Blow through unit coolers LEX. Standard coolers for cooling & freezing rooms

Similar documents
The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

Air cooler BC50 Blast freezer

Alfa Laval Arctigo ID

Air cooler VNS Agricultural

Goedhart VNS. Air coolers for agricultural applications Cu/Al R404A - CO 2. engineering for a better world. GEA Heat Exchangers

HEATING & COOLING COIL PRODUCTS

Compact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.

Fincoil FMP and FMPG. Air coolers and liquid circulated air coolers

Engineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle

TEC Coolers. GEA Heat Exchangers. GEA Searle

Spare parts. Alfa Laval Arctigo IS - Industrial air coolers

Küba SG commercial

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

Condensing Units CUS 15-60

Evaporators 60HZ version

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

Brazed heat exchangers

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

WORKING IN A DRAFT-FREE ENVIRONMENT

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

LOW PROFILE EVAPORATORS

Compact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw

Antarctic-Unit Cooler/Air Cooler

VERSO Air Handling Units

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

TOPAZ ADIABATIC COOLER

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

New Industrial Dual Flow Unit Coolers

Remote Air Cooled Condensers C2 Series

VERSO Air Handling Units

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC

Liquid desiccant dehumidification systems. Product guide

AlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Alfa Laval Arctigo IS

Main technical datas:

Kirby CO 2 Evaporators

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Compact VERTICAL FLAT. Compact. Condensers GCHC/GCVC for HFCs, NH 3

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

Air-Cooling Evaporators

Industrial Unit Coolers

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

GEA Searle Cooler and Condensing Unit Ranges Top-level engineering solutions. engineering for a better world. GEA Heat Exchangers

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

AIR COOLERS FOR WIDE RANGE OF APPLICATIONS

Technical Data Ducted Three Phase Split System Air Conditioner

QZHW Fan Coil Unit. Key features. Specifications

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

High Profile Evaporator

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

AIR COOLERS FOR WIDE RANGE OF APPLICATIONS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Low Profile Unit Coolers

PGDX Rectangular duct coolers with DX coil

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Alfa Laval Optigo CC. Instruction manual. Product description Product labels Unpacking & lifting Installation Maintenance Spare parts

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

AQUASNAP JUNIOR 30RHV

recooler HP EQKR HEAT PUMP

500 EX Fusion Compressor Series

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers


HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

30GN FLOTRONIC II AIR-COOLED CHILLERS

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

MAC-120HE-03 Air-Cooled Chiller

Cassette units Model Comfort Circle. - heating - cooling - ventilation

PACKAGED REFRIGERATION CONDENSING UNITS

Roof top SPACE RPC 450Z R407C M011

MACH N-407 Heat Pump Air-Cooled Chiller

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Transcription:

Blow through unit coolers LEX Standard coolers for cooling & freezing rooms

O `çåíéåíë pag. Model indication..................................2 Eurovent.......................................2 General information...............................3 Options & non-standard configuration.................4 Fan data & defrost systems.........................5 Correction factors & selection examples...............6 Capacities & technical data.........................7 bìêçîéåí= Within Europe, a wide variety of published data on capacities are in use, generally depending on national standards. Most in use by the leading manufacturers are national and international standards like DIN, ENV, NEN- EN and ASHRAE. Due to this, customers have not been able to make objective product comparisons, since data published on capacities were based on DT 1, DTM, dry or wet conditions, with or without certification, etc. To meet the European requirements on EN standards, the European Refrigeration Industry embodied by Eurovent has set standards to guarantee an independent certification procedure for forced convection air cooled condensers based on NEN-EN 327 and unit air coolers based on NEN-EN 328. Being an active member of Eurovent, the capacities of the Helpman commercial cooler programme, as given in the technical documentation, are based on NEN-EN 328 (evaporating temperature t o = - 8 C, 8 K temperature difference between airon temperature and evaporating temperature (DT 1 )). jççéä=áåçáå~íáçå In order to enable air cooler selection for operating conditions, technical documentation should also give capacities for humid/frosted conditions. According to Eurovent these frosted conditions are to be calculated by multiplying dry capacities with a factor 1.15. These data can be found in the capacity tables, in the columns marked frosted. `~é~åáíáéë Pos. Reference Options 1 Cooler type 2-30 2 Current 3 Options 400 = 230/400/50/3 230 = 230/50/1 For a full survey of all available options see page 4. Frosted conditions Lightly frosted coil. Relative humidity 85 %. Suction gas superheating 62% of the temperature difference (DT 1 ), with a minimum of 3.5 K. Refrigerant liquid temperature 30 C (for t 0 = - 20 C and below: liquid temperature 10 C). Evaporating temperature t 0 Evaporating temperature t 0 is the saturated temperature according to the pressure at the suction outlet of the cooler. Dry conditions Cooling capacity where no condensation or ice build-up occurs on the coil (100% sensible cooling). This condition is used by Eurovent to standardise capacity ratings but should not be used when selecting coolers. For cooler selection use the columns marked frosted.

P déåéê~ä=áåñçêã~íáçå LEX coolers are blow through unit coolers for application in cooling and freezing rooms for the temperature area +5 C up to -40 C. The air coolers are suitable for all halocarbon refrigerants. Capacity range (Eurovent SC2) 1.3 to 40.1 kw. Air flow 1080 up to 26000 m 3 /h. mba All coolers and condensers produced by Helpman comply with the Pressure Equipment Directive 97/23/EC. In this respect all equipment is provided with extensive product information. PED certificates may be downloaded from www.helpman.com (standard products only). Two-Year Guarantee= Because Helpman has the fullest confidence in the product quality, a two-year full guarantee is given. líüéê=~áê=åççäéê=ãççéäë Based upon the same coil configuration as the LEX range Helpman supplies the following air cooler models: PX Low silhouette unit coolers (brochure 50.03) PLV Mini air coolers (brochure 50.04) LDX Dual discharge air coolers (brochure 55.07) LFX Agricultural storage coolers (brochure 55.15) mêççìåíåçåñáöìê~íáçå= Coil Copper Ripple Fin tubing ø 2 Tube centres 38 x 38 mm square pitch Aluminium fins Fin spacing 7 mm. Coils are pressure tested with dry air at 36 bar. 1-4 Fans, blowing through the coil, diameters 254 up to 508 mm. Fan motors protection class IP55. Eflo refrigerant circuiting for higher effective cooling capacity. Durable aluminium casing, white epoxy coated (RAL 9003). Models up to LEX 12 fitted with hinged interchangeable side plates. Bigger models fitted with easy removable side plates. All models equipped with splash guard. Optimized refrigerant circuiting. Refrigerant connections on right hand side (fan side view). Equipped with a schräder valve on the suction connection for testing purposes. Sufficient room for fitting the expansion valve inside. Standard suitable for dry expansion (DX system). All models available on request for pumped circulation and glycol. Stickers indicate fan direction and refrigerant in/out. Heavy duty packing in wooden crates. LEX 18 and up delivered on wooden beams in mounting position. Installation can take place using a forklift.

Q léíáçåë= Defrost systems Electric defrost E2 Fan ring heater Fan ring heater (230 Volt) Incl. mounting gear LEX type Fan diameter mm FRH Ring heater power Watt 14, 20 406 400 16, 22, 26 457 450 24, 28, 30 508 500 bñäç=êéñêáöéê~åí=åáêåìáíáåö The optimal use of the available heat exchanging surface by means of EFLO liquid distrtions system is based on two principles: The refrigerant is evaporating throught the coil in parallel flow with the air. Superheating takes place on the air-inlet side, in the area with the highest tube temperature. With Eflo, the cooling performance improves as a result of: Even frost formation over the coil. Prolongued cooling cycle, therefore a higher effective cooling capacity. Shorter defrost cycle. Isolating switch (mounted) ISM Non-standard executions==eçå=êéèìéëí=çåäóf= Special fan motors: Single phase/three phase motors Traploos regelbare motoren 60 Hz models on request Increased external pressure Defrost systems Hot gas coil in driptray G1 complete counterflow 1) Refrigerant inlet temperature 2) Beginning of superheating refrigerant vapour 3) Evaporating temperature (t 0 ) corresponding with the pressure at the outlet of the cooler 4) Superheating temperature 5) Air-inlet temperature 6) Air-outlet temperature

R aéñêçëí=póëíéãë Two forced defrost designs are available for LEX coolers : hot gas defrost and electric defrost. Each defrost system is optimised for specific applications and ambient conditions. bäéåíêáå=çéñêçëí=bo= Stainless steel heater elements placed in additional tubes between the evaporator tubes. The elements for the driptray are fitted to the bottom of the inner tray. Both coil and driptray have the same elements. Standard voltage per element 230 V. Connection to 230 V / 1 phase or 400 V / 3 phase, connected in star with Zero-Wire. Total defrost power is given for 400 V / 3 phase with Zero-Wire. All elements can be withdrawn at the refrigerant connection side. The driptray elements can be taken out after removal of the outer tray. The heater elements are pre-wired and are connected to one or more terminal boxes. The following electric defrost system is available for LEX coolers: E2 aéñêçëí=éçïéê Air on temperature down to - 25 C. Electric stainless steel defrost elements in coil block and driptray. Electrical defrost E2 Cooler- number of elements defrost power kw model coil block driptray standard reduced LEX 2 1 1 1.28 LEX 4 2 1 2.64 LEX 6 2 1 2.64 LEX 8 2 1 3.00 LEX 10 2 1 4.80 LEX 12 2 1 4.80 LEX 14 5 1 4.90 3.7 LEX 16 5 1 5.62 4.2 LEX 18 5 1 8.34 6.3 LEX 20 5 1 8.40 6.3 LEX 22 5 1 11.1 8.3 LEX 24 5 1 11.1 8.3 LEX 26 5 1 19.2 14.4 LEX 28 5 1 19.2 14.4 LEX 30 5 1 22.2 16.7 eçí=d~ë=aéñêçëí=dn=eçå=êéèìéëí=çåäóf= The driptray can be fitted with a copper defrost coil to bring it rapidly up to temperature bu means of hot gas. This system may be applied to air on temperatures down to -5 C. c~åë Fans are executed with balanced aluminium or polyamide fan blades, fitted with robust electrolytically galvanized and epoxy coated fan guards according to DIN 31001. Fans are mounted in vibration dampers. Enclosed design spray-tight motors, protection class IP-55. Motor windings suitable for 230 Volt. All motors are equipped with a thermal safety device built in the windings, connected to separate terminals in the box. This safety device can therefore be integrated into the control circuit. The electrical control should be arranged preferably with a manual reset device in order to prevent continuous on/ off switching (tripping) of the motors. Thermal safety device values (A) Fan motor Temperature C +10 0-20 -40 230 / 50 / 1 30 W 0.5 0.5 0.6 0.6 70 W 1.2 1.2 1.3 1.4 220 W 2.5 2.6 2.8 2.9 370 W 3.5 3.7 4.0-230 / 400 / 50 / 3 30 W 0.3 0.3 0.3 0.3 90 W 0.5 0.5 0.6 0.6 250 W 1.1 1.1 1.1 1.2 370 W 1.4 1.4 1.4 1.5 ^áê=íüêçï= The throws as given in the tables are for veilng mounted coolers at t = 20 C, an unrestrained air flow in the cold room and a minimal air velocity of 0.25 m/s at air throw distance. pçìåç=éêéëëìêé=ç_e^f Sound pressure as given in the tables are sound pressure levels in db(a) at 5 m distance in free field conditions. Values may deviate depending on situations at site. The table below gives calculated sound pressure corrections at various distances. Distance m Correction db(a) 1 + 14 2 + 8 3 + 4 4 + 2 5 0 10-6 20-12 50-20

S péäéåíáçå=bñ~ãéäé=aq N Refrigerant..............................R-404A dx Required cooling capacity.................... 6.8 kw Air-on temperature.......................... -16 C Evaporating temperature..................... -25 C 1) DT 1 = -16 - ( -25 ) = 9 K 2) Correction factor DT 1 /R-404A : 1.06 3) Multiply required capacity with correction factor: 6.8 x 1.06 = 7.2 kw. 4) Cooler models can be selected in columns capacity / frosted on page 7 with a nominal capacity of 7.2 kw. For the above mentioned conditions the following models can be selected: LEX 14, nom. cap. 5.9 kw. LEX 16, nom. cap. 7.9 kw. Depending on parameters such as air flow, number of fans and dimensions (see tables) a final cooler model selection can take place. Capacity values under dry conditions are reference values for Eurovent conditions. Standardcondition SC Air on temp. C Evaporating temperature C SC 2 : Nominal capacity for cooling design. Factor dry/ frosted SC1 10 0 1.35 SC2 0-8 1.15 SC3-18 -25 1.05 SC4-25 -31 1.00 Air-on temperature is the air temperature at the intake side of the coil block. `çêêéåíáçå=ñ~åíçêë= DT 1 Evaporating temperature C K +5 0-5 -8-10 -15-20 -25-30 -35 R-404A & R-507 dx 6 1.28 1.32 1.38 1.44 1.51 1.58 1.64 1.69 1.72 7 1.06 1.10 1.15 1.20 1.27 1.33 1.39 1.44 1.48 8 0.89 0.93 0.97 1.00 1.03 1.09 1.15 1.21 1.26 1.29 9 0.77 0.80 0.84 0.89 0.95 1.00 1.06 1.11 1.15 10 0.67 0.70 0.74 0.78 0.83 0.89 0.95 1.00 1.04 11 0.59 0.62 0.65 0.70 0.74 0.80 0.85 0.90 0.94 R-134a dx 6 1.34 1.42 1.50 1.60 1.71 1.82 1.94 7 1.11 1.17 1.25 1.34 1.43 1.54 1.64 8 0.94 0.99 1.06 1.14 1.23 1.32 1.42 9 0.81 0.86 0.92 0.99 1.07 1.16 1.25 10 0.70 0.75 0.80 0.87 0.94 1.03 1.11 11 0.62 0.66 0.71 0.77 0.84 0.92 1.00 R-22 dx 6 1.34 1.39 1.45 1.52 1.59 1.66 1.73 1.78 1.81 7 1.11 1.15 1.21 1.27 1.33 1.40 1.47 1.52 1.55 8 0.94 0.98 1.03 1.08 1.14 1.21 1.27 1.32 1.36 9 0.81 0.84 0.89 0.94 1.00 1.06 1.12 1.17 1.21 10 0.70 0.74 0.78 0.82 0.88 0.94 1.00 1.05 1.09 11 0.62 0.65 0.69 0.73 0.78 0.84 0.90 0.95 0.99 R-404A & R-507A pumped system 6 1.00 1.07 1.13 1.19 1.24 1.29 1.34 1.39 1.44 7 0.82 0.88 0.94 1.00 1.05 1.10 1.15 1.20 1.25 8 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.11 9 0.60 0.65 0.69 0.74 0.79 0.84 0.89 0.94 1.00 10 0.52 0.56 0.61 0.65 0.70 0.75 0.80 0.85 0.91 11 0.46 0.50 0.54 0.58 0.62 0.67 0.72 0.78 0.84 R-22 pumped system 6 1.13 1.21 1.28 1.34 1.39 1.44 1.48 1.53 1.58 7 0.92 0.98 1.05 1.10 1.16 1.21 1.25 1.30 1.36 8 0.76 0.82 0.88 0.93 0.98 1.03 1.08 1.14 1.20 9 0.64 0.70 0.75 0.80 0.85 0.90 0.95 1.01 1.07 10 0.55 0.60 0.65 0.70 0.74 0.79 0.84 0.90 0.97 11 0.48 0.52 0.57 0.61 0.66 0.71 0.76 0.82 0.89 Correction factors for other refrigerants on request.

T `~é~åáíáéë=c=íéåüåáå~ä=ç~í~ Capacities R404A / R507A (kw) Fans Cooler model Frosted t 0 =-8 o C Dry t 0 =-8 o C Airflow Coil surface Int. vol. Weight Number Diam. Capacity W nom./absorbed* Air throw Sound pressure Cable inlet DT 1 =8K DT 1 =8K m 3 /h m 2 dm 3 kg mm 230/1 400/3 m db(a) LEX 2 1.3 1.2 1080 4.7 2.1 17 1 254 30/80 30/65 10 48 2 x M20 x 1.5 LEX 4 1.9 1.7 1840 6.7 3.0 21 1 305 70/190 90/190 12 50 2 x M20 x 1.5 LEX 6 2.8 2.4 1750 10.1 4.0 25 1 305 70/190 90/190 12 50 2 x M20 x 1.5 LEX 8 4.4 3.8 2800 15.7 6.0 35 1 356 70/190 90/190 15 53 2 x M20 x 1.5 LEX 10 4.1 3.6 3680 13.5 6.0 32 2 305 70/190 90/190 15 53 2 x M20 x 1.5 LEX 12 5.5 4.8 3500 20.2 6.8 38 2 305 70/190 90/190 15 53 2 x M20 x 1.5 LEX 14 5.9 5.1 3900 21.2 8.0 46 1 406 220/380 250/400 15 57 2 x M20 x 1.5 LEX 16 7.9 6.9 5100 27.9 10.4 61 1 457 220/380 250/400 20 60 2 x M20 x 1.5 LEX 18 9.0 7.8 5600 31.4 11.6 65 2 356 70/190 90/190 20 56 2 x M20 x 1.5 LEX 20 12.2 10.6 7800 42.4 15.5 88 2 406 220/380 250/400 20 60 2 x M20 x 1.5 LEX 22 15.7 13.7 10200 55.9 20.4 111 2 457 220/380 250/400 20 63 2 x M20 x 1.5 LEX 24 20.0 17.4 13000 69.8 28.2 128 2 508 370/500** 370/500 20 66 2 x M20 x 1.5 LEX 26 24.6 21.4 15300 84.2 30.9 159 3 457 220/380 250/400 20 65 2 x M20 x 1.5 LEX 28 31.0 27.0 19500 105.2 39.8 186 3 508 370/500** 370/500 20 68 2 x M20 x 1.5 LEX 30 40.1 34.9 26000 140.1 51.1 256 4 508 370/500** 370/500 20 69 2 x M20 x 1.5 * Fan power is given per motor. Absorbed fan power is measured with coil face area blocked for 75% and ambient temperature of 20 C ** These motors are suitable for temperatures down to -20 C and are NOT provided with a thermal safety device in the windings. aáãéåëáçåë Cooler Dimensions mm Refrig. conn. type A B D F G H K inlet suction* OD ODS LEX 2 598 412 470 365 360 380 ½ ½ LEX 4 658 472 500 395 430 440 ½ ½ LEX 6 658 472 630 503 430 440 ½ e LEX 8 788 602 640 503 505 570 ½ 22 mm LEX 10 1106 920 500 395 430 880 ½ e mm LEX 12 1106 920 630 503 430 880 ½ 22 mm LEX 14 970 692 670 520 60 620 660 ½ 22 mm LEX 16 1110 792 720 520 45 700 760 ½ 22 mm LEX 18 1460 1180 650 500 40 540 1140 ½ 35 mm LEX 20 1640 1360 670 520 60 620 1320 e 35 mm LEX 22 1880 1560 720 520 100 700 1520 e 42 mm LEX 24 1880 1560 820 630 120 850 1520 e 42 mm LEX 26 2650 2328 720 520 100 700 2290 e 54 mm LEX 28 2650 2328 820 630 120 850 2290 e 54 mm LEX 30* 3420 3098 820 630 120 850 3050 e 54 mm * LEX 30: 3 mounting channels, distance2 B (1549 mm) 2 water drains, 1 BSP male, distance 1700 mm Defrost element withdrawal space Defrost element withdrawal space Terminal box for defrost elements Drain ¾ BSP male. Drain(s) 1 BSP male.

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineered solutions. Our equipment, systems and services are dedicated to helping customers to optimize the performance of their processes. Time and time again. We help our customers to heat, cool, separate and transport products such as oil, water, chemicals, beverages, foodstuffs, starch and pharmaceuticals. Our worldwide organization works closely with customers in almost 100 countries to help them stay ahead. How to contact Alfa Laval Up-to-date Alfa Laval contact details for all countries are always available on our website at www.alfalaval.com Helpman products Helpman, a well respected air heat exchanger manufacturer, was acquired by Alfa Laval in 2007. The Helpman brand will remain as a strong product name. Information about Alfa Laval Helpman products is available on the website www.helpman.com. 50.02/05-2007