ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

Similar documents
Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

MICRO CONTROLLER E Z SERIES

MICRO CONTROLLER S Z SERIES

F4 Process Controller Installation and Operation Guide

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

UDC 700 Universal Digital Controllers and Indicator Specifications

PID Temperature Controller. ITC-100 User Manual. Version 2.0s. Inkbird Tech. Co., Ltd.

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Temperature Controllers

GCS-300 No.GCS31E

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

02/11/2015

Temperature Controller

TC515 and TC600 Installation Manual. a Winters company

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Series Temperature Controller Instruction Sheet

02/11/2015

4TEMPERATURE CONTROLLER

Instruction manual for DIN rail mounting type indicating controller DCL-33A

99 Washington Street Melrose, MA Phone Toll Free Visit us at

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

Instruction manual Micro-computer based digital indicating controller

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

VERTEX F4 Instruction Manual

INSTRUCTION MANUAL Micro-computer based digital indicating controller

I/A Series 716C 1/16 DIN Temperature Controller

Bench-Top Vacuum Oven with 28 segments programmable controller

ER65 - Mini Rack Controller Electronic Refrigeration Line

+ A B V B NO NC V COM PV PV

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

TEMPERATURE CONTROL MODULE MODEL R3-TC2

Model 96VTR ¼ DIN Process Controller

Specification , July 2015

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

General Specifications

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

Series Digital Controller Instruction Sheet

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Instruction manual Temperature Controller KT7

Oven Control System Operation - Ver 2.8

UDC100 Universal Digital Controller Specifications

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

TEMPERATURE CONTROLLER

OVEN INDUSTRIES, INC.

DT968C C.T. BATH CONTROLLER

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

4000 1/4 DIN /16 DIN /8 DIN

REFRIGERATED BATH CIRCULATOR. Instruction Manual. Covers model : LRBC-13C / LRBC-22C. Please read this manual carefully before using the instrument

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

DC1000 Series Digital Controller Product Manual August 2005

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

ER52 - Evaporator Controller

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

SR70 (SR ) Series Digital controller Instruction Manual

Table of Contents SECTION PAGE

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See

Universal controller for panel mounting Models CS6S, CS6H, CS6L

INSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL

CONTENTS. Micro-controller X. Instruction Manual. (Socket type) Model : PXR4 Socket INP-TN1PXR4S-E

Plug-n-Play Humidity Controller. IHC-200 User Manual. Version 1.3s. Inkbird Tech. Co., Ltd.

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Pre-Cool and Free- Cool Fan Control

Example of Applications and Parameter Functions

Installer Manual KNX Touchscreen Thermostat

Pioneer-R16 Gas Monitor Operator s Manual

HD220 Dual Output Programmable Humidity Controller

CN4800 Series CONTROLLER

Nov 08 PRODUCT SPECIFICATION SHEET

Altanium Temperature Controllers

MC-5 Series Micro Processor Temperature Controller

Multi-point Digital Controller MA900/MA901. Initial Setting Manual IMR01H03-E4 RKC INSTRUMENT INC.

SD Series Users' Manual

CONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Oakton TEMP 9500 Advanced Multiparameter Controller

Programmable Outlet Thermostat. User Manual. Version 1.5s. Inkbird Tech. Co., Ltd.

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

KC-400 KC-600 KC-700 KC-800 KC-900

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

R1000 / R1040 / R1080

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

Automatic Isokinetic Sampler ST5

CONTENTS. Micro-controller X Model : PXR5/9. Instruction Manual. INP-TN1PXR5/9f-E

INSTALLATION INSTRUCTIONS

108A OTP1800. Grid Support. General Description

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

AUTOMATED PRODUCTION SYSTEMS, INC Pine Road Huntingdon Va l l ey PA P h o n e : (215) FA X : (215)

CEMA CM20 Series Digital Controller Operation Manual CM24 CM22 CM21 CM23 CM25

Transcription:

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual

I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4 (AUX) 1. (Part 1) Model Series AI-208, standard temperature controller, 0.3%FS±1 accuracy. Multiple thermocouples and RTDs are selectable Suitable for application. Maximum support two alarms contact output Universal voltage input (100~240VAC) 2. (Part 2) Front panel dimension Size Front Panel width height Cut Out width height Depth Behind Mounting Surface A 96 96mm 92 92mm 100mm B 160 80mm 152 76mm 100mm D 72 72mm 68 68mm 95mm D2 48 48mm 45 45mm 95mm E 48 96mm 45 92mm 100mm F 96 48mm 92 45mm 100mm

3. (Part 3 and 4) indicate the module installed in OUTP and AUX sockets. Allowed modules in each socket are as below: Allowed Type N L L1 L5 G Module Socket 3. OUTP (main output) 4. AUX (Auxiliary output) N L L1 L5 G (or none) no module installed Relay contact output module (Capacity: 5A/250VAC, normal open) Relay contact output module (Capacity: 2A/250VAC, normal open/ normal close) Dual relay output module Output module (Capacity: 2A/250VAC, normal open, support AU1 and AU2 alarm output) SSR voltage output module (30mA/5VDC) II. TECHNICAL SPECIFICATION 1. Input type : Thermocouple: K, E, J, N Resistance temperature detector: Pt100 2. Instrument Input range : K, E, J, N : (0~+999) ; Pt100: (0~+800) 3. Measurement accuracy : 0.3%FS±1 4. Temperature display resolution : 0 or 0.0 (0.0 just for 0~99.9 display) 5. Control mode: On-off control mode, or PID control with the function of parameter auto tuning. 6. Alarm function: High limit alarm, Lower limit alarm, Deviation High Alarm; providing the function of alarm blocking at the beginning of power on. 7. Power supply voltage rating: 100-240VAC, -15%, +10% / 50-60Hz. 8. Power consumption: 2W 9. Ambient temperature: -10~+60, Humidity: 0~90RH%

III. FRONT PANEL AND OPERATION 1 2 3 4 5 6 7 Process Value(PV), or parameter code Set Value(SV), alarming code, or value of a parameter Setup key, for accessing parameter table, and confirming change. Data shift key, also for activating auto turning Data decrease key Data increase key Status display LED, OP1, AU1, AU2, and RUN indicate I/O operation of the corresponding module. Basal display status: When power on, will shows the process value (PV) and the set point (SV). lf the input signal is out of the measurable range (for example, the thermocouple or RTD circuit is break, or input specification sets wrong). Instrument will alternately display ora, and limit alarm of PV, moreover, instrument will automatically stop the output. IV. OPERATION DESCRIPTION Set Value Setting: In basal display status, if the parameter lock Loc isn't locked, we can set setpoint (SV) by pressing or. Press key to decrease the value, key to increase the value, and key to move to the digit expected to modify. Keep pressing or, the speed of decreasing or inscreasing value get quick. The range of setpoint is between the parameter SPH. The default range is 0 to 400. Parameter Setting: In basal display status, press and hold for about 2 seconds can access Field Parameter Table. Pressing can go to the next parameter; if parameter have not locked, pressing or can modify a parameter. Press and hold can return to the preceding parameter. Press (don't release) and then press key simultaneously can escape from the parameter table. The instrument will escape auomatically from the parameter table if no key is pressed within 30 seconds. Setting Loc=808 and then press can access System Parameter Table. AI artificial intelligence control and auto tuning When AI artificial intelligence control method is chosen (CrL=AI), the PID parameters can be obtained by running auto-tuning. In basal display status, press for 2 seconds, the At parameter will appear. Press to change the value of At from off to on, then press to active the auto-tuning process. During auto tuning, the instrument executes on-off control. After 2-3 times of on-off action, the instrument will obtain the optimal control parameter value. If you want to escape from auto tuning status, press and hold the key for about 2 seconds until the "At" parameter appear again. Change At from on to off, press to confirm, then the auto tuning process will be cancelled. Note 1: If the setpoint is different, the parameters obtained from auto-tuning are possible different. So you d better set setpoint to an often-used value or middle value first, and then start auto-tuning. For the ovens with good heat preservation, the setpoint can be set at the highest applicable temperature. Depending on the system, the auto-tuning time can be from several seconds to several hours. Note 2: Parameter Ctl (on-off differential, control hysteresis) has influence on the accuracy of auto-tuning. Generally, the smaller the value of Ctl, the higher the precision of auto tuning. But Ctl parameter value should be large enough to prevent the instrument from error action around setpoint due to the oscillation of input. Ctl is recommended to be 2.0. Note 3: AI series instrument has the function of self-learning. It is able to learn the process while working. The control effect at the first run after auto tuning is probably not perfect, but excellent control result will be obtained after a period of time because of self-learning.

V. PARAMETER AND SETTING Field parameter table (Press and hold for 2 seconds to access) Yudian (H.K.) Automation Technology Co. Ltd. Code Name Description Setting Range HIA LoA HdA Loc AHY High limit alarm Lower limit alarm Deviation high alarm Parameter lock Hysteresis Alarm on when PV (Process Value) >HIA; alarm off when PV<HIA-AHY Alarm on when PV (Process Value) < LoA; alarm off when PV > LoA+AHY Alarm on when PV-SV>HdA; alarm off when PV-SV<HdA-AHY Loc=0~1: Allowed to modify parameters HIA, LoA, HdA and SV. Loc=2~3: Allowed to modify parameters HIA, LoA, HdA. But cannot change SV. Loc=4~255: NOT allowed to modify any parameters and SV. Loc=808, Set to 808 and press, allowed modify all parameters. Avoid frequent alarm on-off action because of the fluctuation of PV, usually sets to AHY=2 0~255 0~200 Alarm HdA LoA HIA Output to (x100) (x10) (x1) AOP Alarm output assignment None 0 0 0 AU1 1 1 1 0~444 AU2 2 2 2 eg: AOP=201 means HdA have alarm action from AU2, LoA, no alarm action, HIA alarm action output from AU1. CrL Control mode onf : On-off control, When PV=SV, Output stop. When PV<SV-CHY, start output. AI : AI PID control, high precision and the output time proportion can set by parameter Ctl re: Reverse acting. Increase in measured variable causes a decrease in the output, such as heating control. dr: Direct acting. Increase in measured variable causes an increase in Act Acting method the output, such as refrigerating control. reb: Reverse acting with low limit alarm and deviation low alarm re, dr, reb, drb blocking at the beginning of power on. drb: Direct acting with high limit alarm and deviation high alarm blocking at the beginning of power on. P Proportion band Proportion band in PID with unit or 1~999 I Time of integral Time of integral in PID. No integral effect when I=0 0~999 Sec d Ctl CHY Time of derivative Control period Control hysteresis Time of derivative in PID. No derivative effect when d=0 Small value can improve control accuracy. For SSR output, generally 0.5 to 3 seconds. For Relay output, generally 15 to 40 seconds, because small value will cause the frequent On-Off of mechanical switch and shorten its service life. Ctl is recommended to be 1/4 1/10 of derivative time. When control under on-off control, Ctl use as restart delay time after off, for protect compressor application. CHY is used for ON-OFF Control. PV > SV, Output turns OFF; PV<SV-CHY, Output turns ON. 0~999 Sec 0.5-300 SEC 0~200

InP Input specification Sn Input spec. Sn Input spec. 0 K 1-3 Spare 4 E 5 J 6 Spare 7 N 8-20 Spare 21 Pt100 0~21 dpt Resolution 0 or 0.0 selectable, 0.0 just for 0~99.9 / display Scb Input shift Scb is used to make input shift to compensate the error produced by sensor or input signal. PV after compensation= PV before compensation + Scb. -99~+99 FIL PV input filter The value of FIL will determine the ability of filtering noise. When a large value is set, the measurement input is stabilized but the response speed is slow. Generally, it can be set to 1 to 3. If great interference exists, then you can increase parameter FIL gradually to make momentary fluctuation of measured value less than 2 to 5. When the instrument is being metrological verified, FIL s can be set to 0 or 1 to shorten the response time. 0~40 Fru Selection of power frequency and temperature scale 50C: 50Hz, 50F: 50Hz, 60C: 60Hz, 60F: 60Hz, SPH Upper limit of SV Maximum value that SV allowed to be. When SPH=400, the SV range will 0~400 VI. INSTRUMENT INSTALLATION AND WIRING Wiring graph for instruments with dimension A, B, E or F 1 100-240VAC~ 2 3 AU1 Alarm Output 4 N/C AU2 5 COM COM AUX Main Output 6 7 + COM Note: The graph suits for upright instruments with dimension A or E OUTP 8 9 10 + For instruments with dimension B or F size, just clockwise rotate the graph 90 degree.

Wiring graph for D2 dimension(48x48mm)instruments: Yudian (H.K.) Automation Technology Co. Ltd. Wiring graph for D dimension (72mm X 72mm) instruments