mcr PROLIGHT, mcr PROLIGHT PLUS

Similar documents
MCR9705 Smoke and Heat Exhaust Control Unit

Smoke Vents. Certified to CE EN Roof Access Systems

OPERATION AND MAINTENANCE MANUAL

OPERATIONAL AND MAINTENANCE MANUAL. Overpressure smoke control system for vertical exit paths mcr EXi

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

THE SMOKE AND ACCESS SPECIALISTS. Compliance without compromise

LAMILUX BUILDING CONTROL SYSTEMS ENERGY EFFICIENCY SAFE COMFORTABLE. Customized Intelligence Serving the customer is our first priority

SMOKE AND HEAT EXHAUST VENTILATION SYSTEMS SAFETY DUE TO APPROVED SMOKE OUTLET DEVICES EN COMPLIANT AND ECONOMICAL

TECHNICAL MANUAL. Power and Control Panel mcr OMEGA

THE SMOKE MUST GO. Consulting - Project Planning - Supply - Installation - Service

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

Schueco Fire and Smoke Protection Systems

Performance Specifications LSF LIFT-SMOKE-FREE

Aspects of Fire Regulations and Standards in the Atrium

Mechanical smoke ventilation systems. CI/SfB 37.4 Xy

WINDOW AUTOMATION SOLUTIONS NATURAL AND SMOKE VENTILATION SYSTEMS

TECHNICAL MANUAL. Power and Control Panel mcr OMEGA pro

technical specification smoke venting systems

Sonos-SB Siren/Beacon

ESCAPE WAYS IN RESIDENTIAL BUILDINGS

Fire Performance of Translucent Systems

PRODUCT DESCRIPTION. Renovation smoke exhaust fumivent VdS

Uniclass L7535: N3253 EPIC L13:Y42. CI/SfB (57) X (K5) Residential Smoke Ventilation

Princess Court Cornbrook Park Road Old Trafford Manchester M15 4FE

Smoke is the most deadly part of a fire.

TUNNEL FANS STANDARD AND HOT SMOKE

Fire Safety Concept Hotel Jumeirah

Smoke / Natural Ventilation. simplicity & versatility. Smoke / Natural Ventilator Car Park Smoke Control Fire & Smoke Curtains Control Systems

HATCHES & VENTS. Roof hatches - Camec Roof hatches Vents and cowls...208

Product Information October (8) Orivent 51 in Itella, Pennala. Orivent 01 in Oriville factory, Orimattila

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

INTEGRATED LOUVERS in Doors and Openings FOR VISION AND DAYLIGHT CONTROL

HEAT & SMOKE VENT INSPECTION AND MAINTENANCE PACKET

Spray sprinkler system

D+H EURO-SHEV: Smoke ventilation according to DIN EN

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Fire Safety Guidelines

SGG CONTRAFLAM LITE SAINT-GOBAIN GLASS PROTECT

Moffitt Firex. Heat & Smoke Ventilator. MoffittCorp.com (800) th Ave S. Suite 130 Jacksonville Beach, FL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

Mechanical Smoke Extract Shaft Systems

PREMISES FIRE SAFETY LOGBOOK

This document is a preview generated by EVS

XC10 combined fire detection and extinguishing control

Üntel is ready for CPR

NFPA-APSEI Fire & Security 2010

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Smoke control and access systems. CI/SfB 37.4 Xy

NATURAL VENTIL ATION. commercial louvres solar shading design consultancy sales and installation natural ventilation

The Social Accountability International (SAI) Fire Safety Checklist

Fire Safety Checklist

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

Fire Safety Fire Resistant Building Components

BuyLine /CON. apcdayliter. Fire and Smoke Vents. Smoke is the most deadly part of a fire

Kædemotorer. Product Overview

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

SYSTEMS PRODUCT OVERVIEW

U C S AND AUTOMATION SYSTEMS

Part No KEMPER Filter-Master XL

FIRE POLICY ST.GEORGES AND OUR LADY QUEEN OF PEACE PARISHES OF WORCESTER INTRODUCTION. Fire is one of the most common workplace hazards.

NOVOLAY secure. PYRANOVA secure. Special glass types with outstanding safety properties

YOUR GUIDE TO UNDERSTANDING CPR

Assessment details. You can use this form to record a fire safety assessment of simple premises. Address. 123 Station Rd Brigadoon

General Principles of Smoke Control

Fire Protection. Fire-resistant glasses. Pilkington Pyrostop Fire Resistance Glass Pilkington Pyrodur Fire Protection Glass

Enclosure 4- RISK ASSESSMENT

The Bilco Company has partnered with industry pioneer Colt to bring dual purpose natural and smoke ventilation products to North America.

FIRE SAFETY LOGBOOK ADDRESS OF PREMISES NOMINATED RESPONSIBLE PERSON

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

UNIVERSITY COLLEGE LONDON PREMISES FIRE SAFETY HANDBOOK. Regulatory Reform (Fire Safety) Order 2005 DARWIN BUILDING

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Fire Protection. Intumescent fire and smoke seals for door assemblies

Protect human life against hazards at refineries and other sensitive. Complete cabin protected against blast, gas, fire and smoke

PHA Panic Hardware for timber doors

EUROPEAN TECHNICAL ASSESSMENT

EUROPEAN TECHNICAL ASSESSMENT

ACTIVE FIRE CURTAINS INTISI7

Western Firex. Heat & Smoke Ventilator. EAGLE series Natural Ventilation

Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house

Fire Evacuation Plan for ROSE Lab

INTEGRATED SMOKE CONTROL SOLUTIONS

ICARO. Aircraft Warning Lights GENERAL CATALOGUE

Product information Flat glass product ISD for VELUX flat roof windows CFP/CVP Integra

1.4 Provide and fix the following ironmongery.

LANDE SmartQube 19 Air-Conditioned Cabinet

SHEVTEC Extended Travel Distance. System for Chettles Yard, Nottingham

Uniclass L7535 EPIC L13. CI/SfB (57) X. secontrols.com. Smoke Ventilation, Natural Ventilation and Window Automation

Where life thrives. Why a Growing Dome? Wellbeing. Stability. Safety. Made in America

Fire Risk Assessment

SMOKE MANAGEMENT AND EGRESS ANALYSIS OF A SPORTS ARENA USING THE PERFORMANCE-BASED DESIGN

THE MAURITIUS FIRE AND RESCUE SERVICE ACT. Regulations made by the Minister under sections 18, 19 and 27 of the Mauritius Fire and Rescue Service Act

ISO INTERNATIONAL STANDARD

Who are we? LGF SYSMAC a 15 Years Young and Vibrant Company Characterized by

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager

AIR HANDLING UNITS MANDÍK

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Transcription:

mcr PROLIGHT, mcr PROLIGHT PLUS smoke exhaust vents, skylights, roof access hatches

The fire causes the release of large amounts of smoke and hot gases in the building that can be dangerous for people inside. The priority in such a case is to evacuate people as soon as possible and to start fighting the fire in order to reduce losses of properties. In order to achieve this, it is important to remove smoke from evacuation routes and to lower the smoke temperature, which also mitigates the risk of the building structure damage. In order to achieve the above goals, natural smoke exhaust systems are designed with their basic elements, which include mcr PROLIGHT smoke exhaust ventilators and control devices. Mercor offers comprehensive solutions within the area of fire safety for various types of premises, starting from large format halls to staircase smoke exhaust systems. In order to meet the various requirements of our customers, we have elaborated a whole range of smoke exhaust vents that additionally may have the function of ventilation flaps, spot skylights or regular roof access hatches.

ADVANTAGES OF SPOT SMOKE EXHAUST VENTS Variety of shapes Many types of smoke vents available in many shapes and optional fittings A wide range of dimensions Manufacturing of custom-made sizes to meet the customer demands is our standard service. Non-standard solutions The preparation of non-standard variants of vents according to an architect s vision is also possible on request. Choice of active surface Adjusting active area of the smoke vent by optional fitting elements that enhance its parameters (wind deflectors, inlet deflectors) Multifunctionality Spot smoke vent may provide several functions at the same time, e.g.: smoke and heat exhaust, daily ventilation, supply of daylight and roof access Operational reliability Excellent technical parameters of smoke exhaust vents ensure their operational reliability Certificates product classification according to the Certificate of Constancy of Performance no. 1396-CPR-040 pursuant to EN 12101-2 production management process according to ISO 9001:2008

mcr PROLIGHT SMOKE EXHAUST VENTS type C and E Single leaf vents with upright base size range for C type vents (square) 100 x 100 cm 200 x 200 cm size range for E type vents (rectangular) 100 x 120 cm 200 x 250 cm AERODYNAMICAL ACTIVE AREA With the application of optional elements increasing the active smoke exhaust surface (wind and inlet deflectors), it is possible to reach the max. value of 3.24 m² (type C) or 4.05 m² (type E) CONSTRUCTION OPTIONS A whole range of smoke exhaust vents types and a wide portfolio of optional elements can be applied in order to implement the most demanding customer requests Leaf filling that affects heat transfer coefficient U: acrylic dome solid polycarbonate dome layered sheets / insulated solid cover glazing compliant with B ROOF (t1) classification The choice of control types depending on the project requirements: smoke exhaust: pneumatic, electric (24V-) ventilation: electric 230V~ Also available as smoke vents with daily ventilation and as only ventilation flaps, skylights or roof access hatches mcr PROLIGHT single leaf smoke vents of C type with roof access feature available dimensions: C 100 x 100 cm A wide range of leaf fillings: acrylic dome solid polycarbonate dome insulated solid cover glazing compliant with B ROOF (t1) classification Electric system of smoke exhaust and ventilation control (24V-)

mcr PROLIGHT SMOKE EXHAUST VENTS type DVP Double leaf vents with upright base Size range (roof opening) 120 x 250 cm 300 x 300 cm smoke exhausting: pneumatic, electric (24V-) ventilation: electric 230V~ AERODYNAMICAL ACTIVE AREA DVP type smoke vents can reach the max. aerodynamical active area of 6.6 m² with the application of elements increasing the active area (such as wind and inlet deflectors ) CONSTRUCTION OPTIONS A whole range of smoke exhaust vents types and optional elements to match the offer to the customer requirements Leaf filling that affects the heat transfer coefficient U: insulated solid cover glazing compliant with B ROOF (t1) classification Also available as smoke exhaust ventilation or daily ventilation flaps

mcr PROLIGHT SMOKE EXHAUST VENTS type NG-A Single leaf vents with slanting base Size range 110 x 110 cm 200 x 300 cm AERODYNAMICAL ACTIVE AREA Max. active surface that can be reached is 4.53 m² A wide range of leaf fillings that affect heat transfer coefficient U: acrylic dome solid polycarbonate dome insulated solid cover glazing compliant with B ROOF (t1) classification smoke exhaust: pneumatic, electric (24V-) ventilation: electric 230V~ CONSTRUCTION OPTIONS A whole range of possible options of vent constructions pursuant to custom-made philosophy to meet the customer demands Also available as smoke vents with daily ventilation, or only ventilation flaps, skylights or roof access hatches mcr PROLIGHT VENTILATION VENTS AND SKYLIGHTS type R Single leaf round ventilation flaps and skylights with upright base Available sizes Ø100 cm Ø180 cm ventilation: electric 230V~ Leaf filling that affects heat transfer coefficient U: acrylic dome solid polycarbonate dome insulated solid cover glazing compliant with B ROOF (t1) classification CONSTRUCTION OPTIONS A whole range of possible options of skylights pursuant to the idea of custom-made philosophy in order to meet the customer demands

SYSTEM FOR SMOKE AND HEAT VENTILATION The proper operation of smoke and heat ventilators in natural systems of smoke exhausting is possible due to devices controlling their opening and closing. The devices are the smoke exhaust and/or ventilation control systems. Types of control systems: electric (24V-) pneumatic electric (230V~) for daily ventilation function in pneumatic systems TYPICAL CONFIGURATION OF ELECTRIC SYSTEMS smoke vent smoke vent HDGs 2x2,5* HDGs 2x2,5* control panel mcr 9705 weather monitoring unit mcr P054 YnTKSY 1x2x0,8 YTKSY 1x2x0,8 YTKSY 2x2x0,8 YnTKSY 4x2x0,8 rain-wind sensor ventilation push button Fire Alarm Signalling System (optional) 230V~ optical smoke sensor manual alarm push button RPO-1 Fig. 1 Example of electric control system configuration for smoke and heat ventilators TYPICAL CONFIGURATION OF PNEUMATIC-ELECTRIC SYSTEMS smoke vent smoke vent Cu6 YTKSY 2x2x0,8 rain-wind sensor ventilation push button CO 2 alarm box with electromagnetical release 230V~ weather monitoring unit mcr P054 Fire Alarm Signalling System (optional) Fig. 2 Example of pneumatic control system configuration for smoke and heat ventilators with daily ventilation function 230V~

FIRE PROTECTION SYSTEMS smoke and heat exhaust systems fire ventilation systems fire protection of building structures NATURAL SMOKE AND HEAT EXHAUST SYSTEMS comprehensive solutions for smoke and heat exhausting protection of escape routs against smoke reduction of material losses caused by fire and smoke supply of light and fresh air to building interiors Mercor SA ul. Grzegorza z Sanoka 2 80-408 Gdańsk tel. +48 58 341 42 45 fax +48 58 341 39 85 mercor@mercor.com.pl www.mercor.com.pl