DEVIATING VALVES ART K063

Similar documents
THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Mercury Mixing Kit (Code: ME1053)

Thermostatic mixing valves with replaceable cartridge for centralized systems

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

Thermostatic mixing valves with interchangeable cartridges

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Metering systems 0548EN April 2014

Light oil / kerosene burner

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Roth fixed-value control set with high-efficiency pump

Components for solar heating systems

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

R557R EN January 2012

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

caleffi hydronic valves page 1 of 12

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

Forced draught gas burner

WARNINGS FOR THE USER: Connect BASE conforms to: Low Voltage Directive 73/23/EEC. Electromagnetic Compatibility Directive 89/336/EEC

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

Solar station DKP 6-8 / DKP Installation and Service Manual C

Installation, commissioning and servicing instructions

FOR INSTALLING AND USING

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Convertible radiator valve for one-pipe systems, centre distance 35 mm

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

V. DIFFERENTIAL THERMOSTAT

S170 - SOLAR STORAGE-TO-BOILER CONNECTION KIT WITH THERMAL INTEGRATION

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Light oil - kerosene burner

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Mounting and Operating Instructions EB 2231 EN

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Flush individual room control for floor heating systems

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

Systems for central heating

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

Section - A. Radiator Valves

SECTION 3. OPERATING INSTRUCTIONS

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

MODEL CMA-130VL PARTS MANUAL Rev 1.00

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

SUN EQUINOX HEATING SYSTEMS

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

Owner s Manual Crimping Machine CM 25-6

Installation and instruction manual SOLAR STATION

geothermal march 2011

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

ROTEX RMX Heating circuit distributor

SMART Electronic control for towel radiators

Forced draught gas burner

TECHNICAL INFORMATION Touchtronic Clothes Dryers

General System Layout Sketch

HEAT RECOVERY AIR HANDLING UNIT

product overview ProControl

Model: 1100 Float-Controlled Condensate Trap, PN 25

TS RD 7761 RD, 7761 RD

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

DRAIN WATER TEMPERING INSTALL

2.A MANIFOLD SHUNTS MINI SHUNTS

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

DOMESTIC STEAM GENERATOR Installation Instructions

VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com

Operating & Safety Instructions

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

HERZ Differential Pressure Control Valve 4002

IH 025 VOLCANO. Portable Induction Heater. smart mounting

TDS 20 R / TDS 30 R / TDS 50 R

FHM-Cx Mixing Shunts for Floor Heating

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

Control valves for floor heating systems. Floor Heating Manifolds

RA2000 Thermostatic Radiator Valves

Light oil burners. One stage operation

Transcription:

FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art. 992, 995. The three-way mixing valve with thermostatic sensor with remote capillary Art. 323, allows to mix two fluids obtaining a third one with intermediate temperature. Adjustment range 20-50 C. The probe also works on contact. For immersion, combine sensor holder well Art. 212 or 189. Art. 307 The adjustment and mixing group Art. K063 has been designed for use in radiant panel systems, in combination with distribution manifolds. Its function is to maintain constant, at the set value, the flow temperature of the fluid distributed in a low temperature radiant panel system. The thermal regulation takes place by means of a three-way thermostatic valve, equipped with a thermostatic control with remote sensor. TECHNICAL FEATURES TECHNICAL DATA: Fluid of use: Water and glycol solutions Maximum percentage of glycol: 30% Primary input temperature range: 5 95 C Adjustment temperature range: 20 50 C Scale thermometers: 0 60 C Maximum working pressure: 10 bar Minimum operating pressure: 1 bar Power supply: 230 V - 50 Hz MATERIALS: Valve and fitting bodies: Brass CW617N - UNI EN 12165 Ferrule and nipples: Brass CW617N - UNI EN 12165 Thermometer: Steel/Alloy Gaskets: EPDM Perox CONNECTIONS: Secondary system connections (manifolds): G1 M Art. 323 Art. K063 pag. 1

MIXING VALVE ADJUSTMENT The thermostatic control with remote sensor that is to be installed on the 3-way mixing valve is supplied with the "fixed point regulating unit". By adjusting the thermostatic control it is possible to set the temperature of the heat transfer fluid that circulates within the low temperature circuit of the radiant panels. The thermostatic control has an adjustment range that goes from 20 to 50 C, it is advisable to set a temperature of about 35/40 C on the handwheel with the graduated scale (for a detailed description of the thermostatic control regulation refer to the sheet instructions in its package). The three-way mixing valve, on the other hand, is equipped with a "double regulation" which allows limiting the amount of water that is to be allowed to enter the low-temperature circuit in the condition in which the mixing valve is completely open. This "double adjustment" is set at the factory when the mixing valve is tested, it is advisable not to modify it except for special requirements. To change the "double adjustment" it is necessary to remove the white cap or the thermostatic control on the mixing valve (the valve will appear as in fig.a), insert a slotted screwdriver into the slot on the black pin (see the red arrow in fig.b), turn the pin by varying the mixing valve regulation as follows: Fig. A - Turning the black pin clockwise closes the passage of the heat transfer fluid to the low temperature system, limiting its passage to a maximum value even if the mixing valve is in the fully open position. - Turning the black pin anti-clockwise instead opens the passage of the heat transfer fluid to the low temperature system, increasing the maximum amount of water that is allowed to pass in the low temperature circuit in case the mixing valve is in position of complete opening. Fig. B pag. 2

MIXING VALVE FLOW DIRECTION CLOSED VALVE OPEN VALVE 130 FLOW DIRECTION SYSTEM SUPPLY BOILER SUPPLY SYSTEM RETURN BOILER RETURN pag. 3

ART. K063 - ADJUSTMENT GROUP WITH FIXED POINT Fixed point temperature regulation group complete with: 1) Thermostatic control 20-50 C with remote sensor 2) 3-way mixing valve 3) Flow meter 4) By-pass valve with manual regulation 5) Sensor holder well 6) G1 "nozzles with O-ring seal for the manifold Connections for manifolds: G1 "Male. Installable both in the right version and in the left version. 1 6 6 5 2 6 3 6 4 BY-PASS VALVE ADJUSTMENT The manually controlled by-pass valve allows to regulate the circulation of the heatcarrying fluid coming from the heat generator in the event that the mixing valve is completely closed and does not allow anything to pass towards the collector of the low-temperature circuit of the radiant panels. To obtain a standard regulation of the by-pass valve, it is advisable to close it completely by rotating the white handwheel (indicated by the blue arrow in fig. C) clockwise until it stops and then open it by 1 / 1.5 turns by turning the handwheel counterclockwise. Fig. C pag. 4

HYDRAULICAL FEATURES pag. 5

DIMENSIONS SERIE CODE A B C D E 307 82307AD05 1/2" 59 118 60,5 45 307 82307AE05 3/4" 59 118 60,5 45 307 82307AF05 1 64 128 70,5 45 SERIE CODE A B C D E 323 82323AD05 1/2" 59 118 60,5 104,5 323 82323AE05 3/4" 59 118 60,5 104,5 323 82323AF05 1 64 128 70,5 104,5 pag. 6

SERIE CODE A B C D E F K063 87K063PG06 1" 55 210 368 103 131 pag. 7

SAFETY Read the installation and commissioning instructions carefully before operating the appliance in order to prevent accidents and system failures caused by improper use of the product. Please note that the right to the warranty is void in case of unauthorized modifications or tampering during the assembly and construction phase. In addition to the aforementioned directives, the following rules must necessarily be followed: DIN 4751 Water heating systems DIN 4757 Solar heating systems DIN 18380 Domestic water heating and heating systems DIN 18382 Electrical and conduction systems in buildings DIN 12975 Solar thermal systems and their construction WORKING CONDITION The limit values shown must in no way be exceeded. Operational safety is therefore ensured by respecting the general conditions and operating limit values described in this sheet. SAFETY RULES FOR MOUNTING AND INSPECTION Assembly and inspection must be performed by qualified, authorized personnel who are familiar with the instructions given here. Before any work on the equipment is necessary to make sure that they are in rest conditions. ELECTRICAL CONNECTIONS The electrical connections must be made by qualified personnel. Before powering up the relay unit, check that the data indicated on the nameplate regarding the type and voltage values supplied by the electricity grid are respected. All connections must be made as prescribed by law. MAINTENANCE Maintenance operations must be performed by qualified, authorized personnel who are familiar with the instructions given here. Before any work on the equipment is necessary to make sure that they are in rest conditions. If the pump is to be replaced, the shut-off valves should be turned to the closed position. Warning! Depending on the operating conditions of the pump and the characteristics of the system, the surface temperature may be very high. Therefore, if you touch the pump directly, you are in danger of burns! DECLARATION OF CONFORMITY (CE) The circulators supplied as part of the ICMA relay groups comply with the following harmonization directives: EEC Machinery Directives 89/392 / EEC, 91/368 / EEC, 93/44 / EEC, 93/68 / EEC. Electromagnetic compatibility 89/336 / EEC, 92/31 / EEC, 93/68 / EEC General harmonized rules EN 809, EN 50081-1, EN 50081-2, EN 50082-1, EN 50082-2. pag. 8