ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems

Similar documents
Heat Pumps and Public Swimming Pools, a Perfect Match

What is the Problem? Enemy Number 1 Biofilms/Bioslim. Two Common Enemies We Fight

SowBridge. Basic Environmental Factors & Their Effects on Pigs. Importance of Ventilation for Pig Comfort

Dehumidification: Energy Efficiency Comparisons

Mr. GoodTower Service Center

Section 2. Product overview & label familiarisation

Akiki Engineering Est.

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

SOUTHEND CARELINE ANNUAL REPORT

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Cable Dehumidification Systems for Suspension Bridges. Daniel Faust, P.E. AECOM, Inc.

On Balance: Heat Rejection Control a Packaged Solution

Enhance Facility Energy Management at Naval Expeditionary Base Camp Lemonnier, Djibouti. 12 May 2011

CHART PERUVIAN TECHNICAL STANDARDS

A PRACTICAL GUIDE TO KUUL VITALITY EVAPORATIVE MEDIA MAINTENANCE AND SERVICE

Free cooling on RTAF Chiller. Integrated option

Electronic Air Cleaner Model Number CSC1000 OWNER S MANUAL. Installation Operation Basic Service Guide Technical Repair Guide Repair Parts

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

QUALITY. Task Force. Shifting from Corn Drying to Corn Storage. Dirk E. Maier, Agricultural Engineering. Average Temperature F

Water Efficiency. Industry Specific Processes. Metal Finishing. for Commercial, Industrial and Institutional Facilities

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

Evaporative Cooling products

WLAC Facilities Committee Meeting. September 18, 2017

Protective Chemistry for Steam Boiler Wet Layup posted to DPS client area on:

Thermal equalization is the obvious answer to the situation. But, how is "thermal equalization" achieved?

Technical Document Condensing hot water boilers

Make gelato and more delicious things right in front of your customers Let the show begin!

TREATMENT AND CONDITIONING OF DISMANTLED MATERIAL AND OPERATION WASTE IN EWN OVERVIEW. Rohde, Mathias

Cork County Energy Agency

A PRACTICAL GUIDE TO KUUL CONTROL EVAPORATIVE MEDIA MAINTENANCE AND SERVICE

Boulder County Comprehensive Drilling Plan Surface Owner Meeting. Thursday, Oct. 19, 2017

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Sterilex Ultra Disinfectant Cleaner & Activator Solution Usage Guidelines

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

2010 Fire Log Fire Log. Annual Fire Safety Report

PATENTED APG OZONE CELLS DESTROYS HARMFUL CONTAMINANTS REDUCE CHEMICAL DEMAND

Heat recovery systems. For hot air and hot water applications.

The Ed Roberts Campus Berkeley, CA

Descaler & Prevention

Akiki Engineering Est.

Strategies for Summer Utility Savings. Residential Environmental Program Series May 15, 2013

EcoMaster - Residential Pools up to 40,000 Gallons

Case Study and 700 HP Steam Boilers - Scale

Cooling Options for Geothermal and Concentrating Solar Power Plants

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

EcoCooler Legionella Risk Assessment Information Pack

Laboratory Fume Cupboards

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

R4 Ventures LLC White Paper

WLAC Facilities Committee Meeting. May 15, 2017

Institutional Laundry & Warewash Solutions

Chiller Tube Cleaner Buying Guide

Heritage Park Irrigation System Inspection Review of Water Use Estimated Water Budget Potential for Savings

Water Wise at Home. Coachella Valley Water District (760)

The complete approach to the care and management of A/C & refrigeration systems

The quest for acid-tolerant lucerne

Water Wise at Home. A guide to finding leaks, conserving water and making every drop count in your home

Asparagus Response to Water and Nitrogen

Time-Based Scheduling of Residential Ventilation

Microirrigation of Young Blueberries in Florida 1

ZEROwaste HX PERC SYSTEM USER MANUAL. AIR QUALITY LABORATORIES Seattle, Washington

chlorination evolved FEEDERS New Design HIgh Efficiency Made in the U.S.A.

Roof Runoff Harvesting Benefits for Regional Conditions in Low Density and Medium Density Residential Areas. Leila Talebi 1 and Robert Pitt 2

Special Topics on Residential HVAC

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

GORD COOKE. issues associated with humidification and dehumidification systems. In this article, humidification

Ice Machine Preventative Maintenance

Innovative Cleaning Technology

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

Installation, Operation and Maintenance Manual

CROWN YEARLY PROPERTY SCHEDULE

FOOD AREA SOLUTIONS Cleaning Spray & Wipe Disinfectant Skin Care Vegetable Cleaning Beerline Cleaning Sanitisers

Phalaenopsis. Pot size used:

ToThePOINT. Best Practices. Best Practice No. 1: Have your boiler inspected regularly by an authorized inspection agency. LOSS CONTROL SERVICES

Data driven insights from the nation s deepest ever customer energy research

Backpack CoilPro TM Coil Cleaner

August 11, Enviro Tech Chemical Services, Inc. Joseph Donabed B.S.

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81)

LEASEHOLD YEARLY PROPERTY SCHEDULE

Practical and Effective Approaches to Residential Ventilation for Production Builders

Procedures in University Laboratory. August 25, 2010 ULAR Continuing Education & Professional Development Class

Auburn University Basketball Arena:

Boulder County Comprehensive Drilling Plan Surface Owner Meeting. Thursday, Nov. 2, 2017

Industrial Descale Solutions & Descale Services

EcoMaster - Residential Pools up to 40,000 Gallons

How about Savings in Time, Money, Energy and Longer Life?

AGC Sputter Coating Glass Processing Guidelines

Novel Press Fabric Cleaning Method Increases Productivity in a Sustainable Manner

MASTER PLAN KICK-OFF Open House #1A, April 28, 2015

Australian Indoor Flue Installation Instructions Vertical Termination Flue Kits for Universal H-Series (Forced-Draft) Heaters

PTC Creo 2.0 Hardware Support Hewlett Packard

Trials of Vexo inhibitor in domestic central. heating systems

Ozone Generator Systems

Energy Efficient Cooling Solutions

HG-1500 Ozone Generator

Step-by-Step Guide To Clean Your Own Pool

ENERGY MANAGEMENT IN MILK POWDER PLANTS

Transcription:

Case Study ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems Steve Chewning, CWT, James Hall, Southeastern Laboratories, Inc. August 2017 Air washer systems used in the tobacco industry to filter and condition air in the plant present difficult and unique challenges to the water treatment professional. While air washers are utilized in a number of different manufacturing operations, they are most often associated with the textile and tobacco industry. This is a function of the air washer s ability to control temperature, humidity, and clean plant air. The typical air washer system operates by passing air returning from plant production areas though a dry filter media, then through a wall of water. This process captures particulate and gaseous impurities generated within the manufacturing process. Fine water droplets and excess atmospheric humidity are captured and removed from the airflow within a series of eliminator blades as the air exits the washer water spray area. This conditioned air is returned to the plant production areas via a series of fans and ducts. The tobacco industry has relied on open washers for many years. Organic impurities removed and captured within the system water, water loss resulting from plant dehumidification, and the mineral accumulation during periods of plant humidification present unique challenges for the water treater. PH control is often required to neutralize acidic compounds generated within the tobacco washer, while elevated nitrogen levels accelerate bacterial activity. Various flavoring compounds and packaging materials introduced into the water also enhance bacterial growth. The bio-slime masses associated with this bacterial activity can result in poor heat transfer within the chilled water system, clogged spray nozzles, frequent system

cleaning, accelerated metal corrosion, and even plant odor. The production of tobacco products requires proper plant temperature and humidity control within an odor free environment. The water treatment industry relied primarily on non-oxidizing biocides applied in conjunction with organic dispersants during the early years of plant air conditioning. This was in response to the tobacco industry s concern that the use of oxidizers could impact the taste and fragrance of their products. Frequent air washer cleaning was often required with these programs. Newer stabilized bromine based compounds are now often used within these systems in conjunction with several non-oxidizing compounds, yielding improved bacterial control. Some operations, however, have experienced surface corrosion on equipment within the production areas of the plant; a result of feeding these oxidizing materials. Bromine-chlorine odors can also be an issue with plant personnel. Feed of organic dispersants, corrosion inhibitors, and alkaline ph control products is also required. A Southeastern US cigarette manufacturing operation had experienced many of the previous outlined issues regarding the water treatment programs employed within the plant s open air washer systems. The plant decided to conduct a trial evaluating ProMoss TM, an all-natural water treatment program that utilizes a specific species of Sphagnum Moss common to New Zealand and northern Minnesota. This novel treatment approach is relatively new to the industrial water treatment market having been introduced about three years prior in the US. ProMoss TM has been used in the pool and spa industry for over a decade. One of the more heavily stressed air washer systems was chosen for the trial. The feed of all traditional chemical treatment compounds was discontinued on the subject washer and eight 150 gram ProMoss TM packets were submerged in the air washer sump. The dosage of ProMoss TM was calculated to last 30 days. A small amount of hydrogen peroxide was also applied, maintaining 0.5-2.0 ppm of free halogen residual. The air washer units in this plant operate as individual systems and are cooled via individual plate and frame heat exchangers. The impact of the ProMoss TM material was evident within one week of the application. A slight foam developed along with a thin layer of a gelatinous polysaccharide material associated with bacterial slime masses on top of the sump water. Small chunks of organic material and dead bacteria were noted on the washer screens and within the ph/bleed controller piping. The traditional chemical treatment program had previously utilized an automated ph controller and metering pump to apply a liquid alkaline compound, maintaining the bulk cooling water ph between 7.8-8.0. This was discontinued after the addition of ProMoss TM. The ph immediately dropped to the 7.0-7.3 range and stabilized at those levels (Figure 1). Normally, the tobacco particulates would have depressed the ph to below 5.5 without traditional chemical addition. 2

Adenosine Triphosphate (ATP) and total bacteria counts increased dramatically as a result of the breakdown and release of organic material and sessile growth adhering to the system s wetted surfaces into the bulk water (Figure 2). Several strains of pseudomonas bacteria growing within the wetted areas above the waterline began to disappear. 8.5 ph Readings-Production AW #2 ProMoss TM Treated 8.0 7.5 7.0 PH 6.5 6.0 5.5 ProMoss TM Applied 5.0 4.5 4.0 Jun-16 Jul-16 Aug-16 Sep-16 Oct-16 Nov-16 Dec-16 Jan-17 Feb-17 Mar-17 Apr-17 May-17 Jun-17 Figure 1 The initial clean-up period resulted in a bit of pain for the plant HVAC staff. Clogged washer nozzles, frequent screen cleanings, and unscheduled manual cleaning of the plate and frame heat exchanger were the immediate impact of the removal of organic buildup and debris from system surfaces. These issues began to subside within four weeks of application. Assessment of bacterial growth indicated an increase in activity after a two-week exposure period. This was unusual. The typical ProMoss TM application maintains efficacy of bacterial control for a four-week period. The decision was made to increase the monthly dosage to 2400 grams per month within the 7500-gallon trial washer system. This was required due to the highly-fouled nature of the system and the heavy organic loading from the tobacco operation. Results improved dramatically following the second increased ProMoss TM application (Figure 3). 3

Total and Free ATP - Production AW #2 ProMoss TM Treated 2500 2000 ProMoss TM Applied ATP, RLU'S 1500 1000 500 0 Jun-16 Jul-16 Aug-16 Sep-16 Oct-16 Nov-16 Dec-16 Jan-17 Feb-17 Mar-17 Apr-17 May-17 Jun-17 2-ATP-T 2-ATP-F Figure 2 Total Bacteria Counts 1.E+06 1.E+05 1.E+04 1.E+03 1.E+02 Total Bacteria Counts - Production AW #2 ProMoss TM Treated ProMoss TM Applied 1.E+01 Jun-16 Jul-16 Aug-16 Sep-16 Oct-16 Nov-16 Dec-16 Jan-17 Feb-17 Mar-17 Apr-17 May-17 Jun-17 Figure 3 The trial tobacco washer has been treated exclusively utilizing the ProMoss TM material, supplemented with a low base feed of 32% hydrogen peroxide for six months. The application of both compounds has been reduced following the initial clean-up period. Currently, 1800 grams per month of ProMoss and approximately 70 lbs. of hydrogen peroxide are applied on a monthly basis. Results have been very promising. The plant engineering staff has decided to employ the 4

ProMoss TM program throughout the entire HVAC system. This includes five open air washer systems, two evaporative chiller towers, and one evaporative air compressor tower. Cleanup of deposits on wetted surfaces has been nothing short of remarkable, greatly exceeding any prior results obtained with chemical treatment. The following photos show the feeder piping to one of the plate and frame heat exchangers: the first at the start of the ProMoss TM program and the last three months later. ProMoss TM breaks down organics that hold deposits together. Deposits have been removed with over 50% of the piping down to bare metal. Start of ProMoss TM Treatment 3 months later Other wetted surfaces are also significantly cleaner than they were under chemical treatment. Rear Eliminator Blades Before ProMoss TM Rear Eliminator Blades ProMoss TM program 5

Spray Header Piping Before ProMoss TM Spray Header Piping ProMossTM Program Spray Header Piping ProMoss TM Program In summary, the ProMoss program has resulted in the following benefits for the subject manufacturing operation: Improved control of organic contamination Reduced heat exchanger differential pressure, resulting in less frequent cleaning Elimination of plant corrosion Removal of old deposits in the system Elimination of plant odors Reduced system bleed rates Improved washer efficiency resulting from cleaner spray nozzles Reduction of chemical inventory and feed equipment Acid neutralization within the washer cooling water without chemical addition While the use of the ProMoss technology is relatively new within the tobacco industry, the initial results have been very positive. It is proving to be a viable alternative in stressed systems requiring elevated dosages of water treatment compounds or systems that have not responded to traditional chemistry. 6