EVERY DAY IN FIRST CLASS

Similar documents
EVERY DAY IN FIRST CLASS

EVERY DAY IN FIRST CLASS

5580 EXPLORER DRIVE EXCELLENT BRANDING OPPORTUNITY WITH HIGHWAY 401 SIGNAGE MISSISSAUGA, ONTARIO AEROCENTRESOFFICES.COM

EXCELLENT BRANDING OPPORTUNITY WITH HIGHWAY 401 SIGNAGE BUILDING CLASS: FLOORS (#): 4 TOTAL SIZE: PARKING TYPE:

5 dock doors, 2 grade doors. Sprinklers throughout

BULLII I The Greenest Office Building in the World

University Office Center - Phase I

$2,400,000. Fine Parts/Electronic Production Facility FOR SALE: FOR SALE 955 Green Valley Road, London ON

LEED GOLD Certified Office Building

Retail Box For Sublease

25 A&B Vreeland Road Florham Park, N.J.

HORIZON PARK BUSINESS CENTER, Phase 2

FOR LEASE ROCKWOOD OFFICE PARK

3424 Chicago Drive Hudsonville, MI 49426

FENLEY OFFICE PARK B US Highway 42, Louisville, Kentucky

TEN MILE & FRANKLIN LAND 39± ACRES 2954 WEST FRANKLIN ROAD MERIDIAN, ID

COVIDIEN SENECA, SOUTH CAROLINA

±12,800 SF TWO STORY BUILDING

FOR LEASE > CREEKSIDE

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

Auto Dealership off I-295

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Facility Condition Assessment Summary Report. British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building

Highly efficient space with close to 1,000 seats and over 100 meeting spaces. True plug-n-play with high-end FF&E

Plot # R019A ± 74' ± 74' ± 65' Plot # R019A LEASE OUTLINE DRAWING GROSS LEASABLE AREA ± 4,631 S.F. DEMISING FRONT WIDTH DEPTH ± 13' ± 32' Lease Line

Fire Protection. A Health and Safety Guideline for Your Workplace. Introduction. Fire Prevention and Control. Workplace Assessment

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

Unit # E ± 1,200 SF Width ± 20' Depth ± 60'

100 COMMERCE DRIVE CHRISTIANA CORPORATE CENTER NEWARK, DE

2 Main Office Building BLDG-955A Building Purpose Building Area Administration offices. Training room 7,610 SF Inspection Date August 16, 2016 Inspect

Emerald Lake Corporate Centre

Washington Irving Elementary School

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information

Emerald Lake Corporate Centre

PLATTEVILLE MIDDLE SCHOOL

Paradise Marketplace. Unit # AOP +/- 1,600 SF +/- 12' +/- 11' +/- 8' 11'-7" +/- 85' +/- 74' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width.

Proposed Mechanical, Plumbing, and Electrical Systems For the LEDYARD POLICE DEPARTMENT LEDYARD, CT

Florence High School / Middle School Page 1 of 3 Florence, WI

TECHNICAL SPECIFICATIONS ANZ TOWER

Self-Storage/Commercial Development Site

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

TECHNICAL SPECIFICATIONS 167 CASTLEREAGH STREET

Request for Proposals (RFP) for: Columbia County Facilities Fire Detection and Security Improvements

Paradise Marketplace REAR FRONT. Unit # AOH +/- 1,700 SF +/- 20' +/- 85' +/- 85' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width. Depth

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

Motion Controlled Apartment Building Corridor Lighting

INITIAL FIRE SAFETY ASSESSMENT

Building Self-Inspection Program

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

FIRE SAFETY INSPECTION REPORT

George B Swift Elementary Specialty School

2233 Park Avenue. Property Features FOR LEASE > OFFICE 2233 PARK AVENUE, ORANGE PARK, FL ,200± SF AVAILABLE

LOCATION. By Taxi Taxis are readily available to and from 28 Hennessy Road. ACCESSIBILITY. Kowloon Tong

FIRE SAFETY INSPECTION REPORT

Oscar DePriest Elementary School

Francis M McKay Elementary School

Karrat Group City of Fountains City of Fountains Apartments City of Fountains

Vacant Building Loss Prevention Best Practices

Agustin Lara Elementary Academy

FIRE/SMOKE BARRIER FUNDAMENTALS

THOROUGHLY THOUGHT THROUGH & THROUGH

Public Health Fax: Web Site:

Design Architect s/applicant s Certification Of Threshold Criteria

1225 TUNNEL ROAD PERKASIE BOROUGH, BUCKS COUNTY, PA

Public. Mike Free Health. State of Alabama Department of

ENGINEERING REPORT - MECHANICAL / ELECTRICAL / PLUMBING

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

Unit # H ± 2,000 SF Width ± 25' Depth ± 80'

PLAN REVIEW SUBMITTAL GUIDE

ELECTRICAL Seminar. B A L A Consulting Engineers, Inc. Edward J. Lynch, PE Vice President, Electrical Department Manager.

Electrical Information

Construction Method, Material Selection, Fire Prevention & Building Security System For Project 9a : Board 4 ; For Project 9b : Part 4

Ball Corporation 140,000 Square Feet on 27 Acres Birmingham, Alabama

Paramount Property Mgmt & Realty LLC MOVE-IN / MOVE-OUT CONDITION CHECKLIST

MOVE-IN / MOVE-OUT CONDITION

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

TO: FROM: to help us. generates. e support.

Edward Jenner Elementary Academy of the Arts

HVAC / Boilers / Hot Water. Expected Life Span. very rough estimates Condition/Issue Age. Athletics / Gyms

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

Charles W Earle Elementary School

ENGINEERING REPORT - MECHANICAL / ELECTRICAL / PLUMBING

INITIAL FIRE SAFETY ASSESSMENT

FOR SALE OR LEASE ±12,600 SQ. FT. AUTO/TRUCK SERVICE FACILITY

Beaufort County Community College. Maintenance and House Keeping Plan

INITIAL FIRE ASSESSMENT REPORT (FAR)

EXECUTIVE TOWER SOUTHCENTRE MACLEOD TRAIL SE BUILDING OVERVIEW FOR MORE INFORMATION CONTACT

Appendix B. Facilities Assessment Report

FIRE SAFETY INSPECTION REPORT

12680 HIGH BLUFF DR. SAN DIEGO, CA 92130

INITIAL FIRE ASSESSMENT REPORT (FAR)

Calmeca Academy of Fine Arts and Dual Language

PRIME RESTAURANT/RETAIL SPACE FOR LEASE

3. 21st Century Learning A. Districtwide Flexible Learning - Allowance for Flexible Furniture $600,000 Subtotal $600,000

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

BLUEPRINT FOR PERIMETER, PHYSICAL SECURITY AND ACCESS CONTROL AT ELDO LAKES EXT. 5 & 6

Smart Homes in. Rajya Sabha Co-operative Housing Society

Café DUSON- Overview

FIRE SAFETY INSPECTION REPORT

Transcription:

5600 EXPLORER DRIVE AEROCENTREOFFICES.COM EVERY DAY IN FIRST CLASS

EVERY DAY IN FIRST CLASS 5600 EXPLORER DRIVE SF AVAILABILTY ASKING RATE COMMENTS GROUND FLOOR SUITE 101 7,556 Immediate $17.50 Net Ground floor suite with double glass door entrance off main lobby. Ready for tenant improvements. 9`9 high ceilings. Access to one truck level door. GROUND FLOOR SUITE 102 3,630 Immediate $17.50 Net Ground floor finished model suite with double glass door entrance off main lobby. 9 9 high ceilings. Mix of private offices, large boardroom, open space and kitchenette/lunchroom. ADDITIONAL RENT REALITY TAXES: $4.92 PSF OPERARING COSTS: $10.10 PSF TENANT HYDRO COSTS: $1.30 PSF ADDITIONAL RENT: $16.32 PSF (2018) Spend every day in first-class at Aero-Centre, an award-winning office community offering many on-site amenities. AeroCentre s prime location offers branding opportunities with exposure to Highway 401 in the prestigious Airport Corporate Centre. Easy access to Highways 401, 427 and 403 and minutes away for Pearson International Airport. Located within walking distance or short drive to numerous amenities and adjacent to Max Ward Park.

5600 EXPLORER DRIVE BUILDING SPECIFICATIONS Number of Floors: 4 Total SF: 57,698 SF Year Built/Refurb: 1989 Typical Floor Plate: Parking: 15,400 SF 3.2/1,000 SF EXTERIOR The exterior of the building consists primarily of double glazed blue vision glass and single glazed blue spandrel panels set on aluminum framed curtain wall assembly. The roof is a two ply torch down bitumen roof with ballast. SUSTAINABILITY The building is BOMA BESt Gold certified and the recipient of the 2015 Race to Reduce Awards for Greatest Energy Reduction as well as Lowest Energy Use (under 250,000 sq.ft.). A risk management program run by RiskCheck Inc. provides Environmental, Health and Safety (EHS) Risk Management Service by correctly identifying, managing, and monitoring risks, and helping to establish the procedures to eliminate or control hazards. Monthly reports in addition to annual inspections provide updates on the status of current levels of statutory compliance plus a general summary of current and planned initiatives. TELECOMMUNICATIONS The building is equipped with Bell and Rogers communications fibre optics.

SECURITY After-hours access to the building is provided through pass cards and they are programmed for limited access to the building. There are three CCTV cameras, one located at each entrance of the building and one exterior camera facing the driveway, all backed up into a digital video recorder. MECHANICAL The building is ventilated by four cooled air handling units complete with DX coil. The units are located one per floor with the ground floor unit being larger. The units supply air to the variable air volume boxes throughout the building. The VAV boxes are complete with pneumatic controls. The building is equipped with an air compressor that provides compressed air to the pneumatic controls. The mechanical air distribution systems, consists of compartmental air handlers that provides ventilation and cooling to each of the 4 floors, a cooling tower, gas fired boilers with Siemens night set back controls for energy efficiency. Two atmospheric hot water boilers provide perimeter radiant heating to all floors. All washrooms are equipped with water efficient and hands-free faucets, soap dispensers and urinals. LIGHTING The building standard lighting is T8 and electronic ballast technology, LED lamps in lobby and LED exit lights. Interior lights are managed by a computerized lighting control system. Override switches allow tenants to turn lights on in various work areas should they require additional lighting outside of regular business hours. These fixtures will automatically turn off after the override has been activated within 2 hours for added energy conservation. All washroom lights are on motion sensors for energy conservation. ELECTRICAL The electrical power supply is provided from a transformer located on the ground floor in the electrical room providing 1200 amps and 347/600 volts of power. EMERGENCY GENERATOR/BACK UP POWER In the event of a power failure, emergency lighting will illuminate for a span of 30 minutes. The management office located in 5580 Explorer is et up with emergency generator power to allow the management team to maintain consistency and operations in the event of a power failure. FIRE LIFE SAFETY SYSTEMS The building is equipped with sprinklers and a standpipe system. There are typically two fire hose cabinets, with extinguishers, per floor. The Edwards fire alarm panel controls detection points throughout the building and is monitored 24/7. Smoke and heat detectors and pull stations are located throughout the building. ELEVATORS Two hydraulic elevators provide speed and convenience to all floors and include hands free communication to the emergency monitoring station. TENANT SERVICES Menkes uses Angus AnyWhere Tenant Service Request. This is a fully web enabled service management solution specifically designed for commercial real estate. Detailed service requests are submitted by tenants through the Menkes website and sent to the appropriate party for action. The real-time application interacts with handheld wireless messaging device to speed service delivery and ensure prompt service action. The management team reviews reports regularly to monitor the types and frequency of various service request.

5600 EXPLORER DRIVE SUITE 101 RENTABLE AREA = 7,556 SF ABOVE INFORMATION ESTABLISHED ACCORDING TO BOMA / ANSI Z65.1 1996 SUITE 102

EVERY DAY IN FIRST CLASS SUITE 102 RENTABLE AREA = 3,630 SF ABOVE INFORMATION ESTABLISHED ACCORDING TO BOMA / ANSI Z65.1 1996 FHC FHC ED IT CLOSET 109 SERVERY 106 RECEPTION/ WAITING 100 OPEN OFFICE 108 COATS 107 SUITE 102 COATS 101 PRIVATE OFFICE PRIVATE OFFICE 105 104 PRIVATE OFFICE BOARDROOM 103 102

AEROCENTREOFFICES.COM EVERY DAY IN FIRST CLASS CONTACT US: Domenic Galati* Senior Vice President +1 416 620 2834 domenic.galati@colliers.com Ron Jasinski* Senior Vice President +1 416 620 2801 ron.jasinksi@colliers.com Colliers International Toronto West 401 The West Mall, Suite 800 Toronto, ON M9C 5J5 +1 416 777 2200 www.collierscanada.com This document/email has been prepared by Colliers International for advertising and general information only. Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. Any interested party should undertake their own inquiries as to the accuracy of the information. Colliers International excludes unequivocally all inferred or implied terms, conditions and warranties arising out of this document and excludes all liability for loss and damages arising there from. This publication is the copyrighted property of Colliers International and /or its licensor(s). 2017. All rights reserved. This communication is not intended to cause or induce breach of an existing listing agreement. Colliers Macaulay Nicolls Inc.