Toxic Gas Detection. Model F12. Toxic Gas Detection

Similar documents
Model D12. Digital Gas Transmitter

Model D12-IR. Digital Gas Transmitter...

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

UniSens. 2-Wire Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

UniSens 2-Wire Gas Transmitter

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Series D12 Toxic Gas Transmitter

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Series F12 Toxic Gas Transmitter

Series F12/D Toxic Gas Transmitter

Sieger Apex. Flexibility that meets your requirements

GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Frequently Asked Questions

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

GAS DETECTOR ST400EC PART.NO

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Two-Channel Gas Controller

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Series F12is Toxic Gas Transmitter

Toxic Smarter Transmitter Instruction Manual

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Warranty Registration

OLC(T) 100 FIXED GAS DETECTOR

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Model Q45P/R. ph/orp Monitor...

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

D12-17 % LEL Gas Transmiter

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Model Q45P/R. ph/orp Monitor...

Instructions TXL Series Oxygen and Toxic Gas Detectors 4/

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Stand Alone DYNAGARD SP Operation Manual

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

3M Oldham OLCT 100. Description. Fixed Gas Detector

GAS PLUS ALARM SYSTEM

M2A Transmitter Operator s Manual

MERIDIAN UNIVERSAL GAS DETECTOR

Honeywell EC-P2 EC-P2. Gas Detector CHARGE BATTERY WHEN NOT IN USE. Instruction Manual

The Art of Gas Detection

FX-SMT Series INSTRUCTION MANUAL P/N THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

M2 Transmitter Operator s Manual

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

IGD.CO.UK

SAFESITE Multi-Threat Detection System

SP-220. Features. Combustible handheld gas leakage detector

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

MSA Fixed Gas & Flame Detection for the Automotive Industry

ESD3000 ESD200 Combustible / Toxic Gas Detector

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

APPLICATION DATA SHEET

Carbon Monoxide CO Transmitter ADT-X3-1110

GLD-30 Gas Leak Detector

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Carbon Monoxide Transmitter

ALTAIR 5X Multigas Detector Product Specification

PortaSens III. Portable Gas Leak Detector Model D16. with Touch Sensitive Display

OPERATION AND MAINTENANCE MANUAL CONTROLLER 8000 ENVIRONMENTAL MONITORING AND CONTROL SYSTEM INDUSTRIAL SCIENTIFIC

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Gas Detection For Life

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

FIXED POINT SINGLE OR DUAL GAS MONITOR WITH DUAL ANALOG OUTPUTS

Universal Transmitter. Operations & Maintenance Manual

portable gas analyser

Series 9000 Total Hydrocarbon Analyzer

Fixed Gas & Flame Detection International Product Range Overview

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

INSTALLATION AND OPERATING INSTRUCTIONS

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

RIG RAT III. Wireless Multi-Point Gas Detection System. The Stand-Alone Solution

SAFESITE Sentry TM 24/7 Continuous Chemical Agent Detector. Instruction Manual

Products and performance

Monitores Personales. Personal Monitor

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Equipment. Model R002. Description. SF6 leak detector

Transcription:

Toxic Gas Detection Model F12 Toxic Gas Detection

Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form, it is designed for detection of a variety of toxic gases in hazardous area applications requiring IS devices. In addition, it is also well suited for all general purpose applications where toxic gas measurement is required. For IS installations, this transmitter is also available with a Hart communication option. F12 Transmitters use ATI s standard smart sensors for maximum flexibility. Sensors are easily exchanged and contain all calibration constants in sensor memory, eliminating the need for field calibration of transmitters. Sensors may be calibrated separately on the bench and then simply plugged into the transmitter. Calibration data is read into the transmitter automatically and no other adjustments are normally required. s s For general purpose gas detection applications, the F12 transmitter is also available in Non-IS versions. One version provides for easy interface to RS-485 networks using a standard MODBUS communication protocol. A second version provides a complete AC powered instrument with 3 alarm relays (SPST) available for external alarming. Model F12 With Optional Auto-Test Generator Optional Auto-Test Generator Smart Sensor Sensor Calibration Adapter Sensor Flow Cell

Specifications Gas Type: Customer selected from available sensor list. Sensor Type: Electrochemical for toxic gases and oxygen. User adjustable within limits of selected sensor module. Response Time: Sensor dependent. Accuracy: Generally ±10% of value, but limited by available calibration gas accuracy. Electronic: Repeatability: ±1% Electronic Linearity: ±0.5% Zero Drift: Less than 2% full scale per month, non-cumulative. Span Drift: Dependent on operating environment but generally less than 3% per month. Analog Output: Loop-powered 4-20 ma, 800 ohms maximum at 24 VDC Serial Interface: HART (1200 baud modem interface ) MODBUS (1200-9600,14.4k, 28.8k RS232 or RS485, s/w selectable) Power: 12-30 VDC, 25 ma maximum in loop-powered mode. 12 30 VDC, 200 ma maximum in 3-wire mode. 115 or 230 VAC, 50/60 Hz. Heated Sensor Power: 24 VDC connection, 250 ma max. (AC Units Supply Heater Power) Alarm Relay Option: Three SPST, 5 A @ 230 VAC resistive. Relay Coil: Programmable either normally energized or normally de-energized. Enclosure: Nema 4X poly carbonate. Controls: 4 program switches on front of transmitter. Operating Temperature: -30º to +60º C (Minimum temp. for O2 sensor is -10º C). Weight: 1 lb. (.5 Kg.) Seperated Sensor with Flow Cell Remote Sensor Option

Model F12 Toxic Gas Detection Features l Intrinsically Safe Design: Transmitters are designed for use in applications requiring intrinsically safe devices for safety purposes. l Interchangeable Sensors: Every transmitter will accept up to 45 different sensor modules, greatly reducing the need for multiple transmitter models. l Sensor Auto-Test: Gas generators permanently installed on the sensor verify sensor operation by providing a bump test of the sensor from daily to once a week. l Smart Sensor Modules: Plug-in sensors store calibration data, allowing sensors to be calibrated separately from the transmitter. This allows bench calibration (or factory calibration) of sensors to reduce the necessity for carrying calibration gas around the plant. l Alarm & Relay Option: A non-is version of the transmitter provides 3 integral alarm relays. Relays are programmable for setpoint, hysteresis, on-delay, off-delay, and other variables. Systems with alarms are available for operation from 12-30 VDC supplies or from 115 or 230 VAC power. l Serial Communication Interface: The IS version of the transmitter is available with HART communications. The HART protocol supports the HART Universal and Common Practice Commands at 1200 baud using the Bell 202 FSK modem standard. The non-is versions of the transmitter are available with MODBUS communications. The MODBUS protocol supports 9600 baud access to concentration and status information, and supports alarm setup and many other functions. Insertion Sensor with Duct Mount Adapter l LCD Graphics Display: Gas Concentrations are displayed in large, easy to read numbers. The display also provides alarm indication and complete menus for setting up operating parameters. l Internal Data Logger: Measured gas values are stored at user definable intervals and can be recalled when needed on the LCD display. Data can be downloaded using a HART or MODBUS interface. l Sensor Calibration History: Each time a sensor is zeroed or calibrated, the data is stored in memory. Calibration history can be recalled and sensor condition reviewed by operating personnel whenever necessary. l Non-Intrusive Operation: Operating functions such as calibration, alarm setup, alarm reset, data view, and setup options are all available using sealed front panel switches on the face of the Nema 4X transmitter enclosure. l Heated Sensor Option: For use in applications where condensation is a problem, this heater option keeps the sensor above the dew point to eliminate loss of sensitivity due to moisture blockage on the sensor face. l Output Simulation: Transmitter analog output can be set to user definable values and relay outputs can be set to specific states for complete simulation of detection system operation. Output and alarms may also be inhibited for maintenance and calibration.

Available Series F12 Transmitter Electrochemical Sensors Note: The correct generator part number used to provide the Auto-Test feature for a specific sensor is shown in parenthesis after the sensor price. Gas & Range. A/T Gen. No.. 00-1000* Bromine, 0-1/5 PPM (2 PPM Standard) (00-1538) 00-1001* Bromine, 0-5/100 (20 PPM Standard) (00-1538) 00-1002* Chlorine, 0-1/5 PPM (2 PPM Standard) (00-1538) 00-1003* Chlorine, 0-5/100 (20 PPM Standard) (00-1538) 00-1004* Chlorine Dioxide, 0-1/5 PPM (2 PPM Standard) (00-1538) 00-1005* Chlorine Dioxide, 0-5/100 (20 PPM Standard) (00-1538) 00-1359 Chlorine Dioxide, 200/1000 PPM (1000 PPM Standard) 00-1425* Chlorine Dioxide, 1/5 PPM (low Cl2 response) (00-1538) 00-1006* Fluorine, 0-1/5 PPM (2 PPM Standard) (00-1538) 00-1007* Fluorine, 0-5/100 (20 PPM Standard) (00-1538) 00-1008* Ozone, 0-1/5 PPM (2 PPM Standard) (00-1538) 00-1009* Ozone, 0-5/100 PPM (20 PPM Standard) (00-1538) 00-1358 Ozone, 200/1000 PPM (1000 PPM Standard) 00-1010* Ammonia, 0-50/500 PPM (200 PPM Standard) (00-1539) 00-1011 Ammonia, 0-500/2000 PPM (1000 PPM Standard) 00-1012* Carbon Monoxide, 0-50/1000 PPM (200 PPM Standard) (00-1540) 00-1013 Hydrogen, 0-1/10% (4% Standard) 00-1014 Oxygen, 0-5/25% (25% Standard) 00-1015 Phosgene, 0-1/5 PPM (2 PPM Standard) 00-1016 Phosgene, 0-5/100 PPM (100 PPM Standard) 00-1017* Hydrogen Chloride, 0-10/200 PPM (20 PPM Standard) (00-1541) 00-1018* Hydrogen Cyanide, 0-10/200 PPM (20 PPM Standard) (00-1542) 00-1019* Hydrogen Fluoride, 0-10/200 PPM (20 PPM Standard) (00-1538) 00-1020* Hydrogen Sulfide, 0-10/200 PPM (50 PPM Standard) (00-1541) 00-1021 Nitric Oxide, 0-50/500 PPM (200 PPM Standard) 00-1022* Nitrogen Dioxide, 0-10/200 PPM (20 PPM Standard) (00-1538) 00-1023* Sulfur Dioxide, 0-10/500 PPM (20 PPM Standard) (00-1542) 00-1024 Arsine, 0-500/2000 PPB (1000 PPB Standard) 00-1025 Arsine, 0-10/200 PPM (10 PPM Standard) Auto-Test Gas Generators 00-1026 Diborane, 0-500/2000 PPB (1000 PPB Standard) 00-1538 E18-11 Chlorine gas generator 00-1539 E18-15 Ammonia gas generator 00-1027 Diborane, 0-10/200 PPM (10 PPM Standard) 00-1540 E18-16 Carbon Monoxide gas generator 00-1028 Germane, 0-500/2000 PPB (1000 PPB Standard) 00-1541 E18-24 Hydrogen Sulfide gas generator 00-1029 Germane, 0-10/200 PPM (10 PPM Standard) 00-1542 E18-27 Sulfur Dioxide gas generator 00-1030 Hydrogen Selenide, 0-500/2000 PPB (1000 PPB Standard) 00-1031 Hydrogen Selenide, 0-10/200 PPM (10 PPM Standard) 00-1032 Phosphine, 0-500/2000 PPB (1000 PPB Standard) 00-1033 Phosphine, 0-10/200 PPM (10 PPM Standard) 00-1034 Phosphine, 0-200/2000 PPM (1000 PPM Standard) 00-1035 Silane, 0-10/200 PPM (10 PPM Standard 00-1036* Iodine, 0-1/5 PPM (2 PPM Standard) (00-1538) 00-1037* Iodine, 0-5/100 PPM (20 PPM Standard) (00-1538) 00-1038* Acid Gases, 0-10/200 PPM (20 PPM Standard) (00-1538) 00-1039* Ethylene Oxide, 0-20/200 PPM (20 PPM Standard) (00-1540) 00-1040* Formaldehyde, 0-20/200 PPM (20 PPM Standard) (00-1540) 00-1041 Hydrogen, 0-500/2000 PPM (2000 PPM Standard) 00-1042* Hydrogen Peroxide, 0-10/100 PPM (20 PPM Standard) (00-1542) 00-1169 Hydrogen Peroxide, 200/2000 PPM (1000 Standard) 00-1043 Alcohol, 0-50/500 PPM (200 PPM Standard) 00-1044 Alcohol, 0-500/2000 PPM (2000 PPM Standard) 00-1057 Acetylene, 200/2000 PPM (500 PPM Standard) 00-1181 NoX, 0-50/500 PPM (200 PPM Standard) 00-1349 Formaldehyde, 500/2000 PPM (1000 Standard) 00-1450* Dimethylamine (DMA), 100/200 PPM (100 PPM Standard) 00-1455* Hydrogen Bromide, 10/200 PPM (20 PPM Standard) (00-1539) 00-1516 HC Sensor (Specify Gas - Consult Factory) (00-1538)

Ordering Information Model F12-A-B-C-D Gas Transmitter F12 transmitters are designed to use electrochemical sensors only. This transmitter uses the same sensors as those used in the PortaSens II and D12 series products. This transmitter series does not support catalytic bead or IR sensors. Specify transmitter first and them select the sensor and the Auto-Test generator if required. Suffix A: Transmitter Type 1 2-wire only (IS design only without heated sensor) 2 Non-IS system for RS-485 communication 3 Non-IS system, 115 VAC, 50/60 HZ with alarms 4 Non-IS system, 230 VAC, 50/60 HZ with alarms 5 Non-IS system, 12-30 VDC with alarms Suffix B: Sensor Holder Style 1 Integral sensor holder 2 Remote sensor holder with junction box (order 31-0162 interconnect cable below) 3 Integral heated sensor holder 4 Remote heated sensor holder with junction box (see note 1) 5 Duct mount sensor holder with 25 extension cable (requires 00-1388 Adapter) 6 Remote sensor holder with 6 foot cable Suffix C: Sensor Auto-Test 1 No Auto-Test Generator Holder 2 With Auto-Test Generator Holder Suffix D: Digital Output 1 None 2 Hart interface 3 Modbus interface (Requires option 2 or 3 under suffix A) Note 1: Interconnection of remote heated sensor holder requires 2 interconnect cable, the 31-0162 for the sensor and the 31-0008 2-conductor cable for the heater. Accessories 00-1056 Calibration adapter 00-1251 Flowcell assembly 00-0981 Sensing module keeper for 4 sensors 00-1388 Duct sensor adapter, 1½ MNPT 31-0162 Remote Interconnect Cable, specify length, max. 50 ft. 31-0008 2-conductor, unshielded interconnect cable. Represented By: DS F12 (02/10) Analytical Technology, Inc. 6 Iron Bridge Drive, Collegeville, PA 19426 Phone: (610) 917-0991 Toll-Free: 800-959-0299 Fax: (610) 917-0992 E-Mail: sales@analyticaltechnology.com Analytical Technology Unit 1 & 2 - Gateway Business Park Delph New Road Delph, Saddleworth OL3 5DE Phone: +44 (0) 1457 873 318 Fax: +44 (0) 1457 874 468 E-Mail: sales@atiuk.com www.analyticaltechnology.com