Toll Free: Tel: Fax:

Similar documents
SA-3841 User Manuel. 1U 4 Fans Unit with Thermostat Sensor. Version 1.1 Copyright All Rights Reserved

WH7016E Thermostat Product Manual

2 Wire Nuts (or other approved wire connectors) (Field-supplied) Push Button(s) Phillips Head Screwdriver (Field-supplied) Control-R Module

Connect the power supply and equipment to supply to the controller is displayed for the

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

TOP AND CONSOLE PARTS For Models: LGQ9858PW0, LGQ9858PG0 (White/Grey) (Biscuit/Gold)

Heating Zone Control. How to apply RESOL MX controller

Wireless High Voltage Digital Thermostat

INSTALLATION & USER MANUAL

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

SCHMIDT LED Measured Value Display MD Instructions for Use

Electronic Pellet Burner Controller NPBC-V3-1

ST Wiring diagram. Product description. Four-stage controller. Order number

Carbon Rack Enclosure

United Kingdom. Smart Thermostat 230 V Relay Installations. Guide for Professional Installers

aura-t TP536/GBR ventilation systems

aura-t TP536/EU ventilation systems

Plug-n-Play Humidity Controller. IHC-200 User Manual. Version 1.3s. Inkbird Tech. Co., Ltd.

Electronic Pellet Burner Controller NPBC-V3M

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat

Model: Available in : Sapphire Black and Glacier White. 1 Series

27" GAS DRYER MODELS: 7MWGD87HEDC0 (Chrome Shadow) 08/19/ Whirlpool Corporation Part No. W Rev. A

Multi Boiler Guide. Kit #

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Cm Pelet-set (60-90 kw)

User Guide. Stainless Steel Filter Housing Heater

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

ST Wiring diagram. Product description. Standard temperature controller. Order number

WILLHI WH1436H Digital Humidity Controller Manual (NEW VERSION)

Electronic Controls Handbook Programming Flow Charts & Parameter Lists for

GreenCon On/Off Room Thermostat

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Easy-Stat. Wireless Programmable Room Thermostat Pt No

GreenCon On/Off Room Thermostat

Operating Instructions Model : HC HC-N

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS. EN-RaychemGreenLeaf-IM-EU0209 THERMAL BUILDING SOLUTIONS

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

Model: Available in: Sapphire Black and Glacier White. 1 Series

W6636 East Avenue North, Onalaska, WI USA (608) Fax: (608)

OPERATION MANUAL RK-2001W2 SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER. Version 9A15

Operating instructions Page 16. Refrigerator Read the operating instructions before switching on for the first time

ECL Comfort V a.c. and 24 V a.c.

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

INSTALLATION and OPERATION INSTRUCTIONS

Horizon Elite Ice Machine Models with RIDE Technology Installation Instructions for Vision

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

SERVICE MANUAL REFRIGERATED AIR DRYER DIGI-PRO CONTROLLER WARRANTY NOTICE

CME650 SERVICE PARTS

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

HSD Dry Cabinet

EW 40 Wireless Fan Control

4 in 1 Digital Thermostat Control

Chevrolet Corvette Auxiliary Electric Condenser Fan Kit with Trinary Switch ( CCA)

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

BMW Parts and Accessories Installation Instructions

Programmable Outlet Thermostat. User Manual. Version 1.5s. Inkbird Tech. Co., Ltd.

SERVICE DATA SHEET (9704) Rev. D

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

D400A/W Ice Machine. Installation Manual. D400A ice machine. D400W ice machine. Order parts online.

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

EFET 535. Installation Manual INT INT

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

Digital Thermostat Models: VS30W and VS30B

30-INCH SLIDE-IN ELECTRIC RANGE. Model No. CPES3085K L95S1

ORION Mini-Rep INSTALLATION MANUAL

Startup Checklist. check off executed action! Altherma EHS(X/H) Daikin Altherma EHSX Altherma EHSXB Altherma EHSH Altherma EHSHB -08P50AA -16P50AA

Digital Marine Exhaust Temperature Alarm

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Service Instructions

P R O D U C T C A T A L O G U E

27" GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/ Whirlpool Corporation Part No. W Rev.

Installation Instructions

ECL Comfort V a.c. and 24 V a.c.

40-INCH FREE- STANDING ELECTRIC RANGE LE. Model No. FEF450B D2015

DOOR AND PANEL PARTS For Models: DU1300XTVB0, DU1300XTVQ0, DU1300XTVT0, DU1300XTVS0 (Black) (White) (Biscuit) (Stainless)

GAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/ Maytag Part No. W Rev. A

Model No: 56DFH-L HS-1289-C. Cover for non-light option

Model 5190-F Temperature/Humidity Probe

Battery Powered Electronic Room Thermostat Cat. No. TRT033

UNDERCOUNTER DISHWASHER MODELS: MDB8959SFE2 (Black) MDB8959SFH2 (White) MDB8959SFZ2 (Stainless) 07/13/ Maytag Part No. W Rev.

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A

Model 5190-E Temperature/Humidity Probe

PARTS BOOK. From S/N:

Refrigerated air dryers

OVEN PARTS For Models:KEMS308SBL05, KEMS308SWH05, KEMS308SSS05 (Black) (White) (Stainless)

Monitoring Software for NPBC-V3M-1 User Manual

Oil Streak Streak Sensing Unit

GAS DRYER MODELS: WGD8000DW0 (White) 03/30/ Whirlpool Corporation Part No. W Rev. C

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40)

DryAire DRYING CABINET

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

OG5000 Ozone Generator Model OG5000B-A. User Manual

Transcription:

Toll Free: 1-888-865-6888 Tel: 510-226-8368 Fax: 510-226-8968 Email: sales@rackmountmart.com Copyright 2015 Synergy Global Technology Inc. All rights reserved.

RA4007 User Manuel 1U 4 Fans Unit with Thermostat Sensor Version 1.1

Contents 1. Introduction 1. Overview 2. Specification 3. What's In The Box 2. Installation 1. Installing the Thermal Sensor 2. Installing on a Rack 3. System Interface 1. Thermostat Display 2. Controlling the Thermostat 3. Feature Descriptions 4. Parameters

Introduction Overview This fan unit includes a power switch and a LED thermostat monitor on the front. This fan unit includes a power connector and a connector for a thermal sensor. Specification Rack Size Fans 1U 4 x 120 mm AC Fans Dimension (W x D x H) 19 x 17.75 x 1.75 Weight 15 LBS

What's In the Box The package for RA4007 includes the following items: 1 x 1U Fan Unit 1 x Thermal Sensor 1 x Power Cord 8 x Pairs of M6 Nuts and Screws Installation Installing the Thermal Sensor To install the thermal sensor, press down on black tab on the back of the fan unit. Put one end of thermal sensor inside the square sized hole above the black tab. Release the tab after the end is inside the hole. Next, press down the red tab on the back of the fan unit. Put the other end of the thermal sensor inside the square sized hole above the red tab. Release the tab once the end is inside the hole. Finally put the thermal sensor in the place on the rack that is most important to keep cool. Installing on a Rack To install the fan unit on a rack, move the rear mounting bracket to the desired position that will fit the rack. Put the M6 cage nuts into the desired position on the rack. Put the fan unit in the desired position. Finally screw in the M6 screws with washer into the M6 cage nuts.

Thermostat Display System Interface The LED display normally displays the current temperature as detected by the thermal sensor. Controlling the Thermostat Temperature Control: Press the set button gently to display the controlling temperature. The controlling temperature is the temperature that will determine whether the fans turn on or off. If the current temperature is higher than the controlling temperature, the fans will turn on until the current temperature drops to the controlling temperature. To change the controlling temperature, press the set button to display the controlling temperature. Then, press up or down arrows to increase or decrease the controlling temperature. Data Settings: Press the set button for 6 seconds to enter the settings. Upon entering settings, HC will be displayed. Use the up and down arrows to set HC-LS-HS-Pt-CA-d. down. Choose HC, H represents warm mode, C represents cold mode. down. Choose lowest temperature limits: -45ºC to temperature control- 1ºC. down. Set delayed start timer from 0 to 5 minutes. down. Choose temperature correction: -15ºC to 15ºC.

down. Choose highest temperature limits: Temperature control+1ºc to 80ºC. down. Choose return difference: 1ºC to 15ºC. ERROR Symbol: When the thermal sensor is opened or short circuited, Code E1 will be displayed. Feature Descriptions Cooling: When the current temperature is greater or equal to setting temperature + temperature hysteresis and the delay time has passed, the load relay is ON. Cooling Stop: When the current temperature is less than or equal to the controlling temperature, the load relay is OFF. Heating System: When the current temperature is less than or equal to the controlling temperature-the temperature hysteresis and the delay time has passed, the load relay is OFF. Heating System Stop: When the current temperature is greater or equal to the controlling temperature, the load relay is OFF. Tips: Cooling and heating conversions are set in the parameter HC menu selection; H is heating system, C is cooling. Parameters Code Function Setting Range Factory Value Unit HC Cooling/Warming H/C C --------- LS HS Alarm on Low Temperature Limit Alarm on High Temperature Limit -45 to Temperature Control-1 Temperature Control+1 to 80-45 ºC 30 ºC Pt Delay Time 0-5 1 Minute CA Temperature Correction -15ºC-15ºC 0 ºC d Temperature Return Difference 1-15 2 ºC Copyright 2015 Synergy Global Technology Inc. All rights reserved.