Firehawk Fire Alarms Battery Powered. Information, Installation and Maintenance

Similar documents
Firehawk Deaf Alert. Installation and Maintenance. Version 16/8/2017 New Features

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

169MHz Telecare Devices Carbon Monoxide Detector

Smoke Sensor w/escape Light. Do not use this sensor in hazardous (classified) locations or life safety applications.

1 Introducing Eve Smoke

Smoke Alarm User s Manual

169MHz Telecare Devices Heat Detector

Smoke Alarm User Manual

SMOKE ALARMS City of Grand Rapids Building Safety Division

Smoke Alarms and Carbon Monoxide Alarms

169MHz Telecare Devices Deaf Smoke Alarm Kit

169MHz Telecare Devices. Gas Detector

Wireless Interlink Smoke Alarm + 10 Year Life

WIRELESS PHOTOELECTRIC SMOKE ALARM

USER MANUAL 10 YEAR LIFE SMOKE ALARM

Smoke Alarm and Carbon Monoxide Alarm Installation

169MHz Telecare Devices Gas & Carbon Monoxide Detector

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

Smoke & Carbon Monoxide

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

230V~ SMOKE & HEAT ALARMS. with Rechargeable Battery Backup. Instruction Manual. Contact Us

LOW VOLTAGE PANEL SMOKE & HEAT ALARMS

230V~ SMOKE & HEAT ALARMS. with Alkaline Battery Backup. Instruction Manual. Contact Us

MFES READY Make your home fire safe. Home Smoke Alarms

Frequently Asked Smoke Alarm Questions

Heat Alarm User s Manual

SMOKE DETECTOR USERS GUIDE SMOKE DETECTOR SETUP GUIDE

ONLY WORKING SMOKE ALARMS SAVE LIVES

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

User guide. for smoke detector

USER INSTRUCTIONS MULTI-SENSOR FIRE ALARM 230V~ with Rechargeable Lithium Cell Back-up. Model: Ei2110

Ei3024 / 3016 / 3014 Alarms Instruction Manual

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

_V4:_ :28 AM Page 1. For model 29D,29HD. Photoelectric Smoke Alarm. User Guide

B16351-R0-Ei2100 SERIES-USE.qxd 18/9/08 3:47 PM Page 1 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up.

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

Ei160e Series 230V~ SMOKE & HEAT ALARMS. with Rechargeable Battery Backup. Instruction Manual. User Section

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

SI-610 / SO-610 User Manual. 10 Year Smoke Alarm Standard / Toast Proof with Smart Silence

Controlling condensation and Mould

PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions

Datasheet CALYPSO II R. Interlinkable smoke alarm device

HOME FIRE SAFETY. Reference Guide

EN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu

Condensation and Mould Advice for Tenants

Smoke Alarm User Manual

2-ZONE EASYFIT INTRUDER ALARM

Controlling Condensation and Mould

INSTALLATION AND OPERATION MANUAL

Smoke Alarm User s Guide

Battery Powered Smoke & Heat Alarms EIB600 Series

Photoelectric Smoke Alarm

RE214 Smoke Alarm Honeywell Compatible

Battery Powered Smoke & Heat Alarms Ei600 Series Instructions

A guide to. e Condensation. and how to reduce it

Connevans. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

10 YEAR LIFE SMOKE ALARM 10 YEAR LIFE TOAST PROOF SMOKE ALARM

HILLS Series LED Code Pad User Manual

Smoke Alarm User Guide

230V~ MULTI-SENSOR FIRE ALARM. with Rechargeable Lithium Cell Back-up. P/N B18397 Rev2. Ei2110e Series. Instruction Manual.

MODEL SS-901 EARLY WARNING PHOTOELECTRIC SMOKE & FIRE ALARM READ ALL INSTRUCTIONS

Fire precautions in dwellings

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

WIRELESS INTERLINK SMOKE ALARM + 10 YEAR LIFE WST-630

Melrose Fire Department

ESCAPE LIGHT SMOKE ALARM LSI-601 ESCAPE LIGHT TOAST PROOF SMOKE ALARM LSO-601

Bristol City Council Private Rented Sector Fire Safety Standards

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

_V1.qxd:_ :27 AM. Ionisation Sealed Smoke Alarm with Ten Year Lithium Battery & Hush. Manual. Model Q910

U.S. Fire Administration Fire Safety Checklist. for Older Adults. FA-221/July 2012

Smoke Alarm with RF Interlink User Guide

Comhshaol, Pobal agus Rialtas Áitiúil Environment, Community and Local Government. Fire safety at home

V-MUL-033(A0) RADIOLINK BASE

LSI-601 / LSO-601 User Manual. Smoke Alarm Standard / Toast Proof with Ultra Bright Escape Light

INSTRUCTION MANUAL PC255O

U S E R M A N U A L UBH1RF HEAT ALARM

D1265. User's Guide. Touchscreen Keypad

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Carbon Monoxide Alarms Smoke and Carbon Alarms Upgrade Requirements for Single and Two Family Dwellings

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

Welcome to. Welcome to Security and Peace of Mind CASTLE CARE TECH CARE TECH CARE TECH CARE TECH

INSTRUCTION MANUAL PC255O

Connevans. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Smoke Alarm Legislation

PHOTOELECTRONIC SMOKE DETECTOR

Carbon Monoxide Detector

THE TOWNSHIP OF CRANBURY

ADT Carbon Monoxide Alarm

Range Hoods. General Manual. For Models: IVN900X, IVN900N, IVCC900X, IVCG900, IVSG900

from the world leaders manufacturing over 35 million smoke, heat and carbon monoxide alarms every year

PLAN NOW!! Plan your escape today Your life may depend on it tomorrow HOME ESCAPE PLAN EXERCISE

For your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.

B15527-R3-3105RF-UC-ENG 14/10/08 9:35 AM Page 1. Radio Wireless Interconnect SMOKE ALARM

OPERATORS MANUAL RESIDENTIAL FIRE PANEL MODEL RFP12/18

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

2-ZONE EASYFIT INTRUDER ALARM

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

TEXAS A&M UNIVERSITY EMERGENCY MANAGEMENT. Home Safety. Smoke Alarms

quality european heating appliances

Transcription:

Firehawk Fire Alarms Battery Powered Information, Installation and Maintenance

FHB10 Smoke Alarm FHH10i Heat Alarm

Sounder FHB10 / 10i Smoke Alarm FHH10i Heat Alarm

Red LED FHB10 / 10i Smoke Alarm FHH10i Heat Alarm

Heat Sensor FHB10 / 10i Smoke Alarm FHH10i Heat Alarm

Large Test Button FHB10 / 10i Smoke Alarm FHH10i Heat Alarm

FHB10 Product and Contact Details

User Manual The overriding instruction is to ALWAYS follow the manufacturers guidance. ALWAYS read the ENTIRE handbook and keep it in a safe place where you can find it!! ALWAYS make sure you understand the lights and sounds.

Light and Sounds Power = Brief Red flash every minute followed by a Single beep after 10 secs if the battery is weak Alarm = Repeating Red flashing light twice every second + a series of 3 beeps every 4 seconds Alarm Silence = Brief Red flash every 10 Seconds Test = Repeating Red flashing light twice every second + a series of 3 beeps Fault = Double Bleep every minute Test Button Jammed = Single beep every 11 seconds

Alarm Silence An alarm sound can be silenced (Hushed, Paused etc) by pressing the test button during an alarm Pressing the test button when the full alarm is sounding will silence the alarm for 10 minutes. For safety reasons it cannot be selected in advance.

Silence Low Battery Warning Low battery warnings generally start at night due to the most significant temperature changes that occur and can affect battery power. (not necessarily off load voltage) The FHB10 has a Low Battery Silence Feature. Pressing the test button when the Low Battery Warning system is activated will silence the warning for 10 hours. Have a good nights sleep and change the alarm the following day. For safety reasons it cannot be selected in advance.

FHB10 Smoke Alarm Location Correct location is imperative if nuisance alarms are to be avoided Do NOT place in a draft. Do NOT place near bathrooms and showers Do NOT place in kitchens - use heat alarms there KEEP AWAY from vents or extractor fans Do NOT place directly above heaters, radiators or in front of air conditioning units Do NOT place in insect infested areas (attics, garages etc) - use heat alarms there KEEP 300mm AWAY from lights that generate heat. (Tungsten and low voltage bulbs) KEEP AWAY from objects that could divert or prevent smoke from reaching them, ie beams and other ceiling features. Remember: Heavy smoking in a poorly ventilated room produces DETECTABLE SMOKE and contaminates the alarm!!

FHH10i Heat Alarm Location Remember, heat alarms need a fire to activate, flames WILL be present. Do NOT install on walls Do NOT use in escape routes ALWAYS interlink to smoke alarms Do NOT use in lounges, bedrooms and separate dining rooms where smoke alarms are best Avoid use in areas where children, the elderly and disabled are normally present Designed for kitchens, garages, cellars, attics where steam, vapours, dust, and cobwebs may cause nuisance alarms from smoke alarms Keep 300mm AWAY from lights and appliances that generate heat. (Tungsten and low voltage bulbs) (Sensor temperature range 54 65 deg C ) KEEP AWAY from objects that could divert or prevent smoke and heat from reaching them, ie beams and other ceiling features. Keep away from extractor fans

Fixing to Ceilings Adaptor Plates

Fixing to Ceilings Double-Sided Sticky Pad Adhesive Plugs and Screws

Assembly to Mounting Plate Bring together. and twist to lock Twist

Removing from Ceilings Security Tag Press here and twist alarm anti-clock to release

Fire Alarms End User Maintenance REMEMBER - The overriding instruction is to ALWAYS follow the manufacturers guidance. Test the alarm once a week to ensure it is still operating ONLY use the test button. Do NOT use smoke or flame. It is dangerous, will contaminate the alarm and give misleading results If you must use canned smoke follow the manufacturers instructions. Vacuum the alarm to keep the vents clear of dust and insects Every six months clean the alarm with a damp cloth (do not use spray or chemical cleaners and polishes) In the event of a problem, contact our helpline on:- 0800 008 6568

Smoke and Heat Alarms- Trouble Shooting Be sure which alarm has been the problem, upstairs, downstairs, heat or smoke. Are the alarms interlinked? - If so check which one has a fast flashing red light during an alarm that s the one that has set the system off. Where is it installed? (refer to Do nots.. list in manual and earlier). If it is in a poor location this might be causing nuisance alarms. What is the alarm doing? ie single or double beeps, nuisance alarms etc etc Was the occupier cooking, cleaning, dusting, using aerosol spays etc etc? if so these may have caused the alarm to sound due to contamination. Has there been any decorating or building work recently? if so this may have contaminated the alarm and caused nuisance alarms Has there been outside fires, bonfires, chimneas, fire pits etc etc? if so, the smoke may have got into the property via doors, windows and vents.

Firehawk Fire Alarms Martin Ling. MSc, Cert Ed, MIFireE Technical Manager Fireblitz Extinguisher Ltd