Modbus RTU RS485 Manual

Similar documents
Operations Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17

DAP III Zone Master User s Guide

For Raychem ACS-30 Controls Systems

Metasys Integrator TITUS Application

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

Modbus Point Map. for the. Data Aire DAP-II

THE OPERATOR ACCESSING YOUR SYSTEM 3 FUNCTIONS OF THE "OPERATOR" 4 PROGRAMMING/CHANGING ACCESS CODES 13 ACTIVATING EMERGENCY ALARMS 14

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Systemair UAB Linų st. 101, LT Ukmergė, LITHUANIA Phone: Fax:

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

RS485 MODBUS Module 8AI

Manual for the integration in BMS/GTC

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

Multistack Modbus Driver: Standard Unit

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

SCIENTIFIC WARMING CABINET Installation, Operation and Maintenance Instructions

MicroTech Series-200 Flooded Screw Chiller

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

ECL Comfort 210 / 296 / 310

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

READ AND SAVE THESE INSTRUCTIONS

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS

OPERATING MANUAL. Need Help? This manual covers: T955WH Wireless Thermostat System. Table of Contents

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

Metasys Integrator Cleaver-Brooks Application

Control Panel Type ABS CP 116/216 COMLI/Modbus - Version 1.25

T855S. Caution. Page. Table of Contents Table of Contents Thermostat Operation Thermostat Quick Reference Programming Features Warranty Information

SECURITY SYSTEM NOTES

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

ComfortSense 7500 Thermostat. User Guide

CLEVER CONTROL Version: V3

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

BLAUAIR AUTOMATIC CONTROL SYSTEM

FlameGard 5 UV/IR HART

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later

F Technical Bulletin SC 370 SMART Modbus Interface

NETWORX TM. User manual NX-4

ETN-24-SUPER-PROG (US Program - Celsius)

Modbus TCP/IP Version 4.0 and Modbus RTU Gateway Version 2.4

XC1008D -XC1011D- XC1015D and VGC810

ComfortSense 7500 Commercial Thermostat. User Guide

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

Elegance. SMT-700 User manual. Ver

Please read this manual carefully before installation and use.

MO n : 12JMC rév A

NetworX NX-8V2. LED Keypad User Manual

Carbon Monoxide Transmitter

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

OPERATING MANUAL. This manual covers TopTech models: TT-S-855 and T855

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

REMOTE CONTROL FOR CHILLER MYCHILLER

NetworX Series NX-1500E LED Keypad

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

Tender Document. MR 193/ Design, Supply & Commission New Control Panel for Ruston 16RK270 Generator

Control manual. Series. Gas-fired direct vent Cast iron boilers. Control adjustment and Operation instructions

Installer Manual KNX Touchscreen Thermostat

User Manual. PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) Fax +44. (0)

User Manual Ichill 200 L/D (Firmware version 1.7)

FlameGard 5 MSIR HART

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

Owner s Manual. Part Number 33CS250-01

Installation and Maintenance Manual IM

T600MEP-2 Programmable Economizer Thermostat

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Owner s Manual. Part Number 33CS250-RC

BURGLAR ALARM PANEL BS-468

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

Version 1.03 January-2002 USER S MANUAL

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

M1000 Alarm Annunciator

CTT8 TEMPERATURE MONITOR DEVICE

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER

User Manual for the. ACCS-1 Digital 7 Day Programmable Thermostat with Zone Control

OPERATING MANUAL. Need Help? This manual covers the following models: T805. Table of Contents

SAT-3 Room Temperature Controller

DC 60 & DM 60 displays

FieldServer Driver - Serial FS Notifier NCA

INSTALLATION AND OPERATION MANUAL

DTSX200 Communications(Modbus) Guide

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

OWNER S OPERATION MANUAL

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

OWNER S MANUAL. Part Number P RF

CONTROL UNIT: REFERENCE MANUAL

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

OWNER S MANUAL. Part Number P

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

TE809-Ats Instructions Manual

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

Transcription:

Modbus RTU RS485 Manual AUTOMATED FUEL MAINTENANCE SYSTEMS FTI-5A, FTI-10A, FTI-20A FUEL TECHNOLOGIES INTERNATIONAL 06/10/2014 Rev B - Fuel Technologies - Modbus

The Modbus Communications Setup Button is Located On the FTI Control Panel Touch Screen To Access: Push the Menu Screen Button Located on the Main Screen Then the Modbus Communications Setup Button Then enter your settings here 2

MODBUS SETUP: The PLC system utilizes a Siemens S7-1214C PLC with a CB1241 RS485 Module. MODBUS communications are a remote MODBUS master system and utilizes MODBUS RTU RS485 communications. The default set up communications protocol is as follows: PLC MODBUS ADDRESS: 1 BAUD RATE: 9600 WORD LENGTH: 8 Parity: NONE STOP BITS: 2 To make a change to any of the Modbus Protocol settings, press the required value on the screen. Where appropriate, a selection will appear. Select the desired value and when ready press the SAVE & INITIALIZE PORT button. This will send the revised values to the PLC. Depending upon the function of individual variables within the PLC each may have a Modbus READ address, a Modbus WRITE address or both. In simple terms, the Modbus mapping was designed to provide the user with a means to reflect the functionality of the touch screen display. 3

Below are the READ and WRITE tables for each of the available variables within the PLC: TAG DESCRIPTIONS MODBUS READ MODBUS WRITE Tag Modbus Tag Modbus Address Value Range / Address Description Auto mode Tank 1 Running MBR_T1_Auto_On 40001.8 Auto mode Tank 2 Running MBR_T2_Auto_On 40001.9 Auto mode Tank 3 Running MBR_T3_Auto_On 40001.10 Auto mode Tank 4 Running MBR_T4_Auto_On 40001.11 Auto Pressure Relief is running MBR_P_Relief_On 40001.12 Sets system in auto mode / Idle & Run MBR_Auto_On 40001.13 MBW_Auto_On 40028.8 Turns system on & off manually MBR_Manual_On_Off 40001.14 MBW_Manual_On_Off 40028.10 Read-Fault Active / Write-Reset Alarm MBR_Fault_Active 40001.15 MBW_Reset 40028.9 Increase tank # to run (1-4) MBW_Inc_Man 40028.11 Decrease tank # to run (1-4) MBW_Dec_Man 40028.12 Low Flow-Loss of Prime Alarm MBR_Low_Flow 40001.0 High Vacuum / Strainer Alarm MBR_Mesh_100_Flt 40001.1 1 Micron Filter / Separator Alarm MBR_Filter_1_Flt 40001.2 10 Micron Filter Alarm MBR_Filter_10_Flt 40001.3 3 Micron Filter Alarm MBR_Filter_3_Flt 40001.4 System High Pressure Alarm MBR_HP_Fault 40001.5 High Water in Separator Alarm MBR_Hi_Wat_Lev_Flt 40001.6 Leak Alarm MBR_Leak_Flt 40001.7 Motor Overload Alarm MBR_OL_Flt 40002.8 Tank # to run on Sunday MBR_Sun_Tank 40003 MBW_Sun_Tank 40029 1-4 Tank # to run on Monday MBR_Mon_Tank 40004 MBW_Mon_Tank 40030 1-4 Tank # to run on Tuesday MBR_Tue_Tank 40005 MBW_Tue_Tank 40031 1-4 Tank # to run on Wednesday MBR_Wed_Tank 40006 MBW_Wed_Tank 40032 1-4 Tank # to run on Thursday MBR_Thur_Tank 40007 MBW_Thur_Tank 40033 1-4 Tank # to run on Friday MBR_Fri_Tank 40008 MBW_Fri_Tank 40034 1-4 Tank # to run on Saturday MBR_Sat_Tank 40009 MBW_Sat_Tank 40035 1-4 Sets number of tanks in system MBR_Tanks 40010 MBW_Tanks 40036 1-4 Sets Low Flow minutes (1-5 minutes) MBR_Lo_Flow_Lmt 40011 MBW_Lo_Flow_Lmt 40037 1-5 Hours (1-23) MBR_Hour 40012 MBW_HOUR 40039 1-23 Minutes (1-59) MBR_Min 40013 MBW_MINUTE 40038 1-59 Day (1-31) MBR_DAY 40014 MBW_DAY 40040 1-31 Month (1-12) MBR_MONTH 40015 MBW_MONTH 40041 1-12 Year (xxxx) MBR_YEAR 40016 MBW_YEAR 40042 Delays the Alarms from Going Off MBR_FltDelay 40017 MBW_FltDelay 40043 1-90 Sec Delays the Pump from Starting MBR_PumpDly 40018 MBW_PumpDly 40044 1-90 Sec Pressure Relief duration MBR_P_Relief_Dur 40019 MBW_P_Relief_Dur 40045 5-90 Sec Tank 1 Run Time Hours MBR_T1_Hours 40020 MBW_T1_Hours 40046 1-23 Tank 2 Run Time Hours MBR_T2_Hours 40021 MBW_T2_Hours 40047 1-23 Tank 3 Run Time Hours MBR_T3_Hours 40022 MBW_T3_Hours 40048 1-23 Tank 4 Run Time Hours MBR_T4_Hours 40023 MBW_T4_Hours 40049 1-23 Sunday Start Time Hours MBR_SunStart_Hr 40024 MBW_SunStart_Hr 40050 1-23 Monday-Friday Start Time Hours MBR_MonStart_Hr 40025 MBW_MonStart_Hr 40051 1-23 Saturday Start Time Hours MBR_SatStart_Hr 40026 MBW_SatStart_Hr 40052 1-23 4

SET FILTERING START TIMES TAG DESCRIPTIONS MODBUS READ MODBUS WRITE Sunday Start Time MBR_SunStart_Hr 40024 MBW_SunStart_Hr 40050 Monday-Friday Start Time MBR_MonStart_Hr 40025 MBW_MonStart_Hr 40051 Saturday start time MBR_SatStart_Hr 40026 MBW_SatStart_Hr 40052 SET RUN TIME HOURS (FILTERING DURATION) TAG DESCRIPTIONS MODBUS READ MODBUS WRITE Tank 1 Run Time Hours MBR_T1_Hours 40020 MBW_T1_Hours 40046 Tank 2 Run Time Hours MBR_T2_Hours 40021 MBW_T2_Hours 40047 Tank 3 Run Time Hours MBR_T3_Hours 40022 MBW_T3_Hours 40048 Tank 4 Run Time Hours MBR_T4_Hours 40023 MBW_T4_Hours 40049 AUTO START FLAG Tag Modbus Address Tag Modbus Address Sets system in auto run mode MBR_Auto_On 40001.13 MBW_Auto_On 40028.8 Value Range The system is put into AUTO mode by writing to address 40028.8 Confirmation of the AUTO status can be read from 40001.13 ACTIVE FAULT AND ALARM RESET FLAG Tag Modbus Address Tag Modbus Address Value Range (Read) Fault active (Write) Fault Reset MBR_Fault_Active 40001.15 MBW_Reset 40028.9 0-1 When a fault / alarm occurs in the PLC this be can remotely reset by writing to Modbus address 40028.9 All faults will be reported by the Fault / Alarm Active Flag (Modbus address 40001.15). MANUAL ON/OFF FLAG Tag Modbus Address Tag Modbus Address Value Range Turn on Manually MBR_Manual_On_Off 40001.14 MBW_Manual_On_Off 40028.10 To start and stop the pump in MANUAL mode (usually used for testing), write to the MANUAL ON/OFF flag (Modbus address 40028.10) and this will turn on the Pump. To stop the manual operation repeat the write to Modbus address (40028.10) this will toggle the functionality of the output. 5

INDIVIDUAL ALARMS ACTIVE FLAG Tag descriptions MODBUS READ MODBUS WRITE Tag Modbus Address Tag Modbus Address Value Range Low Flow-Loss of Prime Alarm MBR_Lo_Flow 40001.0 High Vacuum / Strainer Alarm MBR_Mesh_100_Flt 40001.1 1 Micron/Separator Filter Alarm MBR_Filter_1_Flt 40001.2 10 Micron Filter Alarm MBR_Filter_10_Flt 40001.3 3 Micron Filter Alarm MBR_Filter_3_Flt 40001.4 System High Pressure Alarm MBR_HP_Flt 40001.5 High Water in Separator Alarm MBR_Hi_Wat_Lev_Flt 40001.6 Leak Alarm MBR_Leak_Flt 40001.7 Motor Overload Alarm MBR_OL_Flt 40001.8 Individual Fault / Alarms conditions can be monitored by reading Modbus addresses 40001.0 through 40001.8 DELAY SETTINGS Fault Delay: (delays the alarms from going off) Pump Delay: Delays the pump from starting Pressure Relief Duration: Pressure Relief Duration Setting Tag Modbus Address Tag Modbus Address MBR_FltDly 40017 MBW_FltDly 40043 MBR_PumpDly 40018 MBW_PumpDly 40044 MBR_P_Relief_DUR 40019 MBW_P_Relief_DUR 40045 Value Range 1-90 Seconds 1.90 Seconds 5-90 Seconds The above table indicates the READ and WRITE addresses for the alarm delay settings for the system. Note: A time value for seconds of 10 represents an actual time of 10.0 seconds. 6

PLC CLOCK ADJUSTMENT VALUES Tag Modbus Address Tag Modbus Address Value Range Reads / Writes Hours MBR_Hour 40012 MBR_Hour 40039 1-23 Reads / Writes Minutes MBR_Min 40013 MBR_Min 40038 1-59 Reads / Writes the Day MBR_Day 40014 MBR_Day 40040 1.31 Reads / Writes Month MBR_Month 40015 MBR_Month 40041 1-12 Reads / Writes Year MBR_Year 40016 MBR_Year 40042 XXXX You can write values to the HOURS, MINUTES, DAY, MONTH and YEAR tags in the PLC directly by writing to Modbus addresses 40038-40042. Note Valid write values for are as follows: HOURS: 1-23 MINUTES: 1-59 Day: 1-31 Month: 1-12 Year: xxxx You can also READ the current clock values from the PLC by reading Modbus addresses 40012 through 40016 (for MINUTE, HOUR, WEEK DAY, MONTH AND YEAR respectively). 7

8