Instruction Manual Contact Sensor

Similar documents
Instruction Manual Water Sensor

Instruction Manual Siren Alarm

Z-Wave Network Inclusion/Exclusion/Reset

Door/Window Sensor Installation Instructions

PIR sensor GR-302N GR SMART HOME

Slim Multisensor PST02-A/B/C

DCH-Z110/Z120. Function Compare DCH-Z110/DCH-Z120. Add to/remove from Z-Wave TM Network

Slim Multisensor PST02-A/B/C

Devolo home Control Door/Window Contact MT 02648

SHARP. Multi Sensor User s Guide. Model: DN3G6JA069

1126 Series Ceiling Mount PIR Motion Detector

PET IMMUNE PIR MOTION DETECTOR

IM20-ZWAVE Magnetic Contact User Guide

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

External Wireless Sounder

Intelligent Wireless GSM Alarm System

HSD-200Z Z-Wave Motion Sensor

Smoke Detector and Siren. Manual

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

status AW1 Plus WiFi Alarm System User Manual

Alarm System SECURE AS 302

SMART SMOKE DETECTOR

Tel: Fax:

SRT321 User and Installation Instructions

GSM RFID VOICE Alarm System

EWP2WIRELESS MOTION DETECTOR

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

Keys for base station: 1. MODE 2. CHANNEL 3. MAX/MIN 4. UP/(C/F) 5. SET/(AL.ON/OFF) 6. DOWN/(12/24) 7. SNOOZE 8. ALERT 9. RESET

MOBILE CALL GSM Alarm System User s Manual

OWNER S MANUAL. Remote Mobile Security System. Models: PL50 PL60

Тел: Моб: Skype: Discoverytelecom Mail: EWK2 EWK2A WIRELESS KEYFOB

View the expanded manual: GEN5

ix30 Zwave PIR Sensor

Thank. Document NO.: RD-559B

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

PRODUCT DIAGRAM PACKAGE CONTENTS

Wireless Door Detector

PRODUCT DIAGRAM PACKAGE CONTENTS

Ion Gateway Cellular Gateway and Wireless Sensors

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Smart Home Outdoor Siren

Long Range Radio Alarm Transmitter

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System


Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

System. For a better understanding of this product, please read this user manual thoroughly before using it.

1125 PIR Motion Detector

JA-63 Profi User manual

Powerley Thermostat. Installation & Operation Guide

FIB_FGBS-001 Universal Binary Sensor

SCS311 / SCS317 Installation Instructions

Dimmer Switch MH-DT411

Honeywell Temperature & Humidity Sensor with LCD

Wireless Keypad GKP-S8M

EWS3 WIRELESS INDOOR SIREN

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

2G & 3G GSM Portable PIR Alarm

IX30 - Z-Wave PIR Detector User Guide

Yale Locks. ZWave Developer User and Reference Guide. Version /30/2012

EKB3W WIRELESS LED KEYPAD

Quick start: Alarm Sound EU

FTS05 / FTS05P - Wireless Flood and Temperature Sensor, User Manual

Wireless Driveway and Intruder Alert

POP_ Smoke Detector

Long Range Radio Alarm Transmitter

Always Connected. Always Covered. Door/Window Sensor DMWD1. User Manual

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

Owner s Manual. PIR-1 IR Learner

D-TECT 3 IP. GJD260 IP Motion Detector

INTELLIGENT AXIAL FAN user's manual

Yale Locks. Z-Wave+ System Integrators Guide. Yale nextouch Sectional Mortise Keypad Lock NTM 610/615/620/625/630/635/640/645

Installation and ZONES: Operation Manual. Model: ON STI-34108

POP_ Smoke Detector

2G & 3G GSM Wireless Beam Alarm

INSTALLATION AND OPERATING MANUAL

Campers Alert TM Portable System Hunters Alert TM Portable System

Ambient Weather RC-9362 Atomic Digital Wall Clock with Temperature User Manual

CR166-RG57A6EU- 6 INFRARED WIRELESS MULTI FUNCTION REMOTE CONTROLLER OWNER S MANUAL

SMOKE User Manual. NE v2.0

Operating Manual PU-27 Control Panel

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System

10 Year Smoke Detector and Siren

Weather Light Model: BAR210 / BAR210U / BAR210A USER MANUAL. EU-Declaration of Conformity...7 FCC Statement...7 Declaration of Conformity...

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

User s guide Personal radio trigger Erik 9100

External Wireless Sounder

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

The WAVE Plus Instant Notification System for Schools and Colleges

Self-Setting Clock Radio

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Fitting instructions

Transcription:

Instruction Manual Contact Sensor Model Name:NAS-DS01Z Brand:NEO Coolcam Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual after reading Shenzhen NEO Electronics Co., LTD 1

Product Introduction Contact sensor is an intelligent security equipment that can transmit the Z-Wave network which has particular frequency. In the Z-Wave network communications, contact sensor can be connected to any Z-wave main controller. The contact sensor can send messages to the Z-wave main controller, and realize association with other devices through the Z-wave main controller. Different countries or areas, the radio frequency is different.in the communication with the Z-wave main controller, the contact sensor can send messages to the Z-wave main controller, but it can not receive messages from the Z-wave main controller. When alarm is triggered, the contact sensor sends messages to the Z-wave main controller, the Z-wave main controller will displays the current status of contact sensor, so the contact sensor can associate with other devices. Contact sensor is battery powered, is small and can be installed on the window or door easily. When the door or window is open, the contact sensor is triggered and linkage alarm realized. Technical parameters Power: CR14250 x1 Standby current: 1uA Battery life: 10 years Radio Protocol: Z-wave Radio Frequency: 868.4MHz EU; 908.4MHz US; 921.4MHz ANZ; 869.2MHz RU Wireless distance:50m Operation temperature: 0-40 Storage temperature: 0-60 Size: Contact sensor main body (L x W x H): 70mmx20mmx20mm Contact sensor deputy body (L x W x H): 40mmx11mmx11mm Technical Information Install on the door or window. Battery powered. Easily install with screws or sticker. Associate with other devices through the gateway. Compatible with any Z-Wave network. 2

Product Configuration LED light Contact sensor main body Disassemble button Contact sensor deputy body The code button Battery Sticker Screw stopper Screw Product List Contact sensor main body 1pc Contact sensor deputy body 1pc Battery 2pcs Screw 6pcs Screw stopper 6pcs Sticker 2pcs Instruction manual 1pc 3

Including Sensor (contact sensor) to Z-Wave Network The contact sensor can be included to the Z-wave network by pressing the code button. 1) Disassemble the contact sensor main body and insert the battery into the contact sensor. Make sure the device is located within the direct range of the controller. 2) Set the controller into the learning mode (see mail controller s operating manual). 3) Quickly, triple click the code button, LED light will flash for 5 times. 4) Contact sensor will be detected and included in the Z-Wave network. 5) Wait for the main controller to configure the sensor. Excluding Sensor (contact senor) from Z-Wave Network 1) Make sure the sensor is connected to power source. 2) Set the main controller into the learning mode (see main controller s operating manual). 3) Quickly, triple click the code button,led light will flash for 5 times. 4) Wait for the main controller to delete the sensor. 4

Installation Steps Contact sensor Installation Battery Installation Contact sensor Installation Option One Disassemble the contact sensor main body and take out battery, fix it on the door with screws. Disassemble the contact sensor deputy body and fix it on the corresponding door frame position Option Two Put the sticker on the bottom of contact sensor to fix it on the wall NOTE When installing the contact sensor, contact sensor deputy body must be installed on the bulge side of the Contact sensor main body. Battery Installation 5

Disassemble from here Disassemble the contact sensor Install battery Assemble the contact main body sensor main body 6

Tips When the door is closed, and the distance between the contact sensor main body and the contact sensor deputy is less than 2cm, the alarm gateway displays the door is closed perfectly. When the door is opened, the distance between the contact sensor main body and the contact sensor deputy body is more than 2cm, LED light flash and contact sensor sends messages to the alarm gateway, the alarm gateway displays the door is open and alarms. Valid distance of contact sensor is 2cm, so when install, please pay attention to the trigger surface, it is triggered by point to point. Make sure of that contact sensor is in the alarm gateway s network. The status of LED 1. When the contact sensor is triggered, LED light flashes red for 1 times. 2. When the contact sensor installs battery, LED light will flash red for 5 times. 3. Quickly, triple click the code button,add the contact sensor to the Z-WAVE network or delete contact sensor from Z-WAVE network, LED light flashes red for 5 times. 4. Press on the code button for 10 seconds, the contact sensor will be restored to factory default settings, LED light flashes red for 1 times. 5. In the normal condition, the LED light keeps being out. Associations This has the effect that when the sensor is triggered, all devices associated with the sensor will receive the relevant reports. Through an association the sensor may control another Z-Wave network devices, e.g. the alarm device, wall plug, lamp etc. The Contact Sensor supports two linkage groups: Linkage group 1 is assigned to the device status - sending the BASIC SET control frame to the associated devices having detected motion. Linkage group 2 reports relay's status to just one device, Z-Wave network's main controller by default. It's not recommended to modify settings of this association NOTE Contact Sensor linkage with other devices through Z-wave network directly, alarm gateway or Z-wave controller does not take part in such communication. 7

Restore the Sensor (contact sensor) to Factory Default Settings Reset will delete all information on the Z-Wave network or Z-Wave controller, and restore the sensor to factory default settings. 1. Remove the cover of contact sensor main body. 2. Make sure the sensor is connected to power source. 3. Press and hold the reset button for 10 seconds, LED light will flash red for 1 time. 4. Release the button. NOTE When the Contact Sensor is being restored to factory default settings, please make sure power source is connected. Battery Usage Tips Battery life of the contact sensor is approximately 10 years at factory default settings. The current battery level is displayed in the gateway. Red battery icon means the battery needs replaced. In order to avoid tamper detection, while replacing the battery, please disconnect the association of the contact sensor with other devices. Note Contact sensor is battery powered. Using batteries other than specified may result in explosion. Dispose of properly, please observe environmental protection rules. Advanced Configuration 1. Configuring the OFF Delay This configuration parameter that can be used to adjust the amount of delay before the OFF command is transmitted. This parameter can be configured with the value of 0 through 65535, where 0 means send OFF command immediately and 65535 means 65535 seconds of delay. Function: On/Off Duration. Parameter Number: 1. Parameter Size: 2 Byte Available Settings:0-65535 (in seconds, each 1s). Default Setting: 30 (s) 2. Basic Set Level Basic Set Command will be sent where contains a value when the door/window is opened or closed, the receiver will take it for consideration; for instance, if a lamp module received the Basic Set Command of which value is decisive as to how bright 8

of dim level of lamp module shall be. Function: Basic Set Parameter Number: 2 Parameter Size: 1 Byte Available Settings:0, 1-99 or 255 0 OFF, Alarm cancelling or turning a device off 1-99 or 255 ON (Binary Switch Device) Dim Level (Multilevel Switch Device) Default Setting: 99 Command Classes This Sensor(Door/Windows Detector) supports Command Classes as Below: * COMMAND_CLASS_ZWAVEPLUS_INFO (V2) * COMMAND_CLASS_VERSION (V2) * COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2) * COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1) * COMMAND_CLASS_POWERLEVEL (V1) * COMMAND_CLASS_BATTERY (V1) * COMMAND_CLASS_ASSOCIATION (V2) * COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1) * COMMAND_CLASS_WAKE_UP (V2) * COMMAND_CLASS_NOTIFICATION (V4) * COMMAND_CLASS_SENSOR_BINARY (V2) * COMMAND_CLASS_CONFIGURATION (V1) 9

Guarantee 1. The Guarantee is provided by Shenzhen NEO Electronics Co., Ltd (hereinafter Manufacture ). 2. The Manufacturer is responsible for equipment malfunction resulting from physical defects (manufacturing or material) of the device for 12 months from the date of its purchasing. 3. During the Guarantee period, the Manufacturer shall remove any defects, free of charge, by repairing or replacing. 4. In special cases, when the device cannot be replaced with the device of the same type (e.g. the device is no longer available in the commercial offer), the Manufacturer may replace it with a different device having technical parameters similar to the faulty one. Such activity shall be considered as fulfilling the obligations of the Manufacturer. The Manufacturer shall not refund money paid for the device. 5. The guarantee shall not cover: mechanical damages (cracks, fractures, cuts, abrasions, physical deformations caused by impact, falling or dropping the device or other object, improper use or not observing the operating manual); damages resulting from external causes, e.g.: flood, storm, fire, lightning, natural disasters, earthquakes, war, civil disturbance, force majeure, unforeseen accidents, theft, water damage, liquid leakage,battery spill, weather conditions, sunlight, sand, moisture, high or low temperature, air pollution damages caused by malfunctioning software, attack of a computer virus, or by failure to update the software as recommended by the Manufacturer; FCC NOTE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS OR CHANGE TO THIS EQUIPMENT. SUCH MODIFICATIONS OR CHANGE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT Shenzhen NEO Electronics Co., LTD Address: 6 TH Floor, Building No.2, Laobing Industrial Park, Tiezhai Road Xixiang, BaoAn District, Shenzhen, China. Http://www.szneo.com Tel: +86-4007-888-929 Fax: +86-755-29667746 E-mail: support@szneo.com 10