SUBMITTAL. Project. Cross Creek Elementary School. Date. Thursday, July 23, 2015

Similar documents
TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

RECORD SUBMITTAL COVER SHEET

MACH N-407 Heat Pump Air-Cooled Chiller

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

48PGD/E/F/L/M/N PG20-28

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

MAC N-407 Air-Cooled Chiller

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PAJ3. Product Specifications

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

50TM COMBINATION HEATING/COOLING UNITS

PAR5. Product Specifications

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Water-Cooled Self-Contained Units

Advance Release September 2009

VertiCool Aurora Engineering Guide

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

MAC-120HE-03 Air-Cooled Chiller

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Advance Product Data

Commercial High-Efficiency Condensing Units

50TM TFF COMBINATION HEATING/COOLING UNITS

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

RGE 13 A T - 1 A

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Advance Product Data

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

48TM GAS HEATING/ELECTRIC COOLING UNITS

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

FCC Fan-Coil Units High-Performance, Vertical

Submittal Data Performance Data Electrical Data

13 GEP A L P - 1 A

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

WJH4 Product Specifications

Split System Heat Pumps

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

BAC / BHC SERIES 7-1/2 to 20 Ton Air Handlers

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12

Commercial High-Efficiency Condensing Units

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

C13-Series Engineering Guide

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

PACKAGE AIR CONDITIONER

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

General Description. Operation

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

Product Data. Fig. 1 - Unit 50VR -A

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

VariCool VAV Engineering Guide

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

We are pleased to submit the following equipment for your approval on the above project:

Call us today! (800)

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Transcription:

SUBMITTAL Project Cross Creek Elementary School Date Thursday, July 23, 2015

Table Of Contents FCU-72 3 Unit Report 4 Performance Summary 6 Acoustic Summary 10 Certified Drawing 12 Guide Specifications 16 Unit Feature Sheet 21 Commercial Split Systems Builder 1.36 Page 2 of 22

FCU-72 FCU-72 FCU-72 Submittal Cover Sheet Unit Report Performance Summary Report Acoustic Summary Certified Drawings Guide Specifications Feature Sheet Commercial Split Systems Builder 1.36 Page 3 of 22

Unit Report Unit Report For FCU-72 Outdoor Unit Parameters Unit Quantity: 1 Unit Model: 38APD Unit Size: 30 Tons Voltage: 460-3-60 V-Ph-Hz Circuit: Dual Circuit Indoor Unit Parameters Unit Model: 40RUA Unit Size: 30 Tons No. of Splits: 2 Voltage: 460-3-60 V-Ph-Hz 38AP units are not designed for Refrigeration Duty. Unit operational range should be reviewed to ensure that operation at full and part load conditions with Saturated Suction Temperatures at or below 30F are avoided. Operation below 30F SST may result in ice build-up on evaporator coil resulting in liquid flood-back and possible compressor failure. Return/Mixed Air temperature should not be below 55F. If the customer requires differently, please contact engineering. System Parameter System Quantity: 1 Refrigerant Type: PURON Compressor Quantity: 1 (Circ A), 1 (Circ B) Compressor Type: Scroll Std. Capacity Steps: 50, 100 Std. Min. Outdoor Temp(Cooling): 32.0 F No. of Outdoor fans: 2 Outdoor Unit Dimensions and Weight Unit Length: 7' 4.2'' Unit Width: 3' 4.3'' Unit Height: 6' 1.1'' Unit Operating Weight: 1264 lb Indoor Unit Dimensions and Weight Unit Length: 8' 4.5'' Unit Width: 2' 8.6'' Unit Height: 5' 6.6'' Unit Shipping Weight: 1062 lb Unit Operating Weight: 1062 lb Warranty Information Outdoor (Note: for US & Canada only) First Year - Parts Only (Standard) Complete Unit 1yr Labor for Outdoor Unit 5yr Compressor Parts/Labor for Outdoor Unit Warranty Information Indoor (Note: for US & Canada only) First Year - Parts Only (Standard) NOTE: Please see Warranty Catalog 808-218 for explanation of policies and ordering methods. An uncoated Novation condenser coil was selected for this product. This is based on an installed location with postal code: 31792 and a non-corrosive localized environment. Ordering Information Part Number Description Quantity Base Unit - Outdoor Commercial Split Systems Builder 1.36 Page 4 of 22

Unit Report For FCU-72 38APD03064-10020 1 Base Unit Standard Line Length 1 Single Point Power, Terminal Block 1 Std Packaging 1 Scrolling Marquee 1 MCHX Accessories 38AP-900---003 Security Grilles/Hail Guards for Outdoor Unit 1 Base Unit - Indoor 40RUAA30T2A6-0A0A0 1 Base Unit Std Static, Std Eff Motor/ Medium Drive 1 Cabinet Paint - None 1 2-Speed Fan Controller (VFD) 1 Accessories 33ZCSPTCO2LCD-01 CO2/Space Temp. Sensor with LCD DIsplay and No Override for 1 Indoor Unit CASUBASE002A00 Floor Mount Base (Subbase) for Indoor Unit 1 CRDISKIT001A00 2 Speed VFD display kit for Indoor Unit 1 CAECOMZR012A00 Economizer - temperature dry bulb controlled - Ultra LOW LEAK for Indoor Unit 1 Commercial Split Systems Builder 1.36 Page 5 of 22

Performance Summary Performance Summary For FCU-72 System: 38APD030/40RUA030 Circuit: Dual Circuit System Quantity: 1 Altitude: 0.0 ft EER @ ARI Conditions: 10.8 EER @ Ambient Conditions: 10.7 Suction Line Loss: 2.0 F Condensing unit is rated in accordance with ARI 365. Liquid and Suction Line Sizing Pipe Length Liquid Line Size Suction Line Size 0-25 5/8 (A), 5/8 (B) 1 1/8 (A), 1 1/8 (B) 26-50 5/8 (A), 5/8 (B) 1 3/8 (A), 1 3/8 (B) 51-75 5/8 (A), 5/8 (B) 1 3/8 (A), 1 3/8 (B) 76-100 5/8 (A), 5/8 (B) 1 3/8 (A), 1 3/8 (B) 101-125 5/8 (A), 5/8 (B) 1 5/8 (A), 1 5/8 (B) 126-150 5/8 (A), 5/8 (B) 1 5/8 (A), 1 5/8 (B) 151-175 7/8 (A), 7/8 (B) 1 5/8 (A), 1 5/8 (B) 176-200 7/8 (A), 7/8 (B) 1 5/8 (A), 1 5/8 (B) Do NOT exceed 200 ft max linear separation or 75 ft vertical liquid lift. Oil management is critical on split systems for compressor reliability. Refrigerant circuit warranty may be void beyond these limits. Dual suction riser may be required, refer to PD. Outdoor Unit Parameters Unit Quantity: 1 PartNumber: 38APD03064-10020 Unit Model: 38APD Unit Size: 30 Tons Voltage: 460-3-60 V-Ph-Hz Clg Ent Air DB: 95.0 F Outdoor Electrical Data Unit Voltage: 460-3-60 V-Ph-Hz Unit#1 MCA: 67.1 Amps Unit#1 MOCP: 90.0 Amps Compressor Power: 31.80 kw Voltage Range Min: 414 V Voltage Range Max: 506 V Compressor RLA: 26.9/26.9 Compressor LRA: 179/179 Compressor Quantity: 1 (Circ A), 1 (Circ B) Fan Motors Qty: 2 Notice: Outdoor unit elect. data is based on 460-3-60 Indoor Unit Parameters PartNumber: 40RUAA30T2A6-0A0A0 Unit Model: 40RUA Unit Size: 30 Tons Coil Rows: 4 No. of Splits: 2 Voltage: 460-3-60 V-Ph-Hz Actual Airflow: 10360.0 CFM Standard Airflow: 10360.0 CFM Total Clg Cap.(Gross): 377.7 MBH Sensible Clg Cap.(Gross): 281.4 MBH Ent Air DB: 79.1 F Ent Air WB: 65.4 F Commercial Split Systems Builder 1.36 Page 6 of 22

Performance Summary For FCU-72 Ent Enthalpy: 30.22 BTU/lb Lvg Air DB: 53.9 F Lvg Air WB: 53.3 F Lvg Enthalpy: 22.12 BTU/lb Coil Bypass Factor: NA 38AP units are not designed for Refrigeration Duty. Unit operational range should be reviewed to ensure that operation at full and part load conditions with Saturated Suction Temperatures at or below 30F are avoided. Operation below 30F SST may result in ice build-up on evaporator coil resulting in liquid flood-back and possible compressor failure. Return/Mixed Air temperature should not be below 55F. If the customer requires differently, please contact engineering. Indoor Supply Fan ***Using 2-Speed Fan Controller (VFD) Indoor Unit External Static: 1.00 in wg Economizer Loss: 0.11 in wg Grille Loss: 0.00 in wg Plenum Loss: 0.00 in wg Acc. Heating Loss: 0.00 in wg Total Ext Static: 1.11 in wg Fan Speed: 862 RPM Fan Power: 6.00 BHP Fan Motor Max: 10.00 BHP Fan Motor FLA: 16.0 Amps Motor and Medium Static Drive Required. Selected Medium Static Drive Range: 798-984 Indoor Electrical Data Unit Voltage: 460-3-60 V-Ph-Hz Unit MCA: 20.0 Amps Unit MOCP: 35.0 Amps Notice: Indoor unit elect. data is based on 460-3-60 FIOPS and Accessories Information FIOPS Scrolling Marquee 1 MCHX Accessories Security Grilles/Hail Guards for Outdoor 1 Unit Quantity Quantity Liquid line check valve(s) prevent charge migration to compressor. These valves may be required for certain applications, refer to PD. Acoustic Information A-Wgt Outdoor Sound Power Level: 94.9 dba Acoustic Notes: 1. The acoustic center of the unit is located at the geometric center of the unit. 2. All estimated sound power levels, db re 1 Pico watt should not be guaranteed or certified as being the actual sound power levels. Advanced Accoustics Parameters 1. Unit height above ground: 1.0 ft 2. Horizontal distance from unit to receiver: 20.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal dist. from obstruction to receiver: 0.0 ft 6. Horizontal dist. from unit to obstruction: 0.0 ft Commercial Split Systems Builder 1.36 Page 7 of 22

Performance Summary For FCU-72 Detailed Acoustics Information Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall Sound Power Levels at Unit's Acoustic Center (Lw), db 76.6 96.4 93.3 92.3 92.6 89.8 86.6 83.6 80.1 100.7 A-Wgted Sound Power Levels at Unit's Acoustic Center (LwA), dba 37.2 70.2 77.2 83.7 89.4 89.8 87.8 84.6 79.0 94.9 Sound Press. Levels at Dist. Specified above (Lp), db 52.4 72.2 69.1 68.1 68.4 65.6 62.4 59.4 55.9 76.5 A-Wgted Sound Press. Levels at Dist. Specified above (LpA), dba 13.0 46.0 53.0 59.5 65.2 65.6 63.6 60.4 54.8 70.7 Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. An uncoated Novation condenser coil was selected for this product. This is based on an installed location with postal code: 31792 and a non-corrosive localized environment. Commercial Split Systems Builder 1.36 Page 8 of 22

Performance Summary For FCU-72 4 40RUA030 with Standard Capacity Coil 1100RPM Static Pressure (in. wg.) 3 2 1 1000RPM 900RPM 800RPM 700RPM 600RPM 500RPM 400RPM RP SC 5.00 BHP 7.50 BHP 10.00 BHP 0 0 2 4 6 8 10 12 14 16 18 Airflow (CFM- thousands) RPM = 862 BHP = 6.00 Maximum RPM = 1200 Maximum HP = 10.00 Shaded Area - Recommended Operating Range SC - System Curve RP - Rated Point MP - Minimum Point Commercial Split Systems Builder 1.36 Page 9 of 22

Acoustic Summary Acoustic Summary For FCU-72 Outdoor Unit Parameters: Tag Name: FCU-72 Unit Model: 38APD Unit Size: 30 Tons System Type: Dx Cooling Only Refrigerant Type: PURON Compressor Quantity: 1 (Circ A), 1 (Circ B) Compressor Type: Scroll Advanced Accoustics Parameters 1. Unit height above ground: 1.0 ft 2. Horizontal distance from unit to receiver: 20.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Overall Sound Power Levels at Unit's Acoustic Center (Lw), db 76.6 96.4 93.3 92.3 92.6 89.8 86.6 83.6 80.1 100.7 A-Wgted Sound Power Levels at Unit's Acoustic Center (LwA), dba 37.2 70.2 77.2 83.7 89.4 89.8 87.8 84.6 79.0 94.9 Sound Press. Levels at Dist. Specified above (Lp), db 52.4 72.2 69.1 68.1 68.4 65.6 62.4 59.4 55.9 76.5 A-Wgted Sound Press. Levels at Dist. Specified above (LpA), dba 13.0 46.0 53.0 59.5 65.2 65.6 63.6 60.4 54.8 70.7 Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Acoustic Note: 1. Estimated Sound Power levels - db re: 1 picowatt 2. Estimated Sound Pressure levels - db re: 20 micropascal 3. Estimated sound levels given above are assumed to originate at the acoustic center of the unit. The acoustic center of the unit is located at the projection of the condensing unit's geometric center of its base. 4. Sound power levels shown above were determined in accordance with ARI standard 370 for large outdoor refrigeration and air conditioning equipment. 5. Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the ARI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Indoor Unit Parameters: Tag Name: FCU-72 Unit Model: 40RUA Unit Size: 30 Tons System Type: Dx Cooling Only External Static Pressure: 1.11 in wg Fan Speed: 862 RPM Fan BHP: 6.00 BHP Commercial Split Systems Builder 1.36 Page 10 of 22

Acoustic Summary For FCU-72 Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4k 8k Total Sound Power,dB NA 104.7 100.7 96.7 97.7 91.7 89.7 85.7 NA 107.4 A-Weighted Sound Power, dba NA 78.5 84.6 88.1 94.5 91.7 90.9 86.7 NA 98.5 Notes: 1. The above estimated duct sound power levels are based upon the ASHRAE calculation approach from the ASHRAE 1987 HVAC Systems and Applications handbook, Chapter 52. 2. Since this data is calculated, these sound power levels may be different than the actual sound power levels. 3. The acoustic center of the units is located at the geometric center of the unit. Commercial Split Systems Builder 1.36 Page 11 of 22

Certified Drawing Certified Drawing for FCU-72 Commercial Split Systems Builder 1.36 Page 12 of 22

Certified Drawing for FCU-72 Commercial Split Systems Builder 1.36 Page 13 of 22

Certified Drawing for FCU-72 DIMENSIONS (cont.) PLENUM, RETURN-AIR GRILLE, AND SUBBASE ACCESSORIES UNIT SIZE 28, 30 40RU NOTE: Dimensions in [ ] are millimeters. C09498 19 Commercial Split Systems Builder 1.36 Page 14 of 22

Certified Drawing for FCU-72 DIMENSIONS (cont.) ECONOMIZERACCESSORY UNIT SIZES 07-12 40RU UNIT SIZES 14-25 UNIT SIZES 28, 30 NOTE: 1. For horizontal unit applications, economizer can be attached to end of unit opposite duct connections. 2. Dimensions in [ ] are millimeters. C09488 22 Commercial Split Systems Builder 1.36 Page 15 of 22

Guide Specifications Guide Specification for FCU-72 GUIDE SPECIFICATIONS 38APD03064-10020 HVAC Guide Specifications Commercial Air-Cooled Condensing Units with Puron Refrigerant (R-410A) Size: 030 Part 1: General SYSTEM DESCRIPTION 1.01. Outdoor-mounted, air-cooled condensing unit with Puron refrigerant (R-410A) suitable for on-the-ground or rooftop installation. The 38APD unit shall have two independent refrigeration circuits and shall consist of two, four, five or six rotary scroll compressors. Unit shall have air-cooled coils, propeller- type condenser fans, a control box, and shall discharge condenser air vertically upward as shown on certified drawings. Unit shall be used in refrigeration circuit with a central station air-handling unit or direct-expansion coils. QUALITY ASSURANCE 1.01. Unit performance shall be rated in accordance with AHRI Standard 365, latest edition (U.S.A). 1.02. Unit construction shall comply with latest edition of ASHRAE 15 Safety Code, UL 1995, and ASME applicable codes (U.S.A. codes). 1.03. Unit shall be manufactured in a facility registered to ISO 9001 Manufacturing Quality Standard. 1.04. Base unit shall be constructed in accordance with UL standards and CSA. 1.05. Unit cabinet shall be capable of withstanding 500-hour salt-spray exposure per ASTM B117 (scribed specimen). 1.06. Design pressure shall be 650 psig (4482 kpa). 1.07. Unit shall be functional checked at the factory. DELIVERY, STORAGE, AND HANDLING 1.01. Unit shall be shipped as single package and shall be stored and handled per unit manufacturer's recommendations. WARRANTY (FOR INCLUSION BY SPECIFYING ENGINEER) Part 2: Products EQUIPMENT 2.01. General: A. Factory assembled, single-piece, air-cooled condensing unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, compressors, nitrogen holding charge, and special features required prior to field start-up. 2.02. Unit Cabinet: A. Cabinet shall be galvanized steel casing with a baked enamel powder or pre-painted finish. B. Cabinet shall be capable of withstanding 500-hr salt spray test in accordance with ASTM (U.S.A.) B-117 standard. C. Control box access panels shall be hinged for service access. D. Lifting holes shall be provided to facilitate rigging. 2.03. Fans: A. Condenser fans shall be direct-drive propeller type, discharging air vertically upward. B. All condenser fan motors shall be totally enclosed 3-phase type with permanently lubricated ball bearings, class F insulation and internal, automatic-reset thermal overload protection or manual reset calibrated circuit breakers. Commercial Split Systems Builder 1.36 Page 16 of 22

Guide Specification for FCU-72 C. Shafts shall have inherent corrosion resistance. D. Fan blades shall be statically and dynamically balanced. E. Condenser-fan openings shall be equipped with PVC-coated steel wire safety guards. 2.04. Compressors: A. Compressors shall be rotary scroll. B. Operating oil charge and a crankcase heater control oil dilution. C. Compressors shall be mounted on two rails having rubber in shear vibration isolators. D. Staging of compressors shall provide unloading capability. E. Compressor motors shall be cooled by refrigerant gas passing through motor windings and shall have either internal line break thermal and current overload protection or external current overload modules with compressor temperature sensors. 2.05. Condenser Coils: A. Coil shall be air-cooled microchannel heat exchanger (MCHX) and shall have a series of flat tubes containing a series of multiple, parallel flow microchannels layered between the refrigerant manifolds. Microchannel coils shall consist of a twopass arrangement. Coil construction shall consist of aluminum alloys for the fins, tubes and manifolds in combination with a corrosion-resistant coating on the tubes. B. Tubes shall be cleaned, dehydrated, and sealed. C. Assembled condenser coils shall be leak tested and pressure tested at 650 psig (4482 kpa). 2.06. Refrigeration Components: A. Refrigeration circuit components shall include liquid line temperature relief device, pressure transducers, liquid line shutoff valve, suction shutoff valve, suction line accumulators, nitrogen holding charge, and compressor oil. B. Standard line length (0-100 ft) C. Long line length check valves are required for liquid line installation on all linear line length applications of more than 100 ft (30.5 m) to prevent liquid migration during unit shutdown. For any 025-030 size dual circuit unit application where evaporator is located higher than the condensing unit, check valves are required for linear line length above 55 ft (16.8 m). D. Units shall include one factory-installed suction line accumulator for each refrigerant circuit. 2.07. Controls and Safeties: A. Unit ComfortLink controls shall include: 1. Scrolling marquee display module shall be used for accessing condensing unit information, reading sensor values, and testing the condensing unit. The scrolling marquee display is a 4-key, 4-character, 16-segment LED (light-emitting diode) display. Eleven mode LEDs shall be located on the display as well as an Alarm Status LED. The display shows all of the ComfortLink control codes (with 60-character expandable clear language), plus set points, time of day, temperatures, pressures, and superheat. Additional information can be displayed all at once with the accessory Navigator display. 2. Carrier Comfort Network (CCN) system capability. 3. Unit control with standard pressure transducer, discharge pressure transducer and suction temperature thermistors. 4. Current alarm list and alarm history list on display. 5. Automatic compressor lead/lag control. 6. Service run test capability. 7. Compressor minimum run time (3 minutes) and minimum off time (3 minutes). 8. Service diagnostic mode. 9. Self-contained low voltage control circuit. 10. Cycle condenser fans to maintain proper head pressure control. 11. Capacity control with staging compressors. 12. Alarm relay output to indicate when unit is in alarm condition. B. Minimum unit safety devices shall include: 1. Solid-state compressor lockout to provide optional reset capability at the space thermostat if any of the following safety devices trip and shut off compressor. a. Compressor lockout protection for internal or external overload. Commercial Split Systems Builder 1.36 Page 17 of 22

Guide Specification for FCU-72 b. Low pressure protection. c. High pressure protection (high pressure switch or internal). d. Compressor reverse rotation protection. e. Loss of charge protection. f. Low suction superheat protection. g. Short cycle protection. h. Suction and discharge pressure transducers. i. Circuit breakers or fuses for short circuit protection of compressors. 2.08. Operating Characteristics: A. The capacity of the condensing unit shall meet or exceed Btuh ( kw) at a suction temperature of F ( C). The power consumption at full load shall not exceed Btuh( kw). B. The combination of the condensing unit and the evaporator or air handling unit shall have a total net cooling capacity of Btuh ( kw) or greater at conditions of cfm ( L/s) entering-air temperature at the evaporator at F ( C) wet bulb and F( C) dry bulb, and air entering the condensing unit at F( C). C. The system shall have an Energy Efficiency Ratio (EER) of Btuh/watt or greater at standard AHRI conditions. 2.09. Electrical Requirements: A. All unit power wiring shall enter unit cabinet at a single location. Unit shall be provided with a XL starter and a terminal block. 2.10. Special Features: A. Security Grilles/Hail Guards: 1. Units will be supplied with field-installed louvered, sheet metal panels which securely fasten to the unit to provide condenser coil protection against hail and physical damage. GUIDE SPECIFICATIONS 40RUAA30T2A6-0A0A0 Commercial Packaged Air-Handling Unit HVAC Guide Specifications Size: 30 Part 1: GENERAL SYSTEM DESCRIPTION 1.01. Indoor, packaged air-handling unit for use in commercial split systems. Unit shall have a multi-position design and shall be capable of horizontal or vertical installation on a floor or in a ceiling, with or without ductwork. (Only vertical units are to be applied without ductwork.) 1.02. Unit with direct-expansion coil shall be used in a refrigerant circuit with a matching air-cooled condensing unit. Unit with chilled water coil shall be used in a chilled water circuit. QUALITY ASSURANCE 1.01. Coils shall be designed and tested in accordance with ASHRAE 15 Safety Code for Mechanical Refrigeration (U.S.A.), latest edition. 1.02. Unit shall be constructed in accordance with ETL (U.S.A.) and ETL, Canada, standards and shall carry the ETL and ETL, Commercial Split Systems Builder 1.36 Page 18 of 22

Guide Specification for FCU-72 Canada, labels. 1.03. Unit insulation and adhesive shall comply with NFPA-90A (U.S.A.) requirements for flame spread and smoke generation. Insulation shall contain an EPA-registered immobilized antimicrobial agent to effectively resist the growth of bacteria and fungi as proven by tests in accordance with ASTM standards G21 and 22 (U.S.A.). 1.04. Unit shall be manufactured in a facility registered to the ISO 9001:2000 manufacturing quality standard. 1.05. Direct-expansion and chilled water coils shall be burst and leak tested at 435 psi (2999 kpa). DELIVERY AND STORAGE 1.01. Units shall be stored and handled per manufacturer s recommendations. Part 2: Products EQUIPMENT 2.01. Indoor mounted, draw-thru, packaged air-handling unit that can be used in a suspended horizontal configuration or a vertical configuration. Unit shall consist of forward-curved belt-driven centrifugal fan(s), motor and drive assembly, pre-wired fan motor contactor, factory-installed refrigerant metering devices (direct-expansion coil units), cooling coil, 2-in. (51-mm) disposable air filters, and condensate drain pans for vertical or horizontal configurations. 2.02. Base Unit: A. Cabinet shall be constructed of mill-galvanized steel. B. Cabinet panels shall be fully insulated with 1/2-in. (12.7-mm) fire-retardant material. Insulation shall contain an EPAregistered immobilized antimicrobial agent to effectively resist the growth of bacteria and fungi as proven by tests in accordance with ASTM standards G21 and 22 (U.S.A.). C. Unit shall contain non-corroding condensate drain pans for both vertical and horizontal applications. Drain pans shall have connections on right and left sides of unit to facilitate field connection. Drain pans shall have the ability to be sloped toward the right or left side of the unit to prevent standing water from accumulating in pans. D. Unit shall have factory-supplied 2-in. (51 mm) throwaway-type filters installed upstream from the cooling coil. Filter access shall be from either the right or left side of the unit. 2.03. Coils: A. DX coil is 4-row and consists of copper tubes with sine-wave aluminum fins bonded to the tubes by mechanical expansion. Suction and liquid line connections or supply and discharge connections shall be made on the same side of the coil. 1. Direct-expansion coils shall feature factory installed thermostatic expansion valves (TXVs) for refrigerant control. The TXVs shall be Puron R-410A compatible and capable of external adjustment. Direct-expansion heat pump coils shall have a factory-installed bypass line and check valve assembly around the TXVs to allow liquid flow from the coil to the outdoor unit during the heating mode. Coil tubing shall be internally rifled to maximize heat transfer. 2. Chilled water coils shall be rated for an operating pressure of not less than 300 psig (2069 kpag). 2.04. Operating Characteristics: A. Unit shall be capable of providing cfm (L/s) airflow at an external static pressure of in. wg (kpag). 2.05. Motor: A. Fan motor of the size and electrical characteristics specified on the equipment schedule shall be factory supplied and installed. B. Motors rated at 1.3 through 3.7 hp (0.97 through 2.76 kw) shall have internal thermal overload protection. Motors rated at 5 hp (3.73 kw) shall be protected by a circuit breaker. C. Evaporator-fan motor shall have permanently lubricated, sealed bearings and inherent automatic-reset thermal overload protection or manual reset calibrated circuit breakers. Evaporator motors are designed specifically for Carrier and do not have conventional horsepower (hp) ratings listed on the motor nameplate. Motors are designed and qualified in the airover location downstream of the cooling coil and carry a maximum continuous bhp rating that is the maximum application bhp rating for the motor; no safety factors above that rating may be applied. D. All evaporator-fan motors 5 hp and larger shall meet the minimum efficiency requirements as established by the Energy Policy Act of 1992 (EPACT), effective October 24, 1997. 2.06. Special Features: A. Staged Air Volume System (SAV) for 2-stage cooling models only: Commercial Split Systems Builder 1.36 Page 19 of 22

Guide Specification for FCU-72 1. Evaporator fan motor: a. Shall have permanently lubricated bearings. b. Shall have a maximum continuous bhp rating for continuous duty operation; no safety factors above that rating. c. Shall be Variable Frequency duty and 2-speed control. d. Shall contain motor shaft grounding ring to prevent electrical bearing fluting damage by safely diverting harmful shaft voltages and bearing currents to ground. B. Variable Frequency Drive (VFD). Only available on 2-speed indoor fan motor option (SAV): 1. Shall be installed inside the unit cabinet, mounted, wired and tested. 2. Shall contain Electromagnetic Interference (EMI) frequency protection. 3. Insulated Gate Bi-Polar Transistors (IGBT) used to produce the output pulse width modulated (PWM) waveform, allowing for quiet motor operation. 4. Self-diagnostics with fault and power code LED indicator. Field accessory Display Kit available for further diagnostics and special setup applications. 5. RS485 capability standard. 6. Electronic thermal overload protection. 7. 5% swinging chokes for harmonic reduction and improved power factor. 8. All printed circuit boards shall be conformal coated. C. Alternate Motor and Drive: 1. An alternate motor and/or medium-static or high-static drive shall be available to meet the airflow and external static pressure requirements specified on the equipment schedule. D. Unit Subbase: 1. Subbase assembly shall be factory-supplied for field installation. Subbase shall elevate floor-mounted vertical units to provide access for correct condensate drain connection. E. Economizer: 1. Economizer for ventilation or free cooling shall be factory provided for field installation on either return air opening of air handler. For free cooling applications, economizer shall be compatible with separate thermostat; economizer dampers shall open when outdoor air enthalpy is suitable for free cooling. Economizer shall be compatible with separate CO2 sensor accessory; economizer dampers shall open when indoor CO2 level rises above predetermined set point. Economizer shall include enthalpy control and damper actuator. F. Thermostat Controls: 1. TEMP System programmable communicating multi-stage thermostat with fan switch, time clock, LCD display, F/ C capability, and CCN (Carrier Comfort Network ) compatibility. 2. Commercial Electronic Thermostat with 7-day time clock, auto-changeover, multi-stage capability, and large LCD temperature display. G. CO2 Sensor: 1. Sensor shall provide the ability to signal the economizer to open when the space CO2 level exceeds the predetermined setpoint. Sensor shall have the capability of being connected to Comfort System relay pack or to economizer using field-supplied and field-installed Honeywell dc adapter no. Q769C1004. H. Display Kit for Variable Frequency Drive 1. Kit allows the ability to access the VFD controller programs to provide special setup capabilities and diagnostics. 2. Kit contains display module, mounting bracket and communication cable. 3. Display Kit can be permanently installed in the unit or used on any SAV system VFD controller as needed. Commercial Split Systems Builder 1.36 Page 20 of 22

Unit Feature Sheet 38AP GEMINISELECT AIR COOLED CONDENSING UNITS These condensing units feature two independent refrigerant circuits, each circuit having its own highly efficient scroll compressors. All units are factory wired, nitrogen charged, and easily connected by refrigerant lines and control wiring to the matching Carrier air-handling unit (40RU or 39 Series). Various combinations of these extremely flexible condensing units matched with air handlers provide customized packages to cover a wide range of cooling requirements. Low roof-load weight distribution and weatherproof construction make these units excellent selections for rooftop or on-the-ground installations. These 38AP condensing units are well suited for commercial or industrial air conditioning applications. These dependable split systems match Carrier's 40RU or 39 Series indoor-air handlers with the versatile outdoor 38AP condensing units for a wide selection of commercial cooling solutions. Split condensing units compatible with ASHRAE 90.1 Chlorine-free, non-ozone depleting Puron refrigerant (R-410A) Condenser coils feature the Novation heat exchanger with microchannel coil technology 38APS single-circuit unit has up to 3 rotary scroll compressors 38APD unit has up to 6 rotary scroll compressors with 2 independent circuits Standard scroll compressor units operate as low as 33% (single circuit) or 15% (dual circuit) of nominal capacity Optional digital scroll compressors allow incremental unloading down to 10% (single circuit) or 5% (dual circuit) of nominal capacity for VAV applications Protection against high discharge and low suction refrigerant pressure, and low oil pressure Commercial Split Systems Builder 1.36 Page 21 of 22

COMMERCIAL SPLIT SYSTEMS 40RUA DIRECT EXPANSION PACKAGED AIR-HANDLING UNITS with PURON REFRIGERANT 40RUA 6 TO 30 TON CHASSIS SHOWN 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. STANDARD FEATURES FOR PURON (R-410A) HFC Refrigerant Cleanable insulation treated with an anti-microbial agent. Two sloped condensate pans on each unit for horizontal or vertical applications. 2 inch filters. Powerful belt-driven forward curved fans. Factory-installed fan motor and contactor. Refrigerant metering devices (TXV's) -- factory installed. Easy maintenance -- removal of a single panel allows access to virtually all components. Single blower on 07 to 12 sizes; dual blower on 14 to 30 sizes. 24-volt terminal block for control wiring connection. Standard one year warranty. 40RUA DIRECT EXPANSION PACKAGED AIR-HANDLING UNITS The 40RUA units are completely packaged direct expansion air-handling units offering the ultimate in installation ease and flexibility. Combined with Carrier 38AU Series condensing units these packaged air handling units offer system capacities from 6 up to 30 tons. These units may be installed in either the vertical or horizontal configuration with no modifications. Powerful fan systems allow easy adaptation to existing ductwork. Heating capability is provided by electric heaters, hot water coils or steam coils. Certified to ISO 9001:2000 Commercial Split Systems Builder 1.36 Page 22 of 22