Space bar opening: : 3/8 to 2 (1 to 60mm) Width: 1.3 to 6.56 (400mm to 2000mm)

Similar documents
Technical Memorandum. 1 Summary Findings and Conclusions. SMCSD Headworks, Primary and Secondary Treatment Pre-Design

Pretreatment Applications. John Meunier Products and Solutions WATER TECHNOLOGIES

SAVI MultiRake Perforated Plate Screen

Pretreatment. Complete Line of John Meunier Products and Solutions WATER TECHNOLOGIES

Huber Technology Superior craftsmanship since 1872

HEADWORKS PERFORATED PLATE FILTER SCREEN ROTARY DRUM SCREEN IN CHANNEL PERFORATED DRUM SCREEN

LIQUID/SOLID SEPARATION

Solids Handling and Reduction Choices for Wastewater Applications

Hazen and Sawyer 545 Mainstream Drive, Suite 320 Nashville, TN

LAKESIDE SCREW PUMPS. Flexibility. Proven Design. Trouble-Free Operation.

OPERATION & MAINTENANCE

Auger Monster. Features & Benefits Dual Shafted Grinder. Modular Headworks System. The Only One That s All-in-One.

Screening and Grit Removal presented by Doug McCord EnQuip.com

SCREENING PROCESSING EQUIPMENT

Screen and Trash Rakes. MUHR Hydraulic and Cable Operated Raking Mechanisms

Columbus Southerly WWTP New Headworks June Presented by: Chad Dunn, PE Malcolm Pirnie, Inc.

PRECAST CONCRETE. Never Looked So Good!

Inline Sludge Screens Municipal and Industrial Applications

Channel Monster. The Alternative to Screens for Pump Stations. Features & Benefits. Protect Pumps & Reduce Downtime.

Channel Monster. The Alternative to Screens for Pump Stations. Features & Benefits. Protect Pumps & Reduce Downtime.

Best Environmental Management Practices

8U Vertical Server Cabinet - 30 in. depth

Tel Group

OWEA Biosolids Specialty Workshop December 3, 2015

Biosolids Technology Fact Sheet Recessed-Plate Filter Press

HUBER Grit Separation Systems

HUBER Grit Separation Systems

Telecab17 Residential Elevator OWNER S MANUAL

Macerator Grinders Pipeline and Channel Series


Biosolids and Composting in Midwest City, OK

Fifth Annual Waste Treatment Symposium, September Kelly Brown, BDP Industries, Inc.

BWS 1000 OPERATION AND MAINTENANCE MANUAL

INFLOW & INFILTRATION REPORT

THE CLEAR CHOICE FOR CLEANING

OPERATION & MAINTENANCE

Cooking Equipment. Who we are

Comparison of Options for Biosolids Dewatering

48 MaxxAir Portable Evaporative Cooler Owner s Manual

EMD - Rotary Drum Screens

MOBILE FOOD SERVICE ESTABLISHMENT CONSTRUCTION, EQUIPMENT AND OPERATION GUIDELINES

R O T O - J E T O F A M E R I C A C O M P A N Y, I N C.

POWERSEWER ENGINEERED PRODUCTS. franklinengineered.com

Edmonton is a world-class composting city State-of-the-art compost facility draws visitors from around the world

OPERATION & MAINTENANCE

Portable Dust Collection Systems

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

Improving Efficiency of Dewatering Alternatives to Conventional Dewatering Technologies

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

Moba Coenraadts Tray Washer Overview on the CTW 3250 and CTW 6500

VERSA Rotary Drum Screens

COMMERCIAL ELECTRIC DRYER MODELS: MLE27PDBYW1 (White) 01/19/ Maytag Part No. W Rev. A

hinged tops or hinged doors.

TECHNICAL MANUAL Admiral 44-4 Addendem

Confined Space Ventilation equipment

TECHNICAL MANUAL TRAY DRYER

Millennium Series In-Ground Trash Cans and Recycling Containers Prepared for and Presented by Rob Mitchell and Randy Unrau

DELUXE OPERATIONAL MANUAL

MODEL CMA-130VL PARTS MANUAL Rev 1.00

Institutions NUMBER: Food Service Safety And Sanitation

Modernizing your Sewer Flow Monitoring Technology

The Whole Ball of Wax.. Or water & energy conservation integrated into the sustainability-marketing picture.

Plenum Fans. Model HPA. Direct Drive

Celebrating over 30 years of excellence in manufacturing ultrasonic cleaning equipment, electropolishing equipment and associated chemistries

Model BX-903, BX-904 and BX-906 Environmental Enclosure For BAM-1020 Operation Manual

BASIL 6000 TUNNEL CAGE WASHER

VARIABLE SPEED GRINDER OWNER S MANUAL R MANUAL VERSION SERIAL #

VariCool VAV Engineering Guide

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

<li>collect washwater in a designated area. Recycle washwater, or discharge to the sanitary sewe

Prohibitions on using

TITAN SYSTEM ENGINEERING DATA SHEET TITAN HXS

IWEA SAFETY COMMITTEE PLANT SAFETY AUDIT (Revised 03/2016)

WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.

- Sewage and Sludge Pumps

HUBER Grit Separation Systems

Rollair. Rotary Screw Compressors ROLLAIR AND ROLLAIR V

Control Panel For Water Wash Hoods AM2

88MLV Series Open Channel Modular UV Systems

C44A/C44AW DISHWASHER

Imperviousness & Runoff

ZEROwaste HX PERC SYSTEM USER MANUAL. AIR QUALITY LABORATORIES Seattle, Washington

WASHING AND DISINFECTION APPLICATIONS GRIDPATH. Manual boot washer (550101) with automatic chemical supply (550102).

LONDON GROVE TOWNSHIP MUNICIPAL AUTHORITY FOG PROGRAM BEST MANAGEMENT PRACTICES

Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood

Wheelbarrow Mixer Operations Manual

Telecab Residential Elevator OWNER S MANUAL

EASY FEED LITE FRICTION FEEDER OPERATOR MANUAL. Rev

VEGETABLE SLICER NO. 48 CHEESE GRATER No. 49 USER AND MAINTENANCE MANUAL

Glass and Dishwashers AMX / AUX Series

Article 1302: SOLID WASTE AND LITTERING (Adopted 06/12/2006)

New Features! More Benefits!

RS Chimney Fan for Solid Fuel Applications

Food Service Facilities

POLE BRIDGE ROAD NEAR FIVE LOT FARM

Version 7 1/ LXP

Version 7 1/ LX

EIMCO FlexKlear Inclined Plate Settlers Inclined Plate Settlers have a long-standing reputation as efficient water clarification tools with two unfort

Grease Control Device Maintenance Recordkeeping

Trash Compactors and Dumpsters: Eliminating a Major Source of Stormwater Pollution

Transcription:

Performances Applications: Municipal & Industrial Flow capacity: up to 60mgd Space bar opening: : 3/8 to 2 (1 to 60mm) Design Screentec is customized based on specifications and/or structural constraints. Below are some guidelines of the design requirements. MATERIALS 304 or 316 stainless steel Surface treatment: Scouring, Passivation T.I.G. welding techniques SPACE REQUIREMENTS - FOOTPRINT Depth: up to 50 (15m) Width: 1.3 to 6.56 (400mm to 2000mm) Discharge height: 4 (1200mm) Installation angle: 90 MOTOR CHARACTERISTICS Absorbed power: ¾hp (0.56 KW) Voltage: 240 or 480 VAC Frequency: 60 Hz Aqualitec Corp. - 610 W Carob Street, Compton, CA 90220 1-877-278-2214. Fax (323) 732 2815. www.aqualitec.com

Screentec: The Mechanical Vertical Bar Screen Solution for Headworks, Lift Stations, Deep Wells and Manholes. By Aqualitec. Aqualitec Corp. - 610 W Carob Street, Compton, CA 90220 1-877-278-2214. Fax (323) 732 2815. www.aqualitec.com

Operating Mode 1 The Rake, set up on a sturdy belt, moves downward following 2 guide rails on each side of the frame. 4 3 2 Bar Screen 1 2 The Rake collects all the screenings stuck by the bar screen. 3 The Rake goes up, lifting up all the collected screenings. 4 Screenings are ejected in a washer compactor Compactec or in a dumpster. Rake The mechanical vertical bar screen Screentec can be installed in many applications including Headworks, Lift Stations, Deep Wells and Manholes. Due to its vertical design, Screentec can retrofit any kind of structure with minimal or no changes.

Features & Benefits 1. Vertical Design 2. Minimal & Easy Maintenance With a 90 angle installation, Screentec can fit in any kind of structure, up to 50 deep. Screentec does not have moving parts at the bottom of the frame. The weekly maintenance will only consist of a visual check of the top frame. The access is safe since operators can open the secure hood from the grate level. 3. Odor Control The frame of the vertical bar screen is completely enclosed. Adding a washer compactor Compactec with a bagger system will maintain total odor control. Screentec can be installed in residential areas without risk of odor complaints.

Deep Well 1. Mendocino, California Top view Inside view Context: The Headwork s structure is complex with a 12 deep well. Inside, 2 narrow channels (1 communitor - 1 grinder) dealing with a peak flow of 1mgd. Design view Current view No Structural Changes Solution: With its vertical design, Screentec fits into narrow and deep structures such as the Mendocino deep well.

Lift Station 2. The Lower Township, New Jersey Top view Inside view Context: This lift station has an inlet pipe and a manual rack. Daily maintenance is required to manually remove the debris. Design view Upcoming installation, June 2012 No Manual Labor Solution: Screentec will be installed right at the influent inlet. No structural changes are required and the existing manual rack will be used as the overflow back up.

Headworks 3. City of St. John s, Washington Headworks view Headworks view Context: The City of St John s has to comply with the Biosolids Rule. They need to replace the grinder by a mechanical bar screen that will remove all the debris from the influent. Solution: Screentec fits right into the existing channel. Design view, Upcoming installation, July 2012 Collects All Debris

Manhole 4. City of Orange, France Top view Inside view Context: With no screening operation, the pumps of the WasteWater Treatment Plant are clogged and damaged, resulting on a great deal of manual work and maintenance cost. Solution: To protect the pumps, the only solution was to install the mechanical bar screen ahead of their pumps. Screentec is installed into their manhole, collecting all the debris prior to reaching the pumps. Current view Protects Pumps from Rags