IAQ_100 C Package

Similar documents
3SP_H2S_50 Package

3 3SP_O3_5 C Package

Frequently Asked Questions

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Toxic Gas Detection. Model F12. Toxic Gas Detection

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

SIL 2. Ultima X Series Gas Monitors CERTIFIED

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

APPLICATION NOTES for LED DISPLAYs

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

ESD500. ESD500 Combustible / Toxic Gas Detector

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

IR25 Dual Gas Series Datasheet

The MiCS-6814 is a compact MOS sensor with three fully independent sensing elements on one package.

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

CMF, CMX & CMA series

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

The MiCS-4514 is a compact MOS sensor with two fully independent sensing elements on one package.

ESD3000 ESD200 Combustible / Toxic Gas Detector

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

The MiCS-6814 is a compact MOS sensor with three fully independent sensing elements on one package.

IR15 Dual Gas Series Datasheet

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS

APPLICATION DATA SHEET

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

ALTAIR 5X Multigas Detector Product Specification

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Sieger Apex. Flexibility that meets your requirements

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

IR1 Single Gas Series Datasheet

Application Notes For LED Displays

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

SBS-H2 Hydrogen Gas Detector Kit

portable gas analyser

MICROpeL 75 Combustible Gas Sensor Part Number: PM

OLC(T) 100 FIXED GAS DETECTOR

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

The MiCS-5524 is a compact MOS sensor.

gas monitoring system

P R O D U C T D ATA S H E E T

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

The MiCS-5524 is a compact MOS sensor.

Warranty Registration

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Reverse Package Infrared LED IR25-21C/TR8

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Lamp Supply (Recommended)

EMI Filter (Data Line) TRIGON COMPONENTS. Dimensions Table (mm)

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Model D12. Digital Gas Transmitter

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Manufacturing Notes for RFPA2189

IGD.CO.UK

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

FEATURES ORDERING CODE EMCP C 100 N T (1) (2) (3) (4) (5) (6) (7) SMT Multilayer EMI Filter (Power Line) TRIGON COMPONENTS

SAFESITE Multi-Threat Detection System

Chapter 9: The basics of air preparation

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

Carbon Monoxide CO Transmitter ADT-X3-1110

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

Thermo Scientific Model 1160 Principle of Operation

Series 9000 Total Hydrocarbon Analyzer

Micro III (Models G203, G203S, and G213) Operation Manual

RFFM6403. Manufacturing Notes. Table of Contents

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

MICRO III (G202 / G202s / G212) Single Gas Detector

E1000 Portable gas detector

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Model D12-IR. Digital Gas Transmitter...

Selecting Gas Detectors for Confined Space Entries

portable gas analyser

Manufacturing Notes for RFPA2016

Inverted Through Board Surface

Preliminary specification

Transcription:

15x15 Indoor Air Quality Sensor 100 ppm C Package 110-802 DESCRIPTION SPEC Sensors IAQ_100 is a Screen Printed ElectroChemical sensor component specifically designed for the broad detection of gases associated with poor air quality: sulfides, alcohols, ammonia, odorous gases, and Carbon Monoxide. BENEFITS Zero Power Sensor o Sensor Circuit - < 10 uw max Cold operation - No Heating required Rugged Design- Not poisoned by sulfides, chlorides, NH3 Stable Response Not affected by humidity, CO2, N2, Ar, most saturated hydrocarbons, hexane Small Size& Low Profile - 20x20x3 mm Sensitive - In the ppm range Easy to Use - Linear Response Long Life - 10 years expected life Fast Response - < 20 seconds ROHS Compliant APPLICATIONS Bad Air Quality Detection Indoor Air Monitor Air Purifier Controls Weather Stations Internet of Things Smart Homes Early Fire Detection Leak Detection HVAC Ventilation Control

SPECIFICATIONS Measurement Range Response Time to 90% Sensitivity Expected Operating Life Operating Temperature Range Operating Humidity non-condensing Power Consumption Zero Drift (Over Temperature Range) Lower Detection Limit 0 to 100 ppm (calibrated as CO equivalents) < 20 seconds typical 12 +/- 3 na/ppm (CO equivalents) > 5 years (10 years @ 23+/-3C; 40+/-10% RH) -10 to 40 C (0 to 40 C continuous) 0 to 100% RH (15 to 95% continuous) < 50 uw circuit & ambient gas dependent +/- 2 ppm (CO equivalents) 0.1 ppm CO (depends on the gas & electronics) CROSS SENSITIVITY This sensor exhibits sensitivity to a wide range of gases. The following table lists the relative response of common gases. Gas ppm Typical Response (as ppm CO) Carbon Monoxide 100 100 Hydrogen Sulfide 100 370 Ozone 100-70 Nitrogen Dioxide 100-50 Sulfur Dioxide 100 70 Ethanol 100 140 Nitric Oxide (NO) 100 80 Chlorine 100-50 n-heptane 100 0 Ammonia 100 1 Methane 100 0 Saturated Hydrocarbons 100 0

IMPORTANT PRECAUTIONS All sensor designs are made for air monitoring @ 1 atm +/- 0.2 atm. Because applications of use and device implementation are outside our control, SPEC Sensors cannot guarantee performance in a given device or application, and disclaims any and all liability therefore. Customers should test under their own conditions to ensure the sensors are suitable for their requirements. Contact the factory to discuss specific concerns that might damage the sensor performance or life. Condensation and Water (1) Salt Water Contamination (1) High Temperature Operation (> 70C) for more than 1 month Low Humidity Operation (< 15% RH) for more than 3 months High Bias voltage Highly contaminated air over a prolonged period High levels of particles or soot (unless proper filtering is provided) (1) Use of porous PTFE membrane or filter cap may address this concern) MARKING INFORMATION All gas sensors are tested and marked at the SPEC Sensors factory. Sensors include a label with an alphanumeric code and a two-dimensional bar code. The codes include the information indicated in the table below.

DIMENSIONS PCB LAYOUT GUIDELINES

SENSOR STORAGE, HANDLING AND SOLDERING This information embodies various general recommendations concerning the storage, handling, and manual soldering conditions for SPEC SENSORS CSPEC Modules. It is only applicable for modules guaranteed by SPEC SENSORS stated in SPEC SENSORS Sensor Specification Sheet. Moreover, SPEC SENSORS' modules are NOT warranted and should NOT be used in high temperature soldering (reflow) or pre-tinning baths. Sensor & Module Handling Handle sensors with care. Take precautions, including but not limited to the following: A. DO NOT apply excessive pressure to the top or bottom of the sensor module. B. Whenever possible, handle or make contact with the sensor module from the sides of the PCB or substrate. C. Light vacuum pressure is possible during handling, DO NOT apply vacuum over gas sensor port. D. If the sealed sensor package is opened, DO NOT re-seal using vacuum or nitrogen gas. DO NOT reseal with desiccant. E. DO NOT obstruct the gas sensor port by making direct contact with any tape, apparatus, weights, etc. F. DO NOT use silicone or other conformal coatings around the sensor or gas port-holes. G. Operators are requested to wear powder free antistatic gloves. Manufacturing Assembly Floor Environment SPEC SENSORS recommends that the manufacturing assembly floor environment be maintained at controlled conditions: A. Temperature: 18-26 C B. Relative Humidity: 40 to 60% C. Pressure: 1.0 ± 0.2 atm Sensor & Module Storage Conditions The shelf life for sealed, packaged components is 12 months from the pack seal date, when stored in the factorysealed bag under the following conditions: A. Temperature: 5 to 25 C B. Relative Humidity: 20 to 80% C. Pressure: 1.0 ± 0.2 atm D. Storage Time: 12 months When moving from Storage Conditions to the Manufacturing Assembly Floor Environment, the sensors should be allowed to equilibrate at the new conditions for at least 24 hours prior to manufacturing. Module Attach Soldering Process Hand solder only. Keep the soldering iron or solder process tool away from the sensor. The sensor should not see pre-heat temperatures above 70 C. There have been suggested cases where a heat sink cover over the sensor may be applicable to protect the sensor during processing. No Application notes to this approach available. Only to be used as reference only. A. DO NOT heat sensor above 70 C B. Hand or peripheral process type approach C. Use solder wire alloy with the lowest possible eutectic temperature D. Use lowest possible soldering iron temperature E. Contact the host board with the soldering iron at a 45 angle on the solder pad F. Keep the soldering iron away from the top and bottom of the sensor module G. DO NOT place in reflow, wave or IR reflow type processes H. DO NOT place mounted board In a wash