Moulded Case Circuit breakers

Similar documents
Residual Current Devices

Operation and use. Functions and characteristics

±6kV ±2.5kV (AS unit, close condition) Conventional Free Air Thermal Current (Ith) 250V AC (COSφ=0.95) 0.15A AC

Molded Case Circuit Breakers, Bulletin 140G

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

1.Application. 2.Main Technical Specifications B-10

PLANET -DIN PAGE 12-2 PAGE 12-6 PAGE 12-5

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Moulded case circuit brakers

RD3 and RCQ020 Electronic low-voltage residual current devices for miniature and moulded-case circuit-breakers

Monitoring Relays. 3RN1 Thermistor Motor Protection. For PTC sensors. 7/120 Siemens LV 1 T 2008

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

QA(13) - Series Miniature Circuit Breakers

Product Bulletin. Zenith Controls. Automatic Transfer Switch. ZTG Series. Fully Approved. Design and Construction Features

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Installation, operating and servicing instructions

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Welcome to Hager Presentation

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS

Independent, accredited testing station Member laboratory of STL and LOVAG

Circuit Breaker with Residual Current Protection (CBR)

Refrigerated Air Dryer

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

SENTRY. MCB Isolator RCCB Distribution Boards ACCL

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Refrigerated Air Dryers

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Refrigerated Air Dryers

FALCON SERIES 12 METAL CLAD

Refrigerated Air Dryers

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Refrigerated Air Dryer

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Datasheet - MZM 100 ST2-1P2PWREM-A

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

GREEN REFRIGERANT R-410A

Flopurge TS. Operation Manual

Datasheet - AZM 161SK-12/12RK-024

Datasheet - MZM 100 ST-SD2PREM-A

TOSVERT VF-S15. ATEX Guide. ATEX applications in explosive gas atmosphere or in the presence of combustible dust

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

Latch key safety limit switches Technical data

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Ordering Key. Dielectric strength

Datasheet - MZM 100 B ST2-SD2PREM-A

DATASHEET PolySwitch RKEF Devices

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

INSTALLATION INSTRUCTIONS

FALCON SERIES 12 METAL CLAD

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

CAST IRON ATMOSPHERIC BOILERS

INSTALLATION INSTRUCTIONS

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Datasheet - AZM 161SK-12/12RK-024

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

ISIS SAFETY SYSTEM Installation guide

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Datasheet - AZM ZRK 24 VAC/DC

INSTALLATION INSTRUCTIONS

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

VAMP 120 & 121. Arc flash detection units. Product picture

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

LMR Electric Fire Pump Controllers Features

GROUND FAULT PROTECTION PANELs. the power to protect GPD/GPFJ TYPES GPD, GPFJ, GPAD AND GPAFJ

Flostop TS D7E and A8E. Operation Manual

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Smart Classroom Design

* Consult factory on conditions for approval acceptability

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Specification Document. Heat-resisting Type Water Leakage Sensor FR-AD

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

Installation Instructions CS3 Three Phase Solid State Relay

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

DC POWER DISTRIBUTION BOARD

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7

1. Instruction. 1.5 Warranty Comar Condensatori S.p.A. guarantees its own products for twelve months from purchase

AQ 100 Series. Arc Flash Protection System

Transcription:

GE Industrial Solutions Moulded ase ircuit breakers Record* ge.com/ex/industrialsolutions

Record*.2 Introduction.3 Moulded ase ircuit reaker - thermal magnetic.4 Moulded ase ircuit reaker - thermal magnetic and leakage.5 General specifications Introduction and specifications Order codes Dimensions and applications Numerical index.1

Record* Moulded case circuit breaker Low-Voltage Moulded ase ircuit reaker (M) pplicable scope Record* has a rated insulation voltage of 1000V which is suitable for low-voltage distribution and motor protection application. vailable in five (5) breaker frame sizes with rated current from 16 up to 800. pplication Record* can be used for installation in the industrial segment, factories, residential and commercial sectors. The breakers are suitable to be installed in enclosures and switchboards. Features The Record* breakers are compact and have high breaking capacity. They can also be installed vertically or horizontally. ccessories are standardized for easy installation. The circuit breaker is compliant with IE 60947-2 standard. Standard operating conditions ltitude: Up to 2000m above sea level. mbient temperature: -5 ±40 (Operation of continuous 24 hours average not more than +35 ). Other atmospheric conditions: Salt spray, oil mist (moderate) & mold. Installation category of circuit breaker connecting to the main circuit: ategory III. Pollution level: Not exceeding class 3. The RecordTM circuit breakers should be utilised under normal ambient operating conditions. The breakers are not suitable to be installed in a potentially explosive and corrosive environment such as explosive chemical, corrosive gas and dust exposure..2

Moulded ase ircuit reaker - thermal magnetic IE60947-2 Standard ircuit breaker 125 250 400 630 800 Types S N S N S N H S N H N H Number of poles 3P/4P 3P/4P 3P/4P 3P/4P 3P/4P Rated insulation voltage Ui (Volts) 1000 1000 1000 1000 1000 Rated insulation impulse withstand voltage Uimp (Kilovolt) 8 8 8 8 8 Rated operating voltage (50/60Hz) Volts 400 400 400 400 400 Line protection device ategory of use Suitable as isolator Yes Rated current Ith=Ie at 40 125 250 400 630 800 Rated ultimate breaking capacity Icu (k) 400V 35 50 35 50 35 50 70 35 50 70 50 70 Rated service breaking capacity Ics (k) 400V 24.5 37.5 24.5 37.5 35 50 52.5 35 50 52.5 50 52.5 Endurance (O cycle) Mechanical 12500 12500 8000 8000 5000 Electrical (full current) 4000 5000 2500 2500 2500 Line thermal Trip unit magnetic trip Fixed Motor magnetic only trip Installation (1) ircuit breaker 125 250 400 630 800 Types S N S N S N H S N H N H Introduction Installation method onnection method Dimension (w x h x d) mm Weight (kg) Fixed Plug-in Front connection Rear connection Fixed front connect. 3P Fixed front connect. 3P S 92*150*100 N 92*150*118 S 105*150*122.5 N 105*150*139.5 Yes Yes 150*257*149.5 182*270*153 210*280*162 4P 122*150*118 105*150*139.5 198*257*149.5 270*240*153 280*280*162 S 1.34 N 1.71 S 1.84 N 2.08 5.57 6.85 9.57 4P 2.13 2.88 6.42 8.54 11.6 1) The circuit breaker, only allows upper incoming and lower outgoing, no reverse connection. 2) The interphase barrier is standard configuration of the circuit breaker..3

Record* Moulded case circuit breaker Moulded ase ircuit reaker - thermal magnetic and leakage IE60947-2 Standard ircuit breaker E125 E250 E400 E630 Type N N H H Number of poles Number of poles 3P/4P 3P/4P 3P/4P 3P/4P Rated insulation voltage Ui (Volts) 1000 1000 1000 1000 Rated insulation impulse withstand voltage Uimp (Kilovolt) 8 8 8 8 Rated operating voltage Volts (50/60Hz) 400 400 400 400 Line protection device ategory of use Suitable as isolator Yes Rated current Ith=Ie at 40 125 250 400 630 Rated ultimate short-circuit breaking capacity Icu (k) 400V 50 50 70 70 Rated service short-circuit breaking capacity Ics (k) 400V 37.5 37.5 52.5 52.5 Endurance (O cycle) Mechanical 12500 12500 8000 8000 Electrical (full current) 4000 5000 2500 2500 Line thermal magnetic trip Motor magnetic Fixed only trip Rated residual operating current I no Rated residual non-operating current I no Rated residual short-circuit making current I m Installation (1) Delay/non-delay 100/300/500 (m) 300/500/1000 (m) 1/2 I no 1/4 I no 300/500/1000 (m) 1 / 3 / 10 / 30 () ircuit breaker E125 E250 E400 E630 Type N N H H Installation method Fixed Yes Plug-in No Yes onnection method Front connection Rear connection Yes Dimension (w x h x d) mm Fixed front connect. 3P 150*92*87 150*105*103 150*257*149.5 210*280*162 4P 150*122*87 150*142*103 198*257*149.5 280*280*162 Weight (kg) Fixed front connect. 3P 1.9 3.28 6.22 10.1 4P 2.7 4.1 7.2 12.1 1) For the circuit breaker, only top incoming and bottom outgoing are allowed, reverse connection is not permitted. 2) The interphase barrier is standard configuration of the circuit breaker..4

General specifications Moulded ase ircuit reaker model explanation Record series circuit breaker model quick selection table Record series circuit breaker with leakage protection model quick selection table Product specification Product specification ircuit breaker E ircuit breaker with leakage protection Frame level Frame level reaking capacity reaking capacity Number of poles Number of poles 125 S = 35K 3 = 3P 250 N = 50K 4 = 4 pole 4 trips 400 H = 70K R = 4 pole 3 trips Trip Rated current Protection against earth leakage current 125 S = 35K 3 = 3P TM Line thermal 016-630 with delay - without alarm output 250 N = 50K 4 = 4 pole 4 trip magnetic without delay - without alarm output 400 H = 70K R = 4 pole 3 trips protection E with delay - with alarm output 630 M Magnetic only protection F without delay - with alarm output TM Trip Line thermal magnetic protection 630 M Magnetic only 800 protection For example: 125N3TM125 series circuit breaker Frame 125 50K 3P Line thermal magnetic trip 125 Rated current 016-800 General specifications For example: E125N3TM016 E series circuit breaker with leakage protection Frame 125 50K - 3P Line thermal magnetic trip 16 Leakage delay type Record* - General specifications Rated current 16 20 25 32 40 50 63 80 100 125 140 160 180 200 225 250 315 350 400 500 630 700 800 125 35K 3P - 50K 3P 4P 250 35K 3P - 50K 3P 4P 35K 3P - 400 50K 3P - 70K 3P 4P 35K 3P - 630 50K 3P - 70K 3P 4P 800 50K 3P - 70K 3P 4P Rated current 16 20 25 32 40 50 63 80 100 125 140 160 180 200 225 250 315 350 400 500 630 700 800 E125 50K 3P 4P E250 50K 3P 4P E400 70K 3P 4P E630 70K 3P 4P.5

Just rely on us

Record*.2 frame.6 E frame.12 ccessories.16 uxiliary contact - suitable for /E.16 larm contact.17 Under-voltage release.18 Electrical operators.19 Rotary handle.19 onnections for Ms / E.19 Operation and maintenance Introduction and specifications Order codes Dimensions and applications Numerical index.1

Record* frame 125 Thermal magnetic protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. Thermal magnetic type 35k S 50k N 16 125S3TM016 460001 - - - - 20 125S3TM020 460002 - - - - 25 125S3TM025 460003 - - - - 32 125S3TM030 460004 - - - - 40 125S3TM040 460005 - - - - 50 125S3TM050 460006 - - - - 63 125S3TM063 460007 - - - - 80 125S3TM080 460008 - - - - 100 125S3TM100 460009 - - - - 125 125S3TM125 460010 - - - - 16 125N3TM016 460050 125N4TM016 460104 125NRTM016 460013 20 125N3TM020 460051 125N4TM020 460105 125NRTM020 460014 25 125N3TM025 460052 125N4TM025 460106 125NRTM025 460015 32 125N3TM030 460053 125N4TM030 460107 125NRTM030 460016 40 125N3TM040 460054 125N4TM040 460108 125NRTM040 460017 50 125N3TM050 460055 125N4TM050 460109 125NRTM050 460018 63 125N3TM063 460056 125N4TM063 460110 125NRTM063 460019 80 125N3TM080 460057 125N4TM080 460111 125NRTM080 460020 100 125N3TM100 460058 125N4TM100 460112 125NRTM100 460021 125 125N3TM125 460059 125N4TM125 460113 125NRTM125 460022 frame 250 Thermal magnetic protection 35k S 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. 100 250S3TM100 460060 - - - - 125 250S3TM125 460061 - - - - 140 250S3TM140 460012 - - - - 160 250S3TM160 460011 - - - - 180 250S3TM180 460062 - - - - 200 250S3TM200 460063 - - - - 225 250S3TM225 460064 - - - - 250 250S3TM250 460065 - - - - 50k N 100 250N3TM100 460066 250N4TM100 460120 250NRTM100 460114 125 250N3TM125 460067 250N4TM125 460121 250NRTM125 460115 140 250N3TM140 460068 250N4TM140 460122 250NRTM140 460023 160 250N3TM160 460069 250N4TM160 460123 250NRTM160 460024 180 250N3TM180 460070 250N4TM180 460124 250NRTM180 460116 200 250N3TM200 460071 250N4TM200 460125 250NRTM200 460117 225 250N3TM225 460072 250N4TM225 460126 250NRTM225 460118 250 250N3TM250 460073 250N4TM250 460127 250NRTM250 460119.2

frame 400 Thermal magnetic protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. 35k S 225 400S3TM225 460074 - - - - 250 400S3TM250 460075 - - - - 315 400S3TM315 460076 - - - - 350 400S3TM350 460077 - - - - 400 400S3TM400 460078 - - - - 50k N 70K H 225 400N3TM225 460079 - - - - 250 400N3TM250 460080 - - - - 315 400N3TM315 460081 - - - - 350 400N3TM350 460082 - - - - 400 400N3TM400 460083 - - - - 225 400H3TM225 460084 400H4TM225 460133 400HRTM225 460128 250 400H3TM250 460085 400H4TM250 460134 400HRTM250 460129 315 400H3TM315 460086 400H4TM315 460135 400HRTM315 460130 350 400H3TM350 460087 400H4TM350 460136 400HRTM350 460131 400 400H3TM400 460088 400H4TM400 460137 400HRTM400 460132 Order codes frame 630 Thermal magnetic protection 35k S 50k N 70K H 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. 400 630S3TM400 460089 - - - - 500 630S3TM500 460090 - - - - 630 630S3TM630 460091 - - - - 400 630N3TM400 460092 - - - - 500 630N3TM500 460093 - - - - 630 630N3TM630 460094 - - - - 400 630H3TM400 460095 630H4TM400 460144 630HRTM400 460141 500 630H3TM500 460096 630H4TM500 460145 630HRTM500 460142 630 630H3TM630 460097 630H4TM630 460146 630HRTM630 460143 frame 800 Thermal magnetic protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. 50k N 630 800N3TM630 460098 - - - - 700 800N3TM700 460099 - - - - 800 800N3TM800 460100 - - - - 70K H 630 800H3TM630 460101 800H4TM630 460153 800HRTM630 460150 700 800H3TM700 460102 800H4TM700 460154 800HRTM700 460151 800 800H3TM800 460103 800H4TM800 460155 800HRTM800 460152.3

Record* frame 125 Magnetic only protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. Thermal magnetic type 35k S 50k N 16 125S3M016 460156 - - - - 20 125S3M020 460157 - - - - 25 125S3M025 460158 - - - - 32 125S3M030 460159 - - - - 40 125S3M040 460160 - - - - 50 125S3M050 460161 - - - - 63 125S3M063 460162 - - - - 80 125S3M080 460163 - - - - 100 125S3M100 460164 - - - - 125 125S3M125 460165 - - - - 16 125N3M016 460166 125N4M016 460236 125NRM016 460226 20 125N3M020 460167 125N4M020 460237 125NRM020 460227 25 125N3M025 460168 125N4M025 460238 125NRM025 460228 32 125N3M030 460169 125N4M030 460239 125NRM030 460229 40 125N3M040 460170 125N4M040 460240 125NRM040 460230 50 125N3M050 460171 125N4M050 460241 125NRM050 460231 63 125N3M063 460172 125N4M063 460242 125NRM063 460232 80 125N3M080 460173 125N4M080 460243 125NRM080 460233 100 125N3M100 460174 125N4M100 460244 125NRM100 460234 125 125N3M125 460175 125N4M125 460245 125NRM125 460235 frame 250 Magnetic only protection 35k S 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. 100 250S3M100 460176 - - - - 125 250S3M125 460177 - - - - 140 250S3M140 460178 - - - - 160 250S3M160 460179 - - - - 180 250S3M180 460180 - - - - 200 250S3M200 460181 - - - - 225 250S3M225 460182 - - - - 250 250S3M250 460183 - - - - 50k N 100 250N3M100 460184 250N4M100 460262 250NRM100 460254 125 250N3M125 460185 250N4M125 460263 250NRM125 460255 140 250N3M140 460186 250N4M140 460264 250NRM140 460256 160 250N3M160 460187 250N4M160 460265 250NRM160 460257 180 250N3M180 460188 250N4M180 460266 250NRM180 460258 200 250N3M200 460189 250N4M200 460267 250NRM200 460259 225 250N3M225 460190 250N4M225 460268 250NRM225 460260 250 250N3M250 460191 250N4M250 460269 250NRM250 460261.4

frame 400 Magnetic only protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. 35k S 225 400S3M225 460192 - - - - 250 400S3M250 460193 - - - - 315 400S3M315 460194 - - - - 350 400S3M350 460195 - - - - 400 400S3M400 460196 - - - - 50k N 70K H 225 400N3M225 460197 - - - - 250 400N3M250 460198 - - - - 315 400N3M315 460199 - - - - 350 400N3M350 460200 - - - - 400 400N3M400 460201 - - - - 225 400H3M225 460202 400H4M225 460280 400HRM225 460275 250 400H3M250 460203 400H4M250 460281 400HRM250 460276 315 400H3M315 460204 400H4M315 460282 400HRM315 460277 350 400H3M350 460205 400H4M350 460283 400HRM350 460278 400 400H3M400 460206 400H4M400 460284 400HRM400 460279 Order codes frame 630 Magnetic only protection 35k S 50k N 70K H 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. 400 630S3M400 460207 - - - - 500 630S3M500 460208 - - - - 630 630S3M630 460209 - - - - 400 630N3M400 460210 - - - - 500 630N3M500 460211 - - - - 630 630N3M630 460212 - - - - 400 630H3M400 460213 630H4M400 460291 630HRM400 460288 500 630H3M500 460214 630H4M500 460292 630HRM500 460289 630 630H3M630 460215 630H4M630 460293 630HRM630 460290.5

Record* E frame E125 Thermal-magnetic protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. Leakage type 50k N With delayed residual current device 16 E125N3TM016 460407 E125N4TM016 460587 E125NRTM016 460947 20 E125N3TM020 460413 E125N4TM020 460593 E125NRTM020 460953 25 E125N3TM025 460419 E125N4TM025 460599 E125NRTM025 460959 32 E125N3TM032 460425 E125N4TM032 460605 E125NRTM032 460965 40 E125N3TM040 460431 E125N4TM040 460611 E125NRTM040 460971 50 E125N3TM050 460437 E125N4TM050 460617 E125NRTM050 460977 63 E125N3TM063 460443 E125N4TM063 460623 E125NRTM063 460983 80 E125N3TM080 460449 E125N4TM080 460629 E125NRTM080 460989 100 E125N3TM100 460455 E125N4TM100 460635 E125NRTM100 460995 125 E125N3TM125 460461 E125N4TM125 460641 E125NRTM125 461001 With residual current device 16 E125N3TM016 460408 E125N4TM016 460588 E125NRTM016 460948 20 E125N3TM020 460414 E125N4TM020 460594 E125NRTM020 460954 25 E125N3TM025 460420 E125N4TM025 460600 E125NRTM025 460960 32 E125N3TM032 460426 E125N4TM032 460606 E125NRTM032 460966 40 E125N3TM040 460432 E125N4TM040 460612 E125NRTM040 460972 50 E125N3TM050 460438 E125N4TM050 460618 E125NRTM050 460978 63 E125N3TM063 460444 E125N4TM063 460624 E125NRTM063 460984 80 E125N3TM080 460450 E125N4TM080 460630 E125NRTM080 460990 100 E125N3TM100 460456 E125N4TM100 460636 E125NRTM100 460996 125 E125N3TM125 460462 E125N4TM125 460642 E125NRTM125 461002 With delayed residual current device and alarm 16 E125N3TM016E 460411 E125N4TM016E 460591 E125NRTM016E 460951 20 E125N3TM020E 460417 E125N4TM020E 460597 E125NRTM020E 460957 25 E125N3TM025E 460423 E125N4TM025E 460603 E125NRTM025E 460963 32 E125N3TM032E 460429 E125N4TM032E 460609 E125NRTM032E 460969 40 E125N3TM040E 460435 E125N4TM040E 460615 E125NRTM040E 460975 50 E125N3TM050E 460441 E125N4TM050E 460621 E125NRTM050E 460981 63 E125N3TM063E 460447 E125N4TM063E 460627 E125NRTM063E 460987 80 E125N3TM080E 460453 E125N4TM080E 460633 E125NRTM080E 460993 100 E125N3TM100E 460459 E125N4TM100E 460639 E125NRTM100E 460999 125 E125N3TM125E 460465 E125N4TM125E 460645 E125NRTM125E 461005 With residual current device and alarm 16 E125N3TM016F 460412 E125N4TM016F 460592 E125NRTM016F 460952 20 E125N3TM020F 460418 E125N4TM020F 460598 E125NRTM020F 460958 25 E125N3TM025F 460424 E125N4TM025F 460604 E125NRTM025F 460964 32 E125N3TM032F 460430 E125N4TM032F 460610 E125NRTM032F 460970 40 E125N3TM040F 460436 E125N4TM040F 460616 E125NRTM040F 460976 50 E125N3TM050F 460442 E125N4TM050F 460622 E125NRTM050F 460982 63 E125N3TM063F 460448 E125N4TM063F 460628 E125NRTM063F 460988 80 E125N3TM080F 460454 E125N4TM080F 460634 E125NRTM080F 460994 100 E125N3TM100F 460460 E125N4TM100F 460640 E125NRTM100F 461000 125 E125N3TM125F 460466 E125N4TM125F 460646 E125NRTM125F 461006.6

E frame E250 Thermal-magnetic protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. With delayed residual current device 100 E250N3TM100 461115 E250N4TM100 461259 E250NRTM100 461547 125 E250N3TM125 461121 E250N4TM125 461265 E250NRTM125 461553 140 E250N3TM140 461127 E250N4TM140 461271 E250NRTM140 461559 160 E250N3TM160 461133 E250N4TM160 461277 E250NRTM160 461565 180 E250N3TM180 461139 E250N4TM180 461283 E250NRTM180 461571 200 E250N3TM200 461145 E250N4TM200 461289 E250NRTM200 461577 225 E250N3TM225 461151 E250N4TM225 461295 E250NRTM225 461583 250 E250N3TM250 461157 E250N4TM250 461301 E250NRTM250 461589 50k N With residual current device 100 E250N3TM100 461116 E250N4TM100 461260 E250NRTM100 461548 125 E250N3TM125 461122 E250N4TM125 461266 E250NRTM125 461554 140 E250N3TM140 461128 E250N4TM140 461272 E250NRTM140 461560 160 E250N3TM160 461134 E250N4TM160 461278 E250NRTM160 461566 180 E250N3TM180 461140 E250N4TM180 461284 E250NRTM180 461572 200 E250N3TM200 461146 E250N4TM200 461290 E250NRTM200 461578 225 E250N3TM225 461152 E250N4TM225 461296 E250NRTM225 461584 250 E250N3TM250 461158 E250N4TM250 461302 E250NRTM250 461590 With delayed residual current device and alarm 100 E250N3TM100E 461119 E250N4TM100E 461263 E250NRTM100E 461551 125 E250N3TM125E 461125 E250N4TM125E 461269 E250NRTM125E 461557 140 E250N3TM140E 461131 E250N4TM140E 461275 E250NRTM140E 461563 160 E250N3TM160E 461137 E250N4TM160E 461281 E250NRTM160E 461569 180 E250N3TM180E 461143 E250N4TM180E 461287 E250NRTM180E 461575 200 E250N3TM200E 461149 E250N4TM200E 461293 E250NRTM200E 461581 225 E250N3TM225E 461155 E250N4TM225E 461299 E250NRTM225E 461587 250 E250N3TM250E 461161 E250N4TM250E 461305 E250NRTM250E 461593 Order codes With delayed residual current device and alarm 100 E250N3TM100F 461120 E250N4TM100F 461264 E250N4TM100F 461264 125 E250N3TM125F 461126 E250N4TM125F 461270 E250N4TM125F 461270 140 E250N3TM140F 461132 E250N4TM140F 461276 E250N4TM140F 461276 160 E250N3TM160F 461138 E250N4TM160F 461282 E250N4TM160F 461282 180 E250N3TM180F 461144 E250N4TM180F 461288 E250N4TM180F 461288 200 E250N3TM200F 461150 E250N4TM200F 461294 E250N4TM200F 461294 225 E250N3TM225F 461156 E250N4TM225F 461300 E250N4TM225F 461300 250 E250N3TM250F 461162 E250N4TM250F 461306 E250N4TM250F 461306.7

Record* E frame E400 Thermal-magnetic protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. With delayed residual current device 225 E400H3TM225 461673 E400H4TM225 461763 E400HRTM225 461943 250 E400H3TM250 461679 E400H4TM250 461769 E400HRTM250 461949 315 E400H3TM315 461685 E400H4TM315 461775 E400HRTM315 461955 350 E400H3TM350 461691 E400H4TM350 461781 E400HRTM350 461961 400 E400H3TM400 461697 E400H4TM400 461787 E400HRTM400 461967 Leakage type 70k H With residual current device 225 E400H3TM225 461674 E400H4TM225 461764 E400HRTM225 461944 250 E400H3TM250 461680 E400H4TM250 461770 E400HRTM250 461950 315 E400H3TM315 461686 E400H4TM315 461776 E400HRTM315 461956 350 E400H3TM350 461692 E400H4TM350 461782 E400HRTM350 461962 400 E400H3TM400 461698 E400H4TM400 461788 E400HRTM400 461968 With delayed residual current device and alarm 225 E400H3TM225E 461677 E400H4TM225E 461767 E400HRTM225E 461947 250 E400H3TM250E 461683 E400H4TM250E 461773 E400HRTM250E 461953 315 E400H3TM315E 461689 E400H4TM315E 461779 E400HRTM315E 461959 350 E400H3TM350E 461695 E400H4TM350E 461785 E400HRTM350E 461965 400 E400H3TM400E 461701 E400H4TM400E 461791 E400HRTM400E 461971 With residual current device and alarm 225 E400H3TM225F 461678 E400H4TM225F 461768 E400HRTM225F 461948 250 E400H3TM250F 461684 E400H4TM250F 461774 E400HRTM250F 461954 315 E400H3TM315F 461690 E400H4TM315F 461780 E400HRTM315F 461960 350 E400H3TM350F 461696 E400H4TM350F 461786 E400HRTM350F 461966 400 E400H3TM400F 461702 E400H4TM400F 461792 E400HRTM400F 461972 E frame E630 Thermal-magnetic protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. With delayed residual current device 400 E630H3TM400 462021 E630H4TM400 462075 E630HRTM400 462183 500 E630H3TM500 462027 E630H4TM500 462081 E630HRTM500 462189 630 E630H3TM630 462033 E630H4TM630 462087 E630HRTM630 462195 70k H With residual current device 400 E630H3TM400 462022 E630H4TM400 462076 E630HRTM400 462184 500 E630H3TM500 462028 E630H4TM500 462082 E630HRTM500 462190 630 E630H3TM630 462034 E630H4TM630 462088 E630HRTM630 462196 With delayed residual current device and alarm 400 E630H3TM400E 462025 E630H4TM400E 462079 E630HRTM400E 462187 500 E630H3TM500E 462031 E630H4TM500E 462085 E630HRTM500E 462193 630 E630H3TM630E 462037 E630H4TM630E 462091 E630HRTM630E 462199 With residual current device and alarm 400 E630H3TM400F 462026 E630H4TM400F 462080 E630HRTM400F 462188 500 E630H3TM500F 462032 E630H4TM500F 462086 E630HRTM500F 462194 630 E630H3TM630F 462038 E630H4TM630F 462092 E630HRTM630F 462200.8

E frame E125 Magnetic-only protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. 50k N With delayed residual current device 16 E125N3M016 460347 E125N4M016 460527 E125NRM016 460887 20 E125N3M020 460353 E125N4M020 460533 E125NRM020 460893 25 E125N3M025 460359 E125N4M025 460539 E125NRM025 460899 32 E125N3M032 460365 E125N4M032 460545 E125NRM032 460905 40 E125N3M040 460371 E125N4M040 462261 E125NRM040 460911 50 E125N3M050 460377 E125N4M050 460557 E125NRM050 460917 63 E125N3M063 460383 E125N4M063 460563 E125NRM063 460923 80 E125N3M080 460389 E125N4M080 460569 E125NRM080 460929 100 E125N3M100 460395 E125N4M100 460575 E125NRM100 460935 125 E125N3M125 460401 E125N4M125 460581 E125NRM125 460941 With residual current device 16 E125N3M016 460348 E125N4M016 460528 E125NRM016 460888 20 E125N3M020 460354 E125N4M020 460534 E125NRM020 460894 25 E125N3M025 460360 E125N4M025 460540 E125NRM025 460900 32 E125N3M032 460366 E125N4M032 460546 E125NRM032 460906 40 E125N3M040 460372 E125N4M040 460552 E125NRM040 460912 50 E125N3M050 460378 E125N4M050 460558 E125NRM050 460918 63 E125N3M063 460384 E125N4M063 460564 E125NRM063 460924 80 E125N3M080 460390 E125N4M080 460570 E125NRM080 460930 100 E125N3M100 460396 E125N4M100 460576 E125NRM100 460936 125 E125N3M125 460402 E125N4M125 460582 E125NRM125 460942 With delayed residual current device and alarm 16 E125N3M016E 460351 E125N4M016E 460531 E125NRM016E 460891 20 E125N3M020E 460357 E125N4M020E 460537 E125NRM020E 460897 25 E125N3M025E 460363 E125N4M025E 460543 E125NRM025E 460903 32 E125N3M032E 460369 E125N4M032E 460549 E125NRM032E 460909 40 E125N3M040E 460375 E125N4M040E 460555 E125NRM040E 460915 50 E125N3M050E 460381 E125N4M050E 460561 E125NRM050E 460921 63 E125N3M063E 460387 E125N4M063E 460567 E125NRM063E 460927 80 E125N3M080E 460393 E125N4M080E 460573 E125NRM080E 460933 100 E125N3M100E 460399 E125N4M100E 460579 E125NRM100E 460939 125 E125N3M125E 460405 E125N4M125E 460585 E125NRM125E 460945 Order codes With residual current device and alarm 16 E125N3M016F 460352 E125N4M016F 460532 E125NRM016F 460892 20 E125N3M020F 460358 E125N4M020F 460538 E125NRM020F 460898 25 E125N3M025F 460364 E125N4M025F 460544 E125NRM025F 460904 32 E125N3M032F 460370 E125N4M032F 460550 E125NRM032F 460910 40 E125N3M040F 460376 E125N4M040F 460556 E125NRM040F 460916 50 E125N3M050F 460382 E125N4M050F 460562 E125NRM050F 460922 63 E125N3M063F 460388 E125N4M063F 460568 E125NRM063F 460928 80 E125N3M080F 460394 E125N4M080F 460574 E125NRM080F 460934 100 E125N3M100F 460400 E125N4M100F 460580 E125NRM100F 460940 125 E125N3M125F 460406 E125N4M125F 460586 E125NRM125F 460946.9

Record* E frame E125 Magnetic-only protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. With delayed residual current device 100 E250N3M100 461067 E250N4M100 461211 E250NRM100 461499 125 E250N3M125 461073 E250N4M125 461217 E250NRM125 461505 140 E250N3M140 461079 E250N4M140 461223 E250NRM140 461511 160 E250N3M160 461085 E250N4M160 461229 E250NRM160 461517 180 E250N3M180 461091 E250N4M180 461235 E250NRM180 461523 200 E250N3M200 461097 E250N4M200 461241 E250NRM200 461529 225 E250N3M225 461103 E250N4M225 461247 E250NRM225 461535 250 E250N3M250 461109 E250N4M250 461253 E250NRM250 461541 Leakage type 50k N With residual current device 100 E250N3M100 461068 E250N4M100 461212 E250NRM100 461500 125 E250N3M125 461074 E250N4M125 461218 E250NRM125 461506 140 E250N3M140 461080 E250N4M140 461224 E250NRM140 461512 160 E250N3M160 461086 E250N4M160 461230 E250NRM160 461518 180 E250N3M180 461092 E250N4M180 461236 E250NRM180 461524 200 E250N3M200 461098 E250N4M200 461242 E250NRM200 461530 225 E250N3M225 461104 E250N4M225 461248 E250NRM225 461536 250 E250N3M250 461110 E250N4M250 461254 E250NRM250 461542 With delayed residual current device and alarm 100 E250N3M100E 461071 E250N4M100E 461215 E250NRM100E 461503 125 E250N3M125E 461077 E250N4M125E 461221 E250NRM125E 461509 140 E250N3M140E 461083 E250N4M140E 461227 E250NRM140E 461515 160 E250N3M160E 461089 E250N4M160E 461233 E250NRM160E 461521 180 E250N3M180E 461095 E250N4M180E 461239 E250NRM180E 461527 200 E250N3M200E 461101 E250N4M200E 461245 E250NRM200E 461533 225 E250N3M225E 461107 E250N4M225E 461251 E250NRM225E 461539 250 E250N3M250E 461113 E250N4M250E 461257 E250NRM250E 461545 With residual current device and alarm 100 E250N3M100F 461072 E250N4M100F 461216 E250NRM100F 461504 125 E250N3M125F 461078 E250N4M125F 461222 E250NRM125F 461510 140 E250N3M140F 461084 E250N4M140F 461228 E250NRM140F 461516 160 E250N3M160F 461090 E250N4M160F 461234 E250NRM160F 461522 180 E250N3M180F 461096 E250N4M180F 461240 E250NRM180F 461528 200 E250N3M200F 461102 E250N4M200F 461246 E250NRM200F 461534 225 E250N3M225F 461108 E250N4M225F 461252 E250NRM225F 461540 250 E250N3M250F 461114 E250N4M250F 461258 E250NRM250F 461546.10

E frame E400 Magnetic-only protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. With delayed residual current device 225 E400H3M225 461643 E400H4M225 461733 E400HRM225 461913 250 E400H3M250 461649 E400H4M250 461739 E400HRM250 461919 315 E400H3M315 461655 E400H4M315 461745 E400HRM315 461925 350 E400H3M350 461661 E400H4M350 461751 E400HRM350 461931 400 E400H3M400 461667 E400H4M400 461757 E400HRM400 461937 70k H With residual current device 225 E400H3M225 461644 E400H4M225 461734 E400HRM225 461914 250 E400H3M250 461650 E400H4M250 461740 E400HRM250 461920 315 E400H3M315 461656 E400H4M315 461746 E400HRM315 461926 350 E400H3M350 461662 E400H4M350 461752 E400HRM350 461932 400 E400H3M400 461668 E400H4M400 461758 E400HRM400 461938 With delayed residual current device and alarm 225 E400H3M225E 461647 E400H4M225E 461737 E400HRM225E 461917 250 E400H3M250E 461653 E400H4M250E 461743 E400HRM250E 461923 315 E400H3M315E 461659 E400H4M315E 461749 E400HRM315E 461929 350 E400H3M350E 461665 E400H4M350E 461755 E400HRM350E 461935 400 E400H3M400E 461671 E400H4M400E 461761 E400HRM400E 461941 With residual current device and alarm 225 E400H3M225F 461648 E400H4M225F 461738 E400HRM225F 461918 250 E400H3M250F 461654 E400H4M250F 461744 E400HRM250F 461924 315 E400H3M315F 461660 E400H4M315F 461750 E400HRM315F 461930 350 E400H3M350F 461666 E400H4M350F 461756 E400HRM350F 461936 400 E400H3M400F 461672 E400H4M400F 461762 E400HRM400F 461942 E frame E630 Magnetic-only protection 3 Poles 4 Poles 4 Trips 4 Poles 3 Trips In () at. no. Ref. no. at. no. Ref. no. at. no. Ref. no. Order codes With delayed residual current device 400 E630H3M400 462003 E630H4M400 462057 E630HRM400 462165 500 E630H3M500 462009 E630H4M500 462063 E630HRM500 462171 630 E630H3M630 462015 E630H4M630 462069 E630HRM630 462177 70k H With residual current device 400 E630H3M400 462004 E630H4M400 462058 E630HRM400 462166 500 E630H3M500 462010 E630H4M500 462064 E630HRM500 462172 630 E630H3M630 462016 E630H4M630 462070 E630HRM630 462178 With delayed residual current device and alarm 400 E630H3M400E 462007 E630H4M400E 462061 E630HRM400E 462169 500 E630H3M500E 462013 E630H4M500E 462067 E630HRM500E 462175 630 E630H3M630E 462019 E630H4M630E 462073 E630HRM630E 462181 With residual current device and alarm 400 E630H3M400F 462008 E630H4M400F 462062 E630HRM400F 462170 500 E630H3M500F 462014 E630H4M500F 462068 E630HRM500F 462176 630 E630H3M630F 462020 E630H4M630F 462074 E630HRM630F 462182.11

Record* ccessories Single auxiliary contact For breaker type at. no. Ref. no. at. no. Ref. no. Single auxiliary contact LEFT RIGHT 125/E125 125FS1L 460325 125FS1R 460029 250/E250 250FS1L 460328 250FS1R 460038 400/630/800 - E400/630 400FS1L 460333 400FS1R 460046 Dual auxiliary contact ccessories Dual auxiliary contact: LEFT RIGHT 125/E125 125FS2L 460326 125FS2R 460030 250/E250 250FS2L 460329 250FS2R 460039 400/630/800 - E400/630 400FS2L 460341 400FS2R 460047 Single alarm contact LEFT RIGHT 125/E125 125ML 460324 125MR 460025 250/E250 250ML 460327 250MR 460034 400/630/800 - E400/630 400ML 460332 400MR 460331 uxiliary and larm contacts module Single alarm contact LEFT RIGHT 125/E125 125FST1L 462219 125FST1R 462221 250/E250 250FST1L 462220 250FST1R 462222 Dual alarm contact 400/630/800 - E400/630 400FST2L 460340 400FST2R 460339 Shunt release Shunt release LEFT RIGHT 125/E125 230V E125SHTL 462223 125SHTR 460031 250/E205 230V E250SHTL 462224 250SHTR 460040 400/630/800 - E400/630 230V E400SHTL 462225 400SHTR 460048 Under-voltage release Under-voltage release LEFT 125/E125 230V 125UVRN 460032 125/E125 400V 125UVR8 460033 250/E250 230V 250UVRN 460041 250/E250 400V 250UVR8 460042 400/630 - E400 230V 400UVRN 460049 400/630 - E400 400V 400UVR8 462226 800/E630-230V 800UVRN 462227 800/E630-400V 800UVR8 462228 N Rotary handle Rotary handle 125/E125 125NRF1 460028 250/E250 250NRF1 460037 400/E400 3P 400NRF13 460338 400/E400 4P 400NRF14 460330 630NRF13 630NRF13 460344 630NRF14 630NRF14 460342 800NRF13 800NRF13 460045 800NRF14 800NRF14 460345 N.12 Notes: The last 2 digits of the product model 1. stands for round cover plate, 2. 3P stands for 3Poles breaker mounting, 3. 4P stands for 4Poles breaker mounting

ccessories Electric operating mechanism For breaker type at. no. Ref. no. 125/E125 230V 125FMFS 460299 250/E250 230V 250FMFS 460305 400/E400 230V 400FMF 460334 630 230V 630FMF 460343 800/E630 230V 800FMF 460346 Extended spreader For breaker type at. no. Ref. no. at. no. Ref. no. Spreader busbar: 3P 4P 125/E125 125SS3 460026 125SS4 460027 250/E250 250SS3 460035 250SS4 460036 400/E400 400SS3 460306 400SS4 460307 630 630SS3 460313 630SS4 460314 800/E630 800SS3 460043 800SS4 460044 Rear connections Order codes For breaker type at. no. Ref. no. at. no. Ref. no. Rear terminal: 3P 4P 125/E125 125R3 460294 125R4 460295 250/E250 250R3 460300 250R4 460301 400/E400 400R3 460308 400R4 460309 630 630R3 460315 630R4 460316 800/E630 800R3 460320 800R4 460321 Plug-in kit - Front connections For breaker type at. no. Ref. no. at. no. Ref. no. Front connections: 3P 4P 125 125FMFS 460299 250 250FMFS 460305 N 400/E400 400FMF 460334 630 630FMF 460343 Plug-in kit - Rear connections For breaker type at. no. Ref. no. at. no. Ref. no. Rear connections: 3P 4P 125 125DDF3 460296 125DDF4 460297 250 250DDF3 460302 250DDF4 460303 400/E400 400DDF3 460310 400DDF4 460311 630 630DDF3 460317 630DDF4 460318 800/E630 800DDF3 460322 800DDF4 460323.13

Record* ccessories - 125 250 400 630 800 ode ccessory 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 00 None - - - - - 10 Shunt release Low voltage Ms - E 20 Dual auxiliary contact 21 Single auxiliary contact 30 Under-voltage release 40 Shunt release + dual auxiliary contacts 41 Shunt release + single auxiliary contact 50 Shunt release + undervoltage release 60 Two groups of dual auxiliary contact 61 Two groups of single auxiliary contact 62 Double auxiliary cont. + single auxiliary contact 70 Under-voltage release + dual auxiliary contact 71 Under-voltage release + single auxiliary contact 08 larm contact 18 Shunt release + alarm contact 28 Dual auxiliary contact + alarm contact 38 Under-voltage release + alarm contact 48 Shunt release, single auxiliary + alarm contact - - - 58 Single auxiliary alarm contact - - - 68 Dual auxiliary contact + single auxiliary alarm contact 78 Under-voltage release, single auxiliary + alarm contact - Handle Legend Single auxiliary contact Left mounting Right mounting Dual auxiliary contact larm contact Shunt release Undervoltage release Single auxiliary alarm contact.14

ccessories - E ode ccessory 10 Shunt release 125 250 400 630 4P 4P 4P 4P 20 Dual auxiliary contact 21 Single auxiliary contact 30 Under-voltage release 40 Shunt release + dual auxiliary contacts 41 Shunt release + single auxiliary contact 60 Two groups of dual auxiliary contact 61 Two groups of single auxiliary contact 62 Double auxiliary cont. + single auxiliary contact 70 Under-voltage release + dual auxiliary contact 71 Under-voltage release + single auxiliary contact 08 larm contact 28 Dual auxiliary contact + alarm contact 58 Under-voltage release + alarm contact Order codes 68 Dual auxiliary contact + single auxiliary alarm contact Handle Legend Single auxiliary contact Left mounting Right mounting Dual auxiliary contact larm contact Shunt release Undervoltage release Single auxiliary alarm contact Note: E series 3P product could only use left-mounted single accessory..15

Record* Low voltage Ms / E uxiliary contact - suitable for /E uxiliary contacts and its combination The circuit breaker in "open" or "tripped" position 1 - haracteristics of auxiliary contacts ircuit breaker frame Rated thermal current Ith urrent consumption at 400V 125-800/E 125-630 3 0.30 Dual auxiliary contact Single auxiliary contact Technical parameters of the auxiliary contact - suitable for /E uxiliary contact wiring diagram F11 F14 F12 F24 F22 F14 F12 F14 Power supply Normally open F11 F21 F11 F12 Normally closed 2 - Electrical endurance ategory of use Making reaking Frequency Operating frequency (times/hour) Response time I/Ie U/Ue cosφ I/Ie U/Ue cosφ I/Ie U/Ue cosφ -15 10 1 0.3 1 1 0.3 0.05s 6050 360 D-13 1 1 6Pe 1 1 6Pe T0.95 3 - Operating threshold ategory of use Making reaking Frequency Operating frequency (times/hour) Response time I/Ie U/Ue cosφ I/Ie U/Ue cosφ I/Ie U/Ue cosφ -15 10 1.1 0.3 1.0 1.1 0.3 0.05s 10 120 D-13 1.1 1.1 6Pe 1.1 1.1 6Pe T0.95 larm contact uxiliary contact wiring diagram larm contact Ue=220V, Ith=3 ircuit breaker in "open" and "close" position ircuit breaker in "tripped" position 14 12 14 12 11 11 11 14 12 When the circuit breaker is closed and opened normally, the contact does not work. The contact changes its normal state only after tripping (or fault trip) occurs, with open state turning into closed, and closed state into open. fter the circuit breaker is reset, the contact returns to its original position..16

Under-voltage release The under-voltage release opens the circuit breaker when supply voltage drops to a value below 35% to70% to its rated voltage. When the power supply is equal or greater than 85% of the rated voltage, closing of the circuit breaker is allowed. haracteristics reaker type urrent consumption (m) Power consumption (W) ontrol circuit: 50/60Hz 230V 400V Note: the undervoltage must be be energized so that the circuit breaker ccan be reset and closed. Wiring diagram 400V 50/60Hz 230V 50/60Hz 400V 50/60Hz cosφ 125/E125 9.75 14.25 3.95 3.2275 250/E250 10.88 14.75 4.352 3.392 400/E400 9 11 3.6 2.53 630 8.5 11 3.4 2.53 800/E630 5 7.25 2 1.6675 P1 P2 Power input ccessories Shunt release The shunt release will trip the circuit breaker when the rated control voltage is between 70% and 110%. Wiring diagram urrent consumption of 1 Recommended diagram for D power supply Power input haracteristics reaker type urrent consumption (m) Power consumption (W) 400V 230V D 220V D 24V 400V 230V D 220V D 24V 125/E125 0.288 0.425 0.341 4 96.8 73 90.7 91.2 250/E250 0.313 0.412 0.341 3.87 11.2 68.8 90.7 85.3 400/E400 0.197 0.325 0.4 3.87 67 62.3 94.4 100 630 0.199 0.314 0.4 3.87 68 58.2 94.4 100 800/E630 0.538 0.898 1.134 5.22 16.3 153-120.17

Record* Electrical operators The wiring diagram of the external accessories of the breaker is displayed in the dotted box. Wiring diagram Low voltage Ms / E Power supply P1 P2 S1 S2 S4 External power supply M ontrol circuit S1 (closed) S2 (opened) Description S1, S2: Push-but ton (provided by user) : Wiring terminal P1, P2: External power supply Specifications: 50/60Hz, 230V, 400V D 24V, 100V, 220V haracteristics reaker type Operating current () H Operating power (W) Life span Height of the operator H (mm) 125/E125 0.5 14 20000 89.5 250/E250 0.5 14 20000 92 400/E400 2 35 10000 149 630/E630 2 35 10000 147 800 2 35 5000 151.18

Rotary handle - S1- Dimensions H 20 53 2-Ø5.5 Ø36 Note: Handle cover is round ircuit breaker 24 D MIN=50mm Mounting method and external dimension of rotary handle Rotary handle reaker Dimensions (mm) Mounting method H Metal 3P 4P S1-125 125/E125 54 104 30 S1-250 250/E250 55 143 35 S1-400 400/E400 82 194 137 185 Vertical S1-630 630 82 200 171 229 S1-800 800/E630 84 243 198 268 66 or 96 45 ccessories Note: Standard depth is 150mm onnections for Ms / E onnection of main terminals Rated urrent () 10 16 20 25 32 40 50 63 80 100 125 140 160 180 200 225 250 315 350 400 ross section of cable (mm 2 ) 1.5 2.5 4.0 6.0 10 16 25 35 50 70 95 120 185 240 onnection of insulated busbar and cables Rated urrent () ross section of cable Dimension of copper bar 1.5 2.5 4.0 6.0 Quantity ross section area (mm 2 ) Quantity Min. dimension (mm 2 ) 500 2 150 2 30 5 630 2 185 2 40 5 700, 800 2 240 2 50 5 (1) Note 1: Select a suitable connection accessory to the breaker termination and wiring requirement. Note 2: the copper bar termination to be connected with the proper spreader busbar. Operation and maintenance The features and accessories of the circuit breaker are set by the manufacturer. Do not adjust them during operation. The breakers are designed to isolate, switch and protect low-voltage distribution circuits. The trip units have been designed with the trip unit ratings indicated in mperes. To prevent unauthorized tampering of the breaker setting, each trip unit comes with a transparent, tamper-free cover. The circuit breakers are calibrated in the factory and no further calibration is required. The time current curves of the breakers are published in this catalogue..19

Just rely on us

Record* Low voltage Ms / E.22

Record* Power connections and installation.2 125 (S, N).3 250 (S, N).4 400 (S, N, H) 5 630 (S, N, H).6 800 (N, H).7 E Power connections and installation E.8 Installation with plug-in Introduction and specifications pplications.12 haracteristics and curves Order codes Dimensions and applications Numerical index.1

Power connections and installation Dimensions Power connections and installation - 125 (S, N) Front connection (3P, 4P) Mounting hole dimensions for front connection Type H H1 125S 68 100 125N 86 118 Rear connection (3P, 4P) Mounting hole dimensions for rear connection.2

Dimensions Power connections and installation - 250 (S, N) Front connection (3P, 4P) Dimensions and applications Mounting hole dimensions for front connection Type H H1 250S 88.5 122.5 250N 250 4P 105.5 139.5 Rear connection (3P, 4P) Mounting hole dimensions for rear connection.3

Record* Power connections and installation Dimensions Power connections and installation - 400 (S, N, H) Front connection (3P, 4P) Mounting hole dimensions for front connection Rear connection (3P, 4P) Mounting hole dimensions for rear connection.4

Dimensions Power connections and installation - 630 (S, N, H) Front connection (3P, 4P) Mounting hole dimensions for front connection Dimensions and applications Rear connection (3P, 4P) Mounting hole dimensions for rear connection.5

Record* Power connections and installation Dimensions Power connections and installation - 800 (N, H) Front connection (3P, 4P) Mounting hole dimensions for front connection Rear connection (3P, 4P) Mounting hole dimensions for rear connection.6

Dimensions Power connections and installation -E Front connection (3P, 4P) Mounting hole dimensions for front connection Dimensions and applications Overall dimension and mounting dimension reaker type L1 Manual mounting dimension (mm) Mounting method W L2 M H1 H2 H3 H4 3P 4P 1 Ø 1 E125 225 92 122 50 8 24 87 118-60 204 4.5 30 E250 252 107 142 65 8 24 105.5 139.5-70 213 4.5 35 E400 257 150 198 108 10 38 104.5 149.5-94 194 6.5 47 E630 280 198 280 108 12 40 112 159 44 140 243 7 70 Overall dimension of cover reaker type D E F E125 45 87.5 34 78 23 E250 45 102 40 92.5 25 E400 105 174 70 124 21 E630 105 204 84 182 22.7

Record* Dimensions Power connections and installation Installation with plug-in Through back plate reaker type L L1 L2 d D E H1 H2 125 65 60 90 41 94 6.5 160 90 30 18 56.2 250 74 70 100 45 110 6.5 179 105 35 20 73.2 400/E400 140 96 178 65 150 7 274 148 48 45 85 630 140 116 178 78 177 7 300 232 58 44 120 800/E630 143 140 181 82 213 7 311 210 70 44 125 Note: For 4 Pole breaker, dimension of E is added to, L2, and D..8

Dimensions Installation with plug-in Through panel Dimensions and applications reaker type L1 L2 d E 125 170 30 161 92 5 30 250 191 35 180 107 5 35 400/E400 290 48 276 150 6 48 630 316 58 302 176 6 58 800/E630 327 70 313 212 6 70 Note: For 4 Pole breakers 1.reaker frame 250 and below, dimension of E is added to, L2 2.reaker frame 400 and above, dimension of E is added. Dimension of remain the same..9

Record* Dimensions Power connections and installation Installation with plug-in On back plate reaker type L1 E d M H h 125 110 30 198 30 6.5 M4 57 28 250 150 35 223 35 8.5 M4 74 32 400/E400 244 48 326 48 10.5 M5 85 36 630 264 58 352 58 12.5 M6 120 64 800/E630 283 70 363 70 12.5 M6 125 67.10

Dimensions Installation with plug-in On DIN-rail Dimensions and applications reaker type E 125 65 60 30 250 74 70 35 400/E400 140 96 48 630 140 116 58 800/E630 143 140 70 Note: For 4 Pole breaker E is additional dimension to..11

Record* pplications Performance Ms - Series Rated current () Thermal release (ambient temperature +40 ) 1.05In (cold state) non-tripping time (h) 1.3In (hot state) tripping time (h) Tripping current of magnetic release () 10 In 63 1 1 10In ( 1±20%)* Line thermal magnetic 63<In 800 2 2 10In ( 1±20%) protection for the circuit 10 In 800 Heat dissipation reaker type 1.0In (cold state) non-tripping time (h) 2 2 Max. rated current () 1.2In (hot state) tripping time (h) 12In ( 1±20%) Heat dissipation (W) - 3P Notes Provides protection for the motor Front and rear connection Plug-in front connection Plug-in rear connection 125 (S, N)- (16-25) 25 40 42 45 125 (S, N) - (32-100) 100 35 37 40 125 (S, N) - (125) 125 39 42 43 250 (S, N) - (125-225) 225 62 66 70 250 (S, N) - (250) 250 67 73 73 400 (S, N, H) - (225-400) 400 115 120 125 630 (S, N, H) - (400-630) 630 187-200 800 (N, H) - (630-800) 800 262 - - Derating factor mbient temperature reaker type +40 +45 +50 +55 +60 125 1 0.96 0.91 0.85 0.78 250 1 0.94 0.94 0.9 0.86 400 1 0.95 0.89 0.82 0.75 630 1 0.94 0.88 0.82 0.76 800 1 0.94 0.87 0.8 0.72 Note: The derating factors above are measured under the rated current of the breaker frame..12

pplications urrent temperature characteristic - time/current characteristic 125 current temperature characteristic 125 S/N time/current characteristic curve pplications 250 current temperature characteristic 250 S/N time/current characteristic curve 400 current temperature characteristic 400 S/N/H time/current characteristic curve.13

Record* pplications - urrent temperature characteristic - time/current characteristic 630 current temperature characteristic 630 S/N/H time/current characteristic curve Ms - Series 800 current temperature characteristic 800 N/H time/current characteristic curve.14

pplications E Operating performance of trip Rated current () Thermal trip (ambient temperature +40 ) 1.05In (cold state) non-operating time (h) 1.3In (hot state) operating time (h) Operating current of electromagnetic trip () 10 In 63 1 1 10In ( 1±20%) 63<In 800 2 2 10In ( 1±20%) 16 In 800 1.0In (cold state) non-operating time (h) 2 2 Remarks Power distribution type 1.2In (hot state) operating time (h) 12In ( 1±20%) Motor protection type Reference table of power loss reaker type Making current () Total power loss of the four poles (W) Front and rear connection E125 Direct heating type (16-25) 25 40 E125 Indirect heating type (32-125) 125 39 E250 250 67 E400 400 115 E630 630 187 pplications Derating factor of change of ambient temperaturederatin Temperature Derating factor (In) reaker type +40 +45 +50 +55 +60 E125 1 0.96 0.91 0.85 0.78 E250 1 0.94 0.94 0.90 0.86 E400 1 0.95 0.89 0.82 0.75 E630 1 0.94 0.88 0.82 0.76 haracteristic curve of circuit breaker - E E125 current temperature characteristic E125 time/current characteristic curve.15

Record* pplications E - urrent temperature characteristic - time/current characteristic E250 current temperature characteristic E250 time/current characteristic curve Ms - leakage type Operating time t/s E400 current temperature characteristic E400 time/current characteristic curve Operating time t/s E630 current temperature characteristic E630 time/current characteristic curve Operating time t/s.16

pplications haracteristic curve of residual current protection of circuit breaker pplications.17

Record* haracteristic curve of residual current protection of circuit breaker Residual current operating time Ms - leakage type mbient temperature Residual current IΔt 2 IΔn 5 IΔn 10 IΔn Non-delay Maximum opening time (s) 0.2 0.1 0.04 0.04 Delay Maximum opening time (s) 0.5/1.15/2.15 0.35/1/2 0.25/0.9/1.9 0.25/0.9/1.9 Ultimate non-actuating time t (s) - 0.1/0.5/1 - - Residual current settings rotary switch schematic E125/250 E400 E125/250 E400/630 E630 Wiring diagram of alarm non-tripping module Note: P1, P2 are the terminal blocks of normally closed contact P3, P4 are the terminal blocks of normally open contact P5, P6 are the terminal blocks of 230V power supply.18

Record* Introduction and specifications Order codes.2 Numerical index by reference number.5 Numerical index by catalogue number Dimensions and applications Numerical index.1

Record* y reference number Numerical index Ref. no. at. no. Page 461067 E250N3M100.10 461068 E250N3M100.10 461071 E250N3M100E.10 461072 E250N3M100F.10 461073 E250N3M125.10 461074 E250N3M125.10 461077 E250N3M125E.10 461078 E250N3M125F.10 461079 E250N3M140.10 461080 E250N3M140.10 461083 E250N3M140E.10 461084 E250N3M140F.10 461085 E250N3M160.10 461086 E250N3M160.10 461089 E250N3M160E.10 461090 E250N3M160F.10 461091 E250N3M180.10 461092 E250N3M180.10 461095 E250N3M180E.10 461096 E250N3M180F.10 461097 E250N3M200.10 461098 E250N3M200.10 461101 E250N3M200E.10 461102 E250N3M200F.10 461103 E250N3M225.10 461104 E250N3M225.10 461107 E250N3M225E.10 461108 E250N3M225F.10 461109 E250N3M250.10 461110 E250N3M250.10 461113 E250N3M250E.10 461114 E250N3M250F.10 461211 E250N4M100.10 461212 E250N4M100.10 461215 E250N4M100E.10 461216 E250N4M100F.10 461217 E250N4M125.10 461218 E250N4M125.10 461221 E250N4M125E.10 461222 E250N4M125F.10 461223 E250N4M140.10 461224 E250N4M140.10 461227 E250N4M140E.10 461228 E250N4M140F.10 461229 E250N4M160.10 461230 E250N4M160.10 461233 E250N4M160E.10 461234 E250N4M160F.10 461235 E250N4M180.10 461236 E250N4M180.10 461239 E250N4M180E.10 461240 E250N4M180F.10 461241 E250N4M200.10 461242 E250N4M200.10 461245 E250N4M200E.10 461246 E250N4M200F.10 461247 E250N4M225.10 461248 E250N4M225.10 461251 E250N4M225E.10 461252 E250N4M225F.10 461253 E250N4M250.10 461254 E250N4M250.10 461257 E250N4M250E.10 461258 E250N4M250F.10 461499 E250NRM100.10 461500 E250NRM100.10 461503 E250NRM100E.10 461504 E250NRM100F.10 461505 E250NRM125.10 461506 E250NRM125.10 461509 E250NRM125E.10 461510 E250NRM125F.10 461511 E250NRM140.10 461512 E250NRM140.10 461515 E250NRM140E.10 461516 E250NRM140F.10 461517 E250NRM160.10 461518 E250NRM160.10 461521 E250NRM160E.10 461522 E250NRM160F.10 461523 E250NRM180.10 461524 E250NRM180.10 461527 E250NRM180E.10 461528 E250NRM180F.10 461529 E250NRM200.10 461530 E250NRM200.10 461533 E250NRM200E.10 461534 E250NRM200F.10 Ref. no. at. no. Page 461535 E250NRM225.10 461536 E250NRM225.10 461539 E250NRM225E.10 461540 E250NRM225F.10 461541 E250NRM250.10 461542 E250NRM250.10 461545 E250NRM250E.10 461546 E250NRM250F.10 461643 E400H3M225.11 461644 E400H3M225.11 461647 E400H3M225E.11 461648 E400H3M225F.11 461649 E400H3M250.11 461650 E400H3M250.11 461653 E400H3M250E.11 461654 E400H3M250F.11 461655 E400H3M315.11 461656 E400H3M315.11 461659 E400H3M315E.11 461660 E400H3M315F.11 461661 E400H3M350.11 461662 E400H3M350.11 461665 E400H3M350E.11 461666 E400H3M350F.11 461667 E400H3M400.11 461668 E400H3M400.11 461671 E400H3M400E.11 461672 E400H3M400F.11 461733 E400H4M225.11 461734 E400H4M225.11 461737 E400H4M225E.11 461738 E400H4M225F.11 461739 E400H4M250.11 461740 E400H4M250.11 461743 E400H4M250E.11 461744 E400H4M250F.11 461745 E400H4M315.11 461746 E400H4M315.11 461749 E400H4M315E.11 461750 E400H4M315F.11 461751 E400H4M350.11 461752 E400H4M350.11 461755 E400H4M350E.11 461756 E400H4M350F.11 461757 E400H4M400.11 461758 E400H4M400.11 461761 E400H4M400E.11 461762 E400H4M400F.11 461913 E400HRM225.11 461914 E400HRM225.11 461917 E400HRM225E.11 461918 E400HRM225F.11 461919 E400HRM250.11 461920 E400HRM250.11 461923 E400HRM250E.11 461924 E400HRM250F.11 461925 E400HRM315.11 461926 E400HRM315.11 461929 E400HRM315E.11 461930 E400HRM315F.11 461931 E400HRM350.11 461932 E400HRM350.11 461935 E400HRM350E.11 461936 E400HRM350F.11 461937 E400HRM400.11 461938 E400HRM400.11 461941 E400HRM400E.11 461942 E400HRM400F.11 462003 E630H3M400.11 462004 E630H3M400.11 462007 E630H3M400E.11 462008 E630H3M400F.11 462009 E630H3M500.11 462010 E630H3M500.11 462013 E630H3M500E.11 462014 E630H3M500F.11 462015 E630H3M630.11 462016 E630H3M630.11 462019 E630H3M630E.11 462020 E630H3M630F.11 462057 E630H4M400.11 462058 E630H4M400.11 462061 E630H4M400E.11 462062 E630H4M400F.11 462063 E630H4M500.11 462064 E630H4M500.11 462067 E630H4M500E.11 462068 E630H4M500F.11 Ref. no. at. no. Page 462069 E630H4M630.11 462070 E630H4M630.11 462073 E630H4M630E.11 462074 E630H4M630F.11 462165 E630HRM400.11 462166 E630HRM400.11 462169 E630HRM400E.11 462170 E630HRM400F.11 462171 E630HRM500.11 462172 E630HRM500.11 462175 E630HRM500E.11 462176 E630HRM500F.11 462177 E630HRM630.11 462178 E630HRM630.11 462181 E630HRM630E.11 462182 E630HRM630F.11 460025 125MR.12 460028 125NRF1.12 460029 125FS1R.12 460030 125FS2R.12 460031 125SHTR.12 460032 125UVRN.12 460033 125UVR8.12 460034 250MR.12 460037 250NRF1.12 460038 250FS1R.12 460039 250FS2R.12 460040 250SHTR.12 460041 250UVRN.12 460042 250UVR8.12 460045 800NRF13.12 460046 400FS1R.12 460047 400FS2R.12 460048 400SHTR.12 460049 400UVRN.12 460324 125ML.12 460325 125FS1L.12 460326 125FS2L.12 460327 250ML.12 460328 250FS1L.12 460329 250FS2L.12 460330 400NRF14.12 460331 400MR.12 460332 400ML.12 460333 400FS1L.12 460338 400NRF13.12 460339 400FST2R.12 460340 400FST2L.12 460341 400FS2L.12 460342 630NRF14.12 460344 630NRF13.12 460345 800NRF14.12 462219 125FST1L.12 462220 250FST1L.12 462221 125FST1R.12 462222 250FST1R.12 462223 E125SHTL.12 462224 E250SHTL.12 462225 E400SHTL.12 462226 400UVR8.12 462227 800UVRN.12 462228 800UVR8.12 460026 125SS3.13 460027 125SS4.13 460035 250SS3.13 460036 250SS4.13 460043 800SS3.13 460044 800SS4.13 460294 125R3.13 460295 125R4.13 460296 125DDF3.13 460297 125DDF4.13 460299 125FMFS.13 460300 250R3.13 460301 250R4.13 460302 250DDF3.13 460303 250DDF4.13 460305 250FMFS.13 460306 400SS3.13 460307 400SS4.13 460308 400R3.13 460309 400R4.13 460310 400DDF3.13 460311 400DDF4.13 460313 630SS3.13 460314 630SS4.13 460315 630R3.13 460316 630R4.13 Ref. no. at. no. Page 460317 630DDF3.13 460318 630DDF4.13 460320 800R3.13 460321 800R4.13 460322 800DDF3.13 460323 800DDF4.13 460334 400FMF.13 460343 630FMF.13 460346 800FMF.13 460001 125S3TM016.2 460002 125S3TM020.2 460003 125S3TM025.2 460004 125S3TM030.2 460005 125S3TM040.2 460006 125S3TM050.2 460007 125S3TM063.2 460008 125S3TM080.2 460009 125S3TM100.2 460010 125S3TM125.2 460011 250S3TM160.2 460012 250S3TM140.2 460013 125NRTM016.2 460014 125NRTM020.2 460015 125NRTM025.2 460016 125NRTM030.2 460017 125NRTM040.2 460018 125NRTM050.2 460019 125NRTM063.2 460020 125NRTM080.2 460021 125NRTM100.2 460022 125NRTM125.2 460023 250NRTM140.2 460024 250NRTM160.2 460050 125N3TM016.2 460051 125N3TM020.2 460052 125N3TM025.2 460053 125N3TM030.2 460054 125N3TM040.2 460055 125N3TM050.2 460056 125N3TM063.2 460057 125N3TM080.2 460058 125N3TM100.2 460059 125N3TM125.2 460060 250S3TM100.2 460061 250S3TM125.2 460062 250S3TM180.2 460063 250S3TM200.2 460064 250S3TM225.2 460065 250S3TM250.2 460066 250N3TM100.2 460067 250N3TM125.2 460068 250N3TM140.2 460069 250N3TM160.2 460070 250N3TM180.2 460071 250N3TM200.2 460072 250N3TM225.2 460073 250N3TM250.2 460104 125N4TM016.2 460105 125N4TM020.2 460106 125N4TM025.2 460107 125N4TM030.2 460108 125N4TM040.2 460109 125N4TM050.2 460110 125N4TM063.2 460111 125N4TM080.2 460112 125N4TM100.2 460113 125N4TM125.2 460114 250NRTM100.2 460115 250NRTM125.2 460116 250NRTM180.2 460117 250NRTM200.2 460118 250NRTM225.2 460119 250NRTM250.2 460120 250N4TM100.2 460121 250N4TM125.2 460122 250N4TM140.2 460123 250N4TM160.2 460124 250N4TM180.2 460125 250N4TM200.2 460126 250N4TM225.2 460127 250N4TM250.2 460074 400S3TM225.3 460075 400S3TM250.3 460076 400S3TM315.3 460077 400S3TM350.3 460078 400S3TM400.3 460079 400N3TM225.3 460080 400N3TM250.3.2