Villalobos, David From: Sent: To: Subject: Categories: Hodosy-McFaul, Anita Monday, July 01, 2013 2:35 PM Villalobos, David FW: val verde Purple Category From: Chris Belanger [mailto:chris@cbrdesign.com] Sent: Tuesday, June 25, 2013 12:02 PM To: Hodosy-McFaul, Anita Subject: val verde Hi Anita, Here s the info on the site: ADDRESS: 2549 Sycamore Canyon Road Montecito, CA 93108 APN: 011 120 003 ZONING: 5 E 1 The project scope is: 1. INSTALL (N) 800A 120v/280v 3Ø 4W MAIN SWITCHBOARD 2. INSTALL (N) 600A 120v/280v 3Ø 4W DISTRIBUTION PANEL TO (E) 400A PANEL IN BASEMENT 3. INSTALL UNDERGROUND LINES CONNECTING THE (N) MAIN SWITCHBOARD TO THE (N) DISTRIBUTION PANEL. TRENCHING NOTES: 1. LANDSCAPED AREAS: TRENCHING THROUGH LANDSCAPED AREAS WILL BE 6" WIDE AND 40" DEEP. THE PATH WILL BE SELECTED TO MINIMIZE IMPACT ON EXISTING PLANTINGS. PLANTINGS WILL BE REMOVED ONLY AS REQUIRED AND RE PLANTED IN PLACE. SHOULD REPLACEMENT PLANTINGS BE REQUIRED FOR ANY REASON, THEY WILL MATCH THE TYPE AND SIZE OF THE REMOVED PLANT. 2. WALKWAYS: EXISTING WALKWAYS ARE COMPOSED OF BRICK OVER SAND WITHOUT GROUT. WHERE THE LINE RUNS BELOW EXISTING WALKWAYS, 24" X 24" SECTIONS WILL BE REMOVED EVERY 10' TO ALLOW TUNNELING BETWEEN. BRICKS WILL BE RE INSTALLED AFTER INSTALLATION OF THE NEW ELECTRICAL LINES. The electrician has indicate that the conduit has been installed through the landscaped and walkway areas reviewed during the recent site inspection. Let me know if more information or details are needed. Thanks! Chris 1
Chris Belanger Chris Belanger Residential Design 501 Chapala Street Suite F Santa Barbara, CA 93101 C: 805 252 8260 www.facebook.com/cbrdesign 2
VAL VERDE ESTATE COVER SHEET VAL VERDE ESTATE 2549 Sycamore Canyon Road Montecito, CA 93108 PROPERTY INFORMATION ADDRESS: 2549 Sycamore Canyon Road Montecito, CA 93108 APN: 011-120-003 ZONING: 5 E-1 LOT AREA: OWNER SURFDOG VENTURES, LLC 2549 SYCAMORE CANYON RD SANTA BARBARA, CA 93108 DESIGNER CHRIS BELANGER RESIDENTIAL DESIGN MAIL: 1187 COAST VILLAGE ROAD SUITE 1-203 MONTECITO, CA 93108 PHONE: 805 259 4525 FAX: 805 456 0413 EMAIL: CHRIS@CBRDESIGN.COM DESIGNER CHRIS BELANGER RESIDENTIAL DESIGN 1187 COAST VILLAGE ROAD SUITE 1-203 MONTECITO, CA 93108 805 259 4525 PROJECT DESCRIPTION 1. INSTALL (N) 800A 120v/280v 3Ø 4W MAIN SWITCHBOARD 2. INSTALL (N) 600A 120v/280v 3Ø 4W DISTRIBUTION PANEL TO (E) 400A PANEL IN BASEMENT 3. INSTALL UNDERGROUND LINES CONNECTING THE (N) MAIN SWITCHBOARD TO THE (N) DISTRIBUTION PANEL SHEET LIST A.1 COVER SHEET A.2 SITE PLAN A.3 UTILITY PLAN PROJECT SITE N 1 VICINITY MAP NOT TO SCALE NOTES THIS PROJECT SHALL COMPLY WITH THE 2010 CALIFORNIA BUILDING CODE (C.B.C); 2010 C.M.C.; 2010 C.P.C.; 2010 C.E.C.; S.B.M.C. #5440, #5451 AND ANY ASSOCIATED CODES AS OF JANUARY 1, 2008 SHEET NUMBER DATE A.1 06/11/13
VAL VERDE ESTATE SITE PLAN DESIGNER CHRIS BELANGER RESIDENTIAL DESIGN 1187 COAST VILLAGE ROAD SUITE 1-203 MONTECITO, CA 93108 805 259 4525 Dirt Access Road Pond Nursery D I R T A C C E S S R O A D Dirt Access Road AREA OF WORK Reflecting Pool Main House Reflecting Pool Pool PROPERTY LINE Garage Rose Garden Driveway Cottage Cottage Sycamore Canyon Road N 1 SITE PLAN SCALE: 1/64" = 1'-0" SHEET NUMBER DATE A.2 06/11/13
DESIGNER TRENCHING NOTES: Fountain Pond (N) TRANSFORMER 1. LANDSCAPED AREAS: (E) SCE UTILITY POLE NOTE CLEARANCES: 3 FT ON BACK & SIDES AND 8 FT IN FRONT TRENCHING THROUGH LANDSCAPED AREAS WILL BE 6" WIDE AND 40" DEEP. THE PATH WILL BE SELECTED TO MINIMIZE IMPACT ON EXISTING PLANTINGS. PLANTINGS (N) MAIN SWITCHBOARD 800A 120v/208v 3Ø 4W & PULL BOX OAK WILL BE REMOVED ONLY AS REQUIRED AND RE-PLANTED IN UNKNOWN TREE PLACE. SHOULD REPLACEMENT PLANTINGS BE REQUIRED 1187 COAST VILLAGE ROAD SUITE 1-203 MONTECITO, CA 93108 FOR ANY REASON, THEY WILL MATCH THE TYPE AND SIZE OF THE REMOVED PLANT. (N) PITTOSPORUM OAK 805 259 4525 OAK OAK OAK UNKNOWN TREE CANOPY OUTLINE CHRIS BELANGER RESIDENTIAL DESIGN (N) CONCRETE POSTS Road s s e cc Dirt A (N) UNDERGROUND LINES 2. WALKWAYS: EXISTING WALKWAYS ARE COMPOSED OF BRICK OVER SAND WITHOUT GROUT. WHERE THE LINE RUNS BELOW EXISTING WALKWAYS, 24" X 24" SECTIONS WILL BE REMOVED EVERY 10' TO ALLOW TUNNELING BETWEEN. OAK OAK BRICKS WILL BE RE-INSTALLED AFTER INSTALLATION OF THE NEW ELECTRICAL LINES. PROPERTY LINE (E) 400A PANEL (N) 600A DISTRIBUTION PANEL (E) TRANSFORMER TO BE REMOVED FROM SCE Reflecting Pool Main House Reflecting Pool UTILITY PLAN VAL VERDE ESTATE Reflecting Pool N 1 UTILITY PLAN SCALE: 1/16" = 1'-0" SHEET NUMBER A.3 DATE 06/11/13