NOVALYNX CORPORATION MODEL A & A SLING PSYCHROMETER INSTRUCTION MANUAL

Similar documents
NOVALYNX CORPORATION MODEL A EVAPORATION PAN AUTOMATIC REFILL SYSTEM INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

NOVALYNX CORPORATION

Model 5190-F Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe

Ambient Weather WS-DP02 Digital Psychrometer with Temperature, Humidity, Heat Index, Dew Point, Wet Bulb Temperature and Clock User Manual

NovaStar 4X Pager Alarm Software 5073NS4X-AD DCN-M409

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc.

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

Sound Cover [ , , , ]

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Ledco XL-44 Wide Format Pouch Laminator

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Aspirations-Psychrometer Assmann Model / 000


Humidity An excuse for the 80s

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Instruction Manual. Double Candy Apple Cooker

Installation and Operations Manual

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Model 6021 Electrically Heated Rain and Snow Gauge

Chapter 5: Atmospheric Moisture

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Notes: 1 Square = 1 Foot

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

HI COD REACTOR and Test Tube Heater 2008 Series

Part No Revised: October 2004 BUN WARMER. Instruction Manual. Models:8018,8019,8117,8219,8170

V LPM Desiccant Air Dryer Installation and Operation Manual

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Digital Refrigerator/Freezer Thermometer model 00986

Instruction Manual. Carmel Apple-Dip Warmer

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

Condiment Warmer. Instruction Manual Models #2252EX & #2253EX. Cincinnati, OH USA. Model #2252EX. Model #2253EX

EQUIPMENT Operation Manual

RK/ RK Oxygen Detector Operator s Manual

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Large Combo Warmer Instruction Manual Model #2206

User's Guide. Pinless Moisture Meter. Model MO257

InstructIon Manual KrEs EQuIPMEnt stands

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS

Cat 5 Pro Vacuum OPERATOR S MANUAL

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Models: SV1 (110V) SV1EU ( V) User s Manual. Register your product and get support at. v

WA A Aqua Sub Bottom-load Water Cooler

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

Cheese Display Case. Instruction Manual Model #5580BV2 and Model #5580BV3 Model #5582 and Model #5583. Cincinnati, OH USA.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Field Top Mounted Condensing Unit

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Portion Bag Cheese Warmer

Air Pump Up to 800 gallons

Reacti-Therm I and III Heating Modules

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Humidity Monitor model 01080

Karbon Kitchen Sink Tap

RCM-C Vinyl Cleaner. Part List: Operation conditions:

5300, 5300CH, 5300EX, 5300FN

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

PSYCHROMETERS. for Determination of True Temperature and Humidity of the Air 131,0E DR. ALFRED MÜLLER METEOROLOGISCHE INSTRUMENTE KG R.

Reacti-Therm I and III Heating/Stirring Modules

COOPER POWER SERIES. CT Protector Retrofit Kit. Voltage Regulators MN225057EN. Effective March 2017 Supersedes March 2010 (S )

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

IFS Fiber Module Installation & Operation Instructions

Part No Revised December 2002 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5510, 5511 AND 5512

MODEL HBX-1 P/N 3G59332

HIn3550 Magnetic Field Monitor User's Manual

Please read and follow all instructions for usage and maintenance before operating the VACMASTER SV1 Immersion Circulator.

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

High Temperature InfraRed Thermometer with Laser Pointer

Part No Revised November 2004 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5513

Compressed Air Dryer

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Thermometer model 02059

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Instruction Manual Hydraulic Crimping Tool

Digital Heat Block User Manual

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Dual Laser InfraRed (IR) Thermometer

Instruction Manual. Nacho Cheese Dispenser and Warmer

Duct Mount. Installation Instructions

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

AMC-CD2. Human Occupancy Detector INSTRUCTION MANUAL. Please read these instructions completely and carefully before starting.

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Corrosion Resistant Fluid and Air Handling Systems.

RPI Industries, Inc.

HVAC (Heating, Ventilating, and Air Conditioning)

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

USE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100

Note To The User: This product has updated features not yet mentioned in the product manual.

Thermometer with Probe model 00891A

Transcription:

NOVALYNX CORPORATION MODEL 225-570-A & 225-571-A SLING PSYCHROMETER INSTRUCTION MANUAL REVISION DATE: 08/2007

Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify NovaLynx Corporation immediately concerning any discrepancy. Inspect equipment to detect any damage that may have occurred during shipment. In the event of damage, any claim for loss must be filed immediately with the carrier by the consignee. Damages to equipment sent via Parcel Post or UPS require the consignee to contact NovaLynx Corporation for instructions. Returns If equipment is to be returned to the factory for any reason, call NovaLynx between 8:00 a.m. and 4:00 p.m. Pacific Time to request a Return Authorization Number (RA#). Include with the returned equipment a description of the problem and the name, address, and daytime phone number of the sender. Carefully pack the equipment to prevent damage or additional damage during the return shipment. Call NovaLynx for packing instructions in the case of delicate or sensitive items. If packing facilities are not available take the equipment to the nearest Post Office, UPS, or other freight service and obtain assistance with the packaging. Please write the RA# on the outside of the box. Warranty NovaLynx Corporation warrants that its products are free from defects in material and workmanship under normal use and service for a period of one year from the date of shipment from the factory. NovaLynx Corporation's obligations under this warranty are limited to, at NovaLynx's option: (i) replacing; or (ii) repairing; any product determined to be defective. In no case shall NovaLynx Corporation's liability exceed product's original purchase price. This warranty does not apply to any equipment that has been repaired or altered, except by NovaLynx Corporation, or that has been subjected to misuse, negligence, or accident. It is expressly agreed that this warranty will be in lieu of all warranties of fitness and in lieu of the warranty of merchantability. Address NovaLynx Corporation 4055 Grass Valley Highway, Suite 102 Auburn, CA 95602 Phone: (530) 823-7185 Fax: (530) 823-8997 Email: nova@novalynx.com Website: www.novalynx.com Copyright 1988-2012 by NovaLynx Corporation i

TABLE OF CONTENTS Section No. Page No. 1.0 INTRODUCTION.................................................. 1 2.0 SPECIFICATIONS................................................. 1 3.0 THEORY OF OPERATION........................................... 1 4.0 USING THE PSYCHROMETER....................................... 2 5.0 MAINTENANCE................................................... 2 ii

iii

NovaLynx Corporation Model 225-570-A & 225-571-A Sling Psychrometer Instruction Manual 1.0 INTRODUCTION The Model 225-570-A and 225-571-A Sling Psychrometers are used to measure dew point temperature and relative humidity. A sling psychrometer employs two thermometers, one wet bulb and one dry bulb, to observe the temperature of evaporation; that is, the difference between the temperatures indicated by wet bulb and dry bulb thermometers. Model 225-570-A has thermometers graduated in degrees Fahrenheit while Model 225-571-A has thermometers graduated in degrees Celsius. 2.0 SPECIFICATIONS Temperature range: 225-570-A 225-571-A Size: Weight/Shipping: -20 to +120 F -30 to +50 C 12" L x 1.5" W (305 mm x 38 mm) 0.4 lb/1 lb 3.0 THEORY OF OPERATION A psychrometer is an instrument designed to measure dew point temperature and atmospheric relative humidity through the use of a wet bulb thermometer and a dry bulb thermometer. Typically, both thermometers are physically identical. The instrument consists of a pair of thermometers mounted on a metal frame, with a handle which permits the thermometers to be whirled rapidly; the bulbs being thereby strongly affected by the temperature and moisture in the air. The lower of the two bulbs is covered with a cotton wick, which should be wet at the time an observation is made. Two readings are obtained; a dry air temperature reading and a wet bulb temperature reading. The difference between the wet bulb and the dry bulb reading is called the "depression". By knowing the dry bulb temperature and the depression temperature, dew point temperature and relative humidity can be obtained from psychrometric tables. 1

4.0 USING THE PSYCHROMETER To use the psychrometer, the following steps are recommended: 1. Check the wet bulb thermometer to ensure that the cotton wick has been securely tied onto the bulb. Use a cotton thread to tie the wick to the bulb. Do not touch the wick with your fingers or skin. Oils in human skin will affect the operation of the cotton wick. Use a tweezers or rubber gloves to handle the wick. 2. Saturate the muslin on the wet bulb by dipping it into a small cup or wide-mouthed bottle of water. Distilled water is recommended. The entire wick should be saturated. 3. Whirl the psychrometer rapidly for 15 or 20 seconds. Stop and take readings quickly, noting the wet bulb reading first. Immediately whirl the unit again and take a second reading. Repeat this process three or four times until at least two successive readings of the wet bulb are found to agree very closely, thereby showing that it has reached its lowest temperature. 4. Calculate the temperature depression and use that value and the dry bulb reading to obtain the dew point or humidity value from the psychrometric chart. 5.0 MAINTENANCE Cleanliness is important to the correct operation of any psychrometer. The wick should remain clean at all times. Residue on the wick will result in errors in the temperature readings. Replace the wick before each reading for best results, especially when there is an extended time between readings (days, weeks, or months) or when there are high concentrations of atmospheric contaminants present at the testing location. Periodically check both red liquid thermometers to ensure that they read the same (within the specified accuracy of the thermometers) when both are used as dry bulb thermometers. Replacement Parts: 225-572-A Thermometer, -20/120 F 225-573-A Thermometer, -30/50C 225-568 Wick Material, 24" length 2