Self-Contained Reverse Cycle Air Conditioners

Similar documents
Self-Contained & Split System Reverse Cycle Air Conditioners Models

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Self-Contained & Split System Reverse Cycle Air Conditioners SAB Self-Contained Units, CAB Condensers and DEAH Air Handlers

Indoor Air Handlers with Compressors MVS and MVW

Reverse Cycle Chiller Models CHA24, 36, 48 & 60

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

General Description. Operation

Wall Mounted Air Conditioners with Gas Heat Models AVGA

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Owner s and Installation Manual

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Hazardous Location Certified

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

MACH N-407 Heat Pump Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CR330 Owner s Manual

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Portable Vertical Air-Conditioning and Heating Systems

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Installation & Service Manual

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

RGE 13 A T - 1 A

10EER 7.5 Ton Vertical Wall Mount Air Conditioners Model AVHDA90 (Dual Compressor)

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

GUIDE SPECIFICATIONS AQUARIUS ii

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

2 shp 13 lc 1 36 t - 1 a

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

General Description. Safety Listed

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Q-TEC QC-Series Chilled Water Air Conditioner

13 GEP A L P - 1 A

MERIT SERIES Up Flow / Horizontal

AQUASNAP JUNIOR 30RHV

Condensing Units & Air Handlers

TECHNICAL SPECIFICATIONS

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Incremental Comfort Conditioners

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

MAC-120HE-03 Air-Cooled Chiller

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Q-Tec TM QC-Series Chilled Water Air Conditioner

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

General Description. Safety Listed

GUIDE SPECIFICATIONS AQUARIUS ii

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

PACKAGE AIR CONDITIONER

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

WCH5**4. Product Specifications

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MERIT Series R-410A - Upflow / Horizontal

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Condensing Units CUS 15-60

MERIT Series R-410A - Upflow / Horizontal

GREEN REFRIGERANT R-410A

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Installation and Operation Manual

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Concealed Ducted Split Series R-407C MBH

Advance Release September 2009

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

Kramersaver Air Cooled Condensing Units

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Transcription:

Self-Contained Reverse Cycle Air Conditioners Models MA 07-10-12-16-24 General Description Marvair's water source self-contained reverse cycle air conditioners are designed for use in either fresh or salt water. These units are built in capacities of 7,000; 10,000; 12,000; 16,000; and 24,000 TUH. The self-contained units are complete packaged units, factory charged and wired. A Marvair Marine first - a universal control board for all products - makes replacement quicker and easier and reduces the stocking requirements of service centers. R-410A Refrigerant MA16RC Less Watts: High efficiency Tecumseh and Copeland compressors More heat transfer with the cupronickel, eight volute, multi-lead inner tube. The convolutions increase heat transfer and refrigerant turbulence further enhancing the thermal performance, while inhibiting the accumulation of deposits in the water tubing. Powerful, backward inclined impeller moves the conditioned air effortlessly through duct. More Air Flow with Marvair s Unique ox lower : Three duct outlets eliminate the need to rotate the blower, saving installation time. No air distribution box required on the unit. Two to three da quieter than conventional centrifugal blowers. Less Space Our Most Compact Unit Stainless steel condensate pan no flimsy condensate connections. aked polyester coil rated to 1,000 hours in salt spray test. Rolled and embossed base pan adds structural support to all components Units are available for operation on 115V, 60 Hz; 208/230V, 60 Hz and 220/240V, 50 Hz. The units are built using R410A refrigerant. R410A is environmentally friendly, non-ozone depleting and accepted for use throughout the European Community. The reverse cycle air conditioners feature rotary and scroll compressors with a suction line accumulator and high and low refrigerant pressure switches. The coaxial tube-intube condenser is constructed of corrosion resistant cupronickel water tubing and copper refrigerant tubing. To ensure years of dependable performance, the units feature: A stainless steel base pan with multiple condensate drain openings allows the rapid disposal of condensate. The base pan is embossed to add rigidity and to keep the components out of the condensate. An insulated pad minimizes movement and sound. Structural supports, blower housing and control box constructed of superior corrosion resistant aluminum. The aluminum is primed and then a white heat cured polyester finish is applied for the optimum in durability and aesthetics. 1 MA Self self Contained contained PDS 1/2011

A five foot long (151 cm), heavy duty multiwire cable harness facilitates the remote mounting of the control box. This complete cable assembly seals all the wires into the harness to minimize the chance of corrosion. The evaporator coil is constructed of lanced fins and rifled copper tubing for optimum heat transfer. The coil has a baked polyester enamel finish - no paint - and is rated to 1,000 hours when tested to ASTM 117. A compact, motorized impeller type blower moves the conditioned air quietly and efficiently through duct work. ackward curved, corrosion resistant centrifugal fans feature extremely long blades for high efficiency and low noise. Maintenance free ball bearings never need oiling. All units are built to the requirements of UL standard 484, 7th Edition. Marvair is an ISO 9001-2008 registered company. All self contained and split systems units (unless designated otherwise) meet applicable AYC and US Coast Guard regulations, CE directives, and all applicable Air Conditioning, Heating and Refrigeration standards. Installation Installation of units is simplified with a readily accessible terminal strip for both the power and control (low voltage) wiring. The control box is located on the side of the self contained units. However, the control box can be easily mounted on the opposite side or remotely mounted on a bulkhead. A five foot (151 cm) multiwire cable harness provides a durable and quick electrical connection between the unit and the control box. Condensate line ports (5/8 nylon tube) on both ends and both sides of the base pan facilitate the drain line connections. Factory provided hold-down clamps are included. Thermostats All units can be controlled by either the o-touch, o-led or the MachAir I thermostat/controller. The o-touch, o-led and the MachAir I thermostat/controller display shows whether the unit is in the heating or cooling or fan only or dehumidification mode, set point temperature ( F or C), cabin temperature ( F or C) and fan indicator. The cooling or heating can be selected manually or the Auto mode selects whichever is required automatically. The fan speed can be controlled automatically or manually. Includes wall mounted controller/display. See the Product Data Sheet for complete information on the thermostat/controllers. Accessories Accessories are required and ordered separately. Sea Water Pump Kit. Air duct, supply grille(s) and return grille. Plumbing fittings. Thermostat/controller. Model Identification - Self-Contained Units M A RC M = Marine Refrigerant A = R410A Controller = Electronic Control oard Nominal Capacity 07 = 7,000 TUH 10 = 10,000 TUH 12 = 12,000 TUH 16 = 16,000 TUH 24 = 24,000 TUH System Type RC = Reverse Cycle Voltage A = 208/230V, 1ø, 60 Hz = 115V, 1ø, 60 Hz W = 220/240V, 1ø, 50 Hz Electronic Thermostat/ Controller M2 = o-touch or o-led oard MA self contained PDS 1/2011 2

Water Flow Chart Minimum Water Flow* for Reverse Cycle Systems Model (TUH) Minimum Water Flow at the Unit 7,000 2.0 GPM / 7.6 LPM 10,000 2.9 GPM / 11.0 LPM 12,000 3.5 GPM / 13.3 LPM 16,000 4.7 GPM / 17.8 LPM 24,000 7.0 GPM / 26.5 LPM * ased upon 85 F (29.5 C) inlet water measured at the inlet of the unit. Air Flow and Grille Chart Model Number Nominal Air Flow Minimum Opening for Return Air Grille Minimum Opening for Supply Air Grille(s) Minimum Hose Size a Marvair P/N of lower ox to Oval Hose Adapter Qty of Oval Hose Adapters Outside Dimensions of Hose Adapter CFM m 3 /hr In 2 cm 2 In 2 cm 2 In cm Inches cm MA07RCA, 200 340 5 12.7 91565 b 2 6 x 2½ 15.2 x 6.4 RC 225 382 7 17.8 91567 1 8¾ x 3-3/8 22.2 x 8.6 100 645 40 260 MA07RCW 215 365 5 12.7 91565b 2 6 x 2½ 15.2 x 6.4 240 408 7 17.8 91567 1 8¾ x 3-3/8 22.2 x 8.6 MA10RCA, 215 365 6 15.2 91566 b 2 7½ x 2¾ 19.1 x 7 RC 215 365 7 17.8 91567 1 8¾ x 3-3/8 22.2 x 8.6 100 645 60 390 MA10RCW 190 323 6 15.2 91566b 2 7½ x 2¾ 19.1 x 7 190 323 7 17.8 91567 1 8¾ x 3-3/8 22.2 x 8.6 MA12RCA, 325 552 6 15.2 91566 b 2 7½ x 2¾ 19.1 x 7 RC 310 527 7 17.8 91567 1 8¾ x 3-3/8 22.2 x 8.6 140 900 70 450 MA12RCW 260 442 6 15.2 91566b 2 7½ x 2¾ 19.1 x 7 215 365 7 17.8 91567 1 8¾ x 3-3/8 22.2 x 8.6 MA16RCA, 320 544 7 17.8 91567 b 2 8¾ x 3-3/8 22.2 x 8.6 RC 305 518 8 20.3 91568 1 10 x 4 25.4 x 10.2 168 1110 84 540 MA16RCW 275 467 7 17.8 91567b 2 8¾ x 3-3/8 22.2 x 8.6 290 493 8 20.3 91568 1 10 x 4 25.4 x 10.2 700 1189 8 20.3 91568 b 2 MA24RCA 525 892 8 20.3 91568 1 240 1550 192 1240 MA24RCW 625 1062 8 20.3 91568b 2 465 790 8 20.3 91568 1 10 x 4 25.4 x 10.2 The blower box on all MA units has openings for three duct adapters. For optimum performance and air flow, two duct adapters should be used. a Use larger size hose if hose run is greater than 10 ft. (3 meters). b Two oval hose adapters are shipped with each MA unit. 3 MA self contained PDS 1/2011

Performance & Electrical Data for MA self-contained units, 208-230v, 60 Hz. Model Number Nominal Capacity (TUH) Volts / Ph / Hz LRA 1 KVA 2 Unit Run Amps Cooling 3 Heating 4 MCA 5 MFS 6 MA07RCA 7,000 208-230/1/60 22.2 0.9 2.97 3.84 5.1 10 MA10RCA 10,000 208-230/1/60 22.2 1.0 3.34 4.49 5.9 10 MA12RCA 12,000 208-230/1/60 32.5 1.2 3.89 5.01 6.8 10 MA16RCA 16,000 208-230/1/60 29.0 1.4 4.58 6.05 8.3 10 MA24RCA 24,000 208-230/1/60 58.3 2.3 6.96 9.96 17.7 25 1 LRA = Locked Rotor amps (compressor only) 2 KVA = Kilo volt amps 3 Cool = 45 F evaporator and 100 F condenser 4 Heat = 45 F evaporator and 130 F condenser. 5 MCA = Minimum Circuit Ampacity (Wire size amps) 6 MFS = Maximum Fuse or HACR breaker size Performance & Electrical Data for MA self-contained units, 115v, 60 Hz. Model Number Nominal Capacity (TUH) Volts / Ph / Hz LRA 1 KVA 2 Unit Run Amps Cooling 3 Heating 4 MCA 5 MFS 6 MA07RC 7,000 115/1/60 45.6 0.91 6.26 7.95 10.4 15 MA10RC 10,000 115/1/60 45.6 1.07 7.01 9.27 12.0 20 MA12RC 12,000 115/1/60 63.0 1.24 8.60 10.80 13.3 20 MA16RC 16,000 115/1/60 63.0 1.62 11.50 14.09 14.6 20 1 LRA = Locked Rotor amps (compressor only) 2 KVA = Kilo volt amps 3 Cool = 45 F evaporator and 100 F condenser 4 Heat = 45 F evaporator and 130 F condenser. 5 MCA = Minimum Circuit Ampacity (Wire size amps) 6 MFS = Maximum Fuse or HACR breaker size Performance & Electrical Data for MA self-contained units, 220-240v. 50 Hz. Model Number Nominal Capacity (TUH) Volts / Ph / Hz LRA 1 KVA 2 Unit Run Amps Cooling 3 Heating 4 MCA 5 MFS 6 MA07RCW 7,000 220-240/1/50 18.8 0.9 2.80 3.74 5.2 10 MA10RCW 10,000 220-240/1/50 21.0 1.0 3.20 4.22 5.2 10 MA12RCW 12,000 220-240/1/50 21.0 1.0 3.20 4.22 5.2 10 MA16RCW 16,000 220-240/1/50 24.5 1.4 4.39 5.89 6.4 10 MA24RCW 24,000 220-240/1/50 61.0 2.8 8.26 11.86 16.5 25 1 LRA = Locked Rotor amps (compressor only) 2 KVA = Kilo volt amps 3 Cool = 45 F evaporator and 100 F condenser 4 Heat = 45 F evaporator and 130 F condenser. 5 MCA = Minimum Circuit Ampacity (Wire size amps) 6 MFS = Maximum Fuse or HACR breaker size MA self contained PDS 1/2011 4

Dimensional Data - Self-Contained Models 07-10-12-16 (inches & mm) L M K H J G F N Oval Hose Ring C D E A A C D E F G H I J K L M N Marvair P/N Description MA07 In 24 13 5/8 4 1/2 11 5 1/2 2 7/8 4 11/16 6 2.6 5 1/2 2.66 7 5/9 2 5/8 6 1/8 91565 5 OVAL RING MM 610 346 114 279 140 73 119 152 66 140 68 191 67 156 MA10 In 24 13 5/8 4 1/2 11 5 1/2 2 7/8 4 11/16 6 2 5/8 5 1/2 2 11/16 7 5/9 3 7 1/4 91566 6 OVAL RING MM 610 346 114 279 140 73 119 152 67 140 68 191 76 184 MA12 In 25 13 7/8 4 1/2 11 5 1/2 2 7/8 4 11/16 6 2 5/8 5 1/2 2 11/16 7 5/9 3 7 1/4 91566 6 OVAL RING MM 635 352 114 279 140 73 119 152 67 140 68 191 76 184 MA16 In 25 13 7/8 4 1/2 11 5 1/2 2 7/8 4 11/16 6 2 5/8 5 1/2 2 11/16 7 5/9 3 7/16 8 3/4 91567 7 OVAL RING MM 635 352 114 279 140 73 119 152 67 140 68 191 87 222 I 5 MA self contained PDS 1/2011

Dimensional Data - Self-Contained Model 24 (inches & mm) CONTROL OX 5-7/8 [149] 2-11/16 [68] A MARVAIR A 10-1/8 [256] LEFT SIDE VIEW FRONT VIEW USHING SCHEDULE MK QTY ID 15/16 (25 mm) 11/16 (20 mm) RIGHT SIDE VIEW RIGHT HAND UNIT FILTER TOP VIEW CONTROL OX RIGHT SIDE VIEW 10" x 4 " (254mm x 102 mm) OD OVAL ADAPTER (TYP.) COIL LOWER OX COMPRESSOR WRAP COIL 16-13/16 [427] 18 [457] 10" x 4 " (254mm x 102 mm) OD OVAL ADAPTER (TYP.) 29-3/16 [741] ACK VIEW LEFT SIDE VIEW WATER OUT 5/8" O.D. (15.8 MM) 14-9/16 [370] 16-13/16 [427] MARVAIR 1 [26] CONDENSATE FITTING.563 O.D. (14.2 MM) (TYP.) For 5/8" (14.2mm) condensate tubing CONTROL OX WATER IN 5/8" O.D. (15.8 MM) 14 [356] CONTROL OX WEIGHT: 111 LS / 50 KG There are two conditioned air outlet openings, one on the top and one on the right side. Each opening is a 9-7/8" x 4" (251mm x 102mm) oval opening. An oval adapter, Marvair part number 91568, should be used as a transition to duct on each opening. This adapter has an outside diameter of 10" x 4" ( 254 mm x 102 mm). For optimum performance, both openings must be used. Insufficient air flow can cause ice to form on the evaporator coil in the cooling mode and premature activation of the circuit breaker in the heating mode. MA self contained PDS 1/2011 6

Notes 7 MA self contained PDS 1/2011

Notes Please consult the Marvair website at www.marvair.com for the latest product literature. Complete installation instructions are in the SeaMach Installation and Service Manual. Detailed dimensional data is available upon request. A complete warranty statement can be found in each product s Owner's Manual, on our website or by contacting Marvair at 229-273-3636. As part of the Marvair continuous improvement program, specifications are subject to change without notice. P.O. ox 400 Cordele, Georgia 31010 156 Seedling Drive Cordele, Georgia 31015 Ph: 229-273-3636 Fax: 229-273-5154 Email: marvair@airxcel.com www.marvair.com MA self contained PDS 1/2011 8 Marvair Marine UK Unit 6 enridge Park Holyrood Close Poole, Dorset H17 7D. +44 1202 606405 www.marvair.co.uk Marvair, Division of AIRXCEL, Inc. 1/2011