vegas, NV (702) FAX (702)

Similar documents
CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

1.2 To ensure the safety of all persons working in or occupying a building where a hot work operation is performed.

Hot Work Program & Operational Guidelines. Environmental Health, Safety and Emergency Management (828)

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

HOT WORK SAFETY PROGRAM:

Bloomsburg University of Pennsylvania Hot Work Safety Program Effective Date: July 1, 2015

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

Safe Operating Procedure

Chapter 12 HOT WORK OPERATIONS. Purpose:

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

UC Irvine Environmental Health & Safety TITLE: FIRE WATCH AND OUT OF SERVICE NOTIFICATION

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

POLICY STATEMENT: Policy Number: Section 600 Physical Plant. Date Adopted: May 7, Date(s) Revised: September 4, 2012

HOT WORK OPERATIONS March 23, 2018

Doc #: 2100-AD Revision: - 4M Fire Watch Procedures. Author(s): Tammie Lavoie

HOT WORK PERMIT PROCEDURES

Title: Fire Prevention During Welding, Cutting and Other Hot Work Plan (formerly the Cutting & Welding Policy)

Hot Work Policy and Procedures

Date Issued: December 14, 2017 Revision: 2.1

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

JEFFERSON COUNTY PUBLIC SCHOOLS FIRE WATCH PROGRAM

Chapter 18 Welding Table of Contents

FIRE PREVENTION IN THE USE OF CUTTING OR WELDING PROCESSES

Procedure DESCRIPTION/OVERVIEW

HeatExchangerSpares.com Ltd HRS Heat Exchangers Ltd HRS Hevac Ltd HRS Hevac Engineering Ltd HRS International Ltd HRS Investments Ltd

ADMINISTRATIVE SERVICES MANUAL

Phase 2 Security Response

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

Fire Prevention STANDARD. LME-12: Uen Rev A

Combustibles - Gases, liquids or solid materials that will ignite in the continued presence of an ignition source.

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau. Permit fees shall be assessed in accordance with the Permit Fee Schedule

Office of Risk Management EHS Hot Works Program

Mount Laurel Fire Department, Office of The Fire Marshal FIRE WATCH NOTIFICATION

Demolition Permit Application (Please print and complete ENTIRE form)

OXNARD FIRE DEPARTMENT Fire Watch Guidelines

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Fire Prevention Plan

University of Maryland FIRE EVACUATION PLAN

Safety Policy and Procedure

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.:

Fire Safety Plan Information. For Construction and Demolition Sites

Should you have further questions, please feel free to contact the Fire Prevention Branch.

Fire Prevention Plan

Cedar Hammock Fire Rescue Standard Operational Guidelines FIRE WATCH. General. Requirements for a Fire Watch

Progressive Safety Services LLC 2

Safety & Security Services Services de Sûreté et Sécurité. Hot Work Protocol

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

Builders Risk - Fire Prevention Inspection Checklist

FIRE PROTECTION PROGRAM

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

FIRE PROTECTION & PREVENTION

This policy applies to all Hot Work jobs performed on the Calhoun mill property by AbitibiAbitibiBowater employees.

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

This policy may also be used for routine work orders that are Life Safety in nature and cannot be completed within 45-days.

BURN NOTICE: KEEP THE HEAT AWAY!

FIRE SAFETY AND PREVENTION POLICY

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Impairments to Fire Protection Equipment

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

Winnipeg Fire Department Fire Prevention Branch

(h) Pesticide Application.

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

UNIVERSITY OF TOLEDO

Safety Best Practices Manual

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Temporary LPG Heat for Construction Sites Information Packet

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

DUQUESNE UNIVERSITY. Fire Protection System Impairment Program (Red etag Permit)

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

Fire Prevention Plan for St. Barbara Hall 3904 Winding Way

First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] Submitter Information Verification. Committee Statement 11/18/2016 2:25 PM

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

Risk Management Services

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

SCALES NW EMERGENCY ACTION PLAN

Emergency Action Fire Prevention Plan

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Palm Beach State College Florida s First Public Community College FIRE PREVENTION PLAN

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

2010 FIRE CODE OF NEW YORK STATE

FIRE PREVENTION PLAN EMERGENCY ACTION

Management Practices: Fire Protection Impairments November 2015

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Fire Safety Plan (FSP) Review Checklist 1

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

RE: PERMIT REQUIRED TO WORK ON FIRE ALARM SYSTEMS IN THE RMWB

FIRE SAFETY PLAN ADMINISTERED BY: DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY

FIRE SAFETY PRACTICES AND PROCEDURES

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

Subchapter 7. General Industry Safety Orders Group 27. Fire Protection Article 157. Portable Fire Extinguishers. Return to index New query

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Transcription:

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Ls Vegas, NV 89119 (702) 455 7316 FAX (702) 455 7347 105.8.h.3 2 TITLE: HOT WORK OPERATIONS PERMIT/PLAN SUBMITTAL RENEWABLE (ANNUAL) SCOPE: Companies conducting hot work operations shall comply with Article 49 of the 2005 Clark County Fire Code and this guideline. PURPOSE: To provide standardized Clark County Fire Department requirements relating to hotwork operations, which include, cutting, welding, brazing, use of open torch, glass blowing, grinding, torch applied roofing, and similar operations where sparks, hot slag, radiant or convective heat are produced. Permit covers all hot work operations conducted by the company within unincorporated Clark County. SPECIFICATIONS AND REQUIREMENTS A permit shall be obtained from the Clark County Fire Department (CCFD), Fire & Hazard Prevention Services Division to conduct hot work operations, including but not limited to: 1. Public exhibitions and demonstrations where hot works is conducted. 2. Use of portable hot work equipment inside a structure. Exception: Work that is conducted under a construction permit issued by the building official. 3. Fixed site hot work equipment such as welding booths. 4. Hot works conducted within a Hazardous Fire Area. The Fire Department permit/plan review fee of $75.00 and a completed application form, will accompany submittal package. Package may be submitted for expedite review for an additional fee of $85.00 per hour of review and will accompany submittal package. Additional fees may apply and will be collected after review of plans. If approved, an inspection will need to be scheduled. All inspections are scheduled on our web site at http://www.accessclarkcounty.com/fire/firedept.htm Click on Online Inspection Scheduling and follow the instructions. Three submittal packages are required to be submitted to CCFD Plans Intake and shall include the items listed within the appropriate table on page 2. Revised November 20, 2008 Page 1 of 6

FIXED MOBILE COMBINATION FIXED & MOBILE A business performing all hotwork operations at a designated location within a building. 1. Provide a floor plan of the building indicating the following information: a. Location and type of hot work operations and equipment in relation to combustible materials, elevators, stairs, gangways, means of egress, building openings, or ventilation openings. A minimum of 35 separation shall be provided or approved shielding shown. b. Location, type and volume (in cubic feet) of compressed gas cylinders if used. c. Location of ventilation equipment if provided. d. Location of minimum rated 2A 20 B:C fire extinguishers or charged water hose equipped with a nozzle. Must be within 30 feet of operation and accessible without climbing stairs or ladders. 2. Provide a fire watch in accordance with Article 49 of the Clark County Fire Code 2005 edition. 3. Provide a detailed narrative operations performed in the field 4. Maintain a completed (signed) HOT WORK OPERATIONS/FIRE WATCH PROCEDURES AND SAFETY SIGN OFF SHEET at the job site. A business performing all hotwork operations at multiple locations. 1. Provide a detailed narrative operations performed in the field. 2. Provide a fire watch in accordance with Article 49 of the Clark County Fire Code 2005 edition. 3. Include the type of hot work equipment to be used. 4. Location, type and volume (in cubic feet) of compressed gas cylinders if used. 5. Maintain a completed (signed) HOT WORK OPERATIONS/FIRE WATCH PROCEDURES AND SAFETY SIGN OFF SHEET at the job site. A business performing both fixed and mobile hot work operations. FIXED 1. Provide a floor plan of the building indicating the following information: a. Location and type of hot work operations and equipment in relation to combustible materials, elevators, stairs, gangways, means of egress, building openings or ventilation openings. A minimum of 35 separation shall be provided or approved shielding shown. b. Location, type and volume (in cubic feet) of compressed gas cylinders if used. c. Location of ventilation equipment if provided. d. Location of minimum rated 2A 20 B:C fire extinguishers or charged water hose equipped with a nozzle. Must be within 30 feet of operation and accessible without climbing stairs or ladders. 2. Provide a detailed narrative operations performed in the field. MOBILE 1. Provide a detailed narrative operations performed in the field. 2. Include the type of hot work equipment to be used in the field. FIXED/MOBILE 1. Provide a fire watch in accordance with Article 49 of the Clark County Fire Code 2005 Revised November 20, 2008 Page 2 of 6

FIXED MOBILE COMBINATION FIXED & MOBILE edition. 2. Maintain a completed (signed) HOT WORK OPERATIONS/FIRE WATCH PROCEDURES AND SAFETY SIGN OFF SHEET at the job site. Revised November 20, 2008 Page 3 of 6

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Ls Vegas, NV 89119 (702) 455 7316 FAX (702) 455 7347 TITLE: SCOPE: Hot Work Operations/Fire Watch Procedures and Safety Sign off Sheet Hot work operations shall be in accordance with this guide and the requirements contained in the 2005 Clark County Fire Code PURPOSE: To provide standardized sign off sheet for the Clark County Fire Department (CCFD) requirements relating to conducting hot work operations. SPECIFICATIONS AND REQUIREMENTS Business Name of Contractor Conducting the Hot Work: Business Address of Contractor Conducting the Hot Work: Business Name for Hot Works Location Business Address for Hot Works Location CCFD Hot Work Permit Number: Dates of Hot Work Operation Conducted: Start: End: Permit Expiration Date: From: To: Conducting Hot Work Operations The use of welding, cutting and other hot work equipment shall be in accordance with Article 49 of the 2005 Clark County Fire Code. Fire watch Shall be provided during hot work activities and shall continue for a minimum of 30 minutes after the conclusion of the work. The fire watch shall include the entire hot work area. Hot work conducted in areas that Revised November 20, 2008 Page 4 of 6

include horizontal or vertical fire exposures that are not observable by a single individual shall have additional personnel assigned to fire watch to ensure that exposed areas are monitored. Individuals designated to fire watch duty shall have fire extinguishing equipment readily available and shall be trained in the use of such equipment. Individuals assigned to fire watch duty shall be responsible for extinguishing spot type fires and communicating an alarm. No other duties shall be assigned to personnel performing fire watch duty. Fire watch is not required when the hot work area has no fire hazards or combustible exposures. However, a final check is required 30 minutes after completion of operation to detect and extinguish smoldering fires. Hot work Area Hot work shall not be conducted in areas where flammable/combustible atmospheres may be present. Some examples include, but are not limited to, flammable liquids or vapors, lint, dust, or combustible storage. Appropriate shielding shall be provided to prevent ignition of combustibles materials. Hot work Equipment Shall be inspected by the operator prior to use. Equipment shall be in good repair and in proper operating condition. The Hot work Site Shall be inspected by the individual responsible for the hot work for compliance. The inspection of the hot work site shall ensure that: 1. Notify facility personnel (owner/owner representative) providing location, type of work to be performed, duration of hot work operations on a daily basis, AND FOLLOW ALL THE IN HOUSE INTERNAL HOT WORK PROCEDURES. 2. The hot work site is clear of combustibles or that combustibles are protected; 3. Exposed construction is of noncombustible materials or that combustible materials within 35 are protected; 4. Openings within 35 are protected; 5. Floors within 35 are kept clean; 6. There are no exposed combustibles on the opposite side of partitions, walls, ceilings and floors; 7. If hot work area is accessible to anyone other than operator of hot work equipment, warning sign(s) stating CAUTION HOT WORK IN PROCESS STAY CLEAR must be displayed. 8. Fire watches are assigned, equipped and trained; and 9. Fire extinguishers or charged water hose shall be verified as operable and available. 10. Actions have been taken to prevent accidental activation of suppression & detection equipment. 11. If any of these conditions cannot be met, then the hot work operation shall not be performed. Fire Watch Personnel Qualifications: 1. Be physically capable and willing to walk the building during the duration of the shift. The floor should be walked in a time period not to exceed 5 minutes, with the entire building being toured every 15 minutes. Revised November 20, 2008 Page 5 of 6

2. Walk the designated hot work areas and other fire exposures continuously during the entire hot work operations (except for breaks) and continue fire watch 30 minutes after the conclusion of the work. Replacement fire watch personnel must be provided to continue fire watch during personnel breaks. 3. Be equipped with, and able to use a bullhorn (or other loud sounding device), flashlight, remote radio and cellular phone. 4. Be capable of and willing to assist employees vacating the building in an emergency situation while utilizing a flashlight to illuminate the path of egress for evacuating employees. 5. Be trained in the use of a portable fire extinguisher and capable of extinguishing a small incipient fire utilizing a portable fire extinguisher. 6. Be instructed in and be familiar with emergency notification and evacuation procedures and capable of notifying employees of an emergency and then assisting employees to evacuate the building. All fire watch personnel on the property are responsible for responding immediately to any building where a fire condition is discovered. Upon discovery of a fire, fire watch personnel shall contact the Clark County Fire Department immediately (Dial 9 1 1), then advise all other fire watch personnel of the emergency in order to obtain their assistance in notifying and evacuating employees., (Print Name, Title, Contact Phone Number) I have read, understood, and agree to follow the fire watch procedures for hot works and will follow all the fire watch safety procedures listed above. This document shall be maintained at the job site and produced upon request. Signature Date Revised November 20, 2008 Page 6 of 6