TotalPac 3 Firecyle III Deluge Remote controlled system

Similar documents
TotalPac 3 Wet pipe system c/w retard chamber

TotalPac 3 Single interlock Firecyle III Preaction Self-contained system

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

TotalPac X Firecycle III Preaction Double interlock system

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

TotalPac X Single interlock SUREFIRE system

TotalPac 3 Deluge, Electric release Self-contained system

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

TotalPac 3 Single interlock Preaction, Electric release Self-contained system

TOTALPAC2 Integrated Fire Protection System

TotalPac 3 Non interlock Preaction, Electric release Self-Contained system

FireFlex DUAL Double Interlock, Self-contained system

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. 319a. January 27, 2012

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

TECHNICAL DATA OBSOLETE

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

FireFlex 1230 Self-contained system

Deluge System. Pneumatic Release. Deluge System. Pneumatic Release

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

Operation & Maintenance Manual

Worldwide Contacts.

Model DDX Deluge Valve

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

Deluge & Preac tion Systems

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

BERMAD Fire Protection

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

Integrated Fire Protection System. Owner's Operation and Maintenance Manual

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

Instructions for Installation, Operation, Care and Maintenance

SECTION PREACTION SPRINKLER SYSTEMS

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

Becoming an Expert on Dry-pipe, Preaction, and Deluge Sprinkler Systems

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

Specification/ Data Sheet

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

Gas Station & C Store SECTION CWM Job No

TECHNICAL DATA OBSOLETE

Discontinued Product

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

TECHNICAL DATA. model c-2

(Alarm Valve) & ' ( ()& * +,, & +-,. /0-

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

CONSTRUCTION REQUIREMENTS

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

OPEN SPRINKLER SYSTEM

A. This section includes design and performance information for fire protection and suppression systems.

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

TECHNICAL DATA. Wet 26a. February 22, 2009

SECTION AUTOMATIC SPRINKLER PIPING

SECTION SPRINKLER SYSTEMS

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Environmental Health & Safety

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

SECTION SPRINKLER SYSTEMS

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Series 759 FireLock Alarm Check Valve

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION DRY-PIPE SPRINKLER SYSTEMS

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals

30.45 Electric Release PDRP-2001

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

Simple On The Outside...

DIVISION 21 FIRE SUPPRESSION

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

Transcription:

(Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical and mechanical components of the system are contained in one single unit TOTALPAC 3 Firecycle III systems are built around the Viking trim using flow control valves model J-1. Firecycle III Deluge system uses open type sprinklers and / or spray nozzles in the sprinkler piping which totally flood an area with pressurized water. A detection network is used in parallel with the open type sprinkler / nozzles system. This network is electric and may be actuated by normally closed rate compensated heat detectors, or normally open manual pull station. When the detection system operates it gives an alarm and activates the flow control valve. In addition to automatically detecting a fire and turning the system on, Firecycle III has the added ability to sense when the fire has been controlled, and automatically turn off the water flow once a preprogrammed "Soak Timer" has been satisfied. Should the fire rekindle, the releasing control panel will initiate the sequence again. This unique Firecycle III feature will repeat as long as power is available to the panel, helping to minimize water usage, water damage, and the danger of pollution to surrounding areas. The Firecycle III preaction system requires a VIKING VFR-400 releasing control panel All the valves are rated up to a maximum of 250 psi WWP (1724 kpa) max. and are available in the following diameters: 1½" (40 mm) 2" (50 mm) 3" (80 mm) 4" (100 mm) 6" (150 mm) 8" (200 mm) Standard features culus Listed & FM Approved as an assembled unit Factory assembled and tested under ISO-9001 standards Prewired to a terminal block Easy and compact installation Viking conventional trim rated at 250 psi (1724 kpa) Galvanized trim piping Serial number for easy reference Corrosion resistant cabinet with flush type handle and lock No open drain cup inside the unit numerous modular options to meet the most demanding jobsite requirements Four styles of modular air supply options Inlet & outlet hydrostatic test ports User-friendly standardized operation & installation manual Free interactive simulator 1 of 12 FM-076D-0-72D

Cabinet The TOTALPAC 3 cabinets are made of sturdy 14 gauge steel, they are available in four (4) sizes; 23" x 25" x 77" (58.4 x 63.5 x 195.6 cm) for 1½",and 2" systems, 36" x 25" x 77" (91.4 x 63.5 x 195.6 cm) for 3" and 4" system, 46" x 25" x 77" (116.8 x 63.5 x 195.6 cm) for 6" system 54" x 31" x 81" (137.2 x 78.7 x 205.7 cm) for 8" system All surfaces are rust proof coated, inside and outside, with fire red, oven baked polyester powder on phosphate base. Cabinet is provided with one or two doors, all provided with a neoprene gasket to absorb vibrations. A field wiring electrical junction boxes is integrated with the cabinet for connection of all electrical components in the trim. Pressure switches, supervisory switches, etc. are all factory wired to a terminal strip (TBA) for contractor's field wiring. Gauges to indicate air, water supply pressure and priming water pressure are all visible through clear Lexan windows. IMPORTANT: TOTALPAC 3 units are NOT designed to be installed where they will be subjected to outdoors and/or freezing conditions. Refer to environmental data for additional details. Subjecting the unit to conditions outside these limitations might tamper the normal operation of the system. Cabinet doors are provided with hinges that can easily be disassembled on site to remove the door assemblies for servicing. The cabinet assembly is pre-assembled, pre-wired, and factory tested under ISO-9001 conditions. Multiple unit installations are easily achieved by manifolding units together at their water inlets but drains shall remain separate and open. Sequence of operation (see trim diagram) In a fire condition, when the detection condition is satisfied, system releasing control panel (supplied by others) activates an alarm and energizes normally closed Solenoid valve (F2) open and normally open solenoid valve (F1) closed. Pressure is released from the priming chamber of the flow control valve (A1) to the open drain manifold faster than it is supplied through the restricted orifice (B3). The flow control valve clapper opens to allow water to flow into the system piping and alarm devices, causing the alarm pressure switch (C1) and optional water motor alarm (C2) to activate. Water will flow from all the open sprinklers and/or nozzles in the system. When the flow control valve operates, the PORV (B9) is pressurized, causing it to latch open. Water discharges until all Firecycle III detectors have reset (cooled below their set point). After all detectors have reset, the Firecycle III releasing control panel activates the soak timer, allowing the system to flow water for a pre-determined period of time. When the soak timer has elapsed, the releasing control panel de-energizes the normally closed solenoid valve (F2), allowing it to close (the normally open solenoid (F1) remains energized closed until the system is manually reset or all power (both AC and batteries) is lost). The flow control valve re-primes and closes, stopping the flow of water through the piping system. Should a Firecycle III detector go into alarm, the releasing control panel reenergizes the normally closed solenoid valve (F2) open, and the entire cycle repeats. Systems hydraulic limitations WARNING The information contained herewith is for estimation and evaluation purposes only. Its use remains the responsibility of the designer. Designers should refer to the appropriate NFPA Standards and any other applicable codes for their final design. Also refer to FireFlex Systems Inc. appropriate user manuals and to manufacturer's data sheets for additional details. Systems limitations indicated below are nominal flow limitations. Piping Equivalent Lengths w/o Piping Equivalent Lengths c/w Usage Range shut off valve shut off valve (gpm) (m.) (ft.) (m.) (ft.) GPM 1½ 0 210 8.3 27.2 8.5 27.9 272 2 0 360 11.65 38.2 11.85 38.9 272 3 100-700 19.84 65.1 23.38 76.7 762 4 200 1400 21.89 71.8 25.33 83.1 1597 6 400-3500 33.28 109.15 37.28 122.3 1597 8 750-5250 41.15 135 44.71 146.7 1597 System size (in.) Drain flow @ 250 PSIG w.p. FM-076D-0-72D 2 of 12

Standard equipment Flow control valve The Viking flow control valve is a quick opening, differential type flood valve with a spring loaded rolling diaphragm clapper. The flow control valve can be used to facilitate manual or automatic on/off control. The Viking flow control valve is an integral part of the Viking Firecycle System. The valve is held closed by system water pressure trapped in the priming chamber, keeping the outlet chamber and system piping dry. In fire conditions, when the releasing system operates, pressure is released from the priming chamber. The flow control valve clapper opens to allow water to flow into the system piping. Solenoid valve The high pressure solenoid valve is a two-way type with one inlet and one outlet. It is a packless, internal pilot operated valve, suitable for use in releasing water pressure from the priming chamber of Viking flow control valves. The solenoid valve has floating diaphragm construction, which requires a minimum pressure drop across the valve to operate properly. IN OUT Alarm pressure switch The alarm pressure switch monitors the water flow within the sprinkler piping. Should the Deluge Valve clapper opens to allow water to flow into the sprinkler piping. The alarm pressure switch will activate, indicating a water flow signal. POTTER PS10-1A Water supply control valve The water inlet control valve is a supervised, indicating butterfly valve. Purpose of this vale is to manually shutoff the preaction system. Releasing circuit disable switch The releasing circuit disable switch is used to disable the releasing solenoid. When the key is set to Disable, the releasing solenoid will be disconnected from the control panel s releasing circuit, causing a trouble signal and preventing accidental discharge during maintenance or inspection. 3 of 12 FM-076D-0-72D

Optional mechanical equipment Shut-off valve & sight glass option The Shut-off valve & sight glass option is intended to be used for applications where testing of the system operation without filling the sprinkler piping network is desirable and where it is critical that all functions of the preaction system be tested under actual discharge conditions. Examples of such applications are freezers, ovens, museums, data processing and other hazards where the possibility of water leaking from the piping system is to be avoided at all costs. Warning: Shut-off valve & sight glass option is not available on 8" systems. Fire department connection The fire department connection option consists of a grooved tee fitting installed at the outlet of the deluge valve (A1). An access hole of the proper diameter is factory pre-drilled on the side of the TOTALPAC 3 enclosures for connection of the piping going to the fire department connection. Note: The fire department connection hardware itself (drain, Siamese, etc.) is NOT provided with this option and shall be provided by the installing contractor. Refer to NFPA- 13 Standard for additional information about the equipment layout and installation. Warning: Shut-off valve is not available combined with Fire department connection on 6" systems. Warning: Fire department connection is not available on 8" systems. Main Drain Valve (D3) Sight Glass Assembly (D5) Supervised Shut-off Valve (D4) Grooved Tee Fitting with Coupling & Cap To Fire Dep't Connection (hardware by Contractor) Point flash light here Supervised Water Supply Control Valve (D1) FM-061H-0-79B FM-061H-0-78B FM-076D-0-72D 4 of 12

Optional mechanical equipment (continued) Semi and full flanged option When required by the user, TOTALPAC 3 units can be provided in either a semi-flanged of full flanged configuration. The semi flanged option provides flanged fittings only on the water inlet pipe (side needs to be specified at the time of order) and on the system riser outlet. The drain manifold is then provided with a threaded end that also needs to have its side specified (left or right). The rest of the fittings are the same as usual with the main components being provided in the standard grooved -grooved configuration. The full flanged option is the same as above but goes a step further with the main components being also provided with a flanged-flanged configuration. When provided, the face of the flanges will always be situated 6 inches from the outside face of the mounting base or cabinet surface. On skid units, the surface of the flange on the outlet riser will always be 6 inches above the dimension shown on the dimensional data of the system ordered. OSHPD option Pre-approved construction, under OSP-0341-10, using specific components. Flanged fitting outside cabinet (when provided) Threaded end Field Connection to Open Drain (specify side) Flanged fitting outside cabinet (when provided) Field connection to Water Supply (specify side) FM-061H-0-208B 5 of 12 FM-076D-0-72D

Details & field wiring diagrams Cabinet with main components - Configuration without releasing control panel Cable Entry Release Solenoid Disconnect Switch Junction box TBA & TBB Riser Outlet to Sprinklers Network Straight Through Flow Control Valve Water Supply Control Valve Drain Outlet (either side) Water Inlet (either side) FM-061H-0-192B FM-076D-0-72D 6 of 12

Trim diagram FIELD CONNECTION TO SPRINKLER PIPING NETWORK B9 C1 B10 D3 A1 B8 C2 B5 B11 B7 D1 B6 B13 FIELD CONNECTION TO OPEN DRAIN (on both sides) B12 B3 B4 B2 B1 FIELD CONNECTION TO WATER SUPPLY (on both sides) TotalPac Base (shown without enclosure) CONTRACTOR'S HYDROSTATIC TEST PORT (water supply side) Trim Components: A2 Flow control valve B1 Priming valve B2 Strainer B3 1/8" Restricted orifice B4 Spring loaded check valve B5 Alarm test valve B6 Flow test valve B7 Drip check valve B8 Drain check valve B9 Pressure operated relief valve (PORV) B10 Emergency release valve B11 Priming pressure water gauge & valve B12 Water supply pressure gauge & valve B13 Clapper check valve C1 Alarm pressure switch C2 Connection to water motor gong (strainer supplied by contractor) D. Valve: D1 Water supply control valve D3 Main drain valve F1 N.O. Solenoid valve 24Vdc F2 N.C. Solenoid valve 24Vdc 7 of 12 FM-076D-0-72D

Field wiring diagrams, Single interlock Electric, Self-Contained: CHICAGO OPTION OPTIONAL LOS ANGELES OPTION WATER FLOW EOL MAIN VALVE EOL SOLENOID VALVE BYBASS SWITCH SUPERVISORY EOL 24 VDC Needed for keyswitch LEDs operation SOLENOID VALVE SHUT-OFF VALVE EOL 13 14 15 16 17 18 MAIN VALVE OPTIONAL TBA 9 10 11 12 TBC 1 SHUT-OFF VALVE 1 2 3 4 5 6 7 8 2 3 4 5 6 C NO NC C NO NC WATER FLOW SWITCH MAIN VALVE SUPV SWITCH 19 20 21 22 23 24 25 26 S N.C. SOLENOID VALVE (see table below for ratings) LED POWER DISCHARGE BYPASS SWITCH S N.O. SOLENOID VALVE (see table below for ratings) SHUT-OFF VALVE SUPV SWITCH NOTE: MAIN VALVE SUPV SWITCH SHUT-OFF VALVE SUPV SWITCH Contacts provided for connection to the building's central Fire Alarm Panel. NOTES: All devices are factory wired. All devices are shown in their normal supervisory state. Contacts are rated: Pressure switches: 2A, 30VDC 10A, 125/250VAC Supervisory switches: 0.5A, 125VDC 0.25A, 250VDC 5A, 1/6HP, 125/250VAC Use dry contacts with power limited circuits only. EOL devices (not included) must be compatible with the Release Control Panel used. FM-061H-0-94B Note: This unit has been provided without the Integrated Release Releasing control panel. Due to Listings and Approvals specific to the Firecycle System, no other release releasing control panel other than the Firecycle III Model VFR-400 Releasing control panel can be used with this unit. Use of any other releasing control panel is not recommended and will void the unit's Listings & Approvals and may prevent the system from operating normally. FM-076D-0-72D 8 of 12

Dimensions Figure 1 Cabinet dimensions: D E P TBA, TBB & TBC Q TBB TBA & TBC F CONTROL PANEL (except for Remote Controlled Unit) SPRINKLER RISER SCH.40 GROOVED OUTLET CONTROL PANEL SPRINKLER RISER SCH.40 GROOVED OUTLET ØB OPTIONAL SHUT-OFF VALVE OPTIONAL FIRE DEP'T CONNECTION OUTLET (DRILLED ONLY WHEN ORDERED) S (W) R (V) J L N DRAIN - SCH.40 GROOVED OUTLET N ØC T ØA M WATER INLET SCH.40 GROOVED OUTLET M K H G U FM-061H-0-129A Dimensions are nominal and may vary ±¼". Dimensions V and W are with the optional Fire Department Connection System Size A B C D E F G H J K L M N P Q R S T U V W 1½" 2" 1½" 2" 23 25 77¼ 4 8¾ 11½" 13¾ 3¾ 2¾ 2¾ 8 11½" 37½" 44¾" 47½" 27 43 50¼ 2" 2" 2" 2" 23 25 77¼ 4 8¾ 11½" 13¾ 3¾ 2¾ 2¾ 8 11½" 37¾" 45 47¾" 27 43¼ 50½ 3" 4" 3" 2" 35¾ 25 77¼ 4 10 11½" 13¾ 3¾ 2¾ 2¾ 11¾ 11½" 44 47¾" 51¼ 39¾" 51 54¾" 4" 4" 4" 2" 35¾ 25 77¼ 4 10 11½" 13¾ 3¾ 2½ 2½ 12 11½" 48½" 53 59 39¾" 56½ 61 6" 6" 6" 2" 46 25 77¼ 4 11 11½" 13¾ 3¾ 5¼ 5¼ 17¾ 11½" 59¼ 65 70½" 50 70¼ n/a 8" 8" 8" 2" 54 31 81¼ 4 12 13¼ 17 3¾ 9 6¾ 27 13¼ 70 75½ n/a 58 n/a n/a SYSTEMS WEIGHTS Cabinets without control panel System Description Weight (lbs) Weight (Kg) 1½" Preaction cabinet unit 460 209 2" Preaction cabinet unit 465 211 3" Preaction cabinet unit 740 336 4" Preaction cabinet unit 755 342 6" Preaction cabinet unit 1035 469 8" Preaction cabinet unit 1485 674 9 of 12 FM-076D-0-72D

Figure 2 Anchoring dimensions: Figure 3 Cabinet clearance dimensions A B min. 5" B ¾" TOP VIEW TOTALPAC UNIT TYPICAL MECHANICAL ROOM 1" FRONT FM-061H-0-128A System Size A B 1½ 25 15" 2 25 15" 3 37¾ 15" 4 37¾ 15" 6" 48" 15" 8" 56" 21" B min. FM-061H-0-130A System Size A min. A B 1½ 24" 12 2 24" 12 3 24" 12 4 24" 12 6" 24" 12 8" 32" 12 Figure 4 Knockouts detail Top of Cabinet High voltage 2½" Low voltage 8½" 3¾" 2½" Typ. 3" FM-061H-0-68B-12 FM-076D-0-72D 10 of 12

Figure 5: Open drain details for single unit: (See dimensions in table below) TotalPac Unit Shown Without Front Door Unit Drain Pipe (dia. = C) Air Gap Water Supply Pipe 4'' min. B A Single Unit Detail Drain Pipe (pipe diameter per drain flow calculation) FM-061H-0-139A Figure 6: Open drain details for multiple units: (See dimensions in table below) 12'' min. Water Supply Pipe (Can Be Manifolded) TotalPac Unit Shown Without Front Door TotalPac Unit Shown Without Front Door Unit Drain Pipe (dia. = C) DO NOT MANIFOLD! Typical Air Gap B 4'' min. A Drain Collector running between wall and units (pipe diameter per drain flow calculations) Multiple Units Detail FM-061H-0-140A Dimension table Unit Size: 1½" 2" 3" 4" 6" 8" A 8¾" 8¾" 10" 10" 11" 12" B 13¾" 13¾" 13¾" 13¾" 13¾" 17" C 2" 2" 2" 2" 2" 2" Notes: 1. Supply and drain pipes can be connected on either sides of cabinet. 2. All pipes and fittings should meet applicable codes. 3. Actual drain collector diameter shall be determined with detailed hydraulic calculations and is the responsibility of the system designer. 11 of 12 FM-076D-0-72D

1935, Lionel-Bertrand Blvd. Boisbriand QC Canada J7H 1N8 Tel.: 450-437-3473 Fax: 450-437-1930 Toll Free: 866-347-3353 Email: info@fireflex.com Web: www.fireflex.com FM-076D-0-72D 12 of 12