Computer-based Alarm Processing and Presentation Methods in Nuclear Power Plants

Similar documents
Application of Logic Alarm Cause Tracking System to Shinhanul 1&2 Nuclear Power Plants

Modeling of Vibration Monitoring of Steam Turbine in Nuclear Power Plant using Modular Artificial Neural Network

Effective Alarm Management for Dynamic and Vessel Control Systems

Cable Selection and Detailed Circuit Analysis on Plant under Construction

Fire Risks of Loviisa NPP During Shutdown States

Fire Test Evaluation using the Kerosene and Aviation Fuel

Design Characteristics and Classification Issue of the I&C Systems for the JRTR

I&C Upgradation and Modernization at CHASNUPP 1 & 2. Presented By: Waseem Uddin Farooqi PAEC, Pakistan

02 21st Century Trends Resources 8/24/2017. Trends in Human Machine Interface (HMI) Old School Trends. The Future of HMI

Licensing of FPGA-based Safety Platform RadICS: Case Study

Lata Mishra Bhabha Atomic Research Centre, INDIA

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES

XA ALARM HANDLING SYSTEMS AND TECHNIQUES DEVELOPED TO MATCH OPERATOR TASKS

Post Accident Monitoring in PFBR Safety in Nuclear Power Plant

Criteria I&C and Inherent Characteristics

Brazil. Current status in NPP I&C and Discussion Topics. 24th Meeting of the IAEA TWG-NPPIC

Numerical Standards Listing

Fin-Fan Control System

Development of Post-Accident Monitoring System for Severe Accidents

Numerical Standards Listing

SCADA 101 Introduction to SCADA Systems - Sensors, Data and Screens

Real-Time Root Cause Analysis for Complex Technical Systems

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Alarm System Performance Metrics

I/A Series A 2 Software FoxAlert Alarm Manager

LPG GAS LEAKAGE DETECTION, MONITORING AND CONTROL USING LabVIEW

A Study on Smart City Development Project for Regional Innovation: Co-creation and Design Thinking Approach

Fire Protection Regulatory Approach for Nuclear Power Plants in Canada

Upward Evacuation Experiment for Estimating Evacuation Speed in Water Disaster

Numerical Standards Listing

ALARM SYSTEMS. Abstract

A Study on Cooling Rate with Blade and Sound Fire Extinguisher

Chapter Master Planned Communities (MPC) District

Nuclear or Radiological Emergencies & Management of Radiological Accidents RADKOR 2017

Development of Smart Phone Applications Linked with Fire Alarm Control Panel in Automatic Fire Detection System

Implementation of Auto Car Washing System Using Two Robotic Arms

Sensor Technology. Summer School: Advanced Microsystems Technologies for Sensor Applications

A Study on the Characteristics of Planning within Analyzing of Exterior Space in Mixed-use Development 1

Alarm Management Plan

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

IEC/SC45A. I&C for nuclear facilities. Jean-Paul BOUARD IEC/SC45A Secretary. IAEA TWG meeting on I&C 24 th -26 th May 2011, IAEA - VIC 1/10

Lecturer: Jim Clauston. Course: QAS 515 Human Factors Engineering in Quality. Term Paper Title: Alarm Management on an Oil & Gas Offshore Platform

Secondary Systems: Condensate/Feedwater Cycle

IAEA SAFETY STANDARDS

Current Trends in SCADA Systems. Situational Awareness Alarm Management Data Availability System Robustness/Redundancy

IOT Based Intelligent Bin for Smart Cities

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Air Liquide Advanced Technologies Division Sassenage, 38360, France

Intrusion Detection System: Facts, Challenges and Futures. By Gina Tjhai 13 th March 2007 Network Research Group

Alarm Management for SCADA control rooms

ALARMING NEWS FROM INVENSYS PROCESS SYSTEMS, INC.

An Instrumentation and Control for Loop Test

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA

AS/NZS IEC :2013

Atomic Energy Licensing Board

BOILED WATER TEMPERATURE MEASUREMENT SYSTEM USING PIC MICROCONTROLLER

Embracing Change: High Performance Graphics to Improve Operations Water/Wastewater Case Study

Results of Recent DOE Research on Development of Cable Condition Monitoring and Aging Management Technologies

White Paper. Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System

Regulations for Fire Protection in Japan

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

Adsorption refrigeration system using waste heat

Air Conditioning System Sizing for Pure Electric Vehicle

Modified geotextile tube a new geotextile tube for optimized retaining efficiency and dewatering rate

TECHNICAL REPORT IEC TR 62987

Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM

Is your current safety system compliant to today's safety standard?

Regulatory Perspective for Fire Protection and Emergency Management at Nuclear Facilities in Canada

Performance Analysis of Water-Water Heat Pump System of 100 kw Scale for Cooling Agricultural Facilities

Table of Contents PART I: The History and Current Status of the Industrial HMI PART II: Fundamentals of HMI Design and Best Practices

THE SMOKING-MATERIAL FIRE PROBLEM

Stavros Chrysanthou Madrid DynAMo Alarm Management Secrets to unlocking complete Operational Integrity

Control System Studio - CSS - Alarm Handling

Avigilon Control Center 5 System Integration Guide

Meeting PHMSA Alarm Management Requirements: How TiPS Can Help

Alarm Analysis with Fuzzy Logic and Multilevel Flow Models

Session Objectives: Significance: 15/03/2017. Networked Crisis Communication:

DEVELOPMENT OF HOME FURNISHING ITEMS BY ADAPTING LANDSCAPE DESIGNS THROUGH CARPET WEAVING TECHNIQUE

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362,

Defense Nuclear Facilities Safety Board Mission & Operations

Comparative study of the conventional and optical communication analog fire detector signal attenuations with various number of fire detectors

A Novel VLSI Based Pipelined Radix-4 Single-Path Delay Commutator (R4SDC) FFT

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Room Temperature Control and Fire Alarm/Suppression IoT Service Using MQTT on AWS

Integrated Knowledge Base Tool for Acquisition and. Verification of NPP Alarm Systems

Neurofuzzy Computing aided Fault Diagnosis of Nuclear Power Reactors

IMAGE PROCESSING BASED FIRE DETECTION ANDALERT SYSTEM

ISSN Vol.04,Issue.12, September-2016, Pages:

Visual analysis on the nightscape lighting for the pedestrian and greenery zone of a neighborhood park

Dae-Hyun Jin. 8/2018-Present Assistant Professor of Mechanical Engineering, Taylor University, USA

SELF PRESERVATION SOCIETY By Jim Creak

Software Failure Mode and Effects Analysis of Concept Phase for Radiation Monitoring System Digital Replacement

Part 1 General Part 2 Indenter modulus Part 4 Oxidation Induction methods Accepted by IEC and IEEE for publication Published in September 2011

Evaluation of the Reduction of Rainwater Runoff from a Green Roof

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Performance of an Improved Household Refrigerator/Freezer

Reactor Protection Systems for the Replacement Research Reactor, ANSTO

6367(Print), ISSN (Online) Volume (IJCET) 3, Issue 2, July- September (2012), IAEME

Transcription:

Computer-based Alarm Processing and Presentation Methods in Nuclear Power Plants Jung-Woon Lee, Jung-Taek Kim, Jae-Chang Park, In-Koo Hwang, and Sung-Pil Lyu Abstract Computerized alarm systems have been applied increasingly to nuclear power plants. For existing plants, an add-on computer alarm system is often installed to the control rooms. Alarm avalanches during the plant transients are major problems with the alarm systems in nuclear power plants. Computerized alarm systems can process alarms to reduce the number of alarms during the plant transients. This paper describes various alarm processing methods, an alarm cause tracking function, and various alarm presentation schemes to show alarm information to the operators effectively which are considered during the development of several computerized alarm systems for Korean nuclear power plants and are found to be helpful to the operators. Keywords Alarm processing, Alarm presentation, Alarm cause tracking, Alarm logic diagram computerization, Alarm pattern recognition. I. INTRODUCTION AJOR functions of alarm systems in nuclear power plants M(NPPs) alert the operator to the fact that a system or process deviation exists and inform the operator about the priority and nature of the deviation [1]. Since many process systems in NPPs are interlinked together, a malfunction in a system affects other systems and consequentially activates many alarms. During plant transients, such as a setback, stepback, reactor trip, and turbine trip, several tens, or in some cases several hundreds, of alarms can occur during a very short period of time. Alarm systems in many operating NPPs, which do not use computers, display alarms on only alarm windows located at the top part of control panels in the control rooms. In these alarm systems, alarm window tiles are connected to alarm signals by hardwire. When an alarm avalanche occurs, these alarm systems cannot provide the operators with appropriate cues to the situation. Computers have been utilized increasingly in NPPs. Alarm support systems are added to the control rooms of operating NPPs to help the operators to detect the situation and to respond to the malfunctions appropriately. Various alarm processing Jung-Woon Lee is with the Korea Atomic Energy Research Institute, Daejeon, The Republic of Korea (corresponding author to provide phone: 82-42-868-8322; fax: 82-42-868-8916; e-mail: leejw@ kaeri.re.kr). Jung-Taek Kim, Jae-Chang Park, and In-Koo Hwang, are with the Korea Atomic Energy Research Institute, Daejeon, The Republic of Korea (e-mails:. jtkim@kaeri.re.kr; jcpark@kaeri.re.kr; ikhwang@kaeri.re.kr). Sung-Pil Lyu is with the Department of Computer System, Semyung University Jecheon Si, Chungcheongbuk-Do, The Republic of Korea (e-mail: lsp415@semyung.ac.kr). methods such as alarm reduction, alarm prioritizing, and alarm grouping become feasible by use of computerized alarm systems. Many ways of alarm presentation, including not only on conventional alarm windows but also on visual display units (VDUs) in the computerized control rooms, become also possible. For new NPP designs, these functions are integrated into the instrumentation and control system and the human machine interface. Computerized alarm systems present processed alarms mostly in an alarm message list format on one or two VDUs. This type of alarm presentation still has problems for the operators in their recognition of alarm situations. Many alarms occurring during the plant transients may be displayed on many pages of alarm display screens, which cause the operators to be overwhelmed [2]. Computer-based alarm processing and presentation systems have been developed for several different Korean NPPs [3]-[7]. The alarm cause tracking function that these systems have is a unique feature helpful to the operators. This paper describes the methods for alarm processing, alarm cause tracking, and alarm presentation schemes. II. ALARM PROCESSING METHODS Many systems and equipment are interlinked together in NPPs, A malfunction in a system or equipment affects other systems to consequentially activate many alarms. Alarm avalanches during the plant transients cause problems to the control room operators with both conventional analog alarm systems and new computerized alarm systems. It is crucial to the operators that alarm systems select and present the alarms which are important and causal to the transient situations. In order to handle alarm avalanches, many methods to reduce the number of alarms have been implemented throughout the development of computerized alarm systems. With these systems, less than thirty causal alarms can be collected from hundreds of alarms during the plant transients. A. Mode Dependency Processing This is a very popular method to reduce the number of alarms. During a change in the plant operation mode, the following situations may occur; a) temporary plant transients, b) changes in a line-up configuration of systems, c) out-of-service systems or components, and d) on or off of some pumps or valves due to a change in the demand. Many alarms are temporarily generated due to the above situations. Alarms can be prioritized in accordance with their characteristics during a change in the plant operation mode. If alarms are activated temporarily and 940

consequentially to setback, stepback, reactor trip, or turbine trip, these alarms are treated as non-causal and usual. B. Cause-Consequence Relationship Processing Some alarms are generated by cause-consequence relationships with other alarms. In this cause-consequence processing, once causal alarms and consequential alarms are identified by the analysis of alarm relationships, consequential alarms are treated as not-important alarms. Fig. 1 shows a concept of this cause-consequence relationship when the feedwater pump 04P trips due to the alarm signal FWBP 04P Lube Oil Press LoLo [P2]. The alarms, RCPS ACTu[P1-P2] and MFWP 01P Trip [P2-P3] are generated due to FWBP 04P Trip [P2-P3]. Here, Oil Press LoLo [P2] becomes a causal alarm and the other alarms are the consequential alarms. FWBP 04P Running Oil Press lo(p2) No r mal Rx Trip Oil Press lolo(p2) (Caused Alarm) Raw Alarm Mode, Status FWBP 04P Tr ip(p2) Level Precursor MFWP 01P Tr ip(p2) Rx PWR>75% RPCS ACTu(P1) Cause- Consequence Oil Press lo(p2 - P3) (Level Precursor) Oil Press lolo(p2) (Caused Alarm) RPCS ACTu (P1 - P2) MFWP 01P Trip (P2 - P3) FWBP 04P Trip (P2 - P3) Alarm Presentation Fig. 1 An example of cause-consequence relationships of alarms C. Level Precursor Processing There are many alarms related to the same monitoring parameter. For example, alarms related to the levels of steam generators, condenser hotwells, and deaerators exist at several alarm set-points according to the significance of plant transients. In the case that an alarm for a more severe state is activated, alarms for less severe states are not meaningful and can be treated as usual alarms. For instance, the priority of the alarm Steam Generator A Water Level Low is lowered when the alarm Steam Generator A Water Level Low-Low is also activated. D. Interlock Equipment Processing Some alarms are interlinked to plant components. These alarms do not have meanings if the components are out of service. For example, an alarm CEP DISCH HDR PRESS LO has no meaning if the condenser pumps (CEPs) are out of service and can be represented by a composed input alarm CEP TRIP. E. Common Resource Processing There are common resources such as compressed air or electricity to be supplied to plant components. These common resources are supplied in common lines with multiple trains. When a malfunction occurs in a common resource supply system, many alarms are activated in relation to the components receiving resources from the common resource supply system. These alarms can be represented by an alarm of the common resource supply system. For example, when many alarms occur due to trips in the air supply system or the electrical supply system, "Air Supply System Train A Trip" or "Electrical Supply System Train B Trip" can be a representative alarm and other alarms can be treated as usual alarms. F. Alarm-Status Separation Processing In some cases, alarms may indicate an automatic activation of plant components. These alarms are classified as status alarms in our alarm processing and displayed separately to other alarms. Operators also expressed that alarm-status separation would be necessary [8]. Not important alarms are also classified separately from causal alarms. Some examples of these are deviation alarms by a malfunction of reluctant sensors or equipment, alarms for a door open or key-unlock related to periodic tests, and minor alarms not affecting power reduction such as one for blocked strainers. III. ANALYSES OF ALARM DATA AND PROCESSING In order to apply the above alarm processing methods, a careful analysis of alarms becomes critical in the development of computerized alarm systems. All alarms of the NPPs, to which these alarm systems may be applied, were analyzed by using the alarm signal information, the alarm procedures, the abnormal and emergency operation procedures, the control logic drawings, and the plant process drawings. A standard sheet of the alarm analysis as shown in Fig. 2 was developed and used for the alarm analysis. Information related to alarm signals, alarm processing, alarm causes, alarm classification, and so on, can be filled after the analysis. The results are stored in a database. Hence a database management program can handle them easily to perform the alarm processing. Fig. 2 Alarm analysis sheet IV. ALARM CAUSE TRACKING A. Two Alarm Cause Tracking Methods Alarms are originally generated from malfunctions in the 941

plant components or sensors. It is helpful to the operators to show active causes when alarms are generated. We used two methods to track alarm causes. One is to use the alarm database which has information of alarm causes. When an alarm is activated, the alarm system can check and report whether any signals of alarm causes corresponding to the alarm are alive. In another way, the control logic diagrams were computerized and used for the alarm cause tracking. The alarm system tracks logic links in computerized logic diagrams from an activated alarm to alarm cause signals to find the causes of the alarm. The alarm system reports active alarm signals resulted from the logic diagram tracking. With this unique feature, the operators can see only active causes for the situations and need not to see other inactive causes for alarms. B. Computerization of Alarm Logic Diagrams Alarm logic diagrams are drawings graphically representing the status of links between logic elements implemented on plant equipment. A hard copy logic diagram as shown in Fig. 3 can be represented by using a simple text editor then converted into a computerized logic diagram as shown in Fig. 4 by using a logic diagram execution program. Fig. 3 A hard copy logic diagram Fig. 4 A computerized logic diagram of the hard copy logic diagram When these alarm systems are executed, if the value of a logic element implies that the logic element is active, then the colors of the logic element and adjacent signal lines are changed to show signal flows. Fig. 5 shows an example of the active logic elements and the signal flows. Fig. 5 An example of the active logic elements and the signal flows V. LINKS TO ALARM RESPONSE PROCEDURES (ARPS) The operators can handle alarms by using ARPs. The causal alarms are linked to a corresponding ARP in our alarm system. ARPs are computerized for this purpose. The operators can select a causal alarm then they can view ARP corresponding to the alarm. ARPs usually note many causes of an alarm. In these systems, only causes which are active at the situations are highlighted as shown in Fig. 6. In this way, the operators can follow the ARPs without questioning which causes are active. Fig. 6 An ARP display with the active cause highlighted VI. PRESENTATION OF ALARMS As shown in Fig. 7, alarm windows are placed at the top of the control panels in the conventional control rooms of NPPs. Alarm windows are grouped by the systems, and sometimes, alarm tiles have different colors according to their importance. During the plant transients, since too many alarms are activated, the operators do not look at the windows. However, in cases where not many alarms are activated, the operators can figure out the situations at a glance by recognizing a pattern of activated alarm tiles. 942

Fig. 7 Alarm windows in the conventional control rooms Fig. 8 shows an example of a computerized alarm system display. This alarm system is a part of the Korean advanced control room design. Fig. 9 An alarm display to support alarm pattern recognition Fig. 8 An example of computerized alarm system displays In this type of display, alarm messages are presented by text lines. Alarm messages can be rearranged and sorted according to alarm priorities or related plant systems as the operators want to. However, the operators who have an experience of operating this alarm system complain that the system does not support their alarm pattern recognition and sometimes gives difficulties to their understanding of the situations in a short time. Considering the pattern recognition, a replica of alarm windows was implemented as an alarm presentation display of the alarm systems for an operating Korean NPP (Fig. 9). With this type of alarm display, the operators can maintain their visual momentum that they have formed through the real alarm windows. They also can feel familiar when they operate the alarm system. Another example of the alarm system display is shown in Fig. 10. This NPP has already a computerized alarm system. However, since the system was designed a long time ago, the display is very primitive and presents only 20 alarm message lines on a screen as shown in Fig. 11. As shown in Fig. 10, the alarm support system for this NPP shows an original alarm message list on the right window and a list of causal and important alarm messages compressed from the original alarms on the top left window. The operators can see the causes of a specific alarm selected from the list of causal and important alarm messages on the bottom left window. Further by selecting a cause from the alarm cause window, the operators can view a logic diagram pop-up window demonstrating the logic links from the alarm to the cause. Fig. 10 Another example of our alarm system displays 943

Fig. 11 A CRT alarm message display of an old NPP VII. DISCUSSION Alarm systems are important in safe operations of NPPs. In order to handle alarm avalanches, alarm processing is necessary to reduce the number of alarms. It is found that showing causal and important alarms separately during the plant transients helps the operators to mitigate the transients. The alarm cause tracking function, which shows active causes of a specific alarm, is also helpful to the operators. Also, links to the ARPs with active cause highlighting in these alarm systems help to reduce operator response time. For alarm presentation matters, it is important that the systems should provide alarm presentation formats in ways familiar to the operators. Alarm pattern recognition capabilities, which the operators have acquired through their operation with conventional alarm systems, should be supported also in a new computerized alarm system design. REFERENCES [1] William S. Brown, John M. O'Hara, and James C. Higgins, Advanced Alarm Systems: Revision of Guidance and Its Technical Basis, NUREG/CR-6684, U.S. Nuclear Regulatory Commission, Washington, DC, 2000. [2] John M. O Hara, William F. Stubler, and James Higgins, Hybrid Human-System Interfaces: Human Factors Considerations, BNL Report J6012-T1-4/96, December 11, 1996. [3] Jung Taek Kim, et. al, An Evaluation Approach for Alarm Processing Improvement, IAEA Specialists Meeting (IWG-NPPCI) on Experience and Improvements in Advanced Alarm Annunciation Systems in Nuclear Power Plants, Chalk River, Ontario, Canada, 1996. [4] Jung-Taek Kim, Kee-Choon Kwon, In-Koo Hwang, Dong-Young Lee, Won-Man Park, Jung-Soo Kim, and Sang-Jeong Lee, Development of advanced I&C in nuclear power plants: ADIOS and ASICS, Nuclear Engineering and Design, 207, pp.105 119, 2001. [5] Sung P. Lyu, An Identification of Alarm Cause by Tracking Logic Diagram, 2002 Spring Conference, Korea Nuclear Society, May 2002. [6] Jung-Taek Kim et al., An Application on Alarm Root Cause Tracking System (ACTs), Joint 8th Annual IEEE Conference on Human Factors and Power Plants (HFPP) and 13th Annual Workshop on Human Performance / Root Cause / Trending / Operating Experience / Self Assessment (HPRCT), Monterey, CA, 2007. [7] Jung-Woon Lee et al. LOGACTS (Logic Alarm Cause Tracking System) for a Nuclear Power Plant Operation, Sixth American Nuclear Society International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies, NPIC&HMIT 2009, Knoxville, Tennessee, April 5-9, 2009. [8] Emilie Roth and John O'Hara, Integrating Digital and Conventional Human-System Interfaces: Lessons Learned from a Control Room Modernization Program, NUREG/CR-6749, U.S. Nuclear Regulatory Commission, Washington, DC, 2002 944