Advance Release September 2009

Similar documents
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

technical guide Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units

SKYPAK II, 3 Ton Series, gives you a

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

SKYPAK II, 3 Ton Series, gives you a

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

PACKAGE AIR CONDITIONER

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

MACH N-407 Heat Pump Air-Cooled Chiller

SKYPAK II Heating & Cooling Self Contained Packages

MAC N-407 Air-Cooled Chiller

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

VertiCool Aurora Engineering Guide

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

C13-Series Engineering Guide

PAR5. Product Specifications

PAJ3. Product Specifications

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

VariCool VAV Engineering Guide

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

SECTION AIR HANDLING UNIT

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

High Heat COP. High/Low Stage

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Split System Heat Pumps

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Air-Cooled Condensing Units with Compact Screw Compressors

GUIDE SPECIFICATIONS AQUARIUS ii

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

WCH5**4. Product Specifications

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

TECHNICAL SPECIFICATIONS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

RGE 13 A T - 1 A

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

4YCC3048A3096A /3/ /

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Model CPH Horizontal Water-Cooled Air Conditioning Unit

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

50TM TFF COMBINATION HEATING/COOLING UNITS

Concealed Ducted Split Series R-407C MBH

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

COMMERCIAL AIR HANDLER

50TM COMBINATION HEATING/COOLING UNITS

13 SEER PACKAGE GAS / ELECTRIC UNIT (575V -3 Ph -60Hz) 36 to 61 MBtuh

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

CoolSpot Engineering Guide

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

AIR COOLED PACKAGED CHILLER

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Modular Supply Make-Up Air Unit

COMMERCIAL AIR HANDLER

MODEL DPH, CEILING MOUNTED, HORIZONTAL DUCTED AIR CONDITIONING UNITS INSTALLATION & OPERATION INSTRUCTIONS

VERTICAL FAN COIL UNITS

Transcription:

Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000* 121,000* 145,000* 175,000* Design CFM 3,200 4,000 4,800 6,000 Net Cooling Capacity 93,000** 115,000** 141,000** 168,500** Net Cooling CFM 3,200 3,600 4,800 5,000 EER 11.9 11.3 11.4 11.0 Compressor Qty/Type 2/Scroll 2/Scroll 2/Scroll 2/Scroll Evaporator Coil Type Enhanced Copper Tubes, Enhanced Aluminum Fins Dimension Height x Width (in) 28X52 28x52 34X67 34x67 Face Area (sq ft) 10.11 10.11 15.82 15.82 Rows/FPI 3/12 4/12 3/14 4/14 Filters Quantity/Size(in) 3 20x14x2 3 20x16x2 3 20x14x2 3 20x16x2 3 14x25x2 3 20x25x2 3 14x25x2 3 20x25x2 Condenser Coil Type Enhanced Copper Tubes, Enhanced Aluminum Fins Dimension Height x Width (in) 34X56 34X56 40X67 40X67 Face Area (sq ft) 13.22 13.22 18.61 18.61 Rows/FPI 4/14 4/14 4/14 4/14 Evaporator Fan Type Centrifugal, Forward Curved Qty. Diameter x Width(in) 1 15X15 1 15X15 2 15X11 2 15X11 Drive Adjustable Belt Motor HP (Standard) 1.5 2 2 3 Condenser Fan Type Centrifugal, Forward Curved Qty. Diameter x Width(in) 2 15X9 2 15X9 2 18X9 2 18X9 Drive Adjustable Belt Motor HP (Standard) 2 3 3 5 Dimension Height (in) 78 78 91.5 91.5 Width (in) 64 64 78 78 Depth (in) 32.5 32.5 34 34 Weight Operating (lbs) 1055 1110 1415 1480 Shipping (lbs) 1105 1170 1500 1565 *Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F web bulb and CFM listed. Gross capacity does not include the effect of fan motor heat. **Rated in accordance with ANSI/AHRI Standard 340/360 2007 1

DSV FAN PERFOMANCE DATA EVAPORATOR FAN PERFORMANCE MODEL # DSV096A DSV120A DSV144A DSV180A SUPPLY CFM 0.2 0.4 0.6 0.8 1.0 EXTERNAL STATIC PRESSURE - Inches W.C. 1.2 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3000 486 0.45 563 0.57 632 0.70 697 0.83 757 0.97 817 1.14 872 1.30 926 1.44 978 1.62 1028 1.80 3200 508 0.53 581 0.66 648 0.79 710 0.93 768 1.09 827 1.25 876 1.39 930 1.55 980 1.75 1030 1.91 3400 530 0.62 601 0.75 665 0.89 725 1.04 783 1.20 837 1.38 884 1.50 940 1.70 990 1.86 1040 2.02 3600 552 0.72 620 0.86 683 1.01 740 1.16 796 1.32 845 1.46 900 1.65 947 1.83 - - - - 4000 598 0.95 662 1.11 720 1.26 774 1.43 826 1.60 876 1.78 924 1.96 970 2.08 - - - - 4400 645 1.22 704 1.39 759 1.57 810 1.75 859 1.93 906 2.12 952 2.32 996 2.51 - - - - 4300 616 0.93 681 1.11 747 1.33 800 1.50 857 1.76 913 1.94 963 2.18 1017 2.45 1068 2.76 1110 2.91 4800 672 1.24 732 1.44 787 1.66 839 1.88 900 2.10 950 2.32 995 2.66 1050 2.84 1090 3.11 1134 3.40 5300 729 1.62 785 1.84 837 2.06 882 2.37 936 2.62 987 2.91 1025 3.00 1072 3.38 1115 3.65 1175 3.86 5400 741 1.70 796 1.93 847 2.15 896 2.42 944 2.62 988 2.85 1033 3.18 1078 3.44 1133 3.72 1166 3.95 6000 811 2.27 862 2.53 909 2.77 954 3.00 1000 3.31 1040 3.62 1080 3.88 1124 4.15 1164 4.48 1205 4.85 6600 882 2.97 929 3.25 973 3.52 1016 3.80 1054 4.05 1094 4.41 1134 4.72 1174 5.07 1212 5.37 1247 5.6 NOTE: 1. At high evaporator air flows, and wet bulb conditions, condensate carry-over may occur. Adjust airflow downward as necessary. 2. Values include pressure drop from wet coil and clean filters. 3. Shaded cells indicate oversized motors. CONDENSER FAN PERFORMANCE EXTERNAL STATIC PRESSURE - Inches W.C. MODEL # OUTDOOR CFM 0.2 0.4 0.6 0.8 1.0 1.2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP DSV096A 4700 642 1.20 704 1.40 764 1.61 815 1.82 869 2.00 923 2.30 DSV120A 5500 730 1.83 785 2.07 837 2.30 888 2.55 938 2.83 982 3.00 DSV144A 6600 637 2.26 683 2.53 728 2.82 770 3.10 810 3.40 848 3.68 DSV180A 7500 711 3.21 753 3.53 793 3.85 831 4.16 869 4.49 906 4.83 2

DSV ELECTRICAL DATA-STANDARD MOTOR MODEL # VOLTAGE COMPRESSOR EVAPORATOR FAN CONDENSER FAN MIN. CCT. MAX FUSE / QTY RLA LRA HP FLA HP FLA AMPACITY CCT. BKR. AMP DSV096A2 208-230/3/60 2 @ 15.3 83.0 1.50 4.6 2.00 6.0 44.94 60 DSV096A4 460/3/60 2 @ 6.2 41.0 1.50 2.1 2.00 2.8 18.79 20 DSV096A5 575/3/60 2 @ 4.8 33.0 1.50 1.7 2.00 2.1 14.60 15 DSV120A2 208-230/3/60 2 @ 16.0 110.0 2.00 6.0 3.00 8.5 50.45 60 DSV120A4 460/3/60 2 @ 7.8 52.0 2.00 2.8 3.00 4.0 24.30 30 DSV120A5 575/3/60 2 @ 5.7 38.9 2.00 2.1 3.00 3.1 18.03 20 DSV144A2 208-230/3/60 2 @ 19.0 123.0 2.00 6.0 3.00 8.5 57.20 70 DSV144A4 460/3/60 2 @ 9.7 62.0 2.00 2.8 3.00 4.0 28.58 35 DSV144A5 575/3/60 2 @ 7.4 50.0 2.00 2.1 3.00 3.1 21.85 25 DSV180A2 208-230/3/60 2 @ 23.2 164.0 3.00 8.5 5.00 13.8 74.50 90 DSV180A4 460/3/60 2 @ 11.2 75.0 3.00 4.0 5.00 6.6 35.80 45 DSV180A5 575/3/60 2 @ 7.9 54.0 3.00 3.1 5.00 5.2 26.08 30 DSV240A2 208-230/3/60 2 @ 30.1 225.0 5.00 13.8 5.00 13.8 95.33 125 DSV240A4 460/3/60 2 @ 16.7 114.0 5.00 6.6 5.00 6.6 50.78 60 DSV240A5 575/3/60 2 @ 12.2 80.0 5.00 5.2 5.00 5.2 37.85 50 DSV ELECTRICAL DATA-OVERSIZED MOTOR MODEL # VOLTAGE COMPRESSOR EVAPORATOR FAN CONDENSER FAN MIN. CCT. MAX FUSE / QTY RLA LRA HP FLA HP FLA AMPACITY CCT. BKR. AMP DSV096A2 208-230/3/60 2 @ 15.3 83.0 2.00 5.6 2.00 6.0 45.97 60 DSV096A4 460/3/60 2 @ 6.2 41.0 2.00 2.8 2.00 2.8 19.45 25 DSV096A5 575/3/60 2 @ 4.8 33.0 2.00 2.1 2.00 2.1 15.00 15 DSV120A2 208-230/3/60 2 @ 16.0 110.0 3.00 8.5 3.00 8.5 53.00 60 DSV120A4 460/3/60 2 @ 7.8 52.0 3.00 4.0 3.00 4.0 25.55 30 DSV120A5 575/3/60 2 @ 5.7 38.9 3.00 3.1 3.00 3.1 19.03 20 DSV144A2 208-230/3/60 2 @ 19.0 123.0 2.00 6.0 3.00 8.5 57.20 70 DSV144A4 460/3/60 2 @ 9.7 62.0 2.00 2.8 3.00 4.0 28.58 35 DSV144A5 575/3/60 2 @ 7.4 50.0 2.00 2.1 3.00 3.1 21.85 25 DSV180A2 208-230/3/60 2 @ 23.2 164.0 5.00 13.8 5.00 13.8 79.80 100 DSV180A4 460/3/60 2 @ 11.2 75.0 5.00 6.6 5.00 6.6 38.40 45 DSV180A5 575/3/60 2 @ 7.9 54.0 5.00 5.2 5.00 5.2 28.18 35 DSV240A2 208-230/3/60 2 @ 30.1 225.0 5.00 13.8 5.00 13.8 95.33 125 DSV240A4 460/3/60 2 @ 16.7 114.0 5.00 6.6 5.00 6.6 50.78 60 DSV240A5 575/3/60 2 @ 12.2 80.0 5.00 5.2 5.00 5.2 37.85 50 3

DSV-SERIES VERTICAL AIR-COOLED SELF-CONTAINED UNIT GENERAL MECHANICAL SPECIFICATIONS GENERAL The 8 10 ton units ship as factory charged unitized packages. The 12 and 15 ton models shall be shipped as separate evaporator and condensing unit models (nitrogen holding charge only). All units may be field split and installed as separate modules to suit on site requirements. All packages are designed for free standing mounting on the floor, or on a field fabricated structural steel stand. The 8 and 10 ton models are shipped with vertical evaporator fan discharge as standard. The 12 and 15 ton models are shipped with horizontal discharge as standard. CABINET All cabinets are completely constructed of heavy gauge galvanized steel. The entire unit interior (both evaporator and condensing section) is insulated with 1/2" thick, 2 lb density insulation. Service panels are equipped with lifting handles for ease of removal and handling. Duct flanges for condenser discharge, condenser intake, and evaporator discharges are provided with the unit for field installation. Duct flange on evaporator return is incorporated into the filter frame. COMPRESSORS All models utilize "Scroll" type, R 410A, hermetic compressors. Compressors are mounted on rubber isolators to minimize vibration transmission. Internal overload protection is provided. External high pressure and low pressure cut out switches are included in each compressor control circuit. The 8 15 ton units have two individual scroll compressors. REFRIGERANT CIRCUITS The 8 15 ton units feature two independent refrigeration circuits. Each refrigeration circuit includes an adjustable thermal expansion valve (with external equalizer), liquid line filter drier, sight glass/moisture indicator, and service gauge ports. EVAPORATOR AND CONDENSER COILS The evaporator and condenser coils are constructed of internally enhanced copper tubes mechanically bonded to rippled aluminum plate fins. Both coils are employed in a draw thru configuration. Large evaporator coil face area minimizes potential water blow off. INDOOR/OUTDOOR FANS Forward curved, double inlet and double width centrifugal blowers are used for both evaporator and condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearings. All blowers are belt driven. Variablepitch motor sheaves allow for field adjustment of blower rpm. Motor shall be 1750 RPM, open drip proof design. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. Manual reset protection is provided on both evaporator and condenser motors. A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cut out. Time delay relay will be provided for each compressor circuit. Compressor will be locked out for 5 minutes when thermostat contact opens, or there is a momentary power outage. A 24 volt control circuit, with oversize transformer, is provided for field connection. FILTERS All models are shipped with 2 inch thick medium efficiency throwaway filters factory installed. Filter rack is external to the cabinet (shipped loose). 4

FACTORY INSTALLED OPTIONS Oversized Evaporator Fan Motors Increased horsepower motors and drive components are available for those applications where external static pressure requirements exceed the capability of the standard motor. Corrosion Resistant Coatings Condenser and/or evaporator coils shall receive a 1 mil thickness of a cathodic epoxy type electro deposition coating, applied in a multiple dip and bake process. Stainless Steel Drain Pan Evaporator drain pan shall be fabricated of 304 stainless steel material. The 3/4 in NPT drain connection fitting is also constructed of 304 stainless steel. FIELD INSTALLED ACCESSORIES Low Ambient Control Head pressure control damper kit will allow unit operation down to 0 F ambient. Damper assembly mounts on condenser air intake. The kit includes damper actuator and low pressure switch bypass timer(s). Airside Economizer APPLICATION Johnson Control s air side economizers are designed to meet current building and legislated codes for indoor ventilation. In addition to improving indoor air quality, economizers provide substantial energy savings by utilizing cool outside air instead of mechanical cooling whenever outside conditions permit. The outlet or discharge of the air side economizer is fitted to the return air inlet of the packaged air conditioning unit. The two inlets to the economizer are fitted to the return air and outside air ductwork. Opposed blade dampers located in each inlet modulate the incoming air streams as they enter the mixing box. The outside air damper can be maintained at a predetermined minimum position. In this way the buildings ventilation requirements can be met at all times. General Consisting of an integrated mixing box and control assembly, the economizer mates easily to all Skymark horizontal and vertical air handlers. A factory supplied wiring harness and jack plug assembly simplifies field wiring, reducing valuable installation time. No additional controls or transformers are necessary to complete the installation. Mixing Box The mixing box is manufactured from heavy gauge steel and completely insulated with one half inch of insulation. The mixing box is complete with fully modulating opposed blade dampers and linkage. Low Leakage Low leakage dampers meet the criteria of less than 10 cfm per square foot at 4 w.g. (0.5% at 2000 fpm). All damper blades are provided with neoprene seals providing a tight seal and quiet operation. W7215 Economizer Control Module The W7215 is a multi functional controller capable of analyzing dry bulb, enthalpy and air quality inputs. An output from the economizer module will position the mixing box dampers to provide energy saving through the introduction of outside air for free cooling. 5

SUPPLY AIR OPTIONAL DISCHARGE (44" REQUIRED FOR SHAFT REMOVAL) A ELECTRICAL BOX LOCATION 36" MINIMUM SERVICE FRONT VIEW RETURN AIR FILTERS ELECTR. POWER CABLE ENTRANCE DETAIL A B 3 4 NPT DRAIN CONNECTION DETAIL B BACK VIEW CONDENSER INTAKE DESCRIPTION: Form: DSV096/120 VERTICAL DSV120-USS-00-1 AIR-COOLED SELF-CONTAINED Date: AIR CONDITIONERS SUBMITTAL DIMENSIONS 8/17/2009 6

OPTIONAL DISCHARGE (44" REQUIRED FOR SHAFT REMOVAL) A ELECTRICAL BOX LOCATION FRONT VIEW 36" MINIMUM SERVICE DETAIL A ELECTR. POWER CABLE ENTRANCE 3 4 NPT DRAIN CONNECTION B DETAIL B BACK VIEW CONDENSER INTAKE DESCRIPTION: Form: DSV144/180 VERTICAL DSV180-USS-00-1 AIR-COOLED SELF-CONTAINED Date: AIR CONDITIONERS SUBMITTAL DIMENSIONS 8/17/2009 7