INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Similar documents
SMOKE CONTROL - NEW DIRECTIONS

Underground carpark ventilation

Discover ebm-papst for buildings. Energy-efficient fans for a controlled room atmosphere.

Systemair product news - Fans NEWS

The Integrated. car park ventilation solution. JetVent Ultra Low-Height NOW AVAILABLE

GreenJet Transfer Fans

UNIJET CAR PARK VENTILATION SYSTEM

TUNNEL FANS STANDARD AND HOT SMOKE

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

Colt ventilation systems for car parks, loading bays and service areas

Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010

Car Park Ventilation 1

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

EHH SERIES DRAW THROUGH FAN COILS CFM

Domestic & Commercial Fans

Tailored air movement control solutions

ROOFMASTER STEF-HT ROOF FAN

Centrifugal Fans, Non-Overloading, Backward Inclined

LOWERING THE COST OF HIGH CEILINGS

EC, energy efficient building services

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

AXIAL & JET FANS FOR TUNNEL VENTILATION

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Tunnel Systems. Design & Supply Metro Axial Fans. Tunnel Axial Fans. Jet Fans.Fans for Escape Tunnel System Components. Engineering Support

Aspirating Gas Detection CFD Modelling Predicts Application Performance

JET FANS CAR PARK VENTILATION SYSTEMS F400 - F300 - F200. EN Powered smoke and heat exhaust ventilators for use in Construction Works

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Centrifugal Blower. Backward/Aerofoil Curved.

Tunnel Axial Flow Fan

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

Introduction to Fans. The Basics of Fan Principles and Terminology

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

KOMFORT EC DB Suspended heat recovery air handling units

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

GreenPark. GreenJet Throw Performance

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Myth & Reality of Basement Ventilation

SINGLE PHASE RANGE BD BD 19/19 M4 1/5 BD 19/19 M6 1

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Selecting the Correct Fan

Ventilation, Air- Conditioning and Refrigeration Industry

Modular Air Cooled Scroll Chillers

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

OXeN. Ductless ventilation with heat recovery.

ENERGY EFFICIENT RETROFITS. Date

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Double Skin Air Handling Units

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

PRODUCT RANGE: ROOFTOP PACKAGE

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Ducted inverter reverse cycle air conditioning

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

LOW STATIC HYDRONIC DUCTED UNIT

Discover ebm-papst in commercial kitchen equipment. Durable and reliable products for constant use.

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

LZT High efficiency air to water heat pumps with E.V.I. compressors

Commercial Evaporative Cooling

E-Wheel Backward Curved Centrifugal Fans

AC Backward Curved Motorized Impellers

ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Flexible and efficient: Close Climate Control for IT equipment

Cozy Hi Wall Inverter Air Conditioner

MECHANICAL SERVICES 101. Ian White

Centrifugal air heaters hot water or electrical supply

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Air distribution for clean rooms. Clever and flexible.

KITCHEN EXTRACTORS K Series

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Axial fans The right fan for every house

Case Study 1 Underground Car Park

NEW RANGE OF WARM AIR CURTAINS

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

SHIPWIDE VENTILATION BUYING GUIDE

Washer extractor. Features and benefits. Main options. Main specifications W4400H, W4600H 45/100 65/ / 54

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

LZA High efficiency air to water heat pumps with HP compressor

Water-cooled chillers with High Speed Centrifugal Compressors

Product Specifications. Vertical Floor Consoles By First Co.

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

Innovation for a Better & Greener Future

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

Smoke extract fan SMHA HATCH

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products

Transcription:

JAU /JCC/JVC Series Jet Fans - for car park ventilation INTRODUCTION Pacific HVAC Engineering is able to offer a complete solution in car park ventilation at a competitive price with in house developed EC jet impulse fans along with AC jet impulse fans. Car Park Ventilation Principles Jet fan systems are active systems offering a cost effective solution to ventilate and extract smoke and pollutants, for example Carbon Monoxide (CO), from car parks. This ductless ventilation system provides either normal ventilation or smoke extract in case of emergencies, or a combination of both. An efficient system requires good planning, starting with the physical dimensions of the cark park, considering the pattern of utilisation as well as peak loads. Ventilation rates are mostly based on an air exchange rate, or on a rate multiplied with the number of parking spaces. A Jet Fan system offers the ventilation on demand principle for car parks, depending on measurements by CO sensors. Jet Fans can be individually controlled, or grouped together in fire zones. In fire mode, after a pre-set standstill escape period, the jet fans will run at full speed to quickly and effectively clear smoke. Benefits The space saving design, compared to a standard duct based ventilation systems, offers a variety of benefits: It is possible to ventilate or extract smoke in particular sections of the car park. CO (carbon monoxide) and smoke sensors ensure that only fans in polluted areas are activated and the fans are switched into smoke extract mode immediately if a fire starts. No expensive, bulky and complex duct systems, making it an ideal solution for renovations. Car park design is more attractive. Improved air quality in car parks compared to conventional ducted systems. Optimum safety is provided in case of a fire in the car park. Rapid smoke extraction, smoke cooling, limited smoke spread, i.e. better smoke control. Jet Fan systems for smoke extract prevent costly consequential damages in case of a fire: the ceilings are subjected to less heat, and smoke is quickly removed from the building. More flexible in re-positioning when the parking area is redesigned. Energy saving in exhaust air fans due to reduced system resistance (no duct systems). Reduced installation and running costs. BCA And The Requirements of AS/NZS1668.2 The use of an appropriately designed Jet Fan system is deemed to meet the requirements of the Building Code of Australia (BCA) and comply with AS/NZS1668.2 provided there is evidence to support the efficacy of the installed system. Evidence of the system function and compliance is produced in the form of computer generated models (Computational Fluid Dynamics Analysis) simulating air flows within the structure.

JAU /JCC/JVC Series Jet Fans - for car park ventilation INTRODUCTION BCA And The Requirements of AS/NZS1668.2 (Continued) In order to perform a CFD analysis, it is essential to have a 3-D model of the building site, giving all openings, slab height, surface of the ceiling (flat or with drop beams, dimensioning of the drop beams, etc.) and all other details required to carry out a simulation. A CFD analysis is used to simulate the airflows, to ensure that the distribution of the air is sufficient to effectively ventilate the cark park under normal conditions as well as in emergency situations. The analysis references all aspects of the design of the structure and the emissions concentrations calculated for the intended usage loads of the building. The CFD report illustrates the number and placement of Jet Fans taking into account the building design and structural obstacles. Pacific HVAC Engineering is able to facilitate the preparation of CFD Reports on a project by project basis. Costing is quoted taking into account the scale as well as complexity of the project. Control Systems A control system is required, which is tailored to handle the requirements of the specific project for ventilating and smoke extraction. An effective control system saves energy by reducing the ventilation rate with the help of CO sensors, depending on the car park usage, increasing ventilation rate only in peak hours and operating the jet fans only selectively, according to demand. When used for smoke extract, the system has to work on a fire detection system (heat or smoke detection). In car parks with different levels, the system has to run the jet fans full speed on the fire level, and simultaneously switch off the fans in all other levels. The main exhaust air fans are switched to full speed. The control equipment regulates the main supply and/or exhaust fans together with the jet fans, both depending on the signals coming from the sensors. Note: Pacific HVAC Engineering work with control experts to facilitate system designs specific to your project needs. JAU - Series Axial Impulse Fans. JCC - Series Low Profile Centrifugal Impulse Fans. JVC25 EC Impulse Fans.

JAU Axial hi temp series jet fans Description JAU Series Jet Fans are axial impeller types with smoke spill certification to AS/NZS4429:1999. Range Three impeller sizes : 315mm, 350mm, 400 mm. Motors are 2/4 pole double polarity, tapped winding. Speed control for two speed motors is via switching or VSD (high speed only). Single speed motors can be controlled with VSD s Features Ventilation and smoke extraction in case of fire F300 (300 C/120 min.) Symmetrical blades; 100% reversible with low sound level IP55, insulation class H motors (smoke extract) Casing manufactured from galvanized steel Certified AS/NZS4429:1999. Dimensions Size HØ A B C D 315 420 1535 211 433 265 355 460 1695 211 473 305 400 500 1875 211 516 350 Performance E 223 243 266 F 425 465 505 Fan Model Thrust N Amps RPM kw kg Temp JAU31-H 22/6 1.95/0.4 2880/1440 0.8/0.16 60 300 C/2h JAU35-H 37/9 3.6/0.8 2880/1440 1.5/0.2 66 300 C/2h JAU40-H 55/14 3.6/0.8 2880/1440 1.5/0.2 68 300 C/2h Sound Fan Model JAU31-H JAU35-H JAU40-H db(a) @ 3m Sound Power Level db 63 125 250 500 1K 2K 4K 8K 57 78 71 85 70 69 64 64 58 58 76 79 86 72 68 66 65 61 59 81 81 86 75 69 69 65 63

JAU Axial hi temp series jet fans Discharge Patterns Resolvable air speed 2 m/s JAU40-H JAU35-H JAU31-H Resolvable air speed 4 m/s JAU40-H JAU35-H JAU31-H

JCC - Centrifugal Hi Temp Series jet fans Description JCC Series Jet Fans are centrifugal impeller types with smoke spill certification to AS/NZS4429:1999. The JC models are particularly useful where head clearances are restricted. Range Two models - 52N and 85N capacities. JCC25-H (52/14 Newton) JCC31-H (85/22 Newton) Features Ventilation and smoke extraction in case of fire F300 (300 C/120 min.) IP55, insulation class H motors (smoke extract) Certified AS/NZS4429:1999. Motors are two speed 4/8 pole asynchronous three phase types. Voltage / Frequency; 4015V/50 Hz. Smoke Spill Rating Smoke exhaust operation 300 C/120 (F300) certified AS/ NZS4429:1999. Construction Cases are formed from corrosion resistant galvanised sheet. Impellers are high efficiency backward curved types fabricated from galvanised steel sheet balanced according to ISO1940. Dimensions Model A B C D E F H I 6xØK JCC25-H 790 834 870 1248 285 370 185 210 13.5 JCC31-H 1140 1184 1220 1900 340 420 210 430 13.5 Performance Model Thrust N Amps RPM kw kg Temp JCC25-H 52 / 14 3.3/ 1.2 1430 / 715 1.3 / 0.22 78 300 C/2h JCC31-H 85 / 22 6.7 / 2.2 1425 / 715 3.7 / 0.7 164 300 C/2h Sound Fan Model db(a) @ Sound Power Level db 3m 63 125 250 500 1K 2K 4K 8K JCC25-H 66 77 90 86 87 77 79 76 67 JCC31-H 67 82 92 84 84 83 82 73 62

JCC- Centrifugal Hi Temp Series jet fans Discharge Patterns Resolvable air speed 13 m/s JCC31-H JCC25-H Resolvable air speed 8 m/s JCC31-H JCC25-H Resolvable air speed 5 m/s JCC31-H JCC25-H

JVC25 - EC jet centrif car park SPECIFICATIONS Description The JVC25 is an advanced EC jet impulse fan based on the technically superior ebm-papst RadiCal backward curved centrifugal impeller. The centrifugal wheel design delivers exceptional air efficiency with unmatched quietness. The low profile design is particularly useful where head clearances are restricted. The fans incorporate highly efficient permanent magnet EC motors with on board speed control and intelligent interface capability with BMS (management systems) or optional CO sensors. Motors Three phase permanent magnet, electronically commutated (EC) with long life ball type bearings Construction Cases are formed from corrosion resistant galvanised sheet with powder coat finish Technical Features Input for sensor 0-10 V or 4-20 ma External 24 V input (programming) Integrated PID controller RS485 MODBUS RTU Compatible Soft start Control input 0-10 VDC / PWM Over-temperature protected electronics / motor Dimensions Performance Air Flow Fan Model Thrust N Motor k/w Amps Air Speed m/s RPM kg m 3 /h JVC25 50 0.97 1.7 25 5,800 1550 85 Sound Sound Power Level db db(a) @ 3m 63 125 250 500 1K 2K 4K 8K 52 72 75 73 70 66 66 60 55